Bharat Petroleum Corporation Limited - Uttar Pradesh

39820024 bids are invited for structural and painting work gi sheet , structure painting , tile work , boundary wall painting , plaster , pipeline painting , slogan writing , fire water line painting total quantity : 19800...

Ministry Of Petroleum And Natural Gas - Uttar Pradesh

38084048 bids are invited for services for miscellaneous painting job 1 pl b scrap wo scaf for lpg pipeline 1127.60 m2 2 zn phosphate wo scaf for lpg 1127.60 m2 3 pl finish pu 2c for lpg pipeline 1127.60 m2 4 pl b scrap wo scaf manual, primer painting gate valve 12 lpg pump house 8.00 ls 5 gate valve 10 6.00 ls 6 gate valve 8 16.00 ls 7 gate valve 6 29.00 ls 8 gate valve 4 48.00 ls 9 gate valve 3 41.00 ls 10 gate valve 2 44.00 ls 11 gate valve 1 15.00 ls 12 air vessel 7.00 ls 13 evacuation unit 2.00 ls 14 lpg pump 6.00 ls 15 lpg compressor 3.00 ls 16 12mm thick with 1:5 ( 1 cement: 2 parts of fine sand: 3 parts of coarse sand ) 500 m2 17 pasting of plaster of paris / putty for uniform finish 1000 m2 18 2 coats of plastic emulsion paint conforming to is 5411. 5000 m2 19 2 coats of synthetic enamel paint with one coat of primer for gates, crossovers & equipment’s 5000 m2 20 boundary wall painting 2 coats of oil bound distemper 9000 m2 21 admin buidling painting interior 2 coats of plastic emulsion paint conforming to is 5411. 900 m2 22 admin building painting exterior 2 coats of plastic emulsion paint conforming to is 5411. 1100 m2 23 planning building painting interior 2 coats of plastic emulsion paint conforming to is 5411. 250 m2 24 painting of drive unit& gear assembly two coats of good quality of enamel paint of 30 microns per coat 150.00 ls 25 dv room, fire water line pedestals, shed plinths 2 coats of oil bound disptemper 4200.00 m2 26 main gate, gate 2 & emergency gates 2 coats of plastic emulsion paint conforming to is 5411 120.00 m2 27 painting of double hydrant points including hydrant box 2 coats of pu aluminium paint at 30 microns per coat 300.00 m2 28 painting of chain conveyors 2 coats of synthetic enamel paint with one coat of primer 2500.00 m2...

Indian Oil Corporation Limited - Uttar Pradesh

28295435 maintenance and servicing of fire fighting equipments and systems in bkpl , group b bkpl allahabad pump station , checking , inspection , servicing and maintenance of fire fighting system , equipments hydrants , extinguishers of all type ( dcp/co2/clean agent ) , water monitor up to the mark as per oisd/isi standards to provide & best functioning of the equipments always in best healthy condition inclusive of periodically cleaning , checking /inspection/oiling/ greasing of assemblies such as coupling , nozzles , valves , hydrants , extinguishers , hose pipes , water monitor , compounds drums , nozzles foam bunch , hose boxes , sand buckets etc , updating the data & identification tags , recording the status of checking in history register etc . as directed by the engineers in charge with all labors , carriages , materials etc . complete inclusive of all taxes . ( inspection and servicing of the equipment/fire fighting facilities is to be done periodically as mentioned against each ) : , fire hydrants ( double headed ) on monthly basis , fire extinguishers of all types & capacities on monthly basis , hose boxes monthly basis , valves of fire line of all sizes including contractor supplied grease of suitable quality on monthly basis . , foam /water monitors on monthly basis/mefg , sand buckets with stands with all bucket on monthly basis , taking delivery and refilling the extinguishers of various sizes /capabilities including supply of dry chemical powder , co2 gas etc updating the data & identification tags , recording the status of checking in history register etc as per isi standard and replacing the same as directed by engineer in charge . ( the co2 cylinder may to be taken out and delivered back within 10 days after re filling /repairing . however fire extinguishers co2 are to be supplied /kept temporary in place of each fire extinguisher for which taking out for re filling /repairing is required ) . , dry chemical powder , 0 . 2 kg dcp cartridge , 2 kg co2 cylinder , 6 . 8 kg co2 cylinder , 2kg clean agent cylinder , supply and replacing the spares /assembles etc of the fire fighting equipments system for all sizes / capacities as per isi standard and approved make with all labours , materials , carriages , inclusive of all taxes etc . complete , supply and installation of clear pvc , spiral wound hose ( pick up tube ) of length 3 m length and dia 40 mm with ss jublee clamp for tightningsuitable for existing connectors of 750 gpm monitor , hydrants sheet washer/rubber including fitting at site . , hydrants coupling washer , rubber washer for extinguisher , co2 safety valves 155kgf/cm2 , co2 safety pins , isi marked discharge pipe with horn for 2kg , 3 . 2kg , 4 . 5kg co2extinguishers , isi marked discharge pipe with horn for 6 . 5 kg and 6 . 8kg co2 exitinguishers . , rubber gasket of dcp main cap , hose plunger set & nut . , hose spring & nut , dcp main cap ( gun metal ) cp , dcp plunger pin with spring , dcp plunger top , squeezing grip ( plastic ) nozzle , replacement of fire hose box glass ( fron , dcp cylinder discharge pipe of sufficient length for 10/9 kg capacity fire extinguisher , dcp cylinder discharge pipe of sufficient length for 75/70 kg capacity fire extinguisher , supply and fitting of plastic blank cap ( as per is 5290 , red colourwith gi chain ) suitable for 63 mm hydrant outlet as per direction of eic , supply and painting with two coats synthetic enamel paint ( asian/burger ) fire paint including scrapping , cleaning , applying one coat of red oxide primer cost of all labours , materials , carriage , taxes , letter/number writing , identification marks etc . complete in all respect . , brush painting of fire hose boxes ( inside and out side ) including stand with two coat of paint including letter/number writing ( colour to be specified by eic ) , spray/brush painting of fire bucket stand with its buckets ( 4 6 bucket set ) including letter/number writing . , spray painiting of fire extinguishers of all sizes including letter/number writing . , spray/ brush painting of foam/water monitors/double hydrant valves along with its stand post including letter/number writing . , fire siren including letter / number writing . , others , ppe maintenance / up keeping / cleaning on monthly basis of various items like helmets , breathing apparatus , water jel blanket , asbestos blanket , hand gloves ( rubber / asbestos ) , first aid box , stretcher , resuscicator , safety belt , ear muffs , fire proximity suits , safety torch , safety goggles including the cost of labour , material etc . complete as per instruction of engineer in charge . , cleaning & stacking properly the foam containers , updating stock , date of expiry , date of manufacturing on board and in register , placing foam containers at the foam monitors and water hydrants . , taking hose pipe for hydrotesting and keeping it back in positionafter drying /rolling inclusive of all taxes . , air filling in cylinders of breathing apparatus inclusive of all cost with transportation . , hydraulic testing of co2 cylinders inclusive of all taxes ( 2 to 4 . 5 kg/cm2 ) , hydraulic testing of co2 cylinders inclusive of all taxes ( 6 . 8 kg/cm2 ) , hydraulic testing of dcp cylinders of all sizes inclusive of all taxes , hydraulic testing of breathing appratus set , supply & pasting of slips on the extinguishers showing how to use the extinguishers & date wise maintenance records of fire extingusher . the good quality of adehsive to be used on slips for sticking on the extinguishers inclusive of all taxes as per direction of engineer in charge . , supply and fixing of wind socks on the position including all labour , tolls and tackels as per direction of engineer in charge inclusive of all . , patch work welding on the firefighting/foam line in case of leakage including all manpower & materials with tools and tackels with materials required as per satisfaction of the engieer in charge upto 12x12 size inclusive of all . , first aid box with snake serum , fire bucket , safety helmet , lettering with black japan paint , supply & fitting of transparent acrylic sheet thickness 3 mm of hose box inclusive of rubber beeding by fixing it with proper adhesive wherever required complete in all respect inclusive of material , lab ours , consumables etc . ( inclusive of rates for both glasses and rubber beading . , complete overhauling of hand operated siren including oiling , greasing , painting and testing as per direction of eic inclusive of all tools & tackles , transportation , man power etc , testing of afff as per bis:4989 from reputed institutes like girda or any other approved laboratory in all respect by providing cas , transportation , man power etc . , maintenance and calibration of multigas detector sensor ( lel , o2 , co , h2s ) the charges includes cost of calibrating canisters inspection , maintenence of the detectors and issuance of the calibration certificates the cost of sending lel meterto the party workshop ( in india ) will be in the scope of iocl but after calibraiton and completion of work thecost of transportation of lel meter to iocl installation shall be in thescope of vendor . rate are for calibration of all sensor , make: crowcon , uk , model gas pro , make: m/s respo products , model: qrae ii , make: bw ( honeywell ) , model: gasalertmax , fire water line , dismantling of gate valves of sizes up to 8 of fire hydrant line e etc from bonnet cleaning and lapping the gate and refixing it with new gasket ( iocl supplied ) alongwith all tools , tackles , material , manpower etc , removal or installation of of faulty gate valves/nrv/glove valve/strainer upto 8 inch size including transportation either from owners storage point to workshop or work site including tools tackles , labour , etc as per direc...

Indian Oil Corporation Limited - Uttar Pradesh

25630257 annual maintenance contract for fire fighting and safety equipments checking, servicing, upkeep and associated works at indane bottling plant, lucknow 1 checking of fire engines to ensure adequate pressure with no leakage and mainting record on daily basis and keep fire fighting system on auto all the time. 2 safety checking of packed / bulk tts fittings & safety equipments e.g. fire ex, spark arrestor etc and record keeping also to ensure display of tt / truck no and date of testing on equipments. 3 greasing of suction and discharge valves ( fire pumps & jockey pump ) and record keeping. 4 recirculation / flushing of hydrant line as per plan. 5 greasing of all isolation valves of monitors, hydrants and all other valves on water line and record keeping. 6 greasing of all isolation valves on lpg liquid and vapour line and record keeping. 7 checking, repairing of all rovs of plant and record keeping. checking and maintenance to be done as per maint task list. 8 oiling, greasing and maintenance of all hand sirens at plant and record keeping. 9 testing, checking and recharging ( dcp ) of all fire extinguishers at plant ( 10 kg dcp, 75 kg dcp, 2.0 kg co2, 4.5 kg co2 & 6.5 kg co2 ) and maintaining record. visual checking monthly and internal checking to be done bi monthly 10 operation of sprinkler, checking & flushing of its airline, cleaning of sprinkler nozzle etc and record keeping. 11 assistance during safety training & fire drill and maintaining record. 12 cleaning and upkeep of ppes including all fire fighting and safety equipments for its smooth operation and keeping its record. 13 cleaning of all suction strainers ( fire pumps & jockey pumps ) including cooling water line strainer. 14 cleaning of all deluge valve strainers ( 23 nos ) including two strainer before rcv on water and air line and record keeping 15 testing / calibration / replacement of all rrl hose at plant and store and record keeping. 16 testing / calibration / replacement of all pressure gauge at plant and record keeping. 17 testing of all lpg hose at plant and record keeping. 18 maintaining frequency of operation of jockey ( not less than 30 min ) and arresting any leakage on fire water line, daily checking as per checklist. 19 checking, upkeep and maintenance of all hydrant, monitors and hose boxes and repair as required to ensure no water leakage in fire water / sprinkler network. 20 maintaining frequency of operation of security air compressor ( not less than 30 min ) and arresting any leakage on air line / joints and daily checking as per checklist.. 21 checking of hla interlocking with rov and record keeping 22 monthly update of inventory of fire fighting and safety equipment at store with updation in bin card as and when used and submission of monthly report. 23 monthly checking of gms sensors by leaking lpg in individual sensors and record keeping. 24 monthly checking of bullet area including all gauges reading, instruments and water accumulation in bullet tunnel and top nozzle and record keeping. 25 checking and ensuring lock and seal of srv, pavs and all valves at fire water line and water tank and record keeping. 26 daily checking of tube well and maintaining water level in fire water tank and record keeping. 27 daily checking of tld bay, ph, imparting safety instruction / training and upkeep of tld ph area and record keeping. 28 ensuring assistance during water draining from bullet and cleaning with water after draining and record keeping. 29 display and maintaining of all dates of testing , checking, sr no etc and changing after rechecking and re testing and record keeping. 30 daily checking and repairing of fire water pumps of fire engines and jockey including arresting gland leak & greasing of bearings and record keeping. 31 maintenance of sand buckets / scoops and storage and top up sand as and when required. 32 regular checking and upkeep of safety trolley will all equipments. 33 maintaing road accident kit as per oisd list and providing assistance during rescue of road accident. 34 checking of ilsd and mcp as per oisd 144 and record keeping. 35 assistance during amc visit by external parties. 36 cleaning of all vapour traps of plant and maintaining of water seal. 37 maintaining and upkeep of canteen cylinder bank and connecting lpg pipe and hoses and regulator for safe operation....

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

22715388 supply of pumps spares obra tps 1 russian make fire pump ( as per sample ) ( enter zero vlaue for this row ) 2 complete rotating assy. of fire pump dynamically balanced with 3000 rpm consist of shaft 1 no., sleeve 02 nos., impeller 01 no., diffuser 02 nos., water defelector 02 nos., gland bush 02 nos., lantern ring 02 nos. ( shaft ss, sleeve, l ring aluminum 3 bearing housing ( mat grey ci ) 4 coupling set with coupling bolt with nut & bush ( mat en 24 ) 5 coupling bolt with nut & bush ( mat en 24 ) 6 impeller ( mat grey ci ) 7 indian make spares of fire pump ( as per sample ) ( enter zero vlaue for this row ) 8 lagging ring ( mat ss ) 9 neck ring ( mat ss ) 10 ‘o ’ring rubber ( neoprene rubber ) 11 oil seal rubber ( neoprene rubber ) 12 gland bush ( mat ci ) 13 spares of raw water pump ( dsm 4m ) ( as per sample ) ( enter zero vlaue for this row ) 14 pump shaft ( mat ss ) 15 casing wear ring ( mat ss ) 16 cartridge for bearing ( mat ss ) 17 impeller ( 1 set= 2 nos. ) mat grey ci ) 18 eye bolt for gland bush ( mat en 24 ) 19 shaft sleeve de / nde ( mat ss ) 20 coupling bolt with nut & rubber bush. 21 spares of raw water pump ( dsm5b ) ( as per sample ) ( enter zero vlaue for this row ) 22 pump shaft with key & nut ( mat ss ) 23 impeller ( 1 set= 2 nos. ) mat grey c.i. 24 casing wear ring ( de / nde ) mat brass 25 cartridge for bearing ( de / nde ) mat brass 26 inter stage diaphragm ( mat ss ) 27 gland bush ( mat ss ) 28 lantern ring ( mat grey c.i. ) 29 shaft sleeve ( de / nde ) mat ss ) 30 shaft sleeve ( de / nde ) ( mat ss ) , ( de 2 nos., and nde 02 nos. ) 31 inter tae diaphragm 32 lantern ring ( mat grey ci ) 33 spares for filter water pump ( 4up 2x30 ) ( as per sample ) ( enter zero vlaue for this row ) 34 pump shaft ( mat ss ) 35 casing wear ring ( de / nde ) mat ss ) 36 cartridge for bearing ( de / nde ) mat brass 37 bearing cover ( de / nde ) ( mat ss ) 38 shaft sleeve ( de ) ( mat ss ) 39 shaft sleeve ( nde ) ( mat ss ) 40 gland bush ( mat brass ) 41 lantern ring ( mat ss ) 42 coupling pacer ( mat ss ) 43 shaft sleeve nut ( de / nde ) ( mat ss ) 44 emulsifier system: ( as per sample ) ( enter zero vlaue for this row ) 45 ½” check valve on compressed air line, pressure 6 kg / c ( g.i. ) 46 neoprene rubber gasket for air kit of front cover of deluge valve of size: 6” valve 47 neoprene rubber gasket for air kit of front cover of deluge valve of size: 4“ valve 48 sprinkler 114 degree projector ( brass ) 49 sprinkler 90 degree projector 50 nipple l=100mm ( g.i. ) of following size: ( enter zero vlaue for this row ) 51 ½” 52 ¾” 53 1” 54 socket ( g.i. ) of following size: ( enter zero vlaue for this row ) 55 ½” 56 ¾” 57 1” 58 tee ( g.i. ) of size following size: ( enter zero vlaue for this row ) 59 ½” 60 ¾” 61 1” 62 allen screw of size 6mx16mm ( s.s. ) 63 c.s. head screw of line 6mx20mm ( brass ) 64 6nks 10 sump pump ( as per sample ) ( enter zero vlaue for this row ) 65 head shaft with key and chuck nut ( s.s. ) 66 impeller shaft ( s.s. ) 67 impeller ( c.i. ) 68 impeller nut, m 30 ( g.m. ) 69 impeller shaft sleeve for shaft ( de ) ( brass ) 70 coupling bolt with nut & teflon bush ( s.s. ) 71 housing bush ( brass ) 72 diesel engine fire pump shaft with key & locknut 73 2nks 10 sump pump ( as per sample ) ( enter zero vlaue for this row ) 74 head shaft ( s.s. ) 75 inter mediate shaft ( s.s. ) 76 impeller ( c.i. ) 77 impeller shaft sleeve for shaft ( brass ) 78 intermediate housing bush ( brass ) 79 coupling bolt with nut & bush ( s.s. ) 80 temporary sump pump: ( as per sample ) ( enter zero vlaue for this row ) 81 rubber gasket of size f 225mm, t=6mm 82 rubber gasket of size f 165mm, t=4mm 83 impeller ( c.i. ) 84 coupling bolt with nut & bush ( c.s. ) 85 pump shaft ( s.s. ) 86 brass spindle with bush for fire water line valves ? 150 mm ( brass ) n...