East Central Railway - Uttar Pradesh

34773463 supply of supply, erection, testing & commissioning of vacuum interrupter suitable for similar to schneider make ht vcb panel ( model vg2 bw524 / 99 / ro, 00 2 kb020048 ) , make : schneider, l&t or similar.supply, erection, testing & commissioning of vacuum interrupter suitable for similar to schneider make ht vcb panel ( model vg2 bw524 / 99 / ro, 00 2 kb020048 ) , make : schneider, l&t or similar., supply, erection, testing & commissioning of vacuum interrupter suitable for similar to schneider make ht vcb panel ( model vg2 bw524 / 99 / ro, 00 2 kb020048 ) , make : schneider, l&t or similar. => limited...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

34655564 supply of ring type ct for protection / metering of vcb panels installed at various sub stations under edc fatehpur , 11 kv ring type c.t. / ratio 800 / 400 5a ( metering / protection burden 15 v.a. and metering accuracy 0.5 / protection accuracy 5 p 10 ) , 11 kv ring type c.t. / ratio 600 / 300 5a ( metering / protection burden 15 v.a. and metering accuracy 0.5 / protection accuracy 5 p 10 ) ...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

34381652 repairing of i / c and o / g vcb under edd deoband 2 repairing & setting of on and off tripping mechanism system together with adjustment of main shaft with replacementof sundary itam such as bus pin washer nut & bolt spring and wiring etc.eith complete cleaning and washing 3 remove of 11 kv vcb panel after disconnecting the connections. 4 instalationand fxing of vcb in panel making of connection with adjustment & proper energisation of vcb in perfect working order. 5 re setting of vaccume interrupter of vcb properly fittinig complete ( 03 sets ) 6 opening of 06 no. bushing rod and refitting the same after cleaning. 7 re setting of male and female fingger contact with cleaning etc. 8 cleaning of carbonized spout assembly bus ans cable box side by including cleaning of vcb panel and bus bar. 9 repairing andfitting of small and big graree from 11 kv vcb. 10 earthling of vcb incoming pannel of boring 60ft deep and fixing of 60ft gi pipe 1.5 inch dia class b and connecting with gi strip of size 40*5 mm at the botten of gi pipe to the t f with providing of required charcoal and salt in the pipe...

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

34338440 repairing and over hauling of 11 kv vcb ( incoming / outgoing panel installed at 33 / 11 kv sub stations in the area of electricity distribution division sandila, hardoi. complete repairing & overhauling 11 kv vcb panel ( incoming / outgoing feeders & repairing of defective damage parts spars electricals mechanical includingrepairing of relay & damage wiring.all cost of labour t&p will be provided by the contractor except vaccume interpreter....

Indian Oil Corporation Limited - Uttar Pradesh

34269627 supply of jyoti make vcb spares jyoti make vcb spares , list of item ( s ) / work ( s ) as per tender documents , closing coil assembly, 110v dc, 4vc49 110 , tripping coil assembly, 110v dc, 4vc49 106 , micro switch ( 1no+1nc ) , jyoti , bkr aux switch, vcb, 1250a, jyoti , mtr, spring charging, f / 6.6kvjyoti vcb , geared spring charge motor, 110v dc , 16 pin plug & socket , closing shaft with spring, ( 4vc49 0069 ) , tripping shaft with spring, ( 4vc49 0051 ) , spur gear assembly, ( 4vc49 0018 ) , jyoti , pinion gear assembly, ( 4vc49 0091 ) , jyoti , charging handle assembly ( 4vc49 0418 ) , trip catch assembly ( 4vc49 0244 ) , jyoti , closing catch assly. ( 4vc49 0150 ) , jyoti , tripcatch w / link assly, 3vc49 0008, jyoti , nut assembly ( 3vb79 073 ) , cam shaft assembly ( 3vc49 0004 ) , u shape barrier, vcb, 1250a, jyoti , crank ( lhs & rhs ) , wipe spring, p / n:4vc47 0194, jyoti , spring, closing, f / 12kv, jyoti vcb , spring, tripping, f / 12kv, jyoti vcb , brkr contct multiplier, 110v dc, 7no+7nc , switch, test posit, 2nc f / ht panel, jyoti , switch, l.r.control w / lock f / htpanel, jyot , tnc switch, 4 way, w / lock &key, 16a, 110vdc , vcb, vk10j25, 630a, 11kv , vcb vk 10m25a, 1250a, 220dc, 12 / 6.6kv, jyoti , vcb, vk10p25, 2000a, 11kv , vcb vk 10m40b, 1250a, c / s220dc, 12kv, jyoti , vacuum interrupter, vk10j25, jyoti , moulded contact shroud, 1vb79 0082 / 01 , coupling for 7.2kv, 3150a vcb , bus conductor upper ( 4vc13 0001 ) vk10j25 , bus conductor lower ( 4vc13 0004 ) vk10j25 , flexible jumper vk10j25, jyoti, 6.6kv , pds assembly, 27, 4vc19 0027 / 01 , insulating stud assy., 05, 3vc19 0007 / 05 , shutter assembly full ( 3vb79 0087 / 02 ) , pole, vacuum interrupter, p / n:10m25 , shrouds, 1250a, vcb, jyoti , coupling, jyoti vcb vk10m25a, 220dc, , busconductruper, jyoti vcb vk10m25a, 220dc , busconductrlowr, jyoti vcb vk10m25a, 220dc , flexible jumper, ( 3vc19 0009 ) , jyoti , pds assembly, 03, 4vc19 0027 / 03 , insul studassy, jyoti vcb vk10m25a, 220dc , vacuum intrupter for 7.2kv, 2ka vcb , moulded contact shroud, 1vb79 0009 / 03 , cplg, 4vc13 0104, f / vcb panel, 6.6kv, jy , upper bus conductor 7.2kv, 2kavcb , lower bus conductor 7.2kv, 2ka vcb , pds assembly, 28, 4vc19 0028 / 01 , insulating stud assy., 07, 3vc19 0007 / 07 , vacuum interrupter, vk10m40a, jyoti , contact, shroud, switchgear panel, jyothi , coupling, vk10m40a, vcb, jyoti, 4 vc 13 0011 , upr bs cond., vk10m40a, vcb, jyt, 4vc13 0002 , lwr bs cond., vk10m40a, vcb, jyt, 4vc13 0005 , flex jumper vcb vk10m40a, jyoti, 6.6kv , pds assly vk10m40a, jyoti, 6.6kv , insulating stud assly.vk10m40a & vk10j25 , vac.int toshiba, jyoti vcb vk10m40b, 220dc , mould cont shrd vcb vk10m40b, jyoti, 6.6kv , coupling jyoti vcb vk10m40b, 220dc , busconductruper, jyoti vcb vk10m40b, 220dc , busconductrlowr, jyoti vcb vk10m40b, 220dc , flex jumper vcb vk10m40b, jyoti, 6.6kv , pds assly vk10m40b, jyoti, 6.6kv , insulating stud assy., 01, 3vc19 0007 / 01 , shuter assy ful, jyoti vcb vk10m40b, 220dc...

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

34254220 remaining civil and electrical work of construction of 33 / 11 kv 2x10 mva gis based substation ghantaghar park, aminabad, lucknow on turnkey basis 1 33 / 11 kv power t / f 10 mva ( transformer provided by department ) 2 33 kv gis panel set scada compatible ( 2 i / c +1 b / c+1 b / r+2 o / g ) 3 11 kv vcb panel scada compatible ( 2 i / c+1 b / c+1 b / r+8 o / g ) 4 33kv l.a 5 33 kv xlpe cable 3x300 sq mm 6 33 kv i / door j / c kit 3x300 sq mm 7 33 kv o / door j / c kit 3x300 sq mm 8 11kv xlpe cable 3x300 sq mm 9 11kv 3x70 sq mm xlpe cable 10 11kv o / door c / j kit 3x300 sq mm 11 11 kv xlpe cable 3x185 sq mm 12 11 kv o / door c / j kit 3x185 sq mm 13 11 kv i / door c / j kit 3x185 sq mm 14 11kv i / door c / j kit 3x300 sq mm 15 11kv end termination c / j kit 3x70sq mm 16 11 / 0.4 kv t / f 63 kva 17 pvc cable 3.5x70 sqmm 18 24 volt battery set with battery charger 19 33kv line isolator 400 a 20 st pole 9 m long 21 cu. cable 6x2.5 sq mm 22 cu. cable 4x2.5 sq mm 23 cu. cable 2x2.5 sq mm 24 ms round bar 32 mm 25 fire extinguisher 26 fire bucket with stand 27 t&p items ( digital megger 11 kv, crimping tool, tongue tester, multi meter, tool box etc. ) 28 laying of single circuit 33 kv 3x300 sq mm xlpe cable in constructed trench and proper dressing. 29 laying of single circuit 11 kv 3x300 sq mm xlpe cable in constructed trench and proper dressing. 30 construction of t / f plinth of size 1.5x1.5x1.0 m on a padding 0.25m deep in ground 1:5:10 cemend sand and brick ballast on the top of padding brick work ist class brick of 0.95 mtr hight & 0.35 mtr wall will be constructed.rest wall should be 0.23 mtr thick.brick work in ratio 1:4 cement & cores sand in the hollow portion the sand should be fiilled from the ground level up to 15 centimeter below from the top of wall, cement, sand & brick ballasts should be filled up to 15 centimeter.two no. of channel 100x50 in length 1500mm will be grouded.0.35 cm.rcc will be done with cores sand, cement and stone ballast in the ratio of 1:2:4.the t / fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand. ( all the material will be arranged by the contractor . ) 31 laying of single circuit lt 3.5x70 sq mm xlpe cable in constructed trench and proper dressing. 32 s / c cable laying in normal soil by digging of trench 900 mm deep, 500 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. ( all thematerial required for laying will be supplied by thecontractor except 11 kv xlpe cable ) 33 s / c cable laying in constructed trench 34 cable laying in ms pipe 125 mm dia 35 cable laying in hdpe pipe 125 mm dia 36 isolator structure fabrication of isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per resspo drawing, with help of m.s channel 125x65 mm two pieces of m.s channel joined to each other by m.s flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. grouting of isolator structure in cc ( cement , coarse sand and stone grit of 20 mm gauge ) including supply of necessary t&p and painting os structure complete. ( all the material shall be arranged by contractor including rail piece ) 37 lightning arrestor structure : fabrication of lightning arrestor / ct structure / pt structureas per resspo drawing with the help of 2 nos m.s channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect. 38 cable stand with d.o arrangement fabrication and erection of cable support made of two pieces of m.s channel 100x50 mm, 4.0 mtr longjoined by 5 nosms flat 50x6 mm fixing of 6 nos 11 kv pin insulator with pin for do arrangement as per drawing and grouting in a block of size 300x300x700 mm complete with painting complete in all respect. 39 earthing by way of boring and lowering of b class gi pipe 50 mm dia from ground upto the water level ( minimum 30 meter deep ) as per standard 40 construction of cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover m.s strip at the interval of 0.30 m and m.s angle at both the edge of the trench and trench cover.iincluding trench cover in 0.5 m length with arrangement of hooks for lifting of cable trench cover in easy and safe manner. 41 fabrication of structures, grouting, plinthing and painting of structures for following equipment. 42 cable stand 43 neutral l bracket 44 providing and fixing of led light for yard lighting ( 8 nos ) 45 supply and fixing lt distribution panel for lighning of control room, switch yard and substation building the panel contaaining 1 no 63 amp mccb and 5 no outgoing mcbs for substaion buliding, yard lighting, ac and dc supply of panels etc. 46 hoisting of 33 kv single cable on existing / erected cable standincluding jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 47 hoisting of 33 kv single cable in 33 kvgis panelincluding jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 48 hoisting of 11kv single cable in 11 kv vcb panelincluding jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 49 hoisting of 11kv single cable outdoor end termination at including jumpering, dressing of cable with required all necessary clamps and nut, bolts pipe etc. ( all the material shall be arranged by contractor ) 50 construction of fire wall, rccframed with fire bricksin between transformers ( 4.5x0.345x4.00 ) mtr 51 price schedule for remaining work of construction of double story switch gear room building cum office and collection centre, boundary wall road drain culvert, tubewell & other associated worksas per annexure 1 52 supply of following auxiliary material 53 office table ( 1200x750x600 mm ) as per standard. 54 providing and fixing executivehigh back chair 55 armed chair 56 providing and fixing of visitor bench 3 seater 57 steel almirah 58 notice board as per norms 59 key board 60 load chart board 61 line chart board 62 s / s board 63 s / s board...

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

33974850 supply of electrical lighting, consumables and misc. items for jtpp supply of electrical lighting, consumables and misc. items for jtpp, malawan, etah , mccb 4 pole 100 amp , mcb 64 amp 4 pole , mcb box wih 04 no.mcb of 32 amp , street light of 90 watt led bulb with complete outdoor fitting , ctr 300 / 5 amp for stelmech make 11 kv panels , 4 sq.mm auto pvc copper wire of 90 m length , 2.5 sq.mm auto pvc copper wire of 90 m length , “d” spanner set dep 8x9 to 30x32make taparia / visko / bizi , ring spanner set 6x7mm to 30x32mm make taparia / visko / bizi , bihexagonal ½ inch squire drive socket set with extension bar 14 mm to 04 mm and t 20, t 25, t 30 &t 40make taparia / visko / bizi , screw driver set 4” to 12”make taparia / visko / bizi , meggar 2500v hand driven make waco / cie / meco , digital clampmeter tong tester 0 500 amp, & 0 600 voltsmake meco / fluke / htc , multimeter a / c / d / c make meco / fluke / htc , earthing line arrester rodisi standards make , phase separator, stelmec make 11kv vcb panelisi standards make , hrc fuse for dry type stelmec make 11 kv vcb panel isi standards make , auto copper pvc wire of 90 meter length, 04 sq.mm ( red, yellow, blue &black colour ) make –havells / polycab / finolex , led bulb 07w make philips / syska / havells , led bulb 09w make philips / syska / havells , street light with fitting 80w led bulb make philips / syska / havells , silica gelisi standards make , 3x300 sq.mm. xlpe cable end jointing kitmake raychem / denson / 3m , distilled water for batteriesisi standards make , h.t.tapeisi standards make , ctr ‘d’ type 300 / 150 / 5 a for stelmec make 11kv vcb panelsisi standards make , ctr ‘d’ type 200 / 100 / 5 a for stelmec make 11kvvcb panelsisi standards make , led bulb for 11kv stelmec make vcb for 11kv panelisi standards make , hrc fuse for 11kv / 110v pt dry type for stelmec vcbisi standards make , single phase, submersible pump starter, 2hpisi standards make , auxiliary contact male for dry type 11kv ptisi standards make , auxiliary contact female for dry type 11kv ptisi standards make , hrc fuse for 11kv dry type pt 3.15aisi standards make...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

33974807 supply of vaccume interrupter supply of vacuum interrupter suitable for different make 11 kv vcb ( panel ) installed at various 33 / 11 kv s / s. in the area of executive engineer, electricity distribution division i / ii / iv, mathura in the jurisdiction of superintending engineer, elect , supply of vaccume interrupter suitable for different make 11 kv vcb ( panel ) , abb , crompton greeves , stelmec , bhel...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

33816644 for supply of 60 nos. 11 kv incoming vcb panels and 100 nos 11 kv outgoing vcb panels for supply of 60 nos. 11 kv incoming vcb panels and 100 nos 11 kv outgoing vcb panels , 11 kv incoming vcb panels , 11 kv outgoing vcb panels....

North Central Railway - Uttar Pradesh

33551444 supply of jhansi workshop: replacement of old 11 kv ht ring main power cables, ht vcb panels, associated equipment and associated work in workshop jhansi.jhansi workshop: replacement of old 11 kv ht ring main power cables, ht vcb panels, associated equipment and associated work in workshop jhansi., ...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

33488328 development of distribution infrastructure of package prayagraj 2 at kaushambi, fatehpur, and pratapgarh district of puvvnluttar pradeshunderrevamped reforms based and results linked, distribution sector scheme 1 conversion of existing lt lines on bare conductor to areal bunch xlpe cable 2 conversion of existing lt lines with bare conductor to ab xlpe cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 3 supply of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 4 galvanized stay set for lt line with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, 1 no. stay guy insulator, nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 5 conversion of existing lt lines using new earthing as per approved drawings, technical specifications and scope of work 6 supply of spike earthing made of 20mm x 2500 mm gi solid rod 7 supply of 8 swg gi wire for earthing and guarding 8 supply of following lt ab xlpe cable for conversion of existing lt bare conductor line with ab xlpe cable as required as per technical specification, approved drawings and scope of work: 9 supply of aerial bunchedxlpe cable 3 x 50 sqmm+1x35 sqmm. ( bare messenger wire ) +1x16 sqmm. 10 supply of aerial bunchedxlpe cable 3 x 70 sqmm.+1x50 sqmm. ( bare messenger wire ) +1x16 sqmm. 11 supply of aerial bunchedxlpe cable 3 x 95 sqmm.+1x70 sqmm. ( bare messenger wire ) + 1x16 sqmm. 12 supply of aerial bunchedxlpe cable 3 x 120 sqmm. + 1x95 sqmm. ( bare messenger wire ) +1x16 sqmm. 13 supply of pole mounted lt distribution box as per approved drawings, technical specifications and scope of work 14 supply of three phase smc distribution box with clamps 15 supply of single phase smc distribution box with clamps 16 supply of xlpe insulated al. cable for energisation of distribution box / kiosk as per approved drawings, technical specifications and scope of work 17 suppply of 2cx25 sqmm stranded unarmoured xlpe cable ( al conductor ) for chargingsingle phase db 18 suppply of 4cx35sqmm stranded unarmoured xlpe cable ( al conductor ) for chargingthreephase db 19 supply of stone pad ( 300x300x75 ) 20 supply of accessories for ab xlpe cable as per approved drawings, technical specifications and scope of work 21 stainless steel strap 22 hdg lt pole clamp with nut & bolt for laying abc 23 dead end clamp with i hook ( insulated ) 24 suspension clamp with i hook ( insulated ) 25 95 / 35 sqmm 70 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 26 120 / 50 sqmm 95 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 27 lt insulation piercing connector 120 50 sqmm 50 25 sqmm size ( for energizing distribution box ) 28 lt insulation piercing connector 120 50 sqmm 120 50 sqmm size ( for line to line jumpering ) 29 lt insulation piercing connector 16 25sqmmsize suitable for street light connection 30 pre insulated compression connectors size 16 sqmm suitable for ab xlpe cable 31 pre insulated compression connectors size 50 sqmm suitable for ab xlpe cable 32 pre insulated compression connectors size 70 sqmm suitable for ab xlpe cable 33 pre insulated compression connectors size 95 sqmm suitable for ab xlpe cable 34 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 35 heat shrinkable type end cap for ab xlpe cable 36 supply of new 11 kv lines : feeder segregation ( agriculture feeder ) 37 supply of support for 11 kv overhead line as per technical specification, approved drawings and scope of work 38 supply of 8.5m / 180 kgs pcc poles ( pcc pole as per state practice ) 39 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 40 supply for 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms transformer base channel, ms flats pole extension channel with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 41 supply of hot dip galvanized ms nuts, bolts with washers turn buckle for guarding as per technical specification, approved drawings and scope of work. 42 supply of pole accessories as per technical specification, approved drawing and scope of work 43 supply of 11 kv danger board 44 supply of stone pad 300x300x75 45 supply of barbed gi wire 12 swg 46 supply of stay set ( galvanized ) with 50x8 mm stay clamp, stay guy insulator ( 1 nos. ) , anchor plate ( 200x200x6 ) , nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 47 supply of insulator and hardware as per technical specification, approved drawings and scope of work. 48 supply of 11 kv45 kn polymer disc insulator along with suitable hardware fittings 49 supply of 11 kv 5 kn polymer pin insulators 50 supply of earthing arrangement as per technical specifications, approved drawings and scope of work. 51 supply of spike earthing 20mm x 2500 mmgi solid rod 52 supply of 8 swg gi wire for earthing and guarding 53 supply of 6 swg gi wire for earthing and guarding 54 supply of acsr conductors of following sizes with jointing sleeves, binding materials, pg clamps, bi metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work 55 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 56 supply of 11 kv, 600a, 3 ph, 3 pin type, vertical mounting type, gang operated, ab switch along with support insulators, base channel down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 57 supply of 11 kv lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 58 supply for 11 kv lineunder ground railway crossing with 2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) using 150mm dia gi pipes ( grade a for underground laying and grade b for pole support ) , outdoor heat shrinkable cable jointing kit, 11 kv lightening arrestor station class 10ka ( 6 nos. ) , lugs, 4 nos gi 3 meters long pipe earthing, 6 swg gi wires, cable markers, bi metallick clamps and jumpering etc as required as per technical specifications, drawings and scope of the work. 59 supply of 11 lv line underground highway crossing ensuring statutory clearancesas required as per technical specification, approved drawings and scope of work 60 supply of 11 kv lineforunder ground highway crossing by 2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) using 160 mm hdpe pipe at road crossing and 150mm dia gi pipes ( gradeb for pole support ) , outdoor heat shrinkable cable jointing kits, 11 kv lightening arrestor station class 10ka ( 6 nos. ) , lugs, 4 nos gi 3 meters long pipe earthing, 6 swg gi wires, 7 / 20 gi wire, cable markers, bi metallick clamps and jumpering etc as required as per technical specifications, drawings and scope of the work. 61 supply of 12 kv 3ph indoor type switch gear and 11 kv xlpe cable as per technical specifications, approved drawings and scope of works: 62 supply of indoor type 12 kv 3 ph 1250 a vcb with control and protection system for out going feeder consisting ofct, a meter, volt meter, relays, energy meter ( tvm ) dlms compliant & accessories complete as per specifications for feeder breaker protection 63 11 kv 3x 185 sqmm xlpe armored power cable, aluminum stranded conductor, including their termination materials like indoor and outdoor termination kit, glands, lugs, tagging, cable path marker etc as required as per technical specifications, approved drawings and scope of the works. 64 supply for augmentation of lines 65 supply for augmentation of 33 kv line 66 supply for augmentation of 3 phase 33 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 67 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 68 supply new pre fabricated hot dip galvanized steel item, for augmentation of 33 kv line, like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 69 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 70 supply of pole accessories as per technical specification, approved drawing and scope of work 71 supply of 33 kv danger board 72 supply of gi barbed wire 12 swg 73 supply for augmentation of 3 phase 33 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material, aluminum tape and helical preformed fittings etc as required as per technical specification, approved drawings and scope of work. 74 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 75 supply of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 76 supply of 33 kv under ground cable as per technical specification, approved drawings and scope of work. 77 supply of 3cx300 sqmm 33 kv xlpe armored cable 78 supply of accessories for 33 kv3cx300 sqmm xlpe armored cable ( 2 nos including one spare ) like 160mm dia hdpe pipes for road crossing and 150 mm dia gi pipegrade b for pole support outdoor heat shrinkable cable jointing kits, lugs, cablepath markers, bi metallic clamps, and 7 / 20 gi wire as per technical specification, approved drawing and scope of work 79 supplyof new insulator and hardware for augmentation of33 kv line as per technical specification, approved drawings and scope of work 80 supply of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 81 supply of 33 kv 10 kn polymer pin insulators 82 supply of new earthing arrangement for augmentation of33 kv line as per technical specifications, approved drawings and scope of work. 83 8 swg gi coil 115 turns ( 1.85 kg ) 84 supply of new stay set ( galvanized ) for 33 kv line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate ( 300x300x8mm ) , nut bolts, 1 no. turn buckles, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 85 supply of new gi wire for earthing and guarding for augmentation of33 kv line as per technical specification, approved drawings and scope of work. 86 supply of 6 swg gi wire 87 supply of 8 swg gi wire 88 supply of conductor accessories as per technical specification, approved drawing and scope of work 89 supply of pg clamp for dog to dog conductor 90 supply of pg clamp for panther to panther conductor 91 supply for augmentation of 11 kv lines 92 supply for augmentation of 3 phase 11 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 93 supply of 8.5 meter long / 180 kg pcc poles ( pcc pole as per state practice ) 94 supply for augmentation of 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 95 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 96 supply of pole accessories as per technical specification, approved drawing and scope of work 97 supply of 11 kv danger board 98 stone pad ( 300x300x75mm ) 99 supply of gi barbed wire 12 swg 100 supply for augmentation of 3 phase 11 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. 101 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 102 supply of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 103 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 104 supply for augmentation of 3 phase 11 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 105 supply of 11 kv 45 kn polymer disc insulator along with suitable hardware fittings 106 supply of 11 kv 5 kn polymer pin insulators 107 supply for augmentation of 3 phase 11 kv line using new earthing arrangement as per technical specifications, approved drawings and scope of work. 108 supply of gi earthing spike made of 20x2500mm solid rod 109 supply for augmentation of 3 phase 11 kv line using new stay set ( galvanized ) with 50x8 mm stay clamp, guy insulator, anchor plate ( 200x200x6mm ) , nut bolts, 1 no turn buckles, 1.8 m long 16 mm diameter solid gi stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 110 supply for augmentation of 3 phase 11 kv line using new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 111 supply of 6 swg gi wire 112 supply of 8 swg gi wire 113 supply of conductor accessories as per technical specification, approved drawing and scope of work 114 supply of pg clamp for weasel to weasel conductor 115 supply of pg clamp for dog to dog conductor 116 supply of pg clamp for rabbit to rabbit conductor 117 installation of dt capacitor 118 supply of dt capacitor with fitting as per technical specification, approved drawing and scope of work 119 supply of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 120 supply of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 121 supply of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 122 supply of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 123 erection part 124 erection for conversion of existing lt lines on bare conductor to aerial bunch xlpe cable 125 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil of following pole as per scope of work, approved drawings and specifications: 126 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 127 erection of following types of poles for lt overhead line with stone pad, pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 128 erection of 8.5 m / 180 kgs pcc poles with base stone pad as required ( state practices of pcc pole and stone pad to be used ) 129 excavation of lt stay pit in following type of soils, as per scope of work, approved drawings and specifications: 130 normal soil 131 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 132 removal of existing lt bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched xlpe cable, fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, pre insulated compression connectors, 16 mm dia ms nuts & bolts, pole clamps, stainless steel strap, single and three phase pole mounted distribution board, energisation of distribution box through 2cx25 sqmm and 4cx35 sq.mm xlpe cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: 133 erection of aerial bunched xlpe cable3 x 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm 134 erection of aerial bunched xlpe cable 3 x 70 sqmm +1x50 sqmm ( bare messenger cum neutral ) +1x16 sqmm 135 erection of aerial bunched xlpe cable 3 x 95 sqmm +1x70 sqmm ( bare messenger cum neutral ) + 1x16 sqmm 136 erection of aerial bunched xlpe cable 3 x 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm 137 erection, testing & commissioning of earthing by inserting gi earthing spike made of 20mm solid rod as per approved drawings, scope of work and technical specifications 138 erection of 8 swg gi wire for earthing by providing gi nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications 139 erection, testing and commissioning of new 11 kv lines: feeder segregation ( agriculture feeder ) 140 survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of project manager 141 excavation of pole pit ( of depth 1 / 6th of pole length ) in normal soil for following type pole as per scope of work, approved drawings and specifications: 142 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 143 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 144 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , painting by red oxide & aluminum paint to stp poles including paint, numberingof poleby paint including cement concrete foundation using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 145 erection of 8.5 m / 180 kgs pcc poles with base pad including cement concreting, ( state practices of pcc pole, stone to be used ) 146 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.5 cmt + 0.014 cmt ( muffing ) 147 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washersas per technical specification, approved drawings and scope of work. 148 earthing arrangement as per technical specifications, approved drawings and scope of work. 149 erection, testing & commissioning of spike earthing 20mm x 2500mm solid rod 150 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 151 normal soil 152 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 1 nos. ) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 153 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 154 erection of 5 kn 11 kv polymer pin insulator 155 erection of 45 kn 11 kv polymer disc insulator with strain hardware 156 laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 157 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 158 erection, testing and commissioning of vertical type 11 kvab switch along with support insulators, base channel, down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 159 erection, testing & commissioning of 11 kv line for under ground railway crossing by2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) , using 150mm dia gi pipes, outdoor heat shrinkable cable jointing kits, lugs, 4 nosgi 3 meters long earthing pipe, 6 swg gi wires, cable markers, clamps, jumpering and 11 kv station type lightening arrestors ( 6 nos. ) , etc as required as per technical specifications, approved drawings and scope of he work. 160 erection, testing & commissioning of 11 kv line for under ground highway crossing by2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) , using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, 4 nosgi 3 meters long earthing pipe, 6 swg gi wires, 7 / 20 gi wire, cable markers, clamps, jumpering, 11 kv station type lightening arrestors ( 6 nos. ) , etc as required as per technical specifications, approved drawings and scope of he work. 161 erection of 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor typevacuum circuit breaker with adopter panel for out going feeder by leveling, alignment and welding on existing cable trench in control room. testing & commissioning of indoor vcb panel including 3 nos indoor type current transformer, a meter, volt meter, relay & accessories protection as per approved drawings, technical specifications and scope of the work.: 162 providing and fixing of sign board includingmaterial and its fabrication , painting , writing , logo and scheme name etc as per rdss guidelines and t.s 163 laying, erection, termination using indoor & outdoor termination kit, 11kv 3x 185 sqmm xlpearmored power cablesas per technical specifications, approved drawings and scope of works. : 164 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 165 erection of 6 swg gi wire 166 erection of 8 swg gi wire 167 extension of control room of 33 / 11 kv substation to accommodate vcb for new 11 kv feeders as per technical specification, approved drawing and scope of work. 168 design, engineering construction of control room building extension 300 sq feet including cost ofall materials, t&p and labour, etc. as per technical specification and approved drawing as per direction of employer 169 shifting of following distribution transformer along with fixture including dismantling , shifting and erection from one location to another location as per approved survey. 170 single phase transformer 171 three phase transformer 172 erection for augmentation of lines 173 erection for augmentation of 33 kv line 174 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 175 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 176 erection of following types of additional poles matching with existing line supports by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminum paint including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 177 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.5 cmt + 0.014 cmt ( muffing ) 178 excavation of stay pit for 33 kv stay in following type of soils, as per scope of work, approved drawings and specifications: 179 normal soil 180 erection of complete stay set with gi stay wire ( 7x4.00 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 181 erection, testing and commissioning of 33 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 182 erection of 33 kv 10 kn pin insulator with gi pin 183 erection of 33 kv 70 kn disc insulator with strain hardware ( set of 3, 11 kv disc insulators ) 184 erection, testing & commissioning of new pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. 185 dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store and laying out & stringing of new acsr conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. 186 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 187 stringing of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 188 erection, testing & commissioning of 33 kvunder ground cable by2 nos ( including one spare ) 3cx300 sqmm xlpe armored cable, using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering, etc as required as per technical specifications, approved drawings and scope of he work. 189 erection for augmentation of 3 phase 33 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 190 erection of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 191 erection of 33 kv 10 kn polymer pin insulators 192 erection, testing & commissioning of earthing as per technical specifications, approved drawings and scope of work. 193 8 swg gi coil 115 turns ( 1.85 kg ) 194 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 195 erection of 6 swg gi wire 196 erection of 8 swg gi wire 197 erection for augmentation of 11 kv lines 198 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 199 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 200 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 201 erection of 8.5 m / 180 kgs pcc poles withbase stone pad ( state practices of pcc pole and base plate / stone to be used ) 202 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 203 normal soil 204 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 205 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 206 erection of 11 kv pin insulator with gi pin 207 erection of 11 kv disc insulator with strain hardware 208 dismantling of existing overhead line conductor & fittings and depositing to employers store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 209 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 210 stringing of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 211 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 212 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and hdg ms nuts, bolts & washers as per technical specification, approved drawings and scope of work. 213 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 214 erection of 5 kn 11 kv polymer pin insulator 215 erection of 45 kn 11 kv polymer disc insulator with strain hardware 216 earthingand guarding arrangement as per technical specifications, approved drawings and scope of work. 217 erection, testing & commissioning of spike earthing 20mm solid rod 218 erection of 8 swg gi wire for earthing and guarding 219 erection of 6 swg gi wire for earthing and guarding 220 erection of dt capacitor 221 erection, testing & commissioning offollowing 440 volt lt shunt capacitor including mounting structure and accessories as required as per technical specifications, approved drawings and scope of work. 222 erection of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 223 erection of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 224 erection of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 225 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 226 discount offered in % 227 words final quoted price after discount...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

33488283 development of distribution infrastructure of packageprayagraj 1 at prayagraj district of puvvnluttar pradeshunderrevamped reforms based and results linked, distribution sector scheme 1 supply of consumer service cable 2 supply of armored service cable for consumer service connection with accessories as per technical specifications, scope of works and approved drawings 3 supply of single phase armored al cable size 2cx 6 sq mm 4 supply of three phase armored al cable size 4cx 16 sq mm 5 supply of 10 swg gi wire 6 supply of 8 swg gi wire 7 supply of gi pipe / m.s angle along with nails / clamps / proper binding e.t.c. as per rec std. 8 conversion of existing lt lines on bare conductor to areal bunch xlpe cable 9 conversion of existing lt lines with bare conductor to ab xlpe cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 10 supply of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 11 galvanized stay set for lt line with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, 1 no. stay guy insulator, nut bolts, 1 no. turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 12 conversion of existing lt lines using new earthing as per approved drawings, technical specifications and scope of work 13 supply of spike earthing made of 20mm x 2500 mm gi solid rod 14 supply of 8 swg gi wire for earthing and guarding 15 supply of following lt ab xlpe cable for conversion of existing lt bare conductor line with ab xlpe cable as required as per technical specification, approved drawings and scope of work: 16 supply of aerial bunchedxlpe cable 3 x 50 sqmm+1x35 sqmm. ( bare messenger wire ) +1x16 sqmm. 17 supply of aerial bunchedxlpe cable 3 x 70 sqmm.+1x50 sqmm. ( bare messenger wire ) +1x16 sqmm. 18 supply of aerial bunchedxlpe cable 3 x 95 sqmm.+1x70 sqmm. ( bare messenger wire ) + 1x16 sqmm. 19 supply of aerial bunchedxlpe cable 3 x 120 sqmm. + 1x95 sqmm. ( bare messenger wire ) +1x16 sqmm. 20 supply of pole mounted lt distribution box as per approved drawings, technical specifications and scope of work 21 supply of three phase smc distribution box with clamps 22 supply of single phase smc distribution box with clamps 23 supply of xlpe insulated al. cable for energisation of distribution box / kiosk as per approved drawings, technical specifications and scope of work 24 suppply of 2cx25 sqmm stranded unarmoured cable ( al conductor ) for chargingsingle phase db 25 suppply of 4cx35sqmm stranded unarmoured cable ( al conductor ) for chargingthreephase db 26 supply of stone pad ( 300x300x75 ) 27 supply of accessories for ab xlpe cable as per approved drawings, technical specifications and scope of work 28 stainless steel strap 29 hdg lt pole clamp with nut & bolt for laying abc 30 dead end clamp with i hook ( insulated ) 31 suspension clamp with i hook ( insulated ) 32 95 / 35 sqmm 70 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 33 120 / 50 sqmm 95 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 34 lt insulation piercing connector 120 50 sqmm 50 25 sqmm size ( for energizing distribution box ) 35 lt insulation piercing connector 120 50 sqmm 120 50 sqmm size ( for line to line jumpering ) 36 lt insulation piercing connector 16 25sqmmsize suitable for street light connection 37 pre insulated compression connectors size 16 sqmm suitable for ab xlpe cable 38 pre insulated compression connectors size 50 sqmm suitable for ab xlpe cable 39 pre insulated compression connectors size 70 sqmm suitable for ab xlpe cable 40 pre insulated compression connectors size 95 sqmm suitable for ab xlpe cable 41 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 42 heat shrinkable type end cap for ab xlpe cable 43 supply of new 11 kv lines : feeder segregation ( agriculture feeder ) 44 supply of support for 11 kv overhead line as per technical specification, approved drawings and scope of work 45 supply of 8.5m / 180 kgs pcc poles ( pcc pole as per state practice ) 46 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 47 supply for 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms transformer base channel, ms flats pole extension channel with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 48 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 49 supply of pole accessories as per technical specification, approved drawing and scope of work 50 supply of 11 kv danger board 51 supply of stone pad 300x300x75 52 supply of barbed gi wire 12 swg 53 supply of stay set ( galvanized ) with 50x8 mm stay clamp, stay guy insulator ( 1 nos. ) , anchor plate ( 200x200x6 ) , nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 54 supply of insulator and hardware as per technical specification, approved drawings and scope of work. 55 supply of 11 kv45 kn polymer disc insulator along with suitable hardware fittings 56 supply of 11 kv 5 kn polymer with pin insulators 57 supply of earthing arrangement as per technical specifications, approved drawings and scope of work. 58 supply of spike earthing 20mm x 2500 mm gi solidrod 59 supply of 8 swg gi wire for earthing and guarding 60 supply of 6 swg gi wire for earthing and guarding 61 supply of acsr conductors of following sizes with jointing sleeves, binding materials, pg clamps, bi metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work 62 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 63 supply of 11 kv, 600a, 3 ph, 3 pin type, vertical mounting type, gang operated, ab switch along with support insulators, base channel down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 64 supply of 11 kv lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 65 supply for 11 kv lineunder ground railway crossing with 2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) using 150mm dia gi pipes ( grade a for underground laying and grade b for pole support ) , outdoor heat shrinkable cable jointing kit, 11 kv lightening arrestor station class 10ka ( 6 nos. ) , lugs, 4 nos gi 3 meters long pipe earthing, 6 swg gi wires, cable markers, bi metallick clamps and jumpering etc as required as per technical specifications, drawings and scope of the work. 66 supply of 11 lv line underground highway crossing ensuring statutory clearancesas required as per technical specification, approved drawings and scope of work 67 supply of 11 kv lineforunder ground highway crossing by 2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) using 160 mm hdpe pipe at road crossing and 150mm dia gi pipes ( gradeb for pole support ) , outdoor heat shrinkable cable jointing kits, 11 kv lightening arrestor station class 10ka ( 6 nos. ) , lugs, 4 nos gi 3 meters long pipe earthing, 6 swg gi wires, 7 / 20 gi wire, cable markers, bi metallick clamps and jumpering etc as required as per technical specifications, drawings and scope of the work. 68 supply of 12 kv 3ph indoor type switch gear and 11 kv xlpe cable as per technical specifications, approved drawings and scope of works: 69 supply of indoor type 12 kv 3 ph 1250 a vcb with control and protection system for out going feeder consisting ofct, a meter, volt meter, relays, energy meter ( tvm ) dlms compliant & accessories complete as per specifications for feeder breaker 70 11 kv 3x 185 sqmm xlpe armored power cable, aluminum stranded conductor, including their termination materials like indoor and outdoor termination kit, glands, lugs, tagging, cable path marker etc as required as per technical specifications, approved drawings and scope of the works. 71 supply for augmentation of lines 72 supply for augmentation of 33 kv line 73 supply for augmentation of 3 phase 33 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 74 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 75 supply new pre fabricated hot dip galvanized steel item, for augmentation of 33 kv line, like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 76 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 77 supply of pole accessories as per technical specification, approved drawing and scope of work 78 supply of 33 kv danger board 79 supply of gi barbed wire 12 swg 80 supply for augmentation of 3 phase 33 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material, aluminum tape and helical preformed fittings etc as required as per technical specification, approved drawings and scope of work. 81 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 82 supply of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 83 supply of 33 kv under ground cable as per technical specification, approved drawings and scope of work. 84 supply of 3cx300 sqmm 33 kv xlpe armored cable 85 supply of 33 kv3cx300 sqmm xlpe armored cable ( 2 nos including one spare ) accessories like 160mm dia hdpe pipes for road crossing and 150 mm dia gi pipegrade b for pole support outdoor heat shrinkable cable jointing kits, lugs, cablepath markers, bi metallic clamps, 7 / 20 gi wire as per technical specification, approved drawing and scope of work 86 supplyof new insulator and hardware for augmentation of33 kv line as per technical specification, approved drawings and scope of work 87 supply of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 88 supply of 33 kv 10 kn polymer pin insulators 89 supply of new earthing arrangement for augmentation of33 kv line as per technical specifications, approved drawings and scope of work. 90 8 swg gi coil 115 turns ( 1.85 kg ) 91 supply of new stay set ( galvanized ) for 33 kv line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate ( 300x300x8mm ) , nut bolts, 1 no. turn buckles, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 92 supply of new gi wire for earthing and guarding for augmentation of33 kv line as per technical specification, approved drawings and scope of work. 93 supply of 6 swg gi wire 94 supply of 8 swg gi wire 95 supply of conductor accessories as per technical specification, approved drawing and scope of work 96 supply of pg clamp for dog to dog conductor 97 supply of pg clamp for panther to panther conductor 98 supply for augmentation of 11 kv lines 99 supply for augmentation of 3 phase 11 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 100 supply of 8.5 meter long / 180 kg pcc poles ( pcc pole as per state practice ) 101 supply for augmentation of 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 102 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 103 supply of pole accessories as per technical specification, approved drawing and scope of work 104 supply of 11 kv danger board 105 stone pad ( 300x300x75mm ) 106 supply of gi barbed wire 12 swg 107 supply for augmentation of 3 phase 11 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. 108 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 109 supply of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 110 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 111 supply for augmentation of 3 phase 11 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 112 supply of 11 kv 45 kn polymer disc insulator along with suitable hardware fittings 113 supply of 11 kv 5 kn polymer pin insulators 114 supply for augmentation of 3 phase 11 kv line using new earthing arrangement as per technical specifications, approved drawings and scope of work. 115 supply of gi earthing spike made of 20x2500mmsolid rod 116 supply for augmentation of 3 phase 11 kv line using new stay set ( galvanized ) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate ( 200x200x6mm ) , nut bolts, 1no. turn buckles, 1.8 m long 16 mm diameter solid gi stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 117 supply for augmentation of 3 phase 11 kv line using new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 118 supply of 6 swg gi wire 119 supply of 8 swg gi wire 120 supply of conductor accessories as per technical specification, approved drawing and scope of work 121 supply of pg clamp for weasel to weasel conductor 122 supply of pg clamp for dog to dog conductor 123 supply of pg clamp for rabbit to rabbit conductor 124 installation of dt capacitor 125 supply of dt capacitor with fitting as per technical specification, approved drawing and scope of work 126 supply of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 127 supply of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 128 supply of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 129 supply of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 130 supply of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 131 supply of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 132 erection part 133 installation of consumer service cable 134 installation of armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings 135 installation of single phase armored al cable size 2cx 6 sq mm 136 installation of three phase armored al cable size 4cx 16 sq mm 137 gi wire 8 swg 138 gi wire 10 swg 139 installation of gi pipe / m.s angle along with nails / clamps / proper binding e.t.c. as per r.e.c std. 140 erection for conversion of existing lt lines on bare conductor to aerial bunch xlpe cable 141 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil of following pole as per scope of work, approved drawings and specifications: 142 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 143 erection of following types of poles for lt overhead line with stone pad, pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 144 erection of 8.5 m / 180 kgs pcc poles with base stone pad as required ( state practices of pcc pole and stone pad to be used ) 145 excavation of lt stay pit in following type of soils, as per scope of work, approved drawings and specifications: 146 normal soil 147 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 1 no. ) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 148 removal of existing lt bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched xlpe cable, fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, pre insulated compression connectors, 16 mm dia ms nuts & bolts, pole clamps, stainless steel strap, single and three phase pole mounted distribution board, energisation of distribution box through 2cx25 sqmm and 4cx35 sq.mm xlpe cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: 149 erection of aerial bunched xlpe cable3 x 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm 150 erection of aerial bunched xlpe cable 3 x 70 sqmm +1x50 sqmm ( bare messenger cum neutral ) +1x16 sqmm 151 erection of aerial bunched xlpe cable 3 x 95 sqmm +1x70 sqmm ( bare messenger cum neutral ) + 1x16 sqmm 152 erection of aerial bunched xlpe cable 3 x 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm 153 erection, testing & commissioning of earthing by inserting gi earthing spike made of 20mm solid rod as per approved drawings, scope of work and technical specifications 154 erection of 8 swg gi wire for earthing by providing gi nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications 155 erection, testing and commissioning of new 11 kv lines: feeder segregation ( agriculture feeder ) 156 survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of project manager 157 excavation of pole pit ( of depth 1 / 6th of pole length ) in normal soil for following type pole as per scope of work, approved drawings and specifications: 158 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 159 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 160 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminum paint to stp poles including paint, numberingof poleby paint including cement concrete foundation using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 161 erection of 8.5 m / 180 kgs pcc poles with base pad including cement concreting, ( state practices of pcc pole, stone to be used ) 162 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.5 cmt + 0.014 cmt ( muffing ) 163 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washersas per technical specification, approved drawings and scope of work. 164 earthing arrangement as per technical specifications, approved drawings and scope of work. 165 erection, testing & commissioning of spike earthing 20mm x 2500mm gi solid rod 166 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 167 normal soil 168 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 169 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 170 erection of 5 kn 11 kv polymer with pin insulator 171 erection of 45 kn 11 kv polymer disc insulator with strain hardware 172 laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 173 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 174 erection, testing and commissioning of vertical type 11 kvab switch along with support insulators, base channel, down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 175 erection, testing & commissioning of 11 kv line for under ground railway crossing by2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) , using 150mm dia gi pipes, outdoor heat shrinkable cable jointing kits, lugs, 4 nosgi 3 meters long earthing pipe, 6 swg gi wires, cable markers, clamps, jumpering and 11 kv station type lightening arrestors ( 6 nos. ) , etc as required as per technical specifications, approved drawings and scope of he work. 176 erection, testing & commissioning of 11 kv line for under ground highway crossing by2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) , using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, 4 nosgi 3 meters long earthing pipe, 6 swg gi wires, 7 / 20 gi wire, cable markers, clamps, jumpering, 11 kv station type lightening arrestors ( 6 nos. ) , etc as required as per technical specifications, approved drawings and scope of he work. 177 erection of 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor typevacuum circuit breaker with adopter panel for out going feeder by leveling, alignment and welding on existing cable trench in control room. testing & commissioning of indoor vcb panel including 3 nos indoor type current transformer, a meter, volt meter, relay & accessories protection as per approved drawings, technical specifications and scope of the work.: 178 providing and fixing of sign board includingmaterial and its fabrication , painting , writing , logo and scheme etc as per rdss guidelines and t.s 179 laying, erection, termination using indoor & outdoor termination kit, 11kv 3x 185 sqmm xlpearmored power cablesas per technical specifications, approved drawings and scope of works. : 180 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 181 erection of 6 swg gi wire 182 erection of 8 swg gi wire 183 extension of control room of 33 / 11 kv substation to accommodate vcb for new 11 kv feeders as per technical specification, approved drawing and scope of work. 184 design, engineering construction of control room building extension 300 sq feet including cost ofall materials, t&p and labour, etc. as per technical specification and approved drawing as per direction of employer 185 shifting of following distribution transformer along with fixture including dismantling , shifting and erection from one location to another location as per approved survey. 186 single phase transformer 187 three phase transformer 188 erection for augmentation of lines 189 erection for augmentation of 33 kv line 190 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 191 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 192 erection of following types of additional poles matching with existing line supports by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminum paint including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 193 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.5 cmt + 0.014 cmt ( muffing ) 194 excavation of stay pit for 33 kv stay in following type of soils, as per scope of work, approved drawings and specifications: 195 normal soil 196 erection of complete stay set with gi stay wire ( 7x4.00 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 197 erection, testing and commissioning of 33 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 198 erection of 33 kv 10 kn pin insulator with gi pin 199 erection of 33 kv 70 kn disc insulator with strain hardware ( set of 3, 11 kv disc insulators ) 200 erection, testing & commissioning of new pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. 201 dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store and laying out & stringing of new acsr conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. 202 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 203 stringing of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 204 erection, testing & commissioning of 33 kvunder ground cable by2 nos ( including one spare ) 3cx300 sqmm xlpe armored cable, using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering, 7 / 20 gi wire etc as required as per technical specifications, approved drawings and scope of he work. 205 erection for augmentation of 3 phase 33 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 206 erection of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 207 erection of 33 kv 10 kn polymer pin insulators 208 erection, testing & commissioning of earthing as per technical specifications, approved drawings and scope of work. 209 8 swg gi coil 115 turns ( 1.85 kg ) 210 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 211 erection of 6 swg gi wire 212 erection of 8 swg gi wire 213 erection for augmentation of 11 kv lines 214 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 215 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 216 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 217 erection of 8.5 m / 180 kgs pcc poles withbase stone pad ( state practices of pcc pole and base plate / stone to be used ) 218 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 219 normal soil 220 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 221 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 222 erection of 11 kv pin insulator with gi pin 223 erection of 11 kv disc insulator with strain hardware 224 dismantling of existing overhead line conductor & fittings and depositing to employers store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 225 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 226 stringing of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 227 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 228 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and hdg ms nuts, bolts & washers as per technical specification, approved drawings and scope of work. 229 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 230 erection of 5 kn 11 kv polymer pin insulator 231 erection of 45 kn 11 kv polymer disc insulator with strain hardware 232 earthingand guarding arrangement as per technical specifications, approved drawings and scope of work. 233 erection, testing & commissioning of spike earthing 20mm solid rod 234 erection of 8 swg gi wire for earthing and guarding 235 erection of 6 swg gi wire for earthing and guarding 236 erection of dt capacitor 237 erection, testing & commissioning offollowing 440 volt lt shunt capacitor including mounting structure and accessories as required as per technical specifications, approved drawings and scope of work. 238 erection of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 239 erection of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 240 erection of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 241 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 242 erection of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 243 erection of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 244 discount offered in % 245 words final quoted price after discount...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

33392530 supply of vaccume interrupter suitable for different make 11 kv vcb (panel) installed at various 33 kv substation in the area of ee, eudd iii, mathura under the jurisdiction of se, eudc, mathura supply of vaccume interrupter suitable for different make 11 kv vcb (panel) installed at various 33 kv substation in the area of ee, eudd iii, mathura under the jurisdiction of se, eudc, mathura , supply of vaccume interrupter suitable for different make 11 kv vcb (panel) , abb , crompton greeves , stelmec , siemens , bhel , electroteknica switchgears , yamuna power...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

33392529 supply of vaccume interrupter suitable for different make 11 kv vcb (panel) installed at various 33 kv substation in the area of ee, eudd i, mathura under the jurisdiction of se, eudc, mathura supply of vaccume interrupter suitable for different make 11 kv vcb (panel) installed at various 33 kv substation in the area of ee, eudd i, mathura under the jurisdiction of se, eudc, mathura , supply of vaccume interrupter suitable for different make 11 kv vcb (panel) , abb , biecco , crompton greeves , stelmec...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

33392286 supply of vacuum interrupter suitable for different make 11 kv vcb ( panel ) installed at various 33 kv substation in the area of ee, eudd ii, mathura under the jurisdiction of se, eudc, mathura supply of vaccume interrupter suitable for different make 11 kv vcb ( panel ) installed at various 33 kv substation in the area of ee, eudd ii, mathura under the jurisdiction of se, eudc, mathura , supply of vaccume interrupter suitable for different make 11 kv vcb ( panel ) , abb , crompton greeves , stelmec , bhel , electroteknica switchgears , yamuna power , ece , pascal...

Kisan Sahkari Chini Mills Limited - Uttar Pradesh

33313436 supply and installation of transformer, mdi controller panel, servo 400kva and vaccum circuit breaker for new hydle connection supply and installation of transformer, mdi controller panel, servo 400kva and vaccum circuit breaker for new hydle connection , a vaccume circuit breaker ( vcb ) 630amp, cassette type closing & triping coil 230vac, spring charging, motor 220vac, l&t makeb complete vcb panel base mounted with required materials 1 current transformer100 / 5amp, dual core metering class 05, core 2 protection 03 nos. 2 potential transformer 100va, 11kv s / / 110vs3, fixed cl 0.5 01 nos.3 digital ammeter ( 0 100amp ) 01 nos4 digital voltmeter ( 0 11kv ) 01 nos. 5 protection relay overload, earth put 01 nos.6 indicating light r, y, b, on, off, trip, tch, sc 08 nos. 7 control mcb as required.8 selector switch ( local / remote ) 01 nos.9 push button emergency stop, mushroom head 01 nos.10 breaker control 16amp, 2nc 01 nos.11 auxiliary contractor 2no + 2nc 01 nos.12 hooter 01 nos. 13 panel illumination 01 nos. 14 space heater with thermostat 01 nos. , 1 mdi controller panel with incomer size 1575x800x800mm, indoor type base mounted with suitable paint. equipments details are given below which will fitted in above panel b mdo, acb mp based release o / c, s / c protection, 630amp, tp siemens, make 01 no b power contractor 500a, fp coid 415v ac, siemens make 01 no c mdi controller with programme 230v ac, 92x92 sqmm 01 no pentocon make d digital amp meter ) 0 600a ) , 96x96mm with ass 01 no e digital volt meter ( 0 600v ) , 96x96mm with vss 01 no f on delay timer 230v ac 01 no g r.y.b, phase indicator led type 230v ac 03 nos seimens make h on / off indicating lamp, led type 230 v ac 02 nos siemens make i auto / manual selector switch 01 nos j start / stop push button 02 nos k ba 10kasp, mcb for controlling siemens make 04 nos l 6ts for metering 600 / 5a, 15va, cl 1 tape wound 03 nos ae / kappa make , 2 transformer ( step down ) with testing certificate ( specifications ) a phase 3 b power 400kva c h.v. 11000 volt d l.v. 433 volt ± 1% e hv amp 21amp f lv amp 537 amp g frequency 50 h3 h level two i vector group dyn 11 j transformer oil appx 535 ltr k weight of transformer oil 455 kg l weightof core winding 50 kg m core material grain oriented electrical steel n cooling onan o ambient temp 45 degree c , 4a distribution panela 630amp main mccb, b 400amp mccb 02 nos.c 160amp mccb 02 no.d spare box for 400amp 01 no., e spare box for 160amp 01 no., f mccb alongwith busbar, led indicator, amp meter, volt meter etc. , 5 complete l t overhead line 250 mtr ( wire load capacity 1000amp ) ...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

33308199 vcb repairing under edsd iind, bijnor under 33 / 11 kv ss ganj, pilichoki, nangal jat, sikandri, kambhor, chowkpuri and jhalu. 1 complete repairing of tripping mechanism system and replacement of lever bush, spring etc for 11 kv vcb. 2 providing and replacement of tripping coil complete for 11 kv vcb. 3 providing and fixing of spout with copper contact suitable for 11 kv vcb. 4 providing and fixing damaged connecting rod complete for 11 kv vcb. 5 complete repairing of jack and replacement jack, bush, hearing and jack rod complete suitable for 11 kv vcb. 6 providing and fixing of jaw contact made of copper suitable for 11 kv vcb. 7 providing of 2.5 mm sq. pvc copper wire lugs etc and replacement of damaged burnt wiring complete of 11 kv vcb. 8 providing and fixing of metering and protection c.t. ratio 300 / 150 / 5 amp. suitable for 11 kv vcb. 9 complete overhauling and wiring with proper connection & proving and fixing of missing nut & bolt and proper panelfunctioned of 11 kv vcb. 10 complete overhauling and wiring with proper connection & proving and fixing of missing nut & bolt and proper functioned of 33 kv vcb panel control incoming and outgoing...

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

33292928 repairing, over hauling, testing and wiring & its associated work of 11 kv vcb panels installed at 33 / 11 kv sub stations in the area of electricity distribution sub division sandi road ( rural ) , hardoi....

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

33151785 jal jivan mision electrification work with material 2 st poles, 11meter long sp 55 3 11 kv v type x arm withclamp & nut and bolts 4 11 kv pin polymer insulator 45kn 5 acsr weasel conductor 6 m.s channel, 100x50x1300 mm for t off with clamp & nuts and bolts 7 stay complete 8 earthing complete 9 g.i wire for guarding @ 22 kg per pole 10 gaurding angle ( ms angle 65x65x6 / 1.6 meter ) with clamps & nut and bolts 11 11 kv polymer disc insulatort&c type 45kn 12 m.s channel, 100x50x2240 mm ( top channel ) with clamps & nuts and bolts 13 cross braseing ms angle with clamps & nuts and bolts 14 droper channel m.s. 100x50x2000 mm with clamps nuts & bolts 15 11 kv xlpe cable size 3x120mm2 16 i / d & o / d cable jointing kit suitable for 3x120 mm2 xlpe cable 17 gi pipe 6 dia 18 11 kv vcb o / g, 200 / 100 / 5a, ( steel makevcb ) , 250 mva 19 ms angle 75x75x6x2080 mm with clamp & bolt and nut ( s / s base ) 20 11kv tpmo swich with fixing clamp 21 chemical earthing complete for indor equipments 22 stone pad, 300x300x75 mm 23 f bracket with bolts & nuts 24 danger board with clamps nuts and bolts 25 barbed wire gi 26 pg clamps with nut & bolt 27 nut bolt with washer 28 work of following materials as per respo / puvvnl norms at the work site. 29 erection of single support st pole for construction of 11 kv line including digging of pit, fitting of all accessories, back filling of earth & others required work. 30 grouting of pole with 1:4:8 ratio of cement sand & brick ballast as per resspo norms. 31 erection & grouting of stay sets including digging of pit with 1:4:8 ratio of cement sand & brick ballast as per resspo norms, fixing binding and nuzzling of stay wire. 32 earthing of poles 33 stringing & sagging of 3 phase 11 kv line upto proper sag including laying of acsr weasel conductor, binding with insulators & jumpering. 34 erection of sectional double pole structure of stpole including digging of pit, fitting of accessories, back filling of earth, grouting of each pole 1:4:8 ratio of cement sand & brick ballast as per resspo norms, & stay sets & other required works. 35 drill / cut of stone for erection of pole / stay in hilly area 36 gaurding of 11 kv line as per respo norms 37 installation of 11 kv pilfer proof metering cubicle inside meter room, by fixing rag bolts after checking alignment with trench & conneting incomming & outgoing cable in the ct chamber 38 mounting of ct / pt unit on double pole with using 02 no. s / s base ( m.s. angle ) . 39 hanging of 11 kv 120 sqmm. xlpe cable after drawing stay wire between support with help of turn buckle. cable, will rest on hooks built of g.i. wire, proper fastening of cable, complete work. 40 11 kv 3x120 sq mm xlpe cable laying digging of trench size 0.75x0.75 mtr & putting layer of sand of bottam & laying of cable covering the trench from sites & top by laying bricks finely cover the same by earth. 41 11 kv 3x120 sq mm xlpe cable laying of 11 kv xlpe cable under g.i. pipe 6 dia by catting pucca / bitumen road & road restoration 42 making ofjointing kit of cable box size 3x120 mm2 11 kv indoor & outdoor type 43 construction of plinth, foundation & installation of 11 kv vcb 200 / 100 / 5a 44 chemical earthing complete of indoor structure vcb panel & pilfer cubicle etc....

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

33151773 jal jivan mision electrification work with material 2 st poles, 11meter long sp 55 3 11 kv v type x arm withclamp & nut and bolts 4 11 kv pin polymer insulator 45kn 5 acsr weasel conductor 6 m.s channel, 100x50x1300 mm for t off with clamp & nuts and bolts 7 stay complete 8 earthing complete 9 g.i wire for guarding @ 22 kg per pole 10 gaurding angle ( ms angle 65x65x6 / 1.6 meter ) with clamps & nut and bolts 11 11 kv polymer disc insulatort&c type 45kn 12 m.s channel, 100x50x2240 mm ( top channel ) with clamps & nuts and bolts 13 cross braseing ms angle with clamps & nuts and bolts 14 droper channel m.s. 100x50x2000 mm with clamps nuts & bolts 15 11 kv xlpe cable size 3x120mm2 16 i / d & o / d cable jointing kit suitable for 3x120 mm2 xlpe cable 17 gi pipe 6 dia 18 11 kv vcb o / g, 200 / 100 / 5a, ( steel makevcb ) , 250mva 19 ms angle 75x75x6x2080 mm with clamp & bolt and nut ( s / s base ) 20 11kv tpmo swich with fixing clamp 21 chemical earthing complete for indor equipments 22 stone pad, 300x300x75 mm 23 f bracket with bolts & nuts 24 danger board with clamps nuts and bolts 25 barbed wire gi 26 pg clamps with nut & bolt 27 nut bolt with washer 28 work of following materials as per respo / puvvnl norms at the work site. 29 erection of single support st pole for construction of 11 kv line including digging of pit, fitting of all accessories, back filling of earth & others required work. 30 grouting of pole with 1:4:8 ratio of cement sand & brick ballast as per respo norms. 31 erection & grouting of stay sets including digging of pit with 1:4:8 ratio of cement sand & brick ballast as per respo norms, fixing binding and nuzzling of stay wire. 32 earthing of poles 33 stringing & sagging of 3 phase 11 kv line upto proper sag including laying of acsr weasel conductor, binding with insulators & jumpering. 34 erection of sectional double pole structure of stpole including digging of pit, fitting of accessories, back filling of earth, grouting of each pole 1:4:8 ratio of cement sand & brick ballast as per respo norms, & stay sets & other required works. 35 drill / cut of stone for erection of pole / stay in hilly area 36 gaurding of 11 kv line as per respo norms 37 installation of 11 kv pilfer proof metering cubicle inside meter room, by fixing rag bolts after checking alignment with trench & conneting incomming & outgoing cable in the ct chamber 38 mounting of ct / pt unit on double pole with using 02 no. s / s base ( m.s. angle ) . 39 hanging of 11 kv 120 sqmm. xlpe cable after drawing stay wire between support with help of turn buckle. cable, will rest on hooks built of g.i. wire, proper fastening of cable, complete work. 40 11 kv 3x120 sq mm xlpe cable laying digging of trench size 0.75x0.75 mtr & putting layer of sand of bottam & laying of cable covering the trench from sites & top by laying bricks finely cover the same by earth. 41 11 kv 3x120 sq mm xlpe cable laying of 11 kv xlpe cable under g.i. pipe 6 dia by catting pucca / bitumen road & road restoration 42 filling of cable box size 3x120 mm2 11 kv indoor & outdoor type 43 construction of plinth & foundation of 11 kv vcb as per respo norms. 44 chemical earthing complete of indoor structure vcb panel & sub station 45 supply of following materials as per resspo / puvvnl norms at the work site. 46 10 mva t / f, 33 / 11 kv 47 33 kv vcb with single t / f control pannel and ct 200 / 100 / 1a with structure ( i ) 33 kv vcb ( ii ) control panel i / c for 33 kv single t / f ( iii ) ct 200 / 100 / 1 1a ( iv ) steel structure 48 11 kv 3x300 sq. mm xlpe cable 49 acsr dog conductor 50 control cable 2x2.5 mm sq. 51 control cable 4x2.5 mm sq. 52 power t / f ht bushing connector 53 power t / f lt bushing connector 54 11 kv cable jointing kit 3x300 sq.mm i / d 55 11 kv cable jointing kit 3x300 sq.mm o / d 56 33 kv post insulator 57 earthing of indoor equipment 58 33 kv lightening arrestor 59 errection of followimg materialsat 33 / 11 kv s / s pannuganj. 60 dismentling of old 5 mva t / f from plinth and all connetions and errection of new 10 mva t / f on plinth with all assesries and connctions. 61 plinth and foundation for 33 kv vcb 62 contol pannel i / c for 33 kv singlet / f 63 laying of control cable 2x2.5sq mm & 4x2.5sq mm 64 errection steel structure 65 cable laying of 3x300 mm sq. with brick & sand 66 errection of 33 kv lightening arrestor 67 errection of 33 kv post insulator...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32981772 tender for 33 / 11 kv chora and kuakheda, on damage 11 kv incoming and outgoing vcb panel repair work 2 complete reparing of tripping mechanism system and replacement of lever bush, sping etc.of 11 kv vcb. 3 providing and fixing of damage tripping coil complete of 11 kv vcb. 4 providing and fixing of charging gerari & non retun bearingof 11 kv vcb. 5 providing and fixing of epoxy spout complete with copper contact suitable for 11 kv vcb. 6 providing and fixing of female contact & 03 no. brass bush etc suitable for 11 kv vcb. 7 complete reparing of jack and replacement of lever, bush, bearing and jack rod complete suitable for 11 kv vcb. 8 providing of 2.5 mm sq pvc copper wire lugs etc and replacement of damaged burnt wiring complete of 11 kv vcb. 9 providing and fixing of jaw contact make of copper suitable for 11 kv vcb. 10 providing and fixing of intraptor connecting rod of11 kv vcb. 11 complete overhauling prpoer connection & providing and fixing of missing nut & bolts and proper functioning of 11 kv vcb....

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

32864707 51/edc(h)/2022 23 51/edc(h)/2022 23 , supply of vacuum interrupter suitable for different make vcb (panel) (i/c & o/g) as per sample. , stelmec make , crompton make , yamuna make , paskal make , beeco make , semens make...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32835781 vcb repairing under edsd iind, bijnor under 33 / 11 kv ss ganj, pilichoki, nangal jat, sikandri, kambhor, chowkpuri and jhalu. 1 complete repairing of tripping mechanism system and replacement of lever bush, spring etc for 11 kv vcb. 2 providing and replacement of tripping coil complete for 11 kv vcb. 3 providing and fixing of spout with copper contact suitable for 11 kv vcb. 4 providing and fixing damaged connecting rod complete for 11 kv vcb. 5 complete repairing of jack and replacement jack, bush, hearing and jack rod complete suitable for 11 kv vcb. 6 providing and fixing of jaw contact made of copper suitable for 11 kv vcb. 7 providing of 2.5 mm sq. pvc copper wire lugs etc and replacement of damaged burnt wiring complete of 11 kv vcb. 8 providing and fixing of metering and protection c.t. ratio 300 / 150 / 5 amp. suitable for 11 kv vcb. 9 complete overhauling and wiring with proper connection & proving and fixing of missing nut & bolt and proper panelfunctioned of 11 kv vcb. 10 complete overhauling and wiring with proper connection & proving and fixing of missing nut & bolt and proper functioned of 33 kv vcb panel control incoming and outgoing...

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

32804255 supply of materials under etd, bahraich supply of materials under etd, bahraich , pts having 11kv/110v with housing suitable for gtl make incomer vcb indoor type, core1 & 2 50va, class 0.5 for metering, class 3p for protection. , pts having 11kv/110v with housing suitable for stelmec make incomer vcb indoor type, core1 & 2 50va, class 0.5 for metering, class 3p for protection , pts having 11kv/110v with housing suitable for coronet make incomer vcb indoor type, core1&2 50va ,class 0.5 for metering, class 3p for protection , auxilary contact switch 8 no+ nc , tnc switch for stelmac make vcb panel size 96x96 , 86x relay salzar/pla make/ mkp 2c/o, 30amp., 24v dc , 86x relay salzar/pla make/ mkp 3c/o, 30amp., 24v dc , antipumping device 24 40 v dc dc coil inventa make , multistanderd copper wire, 2.5 sqmm for 1100v grade pvc insulation red in colour , multistanderd copper wire, 2.5 sqmm for 1100v grade pvc insulation yellow in colour , multistanderd copper wire, 2.5 sqmm for 1100v grade pvc insulation blue in colour , multistanderd copper wire, 2.5 sqmm for 1100v grade pvc insulation black in colour , lugs for 2.5 sqmm copper wire for u type , lugs for 2.5 sqmm copper wire for pin type , lugs for 2.5 sqmm copper wire for d type , lugs for 2.5 sqmm copper wire for fdd type , mcb 16a 230 v ac double pole , godrej nav tal lock 8 lever , m seal , digital clamp meter motwanedcm , crimping tool , cts having ratio 400/300/sa,15va suitable for cgl make 11 kv outgoing vcb indoor type , cts having ratio 200/300/sa,15va suitable for cgl make 11 kv outgoing vcb indoor type , cts having ratio 600/300/sa, core1 15va, cl 5p10 for protection, core2 2.5va, cl 0.5 for metering, suitable for stelmec make 11 kv outgoing vcb indoor type , cts having ratio 300/150/sa, core1 15va cl 5p10 for protection, core 2 2.5va, cl 0.5 for metering, suitable for stelmec make 11 kv outgoing vcb indoor type , cts having ratio 600/200/sa, 15va suitable for toshiba make 11 kv outgoing vcb indoor type , cts having ratio 300/150/sa, 15va suitable for pascal make 11 kv outgoing vcb indoor type , cts having ratio 1200/600/sa, 15va suitable for pascal make 11 kv outgoing vcb indoor type , cts having ratio 600/300/sa, 15va suitable for pascal make 11 kv outgoing vcb indoor type , cts having ratio 600/300/sa, 15va suitable for coronet make 11 kv outgoing vcb indoor type , cts having ratio 300/150/sa, 15va suitable for coronet make 11 kv outgoing vcb indoor type...

Kisan Sahkari Chini Mills Limited - Uttar Pradesh

32678968 supply and installation of transformer, mdi controller panel, servo 400kva and vaccum circuit breaker for new hydle connection supply and installation of transformer, mdi controller panel, servo 400kva and vaccum circuit breaker for new hydle connection , a vaccume circuit breaker ( vcb ) 630amp, cassette type closing & triping coil 230vac, spring charging, motor 220vac, l&t makeb complete vcb panel base mounted with required materials 1 current transformer100 / 5amp, dual core metering class 05, core 2 protection 03 nos. 2 potential transformer 100va, 11kv s / / 110vs3, fixed cl 0.5 01 nos.3 digital ammeter ( 0 100amp ) 01 nos4 digital voltmeter ( 0 11kv ) 01 nos. 5 protection relay overload, earth put 01 nos.6 indicating light r, y, b, on, off, trip, tch, sc 08 nos. 7 control mcb as required.8 selector switch ( local / remote ) 01 nos.9 push button emergency stop, mushroom head 01 nos.10 breaker control 16amp, 2nc 01 nos.11 auxiliary contractor 2no + 2nc 01 nos.12 hooter 01 nos. 13 panel illumination 01 nos. 14 space heater with thermostat 01 nos. , 1 mdi controller panel with incomer size 1575x800x800mm, indoor type base mounted with suitable paint. equipments details are given below which will fitted in above panel b mdo, acb mp based release o / c, s / c protection, 630amp, tp siemens, make 01 no b power contractor 500a, fp coid 415v ac, siemens make 01 no c mdi controller with programme 230v ac, 92x92 sqmm 01 no pentocon make d digital amp meter ) 0 600a ) , 96x96mm with ass 01 no e digital volt meter ( 0 600v ) , 96x96mm with vss 01 no f on delay timer 230v ac 01 no g r.y.b, phase indicator led type 230v ac 03 nos seimens make h on / off indicating lamp, led type 230 v ac 02 nos siemens make i auto / manual selector switch 01 nos j start / stop push button 02 nos k ba 10kasp, mcb for controlling siemens make 04 nos l 6ts for metering 600 / 5a, 15va, cl 1 tape wound 03 nos ae / kappa make , 2 transformer ( step down ) with testing certificate ( specifications ) a phase 3 b power 400kva c h.v. 11000 volt d l.v. 433 volt ± 1% e hv amp 21amp f lv amp 537 amp g frequency 50 h3 h level two i vector group dyn 11 j transformer oil appx 535 ltr k weight of transformer oil 455 kg l weightof core winding 50 kg m core material grain oriented electrical steel n cooling onan o ambient temp 45 degree c , 3 servo voltage stabilizer 400 kva linear type with range 340 440 volt , 4a apfc automatic panel with oil field shd capaciter a main acb 630 amp pole b busbar, c indicating light r, y, b, on, off, trip, tch, sc, d amp meter, volt meter, e auto manual selector switch4b distribution panela 630amp main acb, b 400amp mccb 03 nos.c 200amp mccb 01 no.d spare box for 200amp 01 no., e mccb alongwith busbar, led indicator, amp meter, volt meter etc.f automatic changeover 630amp 02 nos., g 200amp 01 no. , 5 complete l t overhead line 250 mtr ( wire load capacity 1000amp ) ...

Uttar Pradesh Jal Nigam - Uttar Pradesh

32666562 restoration and renovation of 36 kv ht incomer vcb panel 01 no and outgoing panel 02 nos power control wiring closing and opening mechanism at 100 cusec ganga jal wtp siddharatha vihar ghaziabad...