North Eastern Railways - Uttar Pradesh

40834665 tender for fire safety audit and design & development of emergency evacuation plan along with specialized fire safety training at coaching depot / cpr, bui, amh, bcy, gct & mau and adjoining locations....

Northern Railway - Uttar Pradesh

40718444 supply of electrical work for conducting electrical safety audit at be,hw and mb railway stations of moradabad division.electrical work for conducting electrical safety audit at be,hw and mb railway stations of moradabad division.,...

Private Company - Uttar Pradesh

40705815 tender for rcc strengthening and structural retrofitting works based on iit roorkee, safety audit report for unihomes phase 3 (uniworld gardens): a1, a2, a3 & a4; b1 & b2 of [g+13] at sector 117, noida. noida sector 117: phase 3 {uniworld gardens}: rcc strengthening and structural retrofitting works for 6 buildings of (g+13) etc. complete as per structural safety audit report by iit roorkee, roorkee....

Private Company - Uttar Pradesh

40705788 tender for rcc strengthening and structural retrofitting works based on iit roorkee, safety audit report for unihomes phase 2: d1, d2, d3, d4, d5, e1, e2, e3, f5 & f6, sector 117, noida....

Private Company - Uttar Pradesh

40705650 tender for structural retrofitting based on structural safety audit by iit roorkee for verve, greater noida, structural retrofitting based on structural safety audit by iit roorkee for verve, greater noida...

Ministry Of Power - Uttar Pradesh

39196142 bids are invited for custom bid for services external safety audit of dadri thermal gas solar plant including fgddsi for 2023 24...

Indian Bank - Uttar Pradesh

38777670 tender for engagement of agency from the empanelled electrical contractors for doing electrical safety audit & energy audit of bank’s branches / office premises under zonal office meerut 1. whether tpn isolators / mccbs / elcbs / are provided to cater the load yes / no 2. whether lights and emergency lights are provided in electrical room / operating are as for easy operation & maintenance works yes / no 3. whether pump room, dgset room, ups room, ac plant room, electrical panel room are maintained in dry and in good condition and obsolete / hazardous / old items are not dumped there. yes / no 4. whether water seepage is observed near any of the electrical panel, distribution board, electrical eqipment, etc yes / no 5. whether earthing pits are provided and connected to equipment and the body of equipment yes / no 6. whether earthing pits are maintained properly yes / no 7. whether exhaust fans for ventilation of panel room / electrical room / ups room / dg set room is provided and no paper, old material or any other scrap is kept near db / panels /ups / batteries etc. yes / no 8. whether penalty is being imposed in electricity bill on account ofhigher load / poor power factor / poor load factor etc (acertained from the elecricity bills of april / may / june / july) additional electrical load required (if any) yes / no 9. whether load is distributed in all three phases to avoid any unbalancing of phase load and no loose electrical connections / haphazrad wirings observedin the building / office premises. yes / no 10. whether isolating switches are provided for switching off of the non essential loads in premises during night and main switch to switch off the power supply to the building / floor incase offire / emergency. yes / no 11. whether proper preventive main tenance after opening of the electriacl boards and distribution boards are carried out by the license holder electrician or skilled technicians of equipment manufacturer / service providers. yes / no 12 whether appropriate timers used in the changeover of airconditioners for server room acs and for signage boards to make auto on / off (for schedule timings). the thermostat of the acs at server room should be set to say 26 c, so that it will run only when the temprature is too high (to minimize chances of fire due to idle running of the acs during night) yes / no 13 whether preventive maintenance of the electric installtion and equipment is carried out by skilled license holder electricians / skilled technicians yes / no 14 general condition of electrical control panels, main switch, electric meter board, change over switch, ac,water coolers, water filters, wiring cables etc are in good conditions and dbs, panels, switch boards are properlycovered yes / no 15 whether electrical equipments of pantry etc are properly connected to industrial socket box with mcbs. mcbs or latest type switches are provided to swtich on / off the acs to protect them from over load. yes / no 16 whether the contact number of persons, eletricians, power distribution company. genertor service provider, ups vendors, acs etc are available with security gaurds and other staff are displayed in elctric / ups / serverroom. yes / no 17 whether power factor correctionpanel ofappropriateratingisinstalled. yes / no 18 whether allthe connecting point atvarious dbs andpanels areproperlyinsulatedand proper indicative markingaredonearethe respectivepanel/db yes / no 19. whether the internal insulation of the wire havebeen accountedfor checking the durabilityofelectrical connection yes / no 1. all old disposable records, broken furniture etc accumulated in the premises have been cleared. yes / no 2. combustible leaf litter /waste papers etc in and around the branch are removed /cleaned periodically yes / no 3. no stationary / records/ old obsolete items are stored/kept in the server/ups /electric room yes / no 4. storage racks in stationary / record room kept at a safe distance of at least 2 m from electrical points/switch /junction boxes yes / no 5. whether in the pantry/canteen,lpg is used yes / no fire preventive measures: 6. are the fire extinguishers available in the following work area and clearly marked and accessible: 1.server / ups room: co2 type x 2 2. individual department of the premises:co2 type x 1 3.stationary room: co2 type x 1 4.electric room / ac plant room: co2 type x 2 5.dgset / generator : 6kg abc capacity x 2 yes / no 1. whether server room have dual ac units with timer circuit device on independent circuits yes/no 2. whether exhaust fans are installed in ups room yes/no 3. whether proper insulation at the batteries have been provided yes/no...

Indian Bank - Uttar Pradesh

38319654 tender for engagement of agency for doing electrical safety audit and energy audit of bank branches/ office premises....

Indian Bank - Uttar Pradesh

38319630 tender for engagement of agency for doing electrical safety audit & energy audit of bank’s branches / office premises...

Indian Bank - Uttar Pradesh

38187221 tender document for engagement of agency for doing electrical safety audit & energy audit of banks branches / office premises...

Indian Bank - Uttar Pradesh

38053549 tender for engagement of agency for doing electrical safety audit & energy audit of banks branches / office premises...

Public Works Department - Uttar Pradesh

37916629 1 improvement work according to the road safety audit recommandation report of the black spot by iit delhi in the year 2019 marked black spot in km 10 of lalukheri sisoli fugana road (bs 84 katar singh ki murti) in district muzaffarnagar...

Public Works Department - Uttar Pradesh

37913226 1 improvement work according to the road safety audit recommendation report of the black spot by iit delhi in the year 2019 marked black spot in km 10 of lalukheri sisoli fugana road bs 84/katar singh ki murti in district muzaffarnagar...

Public Works Department - Uttar Pradesh

37876115 according to the recommendations of the road safety audit of the year 2016, 2018, 2019 and 2020, the district pratapgarh, short term improvement work of the identified black spot at km 59 of ghuisarnath atheha azara marg (sh 110)...

Indian Bank - Uttar Pradesh

37609236 tender for engagement of agency for doing electrical safety audit &energy audit of banks branches/office premises...

Indian Bank - Uttar Pradesh

37459373 tender for engagement of agency for doing electrical safety audit & energy audit of bank’s branches / office premises....

Indian Bank - Uttar Pradesh

37386541 tender for engagement of agency for doing electrical safety audit & energy audit of bank’s branches / office premises under zo varanasi...

Ministry Of Petroleum And Natural Gas - Uttar Pradesh

37292466 bids are invited for electrician for manning three shifts & for general shifts (q) , un skilled labor for assitnace job during safety audit, elect audit, visit of statutory bodiees, ea (q3) , providing additional electrician technician support services during safety audit, elect audit, visi (q3) total quantity : 3...

Ministry Of Petroleum And Natural Gas - Uttar Pradesh

37162800 bids are invited for safety audit of cgd gas mse exemption for turnover yes startup exemption for turnover yes additional doc 1 (requested in atc) *in case any bidder is seeking exemption from experience safety audit up uk cluster , safety audit of wb cluster , safety audit of js cluster , safety audit of ahmedbad cluster total quantity : 22...

Public Works Department - Uttar Pradesh

37100227 tender for short term improvement work as per the recommendations of road safety audit on black spot bhitia chauraha year 2020 marked on pubb marg sh 26 in basti...

Public Works Department - Uttar Pradesh

36745841 protective work on black spot number bs 164 349 as per the recommendations of safety audit of black spots by iit bhu in kanpur nagar city portion...

Public Works Department - Uttar Pradesh

36644178 according to the recommendations of safety audit of spot by iit bhu near raha village krishna dhaba pgb marg sh 46 in district kanpur nagar, protective work on black spot no. bs 171....

Institute Of Chartered Accountants Of India - Uttar Pradesh

35377239 tender for appointment of architect/ structural consultant for services of structural safety audit report along with the detailed boq of re strengthening, restructuring, retrofitting/ renovation, remaining life of existing building, repairing including interior works, replacement of goods, lifts etc. or any type of other maintenance, whichever is required as per authorities’ norms of the building at c 1, sector 1, noida....