Revenue Department - Uttar Pradesh

40453363 bids are invited for high quality computer (q3) , ups 650v single phase (q3) , printer cum scanner (q3) , flat scanner (q3) , led tv 50 inch (q3) , video conferencing system (q3) , ac 1.5 ton (q3) , wi fi switch (q3) , switch port 16 (q3) total quantity : 87...

Public Works Department - Uttar Pradesh

28408713 bids are invited for networking & it equipments total quantity : 1 1 switch number of ports and power supply 2 20*10g sfp+ port and additional 4 10gbase t / sfp+ combo ports. 3 should have rj 45 and mini usb console ports for out of band cli management. 4 one 10 / 100 / 1000base t rj 45 ethernet for out of band ip management. 5 one usb port for easy management for images and configuration files, that can be copied to and from the nvram of the switch. 6 one alarm port to provides an external alarm detection. 7 port standards & functions: ieee 802.3 10base t ethernet, ieee 802.3u 100base tx fast ethernet, ieee 802.3ab 1000base t gigabit ethernet, 802.3ae 10 gbe, 802.3an 10gbase t, ieee 802.3x flow control for full duplex mode, auto negotiation 8 should support ieee 802.3az energy efficient ethernet. 9 should support n+1 power redundant mode. two power supply should be supplied with switch and ready from day 1. 10 performance 11 switching capacity should be 480 gbps or more. 12 64 byte packet forwarding rate should be 357 mpps or more. 13 mac address table should be 48k or more. 14 stackability 15 switch should support physical stacking up to 4 units per stack. stacking bandwidth should be up to 80g. 16 switch should have virtual stacking support, up to 32 devices per virtual stack. 17 l2 features 18 should support head of line blocking prevention for lower latency and better performance. 19 support jumbo frame up to 12000 bytes or higher. 20 should support igmp snooping, able to create 500 or more igmp groups and require support for host based igmp snooping fast leave. 21 should support mld snooping, able to create 250 or more mld groups, per vlan mld snooping and require support for host based mld fast leave. 22 should have 802.1d stp, 802.1w rstp and 802.1s mstp spanning tree protocol. 23 should support loop back detection. 24 should support loop guard and root guard. 25 should have erps as per standard itu t g.8032 to provide protection for ethernet traffic in ring topology. 26 should support 802.1ax link aggregation. 27 switch should support iscsi awareness. 28 vlan 29 require ieee 802.1q tagged vlan protocol. technical specification of core switch 30 should support 4k vlan groups and configurable vlan id: 0 to 4094 vids 31 should support port based vlan, 802.1v vlan, double vlan ( q in q ) , portbased q in q, selective q in q, mac based vlan, subnet based vlan, private vlan, ism vlan ( multicast vlan ) , voice vlan, auto surveilliance vlan, vlan trunking and garp vlan registration protocol. 32 layer 3 features 33 should supports 256 ip interfaces. 34 should support loopback interface. 35 should support rfc826 arp and rfc1072 arp proxy. 36 should support ipv6 neighbor discovery ( nd ) . 37 should support vrrpv2 and v3. 38 should have 4k hardware routing entries for ipv4 / ipv6. 39 should support static route, default route, rip and policy based route ( pbr ) for ipv4 and ipv6. 40 should support graceful restart ( gr ) helper. 41 should suppoort static, isatap, gre and 6to4 ipv6 tunneling. 42 should support ospf for ipv4 and ipv6. 43 should support igmpv1 / v2 / v3 for layer 3 multicast. 44 should support dvmrpv3 for layer 3 multicast. 45 should support pim dm / sm / sm v6 / ssm / sdm for layer 3 multicast. 46 quality of service ( qos ) 47 should support 802.1p quality of service with 8 queues per port. 48 should support queue handling with strict priority queue, weighted round robin, deficit round robin ( drr ) , spq + wrr and weighted deficit round robin ( wdrr ) . 49 should support qos based on 802.1p priority queues, mac address, ip address, ipv6 traffic class, ipv6 flow label, dscp, vlan, tcp / udp port, tos / ip preference, switch port, ethertype and protocol type. 50 should support trtcm and srtcm three color marker. 51 should support 802.1qaz enhanced transmission selection ( ets ) , 802.1qbb priority based flow control ( pfc ) and 802.1qau congestion notification ( cn ) . 52 access control list ( acl ) 53 should support ingress and egress acl. 54 should support access control list based on 802.1p priority, protocol type, mac address, vlan, ether type, tcp / udp port number, dscp, ip address, ipv6 traffic class and ipv6 flow label. 55 should support time based acl. 56 security 57 should have port security with 12k or higher mac addresses per port. 58 support per port broadcast / multicast / unicast storm control. 59 require dynamic arp inspection and arp spoofing prevention. 60 should support dhcp server screening. 61 should have ssh and ssl for ipv4 and ipv6. 62 require prevention of dos attacks, which include land, blat, tcp null scan, tcp synfin, ping of death attack and tcp tiny fragment attack. 63 support traffic segmentation to limit traffic flow from a single or group of ports, to a another group of ports. 64 should have ip+mac+port binding to restrict the access to a switch. 65 should support dhcpv6 guard, ipv6 route advertisement ( ra ) guard and ipv6 nd inspection. 66 should support duplicate address detection ( dad ) . 67 should support bpdu attack protection. 68 should support compound authentication with multiple option, which should include 802.1x port based, 802.1x host based, wac and mac for access control. 69 should support radius and tacacs+ authentication with authentication database failover. 70 should support support 802.1x nap. 71 management 72 able to manage trough web gui, fully functional cli interface and telnet. 73 should support snmp v1, v2c, v3 and snmp traps and rmon v1 and rmon v2. 74 should have multiple image and configuration file support to reduced down time for the switches. 75 should support cable diagnostics to test copper cables and determine the quality of the cables and the types of error. 76 should support 802.3ah ethernet link oam and 802.1ag connectivity fault management ( cfm ) and y.1731 oam. 77 should support sflow ( rfc3176 ) for monitoring traffic in data networks. 78 should have sntp / ntp protocol for time synchronization. 79 should have ipv4 / v6 dual stack. 80 should support lldp and lldp med. 81 physical / environmental 82 ac input: 100 to 240 vac, 50 / 60 hz internal universal power supply 83 operating temperature: 5 to 50 ˚c ( 41 to 122 ˚f ) 84 certifications: ce, fcc, c tick, vcci, bsmi, ccc 85 safety: cul, cb, ce, ccc, bsmi 86 switch should be supplied with the all necessary hardware accessories like power cord, rack mount bracket, installation guide, etc. and necessary software image file to fulfill all above mention feature set from day 1. 87 make ruckus / aruba / d link 88 make should be mentioned while submitting the tender. 89 authorization letter from oem should be provide while submitting the tender...

Indian Coast Guard - Uttar Pradesh

27609288 procurement of acv auxiliary ard 2020 spares , acv auxiliary ard 20 spares , nut nyloc m10a2 , sikaflex white 300ml , rivet 4 . 8 x 18 mm , rivet pop 4 . 8 x 23 . 5 mm , sikaflex 221 ( black ) , strut forward straight , strut standard , strut stn 2800 inboard , strut stn 18190 inboard , strut aft angled , strut vertical , strut aft angled , layshaft flange ( drwg 80 3 3 ) , propeller driver pulley ( drwg 80 3 04 no . 17 ) , propeller layshaft bearing sleeve nut and tab washer , lay shaft c/w with two keys , taperlock bush 2517x60 , 8mm large mouth rapid link , drive belt , pintle assy , 1570 mm hose assembly 1 . fittings @ 90 degree , 1600 mm hose assembly 2 . fittings @ 90 degree , 6800 mm propeller pitch hose assembly 5 , 7170 mm propeller pitch hose assembly 7 . fittings @ , 8510 mm propeller pitch hose assembly 8 , 6850 mm propeller pitch hose assembly 9 , 4630 mm steering hose assembly 4 , 1420 mm steering hose assembly 9 . fittings @ 270 degree , 6210 mm steering hose assembly 10 . fittings @ 270 degree , 3530 mm steering hose assembly 11 , pulley 50 tooth lift fan driver , transmission pulley propeller driven , universal joint repair kit , centaflex adopter plate , 2830 mm skirt hose assembly 1 . bulkhead ram . port ( h0021804 ) , 3010 mm skirt hose assembly 2 . bulkhead ram , port ( h0021805 ) , 4130 mm skirt shift assembly 4 . bulkhead ram . stbd ( h0021807 ) , propeller drive belt , 1520 mm hose assembly 3 . fittings @ 110 degree , 4710 mm steering hose assembly 5 . fittings @ 180 degree , pulley lift fan driven 60 tooth 14mm pitch , 4020mm skirt shift hose assy 3 bulkhead ram , bearing locating ring 55mm ( spacer ) , st/st rod end rh male m16 gar hw16rr , st/st rod end lh male m16 gar hw12rr , pressure gauge 1/4 bsp 63mm 0 . 40 bar bottom entry , propellet pitch change link , skirt loop material ( pennel orca 258619 ) , skirt outer loop with ap diaphragm 8000td 80 6 10 ghl , rear inner loop , outer loop , metal oval hatch , bridge plate 316m6x30ws 60x30pl , 16 mm mailon rapidlink large mouth , bearing taper roller ( 32020x ) , rod end m 12 ( sme 45 . 12 ) , bearing taper roller , 22313ek skf bearing , eriks tpe r seal ( 85x120x12 ) 316 st/st , eriks type r seal ( 120x160x12 ) 316 st/st , seal kit double lip tsna 313 , centaflux coupling ( cf a 90 g 1 1 60 l=240 , fwd lift fan bearing , aft lift fan bearing , taperlock bush aft lift fan ( 55mm dia ) 3525 55 , bearing ( stub axle aft ) 6310 , bearing ( stub axle fwd ) 6212 , key 14x100 , key 14x70 , key 14x150 , mobile grease xhp 400 g cartridge ( note:moq box of 12 ) use hydr 0347 , lift fan shaft seal forward , water temp . gauge , module low hyd oil , circuit breaker 62a 2pole , fuse gsa 125a , battery radio 12v 25 ahq dry fit type maintenance free , sensor 600mm w ballast , sender/ switch pressure 360 081 030 009 , smoke detector optical+remote , battery charger 24v 50 amp , oil tamperature gauge a2c59514160 , condensor cooling fan , main supply isol;ator 24 dc coil blue seas 7703100b , rediator flap actuator servo motor ( 24 v ) , loud hailer horn pa 60/40 , strip led , joy stick steering , rod end m8 , rod end m8 lh , drive belt apu , pyrogen mag 4 , oil pressure gauge 0 10 bar ( 0 145 psi ) , voltmeter 24v n02410911 , steering pump p11a 193pa/107 as14 96 , stop solenoid 12v , radar display tracker ball , inner loop , m6 penny washer , pyrogen mag 5 , 9060 mm steering hose assembly 1 . fittings @ 270 degree , 3660 mm steering hose assembly 3 . fittings @ 310 degree , 1265 mm steering hose assembly , 1270 mm steering hose assembly 12 , washer pain m16 st/st form a , axilock s ( type iv nbr dia 50 . 5 mm ) , 8mm key pin shackle , bilge pump manual , em2 control pcb , line mounted relief valve rv10 26c3b n 15 , bush delrin rudder/ elevator ( 80 4 2 rev2/13 ) , rudder bush , kit overhaul gasket , feedback unit ( rudder system ) , water temp sensor switch , fuel injector , cold skirt curing agent ( make alpha ) , cold skirt bonding agent ( make alpha ) , skirt shift restrain chain , round inspection hatch , fuel sensor , hydrojet lp system valve , radiator flap temp switch ( port ) fw murphy tulsa usa , vibration sensor monitron , seal lay shaft plummer block fwd/aft...

Directorate of Training and Employment - Uttar Pradesh

18657625 supply of raw material and tool and equipment 17.09 battery storage lead acid 6 v & 12 v 17.1 maintenance free battery 17.11 hydrometer 17.12 battery charger 17.13 rheostats variable values variable resistance 17.14 podium stand 17.15 intractive bord 17.16 pri fy router 17.17 lan cable switch port switch 24 17.18 17.19 ups 5 kva with battery 17.2 variable resistance potentiometer 17.21 dc& ac ammeter 0 50 ma (table model for lab experiment) 17.22 dc& ac ammeter 0 500 ma (table model for lab experiment) 17.23 dc& ac ammeter 0 1 ma (table model for lab expreriments) 17.24 dc& ac ammeter 0 1 a (table model for lab expreriments) 17.25 analog multimeter 17.26 lcr meter 17.27 20 mhz dual trace oscilloscope 17.28 function generator 17.29 pulse generator 17.3 lug bords for circuit wiring 17.31 0 30 v, 2 amp regulated dc power supply 17.32 smps of pc 17.33 pc pentium iv or latest configuration( for lesting with smps ) 17.34 ups 500 va 17.35 printer laser (b& w ) branded 17.36 transformer 0 12 v , 6 0 6 v , 1 amp 17.37 rubber gloves 17.38 pcb solder flux etc & electronic components 17.39 wires, cables plug sokets switches of various types and other consumables 17.4 resistors capacitors inductors diodes transistors thyristors ics etc 17.41 spare transformers and power devices required for servicing smps 17.42 various types of button cell 17.43 laser printer with colour a4 size 17.44 stool 450 mm wooden (aam kib lakdi) 17.45 locker 4 draver 20 swg 17.46 locker 6 draver 20 swg 17.47 locker 8 draver 20 swg locker 12 draver 20 swd 17.48 17.49 locker 16 draver 20 swg 17.5 with different types of meters /switches ac/ dc supplies etc required for testing of electronic circuits insulation mats to cover below the table 17.51 green glass bord 4x3x.5 feet 17.52 metal rack 17.53 book shelf ( glass panel) 17.54 fire fighting equipment first aid box etc. ...

Micro Small And Medium Enterprises - Uttar Pradesh

8402709 supply of hydraulics lab, pneumatics lab, automation laboratory basic, ccna laboratory ( cisco router, switch, port, ethernet wireless device etc, plc laboratory ( standalone plc with power supply, di, do, im cards, mounting din rail ) etc....