Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

38885919 complete overhauling of pressure parts of boiler, supply of scaffolding, jet cleaning of first and second pass of boiler, works of main boiler system, soot blower, drum internal, penthouse, repairing of seal plate of seal trough, repairing of buck stay, repairing / refixing / servicing of hangers and its supports, insulation, radiography test & other associated works required during oh#3, 2x210mw, btps, parichha, jhansi”. time duration: 30 days fy 2023 24 1 complete external water washing of all floors of boilerfrom 8 meter toroof of pent house and internal cleaning ofsecond pass including dust / ash disposal from pent house, dog house andeconomizer hopper. 2 supply and erection of cup lock in ist and 2nd pass scaffolding. total duration 30 days 3 high pressure jet cleaning for pressure part with supply of pump. 4 high pressure joints of carbon steel / low alloy t 11 / t 22 / t91 / tph 347 hp joints up to 76.1mm of tube size. 5 thickness survey ofboiler pressure part, 16 hanger economizer ( lower & upper bank ) / 16 hanger of ltsh and other area of boiler pressure part i.e. water wall, scw, crh, hrh, fsh, etc as per requirement. 6 unit rate of extra metal build up eroded portion of pressure parts tube caused by ash / steamerosion using suitable electrode matching with parent metal composition by arc and argon welding where joint is not required ( size:150mmlength x 35mmwidth, depth of erosion up to 2.5mm ) . 7 fin welding work of water wall / steam cool wall. 8 installation of ss shielding / cassette baffles in all erosion prone area like in screen water wall, ltsh, economiser and extended scw. 9 dp test of dissimilar joints of header tubes ( dp kit shall be in the scope of contractor ) . 10 repairing of skin casing of first pass & second pass of pent house and complete furnace sealing in pent house and dog house area. casting of refractory of penthouse where ever required after alignment / correction of roof sealing tubes. disposal of ash of penthouse. 11 repairing / replacement works of wind box expansion bellow and sadc of each corner. 12 overhauling of soot blower and aph blower. 13 complete overhauling of all lrsb, 1job= 6 nos. lrsb. 14 complete internal overhauling of boiler drum. 15 servicing of safety valves ( drum, super heater, hrh, crh and erv ) . 16 servicing of ms1 & ms2, economizer inlet valve, feed control valves and other various types of valves ( 250mm to 350mm size valve ) . 17 dismantling and casting of refractory work in various places inside boiler. 18 additional scaffolding / day due to delayof uprvunl end 19 repairing and reconditioning work of inspection window and man holes. 20 repairing of damaged / bulged seal plate of seal trough of boiler. 21 repairing and reconditioning of horizontal buck stay of ist and 2ndpass by cutting / dismantling / welding of buck stay link and resetting of horizontal buck stay link with buck stays. 22 repairing and reconditioning of vertical buck stay of first and second pass by cutting / dismantling / welding of buck stay link and resetting of vertical buck stay link with buck stays. 23 servicing / replacement / resetting of spring hangers, supports, anchor and restraints of critical piping and ducts and resetting the spring hangers on cold set values of boiler side 24 supply and fixing of 65mm thick lrb insulation pad in single layer 25 supply and fixing of 65 mm thick lrb insulation pad in double layer 26 supply and fixing of 65 mm thick lrb insulation pad in triple layer 27 supply and fixing of g.p. sheet 22 swg ( 0.71 mm thick ) 28 removing the old webbed g.c. sheet / g.p. sheet / aluminium sheet and fixing the same on lrb pads with self tapped screws. 29 lrb pads in 50mm applying with new aluminium sheet of 24 gauge on steam / feed lines 30 radiography of new h.p joints of boiler tube by remote operated gamma radiography camera, processing of films and interpretation of h.p joints during work in boiler. ( complete work of radiography, processing & submission of report of 01 no. h.p joint =01 no job ) 31 radiography of old h.p joints of boiler tube by remote operated gamma radiography camera, processing of films and interpretation of h.p joints during work in boiler ( complete work of radiography, processing & submission of report of 01 no. h.p joint =01 no job ) ...

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

36461086 procurement of hart protocol based fuji, yokogawa, rose mount make pressure transmitter for obra tps. , d.p. tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, drum level rnge 0 to 1200 mmwcl ( 540 to 660 mmwcl ) mx pr. 250 kg. / cm2 , d.p. tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, secondary air flow range 0 to 50 mmwcl mx pr. 160 kg.cm2 , d.p. tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy± 0.5 %, scanner fan furness dp range 0 to 500 mmwcl mx pr. 160 kg.cm2 , d.p. tx with manifold i / p supply 24 v dc, o / p 4 to 20 ma, accuracy± 0.5 %, wind box dp, range 0 to 150mmwcl mx. pr, 160 kg / cm2 , d.p. tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy± 0.5 %, pa flow to mill range 0 to 80 mmwcl. mx pr. 160 kg.cm2 , d.p. tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, bfp suction flow range 0 to 4000 mmwcl. mx pr. 160 kg.cm2 , d.p. tx with manifold i / p supply 24 v dc, o / p 4 to 20 ma, accuracy± 0.5 %, b / m dp, range 0 to 400 mmwcl. mx pr. 160 kg.cm2 , d.p. tx with manifold i / p supply 24 v dc, o / p 4 to 20 ma, accuracy ± 0.5 %, g.s.c. level tx. range 0 to 1050 mmwcl. mx pr. 160 kg / cm2 , pressure. tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, fg pressure at psh, range ( 50 ) to +50 mmwcl. mx pr. 160 kg.cm2 , pressure . tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, fg pressure at id i / l, range ( 400 ) to 0 mmwcl. mx pr. 160 kg / cm2 , pressure tx with manifold i / p supply 24 v dc, o / p 4 to 20 ma, accuracy ± 0.5 %, . fg pressure at id o / l, range ( 100 ) to 100 mmwclmx pr. 160 kg.cm2 , pressure . tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, .furnace pressure, range ( ) 250 to +250mmwcl mx pr. 160 kg.cm2 , pressure tx with manifold i / p supply 24 v dc, o / p 4 to 20 ma, accuracy ± 0.5 %, wind box pressure range 0 to 150 mmwcl. mx pr. 160 kg , pressure . tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, h2 gas pressure, range 0 to 2.0 kg / cm2 , feed water flow tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, range 0 to 6300 mmwcl. max pr. 250 kg. , pressure . tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, pr. at aph i / l range 0 to 1500 mmwcl. mx pr. 160 kg / cm2 , condencer vacuum transmitter with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, range ( ) 1 to 0 kg / cm2 mx pr. 160 kg , pressure .tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, condensor vacuum, range 0 to 760mmhg vacuum max pr. 160kg / cm2 , pressure .tx with manifold, model::2051cg3a02a1as5d404, cal.:0 to 760mmhgg ( vac. ) , supply:10.5 42.4vdc, o / p:4 to 20ma., serial no.:00444973, max. w.p.:36 psi / 2.48bar, accuracy ± 0.5 %, manifold p / n:c301121124 0000, mwp: 4640psi at 200deg.f, body:316ss. , 3 nos. ) ...

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

33692355 supply of hart protocol based fuji, yokogawa, rosemount make pressure transmitters supply of hart protocol based fuji, yokogawa, rosemount make pressure transmitters , pressure tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, for opdr range o to 2.5 kg / cm2 ( make hart protocol based fuji, yokogawa, rosemount ) , pressure tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, furnace pressure, range 250 to +250 mmwcl ( make hart protocol based fuji, yokogawa, rosemount ) , pressure tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, condenser vacuum transmitters range 0 to 760 mmhgcl ( make hart protocol based fuji, yokogawa, rosemount ) , drum pr / ms pr tx with manifold i / p supply 24 vdc, o / p 4 to 20 ma, accuracy ±0.5%, range 0 to 200 kg / cm2 max pr 250 kg ( make hart protocol based fuji, yokogawa, rosemount ) , pressure tx with manifold i / p supply 24v dc, o / p 4 to 20ma, accuracy ±0.5%, gland seal pr range 0.5 to +0.5kg / cm2 ( make hart protocol based fuji, yokogawa, rosemount ) , pressure tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, range 400 to +400 mmwcl ( make hart protocol based fuji, yokogawa, rosemount ) , pressure tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, cst tank level range 0 to 10000mmwcl ( make hart protocol based fuji, yokogawa, rosemount ) , pressure tx with manifold i / p supply 24v dc, o / p 4 to 20ma, accuracy ±0.5%, hydrogen pressure range 0 to 6 kg / cm2 ( make hart protocol based fuji, yokogawa, rosemount ) , pressure tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, prds prrange 0 to 30 kg / cm2 ( make hart protocol based fuji, yokogawa, rosemount ) , dp tx with manifold i / p supply 24v dc, o / p 4 to 20ma, accuracy ±0.5%, h & seal oil dp range 0 to 2 kg / cm2 ( make hart protocol based fuji, yokogawa, rosemount ) , pressure tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, fg pressurerange 0 to 30 kg / cm2 for lfo & hfo oil ( make hart protocol based fuji, yokogawa, rosemount ) , dp pressure tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, wind box pressure range 0 to 1000 mmwcl pa pr. of mil ( make hart protocol based fuji, yokogawa, rosemount ) , dp level tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, l.p. heater range 0 to 1600 mmwcl ( make hart protocol based fuji, yokogawa, rosemount ) , dp level tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, hp heater range 0 to 1000 mmwcl. max. pr. 160 kg ( make hart protocol based fuji, yokogawa, rosemount ) , dp level tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, cst tank level range 0 to 15000 mmwcl. max. pr. 160 kg ( make hart protocol based fuji, yokogawa, rosemount ) , dp tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, sh spray water flow l & r range 0 to 9000 mmwcl. max. pr. 250 kg ( make hart protocol based fuji, yokogawa, rosemount ) , dp tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, rh spray water flow l & r range 0 to 40500 mmwcl. max. pr. 250 kg ( make hart protocol based fuji, yokogawa, rosemount ) , flow tx with manifold i / p supply 24v dc, o / p 4 to 20 ma, accuracy ±0.5%, stator water flow range 0 to 2500 mmwcl. max. pr. 160 kg ( make hart protocol based fuji, yokogawa, rosemount ) , 3 nos. ) ...

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

33372997 mechanical maintenance of aph, esp, various ducts & dampers installed in bmd i, dtps, anpara along with external cleaning of boiler 2 opening of all the access doors of aph he &ce for inspection & execution of the work & closing them after completion of work byapplying hold it & replacing old asbestos rope with new one. 3 providing temporary scaffolding at he / ce for inspection & execution of works and removal of the same after completion of work. 4 servicing of lub oil system of guide / support bearing of aph. one job includes one lub oil system of guide / support bearing of aph. 5 servicing of rotor drive unit of aph. one job includes one drive of aph. 6 revisioning / replacement & resetting of he / ce inboard, interm & outboard radial seals of aph 7 revisioning / replacement & resetting of bypass seals of aph cold end 8 revisioning / replacement & resetting of bypass seals of aph hot end 9 revisioning / replacement & resetting of axial seals of aph hot end 10 revisioning / replacement & resetting of axial seals of aph cold end 11 revisioning / replacement & resetting of rotor post seals of aph hot end 12 revisioning / replacement & resetting of rotor post seals of aph cold end 13 repairing / replacement of seal ring segment of aph hot end 14 repairing / replacement of seal ring segment of aph cold end 15 repairing / replacement of static seal plate of aph hot end 16 repairing / replacement of static seal plate of aph cold end 17 servicing of air motor ofaph 18 alignment of rotor drive unit with electric / air motor of aph 19 servicing / repairing of single nozzle cleaning device & checking of its travel ofaph 20 cleaning of aph heating element in situ cond. with the help of water / air jet 21 replacement / repairing of eroded / damaged bracing pipes ofaph 22 repairing of expansion joints / strengthen of old welding of duct from flue gas / air inlet damper to flue gas / air outlet dampers of aph. 23 revisioning / repairing of air seal housing of aph 24 repairing of manholes of aph 25 repairing of eroded casing of aphs. 26 checking of fire fighting / water washing pipe & replacement / blanking of eroded nozzles of aph hot end. it also includes the removal of chocking of the pipe & patching over eroded portion. 27 checking of fire fighting / water washing pipe & replacement / blanking of eroded nozzles of aph cold end. it also includes the removal of chocking of the pipe & patching over eroded portion. 28 replacement of oil seals of the drive shaft of the rotor drive unit of aphs 29 removal of scrap material from ash hopper of aph 30 reclamation / repairing / conversion of worn out basket of aph.hot end & intermediate. 31 fabrication & erection of plate forms / structures for facilitating the various running and breakdown maintenance works of air pre heaters. 32 replacement / repairing / adjustment of adjuster bolt of axial seal plate / radial sector plate of aph 33 fixing of sealing bar & sealing strip over hot end baskets of aph 34 straightening & repairing of bent diaphragm of aph 35 replacement / repairing of eroded t bar of aph 36 servicing of gv / nrv / plate valve associated with aph and its auxiliaries 37 removal of choking of ash hoppers of aph 38 removal of ash accumulated over the space in between the rotor shell and aph outer body shell. 39 alignment of rotor level of aph 40 rectification of bulged / damaged rotor shell segment and alignment of pin rack of aph 41 servicing / replacement of gear box , counterweight & related accessories of single nozzle cleaning device of aph 42 servicing / replacement of lub oil pump of guide / support bearing of aph. 43 modification in air heater water washing line of aph ( he / ce ) / lube oil lines 44 replacement / repairing of damaged rotor angle / bypass angle of aph 45 replacement / repairing of fluid coupling of main drive motor and gear box of aph 46 servicing of gate and damper sealing blowers of pa / sa / flue gas including its duct 47 dismantling and lowering of aph hoist trolley from its position and after completion of work, lift it & assemble it to the same position. 48 water washing and cage repairing of aph basket which are taken out during o / h of unit 7 49 duct and dampers 50 servicing / revisioning ofprimary air / secondary air dampers before / after aph, scaph i / o damper and flue gas damper after aph. 51 maintenance of gates offlue gas inlet to aph, esp inlet and esp outlet 52 local operation of flue gas inlet gate, esp inlet / outlet gate. 53 fabrication offlue gas distribution flap to aph outlet 54 repairing / replacement of eroded flaps of flue gas, primary and secondary air dampers. 55 repairing / replacement of eroded stainless steel shafts of by plane dampers. 56 cleaning of aerofoil of secondary air duct to wind box 57 checking and repairing of s.s. coal nozzle tip, splitter plate of coal nozzle assbly. / air compartment assbly / oil compartment assbly. from inside the furnace ( in situ ) and application of refractory if found damaged at splitter plate. 58 inspection of boiler drum internals and rectification of defects observed. d.p. testing of shell joints to check for any crack and its repair by h.p. welding, when only 10 nos. turbo separators are taken out / replacement of manhole gasket and its tightening to ensure zero leakage. 59 servicing of spring hanger supports, hydraulic supports, anchors & restraints of boiler piping & ducts and resetting on cold set values. 60 repairing of flue gas / primary / secondary air ducts by providing m.s. / carbon steel plates over eroded portion and welding with suitable electrode. 61 repairing of metallic expansion joints before / after aph and wind box . 62 repairing of non metallic expansion jointsbefor and after esp. 63 welding of various ducts to arrest leakage of air / flue gas. 64 repairing / replacement of bracing of flue gas up to id fan inlet ad secondary air ducts from aph outlet to wind box. 65 servicing of scanner air fan. 66 fabrication and erection of temporary structures at different floors of 500 mw boilers 67 esp maintenance 68 cleaning of complete structure, electrodes, shock bar, rapping mechanism & hoppers from inside of esp of one field by wire brush, hard broom and old cloth. 69 removal of scrap, debris and ash from esp ash hoppers. 70 cleaning & removal of ash / dust from support insulator by fine cloth. 71 repairing of bent collecting electrodes in esp chamber in fix position. 72 removal of damaged emitting electrode and fixing the new emitting electrode. 73 servicing / repairing / replacement of rapping hammer in esp chamber. 74 repairing / replacement of shock bar by cutting huck bolts, removal from the collecting electrodes and re fixing the same on shock bar after repairing of shock bar its alignment to have equal gap on both sides in esp chamber. 75 repairing / re fixing of deflector plates on gas distribution screen. 76 repairing of eroded portion by welding in ash hopper, esp roof and other places inside and outside of the esp chamber. 77 repairing / re erection of new ash deflector plate as per size from m.s. plate of appropriate thickness with the help of gas cutting and welding. 78 inspection and checking of esp field and removal of minor defects. 79 replacement of asbestos rope of esp hopper manhole, casing manhole and top manhole 80 changing of damaged support insulator. 81 repairing of support insulator screen pipe inside the esp chamber. 82 alignment of disturbed emitting structure by opening all the cover plates of support structure. lifting the emitting structure about 50 mm after loosing all the nuts of the structure suspension rod and then restoring the cover plates and loosened nuts after alignment. 83 replacement of plane bearing of rapping mechanism. 84 repairing / replacement of shock bar guide ( front / rear ) and shock bar guide attachment by welding or grinding wherever required. 85 repairing / replacement of pin wheel of emitting electrode rapping mechanism. 86 fixing of” u” clamp / “u” guide by welding on collecting electrodes at appropriate places. 87 servicing / replacement of vertical shaft bearing of emitting electrodes raping mechanism & alignment of vertical shaft. 88 re fixing of „u? guide / „u? clamp by welding on collecting electrode plate. 89 changing of damaged shaft insulator. 90 cleaning and removal of ash / dust from shaft insulator by fine cloth. 91 repairing of bracings between esp inlet gate and gd screen and rear side of esp by providing patch at eroded area or changing new piece by bracing pipe as per size. 92 replacement / repairing of cerm shaft. 93 replacement / repairing of gdrm shaft. 94 replacement / repairing of eerm shaft. 95 repairing of emitting frame by patch welding. 96 fabrication / repairing of eerm manhole. 97 fabrication / repairing of casing manhole of esp. 98 repairing / replacement of shock pads. 99 replacement of primary / secondary screen of gdrm. 100 repairing / re fabrication of support of duct plate at esp inlet. 101 replacement of asbestos rope of esp shaft insulators cover. 102 replacement / re erection of damaged double gear boxes of motor of eerm. 103 replacement / re erection of damaged double gear boxes of motor of cerm / gdrm. 104 repairing of damaged rapping gear box. 105 servicing of rapping gear box coupling bearing block. 106 repairing of outer arms i. 107 repairing of outer arms ii for esp. 108 repairing of pin wheel arrangement –i of esp. 109 repairing of pin wheel arrangement –ii of esp. 110 repairing / reclamation of grip coupling of eerm of esp. 111 repairing of shaft insulators attachments of eerm of esp. 112 external cleaning of boiler unit no. 6 & 7 both 113 cleaning ofstairsand railingofboiler 0 meter to 9.35 meterfrom s1l s1r ( first raw of boiler column ) to s21l s21r 114 cleaning of complete boiler 9.35 to 18.65 meter floors from s1l s1r ( first raw of boiler column ) to s21l s21r including stairs , railing & interconnecting gallery from tg floor. 115 cleaning of complete boiler area ‘18.65 to 27.25’ meter floorsincluding interconnecting gallery from tg floor, stairs, railings , all oil skids & fuel oil ( hfo / ldo ) station. 116 cleaning of complete boiler area ‘27.25 to 36.7’ meter floors includingstairs, railings, interconnecting gallery from tg floor, all oil skids & fuel oil ( hfo / ldo ) station . 117 cleaning of complete boiler area ‘ 36.7 to 46.20’ meter floors including stairs, railings, all oil skids & fuel oil ( hfo / ldo ) station . 118 cleaning of complete boiler area ‘46.20 to 55.35’ meter floors including stairs, railings. 119 cleaning of complete boiler area ‘55.35 to 64.8’ meter floors including stairs, railings. 120 cleaning of complete boiler area ‘64.8 to 74.5’ meter floors including stairs, railings. 121 cleaning of complete boiler area ‘74.5 to 80.71’ meter floors including stairs, railings. 122 cleaning of 80 nos.of fuel inlet elbows & coal gates near burner blocks at 21.00 to 46.00 mtr 123 outside cleaning of ducts connecting aph outlet to wind box . 124 cleaning of various plate form , stairs, hand railings, structure for gas ducts connecting aph outlet to esp’s inlet. 125 cleaning of ducts connecting aph outlet to esp’s inlet and esp outlet to id fan inlet gate. 126 cleaning of rh / sh station, aph soot blowing staion & scaph station at various elevation. 127 cleaning of boiler soot blower station, cbd staion, & all ventstation at various elevation. 128 cleaning of one no. boiler during night ( 06 pm to 06 am ) of 2x500 m.w. 129 removal of ash from guide bearing area ofa.p.h. 130 cleaning of boiler inside sheeting, window glasses, drain pot & drain pipe and observation doors. 131 collection of garbage of boiler area and disposal of same at least 1 2 kmaway from chimney or area specified by engineer in charge...

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

30859518 overhauling of aph seal trough repairing of scaph system etc of unit 9 of 2x250 mw htps 1 complete overhauling of two nos. air pre heater of boiler of unit # 9 of 2x250mw. ( as per scope of work ) 2 replacement / reversal of he / ie du heating element baskets of aph for hot end & hot intermediate end. ( as per scope of work ) 3 repairing of scaph system of unit # 9 ( as per scope of work ) 4 inspection of hanger support 5 overhauling of all sadc damper ( air and coal ) 6 welding of sa / pa duct in wind box area 7 overhauling of seal trough. ( as per scope of work ) 8 overhauling of pa / sa scaph damper 9 overhauling of flue gas damper of aph 10 repairing work in different areas of boiler 11 optional work 12 replacement of guide bearing of aph. 13 replacement of support bearing of aph. 14 replacement of guide trunion of aph. 15 replacement / reversal of he / hi basket ( beyond 300 nos. ) . 16 repairing work in different areas of boiler ( beyond 60 sq. m. ) ....

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

28934638 supply of miscellaneous items of c and i for 200mw units. supply of miscellaneous items of c and i for 200mw units. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, drum level range 0 to 1200 mmwcl ( 540 to 660 mmwcl ) .make: fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, secondary air flow range 0 to 50 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, scanner fan furness dp range 0 to 500 mmwcl .make: fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, wind box dp, range 0 to 150mmwcl.make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, pa flow to mill range 0 to 80 mmwcl. make:fuji, yokagawa, rosemount or equivqlent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, bfp suction flow range 0 to 4000 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, b / m dp, range 0 to 400 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, g.s.c. level tx. range 0 to 1050 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, fg pressure at psh, range ( 50 ) to +50 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, fg pressure at id i / l, range : ( 400 ) to 0 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %. fg pressure at id o / l, range: ( 100 ) to 100 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, furnace pressure, range: ( ) 250 to +250mmwcl. make:fuji, yokagawa, rosemount or equivalent. , pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, wind box pressurerange 0 to 150 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, h2 gas pressure, range 0 to 2.0 kg / cm2. make:fuji, yokagawa, rosemount or equivalent. , feed water flow tx with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, range 0 to 6300 mmwcl. max pr. 250kg.make:fuji, yokagawa, rosemount or equivalent. , pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, pr. at aph i / l range0 to 1500 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , condencer vaccum transmiter with manifold i / p supply 24 v dc , o / p 4 to 20 ma, accuracy ± 0.5 %, range ( ) 1to 1500 kg / cm2. make:fuji, yokagawa, rosemount or equivalent. , pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, condensor vacuum, range 0 to 760mhg vacuum . make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, statot water flow. range:0 2500mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, main strean flow . range: 0 2500. make: fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, dearator level measurement. range:0 3540 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, re heater spray flow, range:0 40500mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, super heater spray flow. range:0 9000mmwcl. make:fuji, yokagawa, rosemount or equivqlent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, dp across fcv, range: 0 16 kg / cm2. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, cold pa header pr. range:0 1500mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, hot pa hdr pr. range:0 1200 mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, condensate flow, range:0 4000mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, hph level. range:0 1000mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, lp heater level, range: 760 840mmwcl. make:fuji, yokagawa, rosemount or equivalent. , differential pressure transmitters with manifold. i / p supply: 24 v dc , o / p: 4 to 20 ma, accuracy ± 0.5 %, dm makeup flow, range:0 2500mmwcl. make: fuji, yokagawa, rosemount or equivalent....

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

4758232 replacement of ss coal nozzle tips, cs coal nozzle, removal & cleaning & installation of oil & air nozzle ,overhauling and repairing of sadc worn out compensators of wind box, eroded surface of inner wall of wind box ans its ceiling etc. during overhauling of unit –i 2x110mw ptpp, parichha (jhansi)...

Indian Oil Corporation Limited - Uttar Pradesh

4040688 replacement of bank tubes for boilers 2 3 aph baskets for boilers 1 2 and replacement of hot air duct connection from aph to wind box for boilers 1 2 3 and associated jobs as per site requirement at tps area of mathura refinery ...

Indian Oil Corporation Limited - Uttar Pradesh

4035059 replacement of bank tubes for boilers #2, #3; aph baskets for boilers #1.#2 and replacement of hot air ductconnection from aph to wind box for boilers #1, #2, #3 and associated jobs as per site requirement at tps area of mathura refinery ...

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

2214025 cutting and removing of damage/worn out casing plate, replacement/repairing/ strengthening of wind box, flue gas secondary air ducts, cutting and removing of damage/ worn out buck stay, channels, angles, “t” iron and beams etc around main boiler, pent house....