Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37599971 tender for electrification work, 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long/st pole 11 mtr long 3 lt ab cable 3x120+1x70+1x16 4 lt ab cable 3x95+1x70+1x16 5 lt ab cable 3x50+1x35+1x16 6 63/100 kva t/f 7 3 phase lt distribution box 8 acsr weasal/dog conductor 9 11 kv vcb o/g ctr 200/100/5 a, 35 mva 10 3x185 sq.mm xlpe cable 11 line material as such earthing rod, stay set, stone pad, ms angle, ms channel, piercing clamp, dead clamp, pin insulator, disc insulator, j hook etc, 12 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 13 pcc pole 8.5 mtr long/st pole 11 mtr long 14 lt ab cable 3x120+1x70+1x16 15 lt ab cable 3x95+1x70+1x16 16 lt ab cable 3x50+1x35+1x16 17 63/100 kva t/f 18 3 phase lt distribution box 19 acsr weasal/dog conductor 20 11 kv vcb o/g ctr 200/100/5 a, 35 mva 21 3x185 sq.mm xlpe cable 22 line material as such earthing rod, stay set, stone pad, ms angle, ms channel, piercing clamp, dead clamp, pin insulator, disc insulator, j hook etc, 23 erection of pcc pole 8.5 mtr/st pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 24 erection of double pole on pcc pole 8.5/st pole 11 mtr long after digging a pit of size1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 25 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 26 fixing of lt accessories 27 mounting of 63/100 kva t/f with proper jumpering of ht side and fixing of cable on lt side of t/f. 28 providing and fixing of suspension clamp, holding clamp & lt clamp 29 removing of old acsr weasal 30 laying, stringing & proper sagging of acsr weasal/dog conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 31 earthing of each 11 kv line and t/fproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 32 grouting of pcc/st pole 33 providing and fixing of ms nut & bolts off size 34 providing and fixing of 11 kv fuse set 35 lt ab cable 3x120+1x70+1x16 36 lt ab cable 3x95+1x70+1x16 37 lt ab cable 3x50+1x35+1x16 38 installation of vcb for o/g ctr 200/100/5a, 35 mva 39 laying of xlpe cable 3x185 sq.mm 40 providing and fixing of jointing kit 3x185 sq.mm xlpe cable outdoor 41 providing and fixing of jointing kit 3x185 sq.mm xlpe cable indoor 42 back cartage old and damage acsr weasal conductor 43 back cartage st pole old and used...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37297221 releasing of new connection and construction of ht / lt line applied in jhatpat / nivesh mitra portal consumer ( running contract under deposit scheme ) in the area of edsd i / ii / iii, baghpat road / partapur / kazipur under jurisdiction of edd i, meerut 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / stp pole 11 mtr. long. 3 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 4 25 kva to 100 kva t / f including complete related material required for transformer. 5 xlpe cable of size 3x70 and 3x185 sq.mm 6 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 7 pcc pole 8.5 mtr long / stp pole 11 mtr. long. 8 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 9 25 kva to 100 kva t / f including complete related material required for transformer. 10 xlpe cable of size 3x70 and 3x185 sq.mm 11 erection of pcc pole 8.5 mtr long / stp pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 12 fabrication and fixing of all 11 kv ht / lt line accessories. 13 erection of double pole on pcc pole 8.5 mtr / stp pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 14 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators on d / p pole. 15 mounting of 25 to 100 kva t / f with proper jumpering of ht side and fixing of cable on lt side of t / f. 16 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 17 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 18 laying lifting stringing & proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 19 laying of lt abc cable of various size including fixing of all lt abc accessories on support 20 laying of xlpe cable of size 3x70 and 3x185 sq.mm pit of the size 1.5 in the trench and road crossing in the air 21 fixing of distribution box including fixing the cable from transformar and consumer service cable 22 earthing of each 11 kv line pole & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 23 guarding of line with g.i. wire having 2 no. horizontal wire & 3 mtr distance of swg g.i. wire after fabrication of guard cross arms of & fixing the same in supports. 24 11 kv jointing kit indoor / outdoor of size 3x70 and 3x185 sq.mm 25 providing and fixing of holding clamp 26 providing and fixing of lt clamp 27 providing and fixing of j hook 28 providing and fixing of piercing clamp 29 providing and fixing of dead and clamp 30 providing and fixing of ms nut and bolts 31 providing and fixing of lt insulator 32 cutting & chopping tree branches near side of line for making the clearance between line and tree....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37288678 tender for electrification work, 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / stp pole 11 mtr. long 3 lt ab cable 3x120+1x70+1x16 4 3 phase lt distribution box 5 acsr weasal conductor 6 line material such as stay set, piercing clamp, dead clamp, earthing rod, pin insulator, x arm etc. 7 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 8 pcc pole 8.5 mtr long / stp pole 11 mtr. long 9 lt ab cable 3x120+1x70+1x16 10 3 phase lt distribution box 11 acsr weasal conductor 12 line material such as stay set, piercing clamp, dead clamp, earthing rod, pin insulator, x arm etc. 13 erection of pcc pole 8.5 mtr / stp pole 11 mtr. long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 14 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 15 grouting of pcc / stp pole 16 fixing of lt accessories 17 providing and fixing of suspension clamp & j hook 18 dismentling of old acsr weasal conductor 19 dismentling of old ab conductor 3x120 sq.mm old & used 20 dismentling of st pole old and used 21 laying, stringing & proper sagging of acsr weasal conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 22 earthing of each 11 kv lineproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 23 laying, lifting of lt ab cable of size 3x120+1x70+1x16 24 fixing of distribution box 25 back cartage old and used acsr weasal conductor 26 back cartage old and used st pole 27 back cartage old and used lt ab cable of size 3x120 sq.mm...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37288603 tender for electrification work, loading, unloading of cartridge , 2 pcc pole 8.5 mtr long / st pole 11 mtr long 3 lt ab cable 3x120+1x70+1x16 4 lt ab cable 3x95+1x70+1x16 5 lt ab cable 3x50+1x35+1x16 6 63 / 100 kva t / f 7 3 phase lt distribution box 8 acsr weasal / dog conductor 9 11 kv vcb o / g ctr 200 / 100 / 5 a, 35 mva 10 3x185 sq.mm xlpe cable 11 line material as such earthing rod, stay set, stone pad, ms angle, ms channel, piercing clamp, dead clamp, pin insulator, disc insulator, j hook etc, 12 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 13 pcc pole 8.5 mtr long / st pole 11 mtr long 14 lt ab cable 3x120+1x70+1x16 15 lt ab cable 3x95+1x70+1x16 16 lt ab cable 3x50+1x35+1x16 17 63 / 100 kva t / f 18 3 phase lt distribution box 19 acsr weasal / dog conductor 20 11 kv vcb o / g ctr 200 / 100 / 5 a, 35 mva 21 3x185 sq.mm xlpe cable 22 line material as such earthing rod, stay set, stone pad, ms angle, ms channel, piercing clamp, dead clamp, pin insulator, disc insulator, j hook etc, 23 erection of pcc pole 8.5 mtr / st pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 24 erection of double pole on pcc pole 8.5 / st pole 11 mtr long after digging a pit of size1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 25 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 26 fixing of lt accessories 27 mounting of 63 / 100 kva t / f with proper jumpering of ht side and fixing of cable on lt side of t / f. 28 providing and fixing of suspension clamp, holding clamp & lt clamp 29 removing of old acsr weasal 30 laying, stringing & proper sagging of acsr weasal / dog conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 31 earthing of each 11 kv line and t / fproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 32 grouting of pcc / st pole 33 providing and fixing of ms nut & bolts off size 34 providing and fixing of 11 kv fuse set 35 lt ab cable 3x120+1x70+1x16 36 lt ab cable 3x95+1x70+1x16 37 lt ab cable 3x50+1x35+1x16 38 installation of vcb for o / g ctr 200 / 100 / 5a, 35 mva 39 laying of xlpe cable 3x185 sq.mm 40 providing and fixing of jointing kit 3x185 sq.mm xlpe cable outdoor 41 providing and fixing of jointing kit 3x185 sq.mm xlpe cable indoor 42 back cartage old and damage acsr weasal conductor 43 back cartage st pole old and used...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37205258 regarding running tender for new connection on jhatpat portalfull deposit work scheme and sansad nidhi / vidhayak nidhi depositwork in the area of edsd ii, sardhana dehatunder edd ii, meerut, under edc 2 meerut. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. :– 2 a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 3 cartage of line material from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 20 km. ( 15 qtl. ) 4 cartage of 10 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site 5 cartage of following material from je store to site of work including loading & unloading at both ends maximum distance up to 40 km. :– a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 6 dissmentling of damaged & broken p.c.c. / s.t.pole / r.s. joist by digging the pits & removel of complete h.t. / l.t. line accessories . 7 eartingh of each 11 kv line pople & t / f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 8 erection ofpcc pole 8.5 mtr long / stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 9 fabrication and fixing of all 11 kv h.t / l.t. line accessories. 10 erection of double pole on pcc pole 8.5 mtr after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators and making connection properly. 11 mounting of 10 to 100 kva t / f with proper jumping of ht side and fixing of cable on lt. side of t / f making connection properly. 12 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 13 erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 14 laying lifting stringing of proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 15 laying lifting stringing of proper sagging of acsr rabbit conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 16 laying lifting & sagging of lt line with a.b.c bunch conductor including proper binding & jumpring: a ) 3 phase 4 wire line. 17 grouting of pcc / st poles with dust, cement & stone blast concreting. 18 cutting & chopping tree branches near side of line for making the clearance between line and tree ( near about 100 branches ) . 19 fixing of lt distribution box along with providing clamp nut & bolts 20 providing and fixing stay clamps . 21 providing and fixing f clamp 22 providing and fixing holding clamp 23 providing and fixing lt clamps . 24 providing and fixing ltinsulator clamps . 25 providing and fixing bolt and nuts ....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37205215 regarding running tender for new connection on jhatpat portalfull deposit work scheme and sansad nidhi / vidhayak nidhi depositwork in the area of edsd ii, sardhana townunder edd ii, meerut, under edc 2 meerut 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. :– 2 a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 3 cartage of line material from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 20 km. ( 15 qtl. ) 4 cartage of 10 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site 5 cartage of following material from je store to site of work including loading & unloading at both ends maximum distance up to 40 km. :– a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 6 dissmentling of damaged & broken p.c.c. / s.t.pole / r.s. joist by digging the pits & removel of complete h.t. / l.t. line accessories . 7 eartingh of each 11 kv line pople & t / f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 8 erection ofpcc pole 8.5 mtr long / stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 9 fabrication and fixing of all 11 kv h.t / l.t. line accessories. 10 erection of double pole on pcc pole 8.5 mtr after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators and making connection properly. 11 mounting of 10 to 100 kva t / f with proper jumping of ht side and fixing of cable on lt. side of t / f making connection properly. 12 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 13 erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 14 laying lifting stringing of proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 15 laying lifting stringing of proper sagging of acsr rabbit conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 16 laying lifting & sagging of lt line with a.b.c bunch conductor including proper binding & jumpring: a ) 3 phase 4 wire line. 17 grouting of pcc / st poles with dust, cement & stone blast concreting. 18 cutting & chopping tree branches near side of line for making the clearance between line and tree ( near about 100 branches ) . 19 fixing of lt distribution box along with providing clamp nut & bolts 20 providing and fixing stay clamps . 21 providing and fixing f clamp 22 providing and fixing holding clamp 23 providing and fixing lt clamps . 24 providing and fixing ltinsulator clamps . 25 providing and fixing bolt and nuts ....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37143251 system improvement plan at various places fed from 33 / 11 kv power sub station gagol i and mohiuddinpur in the work area of ​​subdivision i baghpat road and subdivision ii paratapur under power distribution division i meerut ( business plan year 2023 24 ) 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / st pole 11 mtr long 3 lt ab cable 3x95+1x70+1x16 4 lt ab cable 3x50+1x35+1x16 5 25 / 63 / 100 kva t / f 6 3 phase lt distribution box 7 acsr weasal conductor 8 line material as such stay set, pin insulator, disc insulator, earthing rod, gi wire, ms angle, ms channel, top channel, dropper channel, dead clamp, piercing clamp etc. 9 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 10 pcc pole 8.5 mtr long / st pole 11 mtr long 11 lt ab cable 3x95+1x70+1x16 12 lt ab cable 3x50+1x35+1x16 13 25 / 63 / 100 kva t / f 14 3 phase lt distribution box 15 acsr weasal conductor 16 line material as such stay set, pin insulator, disc insulator, earthing rod, gi wire, ms angle, ms channel, top channel, dropper channel, dead clamp, piercing clamp etc. 17 erection of pcc pole 8.5 mtr / st pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 18 erection of double pole on pcc pole 8.5 / st pole 11 mtr long after digging a pit of size1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 19 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 20 fixing of lt accessories 21 mounting of 25 / 63 / 100 kva t / f with proper jumpering of ht side and fixing of cable on lt side of t / f. 22 providing and fixing of suspension clamp, holding clamp & lt clamp 23 removing of old acsr weasal 24 laying, stringing & proper sagging of acsr weasal conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 25 earthing of each 11 kv line and t / fproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 26 removing of 63 kva t / f from double pole 27 grouting of pcc / st pole 28 providing and fixing of ms nut & bolts off size 29 laying, lifting of lt ab cable of size 3x95+1x70+1x16 30 laying, lifting of lt ab cable of size3x50+1x35+1x16 31 back cartage old and damage acsr weasal conductor 32 back cartage 63 kva t / f from site to central store meerut...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37119064 tender for power distribution division i, subdivision i baghpat road and subdivision ii under meerut. work under business plan year 2023 24 at various places fed by 33 / 11 kv power sub station gagol first and mohiuddinpur in the working area of ​​partapur 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long 3 lt ab cable 3x95+1x70+1x16 4 lt ab cable 3x50+1x35+1x16 5 3 phase lt distribution box 6 acsr weasal conductor 7 63 kva t / f 8 line material such as stay set, piercing clamp, dead clamp, earthing rod, disc insulator, stone pad, pin insulator, x arm, ms angle, ms channel, gi wire etc. 9 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 10 pcc pole 8.5 mtr long 11 lt ab cable 3x95+1x70+1x16 12 lt ab cable 3x50+1x35+1x16 13 3 phase lt distribution box 14 acsr weasal conductor 15 63 kva t / f 16 line material such as stay set, piercing clamp, dead clamp, earthing rod, disc insulator, stone pad, pin insulator, x arm, ms angle, ms channel, gi wire etc. 17 erection of pcc pole 8.5 mtr after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 18 erection of double pole on pcc pole 8.5 mtr after digging a pit of size1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 19 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 20 grouting of pcc pole 8.5 mtr 21 fixing of lt accessories 22 providing and fixing of suspension clamp & j hook 23 laying, stringing & proper sagging of acsr weasal conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 24 earthing of each 11 kv lineproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 25 providing and fixing of clamp with nut & bolt 26 laying, lifting of lt ab cable of size 3x95+1x70+1x16 27 laying, lifting of lt ab cable of size3x50+1x35+1x16 28 fixing of distribution box 29 installation and errection of 63 kva t / f on double pole...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37119010 construction of damaged plinth, fencing and double pole of 250 kva transformer installed on poshit kunda road from 33 / 11 kv sub station partapur in the working area of ​​sub division i baghpat road under power distribution division i, meerut, work system improvement scheme ( under business plan year 2023 24 ) . 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 stp pole 11 mtr. long 3 acsr weasal conductor 4 line material such as pin insulator, disc insulator, earthing rod, stay set, stone pad, fuse set, tpmo etc. 5 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 6 stp pole 11 mtr. long 7 acsr weasal conductor 8 line material such as pin insulator, disc insulator, earthing rod, stay set, stone pad, fuse set, tpmo etc. 9 erection of stp pole 11 mtr. long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 10 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 11 grouting of stp pole 11 mtr. long 12 fixing of lt accessories 13 laying, stringing & proper sagging of acsr weasal conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 14 earthing of each 11 kv lineproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 15 providing and fixing of clamp with nut & bolt 16 providing and fixing of ms nut and bolts 17 fencing of 250 kva t / f 18 water level earthing 250 kva t / f 19 making of plinth 250 kva t / f of size 6x6x3 ( feet ) 20 providing and fixing of 11 kv fuse set 21 providing and fixing of 11 kv tpmo 22 providing and fixing of tailless unit...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37118170 tender for power distribution division i, subdivision ii under meerut. system improvement plan ( business plan year 2023 24 ) on the work of connecting 33 / 11 kv power sub station gagol ii due to overloading of 11 kv nutritious cattle feed fed from 33 / 11 kv sub station gagol i in the work area of ​​partapur. under | 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 st pole 11 mtr long 3 xlpe cable 3x185 sq.mm 4 11 kv cable box 3x185 sq.mm 5 11 kv vcb outgoing 200x / 100 / 5 6 line material such as stay set, stay wire, ms channel, ms angle etc. 7 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 8 st pole 11 mtr long 9 xlpe cable 3x185 sq.mm 10 11 kv cable box 3x185 sq.mm 11 11 kv vcb outgoing 200 / 100 / 5 12 line material such as stay set, stay wire, ms channel, ms angle etc. 13 erection of st pole 11 mtr after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 14 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 15 fixing of lt accessories 16 laying of 11 kv xlpe cable including cost of sand and bricks 17 earthing of each 11 kv lineproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 18 filling of 11 kv cable box 3x185 sq.mm 19 installation of vcb outgoing 200 / 100 / 5...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37099319 tender for sub divisional officer ii under electricity distribution division i, meerut. work under business plan year 2023 24 at various places in shatabdi nagar sector 5 and udyogpuram in partapurs working area. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long 3 lt ab cable 3x120+1x70+1x16 4 lt ab cable 3x50+1x35+1x16 5 3 phase lt distribution box 6 line material such as stay set, piercing clamp, dead clamp, earthing rod etc. 7 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 8 pcc pole 8.5 mtr long 9 lt ab cable 3x120+1x70+1x16 10 lt ab cable 3x50+1x35+1x16 11 3 phase lt distribution box 12 line material such as stay set, piercing clamp, dead clamp, earthing rod etc. 13 erection of pcc pole 8.5 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 14 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 15 grouting of pcc 16 fixing of lt accessories 17 providing and fixing of suspension clamp & j hook 18 removing of old acsr weasal conductor 19 earthing of each 11 kv lineproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 20 lt ab cable 3x120+1x70+1x16 21 lt ab cable 3x50+1x35+1x16 22 fixing of distribution box 23 back cartage old and damage acsr weasal conductor...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37099088 work under the business plan year 2023 24 at various places at gagol first sub centre in the work area of ​​sub divisional officer ii paratapur under electricity distribution division i, meerut. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / st pole 11 mtr long 3 lt ab cable 3x120+1x70+1x16 4 lt ab cable 3x95+1x70+1x16 5 lt ab cable 3x50+1x35+1x16 6 63 / 100 kva t / f 7 3 phase lt distribution box 8 acsr weasal / dog conductor 9 11 kv vcb o / g ctr 200 / 100 / 5 a, 35 mva 10 3x185 sq.mm xlpe cable 11 line material as such earthing rod, stay set, stone pad, ms angle, ms channel, piercing clamp, dead clamp, pin insulator, disc insulator, j hook etc, 12 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 13 pcc pole 8.5 mtr long / st pole 11 mtr long 14 lt ab cable 3x120+1x70+1x16 15 lt ab cable 3x95+1x70+1x16 16 lt ab cable 3x50+1x35+1x16 17 63 / 100 kva t / f 18 3 phase lt distribution box 19 acsr weasal / dog conductor 20 11 kv vcb o / g ctr 200 / 100 / 5 a, 35 mva 21 3x185 sq.mm xlpe cable 22 line material as such earthing rod, stay set, stone pad, ms angle, ms channel, piercing clamp, dead clamp, pin insulator, disc insulator, j hook etc, 23 erection of pcc pole 8.5 mtr / st pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 24 erection of double pole on pcc pole 8.5 / st pole 11 mtr long after digging a pit of size1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 25 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 26 fixing of lt accessories 27 mounting of 63 / 100 kva t / f with proper jumpering of ht side and fixing of cable on lt side of t / f. 28 providing and fixing of suspension clamp, holding clamp & lt clamp 29 removing of old acsr weasal 30 laying, stringing & proper sagging of acsr weasal / dog conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 31 earthing of each 11 kv line and t / fproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 32 grouting of pcc / st pole 33 providing and fixing of ms nut & bolts off size 34 providing and fixing of 11 kv fuse set 35 lt ab cable 3x120+1x70+1x16 36 lt ab cable 3x95+1x70+1x16 37 lt ab cable 3x50+1x35+1x16 38 installation of vcb for o / g ctr 200 / 100 / 5a, 35 mva 39 laying of xlpe cable 3x185 sq.mm 40 providing and fixing of jointing kit 3x185 sq.mm xlpe cable outdoor 41 providing and fixing of jointing kit 3x185 sq.mm xlpe cable indoor 42 back cartage old and damage acsr weasal conductor 43 back cartage st pole old and used...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37099047 sub divisional officer ii under electricity distribution division i, meerut. 33 / 11 kv power substation partapur in working area of ​​partapur. work under business plan year 2023 24 at various places in shatabdinagar sector 5 and udyogpuram. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / stp pole 11 mtr. long 3 lt ab cable 3x120+1x95+1x16 4 lt ab cable 3x95+1x70+1x16 5 lt ab cable 3x50+1x35+1x16 6 3 phase lt distribution box 7 acsr rabbit conductor 8 line material such as stay set, piercing clamp, dead clamp, earthing rod, pin insulator, x arms etc. 9 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 10 pcc pole 8.5 mtr long / stp pole 11 mtr. long 11 lt ab cable 3x120+1x95+1x16 12 lt ab cable 3x95+1x70+1x16 13 lt ab cable 3x50+1x35+1x16 14 3 phase lt distribution box 15 acsr rabbit conductor 16 line material such as stay set, piercing clamp, dead clamp, earthing rod, pin insulator, x arms etc. 17 erection of pcc pole 8.5 mtr / stp pole 11 mtr. long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 18 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 19 fixing of lt accessories 20 providing and fixing of suspension clamp & j hook 21 removing of old acsr weasal conductor 22 laying, stringing & proper sagging of acsr rabbit conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 23 earthing of each 11 kv lineproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 24 providing and fixing of clamp with nut & bolt 25 laying, lifting of lt ab cable of size 3x120+1x95+1x16 26 laying, lifting of lt ab cable of size 3x95+1x70+1x16 27 laying, lifting of lt ab cable of size3x50+1x35+1x16 28 fixing of distribution box 29 back cartage old and damage acsr weasal conductor...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37099002 mohiuddinpur in the working area of ​​sub divisional officer i and ii, baghpat road / partapur under electricity distribution division i meerut. work under business plan year 2023 24 at various places in dungrawali and gagol pratham. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / st pole 11 mtr long 3 lt ab cable 3x120+1x70+1x16 4 lt ab cable 3x95+1x70+1x16 5 3 phase lt distribution box 6 acsr weasal / dog conductor 7 line material as such stay set, earthing rod, dead clamp, piercing clamp, lt shackle insulator etc. 8 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 9 pcc pole 8.5 mtr long / st pole 11 mtr long 10 lt ab cable 3x120+1x70+1x16 11 lt ab cable 3x95+1x70+1x16 12 3 phase lt distribution box 13 acsr weasal / dog conductor 14 line material as such stay set, earthing rod, dead clamp, piercing clamp, lt shackle insulator etc. 15 erection of pcc pole 8.5 mtr / st pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 16 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 17 fixing of lt accessories 18 providing and fixing of suspension clamp, holding clamp & lt clamp 19 removing of old acsr weasal conductor 20 laying, stringing & proper sagging of acsr weasal conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 21 earthing of each 11 kv line and t / fproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 22 lt ab cable 3x120+1x70+1x16 23 lt ab cable 3x95+1x70+1x16 24 back cartage old and damage acsr weasal conductor site to centre store 25 back cartage gi wire site to centre store...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37098793 tender for sub divisional officer ii under electricity distribution division i, meerut. work under business plan year 2023 24 at various places in partapurs work area, gagol first and shatabdi nagar sector 5 and sector 4. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / stp pole 11 mtr. long 3 lt ab cable 3x95+1x70+1x16 4 lt ab cable 3x50+1x35+1x16 5 3 phase lt distribution box 6 acsr weasal conductor 7 line material such as stay set, piercing clamp, dead clamp, earthing rod, pin insulator, x arm etc. 8 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 9 pcc pole 8.5 mtr long / stp pole 11 mtr. long 10 lt ab cable 3x95+1x70+1x16 11 lt ab cable 3x50+1x35+1x16 12 3 phase lt distribution box 13 acsr weasal conductor 14 line material such as stay set, piercing clamp, dead clamp, earthing rod, pin insulator, x arm etc. 15 erection of pcc pole 8.5 mtr / stp pole 11 mtr. long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 16 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 17 grouting of pcc / st pole 18 fixing of lt accessories 19 providing and fixing of suspension clamp & j hook 20 removing of old acsr weasal conductor 21 laying, stringing & proper sagging of acsr weasal conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 22 earthing of each 11 kv lineproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 23 providing and fixing of clamp with nut & bolt 24 laying, lifting of lt ab cable of size 3x95+1x70+1x16 25 laying, lifting of lt ab cable of size3x50+1x35+1x16 26 fixing of distribution box 27 back cartage old and damage acsr weasal conductor...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37097793 work under business plan year 2023 24 at various places in gagol i and udyogpuram ii in the working area of ​​sub divisional officer ii paratapur under electricity distribution division i, meerut. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / stp pole 11 mtr. long 3 acsr weasal conductor 4 acsr rabbit conductor 5 line material such as stay set, earthing rod, disc insulator, pin insulator, x arm etc. 6 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 7 pcc pole 8.5 mtr long / stp pole 11 mtr. long 8 acsr weasal conductor 9 acsr rabbit conductor 10 line material such as stay set, earthing rod, disc insulator, pin insulator, x arm etc. 11 erection of pcc pole 8.5 mtr / stp pole 11 mtr. long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 12 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 13 grouting of pcc / stp pole 14 fixing of lt accessories 15 removing of old acsr weasal conductor 16 laying, stringing & proper sagging of acsr weasal / rabbit conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 17 earthing of each 11 kv lineproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 18 providing and fixing of clamp with nut & bolt 19 fencing of 250 kva t / f 20 water level earthing 250 kva t / f 21 making of plinth 250 kva t / f of size 6x6x3 ( feet ) 22 providing and fixing of 11 kv fuse set 23 providing and fixing of 11 kv tpmo 24 providing and fixing of tailless unit 25 back cartage old and damage acsr weasal conductor...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37097713 sub divisional officer ii under electricity distribution division i, meerut. work under business plan year 2023 24 at various places in partapurs working area, gogol first and shatabdi nagar sector 5. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / stp pole 11 mtr. long 3 lt ab cable 3x120+1x70+1x16 4 lt ab cable 3x95+1x70+1x16 5 lt ab cable 3x50+1x35+1x16 6 3 phase lt distribution box 7 acsr weasal conductor 8 line material such as stay set, piercing clamp, dead clamp, earthing rod, pin insulator, x arm etc. 9 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 10 pcc pole 8.5 mtr long / stp pole 11 mtr. long 11 lt ab cable 3x120+1x70+1x16 12 lt ab cable 3x95+1x70+1x16 13 lt ab cable 3x50+1x35+1x16 14 3 phase lt distribution box 15 acsr weasal conductor 16 line material such as stay set, piercing clamp, dead clamp, earthing rod, pin insulator, x arm etc. 17 erection of pcc pole 8.5 mtr / stp pole 11 mtr. long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 18 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 19 grouting of pcc / stp pole 20 fixing of lt accessories 21 providing and fixing of suspension clamp & j hook 22 removing of old acsr weasal conductor 23 laying, stringing & proper sagging of acsr weasal conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 24 earthing of each 11 kv lineproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 25 providing and fixing of clamp with nut & bolt 26 laying, lifting of lt ab cable of size 3x120+1x70+1x16 27 laying, lifting of lt ab cable of size 3x95+1x70+1x16 28 laying, lifting of lt ab cable of size3x50+1x35+1x16 29 fixing of distribution box 30 back cartage old and damage acsr weasal conductor...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

37085718 tender for sub divisional officer ii under electricity distribution division i meerut. gogol in the work area of ​​partapur i udyogpuram ii. work under business plan year 2023 24 at various places in partapur and shatabdinagar sector 5. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / st pole 11 mtr long 3 lt ab cable 3x120+1x70+1x16 4 lt ab cable 3x95+1x70+1x16 5 lt ab cable 3x50+1x35+1x16 6 63 kva t / f 7 3 phase lt distribution box 8 acsr weasal / dog conductor 9 line material as such stay set, pin insulator, disc insulator, earthing rod, gi wire, ms angle, ms channel, top channel, dropper channel, dead clamp, piercing clamp, f bracket, shackle insulator, stone pad etc. 10 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 11 pcc pole 8.5 mtr long / st pole 11 mtr long 12 lt ab cable 3x120+1x70+1x16 13 lt ab cable 3x95+1x70+1x16 14 lt ab cable 3x50+1x35+1x16 15 63 kva t / f 16 3 phase lt distribution box 17 acsr weasal / dog conductor 18 line material as such stay set, pin insulator, disc insulator, earthing rod, gi wire, ms angle, ms channel, top channel, dropper channel, dead clamp, piercing clamp, f bracket, shackle insulator, stone pad etc. 19 erection of pcc pole 8.5 mtr / st pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 20 erection of double pole on pcc pole 8.5 / st pole 11 mtr long after digging a pit of size1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 21 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 22 fixing of lt accessories 23 mounting of 63 kva t / f with proper jumpering of ht side and fixing of cable on lt side of t / f. 24 providing and fixing of suspension clamp, holding clamp & lt clamp 25 removing of old acsr weasal 26 laying, stringing & proper sagging of acsr weasal conductor for 3 phase, 4 wire lt line including binding & jumpering properly. 27 earthing of each 11 kv line and t / fproperly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 28 grouting of pcc / st pole 29 providing and fixing of ms nut & bolts off size 30 lt ab cable 3x120+1x70+1x16 31 lt ab cable 3x95+1x70+1x16 32 lt ab cable 3x50+1x35+1x16 33 back cartage old and damage acsr weasal conductor 34 back cartage st pole old and used...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36873372 full deposit scheme under electricity distribution division i, meerut, by md. gyas s / o wali mohammad, resident 178, maliana, baghpat road, meerut, radhakunj phase 2 khasra no. 40 m. release of 80 kva load for external electrification and shifting of 11 kv line going over the plot of mr. kamal kumar s / o mr. rohitash kumar, resident of village rampur pawti, meerut. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends : 2 pcc pole 8.5 mtr. long / st pole 11 mtr. long 3 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set, ab cable etc. 4 100 kva t / f including complete related material required for transformer by crane 5 cartage of following material from je, store to site of work including loading & unloading at both ends : 6 pcc pole 8.5 mtr. long / st pole 11 mtr. long 7 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set, ab cable etc. 8 100kva t / f including complete related material required for transformer by crane 9 erection of pcc pole 8.5 mtr. long / stp pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 10 fabrication and fixing of all 11 kv ht / lt line 11 erection of double pole on pcc / stpafter digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 12 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set, 11 kv pin insulators as per double pole 13 mounting of 100kva t / f by crane with proper jumpring of ht side and fixing of cable on lt side 14 making a section pole to exist pole jumpring of ht side and all 11 kv accessories 15 erection of stay rod complete after digging a pit of size 1.20 x0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 16 laying lifting stringing of proper sagging of acsr weasal / rabbit conductor for 3 phase, 3 wire 33 kv line including binding & jumpering properly. 17 laying, lifting & sagging of lt line abc cable of size 18 95x3+1x70+1x16 mm 19 earthing of each 11 kv line & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 20 grouting of pcc / stp pole as per respo 21 fixing of lt distribution box on support and making the proper connection 22 cutting & chopping tree branches near side of line for making the clearance between line and tree 23 providing and fixing stay clamps 24 providing and fixing holding clamps, prc / j hook 25 providing and fixing lt clamps 26 providing stay insulator 27 providing and fixing fuse set 28 providing and fixing prc lead 29 providing and fixing bolts and nuts...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36872963 tender for shri kamal kumar s / o rohtash kumar r / o 39. bhagirathi delhi road, meerut in full deposit scheme under electricity distribution division i, meerut, in village rampur pvt. khasra no. 303. external electrification of unauthorized residential colony constructed in laxmi enclave, meerut for releasing 284 kva load. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends : 2 pcc pole 8.5 mtr. long / st pole 11 mtr. long 3 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set, ab cable etc. 4 100 / 250 kva t / f including complete related material required for transformer by crane 5 cartage of following material from je, store to site of work including loading & unloading at both ends : 6 pcc pole 8.5 mtr. long / st pole 11 mtr. long 7 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set, ab cable etc. 8 250 kva t / f including complete related material required for transformer by crane 9 erection of pcc pole 8.5 mtr. long / stp pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 10 fabrication and fixing of all 11 kv ht / lt line 11 erection of double pole on pcc / stpafter digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 12 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set, 11 kv pin insulators as per double pole 13 mounting of 100 / 250 kva t / f by crane with proper jumpring of ht side and fixing of cable on lt side 14 making a section pole to exist pole jumpring of ht side and all 11 kv accessories 15 erection of stay rod complete after digging a pit of size 1.20 x0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 16 laying lifting stringing of proper sagging of acsr weasal / rabbit conductor for 3 phase, 3 wire 33 kv line including binding & jumpering properly. 17 laying, lifting & sagging of lt line abc cable of size 18 95x3+1x70+1x16 mm 19 laying, lifting of lt line lt xlpe cable of size 3.5x240 mm 20 earthing of each 11 kv line & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 21 grouting of pcc / stp pole as per respo 22 fixing of lt distribution box on support and making the proper connection 23 cutting & chopping tree branches near side of line for making the clearance between line and tree 24 providing and fixing stay clamps 25 providing and fixing holding clamps, prc / j hook 26 providing and fixing lt clamps 27 providing stay insulator 28 providing and fixing bolts and nuts 29 construction of plinth of 250 kva t / f 30 wiremesh security fencing for 250 kva t / f 31 earthing of 250 kva t / f upto level of water level 32 providing and fixing of tail less unit 33 providing and fixing fuse set 34 providing and fixing tpmo set 35 providing and fixing prc lead 36 providing and fixing of aluminium lugs 400 sq.mm...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36846037 work of releasing 477 kva load for external electrification of village baral, meerut. unauthorized residential colony balaji dham khasra no. 417 / 1, 2, 3, 4, 5 and khasra no. 502 / 1, 2 by mr. praveen kumar s / o mr. sukhveer singh in full deposit scheme under electricity distribution division i, meerut , 3 1 cartage of following material from store center meerut to je store including loading & unloading at both ends : 2 pcc pole 8.5 mtr. long / st pole 11 mtr. long 3 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set, ab cable etc. 4 100 / 250 kva t / f including complete related material required for transformer by crane 5 cartage of following material from je, store to site of work including loading & unloading at both ends : 6 pcc pole 8.5 mtr. long / st pole 11 mtr. long 7 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set, ab cable etc. 8 250 kva t / f including complete related material required for transformer by crane 9 erection of pcc pole 8.5 mtr. long / stp pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 10 fabrication and fixing of all 11 kv ht / lt line 11 erection of double pole on pcc / stpafter digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 12 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set, 11 kv pin insulators as per double pole 13 mounting of 100 / 250 kva t / f by crane with proper jumpring of ht side and fixing of cable on lt side 14 making a section pole to exist pole jumpring of ht side and all 11 kv accessories 15 erection of stay rod complete after digging a pit of size 1.20 x0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 16 laying lifting stringing of proper sagging of acsr weasal / rabbit conductor for 3 phase, 3 wire 33 kv line including binding & jumpering properly. 17 11 kv ht line in making 3x70 sq.mm xlpe cable 18 laying, lifting & sagging of lt line abc cable of size 19 95x3+1x70+1x16 mm 20 laying, lifting of lt line lt xlpe cable of size 3.5x240 mm 21 earthing of each 11 kv line & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 22 grouting of pcc / stp pole as per respo 23 fixing of lt distribution box on support and making the proper connection 24 cutting & chopping tree branches near side of line for making the clearance between line and tree 25 providing and fixing stay clamps 26 providing and fixing holding clamps, prc / j hook 27 providing and fixing lt clamps 28 providing stay insulator 29 providing and fixing bolts and nuts 30 construction of plinth of 250 kva t / f 31 wiremesh security fencing for 250 kva t / f 32 earthing of 250 kva t / f upto level of water level 33 providing and fixing of tail less unit 34 providing and fixing 11 kv jointing kit 3x70 sq.mm 35 providing and fixing fuse set 36 providing and fixing tpmo set 37 providing and fixing prc lead 38 providing and fixing of aluminium lugs 400 sq.mm...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36846021 work of release of 202 kva load for external electrification of khasra no. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends : 2 pcc pole 8.5 mtr. long / st pole 11 mtr. long 3 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set, ab cable etc. 4 250 kva t / f including complete related material required for transformer by crane 5 cartage of following material from je, store to site of work including loading & unloading at both ends : 6 pcc pole 8.5 mtr. long / st pole 11 mtr. long 7 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set, ab cable etc. 8 250 kva t / f including complete related material required for transformer by crane 9 erection of pcc pole 8.5 mtr. long / stp pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 10 fabrication and fixing of all 11 kv ht / lt line 11 erection of double pole on pcc / stpafter digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 12 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set, 11 kv pin insulators as per double pole 13 mounting of 250 kva t / f by crane with proper jumpring of ht side and fixing of cable on lt side 14 making a section pole to exist pole jumpring of ht side and all 11 kv accessories 15 erection of stay rod complete after digging a pit of size 1.20 x0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 16 laying lifting stringing of proper sagging of acsr weasal / rabbit conductor for 3 phase, 3 wire 33 kv line including binding & jumpering properly. 17 laying, lifting & sagging of lt line abc cable of size 18 95x3+1x70+1x16 mm 19 laying, lifting of lt line lt xlpe cable of size 3.5x240 mm 20 earthing of each 11 kv line & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 21 grouting of pcc / stp pole as per respo 22 fixing of lt distribution box on support and making the proper connection 23 cutting & chopping tree branches near side of line for making the clearance between line and tree 24 providing and fixing stay clamps 25 providing and fixing holding clamps, prc / j hook 26 providing and fixing lt clamps 27 providing stay insulator 28 providing and fixing bolts and nuts 29 construction of plinth of 250 kva t / f 30 wiremesh security fencing for 250 kva t / f 31 earthing of 250 kva t / f upto level of water level 32 providing and fixing fuse set 33 providing and fixing tpmo set 34 providing and fixing prc lead 35 providing and fixing of tail less unit 36 providing and fixing of aluminium lugs 400 sq.mm...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

36090875 under electricity distribution division khurja, the work related to issue of connection as per the application on nivesh mitra / jhatpat portal in full deposit scheme item. carriage of fallowings from esc. bsr to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 kms. 3 s.t pole 13 mtr. long 4 s.t pole 11 mtr. long 5 pcc pole 8.5 mtr long. 6 carriage of all line material from store center bsr to j.e store sub station as acsr weasel conductor, abc conductor gi wire, earth wire. m.s. chanel, angle, stay & earthig rods, barbed wire. disc insulator etc. 7 erection ofsingle pole support including complete 1 it fittings as per respo manual and as per direction of engineer in charge including the cost of labour, t&p and carrier etc. required for proper completion of work. 8 erection of double pole / scation pole support including complete 1 it fittings as per respo manual and as per direction of engineer in charge including the cost of labour, t&p and carrier etc. required for proper completion of work. 9 grouting of single support shall be grouted with cement, sand and birck ballast / stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast / stone ballast, etc. as per actual size requirement, as per respo manual and as per direction of engineer in charge including the cost of labour, t&p and carrier etc. required for proper completion of work. 10 grouting of double pole support shall be grouted with cement, sand and birck ballast / stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast / stone ballast, etc. as per actual size requirement, as per respo manual and as per direction of engineer in charge including the cost of labour, t&p and carrier etc. required for proper completion of work. 11 carriage of all line material from j.e store sub station to pit site acsr weasel conductor, abc conductor gi wire, earth wire. m.s. chanel, angle, stay & earthig rods, barbed wire. disc insulator etc. 12 cutting / drilling / welding of ms angle iron for making guarding angle size 65x65x6 / 50x50x6 mm including the work of fixing the bracket on pcc / st pole for construction of the line. 13 carriage of 11 kv ct / pt metering polemounted unit varius ratio 14 carriage and installation of 11 kv pilferresistant metering cubicle with out cable termination kit 15 mounting of 11 kv ct / pt unit varius ratio 16 making / filling of 11 kv cable jointing kit varius sizexlpe cable 17 loading / unloading & carriage of t / ffrom esc. bsr to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 kms. 18 25 kva t / f 19 63 kva t / f 20 fixing of 11 kv stay rod with stay wire in proper way with nozelling 21 grouting of 11 kv stay rods 22 guarding of 11 k v line at road crossing by laying 3 nos. gl wire of size 6 / 10 swg parallel and fixing of lacings ( tilli ) at a distance at 1.5 mlrs as per direction of supervising engineer / respo mannual it. includes the cost of labour, t&p carrier etc. required lor proper completing of work 23 laying, sagging. stringing and binding and jumpering of 11 kv xlpe cable 3*70 square mm & outher size newly erected pole as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t&p, carrier etc. requried for proper completion of work. 24 laying, sagging. stringing and binding and jumpering of acsr weisal , rabbit, dog newly erected pole as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t&p, carrier etc. requried for proper completion of work. 25 acsr weisal conductor 26 acsr rabbit / dog conductor 27 abc cable 3*50 square mm 28 abc cable 3*95 square mm 29 abc cable 3*120 square mm 30 fixing of earthing rod 31 fixing of pin insulator 32 fixing of side bracket 33 fixing disc insulator 34 fixing ofv type x rm / toff channel 35 fixing of sub station angle. 36 mounting & installation of t / f from d / p 37 25 kva t / f 38 63 kva t / f 39 the folloing material is required to be supplied by the contractor. 40 holding clamp. 41 11kv cable jointing kit 3*70 square mm xlpe cable 42 double pole clamp 43 side bracket 44 f clamp 45 lt clamp 46 pg clamp 47 j hook 48 earth clamp 49 stay clamp 50 dead & clamps 51 stay insulator for 11 kv 52 suspension clamps 53 lt insulator 54 bolt & nut off size....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

35366267 running tender for regarding new connection on jhatpat portal full deposit work scheme and sansad nidhi / vidhayak nidhi deposit work in the area of edsd i, daurala / edsd ii sardhana town / edsd iii sardhana dehat, under edd ii, meerut 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. :– 2 a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 3 cartage of line material from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 20 km. ( 15 qtl. ) 4 cartage of 10 kva / 25 kva / 63 kva / 100 kva transformer from store centre to site of work including loading & unloading at both site 5 cartage of following material from je store to site of work including loading & unloading at both ends maximum distance up to 40 km. :– a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 6 safe cartage of ct / pt of diffrent ratio from store centre meerut to site of work including loading and unloading at both ends. 7 dissmentling of damaged & broken p.c.c. / s.t.pole / r.s. joist by digging the pits & removel of complete h.t. / l.t. line accessories . 8 earting of each 11 kv line pople & t / f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 9 erection ofpcc pole 8.5 mtr long / stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 10 fabrication and fixing of all 11 kv h.t / l.t. line accessories. 11 erection of double pole on pcc pole 8.5 mtr after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators and making connection properly. 12 fabrication and fixing of top channel, dropper channel transformer base angle fuse set, tpmo etc. 13 mounting of 10 kva / 25 kva / 63 kva / 100 kva with proper jumping of ht side and fixing of cable on lt. side of t / f making connection properly. 14 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 15 erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 16 laying lifting stringing of proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 17 laying lifting stringing of proper sagging of abc bunch conductor. 18 laying lifting & sagging of lt line with a.c.s.r. weaseal / rabbit conductor including proper binding & jumpring: a ) 3 phase 4 wire line. 19 b ) 2 phase 3 wire line. 20 c ) 1 phase 2 wire line 21 guarding of line with g.i. wire having 2 nohorizontal wire& 3 mtr distance odf laces of tenswg g.i wire after fabrication of guard cross arms of& fixing the same in supports. 22 grouting of pcc / st poles with dust, cement & stone blast concreting. 23 cutting & chopping tree branches near side of line for making the clearance between line and tree. 24 fixing of lt distribution box along with providing clamp nut & bolts 25 providing and fixing stay clamps . 26 providing and fixing holding clamps . 27 providing and fixing f clamps . 28 providing and fixing lt clamps . 29 providing and fixing ltinsulator. 30 providing and fixing bolt and nuts . 31 suspension clamp with j hook 32 dead & clamp with j hook 33 installation of ct / pt & making connection properly 34 fixing of 11 kv heat shrinkable cable jointing kits...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

35196659 releasing of new connection and construction of ht / lt line applied in jhatpat / nivesh mitra portal consumer ( running contract under deposit scheme ) in the area of edsd i, baghpat road under jurisdiction of edd i, meerut 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / stp pole 11 mtr. long. 3 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 4 25 kva to 100 kva t / f including complete related material required for transformer. 5 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 6 pcc pole 8.5 mtr long / stp pole 11 mtr. long. 7 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 8 25 kva to 100 kva t / f including complete related material required for transformer. 9 erection of pcc pole 8.5 mtr long / stp pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 10 fabrication and fixing of all 11 kv ht / lt line accessories. 11 erection of double pole on pcc pole 8.5 mtr after digging a pit of size1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 12 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators on d / p pole. 13 mounting of 25 to 100 kva t / f with proper jumpering of ht side and fixing of cable on lt side of t / f. 14 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 15 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 16 laying lifting stringing & proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 17 laying of lt abc cable of various size including fixing of all lt abc accessories on support 18 fixing of distribution box including fixing the cable from transformar and consumer service cable 19 earthing of each 11 kv line pole & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 20 guarding of line with g.i. wire having 2 no. horizontal wire & 3 mtr distance of swg g.i. wire after fabrication of guard cross arms of & fixing the same in supports. 21 cutting & chopping tree branches near side of line for making the clearance between line and tree....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

34941787 releasing of new connection and construction of ht / lt line applied in jhatpat / nivesh mitra portal consumer ( running contract under deposit scheme ) in the area of edsd i, baghpat road under jurisdiction of edd i, meerut 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / stp pole 11 mtr. long. 3 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 4 25 kva to 100 kva t / f including complete related material required for transformer. 5 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 6 pcc pole 8.5 mtr long / stp pole 11 mtr. long. 7 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 8 25 kva to 100 kva t / f including complete related material required for transformer. 9 erection of pcc pole 8.5 mtr long / stp pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 10 fabrication and fixing of all 11 kv ht / lt line accessories. 11 erection of double pole on pcc pole 8.5 mtr after digging a pit of size1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 12 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators on d / p pole. 13 mounting of 25 to 100 kva t / f with proper jumpering of ht side and fixing of cable on lt side of t / f. 14 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 15 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 16 laying lifting stringing & proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 17 laying of lt abc cable of various size including fixing of all lt abc accessories on support 18 fixing of distribution box including fixing the cable from transformar and consumer service cable 19 earthing of each 11 kv line pole & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 20 guarding of line with g.i. wire having 2 no. horizontal wire & 3 mtr distance of swg g.i. wire after fabrication of guard cross arms of & fixing the same in supports. 21 cutting & chopping tree branches near side of line for making the clearance between line and tree....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

34272969 releasing of new connection and construction of ht / lt line applied in jhatpat / nivesh mitra portal consumer ( running contract under deposit scheme ) in the area of edsd iii, meerut under jurisdiction of edd i, meerut 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. : 2 pcc pole 8.5 mtr long / stp pole 11 mtr. long. 3 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 4 25 kva to 100 kva t / f including complete related material required for transformer. 5 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 30 km. : 6 pcc pole 8.5 mtr long / stp pole 11 mtr. long. 7 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 8 25 kva to 100 kva t / f including complete related material required for transformer. 9 erection of pcc pole 8.5 mtr long / stp pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 10 fabrication and fixing of all 11 kv ht / lt line accessories. 11 erection of double pole on pcc pole 8.5 mtr after digging a pit of size1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 12 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators on d / p pole. 13 mounting of 25 to 100 kva t / f with proper jumpering of ht side and fixing of cable on lt side of t / f. 14 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 15 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 16 laying lifting stringing & proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 17 laying of lt abc cable of various size including fixing of all lt abc accessories on support 18 fixing of distribution box including fixing the cable from transformar and consumer service cable 19 earthing of each 11 kv line pole & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 20 guarding of line with g.i. wire having 2 no. horizontal wire & 3 mtr distance of swg g.i. wire after fabrication of guard cross arms of & fixing the same in supports. 21 cutting & chopping tree branches near side of line for making the clearance between line and tree....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

33875059 regarding running tender for new connection on jhatpat portal full deposit work scheme and sansad nidhi / vidhayak nidhi deposit work in the area of edsd i, daurala under edd ii, meerut, under edc 2 meerut. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. :– 2 a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 3 cartage of line material from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 20 km. ( 15 qtl. ) 4 cartage of 10 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site 5 cartage of following material from je store to site of work including loading & unloading at both ends maximum distance up to 40 km. :– a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 6 dissmentling of damaged & broken p.c.c. / s.t.pole / r.s. joist by digging the pits & removel of complete h.t. / l.t. line accessories . 7 eartingh of each 11 kv line pople & t / f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 8 erection ofpcc pole 8.5 mtr long / stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 9 fabrication and fixing of all 11 kv h.t / l.t. line accessories. 10 erection of double pole on pcc pole 8.5 mtr after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators and making connection properly. 11 mounting of 10 to 100 kva t / f with proper jumping of ht side and fixing of cable on lt. side of t / f making connection properly. 12 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 13 erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 14 laying lifting stringing of proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 15 laying lifting stringing of proper sagging of acsr rabbit conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 16 laying lifting & sagging of lt line with a.b.c bunch conductor including proper binding & jumpring: a ) 3 phase 4 wire line. 17 grouting of pcc / st poles with dust, cement & stone blast concreting. 18 cutting & chopping tree branches near side of line for making the clearance between line and tree ( near about 100 branches ) . 19 fixing of lt distribution box along with providing clamp nut & bolts 20 providing and fixing stay clamps . 21 providing and fixing f clamp 22 providing and fixing holding clamp 23 providing and fixing lt clamps . 24 providing and fixing ltinsulator clamps . 25 providing and fixing bolt and nuts ....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

33653669 regarding construction of new, old line and issued of new connection under deposit work at various 33 / 11 kv sub stations under edsd i, maliyana under edd iii, meerut 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. : 2 pcc pole 8.5 mtr long / st pole 11 mtr. long. 3 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 4 25 kv to 100 kv t / f including complete related material required for transformer. 5 xlpe 11 kv cable 3x70 to 185 mm 6 ct pt unit complete 7 meter cubical 8 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 40 km. : 9 pcc pole 8.5 mtr long / st pole 11 mtr. long. 10 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 11 25 kv to 100 kv t / f including complete related material required for transformer. 12 xlpe 11 kv cable 3x70 to 185 mm. 13 ct pt unit complete 14 meter cubical 15 erection of pcc pole 8.5 mtr long / stp pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 16 fabrication and fixing of all 11 kv ht / lt line accessories. 17 erection of double pole on pcc pole 8.5 mtr after digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 18 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators. 19 mounting of 25 to 100 kva t / f with proper jumping of ht side and fixing of cable on lt side of t / f. 20 erection of stay rod complete after digging a pit of size 1.20 x0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 21 laying lifting stringing of proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 22 laying lifting & sagging of lt line with acsr weasel conductor including proper binding & jumpring. 23 dismantel of ct / pt unit 24 dismantel of meeter cubical 25 earthingh of each 11 kv line pople & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 26 guarding of line with g.i. wire having 2 no. horizontal wire & 3 mtr distance odf laces of ten swg g.i. wire after fabrication of guard cross arms of & fixing the same in supports. 27 providing and fixing stay clamps. 28 providing and fixing holding clamps. 29 providing and fixing lt clamps. 30 providing and fixing lt insulator clamps. 31 providing and fixing bolt and nuts. 32 providing and fixing of g.i. pipe 33 providing and fixing of prc clamp 34 providing and fixing of j hook 35 providing and fixing of dead end clamp with suspension clamp 36 laying of 11 kv xlpe cable in cable tranch after digging of tranch. then filling the cable tranch with excavated earth soil bricks over the cable. 37 fixing the cable jointing kit with the end of xlpe cable including mounting the same on pole with proper binding. 38 fixing of distributon box on suport after providing and fixing of fixing clamp including connection of lt abc cable 39 fixing of meter cubical including grouting the bolt and nut and connection of cable 40 laying lifting and sagging including mounting of lt abc cable of size 1x25 to 3x95 including fixing of all required its accessorise 41 water level earthing with gi pipe 32 mm dia and ms flat of size 45x5mm...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32836609 regarding erection of pole in long span, guarding of line and fixing pvc sheer on steel pole and strengthening of 11 kv lt line at kawar marg in under the area of edd ii mawana under edc 2 meerut. 1 cartage of following from store center meerut to je store including loading& unloading at both ends maximum distance up to 40 km. 2 a ) pcc pole 8.5 mt long 3 b ) stp 11 mtr long. 4 c ) line material such as stay rod, stay wire, acsr weasel, acsr rabbit conductor, gi wire, ms chennel, ms angle. etc 5 cartage of following from je store to site of work including loading& unloading at both ends maximum distance up to 40 km.a ) pcc / pole 8.5 mt long 6 b ) stp 11 mtr long. 7 c ) line material such as stay rod, stay wire, acsr weasel, acsr rabbit conductor, gi wire, ms chennel, ms angle. etc 8 erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.5 mtr in all type of soil including back filling of the pole with proper ramming including fixing of lt& ht line accessories 9 erection of st pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.5 mtr in all type of soil including back filling of the pole with proper ramming including fixing of lt& ht line accessories 10 fabrication & fixing of 11 kv cross arms of ms angle iron of size 65x65x6 mm traightening, cutting and drilling the holes. 11 guarding of line with g.i. wire having 2 nohorizontal wire& 3 mt distance odf laces of ten swg g.i wire after fabrication of guard cross arms of& fixing the same in supports. 12 repairing of old & rusted guarding of line with g.i. wire having 2 nohorizontal wire& 3 mt distance odf laces of ten swg g.i wire after fabrication of guard cross arms of& fixing the same in 13 providing & fixing bamboo strips in 3 phase 4 wire in lt line with proper binding. 14 cutting & chopping of tree branches near side of line for making clearance beetween line & tree. 15 re sagging of lose sag of lt line & ht line after opening the bindings then stringing the conductor & rebinding jumpring the same properly. 16 providing and fixing the plastic sheet around the steel round pole / rs joist / rail up to 7 height from bottem of pole to avoide any misshappenings due to earth fault as per instruction of higher authorities. 17 straightening of tilled pcc pole of 11 kv / lt lines after opening the bindings from insulators and digging the pit for require depth and refilling the same pit after completion of work including rebinding the conductor with insulators & sagging the conductor. 18 reparing of lt leads of medum power t / f with ht tape empire tape and pvc tape. 19 replacment of dameged lt pvc lead of size 1x400 sq. mm. 20 reparing of damaged & missing part of fencing of medum power t / f plinth. 21 baracating of medium power t / f at various places at road side with the help fo wooden balli. card bord & bamboo etc. 22 replacment & reparing of old & rusted jumpers of 11 kv & lt line. 23 fixing of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.8 mt and grouting the same in block of size 0.60 x 0.60 x 0.30 mt and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 24 replacement of damage & burnt conductor of lt line with conductor including opening the bindings & removal of damage conductor & making the role then laying lifting sagging & stringing of new conductor with proper bindings & jumprings.as follows: a ) . acsr wieasel conductor. 25 earthing of stp properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 26 providing and fixing stay clamps with nuts & bolts. 27 providing and fixing stay insulator with nuts & bolts. 28 providing and fixing holding clamps with nuts & bolts. 29 providing and fixing f brecket with nuts & bolts 30 grouting of st pole in block of size 0.45x0.45x1.5 mtrs. in cc 1:4:8 with cement, sand & brick ballast. ( all material shall be providing by the contractor ) 31 laying of lt abc cable of size 3x503x95x3x120...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32836503 regarding erection of pole in long span, guarding of line and fixing pvc sheer on steel pole and strengthening of 11 kv lt line at kawar marg in under the area of edd i mawana= 1 cartage of following from store center meerut to je store including loading& unloading at both ends maximum distance up to 40 km. 2 a ) pcc pole 8.5 mt long 3 b ) stp 11 mtr long. 4 c ) line material such as stay rod, stay wire, acsr weasel, acsr rabbit conductor, gi wire, ms chennel, ms angle. etc 5 cartage of following from je store to site of work including loading& unloading at both ends maximum distance up to 40 km.a ) pcc / pole 8.5 mt long 6 b ) stp 11 mtr long. 7 c ) line material such as stay rod, stay wire, acsr weasel, acsr rabbit conductor, gi wire, ms chennel, ms angle. etc 8 erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.5 mtr in all type of soil including back filling of the pole with proper ramming including fixing of lt& ht line accessories 9 erection of st pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.5 mtr in all type of soil including back filling of the pole with proper ramming including fixing of lt& ht line accessories 10 fabrication & fixing of 11 kv cross arms of ms angle iron fo size 65x65x6 mm traightening, cutting and drilling the holes. 11 guarding of line with g.i. wire having 2 nohorizontal wire& 3 mt distance odf laces of ten swg g.i wire after fabrication of guard cross arms of& fixing the same in supports. 12 repairing of old & rusted guarding of line with g.i. wire having 2 nohorizontal wire& 3 mt distance odf laces of ten swg g.i wire after fabrication of guard cross arms of& fixing the same in 13 providing & fixing bamboo strips in 3 phase 4 wire in lt line with proper binding. 14 cutting & chopping of tree branches near side of line for making clearance beetween line & tree. 15 re sagging of lose sag of lt line & ht line after opening the bindings then stringing the conductor & rebinding jumpring the same properly. 16 providing and fixing the plastic sheet around the steel round pole / rs joist / rail up to 7 height from bottem of pole to avoide any misshappenings due to earth fault as per instruction of higher authorities. 17 straightening of tilled pcc pole of 11 kv / lt lines after opening the bindings from insulators and digging the pit for require depth and refilling the same pit after completion of work including rebinding the conductor with insulators & sagging the conductor. 18 reparing of lt leads of medum power t / f with ht tape empire tape and pvc tape. 19 replacment of dameged lt pvc lead of size 1x400 sq. mm. 20 reparing of damaged & missing part of fencing of medum power t / f plinth. 21 baracating of medium power t / f at various places at road side with the help fo wooden balli. card bord & bamboo etc. 22 replacment & reparing of old & rusted jumpers of 11 kv & lt line. 23 fixing of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.8 mt and grouting the same in block of size 0.60 x 0.60 x 0.30 mt and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 24 replacement of damage & burnt conductor of lt line with conductor including opening the bindings & removal of damage conductor & making the role then laying lifting sagging & stringing of new conductor with proper bindings & jumprings.as follows: a ) . acsr wieasel conductor. 25 earthing of stp properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 26 providing and fixing stay clamps with nuts & bolts. 27 providing and fixing stay insulator with nuts & bolts. 28 providing and fixing holding clamps with nuts & bolts. 29 providing and fixing f brecket with nuts & bolts 30 grouting of st pole in block of size 0.45x0.45x1.5 mtrs. in cc 1:4:8 with cement, sand & brick ballast. ( all material shall be providing by the contractor ) 31 laying of lt abc cable of size 3x503x95x3x120...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32683302 regarding release 500kva ( lmv 2 ) new connection of m / s dfccrl care of sh. mahaviir singh add. 3rd building shri balaji complex ved vyas puri near subharti university site khasra no. 44 village kanoda near sakoti underedsd i, dauralaunder edd ii, meerut, under edc 2 meerut 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. :– 2 a ) stp pole 11 mtrlong. 3 b ) 11 kv vcb o / g 4 c ) 11kv ct / pt unit 5 d ) 11 kv meter cubical 6 e ) 11 kv xlpe cable size 3x185 sqmm. / 3x120 sq.mm. 7 cartage of line material from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 40 km. 8 cartage of following material fromje store to site of work including loading & unloading at both ends maximum distance up to 20 km. :–a ) stp pole 11 mtr long. 9 erection ofdppole on stp 11 mtr. long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work with fabrication and fixing all line accessories. 10 erection ofsinglepole on stp 11 mtr / 13 mtr . long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work with fabrication and fixing all line accessories. 11 laying lifting stringing of proper sagging of acsr dogconductor 12 digging the cable trunch fordouble circuit 11kv cable. 13 laying of 11 kv xlpe cable size 3x185 sqmm. / 3x120 sq.mm. 14 fixing of 11 kv heat shrinkable cable jointing kits 15 erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 16 grouting of stp poles with dust, cement & stone blast concreting. 17 cutting & chopping tree branches near side of line for making the clearance between line and tree. 18 water level earthing for o / g vcb and 11 kv meter cubical 19 earting of each 11 kv line pople & t / f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 20 mounting of 11 kv ct / pt unit on double pole with making connection properly. 21 grouting of o / g vcb and making connection properly 22 grouting of 11 kv meter cubical properly 23 providing and fixing stay clamps . 24 providing and fixing holding clamps . 25 providing and fixing f clamps . 26 providing and fixing bolt and nuts . 27 providing and fixing hdpe type pipe for 11 kv rod crossing...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

31975921 system improvement works at different sites in the area of edsd i, medical and edsd ii, kithore under edd iv, meerut= 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. : 2 cartage of 63 / 100 kva t / f from store centre meerut to je store includig loading and unloading at both ends 3 mounting of 63 / 100 kva t / f from where existing t / f has been dmountened with proper jumpring of ht side and fixing of cable on lt side of t / f 4 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 40 km. : 5 cartage of 8.5 mtr. long pcc pole 6 line materials such as & weasel conductor, ms channel ( 100x50x2028 ) mm, holding clamps, tpmo& fuse set, ms angle 75x75x6x20x25 mm, ms channel 125x65x2240, t channel, 11 kv disc insulator, 11 kv pin insulator with pin, stay set complete, distributioon box single phase and three phase, tee off channel, lt abc ( 3x95x+1x75+1x16 ) ) sq.mm, j hook, ms nuts and bolts, t shackle insulator, 11 kv disc insulator with fitting, 11 kv pin insulator with pin etc. 7 erection of pcc pole 8.5 mtr long / stp pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of soil including back filling of the pole with proper ramming after completion of work. 8 fabrication and fixing of all 11 kv ht / lt line accessories. 9 erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 10 erection of double pole on pcc pole 8.5 mtr after digging a pit of size1.6 mtr deep in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 11 earthing of each 11 kv line pole properly after drive of electrodes of size 20mm x 2500 mm and connection the earthing point with gl wire. 12 grouting of pcc / stp pole 13 cutting and chopping tree branches near side of line for making the clearance between line and tree...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

31963375 regarding construction of 33 kv new line s / s. niwari road to modinagar 33 / 11 kv s / s. gejha 33 kv line 132 kv s / s. new line gejha 220 gejha, raghunathpur under edsd iii, bhola under edd iii, meerut ( system improvement works 2022 23 ) 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. : 2 pcc pole 8.5 mtr long / st pole 11 mtr. long. 3 line material such as 33 kv cross arms 33 kv pin, 33 kv pin insulator, 33 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 4 33 kv v type ms x arm 5 33 kv cable jointing kit 6 xlpe 33 kv cable 3x70 to 185 mm 7 33 kv pin insulator with pin 8 33 kv disc with fitting 9 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 40 km. : 10 pcc pole 8.5 mtr long / st pole 11 mtr. long. 11 line material such as 33 kv cross arms 11 kv pin, 33 kv pin insulator, 33 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 12 33 kv v type ms x arm 13 33 kv cable jointing kit 14 xlpe 33 kv cable 3x70 to 185 mm 15 33 kv pin insulator with pin 16 33 kv disc with fitting 17 erection of pcc pole 8.5 mtr long / stp pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 18 fabrication and fixing of all 33 kv ht / lt line accessories. 19 erection of double pole on pcc pole 11 mtr after digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 20 fabrication and fixing of all 33 kv ht / lt line accessories. 21 erection offour pole on 11 mtr after digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 22 fabrication of t off channel 23 fabrication and fixing of ms angle and ms channel, fixing all 33 kv line for pole etc work 24 erection of stay rod complete after digging a pit of size 1.20 x0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 25 laying lifting stringing of proper sagging of acsr dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 26 laying lifting & sagging of 33 kv line with acsr dog conductor including proper binding & jumpring. 27 earthingh of each 33 kv line pople & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 28 guarding of line with g.i. wire having 2 no. horizontal wire & 3 mtr distance odf laces of ten swg g.i. wire after fabrication of guard cross arms of & fixing the same in supports. 29 cutting & chopping tree branches near side of line for making the clearance between line and tree. 30 33 kv line of grouting 31 xlpe cable laying 3x300 sqmm pit trench under ground laying lifting at air 32 filling 33 kv cable box o / d type 33 providing and fixing stay clamps. 34 providing and fixing holding clamps. 35 providing and fixing pg clamps. 36 providing and fixing bolt and nuts. 37 providing and fixing of g.i. pipe 38 danger borad 39 barbed wire 40 33 kv line guarding road crossing river corssing etc work...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

31934231 regarding maintenance of old and damage underground xlpe 11kv 3x185 sq.mm. at 33 / 11 kv s / s churrand given new 40 h.p connection of adishashi adhikari nagar panchayat harra under edsd ii sardhana town under edd ii meerut, under edc 2, meerut. 1 a ) 11kv xlpe cable 3x185 sqmm. at churr. 2 cartage of xlpe 3x185 sq.mm 11kv cable from center store to je store including loading & unloading at both ends maximum distance up to 40 km :– 3 cartage of xlpe 3x185 sq.mm 11kv cablefromje store to site of work including loading & unloading at both ends maximum distance up to 20 km :– 4 digging of cable trench of size 0.50 in to 0.750 mtr. depth width digging the earth for loop at both ends. 5 laying of 11kvxlpe cable 3x185 sq mm. cable in trench. 6 felling the trench width executed earth width proper dressing. 7 fixing the jointing kit ( straight threw ) of 3x185 sq mm. 8 given new 40 h.p connection of adishashi adhikari nagar panchayat harra.cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. :–a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 9 b ) 11 kv xlpe 3x70 sqmm. cable 10 c ) 63 kva transformer 11 cartage of line material from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 20 km. 12 cartage of following material from je store to site of work including loading & unloading at both ends maximum distance up to 20 km. :– a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 13 b ) 11 kv xlpe 3x70 sqmm. cable 14 c ) 63 kva transformer 15 erection ofpcc pole 8.5 mtr long / stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 16 fabrication and fixing of all 11 kv h.t / l.t. line accessories. 17 erection of double pole on pcc pole 8.5 mtr after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators and making connection properly. 18 fabrication and fixing of top channel, dropper channel transformer base angle fuse set, tpmo etc. 19 earting of each 11 kv line pople & t / f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 20 mounting of 63 kva with proper jumping of ht side and fixing of cable on lt. side of t / f making connection properly. 21 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 22 erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 23 laying of overhead cable on pcc pole 11kv xlpe cable 3x70 sqmm 24 felling the jointing kit 11kv xlpe cable 3x70 sqmm 25 grouting of pcc / st poles with dust, cement & stone blast concreting. 26 providing and fixing stay clamps . 27 providing and fixing holding clamps . 28 providing and fixing lt clamps . 29 providing and fixing bolt and nuts ....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

30630582 regarding running contract of new and old 11 kv and lt line work under system improvement against sanction estimate or linkage / package work in the area of edsd i, daurala / edsd ii sardhana town / edsd iii sardhana dehat under edd ii, meerut under edc 2, pallavpuram, meerut. 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. :– 2 a ) pcc pole8.5 mrt long / st pole 11 mtr long. 3 b ) 25 kv to 100 kv t / f including complete related material required for transformer. 10 kv to 100 kv t / f including complete related material required for transformer. 4 cartage of 250 kv transform from store centre meerut to je storeincluding loading & unloading at both ends maximum distance up to 40 km. :– 5 line materials such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. ( 15 qtl. ) 6 cartage of following material from je store to site of work including loading & unloading at both ends maximum distance up to 40 km. :– a ) pcc pole8.5 mrt long / st pole 11 mtr long. 7 b ) 25 kv to 100 kv t / f including complete related material required for transformer. 10 kv to 100 kv t / f including complete related material required for transformer. 8 cartage of 250 kv transform from je storeto site of workincluding loading & unloading at both ends maximum distance up to 20 km. :– 9 erection ofpcc pole 8.5 mtr long / stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 10 fabrication and fixing of all 11 kv h.t / l.t. line accessories. 11 erection of double pole on pcc pole 8.5 mtr after digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 12 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators. 13 mounting of 25 to 100 kva t / f with proper jumping of ht side and fixing of cable on lt. side of t / f . 14 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 15 erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 16 laying lifting stringing of proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 17 laying lifting stringing of proper sagging of acsr rabbit conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 18 laying lifting & sagging of lt line with a.c.s.r. weaseal / rabbit conductor including proper binding & jumpring: a ) 3 phase 4 wire line. 19 b ) 2 phase 3 wire line. 20 c ) 1 phase 2 wire line 21 eartingh of each 11 kv line pople & t / f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 22 removeal of old & damaged conductor from l.t. / h.t. line by opening the bindings jumpers & making its roll including proper stacking at site. 23 dissmentling of damaged & broken p.c.c. / s.t.pole / r.s. joist by digging the pits & removel of complete h.t. / l.t. line accessories . 24 grouting of pcc / st poles with dust, cement & stone blast concreting. 25 guarding of line with g.i. wire, 8 swg and 10 swghaving 2 no horizontal wire & 3 mtr. distance of laces of ten 8 swg g.i wire after fixing the guard cross arm. 26 cutting & chopping tree branches near side of line for making the clearance between line and tree. 27 providing and fixing stay clamps . 28 providing and fixing holding clamps . 29 providing and fixing f clamps . 30 providing and fixing lt clamps . 31 providing and fixing ltinsulator clamps . 32 providing and fixing bolt and nuts . 33 construcation of new plinth for 250 kva t / f 34 providing & fixing wiremess fancing for 250 kva t / f 35 pipe earthing 60 feet for 250 kva t / f ( neutral and body ) 36 back cartage of 100 kva t / ffrom site to center store meerut....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

30547444 business plan works different sites in the area of edsd iii bhola under edd iii meerut cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. : 2 st pole 11 mtr. long. / pcc pole 8.5 mtr long 3 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 4 acsr weasel conductor 5 lt pvc cable all sizes 6 250 kva transformer 7 25 kva to 100 kva transformer 8 cartage of following material from je, store to site of work including loading & unloading at both ends maximum distance up to 15 km. : 9 st pole 11 mtr. long. / pcc pole 8.5 mtr long 10 line material such as 11 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel conductor, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 11 acsr weasel conductor 12 lt pvc cable all sizes 13 250 kva transformer 14 25 kva to 100 kva transformer 15 erection of stp pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 16 fabrication and fixing of all 11 kv ht line accessories. 17 erection of double pole on stp11 mtr after digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole including back filling of the pole with proper ramming after completion of work. 18 fixing of 11 kv tpmo with on existing on double pole 19 fixing of 11 kv fuse set with on existing on double pole 20 fabrication and fixing of ms angle and ms channel, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators. 21 opening and binding st jumper 100 kva and 25 kva and 63 kva t / f after dismental 22 mounting of 25 to 100 kva t / f with proper jumping of ht side and fixing of cable on lt side of t / f. 23 earthingh of each 11 kv line pople & t / f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 24 mounting of plinth 250 kva transformer grouting of stp pole with bb concreeting in block of size 0.45x0.45x1.6 mtr in reso of 1:4:8 of cement send and brick ballast 25 construction of 250 kva transformer foundation of plinth. 26 frp fencing for 250 kva transformer and grouting plinth and fencing etc. work. 27 water level earthing with gi pipe 32 mm dia and ms flat of size 45x5mm 28 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 29 erection of stay rod complete after digging a pit of size 1.20 x0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 30 cutting & chopping tree branches near side of line for making the clearance between line and tree. 31 fixing and lifting of lt distribution box 3 ph. single phase lt line 32 pvc lead and joint the connection of lt distribution box 33 providing and fixing stay clamps. 34 providing and fixing holding clamps. 35 providing and fixing f clamps. 36 providing and fixing bolt and nuts. 37 dissmentling of 25 kva to 100 kva transformer old and use ( scrap ) in je, store...

Urban Development Department - Uttar Pradesh

30407410 bids are invited for supply & fixing of 7 mtr gl octagonal pole of approved make bottom dia 130mm ( top dia 70mm, and base plate 12mm thik ) having 3mm thickness with supply & fixing of 7 mtr gl octagonal pole , supply & fixing of factory wired integral led street light luminaries with die cast aluminium housing built with driver set suitable for 72 watt supply & fixing of factory wired integral led street light luminaries , supply & laying of aluminium coductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75mm. supply & laying of aluminium coductor pvc insulated armoured , supply & laying of aluminium coductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75mm. . supply & laying of aluminium coductor pvc insulated armoured served sheathed cables 1100 volts , supply & fixing of ( 450x450 ) mm size redium reflective sign board of nagar panchayat all complete as per direction supply & fixing of ( 450x450 ) mm size redium reflective sign , providing and fixing 6 swg dia gl wire on surface or in recess for loap 6earthing along with exciting surface / recessed conduit / sub main wiring / cable as required. providing and fixing 6 swg dia gl wire on surface , supply & laying of following size capacity of automatic street light cubicle control panel painted with anti corossive alkali and acid proof paint consisting of time supply & laying of following size capacity of automatic street light , supply & buring of safe earthing electrode t 19, ( hot dip galvanized ) , |length up to 3000mm, outer dia 50 mm inner dia 25 mm, supply & buring of safe earthing electrode t 19 , providing and fixing ( 25x3 ) mm gi strip in 40mm dia gl pipe from earth 9electrode including connection with gl nut bolt spring warsher excavation and refillink etc as required. providing and fixing ( 25x3 ) mm gi strip in 40mm dia gl pipe , supply and wiring of submains with two nos. of 2.5 sq. mm frlsh pvc insulated 1100 v grade signle core multistrand copper conductor cable in supply and wiring of submains with two nos. of 2.5 sq. mm , dismentalling of interlocking road with all labour complete. 2520 ( .60x600 ) =360 dismentalling of interlocking road , excavation of earth for laying cable line work in soil mixed with moorum, kankar and shinjle etc including lift upto .5 mtr and lead upto 50 mtr and excavation of earth for laying cable , reinstatement of the interlocking road by watering, ramming & consolidation of the trenches complete including all metarial, labour t&p reinstatement of the interlocking , s / l spriting & compacting 22.4 mm to 53 mm 14 stone ballast and fine send including mixer all complete ( 600x.60xo.08 ) =28.8 s / l spriting & compacting 22.4 mm to 53 total quantity : 1...

Urban Development Department - Uttar Pradesh

30400673 bids are invited for supply & fixing of 7 mtr gi octagonal pole of approved make ( top dia 70mm, bottom dia 130mm and base plate 12mm thik ) having 3mm thickness supply & fixing of 7 mtr gi octagonal pole , supply & fixing of factory wired integral led street light luminaries with die cast aluminium housing built with driver set suitable for 72 watt. supply & fixing of factory wired integral led street light luminaries , supply& laying of aluminium coductor pvc insulated armoured served |sheathed cables 1100 volts grade at a depth of 750 mm belowground level over a cushion of 75mm. supply& laying of aluminium coductor pvc insulated , upply& laying of following size dwc hdep pipe isi mark along with all accessories like socket bend cuppler ete confirming to is 14930 part second upply& laying of following size dwc hdep pipe isi mark , supply & fixing of ( 450x450 ) mm size redium reflective sign board of nagar panchayat all complete as per direction supply & fixing of ( 450x450 ) mm size redium reflective sign board , providing and fixing 6 swg dia gl wire on surface or in recess for loap 6 earthing along with exciting surface / recessed conduit / sub providing and fixing 6 swg dia gl wire on surface , supply & laying of following size capacity of automatic street light cubicle control panel painted with anti corossive alkali supply & laying of following size capacity of automatic street light , supply & buring of safe earthing electrode t 19, ( hot dip galvanized ) , length up to 3000mm, outer dia 50 mm inner dia 25 mm, terminal dia 12mm, supply & buring of safe earthing electrode t 19 , providing and fixing ( 25x3 ) mm gi strip in 40mm dia gi pipe from earth 9 electrode including connection with gl nut bolt spring providing and fixing ( 25x3 ) mm gi strip in 40mm dia gi pipe , supply and wiring of submains with two nos. of 2.5 sq. mm frlsh pvc insulated 1100 v grade signle core multistrand copper conductor cable supply and wiring of submains with two nos. of 2.5 sq. mm , dismentalling of interlocking road with all labour complete. 600x.60 ) 360 dismentalling of interlocking road with all labour complete , excavation of earth for laying cable line work in soil mixed with moorum, kankar and shinjje etc including lift upto .5 mtr and lead upto 50 mtr excavation of earth for laying cable line work in soil mixed , reinstatement of the interlocking road by watering., ramming& consolidation of the trenches complete including all metarial, labour t&p 13 etc complete as per requiment. reinstatement of the interlocking road by watering , s / l spriting& compacting 22.4 mm to 53 mm 14 stone ballast and fine send including mixer all complete ( 600x.60xo.08 ) =28.8 s / l spriting& compacting 22.4 mm to 53 mm 14 stone ballast total quantity : 1...

Urban Development Department - Uttar Pradesh

30399980 bids are invited for supply & fixing of 7 mtr gl octagonal pole of approved make bottom dia 130mm ( top dia 70mm, and base plate 12mm thik ) having 3mm thickness with supply & fixing of 7 mtr gl octagonal pole , supply & fixing of factory wired integral led street light luminaries with die cast aluminium housing built with driver set suitable for 72 watt supply & fixing of factory wired integral led street light luminaries , supply & laying of aluminium coductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75mm. supply & laying of aluminium coductor pvc insulated armoured , supply & laying of aluminium coductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75mm. . supply & laying of aluminium coductor pvc insulated armoured served sheathed cables 1100 volts , supply & fixing of ( 450x450 ) mm size redium reflective sign board of nagar panchayat all complete as per direction supply & fixing of ( 450x450 ) mm size redium reflective sign , providing and fixing 6 swg dia gl wire on surface or in recess for loap 6earthing along with exciting surface / recessed conduit / sub main wiring / cable as required. providing and fixing 6 swg dia gl wire on surface , supply & laying of following size capacity of automatic street light cubicle control panel painted with anti corossive alkali and acid proof paint consisting of time supply & laying of following size capacity of automatic street light , supply & buring of safe earthing electrode t 19, ( hot dip galvanized ) , |length up to 3000mm, outer dia 50 mm inner dia 25 mm, supply & buring of safe earthing electrode t 19 , providing and fixing ( 25x3 ) mm gi strip in 40mm dia gl pipe from earth 9electrode including connection with gl nut bolt spring warsher excavation and refillink etc as required. providing and fixing ( 25x3 ) mm gi strip in 40mm dia gl pipe , supply and wiring of submains with two nos. of 2.5 sq. mm frlsh pvc insulated 1100 v grade signle core multistrand copper conductor cable in supply and wiring of submains with two nos. of 2.5 sq. mm , dismentalling of interlocking road with all labour complete. 2520 ( .60x600 ) =360 dismentalling of interlocking road , excavation of earth for laying cable line work in soil mixed with moorum, kankar and shinjle etc including lift upto .5 mtr and lead upto 50 mtr and excavation of earth for laying cable , reinstatement of the interlocking road by watering, ramming & consolidation of the trenches complete including all metarial, labour t&p reinstatement of the interlocking , s / l spriting & compacting 22.4 mm to 53 mm 14 stone ballast and fine send including mixer all complete ( 600x.60xo.08 ) =28.8 s / l spriting & compacting 22.4 mm to 53 total quantity : 1...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

29142080 deposit works at different sites in the area of edsd ii partapur under edd i meerut cartage of 25 no. pcc poles from store centre meerut to dump at site including loading & unloading 2 cartage of line material ( conductor, ms channel, 11 kv disc insulator etc.) from store centre to dump site (work will be carried out round) 3 cartage of 10 to 100 kva t/f meerut to dump at site including loading & unloading 4 erection of double pole on pcc pole by digging the pit and fixing of all accessories such as top and droper channel and required 11 kv accessories including mounting of t/f with ht side jumper and fixing of lv pvc lead 5 cartage complete related material required for transformer 10 to 100 kva 6 laying, lifting stringing of proper sagging of acsr weasal conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly 7 fixing of distribution box including fixing the cable from transformer and consumer service cable 8 making a section pole to exist pole after fabricating & fixing of t channel fixing of all accessories 9 grouting of pcc pole 10 grouting of stay set 11 erection of single pole 12 laying, lifting and sagging of 11 kv xlpe/lt abc 13 earthing of each 11 kv line pople & t/f properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with gl wire. 14 providing and fixing holding clamp 15 providing and fixing lt clamp 16 providing and fixing nut & bolts 17 cutting & chopping tree branches near side of line for making the clearance between line and tree. t...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

28051866 tender for breakdown and damage pole work 2 carriage of fallowings from esc. bsr to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 kms. 3 pcc / stp from e.s.c bulandshahr to site. 4 carriage of all line material from store to j.e store sub station as acsr weasel conductor, abc conductor gi wire, earth wire. m.s. chanel, angle, stay & earthig rods, barbed wire. disc insulator etc. 5 erection of single support including complete 1 it fittings as per respo manual and as per direction of engineer in charge including the cost of labour, t&p and carrier etc. required for proper completion of work. 6 grouting of single support shall be grouted with cement, sand and birck ballast / stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast / stone ballast, etc. as per actual size requirement, as per respo manual and as per direction of engineer in charge including the cost of labour, t&p and carrier etc. required for proper completion of work. 7 carriage of all line material from store to j.e store sub station as acsr weasel conductor, abc conductor gi wire, earth wire. m.s. chanel, angle, stay & earthig rods, barbed wire. disc insulator etc 8 laying, sagging. stringing and binding and jumpering of acsr weasel conductor on the newly erected pole as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t&p, carrier etc. requried for proper completion of work. 9 fixing of stay rod with stay wire in proper way with nozelling. 10 grouting of stay rods . 11 guarding of 11 k v line at road crossing by laying 3 nos. gl wire of size 6 / 10 swg parallel and fixing of lacings ( tilli ) at a distance at 1.5 mlrs as per direction of supervising engineer / respo mannual it. includes the cost of labour, t&p carrier etc. required lor proper completing of work. 12 resagging of loose and bad sag of l.t. / h.t. line. 13 chopping of tree branches.. 14 tightening of stay 15 grouting of pcc / stp pole old 16 change of broken / damaged / missing following items : 17 disc insulator 18 nut & bolt off size 19 bended x arm / angle / channel 20 ailment of pcc / stp pole 21 stay clamps 22 d.p. clamp 23 stay insulator 24 making of plinth of the damaged / broken stp of the welded 03 nos. angle iron piece with the pole. 25 the following material is required to be the following material is required to be supplied by the contractor. 26 stay clamp. 27 stay insulator. 28 l.t. clamp. 29 l.t. shackle insulator. 30 l.t. insulator bolt 6 ench. 31 f clamp. 32 double pole clamp. 33 holding clamp. 34 bolt & nut off size....

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

27714055 regarding system improvement work against sanctioned linkage / package at different site in the area of edsd i, parikshitgarh, of edd ii, mawana under edc 2, meerut 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 30 km. :– 2 a ) stp pole 11 mtr. long 3 cartage of line material from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km. 4 cartage of following from dump site to site of work on day to day basis including loading & unloading at both ends maximum distance up to 30 km :– na ) stp pole 11 mtr. long. 5 cartage of 63 kva t / f. from store center meerut to dump site including loading & unloading at both ends maximum distance up to 30 km. 6 making plinth suitable for 250 kva ( 3 x2x1 mtr. ) transformer alongwith plaster & paint complete work in all respect. 7 providing & fixing of wiremess fancing around the plinth of 250 kva t / f ( 3 x2x1 mtr. ) 8 water level earthing of t / f ( neutral & body ) after providing of g.i pipe 32mm dia and ms. flat 35x5mm up to 20 mtr depth complet work in all respect. 9 dismanteling of stp pole 11 mtr. after opening the bindings and making coil of acsr dog conductor 250 mtr. 10 erection of stp pole 11 mtr. long after digging a pits of required size with fixing line accessories complete. 11 laying lifting, sagging and binding of acsr dog conductor. 12 earthing of each 11 kv line pole & t / f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 13 providing & fixing nut and bolt 14 dismanteling of 25 kva t / f from double pole after opening the jumper & connections 15 making connections and jumper by acsr weasel conductor 16 fixing of 11 kv disc insulator 17 fixing of pin insulator 18 fabrication and fixing of ms channel 100x50x2028 sq.mm. for dropper 19 fabrication and fixing of ms channel 75x75x6x2028 sq.mm. with nut & bolt for transformer base channel. 20 mounting of 63 kva t / f double pole and making connections properly by pvc cable complete work in all respect. 21 grouting & fixing of stay set 22 fixing of tpmo 23 fixing of fuse set 24 back cartage of old & used material from site of work to je store and then store centre meerut distance upto 30 km. as follow: na ) 25 kva t / f 25 b ) stp pole 26 c ) acsr dog conductor...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

27059695 regarding repair & construction work of old & new line under full deposit work scheme in the area of edsd i, parikshitgarh under edd ii, mawana 1 cartage of following material from store center meerut to je store including loading & unloading at both ends maximum distance up to 40 km. :– 2 a ) pcc pole 8.5 mrt long / st pole 11 mtr long. 3 cartage of line material from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 20 km. ( 15 qtl. ) 4 cartage of 10 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site 5 cartage of following material from je store to site of work including loading & unloading at both ends maximum distance up to 40 km. :– a ) pcc pole8.5 mrt long / st pole 11 mtr long. 6 safe cartage of ct / pt of diffrent ratio from store centre meerut to site of work including loading and unloading at both ends. 7 dissmentling of damaged & broken p.c.c. / s.t.pole / r.s. joist by digging the pits & removel of complete h.t. / l.t. line accessories . 8 eartingh of each 11 kv line pople & t / f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 9 erection of pcc pole 8.5 mtr long / stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 10 fabrication and fixing of all 11 kv h.t / l.t. line accessories. 11 erection of double pole on pcc pole 8.5 mtr after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories tpmo, fuse set 11 kv pin insulators and making connection properly. 12 mounting of 10 to 100 kva t / f with proper jumping of ht side and fixing of cable on lt. side of t / f making connection properly. 13 making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories. 14 erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 15 laying lifting stringing of proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 16 laying lifting stringing of proper sagging of acsr rabbit conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 17 laying lifting & sagging of lt line with a.c.s.r. weaseal / rabbit conductor including proper binding & jumpring: na ) 3 phase 4 wire line. 18 b ) 2 phase 3 wire line. 19 c ) 1 phase 2 wire line 20 guarding of line with g.i. wire having 2 no horizontal wire& 3 mtr distance odf laces of ten swg g.i wire after fabrication of guard cross arms of & fixing the same in supports. 21 cutting & chopping tree branches near side of line for making the clearance between line and tree ( near about 100 branches ) . 22 fixing of lt distribution box along with providing clamp nut & bolts 23 providing and fixing stay clamps . 24 providing and fixing holding clamps . 25 providing and fixing lt clamps . 26 providing and fixing lt insulator clamps . 27 providing and fixing bolt and nuts . 28 installation of ct / pt & making connection properly 29 fixing of 11 kv heat shrinkable cable jointing kits...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

23336313 regarding various work in section estimate under full deposit scheme in the area of edsd sardhana town & edsd sardhana dehat under edd ii meerut 2 cartage of following material from store center, meerut to je store including loading & unloading at both ends maximum distance up to 40 km. :– na ) pcc pole 8.5 mtr. long. 3 b ) st pole 11 mtr. long. 4 c ) line materials such as 33 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel / rabbit conductor, lt abc, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 5 cartage of following material from je store to site of work including loading & unloading at both ends maximum distance up to 40 km. :– na ) pcc pole 8.5 mtr. long. 6 b ) st pole 11 mtr. long. 7 c ) line materials such as 33 kv cross arms 11 kv pin, 11 kv pin insulator, 11 kv disc, stay rod, stay wire acsr weasel / rabbit conductor, lt abc, gi wire, ms angle iron & ms channel, tpmo, fuse set etc. 8 erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work. 9 erection of st pole after digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole including fabrication and fixing of all accesries after completion of work. n1. 11 kv line – 01 no. n2. 33 kv line – 03 no. 10 making a double pole on pcc pole after digging a pits of size 1.20 x 0.60 x 1.6 mtr in all type of soil for each pole. 11 binding of barbed wire and danger plate 12 fabrication and fixing of ms angle and ms channel, n ( top, dropper, base channel for 03 nos double pole ) 13 fabrication and fixing of t off channel 04 nos. 14 11 kv accessories tpmo, 15 fixing of 11 kv fuse set 16 erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 17 laying lifting stringing of proper sagging of acsr weasel conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 18 laying lifting stringing of proper sagging of acsr dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly. 19 cutting & chopping tree branches near side of line for making the clearance between line and tree. 20 fabrication & fixing of guarding angle for proper guarding after binding of g.i. wire and including binding slaces in equal distance. 21 earthing of each 11 kv line & double pole & t / f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gl wire. 22 grouting of pcc pole 8.5 mtr. / st pole 11 mtr. long as per respo. 23 mounting of 10, 25, 63 kva t / f with proper jumping of ht side and fixing of cable on lt. side of t / f . 24 dismantling of old lines by digging of pits & opening the binding and removal of conductor including making its roll and proper stacking at site: n ( a ) pcc pole 02 nos n 25 ( b ) old conductor ( 120 mtr. ) , 26 ( c ) insulator 06 nos., 27 back cartage of removed and dismantiled material from site to je store as follows: n ( a ) pcc pole 06 nos n 28 ( b ) old conductor ( 120 mtr ) n 29 ( c ) abc cable ( 70 mtr ) n 30 ( d ) insulator 06 nos. n 31 ( e ) 33 kv pin insulator 09 nos. 32 providing and fixing clamps off size. 33 fixing of 33 kv cross arm 34 providing and fixing bolt and nuts off size....

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

23111040 various work under business plan and other work under edd iii aligarh cartage of following poles store centre or from any other place to the respective site of work through the kachha pacca road including the work of its loading & unloading at the respective ends also including the work of dragging etc. and also including the cost of labour, t&p carrier etc. required for proper completion of work. ( dist. 0 to 50 kms. ) . 1.01 pcc poles 8.5 mtr.ist pole 11 mtr. 2 cartage of line material viz weasal condudtor, gl earth wire, cross arm, angle, channel, insulator, clamps & other line material from store centre or from any other place to the respedtive site of work through the kachha pacca road including the work of its loading & unloading at the respedtive ends also including the work of dragging etc. and also including the cost of labour, t&p carrier etc. required for proper completion of work. ( dist. 0 to 50 kms. ) . 3 erection of single support including complete h.t / l.t fittings as per respo manual and as per diredtion of engineer incharge including the cost of labour, t & p and carrier etc. required for proper 3.01 completion of work. — pcc poles 8.5 utr. / st pole 11 mtr. & 3 erecaion of 11i1kv line douale pole on pcc / s4palw including the work of complete line as per respo 4 norm manual and as per direction or engmeer lncharge including the cost of labour, t & p and carrier etc. required for proper completion of work. 4.01 pcc poles 8.5 m1tr. / st pole 11 mtr. 4.02 installation & fixing of 11 1kv tpmo laying. sagging. stringing. binding and jumpering — etc. of old line condudtor on the newly erected pole as per respo manual and as per direction of supervising engineer, including the cost of arrangement of labour, t&p carrier etc. required for ___________ proper completion ot work. 5.01 acsr weasal condudtor — 5.02 acsr dog conductor drilling and culling of tee off channel, v cross arms, top channel, cross bracing angle, ms 6 garding angle, dropper chanel. as per specification of uppcl construdtion manual including including loading and unloading at the , nth anjdlc — grouting of pcc / st poles as per respo norms 7 including cost of grouting material ( cement sand: brick ballast ) size 1s00x450x45o mm ) . — 8 making the plinth or st pole 11 mtr. chopping of tree branches which are touching to 11 kvilthnes. dismantling and removal of existing conductor from the vanous area preparing their coils and 10 then stacking in the respective je’s ( store ) as per direction of supervising engineer. it inducles the work of cartage, cost of labour, t&p carrier etc. required for proper completion of work 10.01 acsr weasal conduclor!gl wire fixing of earthing rod as per respo manual and 11 as per direction of supevsing engineer induding the cost of labour eredtion and grouting of stay set including the work of nozing etc. as per respo manual and also 12.01 including the cost of arrangement of all grouting material, labour, t&p etc. required for proper completion of work 12.02 providing and fixing of stay insulator. providing s filling of 3x70!3x120 sq.mm. 11 ky 13 xlpe heat shninkable cable jointing kits outdoorllndoor type induding the cost of labour tsp carrier etc for proper completion of worl. safe camnage of transformer from store center or from any oilher place to the respective site of work through the kachha pacca road including the work 14 of its loading 8. unloading at the respective ends. including the work of dragging etc. and also including the cost of labour, tsp and earner etc. required for proper completion of work. ( distance 0 to 50 km.. , transformer , safe carriage of old line material viz. conductor, gi. earth wire, abc conductor, cross arm, mgle, channel, insulators, clamps 8 other line material 15 from any other place or from site o1 work to the work of its loading 8 unloading at the respedtive ends induding the cost of labour, t&p and carrier etc. required for proper completion of work. lnstallation of extra ton the old eredted poles wherever required alongwith all fifing as per direction of supervising engineer induding the cost of labour, t&p etc. required for proper 16 completion of work. the tpole shall be grouted with cement sand and brick ballastistone ballast in ratio 1:4:8 including the cost of arrangement of cement sand, brick ballastfstone ballast stone pad etc as per adtual site requirement. sate carnage oixlpe cable of size 3x7013x120 sq. 17 mmm. from store to respedve site of work including loading unloading at both ends. safe carmiage of xlpe cable of size 3x7013x120 sq. 17 mom. from store to respective site of work induding loading unloading at both ends. laying of 3m7013x120 sq.mm. 11 ky under ground cable after digging trench of 600 mm. wide, 1500 mm deep, providing the fine sand cushion beneath and above the cable. nhe cable shall be duly protected by lst dlass bricks, two on either side and third on top of the cable, laid in series 18 one after mhe other. the work includes supplying of fine sand and bricks, filling and ramming of the left out soil, closing the trench and levelling. spare cable shall be left and buried in hhe trench in the shape of rings at both ends. all material ( ercept cable ) , labour, t&p carner etc, required for proper completion of work will be arranged by me contradtor at his own cost 19 safe carriage or lt distribution box ( three p from store centre sarsol to pit site inclu ng loading and unloading at both ends mounbn nd fixing on pole also by making connections as per respo norms 20 providing and fixing of lt shackle insulator with nut & bolts as per respo norms. 21 demounting & carriage of site to store of following capacity transformer due to damage of pcc poles including the work of its loading & unloading, dragging etc. and also induding the cost of labour and t&p etc. required for proper completion of work. 21.01 25kvat / f 21.02 250 kvat / f re s agging of loose htilt line conductor as per 22 direction or superwising engineer it includes the cost of labour t&p carrier etc. required for proper completion of work. 22.01 acsrweasal condutor retighting of stay complete with nozelling & 23 binding including cost of labour t&p etc required for proper completion of work. 24 straightening or tiited pole at various places as per direction of je. giving connedtions to the genuine consmers by connedting cable thought installed lt distribution 25 box as per direction of supervising engineer it includes the cost of labour, t&p, carrier etc required for.proper. completion. 26 providing and fixing clamp with nur & bolts as per respo norms. 27 straightening or tilted double pole at various places as per direction of je body and neutral earthing o1400 kva transformer installed by digging of pit up to water level depth ( approx. 100 ) and then inserting 1 114 dia g.l. pipe of of ‘w grade, conforming to the requirement of is specdication and then connecting the top of 28 the inserted pipe and transformer bocfythrough cl strip of size 50x6 mm with the help of nut and bolt or through gas welding, as per diredtion of supevsing engineer induding the cost of arrangement of all materal, labourer, t&p, carrier etc. required for proper completion of work. construction of plinth of size 5x5x4’ above ground level and one ft. below the ground level of 9’. after excavation of 4 earth, bnick ballast shall be provided and rammering will be done properly after that a retaining wall of g’ width by first class brick in ratio 1:4 of cement and sand shall be made. the earth shall be filled up to one ft. below the top of the plinth. after this brick ballast shall be provided up to 6’ from the earth level and prop 29 rammering shall be done. one no. jall of 12 m mis. tor shall be fixed in the hollow of plinth a one ft. thick rcc in ratio of cement sand an stone ballast shall be laid on the top of the plintin the 12 mm thick plastering shall be done all around the plinth in 1:4 ratio of cement and sand. the contradtor shall be responsible to complete the work as per diredtion of supervising engineer lt including the cost of all material, labour t&p, carrier etc. required for proper completion of work , etc...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

20057433 tender for repair and maintenance=> 9 guarding of 11 k v line at road crossing by laying 3 nos. gl wire of size 6/10 swg parallel and fixing of lacings (tilli) at a distance at 1.5 mlrs as per direction of supervising engineer/respo mannual it. includes the cost of labour,t&p carrier etc. required lor proper completing of work. 10 resagging of loose and bad sag of l.t./h.t. line. 11 chopping of tree branches.. 12 tightening of stay 13 grouting of pcc/stp pole old 13.1 change of broken/damaged/missing following items : 14 disc insulator 15 nut & bolt off size 16 bended x arm/angle/channel 17 ailment of pcc/stp pole 18 stay clamps 19 d.p. clamp 20 stay insulator 21 making of plinth of the damaged/broken stp of the welded 03 nos. angle iron piece with the pole. 22 stay clamp. 23 stay insulator. 24 l.t. clamp. 25 l.t. shackle insulator. 26 l.t. insulator bolt 6 ench. 27 f clamp. 28 double pole clamp. 29 holding clamp. 30 bolt & nut off size. electrical works...

Government Engineering College - Uttar Pradesh

18485977 supply , installation and commissioning of surveying laboratory for civil department, 4 land measuring chain ( 30 meters / 100 ft ) having 150 links engineers / survey chain made of gl wire as per iss with bakelite handles and brass tallies. the handles are included in total length the chains should duly calibrated and standardized these have long life, due precision as the rings are precision machine cut and have no notches and cavities size 30 mtrs with standard pull long complete with 05 nos. arrow and waterproof synthetic fastening straps. 5 digital theodolite ( least cont 1” ) with dual side display and dual rechargeable battery, complete with aluminium telescopic tripod with improved quick clamp system and wing nut clamping. detailed specification as under : telescope : image : erect magnification : 30 x aperture : 45 mm focus distance : 1.35 m to ∞ stadia ratio / constant : 100 / 0 angle measuring system minimum reading : 1” or 5” precision : 2” ( 2 sec ) units :deg / mil / gon / v% display : dual, large character, backlit lcd tilt sensor automatic compensation : + / 3’ range ( user set on / off ) vials tubular : 30” / 2 mm circular : 8’ / 2mm plummet : optical / laser dust protection : ip – 54 operating temperature : 20°c to 50° ( 4° to 122° f ) 6 hand held gps capable of showing instant longitude & latitude. built in barometric altimeter & electronic compass battery operated : two aa size battery with 18 hours life typical. color display: 256 colour tft: 2.2 x 1.6 inch ( min ) receiver sensitivity: high accepts micro sd card ( min 2 gb included ) more than 100 plus user datums g sensor, e compass usb cable and software for usb & serial interface, computer cable ( if any ) , user manual & other accessory. carrying case waterproof casing ( ip x 7 ) complete with all accessories 7 micro optic theodolite erect image angle measurement accuracy 1” digital reading complete with all accessories...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

17113829 tender for construction of ht lune at naravanpur, susuwalii, varanasi to energise existing 100 kva tif under business plan 2018 19. earttiing of pole errechon of single sw and grouting with material mounting of fittings on errected stp laying and spreading of dog conuctor guarding of gl wire with lacing. cortage of stp. conductor. gi wire ana other mater grouting of stay providing of de centralised matenals cross arm clamp for 11 mtr stp ms n&b of size with washar...

Institute Of Engineering And Technology - Uttar Pradesh

14868079 purchase of electrical maintenance item switch , bell switch , socket , ceiling fan regulator 1.08 capacitor 109 plugs top 1.1 door bd 1.11 pvc tap rol steel grip 1.12 better hoier .13 bulb 1.14 led 1.21 pvc insulated 2 & 3 core copper wire pvc insuled 1.ssq mm single core 1100 v aluminium conductor pvc insulated single core 1100v alumuimim. conductor 13 pvc insulated 7ssq mm single core 11 oov fr copper conductor 1 31 pvc insulated isq mm single core i 100v fr copper conductor pvc insulated 1.ssq mm single core 1100v fr copper , iron clad main switch , change over switch 320 amp. 1.55 din type hrc fuse 250 link amp l&t 1.56 gl wire 1.57 ac sr conductor weasel 1.58 ac socket & top 1 59 surface i flush mounting 8 , 12 ways spn distribution board indoasian i .62 exhaust fan 1.64 led tube fitting 1.65 starter l& mica sheet , mcb , isolator digital energy meter , elcb , led tube , bulb etc...