Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37729452 tender for vcb repairing work under edd deoband 2 repairing & setting of on and off tripping mechanism system together with adjustment of main shaft with replacementof sundary itam such as bus pin washer nut & bolt spring and wiring etc.eith complete cleaning and washing 3 remove of 11 kv vcb panel after disconnecting the connections. 4 instalationand fxing of vcb in panel making of connection with adjustment & proper energisation of vcb in perfect working order. 5 re setting of vaccume interrupter of vcb properly fittinig complete ( 03 sets ) 6 opening of 06 no. bushing rod and refitting the same after cleaning. 7 re setting of male and female fingger contact with cleaning etc. 8 cleaning of carbonized spout assembly bus ans cable box side by including cleaning of vcb panel and bus bar. 9 repairing andfitting of small and big graree from 11 kv vcb. 10 repairing and fitting of baring and charging rod from 11 kv vcb....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37729422 for supply of 16 nos. 11 kv incoming vcb panels and 65 nos. 11 kv outgoing vcb panels for supply of 16 nos. 11 kv incoming vcb panels 65 nos. 11 kv outgoing vcb panels. , 11 kv incoming vcb panels , 11 kv outgoing vcb panels....

Uttar Pradesh Jal Nigam - Uttar Pradesh

37729035 rehabilitation of old sewer line and construction of ips laying of rising main and alternate lying of trunk sewer line to 15 mld mps baniyapur in distt 3 zone 1 kanpur under state sector programme , schedule g1 (repair & laying of trunk sewer line works from gangpur to singhpur tiraha at baniyapur) provision for m.s. sheet of size (3.0 m x 1.8 m) barricading of roads including provision for traffic diversion/ regulation, barricading trench and working area from all sidefor traffic safety during construction period all time, including provisions confiming indian safety codes,caution boards, project boards, night light,watch & ward, 2 m tall barricading boards, reflectors, safety cones, ppe of labours i.e. safety shoes, safety jackets, safety ropes etc t&p etc. , supply of all materials, labour and t&p etc. for making temporary roka arrangement as per requirement in 1000 mm dia existingrcc pipe between mh no. 29 (shivdhampur) to mh no. 31 (gangpur) , de silting of 1000 mm diameter old trunk sewer using high pressure water jetting equipment and super sucker machines including plugging of manholes, pumping and disposal of silt at suitable place as per direction of engineer in charge including all labour , t&p equipment all complete. , repairing of old trunk sewer line by grauting including supply of all material, labour, t&p equipment all complete. , dismentaling/cutting of bituminous road, at following location including stacking properly old serviceable materials and disposal of unserviceable materials as per direction of engineering in charge. including all labour t & p etc complete. mh no. 36 to proposed ips at singhpur tiraha (narchar international school to proposed ips at singhpur tiraha) , providing and conveying to site 1000 mm pccp pipes (pre stressed concrete cylinder pipe) with internal epoxy lining confirming to is 784:2019 at following location including cost of labour, transpotation, loading, unloading , stacking etc. (excluding cost of laying, & jointing etc. mh no. 36 to proposed ips at singhpur tiraha (narchar international school to proposed ips at singhpur tiraha) , excavation of trenches for sewer in ordinary soil, loam, clay or sand by mechanical means (hydraulic excavator) including lead upto 50.0 m filling,watering, ramming excavated earth in to the trenches or spall between the trenches disposal of surplus earth up to distance of 50.0m from centre of the trenches complete work all materials, labour ,machinary , and t&p etc. complete. for repairing of existing pipe line (for depth of 4.50 to 6.0 m) , 0.00 1.50 m , 1.50 3.00 m , 3.00 4.50 m , 4.50 6.00 m , 6.00 7.5 m , supply of all materials, labour and t&p etc. for pumping out subsoil water including pumps, dg set etc. & all arrangement, equipments required for pumping , provide and fixing open(0 3.0m) and close(3.0m 10.50m) timbering in trenches for the different depth below g.l. consisting of 40 mm thick approvedapproved country wood plank for polling board, 125x125 mm form indian sal woodand 100 mm dia ballies for struts @ 1.5 m c/c including removal after laying of sewer, both side of trenches will be taken as one side for the purpose of payment, area equal to length x depth of trenches. for 3.0 to 6.0 m deep , for 6.0 to 9.0 m deep , laying & jointing of 1000 mm dia pccp pipe at following depth including all taxes and duties, transpotation upto site of works as per is 784:2001 or its latest amendment for sewer line with sliding overlap weld joint and joint ring shall be formed by one piece of steel or number of pieces of steel but welded together. the ring shall be expanded beyond their elastic limit so as to achieve accurate dimensions and shape including all setup, equipment,material, t&p, etc for pumping out of subsoil water , for proper laying & jointing, bedding,, centering, boxing of joints, including shifting & reinstatement of utilities of up irrigation dept/ kda/ up awas vikas parishad/ railways/ bsnl / gail/ cugl/ kesco/ military/ jalkal/ up jal nigam etc complete with all materials, labours, t&p etc. 4.50 6.00 m , 6.00 7.5 m , construction ofrcc manhole of, followingsizes as per unit estimate, including all material ,labour and t & p etc. size (1800 x 1800)mm of depth up to 6.00 m , size (1800 x 1800)mm of depth up to 7.50 m , reinstatement of old dismantle bituminous roads as per pwd nh specificationsand new short fallen materials for proper finishing of surface including supply of materials, labour and t&p etc. required for proper completion of work as per direction of engineer in charge. , schedule g2 ( laying of trunk sewer line works from dhanaupur to existing 15 mld mps at baniyapur) providing m.s. sheet of size (3.0 m x 1.8 m) barricading of roads including provision for traffic diversion/ regulation, barricading trench and working area from all sidefor traffic safety during construction period all time, confiming indian safety codes,caution boards, project boards, night light,watch & ward, 2 m tall barricading boards, reflectors, safety cones, ppe of labours i.e. safety shoes, safety jackets, safety ropes etc t&p etc. , dismentaling/cutting of bituminous road, at following location including stacking properly old serviceable materials and disposal of unserviceable materials as per direction of engineering in charge. including all labour t & p etc complete. from dhanaupurwa to 15 mld mps , supply and conveying to site 1000 mm pccp pipes (pre stressed concrete cylinder pipe) with internal epoxy lining confirming to is 784:2019 at following location including cost of labour, transpotation, loading, unloading , stacking etc. (excluding cost of laying, & jointing etc. from dhanaupurwa to 15 mld mps , installation of product pipe by manual pipe jacking method including making of entry and exit pits, all related civil works like excavation, shoring/strutting, etc., manual shielded excavation, lowering of pipe segments in the jacking pit, laying and jointing of product pipeline through jacking process from the jacking pit after project completion as per the instructions of the engineerin charge all complete except the cost of the pipe, , excavation of trenches for sewer by mechanical means (hydraulic excavator) in ordinary soil, loam, clay or sand including lead upto 50.0 m filling,watering, ramming excavated earth in to the trenches or spall between the trenches disposal of surplus earth up to distance of 50.0m from centre of the trenches complete work all materials, labour, , and t&p etc. complete. 0.00 1.50 m , 1.50 3.00 m , 3.00 4.50 m , 4.50 6.00 m , 6.00 7.5 m , supply of all materials, labour and t&p etc. for pumping out subsoil water including pumps, dg set etc. & all equipments required for pumping , provide and fixing open(0 3.0m) and close(3.0m 10.50m) timbering in trenches for the different depth below g.l. consisting of 40 mm thick approvedapproved country wood plank for polling board, 125x125 mm form indian sal woodand 100 mm dia ballies for struts @ 1.5 m c/c including removal after laying of sewer, both side of trenches will be taken as one side for the purpose of payment, area equal to length x depth of trenches. for 3.0 to 6.0 m deep , for 6.0 to 9.0 m deep , laying & jointing of 1000 mm dia pccp pipe at following depth including all taxes and duties, transpotation upto site of works as per is 784:2001 or its latest amendment for sewer line with sliding overlap weld joint and joint ring shall be formed by one piece of steel or number of pieces of steel but welded together. the ring shall be expanded beyond their elastic limit so as to achieve accurate dimensions and shape including all setup, equipment,material, t&p, etc for pumping out of subsoil water , for proper laying & jointing, bedding,, centering, boxing of joints, including shifting & reinstatement of utilities of up irrigation dept/ kda/ up awas vikas parishad/ railways/ bsnl / gail/ cugl/ kesco/ military/ jalkal/ up jal nigam etc complete with all materials, labours, t&p etc. 4.50 6.00 m , 6.00 7.5 m , construction ofrcc manhole of, followingsizes as per unit estimate, including all material ,labour and t & p etc. size (1500 x 1500)mm of depth up to 6.00 m , size (1500 x 1500)mm of depth up to 7.50 m , size (1500 x 1500)mm of depth up to 9.00 m , reinstatement of old dismantle bituminous roads as per pwd nh specificationsand new short fallen materials for proper finishing of surface including supply of materials, labour and t&p etc. required for proper completion of work as per direction of engineer in charge. , schedule g3 ( sump well) excavation in foundation in ordinary soil (loam, clay and sand) for depth given below g.l. for effluent channel laying sewers. manholes, gully pits chambers, sumps etc. including cutting of joints pits, trimming, refilling, dressing leveling of trenches in 20cms layers, watering & ramming the same including removal of surplus earth and other dismantled materials up to 50m from the center of trenches. 0.00 m to 1.50 m , 1.50 m to 3.0 m , making well kerb shoe made of 150*150*18mm angle iron with 250*18mmflat iron brought to required form including supply of steel, bolts, nuts welding etc. complete as per drawing. , 250*12 mm flat , well sinking of 8.0 m (external dia) in ordinary soil below spring level, including supply erection and working of all plants required as well as loading and unloading of weight and bailing and pumping out water with machinery or otherwise as required and disposal of surplus earth upto 5 metre from 0 1.5 metre. , from 1.5 3.0 metre. , from 3.0 6.0 metre. , from 6.0 9.0 metre. , from 9.0 12.0 metre. , cement concrete with followinggauge approved stone ballast, coarse sand and cement in foundation including supply of all materials, labor, t & p etc; required for proper completion of the work. plug (m15) concrete with 20 mm stone ballast, coarse sand and cement 4:2:1 , plug (m15) concrete with 20 mm stone ballast, coarse sand and cement 4:2:1 , sand filling in sump well from well curb to bottom of well slab , r.c.c. 1:1:2 in cement, coarse sand & 20mm gauge stone ballast in well and floor of screening chamber excluding supply of reinforcement and its bending but including its fixing and binding with 0.50mm thick binding wire ( to be supplied by the contractor free of cost) and including necessary centering, shuttering curing and including all materials, labor, t & p etc; required for proper completion of the work. kerb shoe , in base , from kerb shoe to inlet of sewer , from inlet of sewer to top of well , top slab for sump , supply and erection of 250mm ms perforated pipe with blind flange, nut & bolt. , supply and fixing of girder of ismb250 size over the pump house including cost of cutting and wastage as per direction of engineering in charge and its painting with approved paint and also one coat of primer. , mild steel and iron work in rcc to required shape an necessary including bending for proper completion of workk including supply of steel and wastage , supply and painting with anticorrosive paint epoxy base paint inside sump up to roof slab including cost of labour, materials, t&p etc. complete. , supply and fixing of g.i.25 mm dia pipe railing in three row 1.0m.high. , pumping or bailing out of subsoil water for lowering the water table for excavation work, laying of pcd ms work, raft plaster etc. all complete as per station required up to full depth of work the help of well point equipment for 25 days@ 4 pumps , supply of all materials and fixing of aluminium ladder 100 50 channel section (medium) as including cost of 20mm pipe railing, costing of landing, fixing of angles. , provision of ms grill cover over with angle iron frame of 40*40*6mm on working platform , provision of water proofing compound for construction under sub soil water. , schdule g4 (rising main) supply of 350mm dia.pipe and specialssuitable for destination including all taxes. 350 mm dia di k 9 pipes , supply & fitting of specials @ 10% of 1(a) & 1(b) , dismantling of bitumin roads disposal of unserviceable materials within 50m from the site of work as directed by the engineer in charge including its temp reinstatement by hand ramming to make walkable. , excavation for pipe lines in ordinary soil lift upto following and lead upto 50m including filling back, watering, ramming in trenches and removal of surplus earth. 0.0 to 1.5m , laying & carting ofpipes and specials of 350mm dia. from store to the site of work, lowering them into the trenches and laying and jointing to alignment including testing of pipe. 350 mm dia di k 9 pipes , construction of thrust blocks of size 1.8m x 1.8m x 1.8m , supply & fitting of air valves of size 25mm. , reinstatement of old dismantle bituminous roads as per pwd nh specificationsand new short fallen materials for proper finishing of surface including supply of materials, labour and t&p etc. required for proper completion of work as per direction of engineer in charge. , site clearance & other unforeseen items. , schdule g5 (d.g. plate form) size of d.g. plateform size of transformer plateform concrete in 1:4:8 with cement, coarse sand and 40mm gauge stone ballast including supply of all materials labours and t&p etc. required for the proper completion of work. transformer , d.g set , reinforced cement concrete in1:1.5:3 with cement coarse sand and 20mm stone grit in foundation footing etc. excluding supply of reinforcement and its bending but including its fixing, binding the same with 0.50mm thick binding wire (to be supplied by the contractor) including of all materials, labour, and t&p etc. required for the proper completion of work transformer , d.g set , cable trench for d.g set p.c.c (1:4:8) , floor slab , vertical wall , cover , mild steel or iron work in plane work such as in r c.c work (when not included in over all rates; wrought to the required shape as necessary including bending for the completion of work and including supply of all matenals, labours, t&p etc. complete , provision for ms grill in 2.0m height all around dg set for safety against theft and tempering etc. , provision for tubular truss in mild steel or iron work in heavy section including drilling revetting and welding and also including supply of steel bolts,nuts and their fixing required for proper completion of work , supply & fix 0.63mm thick ridges,valley & gutter for gc iron roofing , schdule g6 (meter, ht & lt panel room) construction cost of lt panel room building(6.0m x 5.0m) , construction cost of meter and ht panel room building (5.5m x 8.0m) , schdule g7(boundry wall, gate and site development) excavation of earth in ordinary soil (loan, clay and sand) in manhole, gully pits, sump and chambers for depth upto 1.50m below g.l. including watering, ramming, dressing, filling back between wall and foundation and disposal of surplus earth with 50m including supply of all labours and t&p etc. required for the proper completion of work. , concrete in 1:4:8 with cement, coarse sand and 40mm gauge stone ballast including supply of all materials labours and t&p etc. required for the proper completion of work. , mild steel for raft of column of size 1000 mm x 1000 mm (12 mm dia bar of spacing 150 mm) , distribution bar for raft of column (12mm dia bar spacing 150 mm) , mild steel for column of size 230 mm x 230 mm (12 mm dia bar) , distribution bar (8 mm dia bar spacing 250 mm) , mild steel for beam of size 230 mm x 230 mm (10 mm dia bar) , distribution bar (8 mm dia bar spacing 150 mm) , mild steel for copping of size 230 mm x 150 mm(8 mm dia bar) , distribution bar (8 mm dia bar spacing 200 mm) , r.c.c. work with cement coarse sand and 20 mm gauge approved stone ballast in proportion 1:1:5:3 in columns excluding supply of reinforcement and its fixing and binding with 0.50mm thick binding wire to be supplied by the contractor and including necessary centering and shuttering supply of all material, labour t&p etc. required for proper completion of the work. r.c.c. work for column of size 230 mm x 230 mm , r.c.c. work for beam of size 230 mm x 230 mm , r.c.c. work for copping of size 230 mm x 150 mm , 1st class brick work in 1:4 cement, & coarse sand mortar in foundation and plinth including supply of all materials labour t&p etc. required for proper completion of thework. , ist class brick work in 1:4 cement, and coarse mortar in super structure including supply of all materials labour t&p etc. required for proper completion of the work , 12 mm thick 1:4 plaster with cement, and coarse sandover brick minimum thickness not be less than 10mm including supply of all materials, labour, t&p etc. required for propre completion of work. , weather proof painting of reputed company (asian, berger) two coats using approved coloring materials of buff, blue brown shades over one primary coat including supply of all materials labour t&p etc. required for proper completion of the work , earth filling in plinth including supply of necessary quantity of earth from a distance not exceeding 10 km. from the site of work and including watering, dressing etc. rate to include the cost of all materials, labour t & p etc. required for proper completion of work. , supply and fix m.s. clamps of size 50x50x6x100 mm for gates including supply of all materials labour , t&p etc . required for proper completion of the work . , supply and fixingof m.s. gate of 3.60 m wide as per type design including necessary fabrication for proper completion of work. , same as above but for wicket gate 1.2 m as per type design. , supply of all material and labour t & p etc for making drain in campous as per unit estimate , supply of all material and labour t & p etc for making internal interlocking road in campous as per unit estimate , fixing of 40 mm dia p.v.c. conduit pipe including specials & cutting etc. for clectric wiring including supply of all materials labour, t&p etc. required for propre completion of work. , painting the gate with one cost of primer and two coats of approved paint including supply of all materials, labour, t&p etc. required or proper completion of work , for wicket gate 1.2 m as per type design , supply of all material and labour t & p etc for making external cc road outsidecampous as per unit estimate , provision for other unforseen item and site development , schedule g 8 (tapping arrangement, screen channel and other appurtenant works ) excavation of earth in ordinary soil (loan, clay and sand) in manhole, gully pits, sump and chambers for depth upto 1.50m below g.l. including watering, ramming, dressing, filling back between wall and foundation and disposal of surplus earth with 50m including supply of all labours and t&p etc. required for the proper completion of work. for screen channel 0.00 – 1.50m , supply of all materials, labour and t&p etc. for pumping out subsoil water including pumps, dg set etc. & all arrangement, equipments required for pumping , concrete in 1:4:8 with cement, coarse sand and 40mm gauge stone ballast including supply of all materials labours and t&p etc. required for the proper completion of work. for screen channel , reinforced cement concrete in1:1.5:3 with cement coarse sand and 20mm stone grit in foundation footing etc. excluding supply of reinforcement and its bending but including its fixing, binding the same with 0.50mm thick binding wire (to be supplied by the contractor) including of all materials, labour,and t&p etc. required for the proper completion of work bed slab of screen channel , vertical wall of screen channel , plateform for cleaning of screen , mild steel or iron work in plane work such as in r.c.c work (when not included in over all rates) wrought to the required shape as necessary including bending for the completion of work and including supply of all materials, labours, t&p etc. complete. , supply of all material ,labour and fixing of s.s. gate for inlet channel of 12 mm thickplate of following size including frame ,spindle etc screen channel(2.0m x 1.0m) , providing and fixing mild steel ladders for entering in to sump and valve chamber made up of standard channel section, chakered plates and equipped with 32mm diameter gi pipe railing welded and finshed as per satisfaction of engineer incharge including supply of all materials labour and t&p etc forproper completion of work. , schedule of ( e&m) work ips singhpur tiraha works to be carried out by u.p.jal nigam h.t.panel( comprising with 1 i/c and 2 o/g. supply , installation, testing and comissioning of 2mm. thick factory made 11 kv, 630 a, 20ka / 3 sec, out door extensible type ip54 for panel & ip67 for main circuits ring main unit (rmu) iec 62271 200 in suitable rcc foundation with 2 no.load break switch & 1 no. vcb circuit breaker with over load, earth fault, short circuit relay, copper bus bar, bus support and insulation marerial epoxy resin,ring core protection & metering ct, auxiliary relay for wti, oti, bucholz alarm & trip along with annuciator panel, master trip relay, mechanical on / off / earth indication, voltage presence indicator, shunt trip coil, 24 v dc power pack, digital multi function meter, with bus pt panel with 3 nos single phase voltage transformers of the ratio 1kv/v3 / 110 v/v3, 25 va, class 1.0 with ht fuses in the primary and mcb on the secondary side, voltmeter with selector switch, r y b phase indication, anti reflex operating handle, right angle boots etc. every vcb panel should have 1 power pack with battery charger and charging device complete in all respect. (1 incoming and 2 outgoing) ref.e230700 (pre bsr 2021) , providing & laying xlpe insulated as per is:7098/ii/85 h.t.cable as per pwd specification for electrical works for working voltage 11 k.v.(e) in existing rcc / hume /stoneware / pvc pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. 3 core x 120sq.mm. armored ht cable (from ht panel to transformers) ref.e130101 (pre bsr 2021) , trench making and covering of trench in all respect. ref.e130300, e130400, e130500 and e130700 and (pre bsr 2021) , sitc of 11 kv end termination kit indoor type (3 core, 120sq.mm) ref.e131313 (pre bsr 2021) , 11 kv, 2.5 mm thick with proof voltage 22 kv / 3 min. and break down voltage 45 kv ref.e081202 (pre bsr 2021) , transformer: s i t c of oil cooled copper wound distribution transformer of 200 kva rating 11/0.433kv delta star connected, vectordyn 11,onan cooled & bis approved as per is ,losses as defined as per is 1180 part i 2014. including standard accessories like conservator, silica gel breather, radiator, fins, ht cable box & lt cable boxes, temperature rise in winding/oil 35 40 degree c, isi marked drain valve, dial type temperature gauge, first filling of transformer oil as per is :335 1953, epoxy based paint, including carrying of pre commission testing & charging of transformer complete in all respect.(as per budgatry offer attached). rating and diaphram plate,earthing terminals, lifting lugs,dial type thermometer for winding temp. indication., marshalling box, enclosure, safety interlock facility for doors, externally operated off load changing switch with lock&key, under base skid with flat roller, l.t.& h.t. terminal boxes. , l.t. panel sitc of 0.415 kv l.t. control panel for pumping plant l.t. control panel suitable to operatedon 415 ± 6 %volt , 3 phase , 50 hz, ac supply as per details given below (a) 2 nos incoming panels and 1 no. outgoing panels, 1 no. panel for dg set each consisting of following items (i) 400 amp mccb 1 no.(ii)c.ts of suitable ratio 1 no.(iii)ammeter with selector switch 1 no.(iv) voltmeter with selector switch 1 no. (v)power factor meter(0.5 lag&0.5lead) 1 no.(vi)frequency meter 1 no.(vii)kwh meter 1 no. (viii)2 pole over current relay& one pole earth fault relay and trip alarm availability 1 no.(ix) extended rotary handle 1 no. (b)bus bar chamber having 3 nos. bus bars for phase and 1 no. bus bar for neutral of suitable size – 1 no. (c) 3 nos. composite panels for 50 hp pumping plants, each consisting of following items –(i)160 a mccb 1 no.(ii)c.ts. of suitable ratio 1 no.(iii)ammeter with selector switch 1 no.(iv) automatic start / stop device according to level in the sump 1 no.(v)indicating lamps(auto/manual/low level/ reverse rotation) 1 set (vi) earth fault, under voltage and trip alarm availability 1 set (vii) extended rotary handle 1 no.(d) 2 nos. composite panels for 11 hp pumping plants, each consisting of following items –(i)40 a mccb 1 no.(ii)c.ts. of suitable ratio 1 no.(iii)ammeter with selector switch 1 no.(iv) automatic start / stop device according to level in the sump 1 no.(v)indicating lamps(auto/manual/low level/ reverse rotation) 1 set (vi) earth fault, under voltage and trip alarm availability 1 set (vii) extended rotary handle 1 no. (e) 3 nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) mcb of 40 a capacity 1 no.(ii) c.ts. of suitable ratio 1 no. (iii) ammeter with selector switch 1 no.(iv) indicating lamps 1 set (f)auto power factor correction panel for total load. (g) rubber resistance sheet (ref. as per attached analysis) , lt cable laying and jointing supply, laying, testing and commissioning of lt cables for whole pumping station from power supply side which includes 300sqmmx3.5corex1run armoured aluminium cable for transformer to main lt panel with lugs jointing etc. complete and cabling work of 150sqmm.x3corex1 run un armoured aluminium from starter to motor with lugs jointing etc.complete. (ref. as per attached analysis) , earthing plate earthing as per pwd specification for electrical works as per is:3043 with copper earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. g.i. b class watering pipe ,including all accessories like nut, bolts, reducer, nipple,wire meshed funnel, and heavy duty weather proof polypropylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less (4 for transformers and 2 for ht panel) ref.e140300 (pre bsr 2021) , pipe earthing as per pwd specification for electrical works as per is:3043 1987 with 3.0 mtr. long, 40 mm dia. b class g.i. pipe is: 1239 (part 1) 2004, equivalent to bs :1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms (2 for lt panel and 1 for ht panel)ref.e140100 (pre bsr 2021) , supply & laying of 50mmx6mm size gi earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, jointing shall be done by overlapping and with 2 set of gi nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) ref.e140611 (pre bsr 2021) , charges of electrical safety clearance expenditure on b&l form, challan etc. , proper fencing of substation portion as per i.e. rules. (ref. ongoing amrut work aligarh sewarage) , starter panel compraising of soft starter, suitable to meet the basic requirement of motor protections and suitable to run 50 hp motor (to be fixed in composite panel of lt panel) ref. up jal nigam e&m sor, 2020 , compraising of soft starter, suitable to meet the basic requirement of motor protections and suitable to run 11 hp motor (to be fixed in composite panel of lt panel) ref. up jal nigam e&m sor, 2020 , pump 3840lpm and 29 met head 3nos. non clog submersible sewage pump suitable for handling raw sewage of specific gravity 1.03 and electric motor with digital soft starters suitable for operation on 400 ± 10% volt, 3 phase, 50 hz, ac supply system having following specification capacity 3840 lpm total head 29 meters rpm 1000 solid passable at least 100 mm accessories of each submersible pumping plant (a) pedestal with autocoupling (b) s.s. guide pipeapprox 12 m (c) s.s. chain with shacklesapprox 12 m (d) c.i.d.f, bend 200 mm dia x 350 , pump 1460lpm and 17 met head 2nos. non clog submersible sewage pump suitable for handling raw sewage of specific gravity 1.03 and electric motor with digital soft starters suitable for operation on 400 ± 10% volt, 3 phase, 50 hz, ac supply system having following specification capacity 1460 lpm total head 17 meters rpm 1450 solid passable at least 100 mm accessories of each submersible pumping plant (a) pedestal with autocoupling (b) s.s. guide pipeapprox 12 m (c) s.s. chain with shacklesapprox 12 m (d) c.i.d.f, bend 150 mm dia x 350 , installation, tesing, commissioning of above 5 pumps and starters@10% , supply of main piping & valves complete with common header alongwith all neessary nuts, bolts, rubber packing etc., as per following details. 200mm dia cidf reflux valves(ref. attached sor of ivc with ce (e./m.), up jal nigam letter) , motor operated actuator with 200mm dia cidf sluice valves(ref. attached up jal nigam sor,2020) , 150mm dia cidf reflux valves(ref. attached sor of ivc with ce (e./m.), up jal nigam letter) , motor operated actuator with 150mm dia cidf sluice valves(ref. attached up jal nigam sor,2020) , 350mm dia cidf reflux valve(ref. attached sor of ivc with ce (e./m.), up jal nigam letter) , motor operated actuator with 350mm dia cidf sluice valves(ref. attached up jal nigam sor,2020) , 200 mm dia di k9 delivery line (sor of material manager, up jal nigam attached) , 150 mm dia di k9 delivery line (sor of material manager, up jal nigam attached) , 350mm dia di k9 common header(sor of material manager, up jal nigam attached) , nut, bolt, washer, rubber & gasket etc. @ 5% of a to i , specials like tee, bend, blind flenge, d joint etc. @ 10% of a to i , installation, testing, commissioning of a to k @10% , metering apparatus and sensors gauges supply of pressure transmitter at delivery line of each pump along with fitting accessories to measure pressure for control and alarms. , electro magnetic flow meter suitable electro magnetic flow metersuitable to measure 0 to 20 mld flow to be fitted in 350 mm dia main header line.(ref. up jal nigam e&m sor, 2020) , errection, commissioning,testing charges of flow meter , level transmitter ce/ul certififed radar type level transmitter for ips (ref. up jal nigam e&m sor, 2020) , installation, testing, commissioning , e.o.t. crane sitc of e.o.t. crane of 3 tonne capacity along with gantry girders, chain pulley, block and geared trolley suitable for 10 m span 5 m clear lift complete in all respect for pump house. detailed specifications are as below confirming to i.s. 3177 and i.s.3832 chain pulley block capacity 3 ton with 15 m lift arrangement. (ref. amrut ongoing work in sewerage aligarh contract bond) , chequerred plate and guards sitc of 3mm thick m.s chequerred plate over all the run of cables trenches to cover properly and m.s. grill and m.s. guard over all pipes ducts and other point where required as per site condition (ref. up jal nigam, se aligarh rate) (3x0.75+5x0.75+8x0.6+8x0.6)x1=15.60sqmm. , painting painting of all pumps piping and valves with two coat enamel paint. (ref.up jal nigam e&m sor, 2019) , light wiring & electrification (ref. up jal nigam e&m sor, 2019) complete internal electrification of lt panel room with 2 nos. exhaust fan , complete internal electrification of ht panel room with 2 nos. exhaust fan , water works campus with solar panel and led light of 3 sets. , bar screens (20mm) provision of suitable manual bar screen having 20mm clear gap between screen bar of s.s. flat (50mmx10mm size) and angle of installation 600 with suitable size in width. , electrically operated s.s. 304 mechanical coarse bar screen with ultrasonic level sensors and transmitters, screen panel and conveyor belt system, motors capable of handling screenings complete with cable from lt panel to screen panel and hand operated trolley for lifting screenings from screen. , installation, testing, commissioning@10% , sluice gates provision of thimble mounted c.i. sluice gate having rising spindle and flush bottom system with cast iron frame, cast iron shutter, ss 410 stem, gun metal stem nut, ss 304 fasteners etc. suitable to handle smoothly, peak flow of sewage at ips. , installation, testing, commissioning , dg set supply , installation, testing and comissioning of 180 kva at 0.8 pf 415v 50hz 3 ? silent dg set (as per latest cpcb emission norms) having 1500 rpm diesel engine conform to bs:649/5514 of suitable bhp engineshall have residential silencer (isolated from main dg chamber), up to 3 m exhaust piping (with insulation & cladding ) .alternator shall be self regulated with standard alternator protection(over voltage , over speed & under voltage, under speed warning &shutdown).engine & alternator mounted on a common base frame &coupled through a flexible coupling or close coupled.standard canopy with weatherproof, powder coated accoustic enclosure for dg set for sound attenuation fabricated from 1.6 mm crca sheet steel(structure) with side wall fabricated from 1.6 mm crca sheet & filled with glass wool (96kg/m3)/ foam. as per is 8183 the doors of 28/40/50/85 mmthick as per rating and fabricated from 1.6mm crca sheet packed withaccoustic material,all doors/ opening are sealed with neoprene/epdngaskets. the enclosure has built in fuel tank, with protection and tripping of dg set against temperature of more than 50 degree centigrade.electronic / mechanical governor, manual & electric start ,batteries withbattry charger, engineinstruments panel,avm pads all controls for operation of dg set are from outside the enclosure. the enclosure should be suitable for 180 kva capacity dg sets and alternator. noise level shall be less than 75 db at a distance of 1 mtr. duly certified by authorised agency etc. complete in all respect. (ref.e231533 pre bsr 2021) , supply , installation, testing and comissioning ofplc based auto main failure (amf) panel fabricated from crca sheet steel 2 mmthick , powder coated finish , engine start & stop commands, control relays , ammeter & voltmeter with selector switches, control & 2 nos 4 pole power contactors with 2 no. of required size 4 pole mccb, timers, electronic hooter ,visual & alarm indication for faults, ups, operator interface panel complete in all respect suitable for following capacity dg sets. oem must have bis certificate and & shall have submit nabl / cpri / erda lab type test reports before execution as required complete in all respect. (ref.e231614 pre bsr 2021) , lt cable laying and jointing for dg set supply, laying, testing and commissioning of lt cables for dg set to lt panel which includes 300sqmmx3.5corex1run armoured aluminium cable from dg set to amf panel and amf panel to main lt panel with lugs jointing etc. complete.(ref. as per attached analysis) , scada system ( up jal nigam e/m sor 2020 approved rate attached) on lineups for plc supply, 3 kva with 3 nos. 12v/65 ah amf battery with dynamic isolation. , supply of auto phase reversal unit. (160 amp) , complete cabling upto 5 pumpsets in sump including cable in pumping plant room, pressure transmitter to room, flowmeter to room etc. , supply , installation, testing, interfacing & commissioning of cc tv camera with ups , ce/ul certified local control room plc/rtu with redundant cpu & power supply at lcs in ip54 encloser as specification mentioned in technical bid documents. panel with plc to control all the starters of motor and starter of actuators for pump set. the plc to accommodate analog signals from flow transmitter, level transmitter& pressure transmitter etc. , gsm/gprs based wireless communication with 5g modem for rtu/plc capable to transfer & gather data from remote sites to control station all accessories included with signal enhancer antennaa made for pumping plant internet charges as specified in tender technical specification. , full development version of required tags scada software with customisation of software for lcs as per requirement . , desktop(computer) /pc with i5/i7 processor with latest configuration mouse, keyboard etc , printer a3 size...

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

37647099 replacement & overhauling 11 kv incoming and outgoing vcb panel at 33 / 11 substation bhinga for redundancy and to ensure uninterrupted power supply, under the head of business plan 2023 24 under geographical area of electricity distribution division balrampur / tulsipur. all the following work will be execute according to sanctioned estimate / package as per resspo u.p.p.c.l. drawing / norms....

Kanpur Electricity Supply Co Limited - Uttar Pradesh

37563145 work of replacement of damaged conductor to new dog conductor at koyla nagar substation and replacement of damaged 11 kv vcb panel at sujatganj substation in daheli sujanpur division under the area of e.u.d.c. iii kesco. kanpur...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37433993 supply of vaccume interrupter suitable for different make 11 kv vcb (panel) installed at various 33 kv substation under the jurisdiction of superintending engineer, electricity urban distribution circle, mathura , supply of vaccume interrupter suitable for different make 11 kv vcb (panel) , abb , biecco , crompton greeves , stelmec , siemens , bhel , electroteknica switchgears , pascal , ece , yamuna power...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

37297642 tender for electrification of atal avasiya vidhyalay belhat in full deposit scheme under edd meja 1 safe carriage of following materials store centre naini, prayagraj to work side village belhat, koraon including loading & unloading distance 70 km above 2 s.t. pole ( 11 mtr long ) 3 a.c.s.r. weasel conductor 4 transformer 630 kva 5 11 k.v. vcb. panel 6 electronic tvm 11 kv 7 11 kv pilfer proof metering cubical 8 11 kv line materials 9 3 phase 4 wire l.t. tvm 3×240v with lpr 10 11 kv ctpt 11 xlpe cable 3×1852mm 12 xlpe cable 3×702 mm 13 l.t. cable 1×6302mm 14 erection of 11 kv line 15 digging of pits & mounted of pole ( fitting of all accessories ) 16 digging of pits & mounted of sectional double pole ( fittings of all accessories with x breasing ) with grouting 17 digging of pits & mounted of four / try pole ( fittings of all accessories ) with grouting 18 stay complete grouting & nazaling ( respo norm 1:2:4 ) 19 grouting of s.t.pole ( respo norm 1:2:4 ) 20 earthling complete ( respo norm 1:2:4 ) 21 erection of 28 km h.t. line– fitting of all accessories saging of line, fixing of p.g. clamp binding, jumpring & proper stocking 22 laying of 3×1852 mm ( resp norm ) 23 laying of 3×702 mm ( resp norm ) 24 guarding of line 25 installation of pannel & cubicle 26 supply of materials 27 top + t off clamp 28 stay clamp 29 u clamp 30 guarding clamp 31 e clamp 32 nut, bolt & washer 33 guarding clamp 34 gst extra as legally applicable...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37297478 tender for vcb repairing work under edd deoband 2 repairing & setting of on and off tripping mechanism system together with adjustment of main shaft with replacementof sundary itam such as bus pin washer nut & bolt spring and wiring etc. complete cleaning and washing 3 remove of 11 kv vcb panel after disconnecting the connections. 4 instalationand fxing of vcb in panel making of connection with adjustment & proper energisation of vcb in perfect working order. 5 re setting of vaccume interrupter of vcb properly fittinig complete ( 03 sets ) 6 opening of 06 no. bushing rod and refitting the same after cleaning. 7 re setting of male and female fingger contact with cleaning etc. 8 cleaning of carbonized spout assembly bus ans cable box side by including cleaning of vcb panel and bus bar. 9 repairing andfitting of small and big graree from 11 kv vcb. 10 repairing and fitting of baring and charging rod from 11 kv vcb....

Department of Defence Production - Uttar Pradesh

37231801 bids are invited for ht vcb panel basic cost including accessories for ht vcb panel , packing forwarding insurance and transportation cost , cost of civil works , errection and commissioning charges , training charges including cost of manuals total quantity : 5...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

37204811 electrification of atal avasiya vidhyalay belhat in full deposit scheme under edd meja 1 safe carriage of following materials store centre naini, prayagraj to work side village belhat, koraon including loading & unloading distance 70 km above 2 s.t. pole ( 11 mtr long ) 3 a.c.s.r. weasel conductor 4 transformer 630 kva 5 11 k.v. vcb. panel 6 electronic tvm 11 kv 7 11 kv pilfer proof metering cubical 8 11 kv line materials 9 3 phase 4 wire l.t. tvm 3×240v with lpr 10 11 kv ctpt 11 xlpe cable 3×1852mm 12 xlpe cable 3×702 mm 13 l.t. cable 1×6302mm 14 erection of 11 kv line 15 digging of pits & mounted of pole ( fitting of all accessories ) 16 digging of pits & mounted of sectional double pole ( fittings of all accessories with x breasing ) with grouting 17 digging of pits & mounted of four / try pole ( fittings of all accessories ) with grouting 18 stay complete grouting & nazaling ( respo norm 1:2:4 ) 19 grouting of s.t.pole ( respo norm 1:2:4 ) 20 earthling complete ( respo norm 1:2:4 ) 21 erection of 28 km h.t. line– fitting of all accessories saging of line, fixing of p.g. clamp binding, jumpring & proper stocking 22 laying of 3×1852 mm ( resp norm ) 23 laying of 3×702 mm ( resp norm ) 24 guarding of line 25 installation of pannel & cubicle 26 supply of materials 27 top + t off clamp 28 stay clamp 29 u clamp 30 guarding clamp 31 e clamp 32 nut, bolt & washer 33 guarding clamp 34 gst extra as legally applicable...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37160442 work of construction of lt line, construction of 11 kv line, work of replacement of vcb panels, replacement of damaged underground cable and other important related works under the area of distribution divisions under electricity distribution circle, firozabad....

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37154799 work of replacement of defective 11 kv outgoing vcb panels at various 33 / 11 kv sub stations under power distribution division ii, etawah. 1 carriage of 11 kv outgoing vcb pannel ctr 400 / 200 / 5 amp. from store centre kunera etawah to dump site of workunder jurisdiction of edd ii etawah. 2 dismenteling of old and used vcbs ( outgoing pannel ) from control room and safely store in outside of controle room 3 installation of new 11 kv outgoing vcb pannel in controle room and connecting all equipments. 4 back carriage of old & used 11 kv outgoing vcb pannel from site to je store concern / store centre, kunera etawah....

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37011840 work of repairing and overhauling of various makes vcbs installed at 33 / 11under jurisdiction of edd fatehbad. 2 insulation paint inside of 11 kv vcb ( bhel, toshiba & stelmec and other makes ) panel on all epoxy items i.e. c.t., drive insulators, c.t. & bus bar side spout and vaccum chambers etc. 3 replacement of tripping assembly complete with housing and plungers suitable for 11 kv vcb ( bhel, toshiba & stelmec and other makes ) 4 replacement of charging grear complete set with lead screw along with bearing suitable for 11 kv vcb. 5 replacement of auxiliary switch. 6 replacment of jack rod with complete set of mechanism suitable for 11 kv vcb. 7 overhauling of busbar including providing proper insulation by using empire, h.t. tape. 8 11 kv vcb panel amp meter / volt meter / amp / volt selector switch / indicators. ( blowing lamp ) t&c switches etc as required suitabel for ( 11 kv vcb bhel, toshiva & stelmec make. 9 testing of o / c and e / f of 11 kv vcb through primary injection set. 10 wiring of panels ....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37011485 approved in the business plan 2023 24, 630 kva bareilly ka madrasa due to overloading of 400 kva transformer at kamela road, duda colony, in the working area of ​​electricity urban distribution division first, saharanpur. work of replacement of dilapidated abc at 250 kva mohalla daud sarai and replacement of 11 kv outgoing vcb panels installed at sub centre ghantaghar....

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36949497 work for construction of 11 kv / lt line in business plan for area expansion of nagar palika hathras in the area of eudd hathras 2 pcc 8.5 mtrlong 3 stp pole 13 m long 4 stp pole 11m long 5 stone pad 6 acsr dog conductor 7 11 kv xlpe cable 3x185 sqmm 8 3x120+1x95+1x16 sq mm ab cable 9 3x50+1x35+1x16 sq mm ab cable 10 lt pvc cable al 3.5*400 sqmm 11 lt pvc cable al 1*400 sqmm 12 t / f 250kva 11 / .4 kv new 13 t / f 400kva 11 / .4 kv new 14 11 kv v.c.b outgoing 15 gi pipe 6 dia 16 hdpe pipe undergrouding minimum 3 mtr 160 mm od pn 4pe 80 grade u.v stablized hdpe pipe as is:4984 in 6 metre 17 11 kv cable jointing kit 18 earthing set complete 19 stay set complete 20 11 kv v type cross arm complete 21 11 kv pin insulator with pin 22 11 kv disc insulator complete 23 lt incoming panel with metering equipment 24 f bracket 25 tee off channal 26 number plate 27 barbed wire 28 danger board with clamp 29 guarding angle complete 30 g.i wire 6 swg 31 g.i wire 8swg 32 suspension clamp with i hook complete 33 dead end clamp 34 3 phase lt distribution box with holding clamp 35 lt insulation pearacing clamp with pearcing conn. 36 top channal 37 dropper channal 38 11 kv fuse set 39 11 kv tpmo complete 40 clamp for top & dropper channal with n&b 41 cross bracing m.s angle 42 clamps with bolt & nut 43 p.g clamp 44 lt piller box 45 al lug 400 sqmm 46 nut, bolt & washer 47 scope of work 48 errection and grouting of following poles including cutting of kharanja / mettalic road / concrete portion while digging pit & complete h.t. / l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work. 49 8.5 mtr. long pcc poles. 50 11 / 13 mtr. s.t. poles 51 double pole complet fitting 52 four pole with complete fiting 53 laying, sagging and stringing and nozzling / binding etc. ofnew &old acsr weasal conductor / giin 11 kv / lt lines as per respo manual and as per direction of supervising engineer. 54 acsr dog / racoon conductor 55 3*120+3*95 sqmm. ab cable 56 3*50+1*35+1*16 sqmm ab cable 57 xlpe cable of size 3*185mmsq 58 lt pvc cable al 3.5*400 sqmm 59 lt pvc cable al 1*400 sqmm 60 safe installation offollowing new cousted t / fin proper alignment direction & making all ht / lt connection. 61 400 kva t / f 62 250 kvat / f 63 fixing of hdpe pipe undergrounding minimum 3 mtr 160 mm od pn 4pe 80 grade u.v stablized hdpe pipe as is:4984 in 6 mtr 64 fixing of gi pipe 6 dia 65 fixing of followingclamps for completion of work 66 danger board 67 number plate 68 tpmo 69 3 phase lt distribution box 70 11 kv fuse set 71 fixing of 11 kv cable jointing kit 72 errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast / stone ballast etc. shall be arranged by the contractor at his own cost. 73 fixing of earthing rod as per respo norms and as per direction of supervising engineer. 74 construction of plinth of size 5 * 5 * 4 above ground level one ft below the ground level of 9 after exavation of 4 earth brick ballast shall be provided and rammering willbe done properly after ballast shall be provided and rammering will be done properly after that a retaining wall 9width by fist class brick in ratio 1:4 of cement & sand shall be made . the earth shall be filled up to one ft.below the top of the plinth after this brick ballast shall be provided upto 6from the earth level and proper rammering shall be done one no. jall of 12 mm ms tor shall be fixed in the hollow of plinth and one ft. thick rcc in ratio of cement sand & stone ballast shall be laid on the top of the plinth. the 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand. 75 pipe earthing of 250 / 400 kva medium power transformers 76 net fencing shall be 1150*1200 mm made of 35*35 mm ms angle covered by expended netal 14 swg up to full height 1200 mm duly steftened by ms flat by an 8 swg dia bolt & nut 77 guarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg / 8 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x guards ( tillis ) of gi wire at distance of 3 mtr. 78 fixing and grouting of lt incomming pannel with metering equipments 79 safe dismantling offollowing old & usedt / f with opening of all connection with safe carriage up to je store / esc hathras ( distance range 0 to 50 km ) 80 250kva t / f 81 100 / 63kvat / f from double pole 82 installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the t pole shall be grouted with cement, sand and brick ballast / stone ballast in ratio 1:4:8 including the cost of material. 83 safe dismenteling of old 5 mva t / f from foundation and carriage it from switch yard to out side boundary 84 fixing and grouting with earthing of 11 kv vcb panel 85 construction of plinth suitable for10 mva t / fabove ground level one ft below the ground level of 9 after exavation of 4 earth brick ballast shall be provided and remaining willbe done properly after ballast shall be provideda retaining wall 9width by fist class brick in ratio 1:4 of cement & sand shall be made . the earth shall be filled up to one ft.below the top of the plinth after this brick ballast shall be provided upto 6from the earth level and proper rammering shall be done one no. jall of 12 mm ms tor shall be fixed in the hollow of plinth and one ft. thick rcc in ratio of cement sand & stone ballast shall be laid on the top of the plinth. the 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand. 86 making all h / t / jumpers of installed new / repaired 10 mva t / f after completion of work 87 earthing of 10 mva power t / f ( body & neutral ) 88 cutting, chopping, triming of tree branches to clear the line route to give2 mtr. horizontal and vertical clearance to the line coming in the route ofdifferent feeders as per direction of supervising engineer...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36949390 work for construction of 11 kv / lt line in business plan for area expansion of nagar panchayat sadabad in the area of edd iv sadabad. 2 pcc 8.5 mtrlong 3 stp pole 11m long 4 stone pad 5 acsr dog conductor 6 11 kv xlpe cable 3x185 sqmm 7 3x120+1x95+1x16 sq mm ab cable 8 lt pvc cable al 3.5*150 / 70sqmm 9 lt pvc cable al 3.5*400 sqmm 10 t / f 100kva 11 / .4 kv new 11 t / f 250kva 11 / .4 kv new 12 11 kv v.c.b outgoing 13 11 kv v.c.b incoming 14 gi pipe 6 dia 15 11 kv cable jointing kit i / d and o / d 16 earthing set complete 17 stay set complete 18 11 kv v type cross arm complete 19 11 kv pin insulator with pin 20 11 kv disc insulator complete 21 lt incoming panel with metering equipment 22 f bracket 23 tee off channal 24 number plate 25 barbed wire 26 danger board with clamp 27 dead end clamp 28 3 phase lt distribution box with holding clamp 29 lt insulation pearacing clamp with pearcing conn. 30 top channal 31 dropper channal 32 11 kv fuse set 33 11 kv tpmo complete 34 clamp for top & dropper channal with n&b 35 cross bracing m.s angle 36 clamps with bolt & nut 37 p.g clamp 38 lt piller box 39 al lug 120 sqmm 40 al lug 400 sqmm 41 suspension clamp with i huck complete 42 i hook with i bolt 43 nut, bolt & washer 44 scope of work 45 errection and grouting of following poles including cutting of kharanja / mettalic road / concrete portion while digging pit & complete h.t. / l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work. 46 8.5 mtr. long pcc poles. 47 11 / 13 mtr. s.t. poles 48 double pole complet fitting 49 laying, sagging and stringing and nozzling / binding etc. ofnew &old acsr weasal conductor / giin 11 kv / lt lines as per respo manual and as per direction of supervising engineer. 50 acsr dog / racoon conductor 51 3*120+1*95 sqmm. ab cable 52 xlpe cable of size 3*185mmsq 53 lt pvc cable al 3.5*150 / 70 sqmm 54 lt pvc cable al 3.5*400 sqmm 55 safe installation offollowing new cousted t / fin proper alignment direction & making all ht / lt connection. 56 250 kvat / f 57 100 kva t / f 58 fixing of gi pipe 6 dia 59 fixing of followingclamps for completion of work 60 danger board 61 number plate 62 tpmo 63 3 phase lt distribution box 64 11 kv fuse set 65 fixing of 11 kv cable jointing kit i / d and o / d 66 errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast / stone ballast etc. shall be arranged by the contractor at his own cost. 67 fixing of earthing rod as per respo norms and as per direction of supervising engineer. 68 construction of plinth of size 5 * 5 * 4 above ground level one ft below the ground level of 9 after exavation of 4 earth brick ballast shall be provided and rammering willbe done properly after ballast shall be provided and rammering will be done properly after that a retaining wall 9width by fist class brick in ratio 1:4 of cement & sand shall be made . the earth shall be filled up to one ft.below the top of the plinth after this brick ballast shall be provided upto 6from the earth level and proper rammering shall be done one no. jall of 12 mm ms tor shall be fixed in the hollow of plinth and one ft. thick rcc in ratio of cement sand & stone ballast shall be laid on the top of the plinth. the 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand. 69 pipe earthing of 250 / 400 kva medium power transformers 70 net fencing shall be 1150*1200 mm made of 35*35 mm ms angle covered by expended netal 14 swg up to full height 1200 mm duly steftened by ms flat by an 8 swg dia bolt & nut 71 guarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg / 8 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x guards ( tillis ) of gi wire at distance of 3 mtr. 72 fixing and grouting of lt incomming pannel with metering equipments 73 safe dismantling offollowing old & usedt / f and materialwith opening of all connection with safe carriage up to je store / esc hathras ( distance range 0 to 50 km ) 74 100 / 63 / 25 kvat / f from double pole 75 acsr wesal conductor scrape 76 installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the t pole shall be grouted with cement, sand and brick ballast / stone ballast in ratio 1:4:8 including the cost of material. 77 safe dismenteling of old 5 mva t / f from foundation and carriage it from switch yard to out side boundary 78 fixing and grouting with earthing of 11 kv vcb panel 79 construction of plinth suitable for10 mva t / fabove ground level one ft below the ground level of 9 after exavation of 4 earth brick ballast shall be provided and remaining willbe done properly after ballast shall be provideda retaining wall 9width by fist class brick in ratio 1:4 of cement & sand shall be made . the earth shall be filled up to one ft.below the top of the plinth after this brick ballast shall be provided upto 6from the earth level and proper rammering shall be done one no. jall of 12 mm ms tor shall be fixed in the hollow of plinth and one ft. thick rcc in ratio of cement sand & stone ballast shall be laid on the top of the plinth. the 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand. 80 making all h / t / jumpers of installed new / repaired 10 mva t / f after completion of work 81 earthing of 10 mva power t / f ( body & neutral ) 82 cutting, chopping, triming of tree branches to clear the line route to give2 mtr. horizontal and vertical clearance to the line coming in the route ofdifferent feeders as per direction of supervising engineer...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36947057 work of central aayurvedik research institute in deposit scheme under eudd i jhansi 1 safe loading, carriage and unloading of st pole 11 mtr. long from esc hasari store to work site. 2 safe loading, carriage and unloading of line material from esc hasari store to work site. 3 supply of gi pipe 6 dia for cable road crossings, dp structure if not available in store. 4 construction of double pole structure with st pole 11 mtr. long sp 55 including fixing of all accessories complete with concreting & plinth for section pole in 11 kv ug line 5 chemical earthing of 11 kv ug cable & 11 kv vcb panel complete 6 earthing of pole by earthing rod, gi wire etc. complete. 7 erection of stay set complete as per respo manual including their concreting. 8 painting of pole with red oxide paint & aluminum paint and numbering of pole with black over yellow base. 9 digging of cable trench for laying of 11 kv ug cable with first class bricks protection and filling the river sand including back filling by sand complete. 10 erection & commissioning 11 kv vcb panel with adaptor panel and done the energisation with existing incomer. 11 extra pit digging in hard rock / uneven area if any 12 laying of 11 kv xlpe cable of construction of 11 kv line ( double circuit ) 13 filling of cable termination / jointing kit of size 3*120 sqmm 11 kv 14 fabrication ofms angles / channels / cross arm if any. 15 supply & fixing of nut & bolt off size if not available by store. 16 number marking on pole with paint as per norms. 17 chopping & cutting of tree branches....

Kanpur Electricity Supply Co Limited - Uttar Pradesh

36877148 work of replacement of damaged conductor to new dog conductor at koyla nagar substation and replacement of damaged 11 kv vcb panel at sujatganj substation in daheli sujanpur division under the area of e.u.d.c. iii kesco. kanpur...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36872021 approved in the business plan 2023 24, 630 kva bareilly ka madrasa due to overloading of 400 kva transformer at kamela road, duda colony, in the working area of ​​electricity urban distribution division first, saharanpur. work of replacement of dilapidated abc at 250 kva mohalla daud sarai and replacement of 11 kv outgoing vcb panels installed at sub centre ghantaghar....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36725190 for shifting of 33 kv and 11 kv vcb panels of newly constructed control room building and installation of bus coupler and 11 kv vcb for sub station transformer at 33 / 11 kv sub station nauchandi, meerut in the area of eudd iii, meerut....

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36683061 shifting of building under edd rath 2 dismantling charge of 11 kv vcb panel 2 no. incoming & 06 nos outgoing 3 installation charge of 11 kv vcb panel 2 nos incoming & 6 nos outging 4 dismantling of 11 kv s / s kheda power house 02 nos incoming & 6 nos outging switchgear from control room to side of 33 / 11 kv sub station kheda 5 loading of 11 kv s / s kheda power house nos 2 nos incoming & 6 nos outging switchgear on the vehicle by crain & labour etc at 33 / 11 kv sub station kheda 6 cartage of 11 kv kheda power house 2 nos incoming & 6 nos outgoing 33 / 11 kv sub station khedato hamirpur 7 unloading of 11 kv s / s kheda power house 2 nos incoming & 6 nos outgoing 33 / 11 kv switchgear on the vehicle by crain & labour etc at 33 / 11 kv sub station kheda 8 safely loading of new of 11 kv s / s kheda power house 2 nos incoming & 6 nos outgoing 33 / 11 kv vcb on the vehicle by crain & labour etc at 33 / 11 kv sub station kheda 9 cartage of loading of new of 11 kv s / s kheda power house 2 nos incoming & 6 nos outgoing 33 / 11 kv switchgear vcb from esc hamirpur to 33 / 11 kv s / s kheda 10 earthing opening of old vcb & new 11 kv switchgear vcb pannel by welding & nut bolts as per resspo manula. 11 erection of 3x300 sqmm 11 kv xlpe cable 12 erection of 3x185 sqmm 11 kv xlpe cable 13 erection of 11 kv jointing kit cable box i / d 11 kv 3x300 xlpe 14 erection of 11 kv jointing kit cable box o / d 11 kv 3x300 xlpe 15 erection of 11 kv jointing kit cable box i / d 11 kv 185 xlpe 16 erection of 11 kv jointing kit cable box o / d 11 kv 185 xlpe...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36657015 work of business plan agt. passed package / linkage ( 04 nos ) under jurisdiction of edd 4, shamli under edc, shamli 1.01 transportation of 11 meter stp polo from corporation store center or any nearest place to work site including loading and unloading on both sides. distance 0 to 80 km 1.02 pcc from corporation store center to workplace. polo line material conveyance including loading and unloading on both sides. distance 0 to 80 km 1.03 corporation store center or any nearest place to work place ( 3x95 + 1 x 35 + 1 x 16 ) lt. delivery of abc conductor which includes loading and unloading on both sides. 1.04 transportation of 100 kva transformer from nigam store center or any nearest place to work site including loading and unloading on both sides. 1.05 11 m st as per raspo norms. complete work of erecting double pole on polo including installation of all accessories. earthing road as per raspo norms the work of doing tireless. 1.06 1.07 installation of double pole transformer at site as per raspo norms. 1.08 sagging by spreading rabbit / weasel wire at the site as per the norms of raspo. complete work. 1.09 complete work of sagging by spreading lt abc conductor at site ( 3x95+1x35+1x16 ) as per raspa norms. complete work of making all the connections by installing lt distribution box at the site as per the norms of raspo. 1.10 1.11 complete work of installation of stay road as per the norms of raspo. 1.12 11 kv vcb panel from corporation store center or any nearest place to workplace. work of delivery ( distance 0 to 150 km ) work of installation of fuse set as per the norms of respo 1.13 1.14 complete work of installation of 11 kv vcb control panel in control room as per raspo norms. 1.15 11 kv vcb as per raspo norms. earthing work for control panel. grouting of polo as per raspo norms 1.16 , complete work to do | 1.17 , the following material will be payable by the tenderer for the above work. double pole clamp 1.18 grouting material 1.19 distribution box clamp 1.20 | nut bolt 1.21 stay rod clamp 1.22 stay insulator 1.23 stone pad...

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

36389287 works of supply and installation of perishable material in vcb in electricity distribution sub division gola under electricity distribution block gola in the work area of ​​electricity distribution board gola. 1 supply and installation of 11 kv c.t ( current transformer ) double core suitable for metering and protection 600 / 300 / 5 amp. capacity compatible for coronet make 11kv incomer v.c.b. panel in the all material and t&p required for proper completion of the job . 2 supply and installation of 11 kv c.t ( current transformer ) double core suitable for metering and protection 400 / 200 / 5 amp. capacity compatible for coronet make 11kv incomer v.c.b. panel in the all material and t&p required for proper completion of the job . 3 supply and installation of 11 kv vacuum interrupter 110000 / 110 / volt capacities suitable for coronet make 11 kv incomer compactable for coronet make 11kv incomer vcb panel in the all material and t&p required proper completion of the job. 4 gst extra....

Kanpur Electricity Supply Co Limited - Uttar Pradesh

36306538 work of replacement of damaged conductor to new dog conductor at koyla nagar substation and replacement of damaged 11 kv vcb panel at sujatganj substation in daheli sujanpur division under the area of e.u.d.c. iii kesco. kanpur...

Kisan Sahkari Chini Mills Limited - Uttar Pradesh

36161622 supply of transformer vaccum circuit etc , a. vacuums circuit breaker (vcb) 630amp, cassette type closing & tripping coil 230vac, spring charging, motor 220vac, l&t make b. complete vcb panel base mounted with required materials 1. current transformer100/5amp, dual core metering class 05, core 2 protection 03 nos. 2. potential transformer 100va, 11kv s //110vs3, fixed cl 0.5 01 nos. 3. digital ammeter (0 100amp) 01 nos. 4. digital voltmeter (0 11kv) 01 nos. 5. protection relay overload, earth put 01 nos. 6. indicating light r,y,b,on, off, trip, tch, sc – 08 nos. 7. control mcb as required. 8. selector switch (local/remote) 01 nos. 9. push button emergency stop, mushroom head 01 10. breaker control 16amp, 2nc 01 nos. 11. auxiliary contractor 2no + 2nc 01 nos. 12. hooter 01 nos. 13. panel illumination 01 nos. 14. space heater with thermostat 01 nos. , transformer (step down) with testing certificate (specifications) a. phase 3 b. power 630kva c. h.v. 11000 volt d.l.v. 433 volt ± 1% e.hv amp 21amp f.lv amp 537 amp g.frequency 50 h3 h.level two i. vector group dyn 11 j. transformer oil k. copper material used hindalco make l. core material grain oriented electrical steel m. cooling onan n. ambient temp 55 degree c , apfc 500 kvar with 1600 amp. acb a. shd capacito 440v/480v. b. capacitorcontrols. c. automatic function relay. d. 1600 amp. acb installed, draw out, edo,4 pole. e. 16 gauge sheet panel base. f. kwh+vaf meter g. indication of capacitor . h. auto manual operation. i. face indication and phase protection relay. , earthing work with gi electrode....

Kanpur Electricity Supply Co Limited - Uttar Pradesh

35983361 tender for replacement of damaged pole and conductor/ab cable with new pole and ab cable, guarding of line, pipe earthing of distribution transformer, installation of distribution transformer, construction of line, segregation of line, replacement of vcb panel....

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

35935046 work of central aaryuvedic research institiute in deposit scheme under eudd i jhansi 1 safe loading, carriage and unloading of st pole 11 mtr. long from esc hasari store to work site. 2 safe loading, carriage and unloading of line material from esc hasari store to work site. 3 supply of gi pipe 6 dia for cable road crossings, dp structure if not available in store. 4 construction of double pole structure with st pole 11 mtr. long sp 55 including fixing of all accessories complete with concreting & plinth for section pole in 11 kv ug line 5 chemical earthing of 11 kv ug cable & 11 kv vcb panel complete 6 earthing of pole by earthing rod, gi wire etc. complete. 7 erection of stay set complete as per respo manual including their concreting. 8 painting of pole with red oxide paint & aluminum paint and numbering of pole with black over yellow base. 9 digging of cable trench for laying of 11 kv ug cable with first class bricks protection and filling the river sand including back filling by sand complete. 10 erection & commissioning 11 kv vcb panel with adaptor panel and done the energisation with existing incomer. 11 extra pit digging in hard rock / uneven area if any 12 laying of 11 kv xlpe cable of construction of 11 kv line ( double circuit ) 13 filling of cable termination / jointing kit of size 3*120 sqmm 11 kv 14 fabrication ofms angles / channels / cross arm if any. 15 supply & fixing of nut & bolt off size if not available by store. 16 number marking on pole with paint as per norms. 17 chopping & cutting of tree branches....

Military Engineer Services - Uttar Pradesh

35930717 special repair / replacement of ht 11kv ocb with 11kv vcb panel at mes power sub station and replacement of dg set against old u / s ber dg set at 4afsb varanasi under af station gorakhpur...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

35791193 tender for electrification work nagar nikay 2 stp pole ( sp 55 ) 11 mtr long 3 m.s channel, 100x50x2240 mm ( top channel ) 4 m.s.channel ( 125*65*1300 ) mm t off 5 droper channel m.s. 100x50x2000 mm 6 ms angle 75x75x6, 2080mm with clampe & nut bolt ( tf base ) 7 pcc pole 8.5mtr long 8 11kv 3core 185sqmm xlpe cable 9 x arm m.s. angle ( 65*65*6 ) mm v type 11kv 10 11kv disc insulator with fitting ( polymer ) 11 11kv pin insulator with pin &nut 12 100kva 11 / 0.4kv transformer new 13 acsr weseal conductor 14 stay complete 15 earthing complete 16 cross breacing ms angle with clamps, n&b 17 g.i. wire 6swg&10swg for gaurding lacing 18 3 x 185mm2 11 kv xlpe cable o / d jointing kit 19 ab cable ( 3x95+1x70+1x16 ) sqmm 20 200 / 100 / 5a outgoing 11kv vcb panel 21 m.s. gaurding angle ( 65x65x6 mm, 1.6 m long ) for gurding at single support with clamp 22 g.i.pipe 6dia 23 hdpe pipe 6 dia 24 dead end clamp with eye hook ( insulated ) 25 suspen. clamp with eyehook & hold. clamp 26 piercing connectors 16 16 sq.mm 27 piercing connector 95 95 sq.m.m. 28 distribution box 29 distribution box clamp 30 pole clamp with nut & bolt ( in nos ) 31 cross arm holding clamp with bolt & nuts 32 t off, top, dropper clamp with nut&bolt 33 f bracket for 11 kv line 34 nut bolt with washer 35 work of following materials as per resspo / puvvnl norms at the work site. 36 erection of sectional double pole structure of pcc pole including digging of pit, fitting of accessories, back filling of earth, grouting of each pole & stay sets & other required works. 37 erection of sectional double pole structure of stp pole including digging of pit, fitting of accessories, back filling of earth, grouting of each pole & stay sets & other required works. 38 errection of single stp in clay diggingof pit fittings all acessories, grounting of pol 1:4:8 ratio of cement of concrete as per resspo. 39 errection of single pcc in clay diggingof pit fittings all acessories, grounting of pol 1:4:8 ratio of cement of concrete as per resspo. 40 11 kv 3x185 sq mm xlpe cable laying digging of trench size 0.75x0.75 mtr & putting layer of sand of bottam & laying of cable covering the trench from sites & top by laying bricks finely cover the same by earth. 41 making ofjointing kit of cable box size 3x185 mm2 11 kvoutdoor type 42 construction of plinth, foundation & installation of 11 kv vcb 200 / 100 / 5a 43 stringing & sagging oflt line upto proper sag including laying of cable lt abc ( 3x50+1x35+1x16 ) sq mm conductor, binding with insulators & jumpering. 44 stringing of acsr weasel conductor with pin&disc insulator 45 11 kv 3x185 sq mm xlpe cable ( 200 mtr. ) laying digging of trench for ralway crossing, drilling of railway track by hdd machine to cross the railway track by hdpe pipe at robertsganj ( 100x2 mtr ) 46 mounting of distribution box with clamp on pcc pole and connection with piercing connector 47 erection of 100 t / fon double pole s / s base & connection of all accessories...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

35584610 supply of ct for vcb in the area of eutd aligarh , 11kv resin cast c.t. ration 800 / 400 / 5 5 amp. accuracy class 0.5 / 5p10, va 15, feeq 50hz, stc 13.1 ka / 1 sec, isulationlevel 28 / 75 kv as per is 2705, suitable for 11 kv stelmac make vcb panel ( incoming ) , 11kv resin cast c.t. ration 400 / 200 / 5 5 amp. accuracy class 0.5 / 5p10, va 15, feeq 50hz, stc 13.1 ka / 1 sec, isulationlevel 28 / 75 kv as per is 2705, suitable for 11 kv stelmac make vcb panel ( outgoing ) ...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

35551569 tender for installation of vcb panel 2 dismantling of damage 11 kv 01 no incoming & 3 no outgoing switchgear from control room to side of 33 / 11 kv sub station rihuta 3 loading of damage 11 kv 01 no incoming & 3 no outgoing switch gear on the vehicle by crain & labour etc at 33 / 11 kv s / s rihuta 4 cartage of damage 11 kv 01 no incoming & 3 no outgoing from 33 / 11 kv s / s rihuta 5 unloading of damage 11 kv 01 no incoming & 03 no outgoing switchgear on the vehicle by crain & labour etc at esc hamirpur 6 safely loading of new 11 kv 01 no incoming & 3 no outgoing switchgear on the vehicle by crain & labour etc at esc hamirpur 7 cartage of new 11 kv 01 no incoming & 3 no outgoing switchgear from esc hamirpur to 33 / 11 kv s / s rihuta 8 safely loading of new 11 kv 01 no i ncoming & 03 no outgoing switchgear by crain & labour labour etc 33 / 11 kc s / s rihuta 9 shifting carefully and safely new 11 kv 01 no incoming & 3 no outgoing swictchgear in control room with grouting of match switchgear fron of foundation bolt in cc 1:2:4 ration including cutting cc in floor and its finishing as per direction of sidde enginer. includes the work of fixing switchgear on foundation bolt with nut in proper position and aligment and checking complete work as per schedule and resspo drawing. 10 earthing opening of old vcb & new 11 kv switchgear vcb pannel by welding & nut bolt. as per resspo manual...

East Central Railway - Uttar Pradesh

34773463 supply of supply, erection, testing & commissioning of vacuum interrupter suitable for similar to schneider make ht vcb panel ( model vg2 bw524 / 99 / ro, 00 2 kb020048 ) , make : schneider, l&t or similar.supply, erection, testing & commissioning of vacuum interrupter suitable for similar to schneider make ht vcb panel ( model vg2 bw524 / 99 / ro, 00 2 kb020048 ) , make : schneider, l&t or similar., supply, erection, testing & commissioning of vacuum interrupter suitable for similar to schneider make ht vcb panel ( model vg2 bw524 / 99 / ro, 00 2 kb020048 ) , make : schneider, l&t or similar. => limited...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

34655564 supply of ring type ct for protection / metering of vcb panels installed at various sub stations under edc fatehpur , 11 kv ring type c.t. / ratio 800 / 400 5a ( metering / protection burden 15 v.a. and metering accuracy 0.5 / protection accuracy 5 p 10 ) , 11 kv ring type c.t. / ratio 600 / 300 5a ( metering / protection burden 15 v.a. and metering accuracy 0.5 / protection accuracy 5 p 10 ) ...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

34381652 repairing of i / c and o / g vcb under edd deoband 2 repairing & setting of on and off tripping mechanism system together with adjustment of main shaft with replacementof sundary itam such as bus pin washer nut & bolt spring and wiring etc.eith complete cleaning and washing 3 remove of 11 kv vcb panel after disconnecting the connections. 4 instalationand fxing of vcb in panel making of connection with adjustment & proper energisation of vcb in perfect working order. 5 re setting of vaccume interrupter of vcb properly fittinig complete ( 03 sets ) 6 opening of 06 no. bushing rod and refitting the same after cleaning. 7 re setting of male and female fingger contact with cleaning etc. 8 cleaning of carbonized spout assembly bus ans cable box side by including cleaning of vcb panel and bus bar. 9 repairing andfitting of small and big graree from 11 kv vcb. 10 earthling of vcb incoming pannel of boring 60ft deep and fixing of 60ft gi pipe 1.5 inch dia class b and connecting with gi strip of size 40*5 mm at the botten of gi pipe to the t f with providing of required charcoal and salt in the pipe...

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

34338440 repairing and over hauling of 11 kv vcb ( incoming / outgoing panel installed at 33 / 11 kv sub stations in the area of electricity distribution division sandila, hardoi. complete repairing & overhauling 11 kv vcb panel ( incoming / outgoing feeders & repairing of defective damage parts spars electricals mechanical includingrepairing of relay & damage wiring.all cost of labour t&p will be provided by the contractor except vaccume interpreter....

Indian Oil Corporation Limited - Uttar Pradesh

34269627 supply of jyoti make vcb spares jyoti make vcb spares , list of item ( s ) / work ( s ) as per tender documents , closing coil assembly, 110v dc, 4vc49 110 , tripping coil assembly, 110v dc, 4vc49 106 , micro switch ( 1no+1nc ) , jyoti , bkr aux switch, vcb, 1250a, jyoti , mtr, spring charging, f / 6.6kvjyoti vcb , geared spring charge motor, 110v dc , 16 pin plug & socket , closing shaft with spring, ( 4vc49 0069 ) , tripping shaft with spring, ( 4vc49 0051 ) , spur gear assembly, ( 4vc49 0018 ) , jyoti , pinion gear assembly, ( 4vc49 0091 ) , jyoti , charging handle assembly ( 4vc49 0418 ) , trip catch assembly ( 4vc49 0244 ) , jyoti , closing catch assly. ( 4vc49 0150 ) , jyoti , tripcatch w / link assly, 3vc49 0008, jyoti , nut assembly ( 3vb79 073 ) , cam shaft assembly ( 3vc49 0004 ) , u shape barrier, vcb, 1250a, jyoti , crank ( lhs & rhs ) , wipe spring, p / n:4vc47 0194, jyoti , spring, closing, f / 12kv, jyoti vcb , spring, tripping, f / 12kv, jyoti vcb , brkr contct multiplier, 110v dc, 7no+7nc , switch, test posit, 2nc f / ht panel, jyoti , switch, l.r.control w / lock f / htpanel, jyot , tnc switch, 4 way, w / lock &key, 16a, 110vdc , vcb, vk10j25, 630a, 11kv , vcb vk 10m25a, 1250a, 220dc, 12 / 6.6kv, jyoti , vcb, vk10p25, 2000a, 11kv , vcb vk 10m40b, 1250a, c / s220dc, 12kv, jyoti , vacuum interrupter, vk10j25, jyoti , moulded contact shroud, 1vb79 0082 / 01 , coupling for 7.2kv, 3150a vcb , bus conductor upper ( 4vc13 0001 ) vk10j25 , bus conductor lower ( 4vc13 0004 ) vk10j25 , flexible jumper vk10j25, jyoti, 6.6kv , pds assembly, 27, 4vc19 0027 / 01 , insulating stud assy., 05, 3vc19 0007 / 05 , shutter assembly full ( 3vb79 0087 / 02 ) , pole, vacuum interrupter, p / n:10m25 , shrouds, 1250a, vcb, jyoti , coupling, jyoti vcb vk10m25a, 220dc, , busconductruper, jyoti vcb vk10m25a, 220dc , busconductrlowr, jyoti vcb vk10m25a, 220dc , flexible jumper, ( 3vc19 0009 ) , jyoti , pds assembly, 03, 4vc19 0027 / 03 , insul studassy, jyoti vcb vk10m25a, 220dc , vacuum intrupter for 7.2kv, 2ka vcb , moulded contact shroud, 1vb79 0009 / 03 , cplg, 4vc13 0104, f / vcb panel, 6.6kv, jy , upper bus conductor 7.2kv, 2kavcb , lower bus conductor 7.2kv, 2ka vcb , pds assembly, 28, 4vc19 0028 / 01 , insulating stud assy., 07, 3vc19 0007 / 07 , vacuum interrupter, vk10m40a, jyoti , contact, shroud, switchgear panel, jyothi , coupling, vk10m40a, vcb, jyoti, 4 vc 13 0011 , upr bs cond., vk10m40a, vcb, jyt, 4vc13 0002 , lwr bs cond., vk10m40a, vcb, jyt, 4vc13 0005 , flex jumper vcb vk10m40a, jyoti, 6.6kv , pds assly vk10m40a, jyoti, 6.6kv , insulating stud assly.vk10m40a & vk10j25 , vac.int toshiba, jyoti vcb vk10m40b, 220dc , mould cont shrd vcb vk10m40b, jyoti, 6.6kv , coupling jyoti vcb vk10m40b, 220dc , busconductruper, jyoti vcb vk10m40b, 220dc , busconductrlowr, jyoti vcb vk10m40b, 220dc , flex jumper vcb vk10m40b, jyoti, 6.6kv , pds assly vk10m40b, jyoti, 6.6kv , insulating stud assy., 01, 3vc19 0007 / 01 , shuter assy ful, jyoti vcb vk10m40b, 220dc...

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

34254220 remaining civil and electrical work of construction of 33 / 11 kv 2x10 mva gis based substation ghantaghar park, aminabad, lucknow on turnkey basis 1 33 / 11 kv power t / f 10 mva ( transformer provided by department ) 2 33 kv gis panel set scada compatible ( 2 i / c +1 b / c+1 b / r+2 o / g ) 3 11 kv vcb panel scada compatible ( 2 i / c+1 b / c+1 b / r+8 o / g ) 4 33kv l.a 5 33 kv xlpe cable 3x300 sq mm 6 33 kv i / door j / c kit 3x300 sq mm 7 33 kv o / door j / c kit 3x300 sq mm 8 11kv xlpe cable 3x300 sq mm 9 11kv 3x70 sq mm xlpe cable 10 11kv o / door c / j kit 3x300 sq mm 11 11 kv xlpe cable 3x185 sq mm 12 11 kv o / door c / j kit 3x185 sq mm 13 11 kv i / door c / j kit 3x185 sq mm 14 11kv i / door c / j kit 3x300 sq mm 15 11kv end termination c / j kit 3x70sq mm 16 11 / 0.4 kv t / f 63 kva 17 pvc cable 3.5x70 sqmm 18 24 volt battery set with battery charger 19 33kv line isolator 400 a 20 st pole 9 m long 21 cu. cable 6x2.5 sq mm 22 cu. cable 4x2.5 sq mm 23 cu. cable 2x2.5 sq mm 24 ms round bar 32 mm 25 fire extinguisher 26 fire bucket with stand 27 t&p items ( digital megger 11 kv, crimping tool, tongue tester, multi meter, tool box etc. ) 28 laying of single circuit 33 kv 3x300 sq mm xlpe cable in constructed trench and proper dressing. 29 laying of single circuit 11 kv 3x300 sq mm xlpe cable in constructed trench and proper dressing. 30 construction of t / f plinth of size 1.5x1.5x1.0 m on a padding 0.25m deep in ground 1:5:10 cemend sand and brick ballast on the top of padding brick work ist class brick of 0.95 mtr hight & 0.35 mtr wall will be constructed.rest wall should be 0.23 mtr thick.brick work in ratio 1:4 cement & cores sand in the hollow portion the sand should be fiilled from the ground level up to 15 centimeter below from the top of wall, cement, sand & brick ballasts should be filled up to 15 centimeter.two no. of channel 100x50 in length 1500mm will be grouded.0.35 cm.rcc will be done with cores sand, cement and stone ballast in the ratio of 1:2:4.the t / fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand. ( all the material will be arranged by the contractor . ) 31 laying of single circuit lt 3.5x70 sq mm xlpe cable in constructed trench and proper dressing. 32 s / c cable laying in normal soil by digging of trench 900 mm deep, 500 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. ( all thematerial required for laying will be supplied by thecontractor except 11 kv xlpe cable ) 33 s / c cable laying in constructed trench 34 cable laying in ms pipe 125 mm dia 35 cable laying in hdpe pipe 125 mm dia 36 isolator structure fabrication of isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per resspo drawing, with help of m.s channel 125x65 mm two pieces of m.s channel joined to each other by m.s flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. grouting of isolator structure in cc ( cement , coarse sand and stone grit of 20 mm gauge ) including supply of necessary t&p and painting os structure complete. ( all the material shall be arranged by contractor including rail piece ) 37 lightning arrestor structure : fabrication of lightning arrestor / ct structure / pt structureas per resspo drawing with the help of 2 nos m.s channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect. 38 cable stand with d.o arrangement fabrication and erection of cable support made of two pieces of m.s channel 100x50 mm, 4.0 mtr longjoined by 5 nosms flat 50x6 mm fixing of 6 nos 11 kv pin insulator with pin for do arrangement as per drawing and grouting in a block of size 300x300x700 mm complete with painting complete in all respect. 39 earthing by way of boring and lowering of b class gi pipe 50 mm dia from ground upto the water level ( minimum 30 meter deep ) as per standard 40 construction of cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover m.s strip at the interval of 0.30 m and m.s angle at both the edge of the trench and trench cover.iincluding trench cover in 0.5 m length with arrangement of hooks for lifting of cable trench cover in easy and safe manner. 41 fabrication of structures, grouting, plinthing and painting of structures for following equipment. 42 cable stand 43 neutral l bracket 44 providing and fixing of led light for yard lighting ( 8 nos ) 45 supply and fixing lt distribution panel for lighning of control room, switch yard and substation building the panel contaaining 1 no 63 amp mccb and 5 no outgoing mcbs for substaion buliding, yard lighting, ac and dc supply of panels etc. 46 hoisting of 33 kv single cable on existing / erected cable standincluding jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 47 hoisting of 33 kv single cable in 33 kvgis panelincluding jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 48 hoisting of 11kv single cable in 11 kv vcb panelincluding jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 49 hoisting of 11kv single cable outdoor end termination at including jumpering, dressing of cable with required all necessary clamps and nut, bolts pipe etc. ( all the material shall be arranged by contractor ) 50 construction of fire wall, rccframed with fire bricksin between transformers ( 4.5x0.345x4.00 ) mtr 51 price schedule for remaining work of construction of double story switch gear room building cum office and collection centre, boundary wall road drain culvert, tubewell & other associated worksas per annexure 1 52 supply of following auxiliary material 53 office table ( 1200x750x600 mm ) as per standard. 54 providing and fixing executivehigh back chair 55 armed chair 56 providing and fixing of visitor bench 3 seater 57 steel almirah 58 notice board as per norms 59 key board 60 load chart board 61 line chart board 62 s / s board 63 s / s board...

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

33974850 supply of electrical lighting, consumables and misc. items for jtpp supply of electrical lighting, consumables and misc. items for jtpp, malawan, etah , mccb 4 pole 100 amp , mcb 64 amp 4 pole , mcb box wih 04 no.mcb of 32 amp , street light of 90 watt led bulb with complete outdoor fitting , ctr 300 / 5 amp for stelmech make 11 kv panels , 4 sq.mm auto pvc copper wire of 90 m length , 2.5 sq.mm auto pvc copper wire of 90 m length , “d” spanner set dep 8x9 to 30x32make taparia / visko / bizi , ring spanner set 6x7mm to 30x32mm make taparia / visko / bizi , bihexagonal ½ inch squire drive socket set with extension bar 14 mm to 04 mm and t 20, t 25, t 30 &t 40make taparia / visko / bizi , screw driver set 4” to 12”make taparia / visko / bizi , meggar 2500v hand driven make waco / cie / meco , digital clampmeter tong tester 0 500 amp, & 0 600 voltsmake meco / fluke / htc , multimeter a / c / d / c make meco / fluke / htc , earthing line arrester rodisi standards make , phase separator, stelmec make 11kv vcb panelisi standards make , hrc fuse for dry type stelmec make 11 kv vcb panel isi standards make , auto copper pvc wire of 90 meter length, 04 sq.mm ( red, yellow, blue &black colour ) make –havells / polycab / finolex , led bulb 07w make philips / syska / havells , led bulb 09w make philips / syska / havells , street light with fitting 80w led bulb make philips / syska / havells , silica gelisi standards make , 3x300 sq.mm. xlpe cable end jointing kitmake raychem / denson / 3m , distilled water for batteriesisi standards make , h.t.tapeisi standards make , ctr ‘d’ type 300 / 150 / 5 a for stelmec make 11kv vcb panelsisi standards make , ctr ‘d’ type 200 / 100 / 5 a for stelmec make 11kvvcb panelsisi standards make , led bulb for 11kv stelmec make vcb for 11kv panelisi standards make , hrc fuse for 11kv / 110v pt dry type for stelmec vcbisi standards make , single phase, submersible pump starter, 2hpisi standards make , auxiliary contact male for dry type 11kv ptisi standards make , auxiliary contact female for dry type 11kv ptisi standards make , hrc fuse for 11kv dry type pt 3.15aisi standards make...