Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

34107682 patrolling and maintenance work at various lines under etd lakhimpur 1 patrolling of 132kvtransmission line, tower to tower from one end to other end and submission of quatery patrolling reportwithin seven daysafter completion of each patrolling in triplicate in prescribed proforma mentioning stolen / missing tower parts & tower accessories such as missing danger / phase / number plate. tree / tree branches & bamboo koty falling in line conridor, damage to earth wire. conductor, jumpers, insolalors & other line accosories, damage to foundation. coping, chimney earthingetc. with the help of patrolling teams. 2 132kv gola nighasan line ( length of 83 km ) ( newly constructed ) 3 132kv lakhimpur khambarkhera sugar mill line ( length of 15 km ) 4 lilo of 132kv lakhimpur lakhimpur line@oyel ( length of 7 km ) ( newly constructed ) 5 lilo of 132kv shahjahanpur gola @ gola ( 220 ) ( length of 7 km ) ( newly constructed ) 6 emergency patrolling of 132 kv transmission line byexperienced persons in case of any tripping / breakdown of line. the emergency patrolling inclues checking of towers, conductor, earth wire, insulator, clamps, fitting etc to locate the defect / fault / deficiencies. the energency patroliing shall be done on the basis of as and whenn required. the work of emergency patrolling has to be started immediately after receiving the call of sdo / je. 7 cleaning of corridor in03 monthby lopping / chopping of various species of tree branches and cutting of bamboo bushes falling under the corridor with all due care of safety and precaution to avoid any damage to near by building.crop & power telephone lines passing near vicinity of the trees of 132kv transmission line along with throeing of cut branches at least 27 meter away from the line corridor. 8 fixing of tower members nuts bolts etc. as directed by sdo / je concerned, punching of bolts by champering, fabrication, cartage etc. meloding opening / cutting of nuts bolts of remaining cut pieces of tower member thetted by miscreants to be opened / cut safly with the help of gas cutter / hackshaw blade. including all required labour. t&p vchicle etc. required for completion of above work. 9 attending breakdown due to failure of disc insulator and replacement of tension / suspension string alongwith mobilization of skilled gang including carriage of material from store to site and site to store for completion of work. 10 suspension string ( 70kn disc insulator ) 11 checking & tighting of jumpers 12 cleaning of pocelain insulators ( only in polluted area ) once in in year. 13 attending breakdown earthwiresnapping of 7 / 10 swg earthwire following works are to be carried out. 14 dismantling opening of earthwire of one span of size 7 / 10 swg includinge / w accessories, etc, lowering earthwire between location with suspension clamps, coppwer bonds clipping etc. rerolling of dismantledearthwire on drum and shifting fromto designated store. 15 laying, tensioning, stringing, clamping, jointing etc of earthwire including fitting of all e / w accessories, etc.including shifting earthwire from store tosite...

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

33900756 work of 132 kv modipuram sardhana line & 132 kv modipuram kankarkhera ii line on common towers due to infringement in ncrtc corridor near 220 kv substation modipuram under etd ii meerut. 2 towers and nut & bolts 3 fabrication, galvanising, inspection & supply ofmc tower including stubs, extensions & stub setting template, as per drawing & bom.ms material. ( k rao design ) 4 fabrication, galvanising, inspection & supply ofmc tower including stubs, extensions & stub setting template, as per drawing & bom. ht material. ( k rao design ) 5 fabrication, galvanising, inspection & supply ofdc tower including stubs, extensions & stub setting template, as per drawing & bom. ( kptl design towers ) 6 hot dip galvanised nuts & bolts for mc & dc type towers 7 tower accessories 8 number plate 9 danger plate 10 phase plate 11 pipe type earthing material for towers 12 hardware suitable for acsr zebra 13 singletension fitting 14 double tension fitting 15 vibration damper 16 repair sleeves 17 mid span compression joint 18 220 kv 160 kn polymer insulator 19 hardware suitable for acsr panther 20 singletension fitting 21 double tension fitting 22 vibration damper 23 repair sleeves 24 mid span compression joint 25 132 kv 120 kn polymer insulator 26 hardware suitable for earthwire 27 tension clamp for 7 / 10 swg earthwire 28 vibration damper for 7 / 10 swg earthwire 29 mid span compresion joint for 7 / 10 swg earthwire 30 tension clamp for 7 / 9 swg earthwire 31 vibration damper for 7 / 9 swg earthwire 32 mid span compresion joint for 7 / 9 swg earthwire 33 work 34 survey including prepration of profile & schedule of materials, marking of locations ( route length ) 35 check survey & final peg marking. ( route length ) 36 cost of excavation of tower foundation pits including all earth work, back filling watering and leveling. ( kptl design towers ) 37 cost of excavation of tower foundation pits including all earth work, back filling watering and leveling. the work has to be done manually. ( k rao design ) 38 setting of stubs including all foundation work but excluding cost of concreting and excavation ( rate per location ) for following m / c and dc towers: 39 md+0 40 mc+0 41 db+5 42 dc+5 43 cost of concreting for all types of m / c / conventionaltower foundation including cost of cement core sand, stone grid, dewatering, shoring and shuttering, forming, curing but excluding cost of reinforcement bars with 1:2:4 mix concrete ( rcc ) . 44 installation of steel reinforcement bars in rcc foundation including cost of cutting, welding, binding and placing them in foundation pits. 45 erection of super structure of mc / dc towers and their extensions including all works above ground level and fitting of danger , number & phase plate, bird guard etc but excluding hoisting of insulator, hardware & accessories. 46 tack wedling of all the bolts up to the height of one section or 5 mtr. from ground level whichever is higher with three tacks of 10mm / 12mm elctro;; / de & application of zinc rich point on the affected surface including cost of materials. 47 carriage of new material such as conductor, hardwares, tower parts etc from store to site. 48 laying , stringing, tensioning clamping, jointing etc of acsr panther conductor including hoisting of insulator, fitting of all necessary hardware and accessoriesi.e. fittings armour rods, vibration dampers etfc. on all six pahses of 132 kv dc lines. 49 laying & stringing of 7 / 10 swg eartwire including fixing of all type of hardware fittings on 132 kv lines. 50 laying , stringing, tensioning clamping, jointing etc of acsr zebra conductor including hoisting of insulator, fitting of all necessary hardware and accessoriesi.e. fittings armour rods, vibration dampers etfc. on all three pahses of 220 kv s / c lines. 51 laying & stringing of 7 / 9 swg eartwire including fixing of all type of hardware fittings on 220 kv lines. 52 destringing of acsr panther conductor wherever required.the work includes all stringing work required for proper comopletion of work. all the six conductors 53 destringing of ground wire including of all accessories making proper bundle of earthwire including safe carriage of all material from site to store. 54 dismantalling of existing foundation in all respect. 55 dismantalling of 132 kv towers. 56 dismantalling of monopole. 57 pre insattaltion of assembly of ers structure at 400kv s / s greater noida by tightening of joints, nuts & bolts, installtion of guy wires, making holes for anchor installer complete in all respect. 58 installtion of ers structuree., fixing of guy wires & other accessories & hardwares. hoisting of insulators complete in all respect. 59 stringing of all the three acsr panther conductor alongwith hw fitting by making cutpoint at ers tower & stringing between ers & towers for both ends of ers 60 arrangement of watch & ward round the clock with atleast 04 nos. security guards, security at ers location and also at the time of dimantalling of ers conductor & hardware with hardware fittings. 61 de stringingof all the three acsr panther conductor alongwith hw fitting for removal of ers. 62 dismantalling of ers structuree., removal of guy wires & other accessories & hardwares. dehoistingof insulators complete in all respect. 63 safe transportation including loading, unloading of ers structure alongwith accessories, guy wires etc from the store at 400kv s / s greater noida to site near modipuram & vice versa. ( approx distance=100 km ) ...

Uttar Pradesh Power Corporation Limited - Uttar Pradesh

33361713 misc civil work at shakti bhawan (hq) lucknow sl. no. item description 1 laying and jointing pvc pipe. heading 2 cement concrete with 2cm gauge approved hard stone ballast,coarse sand (f.m. 1.8 to 2.5) and cement in proportion of 4:2:1including supply of all materials, labour,side shuttering ifrequired and t&p etc. required for proper completion of work. 3 first class brick work in 1:6 cement and coarse sandf.m.1.8 to 2.5) mortar in s.s.including supply of all materials, labour & t&p etc. required for proper completion of work. 4 12 mm thick plaster with cement mortar consisting of one part of cement & six part of coarse sand (1:6), minimum thickness not to be less then 10 mm including supply of all material, labour and t&p etc for proper completion of work. 5 supply and laying 8 mm thickglazed floor tiles of somany, johnson or equivalent make, of size 300x300 mm, laid with1:3 cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supplyof all materials, labour and t&p etc. completion required for proper completion of the work. 6 supply and laying 6 mm thickglazed tiles of size 300x450 mm in skirting / dado laid with1:3 cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete,including supplyof all materials, labour and t&p etc. completion required for proper completion of the work. 7 providing and laying floor of 8 mm thick vitrifiedtiles in flooring or skirting of approved brand (bell, johnson or equi. make)size of 600x600 mmof approved shade, colour and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cementmixed with pigment to match the shade of tile including cost of all material, labour and t&p required for proper completion of the work. 8 providing and laying of 16 mm thick granite ( black/ brown) inflooring or skirting ,of approved shade, colour,size and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cementmixed with pigment to match the shade of granite floor including cost of all material, labour and t&p required for proper completion of the work, as per direction of engineer incharge. 9 painting or varnishing new iron work in small areas or new woodwork with one coat of ready mixed priming paint and one coat ofapproved superior quality ready mix paint luxol or equivalentbrand or varnish including supply of all materials, labour and t&p etc. required for proper completion of the work. paint to be used should conform to the i.s. 103 1950. 10 as in item 02 above but for every coat after first coat. 11 applying birla putty or equivalent putty on previousaly bila putty smoothen surface over one cost of water base cement primer of ici or equivalent brand for smoothining and leveling of the surface as per requirement and direction of e/i including cost of all material , labour and t&p required for proper completion of work. 12 paintingwith one coat of acrylic emulsion paint of berger/ asian/ ici or equivalent paint on previously painted surface. including all labour, material and t&p etc required for proper completion of the work, ( preparation of base with birla putty etc. and a coating of primer shall be paid extra) . 13 same as above in item no 14 but for every coat after first coat of acrylic emulsion paint of berger/ asian/ ici or equivalent paint. 14 dismantling brick work or stone work in lime or cement mortar andincluding stacking of materials as directed by theengineer in charge within a distance of 60 metres. 15 dismantling for floors to be stone flagged or tiled floor.including base concrete and including stacking of dismantledmaterials as directed by the engineer in charge within a distanceof 60 metres. 16 dismantling existing plaster including disposal of refuse as directed by the engineer i/c with in a distance of 60 m. 17 scrapping old white or colour wash or distemper including disposal of refuseas directed by the engineer i/c within a distance of 60 m. 18 renewing panes of 4 mm glass including supply of glass with putty and brads including supply of all materials, labour and t&p etc. required for proper completion of the work. 19 disposal of rubbish / debris out side the uppcl area as per direction of er/in charge including cartage, labour and materials, t&p etc. required for proper completion of the work. (no. deduction for voids shall be made). 20 providing and fixing sun film of gareware or equivalent make onglass panes of door and window shutters including cost of allmaterials,labour and t&p etc. required for proper completion ofthe work. 21 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. concealed work, including cutting chases and making good the walls etc. 22 20 mm dia nominal bore outer dia pipe 23 20 mm dia nominal bore outer dia pipe 24 providing and fixing full way20 mm dia g.m. gate valvewith wheel, isi mark heavy quality including supply of all materials, labour and t&p required for proper completion of work. 25 making water connection of pipe line with mains ( 25 mm to 100 mm ) dia. by providing and fixing ferrule (25 mm dia) gi union and nipple including cutting and threading the pipe, inspection, testing, cutting and making good the road, executing bond with nagar maha palika, fixing of pipe line upto the points near the building complete work including supply of all materials, labour and t&p etc. required for proper completion of work.. 26 providing and fixing 600 mm x 450 mm beveled edge mirror of atul,kiran makeglass with indian polish 6.50 mm thick complete with back of 600 mm x 450 mm x 6 mm hard board sheet fixed to wooden cieats with c.p. brass screws and washers including supply of all materials, labour and t&p etc.required for proper completion of the work. 27 providing and fixing 750 mm x 20 mm size c.p. brass towel rail of approved qualityincluding bracketsincluding supply of all materials,labour and t&p etc. required for proper completion of the work and cutting and making good the wall plaster etc. required for work. 28 supply and fixing 100 mm pvc nahani trap india make of heavy approved quality complete with ci grating,includingsupply of all materials,labour and t&p etc. required for proper completion of the work. 29 providing and fixing ci grating 100 mm dia includingall materials, labour cartage t&p etc.required for proper completion of the work. 30 providing and laying , pvc ( finolex orquivalent ) pipe excluding cost of excavation, c.c. etc including its jointing and connection, allmaterials, labour and t&p etc. required for proper completion of the work 110 mm dia. 31 providing and fixing 110 mm dia swr, pvc ( finolex or equivalent ) bends including cost of all materials, labour and t&p etcrequired for proper completion of the work. 32 providing and fixing 110 mm dia swr, pvc ( finolex or equivalent )trap including cost of all materials, labour and t&p etcrequired for proper completion of the work. 33 providing and fixing 110 mm dia swr, pvc ( finolex or equivalent )socket including cost of all materials, labour and t&p etcrequired for proper completion of the work. 34 providing and fixing 110 m m dia swr, pvc ( finolex or equivalent ) plain teeincluding cost of all materials, labour and t&p etcrequired for proper completion of the work. 35 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. this layer will be allowed to air cure for 4 hours. (b) second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 36 providing and fixing false ceiling at all heights with integral densifiedr armstrong false ceiling tiles of size 595x595 x12 mm of approved texture, design and patterns having nrc (noise reduction coefficient) of 0.50 (minimum) as per is 8225:1987, light reflectance of 85% (minimum). non combustible as per bs:476 (part 4), fire performance as perbs:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 w/m k as per astm 518:1991, in true horizontal level suspended on interlocking metal powder coated t grid of hot dipped galvanised iron section of 0.40 mm thick on silhouette profile,rotary stiched double webbed white with 6 sub head : 26 new technologies and materials 1632 mm reveal profilewhite/black),comprising of main t runners of size 15x42 mm of length 3000 mm, cross t of size 15x42 mm of length 1200 mm and secondary intermediate cross t of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter m 6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and l shape level adjuster of size 85x25x2 mm. galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall s.s screws. the work shall be carried out as per specifications, drawing and as per directions of the engineer in charge. 26.23.1 with 12 mm thick armstrong miniralfobre sound absorbing sheet including cost of all materials,labour and t&p etc. required for proper completion of the work. 37 supply and fixing of jet spray model no ahs 1557 of jaquar make as approved by e/i. the work includes cost of all labour, material t&p for proper completion of work . 38 providing and fixing soap dishpence model no can 1137njaquar make or equivalent including supply of all materials,labour and t&p etc.required for proper completion of the work. 39 supply and fixing of of waste coupling of make model no ald 705l130of jaquar make or equivalent. make as approved by e/i. the work includes cost of all labour, material t&p for proper completion of work 40 supply and fixing ofhealth faucet model no ald chr 565 with 1.00 mtr long flexible tube in chrome finish and wall hookof jaquar make or equivalent. make as approved by e/i. the work includes cost of all labour, material t&p for proper completion of work 41 supply and fixing of extended wall hung model cns wht 353s with cistren model cns wht 203of jaguar make or equivalent. make as approved by e/i. the work includes cost of all labour, material t&p for proper completion of work 42 supply and fixing of wash basin model no fns wht 40801size 600x470x160 padestal model no fns wht 40301 of jaquar make as approved by e/i. the work includes cost of all labour, material t&p for proper completion of work 43 supply and fixing of two way bib cock with wall flange model noopp 15041pm of jaquar make or equivalent. make as approved by e/i. the work includes cost of all labour, material t&p for proper completion of work 44 supply and fixing of basin trap with regular swinging spout(wall mounted model) withmodel no flr chr 5347n of jaquar make or equivalent. make as approved by e/i. the work includes cost of all labour, material t&p for proper completion of work 45 supply and fixing of angular stop cock with wall flange model no opp 15053pmof jaquar make or equivalent. make as approved by e/i. the work includes cost of all labour, material t&p for proper completion of work 46 providing & fixing oflamination both side on flush door complete with all fittings(excluding cost of door lock & door closure), etc all complete all complete as per drawing, specification and direction of engineer incharge. 47 wiring point for light with 1.5 sq. mm.frlsh pvc insulated multistrand single core copper conductor cable but in pvc conduit with 1.5 sq. mm.frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduit with modular type switch in place of piano type switch. . 48 wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm. frlsh pvc insulated multistrand single core copper conductor cable in in pvc conduit with 1.5 sq. mm.frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduitwith modular type switch in place of piano type switch . 49 wiring point for plug with 1.5 sq. mm.frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit with 1.5 sq. mm.frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduit plug point with modular switch & socket in place of piano type switch & socket. 50 supply and fixing of havels make or equivalint heavey duty exaust fanas per direction of engineer in charge required for proper completion of the work. 51 cement concrete with 2cm gauge approved hard stone ballast,coarse sand (f.m. 1.8 to 2.5) and cement in proportion of 4:2:1including supply of all materials, labour,side shuttering ifrequired and t&p etc. required for proper completion of work. 52 first class brick work in 1:6 cement and coarse sandf.m.1.8 to 2.5) mortar in s.s.including supply of all materials, labour & t&p etc. required for proper completion of work. 53 12 mm thick plaster with cement mortar consisting of one part of cement & six part of coarse sand (1:6), minimum thickness not to be less then 10 mm including supply of all material, labour and t&p etc for proper completion of work. 54 dismentaling 2 nos old ci pipe ncluding cost of scafolding, all labor material, t&p etc required for proper completion of the work. 55 providing and fixing of supreme make or equivalent make 160 mm dia pvc pipe of 6 kg pressure for ground floor to 07th floor vertically in duct/wallincluding cost of tee, bend,clamp, scafolding, all labor material, t&p etc required for proper completion of the work. 56 providing and fixing 32 mm dia nominal bore outer dia pipe chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. concealed work, including cutting chases and making good the walls etc. 57 making water connection of pipe line with mains ( 25 mm to 100 mm ) dia. by providing and fixing ferrule (25 mm dia) gi union and nipple including cutting and threading the pipe, inspection, testing, cutting and making good the road, executing bond with nagar maha palika, fixing of pipe line upto the points near the building complete work including supply of all materials, labour and t&p etc. required for proper completion of work. ...

Telecommunications Consultants India Limited - Uttar Pradesh

33251261 selection of partner for design, engineering, manufacturing, testing, supply, stringing, installation, testing & commissioning etc. of opgw alongwith hardwares & accessories, termination at both end substations, including replacement of existing earthwire & related works of 220 kv & 132kv different existing transmission lines ( approx. 6636 route kms ) of upptcl, on turn key basis....

Uttar Pradesh Housing And Development Board - Uttar Pradesh

33212055 bids are invited for electrification work at dr. shayama prasad mukharjee (civil) hospital, hazratganj, lucknow 1 wiring point for light with 1.5 sq. mm.frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit on surface with 1.5 sq. mm.frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduit. [uppwd sor : 2018, 121 (c) + 187 (a)] 2 supply and fixing of power plug with 20 amp./250 volt flush type modular switch and 5 pin 20 a/250 volt flush type universal modular socket switch on concealed m.s box including supply of all material, labour t&p etc. required for proper completion of work. [uppwd sor : 1139 (a)] 3 wiring point for plug with 1.5 sq. mm.frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit on surface with 1.5 sq. mm.frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduit. [uppwd sor : 2018, 124 (c) + 187 (c)] 4 supply and wiring of submain with two number 2.5 sq.mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 20mm dia. heavy duty (2mm thick) pvc conduit on surface with one number 1.5 sq. mm. frlsh pvc insulated 1100 v grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit. [uppwd sor : 1301 (c)] 5 supply and wiring of submain with two number 4 sq.mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 20mm dia heavy duty (2mm thick) pvc conduit on surface with one number 2.5 sq. mm. multistrand copper conductor cable as earth continuity wire drawn in conduit. [uppwd sor : 2018, 211 (c)] 6 supply and wiring of submain with four number 10 sq. mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2 mm thick ) pvc conduit on surface with two number 6 sq. mm. frlsh pvc insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. [uppwd sor : 2018, 268 (c)] 7 supplying and drawing of utp 4 pair cat 6 in the existing surface/ recessed steel/ pvc conduit as required. 1 run of cable. [dsr : 2018, 1.53.2] 8 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm [dsr : 2018, 1.21.2] 9 supply and laying of aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. i 120 sq. mm 3 1/2 core [uppwd sor : 2018, 501 (o)] ii 70 sq. mm 3 1/2 core [uppwd sor : 2018, 501 (m)] iii 50 sq. mm 3 1/2 core [uppwd sor : 2018, 501 (l)] iv 16 sq. mm 4 core [uppwd sor : 2018, 501 (i)] 10 supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. the armouring of the cable shall be properly connected with the earth as per direction of engineer incharge. i 120 sq. mm 3 1/2 core [uppwd sor : 2018, 503 (o)] ii 70 sq. mm 3 1/2 core [uppwd sor : 2018, 503 (m)] iii 50 sq. mm 3 1/2 core [uppwd sor : 2018, 503 (l)] iv 16 sq. mm 4 core [uppwd sor : 2018, 503 (i)] 11 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer incharge. i 120 sq. mm [uppwd sor : 2018, 504 (j)] ii 70 sq. mm [uppwd sor : 2018, 504 (h)] iii 50 sq. mm [uppwd sor : 2018, 504 (g)] iv 35 sq. mm [uppwd sor : 2018, 504 (f)] v 25 sq. mm [uppwd sor : 2018, 504 (e)] vi 16 sq. mm [uppwd sor : 2018, 504 (d)] 12 supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspenders etc as required. i 100 mm width x 50 mm depth x 1.6 mm thickness [dsr : 2018, 4.1.2] 13 supply & erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, m.s. channel base with bottom and top cable entreis electrical control panel with tpn mccbs (four pole 36 ka with thermal magnatic release)switches complete and instrument chamber etc.complete in all respects. the instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (kva,p.f,kw etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. the panel board shall have suitable capacity electrolytic alumininum busbars as per is8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as cmc/bmc support with deteachable side covers and shall be suitable for extension on the sides. the mccbs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. the job includes the grounting of the board as per directions of engineer in charge. all out goings of 100 amp and above shall have an ammeter. the panel board shall be fabricated with crca sheet with a minimum thickness of 1.6mm/2mm. cubicle type switch board shall be of cat a & b only. [uppwd sor : 2018, 811(a)] i incoming 100 amp. mccb 1 no outgoing 63 amp. mccb 2 nos. cat. b.pannel cubicle type [uppwd sor : 2018, 811(a)] ii incoming 400 amp. mccb 1 no outgoing 100 amp. mccb 3 nos. 63 amp. mccb 2 nos. cat. b.pannel cubicle type [uppwd sor : 2018, 813(e)] 14 supply & erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, m.s. channel base with bottom and top cable entreis starter control panel with tpn mccbs (four pole 36 ka with thermal magnatic release)switches complete and instrument chamber etc.complete in all respects.the panel board shall have suitable capacity electrolytic alumininum busbars as per is8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as cmc/bmc support with deteachable side covers and shall be suitable for extension on the sides. the mccbs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. star delta starter suitable upto 10 hp motor 15 s & f surface/flush mounting 12ways tpn distribution board with additional metal door with mcb complete in all respect,as directed at site by engineer in charge. (1 no. 63a 4p mcb as incomer, 36 nos. 6 32a sp mcb as outgoing & 12 way db) [uppwd sor : 2018, 1029 (a) + 1017 + 1002] 16 supply, installation, testing & commissioning of 20 kva capacity 3 ph input & 1 ph output with 30 min backup ups complete with all accessories. 17 supply and burring of safe earthing electrode t 39 (hot dip galvanized), length up to 3000mm, outer pipe 76mm inner dia 38mm terminal dia 12 mm ,outer gi pipe of 16 swg and inner gi pipe of 12 swg with hot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. framevwith hinged cover & masonary housing. (from electrode terminal to switch board, cost of 25 x 3 gi. strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. [uppwd sor : 2018, 725 (d)] 18 supply and laying of 25mm x 3mm g.i. strip from earth electrode directly in the ground as required complete in all respect. [uppwd sor : 2018, 716] 19 supply, installation, balancing and commissioning of fabricated at site aluminium sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. i thickness 0.80 mm sheet (22g) 20 supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell nitrile rubber (class o) insulation on existing duct after applying suitable adhesive for nitrile rubber. the joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. i 19 mm [dsr : 2018, 16.23.1] 21 supply, installation, testing and commissioning of gi volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. [dsr : 2018, 16.13] 22 supply, installation, testing & commissioning of flexible canvass connection to connect the air handling unit & supply and return air duct as per specification & complete in all respect. 23 area zonal valve box for required a services as per iso 7396 standard. having isolation valve, pressure gauge, locking arrangement, transparent breakable front to break in case of emergency.uit must be manufactured as per ce and iso 13485 certiying facility as per specification and approved make by up govt. health dept.. i 6 services (oxygen, nitrous, air 4, air 7, agss/co2, vaccum, ) 24 copper piping : copper pipes for medical gases, complete with elbows, flanges, specials, others fittings, ad steel supports, the coper pipe should be of solid drawn seamless deoxidized un arsenical tempered and of degreased material conforming to bs en 13348/astm 8819 of copper pipe must be certified and inspected by third party inspection agency like lloyds/sgs/tuv etc. as per approved make attached. i 15 mm od ii 22 mm od iii 28 mm od 25 floor/area isolation valve all valves are to e ball valves type and ptfe or teflon seals, they shall be suitabke for a working pressure of 10.2 kg/cm2 gauge. valves shall be fitted into the pipeline by means of capillary hard soldered joints containing silver. it should be open/close with help of handle with rotation of 90 degree. as per approved make attached. i 22 mm ii 28 mm total quantity : 1...

Military Engineer Services - Uttar Pradesh

32853518 certain sanction works ( 05 nos ) in age br i and age em under ge babina 1 excavationin trenchesnot exe 1.5 mtrs wideand not exe 1.5 mtr in depth and getting outin any type of soiletc complete all as specified and directed . 2 excavation in post holes ( or similar holes ) each not exc 0.5 cum , getting out in any type of soilsandremoving surplus soil to a distance not exc 50m and as directed. 3 surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard / dense soil comlete all as specified and directed. 4 returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed. 5 removing excavated soils / material to a distance n exc 50m and deposited where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed. 6 m&l for moorum laid in layers n exc 15 cm thickness , spread , levelled , rammed and watering as in floorsetc complete and all as specified 7 m&l for hard core of broken boulders / stone of gauge n exc. 63 mm, deposited, spreading, leveling watering and well ramming to true surface in layers not exceeding 15 cm thick each layer complete all as specified and directed. 8 demolition of brick work / stone masonary built in cement mortar of nay description , any position and anylocation and as direcetd 9 m&l for brick work with fly ash bricks ( fasb ) straight or curved on plan exc 6 m radius built in cement mortar ( 1 : 4 ) etccomplete all as specified and as directed. 10 m&l for pcc 1:3:6 type c 2 using 40mm graded stone agg as in filling and mass concrete , sub base / flooring complete all as specified and directed. 11 m&l for pcc 1:4:8 type d2 using 40mm graded stone aggregatesas in foundation filling etccomplete all as specified and directed. 12 m&l for pcc 1:2:4 type b 2 using 40mm graded stone agg as in filling and mass concrete, sub base / flooring complete all as specified and directed. 13 m & l for pcc work of flexural strength of 40 kg / sqcm using cement 400kg / cumas in pavement , floors & hard standing, laid in panels not exceeding 30 sqm each , panel shall be formed using mild steel members of adequate size and thichness to create 10 mm wide joints , surfaces ofconcrete finished even and fair to desire level etc complete all as specified and as directed. note : ( i ) cost of sample testing for design mixto ensure flexural strength 40 kg / sqcm will be borne by the contractor . min cement content shall be 400 kg / cum of concrete . in case cement required more than 400 kg shall deemed to be included in the quoted rate and nothing extra shall be admissible on this account . ( ii ) joint shall be measured and paid seperately . 14 m&l for filling of contraction joints 10 mm wide x 30 mm deep and tfilled with sealing compound grade a etc complete as directed 15 m & l for precast rcc1:1.5: 3 type a 1 using 20 mm graded stone aggregate as in lintel upto 1.50 mtr span etc complete all as specified and as directed. note : reinforcement shallbe paid seperately 16 s&f, 2nd class hard wood ( sal ) as in scantling, wrought timber frame work as in members of trusses like rafter , purlins etc similar etc complete and as directed. note : the moisture and species test is manadatory prior to used timber and shall be got tested from govt lab or from nibl approved lab . no payment of timber shall be made unless got tested and test results thereof found satisfactory 17 m&l for mild steel tmtbars8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookingends and binding with and includingmild steel wire ( annealed ) not less than 0.9mm dia or securing with clips etc complete all as specified and directed .make : as specified in tender documents 18 s&f mild steel work as in tubular trusses including special shaped washer etc complete using erw or induction butt welded tubes conforming to is 1161 1979 grade st 240 with and including one shop coat of zinc chrominium primer paint complete all as specified and as directed. 19 s&f mild steel work as in roof trusses ( framed ) trussed , purlins , crane gentries rails and fastenings and heavy brackets framing ( beam, tee, angle, channel or flat sections ) incl distance pieces , cleats etc of 290gde e 165 etc complete all as specified and as directed. make : as specified in tender documents 20 s &f mild steel hold flat iron 40x5 mm thick as in wind tie over roof including securing bolts including driling holes etc complete and as directed make : as specified in tender documents 21 s&f mild steel ( plain ) plates , square cut or notched ( ordinary and counter sunk ) forming holes of suitable dia if requiredand fixed to pipe by electric welding alround the neck of pipe etc complete and as directed. 22 s&f mild steel screw bolts ( machine made ) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 10 cm length and 11 to 15 mm dia 23 dismantling of timber scantling 40 sqcm and over in section fixed in any position as framed work complete all as specified and directed 24 taking out / dismantlingof existing roof treatment of any description , any position over roof including taking out plain cement concrete of any description to the thckness as directedetc complete and including lowering down complete waste materials to the ground on a place where directed and includingremoval of the same to a distance exc 250 mtr but n exc 500 mtr as directed .note : the cost of lowering down and removal deemed included in unit rtae quoted by the tenderer. 25 m&l for cutting out cracks to v section in existing roof or terracing , cleaning out , wetting and sealed solidly with hot mixture of bitumen and dry sand in proportion of 1:1 by weight etccomplete and as directed. 26 m&l for cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove sealed with cement mortar 1:3 complete and as directed. 27 m&l for p.c.c 1:2:4 type b 1 using 20 mm graded stone aggregate as in padding laid to slope over roof and surface finished even and fairetccomplete all as specified and as directed. note : the thickness of pcc shall not be exceeded more than75 mm at any place 28 m&l for p.c.c 1:2:4 type b 0 using 12.5 mm graded stone aggregate as incoping andon roof etccomplete all as specified and as directed. 29 supply only water roofing compound ( liquid ) isi marked etc complete and as directed 30 m&l for 10 mm thick rendering in cement mortar 1:4 on concretesurfaces of roof when concrete is stillgreen mixed withwater proofing compound ( liquid ) @ 200 ml perbag of cement of 50 kgs , surface finished even and fair enough to receive water proofing traetment etc complete all as specified and as directed. note : wpc shall be measured and paid seperately 31 m&l for providingwater proofing treatment over roof by applying the following operations : ( a ) preparation of plastered surface by cleaningwith water and leave the sufaces till to become surface total dry . ( b ) applyingfirst coat of bitumen primer conforming to is 3384 @ 0.4kg / sqm on plastered surface ( c ) applying app based polymeric membrane 3mm thick ( minimum thickness ) and weightnot less than 3kg / sqm , reinforced with polyester non woven fabric ( wt not less than 150 gms / sqm ) over on primed surfacelaid with 100mm side lap / end lap on prepared surfaces as per manufacturers instructions and under strict supervision of manufacturers tenchnical representativeetc and applying two coats of bituminous based aluminum paint @ 100 ml / sqm each coat etc complete and as directed. note : testing of app membrane is mandatory and contractor will not be allowed to carry out the work untill results are obtained and found satisfactory .cost of testing and samples ( 3nos ) deemed to be included in unit rate quoted by thetendrer and nothing extra on this account will be admissible . ( ii ) the cost of casting onecement plate of size 600 mm x 450 mm , 10 mm thick rendering in cm 1:3 in each building incl writing materials shall deemed to be included in the unit rate quoted by the tenderer. 32 m &l for plain concrete cement tiles ( cement ) 30cm x 30cm x 25mm set and jointed and pointedin neat cement slurry on roof over & including 15mm thick screed bed in cm ( 1: 4 ) and joint between the tiles to be filled with chemiucal like grout etc complete all as specified and directed. 33 dismantling wall / ceiling boards of any description any thickness incl exiting snap grid framework of any descriptionand as directed. 34 m&l for snap grid ( 600 x600 mm ) ceiling using aluminium anodised sectionsie main tee section of 36.5x25x1.4mm size ( wt not less than 0.24kg / rm ) , wall angle of size 40x25x2mm size ( wt not less than 0.36kg / rm ) , cross tee section 23.5x26.4x1.4mm size ( wt not less than 0.191kg / rm ) andsnap grid shall be fixed to ceiling by supporting hangers consisting of 6 mm dia mild steel bar made to shape including providing mild steel flat iron cleat with 40x3 mm and fixed with expansion dash fastener n exc 1.20 mtr both ways fixed to roof etccomplete all as directed. 35 m&l for for 4 mm thick high pressure steam cured non asbestos fiber cement designer board of size 600mm x 600mm as in ceiling complete all as specified and directed with and including aluminium anodised snap grid frame. 36 dismantling asbestos cement , galvalume , fibre sheet ( plain , corrugated , semi corrugated ) and as direcetd 37 s&f pre painted galvalume aluminium zinc coating gi based corrugated steel sheet 0.50mm thickcolouredhaving tensile strength of 550 mpa as in roof covering andfixed with self tapping screws and as directed . 38 s&f pre painted galvalume aluminium zinc coating gi basedplain steel sheet 0.50mm thickcolouredhaving tensile strength of 550 mpa as in cladding / wall fixed with self tapping screws and as directed . 39 m&l for 75 mm thick p.c.c 1:3:6 type c 1 using 20 mm graded stone aggregate as in plinth protection laid in alternate panels made of 10 mm thick plywood ( size of each panel shall not exceed 12 sqm ) and finish the surface even and smooth withoutusing extra cement including filling of jointwith bitumen mastic ( 1 part bitumen mixed with 3 part dry sand ) etc complete all as specified and as directed. note : cost of form work for forming joints and jointing materials deemed to be included in unit rate quoted by the tenderer. 40 m&l for non skid ceramic coloured tiles 7 to 8 mm thick ( square / rectengular ) dark ( premium quality ) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurryand pointed in white or coloured cement to match over 15 mm thick screed bed in cm 1:6 etccomplete all as specied and directed. 41 m&l glazed ceramic coloured tilesdark ( premium quality ) 7 to 8 mm thick size 300x600 mm joint free over 15 mm thick rendering in cement mortar 1:4 in skirting / dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile etc complete all as specified and directed . 42 taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for key, scrubbingdown with water etc.complete all as specified. 43 m & l for 15 mm thick rendering in cement mortar 1: 6 on fair faces of brick work or concrete surfaces , surface finished even and smoothwithout using extra cement complete all as specified and as directed. 44 m & l for 15 mm thick rendering in cement mortar 1: 6 on other than fair faces of brick work or stone masonary , surface finished even and smoothwithout using extra cement complete all as specified and as directed. 45 m & l for prepration of newly plastered surfaces of walls appying two coat of cement base paint over a coat of primeretc complete all as specified and as directed . 46 m & l for complete removal of existing treatment from walls and appying two coat of cement base paint over a coat of alkali resistant primerincluding necessary prepration of surface complete all as specified and as directed. 47 m & l for applying two coat of white wash on wallsincludingnecessary preparation ofsurfaces all as specified and directed. 48 m&l for preparation of old decorated surfaces of wall including cornices, plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material etc and applying two coat of white wash complete all as specifiedand directed. 49 m&l for preparing new surfaces of steel of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paints over one coat of red oxide primer all as specified. 50 s&f 100 mm bore cast iron soil waste and vent pipe spun pipein any length with or without ear and jointed in cm 1:1 fixed to wallswith ms clamp made of flat iron 50x5 mm and bolt grouted in wall withpcc 1:2:4 type b 0 using 12.5 mm graded stone aggregates and taking out existing pipe of any description etc complete all asspecified and directed. 51 s&f cast iron bend any radius 100 mm bore etc compete and as directed 52 taking up or down existing steel tubing and connections including cleaning for refixing etc complete all as specified and as directed for 15 mm bore 53 taking up or down existing steel tubing and connections including cleaning for refixing etc complete all as specified and as directed for 20 mm bore 54 supplying, fixing, jointing and testing 15 mm dia galvanised iron tubing medium grade isi marked with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed 55 supplying, fixing, jointing and testing 20 mm dia galvanised iron tubing medium grade isi marked with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed 56 taking down old existing unserviceable tank pvc ( hdpe ) and of capacity exc250 ltrs but n exc 500ltrs complete as direcetd 57 s&f 500 ltr capacity or rotational moulded polyethylene water storage tank ( cylindrical vertical with closed top ) white , isi marked , triple layered construction hoisted and fixed in position including s&f 20mm dia gi pipe medium grade washout pipe 450mm long with plug and 20mm dia gi pipe medium grade overflow pipe 600mm long with fitting etc complete all as specified in ssr part i 2009 complete all as specified and as directed. 58 s & fball valve highpressure of ptmt with epoxy coated aluminium rod & highdensityplastic ball screwed for iron pipe 20 mm dia and fixed in new tank ( minimum weight 20mm 210 gm ) complete all as specified. 59 s & f in repairs ball valve highpressure of ptmt with epoxy coated aluminium rod & highdensityplastic ball screwed for iron pipe 20 mm dia and fixed in new tank ( minimum weight 20mm 210 gm ) complete all as specified. 60 s&f20 mm gun metal gate valve ( isi marked ) with iron wheel head screwed both ends for iron pipe etc complete as directed. 61 s&fin repair 20 mm gun metal gate valve ( isi marked ) with iron wheel head screwed both ends for iron pipe etc complete as directed. 62 demolition of cement concrete ( unreinforced ) inground floors and paving n. exc 15 cm thickness below or above ground level complete all as specified and as directed. 63 taking down carefully aluminium / copper point wiring on battenor in pvc conduit or in ms conduit with gi earth wire etc ( for light, fan, socket or power point ) complete , including taking out fixtures and fittings such as switches , ceiling roses, pendents, regulators , sockets, light fitting etcremoving materials to store for keeping in safe custudy or for taking credit ( as per schedule of credit for dismantled / taken out items ) and making goodthe disturbedsurfaces of walls, floors, ceilings etc and as directed . 64 taking down carefullyexisting wooden board , main switch, mcb db boxes, tpn boxes, cut out, etc of any size anycapacity fromboards completeall as specified and as directed. 65 taking down carefully sub main wiring with any cable / service connection twin core from wall / lt pole of any size of aluminum with wooden batten and or through rigid conduit including gi wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed. 66 m & l for surfacepoint wiring ( inpvc conduit ) one light pointcontrolled by one switch with pvc insulated and unsheathed flame retardant low smoke ( frls ) cable of 1.5 sqmm ( nominal area ) with stranded copper conductor single core 1100 volts grade in and including non metelic rigid pvc conduit not less than 19 mm dia, clip, withms terminal boxes ( not less than 1.6mm thick ) including earth dollywithframe plates with matching cover plates all modules including 1.5 sqmmstranded copper conductor green as continuous earth wire with lugs complete all as specified and as directed . note : quoted rates shalldeemed to be inclusive for provision of covering sunken boards / terminal boxes / junction boxes of any shape and size with 3mm thickisi marked hylam sheet / backlite sheet cover fixed with suitable brass screws and cup washers. 67 all as per srl item no. 66 above but one fan / exhaust point controlled by oneswitch ®ulator. 68 all as per srl item no.66 above but one 3 / 5 pin5 amp socket outlet point controlled by oneswitch on independent board. 69 all as per srl item no.66 above but one 3 / 5 pin5 amp socket outlet point controlled by oneswitch on same board. 70 description all as per item no 66above but for power point wiring using 2.5 sqmm single core multi stranded copper conductor pvc insulated and unsheathed, flame retardant low smoke ( frls ) cable for 3 / 6 pin 15 amp socket outlet controlled by one switch on independent board with and including 1.5 sqmmstranded copper conductor green as continuous earth wire with lugs complete all as specified and as directed. 71 m & l for concealedpoint wiringone light pointcontrolled by one switch with pvc insulated and unsheathed flame retardant low smoke ( frls ) cable of 1.5 sqmm ( nominal area ) with stranded copper conductor single core 1100 volts grade in and including non metelic rigid pvc conduit not less than 19 mm dia, clip, withms terminal boxes ( not less than 1.6mm thick ) including earth dollywithframe plates with matching cover plates all modules including 1.5 sqmmstranded copper conductor green as continuous earth wire with lugs complete all as specified and as directed .note : ( i ) quoted rate shall be deemed to include the cost of cutting chases in walls / pillars / column etc. of any description for concealing the conduit to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. the portion of point wiring at ceiling shall be in surface pvc conduit / casing & caping of suitable size as directed fixed on ceiling surface with using pvc rawl plugs. ( ii ) fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of schedule `a. ( iii ) the quoted rates shall be deemed to be inclusive for provision of covering sunken boards / terminal boxes / junction boxes of any shape and size with 3mm thickisi marked hylam sheet / backlite sheet cover fixed with suitable brass screws and cup washers 72 all as per srl item no. 71 above but one fan point controlledby oneswitch ®ulator. 73 all as per srl item no.71 above but one 3 / 5 pin5 amp socket outlet point controlled by oneswitch on independent board. 74 all as per srl item no.71 above but one 3 / 5 pin5 amp socket outlet point controlled by oneswitch on same board. 75 description all as per item no 71above but for power point wiring using 2.5 sqmm single core multi stranded copper conductor pvc insulated and unsheathed, flame retardant low smoke ( frls ) cable for 3 / 6 pin 15 amp socket outlet controlled by one switch on independent board with and including 1.5 sqmmstranded copper conductor green as continuous earth wire with lugs complete all as specified and as directed. 76 s & f switch piano flush button type10 amp, single pole , one way , ac , 230 volts , 50 hz complete all as specified and asdirected. 77 s&fsocket outlet 2in 1 , 3 pin , 10 amp , ac , 230 volts , 50 hzcomplete all as specified and asdirected. 78 s & f switch piano flush button type 20 amp, single pole, one way , ac , 230 volts , 50 hz complete all as specified and asdirected. 79 s & fsocket outlet 2 in 1, 10 amp and 20 amp, ac , 230 volts , 50 hz complete all as specified and asdirected. 80 s & fdelux fanregulator rotary, step type , ac , 240 volts , 50 hz complete all as specified as directed. 81 s & flamp holder, pvc / urea type with back plate , ac , 230 volts , 50 hz , isi marked suitable for batten fittingscomplete all as specified as directed 82 s&f ceiling rose, surface bakelite 65 x50mm three brass terminals, ac , 230 volts , 50 hz isi marked completeall as specified and asdirected. 83 s & f9 / 10w led retrofit ball lamp holder base b 22, bipin type ac 230 volts 50 hz with pf not less than 0.95 with polycorbonate body and aluminium heat sink complete all as specified as directed. 84 s&f for sub main wiring with pvc insulated, unsheathedflame retardant low smoke ( frls ) 2 single core cable 1100 volts grade withcopperconductor of size 10 sq mm ( nominal area ) multi stranded drawn into new non rigid metellic pvc conduit with and including 6 sqmm green stranded copper conductor as contineous earthwire withlugs complete all as specified and as directed. note:two run of single core pvc cable with one run of earth conductor cable and conduit shall be measured as one unit. ( ii ) cost of new pvc conduit including conduit accossoriesshall be deemed to be included in unit rate quoted by the tenderer . 85 s&f for sub main wiring with pvc insulated, unsheathedflame retardant low smoke ( frls ) 2 single core cable 1100 volts grade withcopperconductor of size 6 sq mm ( nominal area ) multi stranded drawn into new non rigid metellic pvc conduitwith and including 4 sqmm green stranded copper conductor as contineous earthwire withlugs complete all as specified and as directed. note:two run of single core pvc cable with one run of earth conductor cable and conduit shall be measured as one unit. ( ii ) cost of new pvc conduit including conduit accossoriesshall be deemed to be included in unit rate quoted by the tenderer . 86 s&f tpn db dpx 125 mccb dbs 4 way double door with provision for dpx 125 mccb and as incomer and sp / tp mcbs as out going no of modules dpx 125 + 12 etc complete all as specified and directed. 87 s&f mccb , 200amps, 415 volts, 4 p , 50hz, having 36 ka rupturing capacitywith electronic trip arrangment and setting screw upto 70% including making connection with excisting cable with connection and materials like copper strips, lugs, nut & bolts etc. complete all as specified and as directed . 88 s&f mccb , 100amps, 415 volts, 4 p , 50hz, having 25 ka rupturing capacitywith electronic trip arrangment and setting screw upto 70% including making connection with excisting cable with connection and materials like copper strips, lugs, nut & bolts etc. complete all as specified and as directed . 89 s&f mccb , 63amps, 415volts, 3 phase, 50hz, having 35 ka rupturing capacity, 415 volts with electronic trip arrangment and setting screw upto 70% including making connection with excisting cable with connection and materials like copper strips, lugs, nut & bolts etc. complete all as specified and as directed . 90 s&f mccb , 63amps, 415volts, 3 phase, 50hz, having 16 ka rupturing capacity, 415 volts with electronic trip arrangment and setting screw upto 70% including making connection with excisting cable with connection and materials like copper strips, lugs, nut & bolts etc. complete all as specified and as directed . 91 s&f sheet metal enclosure box with hinges door suitable for mccb 63 amp to 100 amp with all necessary fixing arrangementetc for walletc. complete all as specified and as directed . 92 s&fsheet metal enclosure double door concealed suitable for distribution boards when mcbs to be used having 100amp rated bus bar 8 ways 240 v complete all as specified and as directed. 93 s&fmcb single pole and neutral 40 amp 240 v , 10ka , c series, isi marked complete all as specified and as directed with copper lugs. 94 s&fmcb single pole and neutral 63 amp 240 v , 10ka , c series, isi marked complete all as specified and as directed with copper lugs. 95 s&fmcb tpn 63 amp 240 v , 10ka , cseries, isi marked complete all as specified and as directed with copper lugs. 96 s&fmcb single pole 6 to 32amps 240 v, 10ka, c series, isi markedcomplete all as specified and as directed with copper lugs. 97 s&fin repairs 20 w led, 6000k decorative ultra slim linear fitting , extruded aluminium , environmental friendly, energy efficient incl 20 w lamp fitted incl wiring upto and terminating into existing ceiling rose complete all as specified and as directed. 98 s&f 36w 2x2 led fitting ultra mordern ceiling mounted luminaire suitable for armstrong / grid ceiling in ms housing with high brightness leds incl wiring upto and terminating into existing ceiling rose. 99 s&f wall mountedfan 600 mm sweep turbo force aerodynamic desined blade for high air deleivery complete incl all necessary fixing arrangements and as directed. 100 s&f ceiling fan 1200mm sweep bee ratedac single phase 230 volts etc connecting with flexible cable 3 core copper conductor of size 23.0 / 0076 of suitable length from celling rose complete all necessary arrangement of hanging of celling fan ( gi pipe hook etc ) as specified and as directed. 101 s & f exhaust fan, ac , singe phase , 230 / 240 volts , 300 mm sweep , noiseless light weight rust proof steel body self closing louvers and blades, speed1400complete with all arrangement of making hole complete all as specified and as directed. 102 s&f for replacement & testing commissioning of outdoor type bus bar panel padestel type weather proofms cubical panelboard made of3 mm crca ms sheet , size 110 cm x 80 cm x 40 cm, 4 nos of aluminium bus bar of 500 amp capacity including providing mccb , 4 pole , 320 amp , repturing capacity35 ka , adjustable type ( ics =icu=100% ) including one coat of redoxide and two coat of enamel paint powder coated, mounted on mild steel channel of suitable sizeand providing pcc work inpcc1:3:6 type c 2, 60 cm height above gl over 300 mm thick pcc 1:4:8 type d 2 ( using 40mm graded crushed stone aggregate ) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on dmc / epoxy insulator all as specified & directed. 103 s&fnew generation energy saving and environmental friendly long life led flood light made up of innovative die cast aluminium housing high power led as lighting source with ip 66 power consumption 30 watt complete input voltage of 150 240 volt ( nominal rated voltage 240 volt ) completeall as specified and directed. 104 s&f in replacement new generation security light fitting 1 x 36 w led , envoirnmental friendly long life , made up of of innovative die cast aluminium housingwith high power led as light source withip 66 protection , power consumption 45 watt complete input voltage of 150 240 volt ( nominal rated voltage 240 volt ) includingelectric connection with1.5 sqmm 3 core pvc insulated and pvc sheathed cable stranded copper conductor from junction box to security light etc complete as specifiedand as directed. 105 supplying , laying & testing in replacement cablexlpe insulatedscreenedpvc bedded armoured with galvanised steel wire or tape, electric power cable heavy duty 1100 volt gradealuminium conductor of size 50x3.5coreincluding taking out acsr / ug cable from any location etc complete all as directed. etc complete all as directed. 106 supplying , laying & testing in replacement cablexlpe insulatedscreenedpvc bedded armoured with galvanised steel wire or tape, electric power cable heavy duty 1100 volt gradealuminium conductor of size25x3.5coreincluding taking out acsr / ug cable from any location etc complete all as directed. etc complete all as directed. 107 supplying , laying & testing in replacement cablexlpe insulatedscreenedpvc bedded armoured with galvanised steel wire or tape, electric power cable heavy duty 1100 volt gradealuminium conductor of size25x 4coreincluding taking out acsr / ug cable from any location etc complete all as directed. etc complete all as directed. 108 supplying , laying & testing in replacement cablexlpe insulatedscreenedpvc bedded armoured with galvanised steel wire or tape, electric power cable heavy duty 1100 volt gradealuminium conductor of size16 x 4 coreincluding taking out acsr / ug cable from any location etc complete all as directed. etc complete all as directed. 109 excavationin trenches in any type of soil not exe 1.5 mtrs wideand not exe 1.5 mtr in depth for laying of pipe / cables etc and getting out incl forming bottom surface to the required level / slope etc complete all as specified and directed . 110 m&l for dry clean sand free from sharp materialsfor cushioning laid in trenches in layers forunder ground electric cablecomplete all as specified and directed 111 supplying and laying precast concrete cable cover class lv type i flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete as directed. 112 supplying and laying gi pipe 50 mm bore medium grade including providing fittings such as elbow, tee, socket etclaid on floors / trenches / walls with complete fixing arrangements and testing etccompleteall as specified and directed . 113 m&l for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick weight n less than 17.25 kgs buried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by gi pipe 15 mm bore ( light grade ) and watering pipe 20 mm bore gi pipe ( light grade ) andchamber of pcc 1:4:8 type d2 using 40 mm graded stone aggregate and coping shall be in pcc 1:3:6 type c1 using 20mm graded stone agg.50 mm thick cover of rcc 1:2:4 type b1 using 20 mm graded stone agg. reinforced with 8 mm dia ms tor bar @ 80 mm c / c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of ssr pt i ( 2009 ) with charcoal dust and saltcomplete and earth leadconnected to earthing test point ( up to main switches, dbs ) completeall as specified &testing on completion. note: ( i ) item includes the cost of 7.5 mtr length gi pipe for protection for gi earth wire. ( ii ) item rates includes the cost of 7.5 mtr earth lead gi earth wire. ( iii ) pcc pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra costof additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. 114 m&l for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick weight n less than 17.25 kgs buried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead strip of size 32x6 mm thick by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by gi pipe 15 mm bore ( light grade ) and watering pipe 20 mm bore gi pipe ( light grade ) andchamber of pcc 1:4:8 type d2 using 40 mm graded stone aggregate and coping shall be in pcc 1:3:6 type c1 using 20mm graded stone agg.50 mm thick cover of rcc 1:2:4 type b1 using 20 mm graded stone agg. reinforced with 8 mm dia ms tor bar @ 80 mm c / c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of ssr pt i ( 2009 ) with charcoal dust and saltcomplete and earth leadconnected to earthing test point ( up to main switches, dbs ) completeall as specified &testing on completion. note: ( i ) item includes the cost of 7.5 mtr length gi pipe for protection for gi earth wire. ( ii ) item rates includes the cost of 7.5 mtr earth lead gi earth wire. ( iii ) pcc pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra costof additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate....

Uttar Pradesh Housing And Development Board - Uttar Pradesh

32651021 electrical / mechanical work in 50 bedded eye hospital at ramai patti tehsil sadar district mirzapur electrical / mechanical work in 50 bedded eye hospital at ramai patti tehsil sadar district mirzapur 1 wiring point for light with 1.5 sq. mm.frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sqmm frlsh pvc insulated multistrand copper conductor cable as earth wire drawn inside the conduit with gp box, modular type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. pwd sor 2018 si no 138(c)+187(a) 2 wiring point for two way light with 1.5 sq. mm. frls pvc insulated multistrand single core copper conductor cable in heavy guage pvc conduit. pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 1.5 sq. mm. frlsh pvc insulated multistrand copperconductor cable as earthwire drawn inside the conduit, gp box and 2no. two way modular type switches and ceiling rose /angle /batten holder on 3 mm. thick phenolic laminated backlite sheet etc. complete in all respects, as directed including matching colour wash.pwd sor 2018 si no 139(c) + 187(b) 3 wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm.frlsh pvc insulated multistrand copper conductor cable as earth wiredrawn inside the conduit withmodular type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. pwd sor 2018 sl no 140(c )+ 187(a) 4 wiring point for call bell with 1.5 sq. mm. frls pvc insulated multistrand single core copper conductor cable in heavy guage pvc conduit. pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 1.5 frlsh pvc insulated multistrand copperconductor cable as earthwire drawn inside the conduit, gp box and modular type bell push or 2 pin shocket etc complete in all respects, as directed including matching colour wash. pwd sor 2018 si no 142(c) + 187(e) 5 wiring point for plug with 1.5 sq. mm.frlsh pvc insulated multistrand copper onductor cable in pvc conduitpartly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm.frlsh pvc insulated multistrand copper conductor cable as earth wiredrawn inside the conduit and modular type switch and socket etc., complete in all respect including matching colour wash.pwd sor 2018 sl no 141(c )+ 187(a) 6 supply and wiring of submain with two number 2.5 sq.mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) pvc conduit partly laid in slab alongwith the reinforcement before concreting and partly concealed in wall with 1 nos. 1.5 sq. mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. including matching colour wash. pwd sor 2018 sl no 1307(c ) 7 supply and wiring of submain with two number 4 sq.mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with one no. 2.5 sq. mm. frlsh pvc insulated multistrand copper conductor cable as earth continuity wire drawn in conduit including matching colour wash etc. complete in all respect. pwd sor 2018 sl no 221(c ) 8 supply and wiring of sub main with two number 6.0 sq.mm frlsh pvc insulated 1100 v grade multstrand single core copper conductor cable in 20 mm dia heavy duty(2mm thick) pvc conduit partly concealed in wall and partly laid in slab along with reinforcement before concretiing with 1 no. 4.0 sq.mm. frlsh pvc insulated multstrand copper conductor cable as earth continuity wire drawn iin conduit including matching colour wash. complete in all respect pwd sor 2018 si no 222(c) 9 supply and wiring of 4 number 6 sq. mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2mm thick) pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with 2 nos 4 sq.mm. frlsh pvc insulated copper conductor cable as earth continuity wire drawn in conduitincluding matching colour wash etc. complete in all respect..pwd sor 2018 sl no 277(c ) 10 supply and wiring of 4 number 10 sq. mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2mm thick) pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with 2 nos 6 sq.mm. frlsh pvc insulated copper conductor cable as earth continuity wire drawn in conduitincluding matching colour wash etc. complete in all respect..pwd sor 2018 sl no 278(c ) 11 supply and wiring of sub main with 4 number 16.0 sq.mm frlshpvc insulated 1100 v grade multstrand single core copper conductor cable in 40mm dia pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with two number 10 sq.mm. rlsh pvc insulated copper conductor cable as earth continuity wire drawn in conduitincluding matching colour wash etc. complete in all respect. pwd sor 2018 si no 279 (c) 12 supply and fixing hexagonal/round g.p. fan box of approved make made up of 1.0 mm thick isi marked g.p. sheet spot welded four to eight holes of 25.4 mm for pipe entry of the box. holes should be semi shuttered type with 0.5 mm g.p. sheet made upper & lower cover duly screwed fitted with 300 mm round zink coated m.s bar x 12 mm & brand name should be embossed. fixing with wiring conduit laid in the r.c.c. roof before concreting along with supply of all material, labor, t&p etc. required for proper completion of the work .pwd sor 2018 s.i.no. 1149 13 supply and fixing of led tube light with metal heavy duty box type batten light fitting 1 x 22 watt suitable for upto 1x22 watt led polycarbonate tube light complete including tube suitabe for both surface & suspended complete in all respect. 2420 system lumens, 110lm/watt pf>0.95, thd<10% cri>80, sheet thicknes 0.8mm, tube with aluminium heat with 5 year warrantee. pwd sor 2018 sl no 1413 cat aaa 14 supply and fixing of led tube light with metal heavy duty box type batten light fitting 2x 22 watt suitable for upto 2x22 watt led polycarbonate tube light complete including tube suitabe for both surface & suspended complete in all respect. 2420 system lumens, 110lm/watt pf>0.95, thd<10% cri>80, sheet thicknes 0.8mm, tube with aluminium heat with 5 year warrantee. pwd sor 2018 sl no 1414 cat aaa 15 supply and fixing of recess/surface mounting round 24 watt to 32 watt cut out min 150 mm height min 40 mm, led down lighter having powder coated die cast aluminium housing with heat sink diffuser/reflector and driver set suitable for 24 hr continuous operation, compelete in all respect. pwd sor 2640 3520 system lumens, 110lm/watt pf>0.95, thd<10% at full load, cri>80, with 5 year warrantee. si no. 1405 cat aaa 16 supply and fixing of water tight oblong 10 watt led bulkhead luminaire with driver set confirming to ip 65 and above protection . complete in all respect. si no. 1417 cat aaa 17 supply and fixing of 36 watt to 46 watt indoor recess mounting led square fitting for armstrong ceiling having powder coated die cast aluminium housing body with extended heat sink and diffuser of special polycarbonate meterial and driver set complete in all respect.pwd sor 2018 s.i.no. 1406 cat a 18 supply and erection of 300 mm sweep ac 230/250 volts, 50 hz exhast fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required connection etc. complete as required mr 19 supply and erection of 400 mm sweep ac 230/250 volts, 50 hz wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required connection etc. complete as requiredmr 20 supply and fixing of electronic fan regulator (modular) 120 280 v. isi marked, on the existing switch board including making connections, required material, labour t&p etc. for proper completion of work to the satisfaction of engineer in charge of work. pwd sor 2018 s.i.no. 1203 (c ) 21 supply and erection of ceiling fan with motor of ac permanent insulation, capacitor rating conforming bee 5 star rating and is:374/79 and also comply with is: 1709/ 1984 with latest amendment. the rated voltage 220/240 volts, 50hz 1 ph ac the fan assemble should consists of down rod, blades, shackle, canopies etc and with double ball bearing system .pwd sor 2018 si no 1501+ 1115 bee 5 star rated 1200 mm sweep 22 s/f of 3mm thick bakelite sheet cover round/hexagonal type for fan box complete with all material, labour t&p as per direction of e/i. 23 s/f of 3mm thickal. sheet junction box cover complete in all material labour t&p as per direction of e/i. 24 supply and fixing of surface/ flush mounting 8 way tpn distribution board with additional metal door without mcb complete in all respect and directed at site by e/i. pwd sor 2018 si no 1027(a)cat a 25 s&f of 6 amp to 32 amp. spmcb (10 ka) c curve pwd sor 2018 si no 1002 cat a 26 s&f of 63 amp. 4 pole mcb (10 ka) c curve pwd sor 2018 si no 1020 (a) 27 supply and fixing of power plug with 20 amp./250 voltflush type modular switch and 5 pin 20 a/250 volt flush type universal modular socketswitch on concealed m.s boxincluding supply of all material, labour t&p etc. required for proper completion of work. pwd sor 2018 si no 1139(a) 28 s & f sheet steel enclosure surface / flush mounting fitted with 30amp. 2pin and earth metal clad scraping earth plug and socket complete in all respect. as directed at site byengineer in charge.1031 (a) 29 s & f surface/flush mounting 4ways v tpn distribution board with additional metal door without mcb complete in all respect,as directed at site by engineer in charge.pwd sor 2018 si no 1026 (c ) 30 s&f of 80 to 100 amp 4 pole mccb (16 ka) thermal magnetic releasepwd sor 2018 si no 1021 31 supply and burring of safe earthing electrode t 39 zn zinc coated, length 3000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal dia 12mm, coating 80 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square c.i. frame with hinged cover & masonry housing. (from electrode terminal to switch board, cost of 25 x 3 g.i. strip will be extra make: as approved in u.p. p.w.d., & c.p.r.i. certified pwd sor 2018 si no 726 (d) 32 supply and laying of 25 mm x 3 mm g.i srtip form earth electrode directly in the ground as required complete in all respects. pwd sor 2018 si no 716 33 supply and laying of 32 mm x 6 mm g.i. strip from earth electrode directly in the ground as required complete in all respect. pwd sor 2018 si no 717 34 providing, laying and fixing 80 mm dia g.i. pipe (medium class) in ground complete with g.i. fittings including trenching (75 cm deep)and re filling etc as required. dsr 2018 si no 18.12.8 35 supplyandlayingof aluminiumconductorpvcinsulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. pwd sor 2018 si no 501 36 10 sqmm 4 core 37 16 sq mm 4 core 38 70 sq mm 3.5 core 39 95 sq mm 3.5 core 40 240 sq mm 3.5 core 41 supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. the armouring ofthe cable shall be properly connected with the earth as per direction of engineer incharge.pwd sor 2018 si no 503 42 10 sqmm 4 core 43 16 sq mm 4 core 44 70 sq mm 3.5 core 45 95 sq mm 3.5 core 46 240 sq mm 3.5 core 47 supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the engineer incharge.pwd sor 2018 si no 504 48 10 sqmm 49 16 sq mm 50 35 sq mm 51 50 sq mm 52 70 sq mm 53 95 sq mm 54 120 sq mm 55 240 sq mm 56 supply and fixing of call bell of approved make on polished mdfeg / teak ply board including making connections etc. complete in all respect. pwd sor 2018 si no 1101 57 supply of franklin france make advanced piezoelectric exciter device based lighting protection system suitable for protection of building against direct lightning strike complete with ealy streamer emission with piwezoelectric device for corona effect) stainlles steel lighting conductor air terminal with event counter with sensitivity 1 ka to 100 ka for 8.20 micro second impulse for 1 ka control over the release of ions positive or negative without additional power supplies requirement required complianece with ip53 enclosures) 58 saint elmo lightening conductor with discharge counter (sensitivity 1 ka, 8/20 microsecound with ip 53 enclosures) 59 elevation rod : 2m. afc2001 two elevation rods for are required for mounting a one lightening conductor mr 60 installation of franklin france make external lightening protection system. 61 supply and fixing of vertical down conductor of 32mm x 6mm g.i. strip etc. on approved clamps on surface for lightning conductor complete in all respects (for two storeyed buildings).p.w.d.s.o.r. 2018 s.i. no.713( c) 62 supply and fixing of testing joint of g.i. strip 32mm x 6mm and 150mm long with g.i. bolts and nut etc. complete in all respect.p.w.d.s.o.r. 2018 s.i. no.719 63 supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. (i)telephone socket outlet dsr no 1.24.6 64 supply and fixing of g.p. modular switch box for 1 / 2 module of approved make made up of 1.0 mm thick isi marked g.p.sheet including adjestable nakka and holes plugged with pvc nylon caps . two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box. holes should be semi shuttered type and fitted with heavy brass earth piller duly screwed & brand name should be embossed. box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and t&p required for proper completion of work as directed at site by the engineer in charge. p.w.d.s.o.r. 2018 s.i. no.1152(a)(i) 1 or 2 module (75mm x 75 mm) 65 supplying and drawing telephone wire following pair 0.5 sqmm fr pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/pvc conduit as required. dsr no 1.18.22 pair 66 supply and fixing and concealing of 20 mm dia. 2mm thick pvc conduit pipe with isi mark embossed and with pvc accessories confirming to is no. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and t&p etc required for proper completion of the work as per directions and to the satisfaction of engineer in charge. sor 2018 si no. 148(a) 67 supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality sor 2018 si no. 1136 68 fire fighting systemproviding, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 3589/is 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : dsr & aor 2019 si no 7 69 150 mm dia 70 100 mm dia 71 80 mm dia 72 65mm dia 73 32mm dia 74 25 mm dia 75 providing laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required. dsr & aor 2019 76 150 mm dia si no 6.2 77 supplying,fixing, testing and commissioning of manual swing typehose reel is:444 complete with heavy duty reel, 20 mm dia. x 30 mtr long, pvc pressure hose pipe , red coloured, ss jet nozzel, 25mm. isolating valve and all other neccessary fixing accesories complete in all respect. dsr no 17:1 78 supplying and fixing single headed internal hydrant valve with instantaneous gunmetal/stainless steel coupling of 63 mm dia with cast iron wheel isi marked conforming to is 5290 (type a) with blank gunmetal/stainless steel cap and chain as required :as per dsr & aor 2019 s.i. no. 9.1 79 supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to is 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : dsr & aor 2019si no. 18.1 80 supplying and fixing 63 mm dia, 15 m long rrl hose pipe with 63 mm dia male and female couplings duly bound with gi wire, rivets etc. conforming to is 636 (type a) as required : dsr & aor 2019 si.no.16.1 81 providing and fixinghose box (600x300x200)size of suitable size made out of 16/18 swg thick having central opening and 4 mm thick glazed glass double door including necessory rubber beading key pocket, handle locking arrengment painting with polyurethene based red paint etc. the words fire hose to be painted on the dooor as per approved drawing complete in all respect. mr 82 supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia ms pipe connection conforming to is 904 as required : 83 2 way 100 mm dia m.s. pipe si no. 19.1 84 supply, fixing, testing and commissioning of 25mm ball valve complete. mr 85 supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. dsr & aor 2019 si no. 20 86 supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required: (main fire pump)(a) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to is : 1520(b) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase, 50 hz, ac supply with ip55 class of protection for enclosure, horiziontal foot mounted type with class f insulation, conforming to is 325.(c) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) suitable cement concrete foundation duly plastered and with anti vibration pads.supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.1620 lpm at 70 m head dsr & aor2019 si no. 1.8 87 supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump)horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.make : kirloskar/ other standard make.dsr no. 2.81620 lpm at 70 m head 88 supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump) a) horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.b) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is : 325.c) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads. make kirloskar/other standard make dsr no. 3.2180 lpm at 70 m head 89 supplying, installation, testing and commissioning of electric driven terrace pump suitable forutomatic operation and consisting of following, complete in all respects, as required: (terrace pump)(a) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to is : 1520 b) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase, 50 hz, ac supply with ip55 class of protection for enclosure, horiziontal foot mounted type with class f insulation, conforming to is 325. (c) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m head 90 automatic control panel(s) fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required : incoming 250a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0 500v with selector switchdigital ammeter (0 250 a) with selector swtich & cts etc.outgoing main fire pump : 125 a 50ka tpn mccbjockey pump : 63 a , 50ka tpn mccb, diesel engin control complete in all respect dsr no. 5.1 91 providing & fixing of pressure switch in m.s. pipe line including connection etc. as required. dsr & aor 2019 si no. 22 92 providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required dsr 2018 si no. 16.8 93 sitc of foot valves with strainer at the suction pipe of fire pumps (in case of negative suction only). make kalpana/kartarsir/advance or equivalent 94 150mm dia 95 100mm dia 96 supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required : dsr & aor 2019 si no 11 97 150 mm dia 98 100 mm dia 99 80 mm dia 100 providing, installation, testing and commissioning of non return valve of following sizes confirming to is: 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required : dsr & aor2019 si no. 14 101 150 mm dia 102 100 mm dia 103 supply and fixingof c02 type fire extinguisher 4.5 kg. capacity (isi marked is : 2878 & tac approved) complete with initial charge and wall bracket, along with supply of all materials and labourfor proper completionof work.pwd sor 2018 si no 1132 104 supply and fixingof fire extinguisher,abc type 6.00 kg. capacity(isi marked is : 15683 & tac approved) complete with initial charge and wall bracket, along with supply of all materials and labourfor proper completionof work.pwd sor 2018 si no 1131(a) 105 supply and fixing of self glow type exit sinage. 106 sitc ofsprinkler 68° deg, complete in all respects. (make: omex/ life guard/safex) dsr 2019 si no. 21.1pendent type 107 fire alarm system worksupplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card,minimum 320 character graphics/ lcd display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (eprom), power supply unit (230± 5% v, 50 hz), 48 hrs back up with 24 volt sealed maintenance free batteries with automatic charger. the panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under sh: pa system) and shall be complete with all accessories . the panel shall be compatible for ibms system with open protocol bacnet/ modbus over ip complete as per specifications. dsr 2018 si no 17.2.1.1two loop panel. 108 supplying, installation, testing & commissioning of intelligent analog addressable photo thermal detector complete with mounting base complete as required. dsr 2018 si no 17.2.4 109 supplying, installation, testing & commissioning of response indicator on surface/recessed ms box having two led, metallic cover complete with all connections etc as required.dsr 2018 si no 17.2.5 110 supplying, installation, testing & commissioning of addressable phone control module complete as required. dsr 2018 si no 17.2.11 makeinnel/simplex/tyco 111 supplying, installation, testing & commissioning of addressable manual call point complete as required. dsr 2018 si no 17.2.14 112 supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. dsr 2018 si no 17.2.15 113 supplying, installation, testing & commissioning of addressable fire control module complete as required. dsr 2018 si no 17.2.10 114 supplying, installation, testing & commissioning of faultisolator complete with base as required. dsr 2018 si no 17.2.7 115 supplying, installation, testing & commissioning of repeater panel wih 320 character/ touch screen lcd display with inbuilt reset ackowledge and silence switches complete as required.dsr 2018 si no 17.2.3 116 supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000v rated with annealed copper conductor having xlpe insulation, steel wire armouring & frls outer sheath complete as required.. dsr 2018 si no. 17.5.2 117 supplying, installation, testing & commissioning of 6 zone,voice alarm controller with usb, mp3 player (including 6 zonebutton paging station) with seamless integration facility withmain fire alarm panel for voice evacuation complete asrequired dsr 2018 si.no.17.3.1 118 supplying, installation, testing & commissioning of 1.5/3/6w metal box ceiling/wall speakers complete as required.dsr 2018 si.no.17.3.3 119 supplying, installation, testing & commissioning of digital audio amplifier 50 watt, 25v rms operating at 240 volt ac supply complete as required.dsr 2018 si.no.17.3.6 120 supplying, installation, testing & commissioning of voice command keypad 6 zone, with microphone assembly complete as required.dsr 2018 si.no.17.3.9 121 tubewell workboring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in is: 2800 (part i), including collecting samples from different strata, preparing and submitting strata chart! bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90 metre depth below ground level. dsr 2019 sino. 23.1.1 122 350 mm dia upto 60 msino. 23.1.1.2 123 60 90 msi no. 23.1.1.1 124 90 150 msi no. 23.2.1.1 125 supplying, assembling, lowering and fixing in vertical position in bore well, erw (electric resistance welded) fe 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to is: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of engineer in charge. dsr 2019 si no. 23.10 126 150 mm nominal size dia having minimum wall thickness 5.00 mm si no. 23.10.2 127 200 mm nominal size dia having minimum wall thickness 5.40 mm si no. 23.10.3 128 supplying, assembling, lowering and fixing in vertical position in bore well, erw (electric resistance welded) fe 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type a) of required dia, conforming to is: 8110, of reputed and approved make, having wall thickness not less than 5.40 mru, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fitting & accessories, all complete, for all depths, as per direction of engineer in charge. dsr 2019 si no. 23.11 150 mm nominal size dia si no. 23.11.2 129 providing and fixing bail plug/ bottom plug of required dia to the bottom of pipe assemblv of tube well as oer is:2800 (dart n.dsr 2019 si no. 23.15 150 mm dia si no. 23.15.2 130 providing and fixing m.s. clamp of required dia to the top of casing! housing pipe of tube well as per is: 2800 (part i), including necessary bolts & nuts of required size complete. dsr 2019 si no. 23.14(i) 200 mm clamp si no. 23.14.3 131 supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. dsr 2019 si no. 23.6 132 development of tube well in accordance with is : 2800 (part 1) and is: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by v notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, ilc disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of engineer in charge dsr 2019 si no. 23.12 133 providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing! casing pipe, rmovable as per requirement, all complete for borewell of: dsr 2019 si no. 23.13 200 mm dia si no. 23.13.3 134 500 lpm 52 m head of k s b make submersible pumping plant sitc submersible pump set suitable for clear and cold water with bronze impellers and built in non return valve and suitable to run on 400 volts, 3 phase 50 hz a.c. supply at 2900 rpm (nominal) speed and complete with 3 mts. submersible cable. 135 sitc of sheet steel fabricated cubical type wall mounting type panel with front opening door. the panel will be complete with internal wiring and will have 3 nos. instruments fuses and 3 nos. toggle switches. 136 main piping and valves (01 no ci df reflux valve, 02 no ci df sluice valve, 01 no ci df bend, 01 no enlarger of necessary size, if required, 01 no ci af tee, 01 no ci df pipe 1.0 mt long, 02 nos ms df pipe 1.5 mt long, 30 mts ms column pipe flanged type in lenghts of 3.0 mts each, 02 pairs column pipe clamps) 137 pressure & depth gauge (01 no 100 mm dial size pressure gauge feibiq make, 01 no 100 mm dial size depth gauge feibiq make, 01 no control cock for pressure gauge, 35 mts. steel air line with sockets, 01 sets union joints, schraeder valve, hand air pump and gauge board etc.) 138 lifting tackle indef make spur geared lifting tackle of capacity 02 tonnes tested to 03 tonnes with load and hand chain for 4.5 mts lift. 139 special tools and spanners (01 no wooden tool board with l hooks, 01 no hammer with handle, 01 set de spanners consisting of 06 pcs, 02 nos screwdrivers, 01 no 350 mm size pipe wrench, 01 no combination plier) 140 installation of one complete pump set with switchgear material, main piping and valves and do the power wiring work. 141 commissioning of one pumping plant as and when the department arranges the power connection at the site. 142 painting of the switchgear material and delivery pipes and special inside the pump house with 02 coats of enamel paints. 143 testing of the pump at site and the test will be subject to tolerences as provided in the relevant iss. 144 chlorinatorsupply of aquas make electronic chlorinator of 6lph capacity complete accessories and 100 ltr, pvc solution tank. 145 installation charges (1/2 socket fixed in pipe line to provide by the department, 146 street lightsupply and fixing of 7.0 meter long g.i. octogonal pole top dia 70 mm bottom dia 130 mm andbase plate 12 mm thick having3 mm thickness with single arm braclet (1 meter length ) on rcc foundatoion including the cost of foundation ,foundation bolts, excavation & baack filling and required t&p complete fn all respect pwd sor 2018 s.i. no 641 147 supply and fixing of led street light fitting having dia cast aluminium body and diffuser with driverset suitable for 75 to 90 watt. confirming to ip 65 and above protection complete in all respect. pwd sor 2018s.i.no. 1423 cat aaa 148 providing, laying and fixing following dia g.i. pipe (medium class) in ground complete with g.i. fittings including trenching (75 cm deep)and re filling etc as required80 mm dia sor aligarh 2020 149 supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors , hrc fuses, isolatingswitch metering intrument & instrument box with cts etc. in case of tpn, comp;ete in all respect pwd sor 2018 s.i.no. 807 40 a tpn 150 supply and laying of 25mm x 3mm g.i. strip from earth electrode directly in the ground as required complete in all respect. pwd sor 2018 s.i.no. 716 151 supply and burring of safe earthing electrode t 19 (hot dip galvanized), length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal dia 12 mm, outer gi pipe of 16 swg and inner gi pipe of 12 swg with hot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 g.i . strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. pwd sor 2018 s.i.no. 725 (a) 152 solar water heaterspecial system featuresevacuated tube collectorno. pressurized tankgi tank with special passivation coating & magnesium anode to prevent corrosioninner tank with 100 mm puf insulation including cost of gi frame structure, earthing and other required civil work complete all respect as per direction of e/i. 153 solar power system including cost of gi frame structure, earthing and other required civil work complete all respect as per direction of e/i. 154 main lt panel: design, manufacturing, supply installation, testing & commissioning of lt switchgear panels suitable for 433 v, 3 phase, 4 wire, 50 hz power distribution system. the panel shall be indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 swg crca sheet steel, complete with colour coded, heat shrinkable pvc insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. the panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel shall withstand the fault level of 25ka as per single line diagram.a) 1 no. incoming 320a fp 35ka mccb with with o/c, s/c& e/f release, , spreaders & extended roary handle along ct, metering, compelete with all fuses wiring etc and. for 160kva css incomer.b) 1 nos. outgoing 160a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc.c) 1 nos. outgoing 125a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc. c) 8 nos. outgoing 63a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc. 155 emergency cum amf paneldesign, manufacturing, supply installation, testing & commissioning of emergency cum amf panels suitable for 433 v, 3 phase, 4 wire, 50 hz power distribution system. the panel shall be indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 swg crca sheet steel, complete with colour coded, heat shrinkable pvc insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. the panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel shall withstand the fault level of 25ka as per single line diagram. 156 a) 1 no. mains supplyincoming 125a tp 25ka mccb with o/c & s/c release, ct, metering, compelete with all fuses wiring etc.b) 1 no. dg supplyincoming 125a tp 25ka mccb with o/c & s/c release, ct, metering, compelete with all fuses wiring etc. logic control wiring with required relays, timers etc. with trickle/boost battery charger with dc ammeter & voltmeter etc. compelete with all fuses wiring etc and.c) 2 nos. outgoing 100a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc. d) 6 nos. outgoing 63a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc. e) 4 no. outgoing 40a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc. 157 apfc paneldesign, manufacturing, supply installation, testing & commissioning of lt apfc panel as under suitable with incomer bus bar for 433 v, 3 phase, 4 wire, 50 hz power distribution system. the panel shall be indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 swg crca sheet steel, complete coded, heat shrinkable pvc insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. the panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel shall withstand the fault level of 25ka. the panel shall be completed in all respect as per below mentioned boq and.a) 100kvar 10 stage with 160a tp, 25ka mccb incomer with metering &individal mcb/mccb for feeder protection alongwith microprocessor based apfc relay 158 normal floor vertical tpn db (double door)supply installation, testing & commissioning of normal vtpn db suitable for 433 v, 3 phase, 4 wire, 50 hz. the db shall be indoor double door type, sheet metal clad, cubicle, dead front, dust and vermin proof fabricated out of crca sheet steel, complete with colour coded, bus bars and separate earth connection of adequate capacity. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable box/ alley. the db shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel/ db shall withstand the fault level of 10ka as per single line diagram. 159 stilt floor vertical tpn db 4 way (double door) normal supply sor 2018 si no. 1026(c ) +1021+1016a) 1no. incoming 63a (16ka) fp mccbb) 4 nos. outgoing 40a tp mcb (10ka) 160 first &fourth floor vertical tpn db 6 way (double door) normal supply a) 1no. incoming 63a (16ka) fp mccbb) 5 nos. outgoing 40a tp mcb (10ka) si no. 1027 (c )+102+1016 161 second floor vertical tpn db 8 way (double door) normal supplya) 1no. incoming 63a (16ka) fp mccbb) 5 nos. outgoing 40a tp mcb (10ka) si no.1028 © +121+1016+101c) 3 nos. outgoing 32a tp mcb (10ka) 162 third floor vertical tpn db 6 way (double door) normal supplya) 1no. incoming 63a (16ka) fp mccbb) 1 no. outgoing 50a tp mcb (10ka) c) 5 nos. outgoing 40a tp mcb (10ka)si no. 1027 (c )+1021+1017+1016 163 emergency floor vertical tpn db (double door)supply installation, testing & commissioning of emergency vtpn db suitable for 433 v, 3 phase, 4 wire, 50 hz. the db shall be indoor double door type, sheet metal clad, cubicle, dead front, dust and vermin proof fabricated out of crca sheet steel, complete with colour coded, bus bars and separate earth connection of adequate capacity. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable box/ alley. the db shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel/ db shall withstand the fault level of 10ka as per single line diagram. 164 stilt, floor vertical tpn db 4 way (double door) emergency supplya) 1no. incoming 40a (16ka) fp mccbb) 4 nos. outgoing 32a tp mcb (10ka)si no. 1026 (c )+1021+1013 165 first, second, thirdfloor vertical tpn db 8 way (double door) emergency supplya) 1no. incoming 63a (16ka) fp mccbb) 2 nos. outgoing 40a tp mcb (10ka) c) 4 nos. outgoing 32a fp mcb (10ka)si no. 1028 (c )+1021+1016+1013 166 fourth floor vertical tpn db 6 way (double door) emergency supplya) 1no. incoming 40a (16ka) fp mccbb) 5 nos. outgoing 32a tp mcb (10ka)si no. 1027 (c )+1021+1013 167 11kv switch gear (incoming cum outgoing vcb panel)supply of single panel (incoming cum outgoing) set 11kv, 500mva indoor type metal clad floor mounted vermin proof horizontal drawout fully interlocked vertical/horizontal isolation vacuum circuit breaker panel board fabricated out of minimum 2mm thick crca sheet as per specifications. the panel shall be complete with all accessories / fitting / wiring like insulated copper busbar, cable termination boxes suitable for upto 3c x 300 sqmm xlpe armoured, aluminium conductor cable for incoming and outgoing feeder, foundation bolts etc. complete as required and as specified below : incoming cum outgoing : 1 set (each consisting of) 168 one (1) nos. 11kv 630 amps. 500mva, 26.3ka for 3sec. electrically/ manually operated draw out type vacuum circuit breaker complete with trip free spring charged closing mechanism, necessary auxiliary relays, control switches, emergency hand trip devices and mechanical on / off indicator etc. one (1) multifunction meter showing all electrical paramaterie volt, ampere, kw, kva, p.f., kwh etc.one (1) digital type ammeter with 11kv cast resin cts for metering (50/25 /5 5a, cl1, 15va) with ass and 2 amp sp mcb.one (1) voltmeter (0 15kv) with vss.one (1) set of phase indication lamps with 2amp sp mcb for protection (red, yellow and blue).one (1) set of red/ green indicating lamp for close and open position.one (1) no. amber indicating lamp for auto trip.one (1) no. clear indicating lamp for trip circuit healthy. one (1) blue indicating lamp for spring charged.one (1) strip heater to prevent absorption of moisture.one (1) set of 3 o/c + 1e/f (with high set) neumerical relay with 3 nos. 11kv resin cast cts 50/25/5 5a, cl 10p10, 15va.master trip relay.trip circuit supervision relayone (1) no. potential transformer 11kv/v3/110/v3 100va burdenone (1) set of 3element 24v dc aux. relay with h/r flag for tripping of transfomerfault ie. oti, wti & buchholz tripping. one (1) set of 3element 24v dc aux. relay with h/r flag for alarm of transfomerfault ie. oti, wti & buchholz alarm. one (1) set of 8 stage 24v dc annunciator with builtin test/accept/ reset push button along with 24v dc hooter. master trip relay.12 window annunciatorauxiliary switch/relay, master trip, anti pumping relay trip circuit supervision relay and other control relays etc. as per requirements.power pack :one (1) set 230v a.c, / 24v dc, 42ah battery backup, power pack to operate atlease 3nos. operation without ac supply. 169 125 kva 11kv / 0.415kv transformer:design, manufacture, supply, installation, testing and commissioning of 11kv/0.415kv, 125kva transformer with percentage impedance 5% (approx.) (without negative tolerance), 3 phase, 50 hz delta/star connected, outdoor, oil filled, onan type transformer, complete with all fittings such as marhslling box thermometers (oti), wti, buchholz relay, off load tapp changer with + 5 % to –12.5%, tapping at the step of 2.5% bi directional roller, diagrams & rating plate & winding temperature indicator, oil temperature indicator, lifting lugs, h. t. cable box/ lt cable box suitable for termination of cable. transformner shall confirm to latest is : 1180 energy efficiensy level i including making of rcc foundation of size suitable for 125kva transformer.complete in all respect. 170 supply and laying of 3 core standered aluminium conductor xlpe (cross linked polyethylene) insulated pvc bedded, galvanised flat steel strip armoured cables confirming to i.s. 7098 (part ii with latest amendments) ii kv grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. the armouring of cable shall be properly connected with earth conductor by clamps etc. pwd sor 2018 si no. 50670 sq. mm 3 core 171 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required dsr 2018 si no. 10.4.170 sqmm 172 supply of 62.5 kva three phase silent dg set comprising of cummins make engine model 4btaa3.3 g11 developing 84 bhp and 62.5 kva, 415 v stamford make alternator mounted on a common base, complete with fuel tank, batteries and leads, residential silencer, standard panel, first fill of lube oil, avm pads, acoustic enclosure 173 amf panel suitable for 62.5 kva dg set 174 pcc foundation mixing ratio 1:2:4 cement, morang, concrete suitable size of dg set 175 gi pipe chemical earthing 50x3000mm complete with back filled compound 176 installation: like unloading & shifting at site, cable aluminium 70x3.5 c 20 meter, control wiring for amf panel, end termination of cabletesting, commissioning withdiesel. ...

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

32586856 adding 1 no. 132 kv d / c ( b+5 ) type tower on 132 kv s / c shamli jhinjhana line in between tower loc. no. 28 & 30 by dismantling existing tower loc. 29, under etd, shamli 2 supply of hot dip galvanized hexagonal head bolts, nuts and washer for above structure as per bom. 3 accessories for tower: 4 number plate 5 danger plate 6 phase plate 7 earthing set 8 accessories for conductor: 9 vibration damper 10 single tension fitting for acsr panther conductor 11 ms compression joint 12 repair sleeve 13 accessories for earth wire suitable for 7 / 10 swg: 14 tension clamp 15 copper bond 16 vibration damper 17 schedule q 2 ( work ) 18 survey including preparation of schedule of materials, marking of location ( route length ) , gps survey of line with co ordinates of each tower 19 survey & check survey & peg marking 20 cost of excavation of 132 kv tower foundation pits including all earth work back filling, watering and leveling for 132 kvdc ( b+5 ) 01 no. 21 setting ofstubs including all foundation work but excluding the cost of concreting and excavation ( rate per location ) for 132 kv 132 kvdc ( b+5 ) 01 no. 22 cost of concreting for following towerfoundation including cost of cement, coarse sand, stone grid, dewatering, shoring and shuttering, forming, curing but excluding cost of reinforcement bars with 1:2:4 mix concrete.132 kvdc ( b+5 ) 01 no. 23 installation of steel reinforcement bars in rcc foundation including cost of cutting, welding, binding and placing them in foundation pits132 kvdc ( b+5 ) 01 no. 24 dismantling of existing tower loc no. 29 ( a+0 ) including excavation of old foundation with stub and all other works to complete the job satisfactory. 25 carriage of new material from store to site and shifting of dismantled towers from the working site to the s / s store as per the instruction of the supervising engineer. 26 erection of superstructure of 132 kv tower and their extensions wherever required including all work above ground level excluding hoisting of insulator hardware& accessories, but including fitting of danger, number, phase plate, and fixing & punching. 132 kvdc ( b+5 ) 01 no. 27 tack welding of all the bolts upto the height of second section of the tower from ground level with three tacks of 10 mm / 12mm electrode and application of zinc rich paint on the affected surface including cost of materials for 132 kvdc ( b+5 ) 01 no. 28 de stringing of old panther conductor including de hoisting of all the necessary hardwares and accessories between section to suspension tower. ( from loc. 25 to 30 ) 29 laying, stringing of acsr panther conductor including hoisting of insulators, fitting of all necessary hardware and accessories i.e. fittings, vibration dampers etc on all phase. ( from loc. 25 to 30 ) 30 destringing of earthwire between from loc. 25 to 30. 31 stringing of earthwire between suspension to suspension tower. 32 earthing work including all earth work etc. for pipe type earthing including cost of coal and salt except earthing pipe....

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

32299690 for the supply of opgw for lilo of 132 kv pratap vihar dph line andwork of dismantling of earthwire & installation of opgw along with hardware and accessories etcin live line condition for lilo of 132 kv pratap vihar dph line at 132 kv bsr ii s / s under etd ii ghaziabad...

Uttar Pradesh Housing And Development Board - Uttar Pradesh

32092032 electrical / mechanical work at 100 bedded hospital gramsabha shivshat raniganj distt. pratapgarh 1 internal electrification workwiring point for light with 1.5 sq. mm.frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sqmm frlsh pvc insulated multistrand copper conductor cable as earth wire drawn inside the conduit with gp box, modular type switch & ceiling rose / angle / batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. pwd sor 2018 si no 138 ( c ) +187 ( a ) 2 wiring point for two way light with 1.5 sq. mm. frls pvc insulated multistrand single core copper conductor cable in heavy guage pvc conduit. pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 1.5 sq. mm. frlsh pvc insulated multistrand copperconductor cable as earthwire drawn inside the conduit, gp box and 2no. two way modular type switches and ceiling rose / angle / batten holder on 3 mm. thick phenolic laminated backlite sheet etc. complete in all respects, as directed including matching colour wash.pwd sor 2018 si no 139 ( c ) + 187 ( b ) 3 wiring point for fan / fresh air fan ( light duty exhaust fan ) with 1.5 sq.mm.frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm.frlsh pvc insulated multistrand copper conductor cable as earth wiredrawn inside the conduit withmodular type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. pwd sor 2018 sl no 140 ( c ) + 187 ( a ) 4 wiring point for call bell with 1.5 sq. mm. frls pvc insulated multistrand single core copper conductor cable in heavy guage pvc conduit. pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 1.5 frlsh pvc insulated multistrand copperconductor cable as earthwire drawn inside the conduit, gp box and modular type bell push or 2 pin shocket etc complete in all respects, as directed including matching colour wash. pwd sor 2018 si no 142 ( c ) + 187 ( e ) 5 wiring point for plug with 1.5 sq. mm.frlsh pvc insulated multistrand copper onductor cable in pvc conduitpartly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm.frlsh pvc insulated multistrand copper conductor cable as earth wiredrawn inside the conduit and modular type switch and socket etc., complete in all respect including matching colour wash.pwd sor 2018 sl no 141 ( c ) + 187 ( a ) 6 supply and wiring of submain with two number 2.5 sq.mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 20 mm dia heavy duty ( 2mm thick ) pvc conduit partly laid in slab alongwith the reinforcement before concreting and partly concealed in wall with 1 nos. 1.5 sq. mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. including matching colour wash. pwd sor 2018 sl no 1307 ( c ) 7 supply and wiring of submain with two number 4 sq.mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 20 mm dia heavy duty ( 2 mm thick ) pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with one no. 2.5 sq. mm. frlsh pvc insulated multistrand copper conductor cable as earth continuity wire drawn in conduit including matching colour wash etc. complete in all respect. pwd sor 2018 sl no 221 ( c ) 8 supply and wiring of sub main with two number 6.0 sq.mm frlsh pvc insulated 1100 v grade multstrand single core copper conductor cable in 20 mm dia heavy duty ( 2mm thick ) pvc conduit partly concealed in wall and partly laid in slab along with reinforcement before concretiing with 1 no. 4.0 sq.mm. frlsh pvc insulated multstrand copper conductor cable as earth continuity wire drawn iin conduit including matching colour wash. complete in all respect pwd sor 2018 si no 222 ( c ) 9 supply and wiring of 4 number 6 sq. mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 32 mm dia heavy duty ( 2mm thick ) pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with 2 nos 4 sq.mm. frlsh pvc insulated copper conductor cable as earth continuity wire drawn in conduitincluding matching colour wash etc. complete in all respect..pwd sor 2018 sl no 278 ( c ) 10 supply and wiring of 4 number 10 sq. mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 32 mm dia heavy duty ( 2mm thick ) pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with 2 nos 6 sq.mm. frlsh pvc insulated copper conductor cable as earth continuity wire drawn in conduitincluding matching colour wash etc. complete in all respect..pwd sor 2018 sl no 278 ( c ) 11 supply and wiring of sub main with 4 number 16.0 sq.mm frlshpvc insulated 1100 v grade multstrand single core copper conductor cable in 40mm dia pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with two number 10 sq.mm. rlsh pvc insulated copper conductor cable as earth continuity wire drawn in conduitincluding matching colour wash etc. complete in all respect. pwd sor 2018 si no 279 ( c ) 12 supply and fixing hexagonal / round g.p. fan box of approved make made up of 1.0 mm thick isi marked g.p. sheet spot welded four to eight holes of 25.4 mm for pipe entry of the box. holes should be semi shuttered type with 0.5 mm g.p. sheet made upper & lower cover duly screwed fitted with 300 mm round zink coated m.s bar x 12 mm & brand name should be embossed. fixing with wiring conduit laid in the r.c.c. roof before concreting along with supply of all material, labor, t&p etc. required for proper completion of the work .pwd sor 2018 s.i.no. 1149 13 supply and fixing of led tube light with metal heavy duty box type batten light fitting 1 x 22 watt suitable for upto 1x22 watt led polycarbonate tube light complete including tube suitabe for both surface & suspended complete in all respect. 2420 system lumens, 110lm / watt pf>0.95, thd<10% cri>80, sheet thicknes 0.8mm, tube with aluminium heat with 5 year warrantee. pwd sor 2018 sl no 1434 cat aaa 14 supply and fixing of recess / surface mounting round 18 watt to 20 watt cut out min 150 mm height min 40 mm, led down lighter having powder coated die cast aluminium housing with heat sink diffuser / reflector and driver set suitable for 24 hr continuous operation, compelete in all respect. pwd sor 1980 2200 system lumens, 110lm / watt pf>0.95, thd<10% at full load, cri>80, with 5 year warrantee. si no. 1403 15 supply and fixing of water tight oblong 10 watt led bulkhead luminaire with driver set confirming to ip 65 and above protection . complete in all respect. si no. 1417 cat aaa 16 supply and fixing of 36 watt to 46 watt indoor recess mounting led square fitting for armstrong ceiling having powder coated die cast aluminium housing body with extended heat sink and diffuser of special polycarbonate meterial and driver set complete in all respect.pwd sor 2018 s.i.no. 1406 cat a 17 making hole in the wall for exhaust fan and finishingproperly complete in allrespect.pwd sor 2018 s.i.no. 1121 18 supply and erection of 300 mm sweep ac 230 / 250 volts, 50 hz exhast fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required connection etc. complete as required mr 19 supply and erection of 400 mm sweep ac 230 / 250 volts, 50 hz wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required connection etc. complete as requiredmr 20 supply and fixing of electronic fan regulator ( modular ) 120 280 v. isi marked, on the existing switch board including making connections, required material, labour t&p etc. for proper completion of work to the satisfaction of engineer in charge of work. pwd sor 2018 s.i.no. 1203 ( c ) 21 supply and erection of ceiling fan with motor of ac permanent insulation, capacitor rating conforming bee 5 star rating and is:374 / 79 and also comply with is: 1709 / 1984 with latest amendment. the rated voltage 220 / 240 volts, 50hz 1 ph ac the fan assemble should consists of down rod, blades, shackle, canopies etc and with double ball bearing system .pwd sor 2018 si no 1501+ 1115 bee 5 star rated 1200 mm sweep 22 s / f of 3mm thick bakelite sheet cover round / hexagonal type for fan box complete with all material, labour t&p as per direction of e / i. 23 s / f of 3mm thickal. sheet junction box cover complete in all material labour t&p as per direction of e / i. 24 supply and fixing of surface / flush mounting 8 way tpn distribution board with additional metal door without mcb complete in all respect and directed at site by e / i. pwd sor 2018 si no 1027 ( a ) cat a 25 s&f of 6 amp to 32 amp. spmcb ( 10 ka ) c curve pwd sor 2018 si no 1002 cat a 26 s&f of 63 amp. 4 polespmcb ( 10 ka ) c curve pwd sor 2018 si no 1007 27 supply and fixing of power plug with 20 amp. / 250 voltflush type modular switch and 5 pin 20 a / 250 volt flush type universal modular socketswitch on concealed m.s boxincluding supply of all material, labour t&p etc. required for proper completion of work. pwd sor 2018 si no 1139 ( a ) 28 s & f sheet steel enclosure surface / flush mounting fitted with 30amp. 2pin and earth metal clad scraping earth plug and socket complete in all respect. as directed at site byengineer in charge.1031 ( a ) 29 supply and burring of safe earthing electrode t 39 zn zinc coated, length 3000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal dia 12mm, coating 80 100 micron filled with crystalline conductive mixture ( ccm ) having anti corrosive & conductive property with 50 kgs activated soil ( bfc ) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square c.i. frame with hinged cover & masonry housing. ( from electrode terminal to switch board, cost of 25 x 3 g.i. strip will be extra make: as approved in u.p. p.w.d., & c.p.r.i. certified pwd sor 2018 si no 726 ( d ) 30 supply and laying of 25 mm x 3 mm g.i srtip form earth electrode directly in the ground as required complete in all respects. pwd sor 2018 si no 716 31 providing, laying and fixing 100mm dia g.i. pipe ( medium class ) in ground complete with g.i. fittings including trenching ( 75 cm deep ) and re filling etc as required. dsr 2018 si no 14.13.3 32 supplyandlayingof aluminiumconductorpvcinsulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. pwd sor 2018 si no 501 33 10 sq mm 4 core 34 16 sq mm 4 core 35 70 sq mm 3.5 core 36 95 sq mm 3.5 core 37 240 sq mm 3.5 core 38 300 sq mm3.5 core 39 supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. the armouring ofthe cable shall be properly connected with the earth as per direction of engineer incharge.pwd sor 2018 si no 503 40 10 sq mm 4 core 41 16 sq mm 4 core 42 70 sq mm 3.5 core 43 95 sq mm 3.5 core 44 240 sq mm 3.5 core 45 300 sq mm3.5 core 46 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the engineer incharge.pwd sor 2018 si no 504 47 10 sq mm 48 16 sq mm 49 35 sq mm 50 50 sq mm 51 70 sq mm 52 95 sq mm 53 120 sq mm 54 240 sq mm 55 300 sq mm 56 supply and fixing of call bell of approved make on polished mdfeg / teak ply board including making connections etc. complete in all respect. pwd sor 2018 si no 1101 57 supply of franklin france make advanced piezoelectric exciter device based lighting protection system suitable for protection of building against direct lightning strike complete with ealy streamer emission with piwezoelectric device for corona effect ) stainlles steel lighting conductor air terminal with event counter with sensitivity 1 ka to 100 ka for 8.20 micro second impulse for 1 ka control over the release of ions positive or negative without additional power supplies requirement required complianece with ip53 enclosures ) 58 saint elmo lightening conductor with discharge counter ( sensitivity 1 ka, 8 / 20 microsecound with ip 53 enclosures ) 59 elevation rod : 2m. afc2001 two elevation rods for are required for mounting a one lightening conductor mr 60 installation of franklin france make external lightening protection system. 61 ssupply and fixing of vertical down conductor of 32mm x 6mm g.i. strip etc. on approved clamps on surface for lightning conductor complete in all respects ( for two storeyed buildings ) .p.w.d.s.o.r. 2018 s.i. no.713 ( c ) 62 supply and fixing of testing joint of g.i. strip 32mm x 6mm and 150mm long with g.i. bolts and nut etc. complete in all respect.p.w.d.s.o.r. 2018 s.i. no.719 63 supplying and fixing following modular switch / socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. telephone socket outlet dsr no 1.24.6 64 supply and fixing of g.p. modular switch box for 1 / 2 module of approved make made up of 1.0 mm thick isi marked g.p.sheet including adjestable nakka and holes plugged with pvc nylon caps . two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box. holes should be semi shuttered type and fitted with heavy brass earth piller duly screwed & brand name should be embossed. box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s / o all materials, labour and t&p required for proper completion of work as directed at site by the engineer in charge. p.w.d.s.o.r. 2018 s.i. no.1152 ( a ) 65 1 or 2 module ( 75mm x 75 mm ) 66 supplying and drawing telephone wire following pair 0.5 sqmm fr pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel / pvc conduit as required. dsr no 1.18.2 67 2 pair 68 supply and fixing and concealing of 20 mm dia. 2mm thick pvc conduit pipe with isi mark embossed and with pvc accessories confirming to is no. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and t&p etc required for proper completion of the work as per directions and to the satisfaction of engineer in charge. sor 2018 si no. 148 ( a ) 69 supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality sor 2018 si no. 1136 70 s & f sheet steel enclosure for t.p. / four pole mcb. sor 2018 si no. 1033 71 s&f of 63 amp. 4 pole mcb ( 10 ka ) c curve sor 2018 si no. 1020 ( a ) cat aaa 72 fire fighting systemproviding, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 3589 / is 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall / ceiling with suitable clamp / support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : dsr & aor 2019 si no 7 73 200 mm dia 74 150 mm dia 75 100 mm dia 76 80 mm dia 77 65mm dia 78 50mm dia 79 40mm dia 80 32mm dia 81 25 mm dia 82 providing laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239 / 3589 i / c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar / asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required. dsr & aor 2019 83 200 mm dia si no 6.1 84 150 mm dia si no 6.2 85 supplying, fixing, testing and commissioning of manual swing typehose reel is:444 complete with heavy duty reel, 20 mm dia. x 30 mtr long, pvc pressure hose pipe , red coloured, ss jet nozzel, 25mm. isolating valve and all other neccessary fixing accesories complete in all respect. dsr no 17:1 86 supplying and fixing single headed internal hydrant valve with instantaneous gunmetal / stainless steel coupling of 63 mm dia with cast iron wheel isi marked conforming to is 5290 ( type a ) with blank gunmetal / stainless steel cap and chain as required :as per dsr & aor 2019 s.i. no. 9.1 87 supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to is 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : dsr & aor 2019si no. 18.1 88 supplying and fixing 63 mm dia, 15 m long rrl hose pipe with 63 mm dia male and female couplings duly bound with gi wire, rivets etc. conforming to is 636 ( type a ) as required : dsr & aor 2019 si.no.16.1 89 providing and fixinghose box ( 600x300x200 ) size of suitable size made out of 16 / 18 swg thick having central opening and 4 mm thick glazed glass double door including necessory rubber beading key pocket, handle locking arrengment painting with polyurethene based red paint etc. the words fire hose to be painted on the dooor as per approved drawing complete in all respect. mr 90 supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia ms pipe connection conforming to is 904 as required : 91 2 way 100 mm dia m.s. pipe si no. 19.1 92 supply, fixing, testing and commissioning of 25mm ball valve complete. mr 93 supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. dsr & aor 2019 si no. 20 94 supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: ( terrace pump ) ( a ) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to is : 1520 ( b ) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase, 50 hz, ac supply with ip55 class of protection for enclosure, horiziontal foot mounted type with class f insulation, conforming to is 325. ( c ) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. ( d ) suitable cement concrete foundation duly plastered and with anti vibration pads.supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.1620 lpm at 70 m head dsr & aor2019 si no. 1.8 95 supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : ( diesel driven pump ) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 / 24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.make : kirloskar / other standard make.dsr no. 2.81620 lpm at 70 m head 96 supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : ( jockey pump ) a ) horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.b ) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is : 325.c ) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads. make kirloskar / other standard make dsr no. 3.2180 lpm at 70 m head 97 automatic control panel ( s ) fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable / solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required : incoming 250a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0 500v with selector switchdigital ammeter ( 0 250 a ) with selector swtich & cts etc.outgoing main fire pump : 125 a 50ka tpn mccbjockey pump : 63 a , 50ka tpn mccb, diesel engin control complete in all respect dsr no. 5.1 98 providing & fixing of pressure switch in m.s. pipe line including connection etc. as required. dsr & aor 2019 si no. 22 99 providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required dsr 2018 si no. 16.8 100 sitc of foot valves with strainer at the suction pipe of fire pumps ( in case of negative suction only ) . make kalpana / kartarsir / advance or equivalent 101 150mm dia 102 100mm dia 103 supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze / gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required : dsr & aor 2019 si no 11 104 150 mm dia 105 100 mm dia 106 80 mm dia 107 providing, installation, testing and commissioning of non return valve of following sizes confirming to is: 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required : dsr & aor2019 si no. 14 108 150 mm dia 109 100 mm dia 110 supply and fixingof c02 type fire extinguisher 4.5 kg. capacity ( isi marked is : 2878 & tac approved ) complete with initial charge and wall bracket, along with supply of all materials and labourfor proper completionof work.pwd sor 2018 si no 1132 111 supply and fixingof fire extinguisher, abc type 6.00 kg. capacity ( isi marked is : 15683 & tac approved ) complete with initial charge and wall bracket, along with supply of all materials and labourfor proper completionof work.pwd sor 2018 si no 1131 ( a ) 112 supply and fixing of self glow type exit sinage. 113 sitc ofsprinkler 68° deg, complete in all respects. ( make: omex / life guard / safex ) dsr 2019 si no. 21.1pendent type 114 fire alarm systemworksupplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices ( including detectors ) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics / lcd display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory ( eprom ) , power supply unit ( 230± 5% v, 50 hz ) , 48 hrs back up with 24 volt sealed maintenance free batteries with automatic charger. the panel shall have facility to connect printer to printout log and facility to have seamless integration with analog / digital voice evacuation system ( which is part of the schedule of work under sh: pa system ) and shall be complete with all accessories . the panel shall be compatible for ibms system with open protocol bacnet / modbus over ip complete as per specifications. dsr 2018 si no 17.2.1.1 115 ten loop panel. 116 supplying, installation, testing & commissioning of intelligent analog addressable photo thermal detector complete with mounting base complete as required. dsr 2018 si no 17.2.4 117 supplying, installation, testing & commissioning of response indicator on surface / recessed ms box having two led, metallic cover complete with all connections etc as required.dsr 2018 si no 17.2.5 118 supplying, installation, testing & commissioning of addressable phone control module complete as required. dsr 2018 si no 17.2.11 makeinnel / simplex / tyco 119 supplying, installation, testing & commissioning of addressable manual call point complete as required. dsr 2018 si no 17.2.14 120 supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. dsr 2018 si no 17.2.15 121 supplying, installation, testing & commissioning of addressable fire control module complete as required. dsr 2018 si no 17.2.10 122 supplying, installation, testing & commissioning of faultisolator complete with base as required. dsr 2018 si no 17.2.7 123 supplying, installation, testing & commissioning of repeater panel wih 320 character / touch screen lcd display with inbuilt reset ackowledge and silence switches complete as required.dsr 2018 si no 17.2.3 124 supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600 / 1000v rated with annealed copper conductor having xlpe insulation, steel wire armouring & frls outer sheath complete as required.. dsr 2018 si no. 17.5.2 125 supplyandlayingof aluminiumconductorpvcinsulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. pwd sor 2018 si no 501 126 150 sqmm 3.5 core 127 supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. the armouring ofthe cable shall be properly connected with the earth as per direction of engineer incharge.pwd sor 2018 si no 503 128 150 sqmm 3.5 core 129 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the engineer incharge.pwd sor 2018 si no 504 130 70 sq mm 131 150 sqmm 132 supplying, installation, testing & commissioning of 6 zone, voice alarm controller with usb, mp3 player ( including 6 zonebutton paging station ) with seamless integration facility withmain fire alarm panel for voice evacuation complete asrequired dsr 2018 si.no.17.3.1 133 supplying, installation, testing & commissioning of 1.5 / 3 / 6w metal box ceiling / wall speakers complete as required.dsr 2018 si.no.17.3.3 134 supplying, installation, testing & commissioning of digital audio amplifier 50 watt, 25v rms operating at 240 volt ac supply complete as required.dsr 2018 si.no.17.3.6 135 supplying, installation, testing & commissioning of voice command keypad 6 zone, with microphone assembly complete as required.dsr 2018 si.no.17.3.9 136 street light worksupply and fixing of 7.0 meter long g.i. octogonal pole top dia 70 mm bottom dia 130 mm andbase plate 12 mm thick having3 mm thickness with single arm braclet ( 1 meter length ) on rcc foundatoion including the cost of foundation , foundation bolts, excavation & baack filling and required t&p complete fn all respect pwd sor 2018 s.i. no 641 137 supply and fixing of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 watt. confirming to ip 66 protection complete in all respect pwd sor 2018s.i.no. 1424 cat aaa 138 providing, laying and fixing following dia g.i. pipe ( medium class ) in ground complete with g.i. fittings including trenching ( 75 cm deep ) and re filling etc as required dsr 2018 si no. 14.13.3 139 100 mm dia 140 supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors , hrc fuses, isolatingswitch metering intrument & instrument box with cts etc. in case of tpn, comp;ete in all respect pwd sor 2018 s.i.no. 807 141 40 a tpn 142 supply and laying of 25mm x 3mm g.i. strip from earth electrode directly in the ground as required complete in all respect. pwd sor 2018 s.i.no. 716 143 supply and burring of safe earthing electrode t 19 ( hot dip galvanized ) , length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal dia 12 mm, outer gi pipe of 16 swg and inner gi pipe of 12 swg with hot dip galvanization up to 100 micron filled with crystalline conductive mixture ( ccm ) having anti corrosive & conductive property with 50 kgs activated soil ( bfc ) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonry husing ( from electrode terminal to switch board, cost of 25 x 3 g.i . strip will be extra ) make: as approved in u.p. p.w.d., & c.p.r.i. certified. pwd sor 2018 s.i.no. 725 ( a ) 144 tubewell workboring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in is: 2800 ( part i ) , including collecting samples from different strata, preparing and submitting strata chart! bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90 metre depth below ground level. dsr 2019 sino. 23.1.1 145 350 mm dia upto 60 msino. 23.1.1.2 146 60 90 msi no. 23.1.1.1 147 90 150 msi no. 23.2.1.2 148 150 220 msi no. 23.2.1.2 149 220 300 m 150 supplying, assembling, lowering and fixing in vertical position in bore well, erw ( electric resistance welded ) fe 410 mild steel screwed and socketed / plain ended casing pipes of required dia, conforming to is: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of engineer in charge. dsr 2019 si no. 23.10 151 150 mm nominal size dia having minimum wall thickness 5.00 mm si no. 23.10.2 152 200 mm nominal size dia having minimum wall thickness 5.40 mm si no. 23.10.3 153 supplying, assembling, lowering and fixing in vertical position in bore well, erw ( electric resistance welded ) fe 410 plain slotted ( having slot of size 1.6 / 3.2 mm ) mild steel threaded and socketed / plain bevel ended pipe ( type a ) of required dia, conforming to is: 8110, of reputed and approved make, having wall thickness not less than 5.40 mru, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fitting & accessories, all complete, for all depths, as per direction of engineer in charge. dsr 2019 si no. 23.11 154 150 mm nominal size dia si no. 23.11.2 155 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assemblv of tube well as oer is:2800 ( dart n.dsr 2019 si no. 23.15 156 150 mm dia si no. 23.15.2 157 providing and fixing m.s. clamp of required dia to the top of casing! housing pipe of tube well as per is: 2800 ( part i ) , including necessary bolts & nuts of required size complete. dsr 2019 si no. 23.14 158 200 mm clamp si no. 23.14.3 159 supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. dsr 2019 si no. 23.6 160 development of tube well in accordance with is : 2800 ( part 1 ) and is: 11189, to establish maximum rate of usable water yield without sand content ( beyond permissible limit ) , with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by v notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, ilc disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of engineer in charge dsr 2019 si no. 23.12 161 providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing! casing pipe, rmovable as per requirement, all complete for borewell of: dsr 2019 si no. 23.13 162 200 mm dia si no. 23.13.3 163 500 lpm 52 m head of k s b make submersible pumping plant 164 submersible pump set. 165 switch gear 166 main piping and valves 167 pressure & depth gauge 168 lifting tackle 169 installation 170 commissioning 171 painting 172 testing 173 supply of aquas make electronic chlorinator of 6lph capacity complete accessories and 100 ltr, pvc solution tank. 174 installation charges ( 1 / 2 socket fixed in pipe line to provide by the department, 175 sitc of 20 passenger stretcher lift 2 stop, 2 opening at same side with ss hairline finish fully automatic gate with side opening along with acv3 controller and gearless machine no. of lift speed 1.0 m / sload 1360 kgcapacity 20 passengerfloor g + 1car travel 7000 mmhoist way dimension 2400mm wide x 2800mm deep ( required ) overgead 4500 mmpit depth 1500 mmcar dimension 1300mm wide x 2400mm deep x 2200mm highdoor opening 1000mm wide x 2000mm highelectric supply 415 volts, 3 phase, 50hz, ac 176 main lt paneldesign, manufacturing, supply installation, testing & commissioning of lt switchgear panels suitable for 433 v, 3 phase, 4 wire, 50 hz power distribution system. the panel shall be indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 swg crca sheet steel, complete with colour coded, heat shrinkable pvc insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley / chamber. the panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel shall withstand the fault level of 25ka.a ) 1 no. incoming 1250a fp 50ka manually operated drawout type acb with numerical o / c, s / c& e / f release, ct, metering, compelete with all fuses wiring etc and as per sld. for 630kva css incomerb ) 1 no. outgoing 630a 35ka tp mccb with extended rhom along with o / c & s / c protection along with ammeter with ammeter selector switch, ct etc. c ) 1 no. outgoing 400a 35ka tp mccb d ) 3 nos. outgoing 250a 25ka tp mccb e ) 4 nos. outgoing 200a 25ka tp mccb f ) 4 nos. outgoing 160a 25ka tp mccb g ) 1 no. outgoing 125a 25ka tp mccb h ) 2 nos. outgoing 100a 25ka tp mccb i ) 3 nos. outgoing 63a 25ka tp mccb 177 normal floor panels supply installation, testing & commissioning of normal floor panels suitable for 433 v, 3 phase, 4 wire, 50 hz. the panel / dbshall be indoor, sheet metal clad, cubicle, dead front, dust and vermin prooffabricated out of crca sheet steel, complete with colour coded, bus bars and separate earth connection of adequate capacity. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable box / alley. the panel / dbshall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panelshall withstand the fault level of 10ka. 178 ground floor panel ( wing a ) normal supplya ) 1no. incoming 160a ( 16ka ) fp mccb with standard incomer metering b ) 7 nos. outgoing 63a fp mcb ( 10ka ) 179 ground floor panel ( wing b ) normal supplya ) 1no. incoming 200a ( 16ka ) fp mccb with standard incomer meteringb ) 2 nos. outgoing 63a tp mccb ( 16ka ) b ) 6 nos. outgoing 63a fp mcb ( 10ka ) 180 ground floor panel ( wing c ) normal supplya ) 1no. incoming 250a ( 16ka ) fp mccb with standard incomer meteringb ) 1 nos. outgoing 100a tp mccb ( 16ka ) c ) 6 nos. outgoing 63a fp mcb ( 10ka ) 181 first floor panel ( wing a ) normal supplya ) 1no. incoming 160a ( 16ka ) fp mccb with standard incomer meteringb ) 7 nos. outgoing 63a fp mcb ( 10ka ) 182 first floor panel ( wing b ) normal supplya ) 1no. incoming 160a ( 16ka ) fp mccb with standard incomer meteringb ) 7 nos. outgoing 63a fp mcb ( 10ka ) 183 first floor panel ( wing c ) normal supplya ) 1no. incoming 200a ( 16ka ) fp mccb with standard incomer meteringb ) 2 nos. outgoing 63a tp mccb ( 16ka ) c ) 6 nos. outgoing 63a fp mcb ( 10ka ) 184 emergency floor panelsdesign, manufacturing, supply installation, testing & commissioning of emergency floor panels / vtpn db suitable for 433 v, 3 phase, 4 wire, 50 hz. the panel / dbshall be indoor, sheet metal clad, cubicle, dead front, dust and vermin prooffabricated out of crca sheet steel, complete with colour coded, bus bars and separate earth connection of adequate capacity. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable box / alley. the panel / dbshall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel / dbshall withstand the fault level of 10ka 185 ground floor panel ( wing a ) & ( wing b ) emergency supplya ) 1no. incoming 100a ( 16ka ) fp mccb with standard incomer meteringb ) 7 nos. outgoing 40a fp mcb ( 10ka ) 186 ground floor panel ( wing c ) emergency supplya ) 1no. incoming 125a ( 16ka ) fp mccb with standard incomer meteringb ) 1nos. outgoing 63a tp mccb ( 16ka ) c ) 6 nos. outgoing 40a fp mcb ( 10ka ) 187 first floor panel ( wing a ) emergency supplya ) 1no. incoming 125a ( 16ka ) fp mccb with standard incomer meteringb ) 1 nos. outgoing 63a tp mcb ( 10ka ) c ) 6 nos. outgoing 40a fp mcb ( 10ka ) 188 first floor panel ( wing b ) & ( wing c ) emergency supplya ) 1no. incoming 160a ( 16ka ) fp mccb with standard incomer meteringb ) 2 nos. outgoing 63a tp mccb ( 16ka ) b ) 7 nos. outgoing 40a fp mcb ( 10ka ) ...

Bharat Heavy Electricals Limited - Uttar Pradesh

31390817 supply of clamps and connectors for phpa bhutan punatsangchhu 1 hydroelectric project supply of clamps and connectors for phpa bhutan punatsangchhu 1 hydroelectric project , supply clamps & connectors : 400kv, 50ka for 1s, 2000a, isolator ( hdb ) connector suitable for twin moose , supply clamps & connectors : 400kv, 50ka for 1s, 2000a, ct connector suitable for twin moose , supply clamps & connectors : 400kv, 50ka for 1s, cvt connector suitable for twin moose , supply clamps & connectors : 400kv, 50ka for 1s, la connector suitable for twin moose , supply clamps & connectors : 400kv, 50ka for 1s, 2000a, wt connector suitable for twin moose , supply clamps & connectors : 400kv bpi connector suitable for twin moose , supply clamps & connectors : 400kv, cable sealing end connector suitable for twin moose , supply clamps & connectors : 400kv, cable sealing end connector suitable for al tube 4 inch ips, rigid type , supply clamps & connectors : 400kv, tee connector suitable for twin moose to twin moose , supply clamps & connectors : 400kv, flexible spacer suitable for twin moose , supply clamps & connectors : 400kv, pg clamp suitable for single moose to single moose , supply clamps & connectors : 220kv, 40ka for 1s, cvt connector suitable for single moose , supply clamps & connectors : 220kv, 40ka for 1s, la connector suitable for single moose , supply clamps & connectors : 220kv, 40ka for 1s, 1250a, wt connector suitable for single moose , supply clamps & connectors : 220kv, gis bushing connector suitable for single moose , supply clamps & connectors : 220kv, gib bushing connector suitable for single moose , supply clamps & connectors : 220kv bpi connector suitable for single moose , supply clamps & connectors : 220kv, tee connector suitable for single moose to single moose , supply clamps & connectors : 220kv, tee connector suitable for single zebra to single conductor as per ts , supply clamps & connectors : 220kv, pg clamp suitable for single moose to single moose , supply clamps & connectors : strain / tension clamps ( bolted type ) for earthwire with d shackle assembly , clamps & connectors pg clamp for shield wires of dia 10.98mm , clamps & connectors clamp for 10.98mm dia shield wire on lattice / pipe structure , clamps & connectors clamps for 75x12mm earthing strip on lattice / pipe structure , clamps & connectors pad connector to suit 10.98mm dia gs wire and 75x12 mm gs flat...

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

30933861 annual maintenance of 132 kv lines under etsd i sardhana under etd ii meerut. 1 regular tower to tower ground & tower top patrolling of following 132 kv lines as detailed below. patrolling work consist of detection of the defects like missing / theft tower members, hot point, punctured / flashed over disc insulator / polymer string, dislocation of vibration dampers, damaged conductor / earthwire, checking of foundation / stubs, position of earthing & position of trees in 27 meter wide line corridor. patrolling shall be done regularly on quaterely basis i.e. 4 time in a year with petrolling report on specific upptcl performa in 3 copies. 2 132 kv s / c linei. 132 kv modipuram kankarkhera ii line single circuit section 11.80 km.ii. 132 kv modipuram sardhana line single circuit section 05.30 km.iii. 132 kv modipuram kapsad s / c line till lilo point 16.00 km.iv. 132 kv sardhana m / s daurala sugar mill co gen s / c line 10.02 km.total 43.12 km x 4= 172.48 km. 3 132 kv d / c linei. common section of 132 kv modipuram sardhana line and 132 kv modipuram kankarkhera ii line. 09.50 km.ii. lilo section of 132 kv modipuram kapsad line and 132 kv khatauli kapsad line. 05.70 km.total – 15.20 km. x 4= 60.80 km. 4 emergency patrolling includes tower top petrolling of 132 kv lines in the event of tripping / break down to find out fault location and type of fault. 43.12 km. +15.20 km. =58.32 km. x 2= 116.64 km. 5 opening / cutting of nut & bolts of remaining cut pieces of tower members stolen by miscreants to be opened safely / cut safely with the help of gas cutter / hacksaw blade. fabrication & fixing of tower members including cartage of steel angles from sub station store, punching holes for proper placement tightening of nuts & bolts punching & chamfering at different tower location of above transmission line and associated work to complete the job satisfactorily as per technical specification. 6 strengthening / replacement of damaged jumpers at tension towers. 7 tightening of jumpers at tension towers on both sides. 8 replacement of damaged / punctured disc insulator / polymer insulator string including cartage of material from store to work site and back to store of theabove line: 9 for suspension string 10 for tension string 11 lopping, chopping and cutting of trees branches in the 27 meter corridor of above line and stacking of above cuttings at proper place far from the line. 12 removal of bird nest from cross arm / peak / cage / body of tension / suspension towers 13 from cross arm of tension / suspension tower with manual checking and cleaning of porcelain disc / composite polymer insulator string. 14 from peak / cage / body of tension / suspension tower. 15 repairing of damaged acsr panther conductor by fixing one no. repair sleeve / mid span joint including lowering down of conductor ( up to 01 km ) and restringing of the same with all associated work to complete the job satisfactorily. 16 attending breakdown of broken panther conductor by fixing mid span compression joints including lowering down of conductor restringing of the same up to 01 km including replacement of conductor, insulator string, fitting, jumper and associated work as required. 17 repairing of conductor by providing repairing sleeve / mid span joint when conductor down to earth during attending breakdown of conductor as mentioned in item no. 9. 18 replacement of dead end 19 when conductor down to earth as in item no ( 8 ) and ( 9 ) . 20 when conductor required down to earth and restringing including replacement of damaged disc / polymer string and jointing of new conductor pieces as required including jumper providing new jumper. 21 attending breakdown of earthwire / opgw / tightening of loose earthwire / opgw up to 01 km. 22 tightening / fixing of missing / displaced vibration damper / arcing horn....

Telecommunications Consultants India Limited - Uttar Pradesh

30730954 design, engineering, manufacturing, testing, supply, stringing, installation, testing and commissioning etc. of opgw long with hardwares and accessories, termination at both end substations, including replacement of existing earthwire....

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

30668581 supply of hardware fitting for transmission line under etsd iii, chunar at 220 kv substation sahupuri supply of hardware fitting for transmission line under etsd iii, chunar at 220 kv substation sahupuri. supply of compression type single tension fitting will all accessories suitable for acsr panther conductor according iso and duly tested. supply of compression type double tension fitting will all accessories suitable for acsr panther conductor according iso and duly tested. supply of double suspension fitting will all accessories suitable for 132 kv line acsr panther conductor according iso and duly tested. supply of performed armour rod suitable for acsr panther conductor according iso and duly tested. , supply of compression type tension clamp hardware and accessories suitable for gs earthwire 7 / 3.25 mm according iso and duly tested. supply of suspension clamp seated type hardware and accessories suitable for gs earthwire 7 / 3.25 mm according iso and duly tested. supply of mid span joint hardware and accessories suitable for gs earthwire 7 / 3.25 mm according iso and duly tested. supply of vibration damper hardware and accessories suitable for gs earthwire 7 / 3.25 mm according iso and duly tested. supply of copper bond hardware and accessories suitable for gs earthwire 7 / 3.25 mm according iso and duly tested....

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

30668309 providing, fixing and installation of opgw alongwith supply of hardware providing, fixing and installation of opgw alongwith supply of hardware and accessories etc. from tower no. 38 and associated work at 220kv hardoi shahjahanpur line under etd hardoi dismatling of existing earthwirenecessary hardware, re rolling of earthwire on empty drums of opgw of 220kv hardoi shahjahanpur line, & safely transportation of all removed material to upptcl stores etc. 2 installation , laying, testing and commissioning of links etc. of 24 fibre (dwsm) opgw fibre optic cable alongwith all necessary hardware sets excluding joint box. 3 splicing and installation of joint box (24 fibre) 4 installation, termination, testing and commissioning of fibre optic approach cable for 24 f opgw alongwith all necessary hardware sets. 5 supply of 24 fibre (dwsm) opgw fibre optic cable 6 supply of installation hardware set for 24 fibre (dwsm)opgw fibre optic cable including tension assembly, suspension assembly, vibration damper, reinforcing rods, earthing clamps, down lead clamps etc but excluding joint box. one set contains all installation hardware as may be required for installation of 1 km of opgw. 7 supply of joint box (24 fibre) 8 supply of fibre optic approach cable for 24 f opgw 9 supply of installation hardware set ties/clips/cleats, conduits, ducts, trays, supports, fittings, accessories etc for 24 fibre (dwsm, g652 d) fibre optic approach cable . one set contains all installation hardware as may be required for installation of 1 km of fibre optic approach cable. ...

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

30616174 for the supply of opgw for lilo of 132 kv pratap vihar dph line andwork of dismantling of earthwire & installation of opgw along with hardware and accessories etcin live line condition for lilo of 132 kv pratap vihar dph line at 132 kv bsr ii s / s under etd ii ghaziabad...

Telecommunications Consultants India Limited - Uttar Pradesh

30613914 design, engineering, manufacturing, testing, supply, stringing, installation, testing and commissioning etc. of opgw longwith hardwares and accessories, termination at both end substations, including replacement of existing earthwire....

Department Of Culture - Uttar Pradesh

30609661 bids are invited for surface dressing of road with painting surface dressing of road with painting between using 2.25 kg. of bitumen per sqmt. with 1.65 cum of stone chipping 13.2 mm nominal ure / 100 sqmt of road surface including corolidation ( although this job the fore will be given to civil contractor required tank and pump house as per direction of fire department. , 150 mm supplying installation testing & commissioning of butterfly value pn 16 slim seal standard lever operated type as per design standard 15:1395 or 15:5155 with required flanges, nut, bolts etc complete in all respects make; kartar , 100 mm supplying installation testing & commissioning of butterfly value pn 16 slim seal standard lever operated type as per design standard 15:1395 or 15:5155 with required flanges, nut, bolts etc complete in all respects make; kartar , 80 mm butterfly supplying installation testing & commissioning of butterfly value pn 16 slim seal standard lever operated type as per design standard 15:1395 or 15:5155 with required flanges, nut, bolts etc complete in all respects make; kartar , 80 mm supplying installation testing & commissioning of dual plate non return value of following sizes pn 10 as per design standard 15:5312 or 05:1868 with companion fanges, nut, bolts etc complete in all respect make kartar , 100 mm dual plate supplying installation testing & commissioning of dual plate non return value of following sizes pn 10 as per design standard 15:5312 or 05:1868 with companion fanges, nut, bolts etc complete in all respect make kartar , 150 mm dual plate supplying installation testing & commissioning of dual plate non return value of following sizes pn 10 as per design standard 15:5312 or 05:1868 with companion fanges, nut, bolts etc complete in all respect make kartar , manual swing type supplying installation testing & commissioning of manual swing type fire hose reel 15:444 complete with heavy dutyreel 19mm dia 30mtr. long. 2 ply polyster yarn brained rubber braided pressure host. red colored, 55 jet nozzle. 25mm isolating value and all other necessary foxing accessories complete in all respect make neware / m tech new tech , 25 mm air release valve supplying installation testing & commissioningof 25mm air release value gunmental having rubber ball and with 25 mm bsp threadedmale inlet including necessary accessories and connections complete in all respect. , 25 mm ball valve supplying installation testing & commissioning of 25mm ball value pn 1 gunmental as per beating 15 778 including necessary accessories and connections make; zoloto sant , weather proof standard fire house providing / fixing of weather proof standard fire hose cabinet ( 900 mm x 600 mm x 450 mm ) outdoor type made of note les thad 16 / 18 swgms sheet having glassed hinged door ( 5 mm thick glass ) including necessary locking arrangement with handle for housing frydrant valve, two nas, 15 meter long fire hose pipes, branch pipe as required as per drawings including brackets for mounting necessary, painting ( one coat primer and two coat of fire red color ) . the cabined shall be mounted on sell standing mounting type painted ms angle iron frame as required the words fire hose to be painted on the box. , providing / fising of fire hose cabinet box made providing / fising of fire hose cabinet box made out of 18 gauge m5 sheet including two coats of past office red paint over one cost of primer with 4 mm, thick glass door in front painted fire in red luminous paint. the use of the box should be 750 mm x 600 mm x 250 mm sue capable of accommodating a pair of hose with coupling and notable. the bes should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complety. , supply fixing of fire hose, rrl hose jacketed supply fixing of fire hose, rrl hose jacketed with circular waven synthetic fibre confirming to is:636.88 63 mm x15 mtr. long with ss heavy duty, 63 mm paik of male and female instantaneous coupling having 15:903 mark and duly 5.5. wire wounded make, make; newage / m tech, new tech. , supplying fixing of s.s. branch pipe, supplying fixing of s.s. branch pipe, short type with 63 mm male instantaneous intel, male threaded outlet, fitted with 15mm bore nozzle having 15:503 mark make neware / m tech new tech. , main pump , capcity : 1620 imp, head : 70m, hp : 60 supplying installation testing & commissioning of centrifugal horizonal pumping set with bronze impeller with cl body and connected by a flexible ton joy coupling with coupling guard to a totally enclosed with coupling guard to a totally enclosed fan cooler tefc sq. cage induction motore mounted on a common strucural base plate complete as per specification including 1:2:4 pcc foundation motor to be suitable for 415 volts 3 phase 50 cycles ac supply ( 15:325 ) make; kirloskar , fire jocky pump, capacity : 180 imp, head : 88 m, hp 15 supplying installation testing & commissioning of centrifugal horizonal pumping set with bronze impeller with cl body and connected by a flexible ton joy coupling with coupling guard to a totally enclosed with coupling guard to a totally enclosed fan cooler tefc sq. cage induction motore mounted on a common strucural base plate complete as per specification including 1:2:4 pcc foundation motor to be suitable for 415 volts 3 phase 50 cycles ac supply ( 15:325 ) make; kirloskar , bhp, pump capacity : 1620 imp at 70 m head supplying installation testing & commissioning of centrifugal horizonal pumping set with c body and bronze impeller connected by means of a flexible loe joy coupling with coupling guards to a diesel engine monted on a common structural base plate with electric panel better ( including one spare battery ) , automatic starting arrangements, exhaust pipe to discharge outside the building with muffler, 200 liters capacity day oil tank mounted on suitable structural supports complete in all respects as per specifications ready for use including 1:2:4 pcc foundation make kirloskar. , supplying installation testing & commissioning supplying installation testing & commissioning of pressure guage ranging from 0 to 14 kg. per sq.cm. 15 marked from approved manufactures complete in all respect make: h guru , for way supplying fixing of cast iron body 63mm dia male instantneous intel coupling with housing cabinet ( 500x400x400 for 2 wayand 600x400 for 4 way ) cap and chain for fire brigadecorrection with fire fighting pipe or underground water tank completing the work in all respect as per the directions of the engineer in charge. , draw out connection supplying fixing of cast iron body 63mm dia male instantneous intel coupling with housing cabinet ( 500x400x400 for 2 wayand 600x400 for 4 way ) cap and chain for fire brigadecorrection with fire fighting pipe or underground water tank completing the work in all respect as per the directions of the engineer in charge. , automatic control panel supplying installation testing & commissioning of automatic control panel ( s ) for above fire pumps complete with following accessories and details. all the componentsshall housed in a common cubical made of 16 swg ms sheet with required stiffeners. the panel shall be powder coated of approved color both inside & outside. the panel shall have bottom cable entry provision and panel shall be mounted on pedestal of 300 mm height; 32atpn isolator 1 set dol starter, with over load relay, single phase preventer and indicating lamps with on / off push button auto manual selector switch 1 no. also panel shall have no / nc contacts for extending the status ( annunciation of fire pumps to the fire alarm panel ) , 4 core x 10 sq.mm al cable supplying and laying of insulated pvc sheathed steel aromed, copper aluminum conductor, 1100v grade powder cable. the cable shall be laid in tray / in trenches / on wall / floor etc. as required ( approx quantities only ) , 2 core x 2.5 sq.mm cu cable supplying and laying of insulated pvc sheathed steel aromed, copper aluminum conductor, 1100v grade powder cable. the cable shall be laid in tray / in trenches / on wall / floor etc. as required ( approx quantities only ) , 3.5 core x 35 sq.mm al cable supplying and laying of insulated pvc sheathed steel aromed, copper aluminum conductor, 1100v grade powder cable. the cable shall be laid in tray / in trenches / on wall / floor etc. as required ( approx quantities only ) , 3.5 core x 70 sq.mm al cable supplying and laying of insulated pvc sheathed steel aromed, copper aluminum conductor, 1100v grade powder cable. the cable shall be laid in tray / in trenches / on wall / floor etc. as required ( approx quantities only ) , supplying and laying of perforated gi sheet cable supplying and laying of perforated gi sheet cable tray with necessary angle iron suspension supports, anchor fasterners etc. complete maximum height of suspension shall not exceed 500 mm size of the tray is 40 mm x 100 mm x 40 mm and 2 mm thick complete in all respect. ( if required as per site conditions ) , supplying and fixing of gi earth stripes, 25 mm x 3mm supplying and fixing of gi earth stripes, 25 mm x 3mm shall be run of floor / ceiling / walls from the equipment to the nearest earth point. with necessary accessories as required such as clamp, screws etc. complete in all respect ( earth pit shall be executed by other agencies. ) , earthing with gi plate 600 mm x 6 mm x 3 mm thick earthing with gi plate 600 mm x 6 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement & watering pipe etc. ( withcharcoal or coke and salt ) complete as required. , self glow exit signage for stairs and exits size 100x300 supplying and fixing of self glow exit signage for stairs and exits size 100x300 , fire man axe fire man axe , co2type extinguisher 4.5 kg co2type extinguisher 4.5 kg , abc type extinguisher 4 kg abc type extinguisher 4 kg , pressure switch pressure switch , 150 mm dia pipe conforming to is 1239 ( part 1 ) for pipes up to 150 mm dia and is:3589 1991 for pipes above 150 mm including cutting, threading, welding, clamping fitting with elbow, socket nipple, clamping with ms angle iron supports and fasteners etc. also painting with red oxide and po red enamel paint complete in all respects. make: jindal , 100 mm dia pipe conforming to is 1239 ( part 1 ) for pipes up to 150 mm dia and is:3589 1991 for pipes above 150 mm including cutting, threading, welding, clamping fitting with elbow, socket nipple, clamping with ms angle iron supports and fasteners etc. also painting with red oxide and po red enamel paint complete in all respects. make: jindal , 80 mm dia pipe conforming to is 1239 ( part 1 ) for pipes up to 150 mm dia and is:3589 1991 for pipes above 150 mm including cutting, threading, welding, clamping fitting with elbow, socket nipple, clamping with ms angle iron supports and fasteners etc. also painting with red oxide and po red enamel paint complete in all respects. make: jindal , 25 mm dia pipe conforming to is 1239 ( part 1 ) for pipes up to 150 mm dia and is:3589 1991 for pipes above 150 mm including cutting, threading, welding, clamping fitting with elbow, socket nipple, clamping with ms angle iron supports and fasteners etc. also painting with red oxide and po red enamel paint complete in all respects. make: jindal , tank & pump house required tank & pump house as per direction of fire department. tank capacity 50 & pump house size 3.3 m x 5 m x 3.0m height ( as / detail ) , single way tanding valve 63 mm dia gun providing & fixing of single way tanding valve 63 mm dia gun metal instantaneous with female coupling with chain etc. complete make; newage / m tech new tech. , rapping coting for under ground pipe rapping coting for under ground pipe , light with 1.0 sq mm fr pvc wiring points for light with 1.0 sq mm fr pvcinsulated multistrand single core copper condutor cable in heavy guage rigid steel conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complte with 14 swg copper earth contunity wire, piano type switch & ceiling rose / angle / batten holder on 3mm thick phenolic paminated backalite sheet etc. complete in all respects. as directed including matching colour wash. same as item no. 138 ( b ) but in pvc conduit with 1.5 sqmm frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside. , for two way light as in item no. 139 ( b ) but in pvc conductor with 1.5 sq.mm frlsh pvcinsulated multistrand copper conductor cable as earth wire drawn inside the conduit make anchor / hevels. , fan and light duty exhaust fan same as item no. 140 ( b ) but in pvc conduit with 1.5 sqmm fr pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduit. , wiring points for plug with 1.5 sqmm. fr wiring points for plug with 1.5 sqmm. fr pvc insulated multistrand single core copper condutor cable in heavy guage rigid pvc conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 14 swg copper earth contunity wire, piano type switch & socket sheet etc. complete in all respects. as directed including matching colour wash. , supply and fixing of power plug with 15a / 250 volt supply and fixing of power plug with 15a / 250 volt flush type switch and 5 pin 15a / 250volt flush type universal socket in suitable m.s. box of 175mmx100mmx50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. , main and submains suply and wiring of submain with two number 4 sq.mm frlsh pvcinsulated 1100 v grade multistrand single core copper conductor cable in 20mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith reinforcement before continuity wire including matching colour wash etc. complete in all respect. as in item no. 221 ( b ) but in 20mm dia heavy duty ( 2 mm thick ) pvc conduit with one no. 2.5 sq.mm. frlsh pvc insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. , supply and fixing and concealing of 20mm dia. 2mm thick pvc supply and fixing and concealing of 20mm dia. 2mm thick pvc conduit pipe with isi mark embossed and with pvc accessories confirming to is no. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and t&p etc required for proper completion of the work as per directions and to the satisfaction of engineer in charge. , supply and fixing and concealing of 25mm dia. 2mm thick pvc supply and fixing and concealing of 25mm dia. 2mm thick pvc conduit pipe with isi mark embossed and with pvc accessories confirming to is no. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and t&p etc required for proper completion of the work as per directions and to the satisfaction of engineer in charge. , 600x480x200 mm construction of recess of 600mmx480mm x200mm size of main boards, distribution boards of all sizes including cutting of brick work, providing intel of suitable size and thickness, plastering etc. with supply of all materials labour t&p required for proper completion of work. , 600x480x200 mm enamil supply and fixing of factory fabricated m.s. box in existing sunk of size 600mm x 480mm x 200 mm deep with godrej type almirah, cover with handle etc. fabricated from 18 swg ( 1.25mm ) m.s. sheet duly painted with red oxide primer followed by two coats of synthetic enamel paint complete with necessary conduit entry and d.p. / t.p.n.; fixing arrangements and provision for compartment for loose wires openable housing on the top and hold fast etc. including supply of all material, labour, t&p etc. required for proper completion of the work , 4 ways s & f surface / flush mounting 4ways tpn distribution board without additional door without mcb complete in all respect, as directed at site by engineer in charge. , s&f of 6amp to 32 amp. spmcb ( 10 ka ) curve s&f of 6amp to 32 amp. spmcb ( 10 ka ) curve , s&f of 63 amp. 4 pole mcb ( 10ka ) c curve s&f of 63 amp. 4 pole mcb ( 10ka ) c curve , s&f and making connection of 40a 2 pole s&f and making connection of 40a 2 pole 30ma elcb / rccb of din rail mounting complete in all respect asper direction and satisfaction to the engineer in charge. , earthing supply and burying of 600mm x 600mm x 6mm g.i. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia g.i. pipe and funnel for watering and one earthing lead of two no. 8 to 10 swg gi wire in 15mm dia g.i. pipe up to switch board ( from appron to switch board the cost of g.i. pipe and g.i. wire will be extra ) 30cm square c.i. frame with hinged cover masonry housing alternate layers cf charcoal / coke and salt at least 150mm thick alround etc. as per directions of engineer in charge complete in all respect. , supply and fixing of one number 8 swg g.i. wire in 15mm dia. g.i. pipe for earthing, supply and fixing of one number 8 swg g.i. wire in 15mm dia. g.i. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, t&p other material required for proper completion of the work as directed at site. , 16 sqmm 4 core supply and laying of aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. , 35 sqmm 3.5 core supply and laying of aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. , 16 sqmm 4 core cable lead supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer incharge , 35 sqmm 3.5 supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer incharge , 16 sq.mm. supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer incharge , 35 sqmm 3.5 core supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer incharge , cat. b. cubicle type supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel tpn switch board complete with the following hrc type heavy duty tpn fuse switches with fuses and instrument chamber etc. complete in all respects. the instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. the board shall have suitable capacity electroytic aluminium busbars as per is8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as cmc / dmc support with deteachable side covers and shall be suitable for extension on the sides. the switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. , supply and fixing of single light wall bracket supply and fixing of single light wall bracket on matching m.d.f.e.g. board base etc. complete in all respect. , supply and fixing of factory wired, hpf box supply and fixing of factory wired, hpf box type, fluorescent tube light fitting suitable for 1x40 watt fluorescent tube complete including tube etc. on surface complete in all respect. , supply and fixing of factory wired, hpf supply and fixing of factory wired, hpf box type, fluorescent tube light fitting suitable for 2x40 watt fluorescent tube complete including tube etc. on surface complete in all respect. , supply and fixing of half oval glass shade, supply and fixing of half oval glass shade, ceiling fitting with holder cfl 11 watt complete in all respect. , miscellaneous supply and fixing hexagonal / round g.p. fan box of approved make made up of 1.0 mm thick isi marked g.p. sheet spot welded four to eight holes of 25.4mm for pipe entry of the box. holes should be semi shuttered type with 0.5 mm g.p. sheet made upper & lower cover duly screwed fitted with 300mm round zink coted m.s. bar x 12mm & brand name should be embossed. fixing with wiring conduit laid in the r.c.c. roof before concreting alongwith supply of all material, labour, t&p etc. required for proper completion of the work. , supply and fixing danger board supply and fixing danger board fabricated from 10 gauge m.s. sheet as per i.e. rules. , supply and fixing of 16 gauge supply and fixing of 16 gauge m.s. drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. , supply and laying of 1800mmx900mm x 12mm supply and laying of 1800mmx900mm x 12mm thick chequered rubber matting of testing quality , ( make : bajaj / crompton greavs ) supply of ac 230 / 250volt, 50hzceiling fan with srandard down rod, blades, 2 nos. caps etc. complete. , ( make : bajaj / crompton greavs ) 300mm sweep 1400 rpm supply of ac 230 / 250 volt, 50hz exhaust fan including providing nuts, bolts, mounting frame and other accessories, complete total quantity : 1...

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

30384085 tender for annual maintenance work of various 132 kv lines under etsd i under etd, bulandshahr 1 regular tower to tower ground patrolling & tower tip patrolling whenever / wherever required for approximate 88.35 km. following mentioned 132 kv lines. patrolling work consist of detection of the defects like missing / theft to tower parts / members, hot point, punctured / flashed over disc insulators, dislocation of vibration dampers / damaged conductor / earth wire, checking of foundation & position of trees in the corridor of 27 meter of the lines, removing of nests from the tower, patrolling shall be done regularly on quarterly basis ( total four times in a year ) ( a ) 132 kv bhoor jahangirabad line 27.18 km. ( b ) 132 kv bhoor khurja line 17.95 km. ( c ) 132 kv bhoor gulaothi line 19.88 km. ( d ) 132 kv bhoor ii lilo line 7.80 km. ( e ) 132 kv dasna ( 400kv ) gulaothi line 15.54 km.total 88.35 km. 2 opening / cutting of nut & bolts of remaining cut pieces of tower members stolen by miscreants to be opened safely / cut safely with the help of gas cuter / hacksaw blade. fabrication & fixing of tower members including cartage of steel angles from sub station store punching holes for proper placement tightening of nuts & bolts punching & chambering at different tower location of above transmission line and associated work to complete the job satisfactorily as per technical specification. 3 repairing of damaged jumpers with help of pg clamp at tension tower. 4 replacement of damaged / puncture / polymer / insulator string at different tower locations including cartage of material from store to work site of the above line. ( a ) for suspension string. 5 ( b ) for tension string. 6 looping, chopping and cutting of tress branches in the 27 meters corridor of above line and stacking of above cutting at proper place far from the line. 7 removal of birds nest from different tower in respect of above line. 8 tightening / fixing of missing / displaced vibration dampers / arcing horn. 9 tightening of jumpers at tension tower on both side and replacing nut bolt. 10 attending breakdown of broken / repair of panther conductor by providing repair sleeve / mid span compression joints including lowering down of conductor and re hoisting restringing tensioning etc. of the same up to 1 km. along with associated works to complete the job. 11 strengthening of earth wire by fixing of 1500 mm. long pieces of 7 / 10 swg earth wire on suspension tower with help of 04 nos. bull dog clamp duly fixed at both ends. 12 emergency patrolling for attending breakdown of above 132 kv noted lines. 13 attending breakdown of broken earthwire / tightening of loose earth wire per span along with associated work to complete the job satisfactorily. 14 repairing of conductor by providing repairing sleeve when conductor down to earth during attending breakdown of conductor as mention in item no.09 15 manually checking of polymer / disc insulator string from cross arm to tower top of all tower locations, checking of its healthiness....

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

29921519 work of peyjal schemes, government institutes on time to time, the task of issuing the applied combinations on jhatpat and nivesh mitra portal to be completed immediately in full deposite scheme under edsd i under the jurisdiction of electricity distribution division, tundla 1 cartage of the following material fromstore centre, asfabad, firozabad to dump site of work including loading and unloading at the respective ends and also including the work of dragging etc. [ distance 00.00 km to 30.00 km ] 2 8.5 / 9 meter long pcc pole 3 11 / 13 meter long st pole 4 conductor, gi earthwire, cross arm, angle, channel, insulator other line material. 5 11 kv cubical box 15 / 5 amp. 6 16 kva transformer 7 25 kva transformer 8 63 kva transformer 9 100 kva transformer 10 11 kv xlpe cable 3x70 mm / 3 x 120 mm / 3x185 / 3x300 mm 11 drilling of hole in channel, angle. 12 painting of dropper channel, top channel, t channel and guarding angle with 2 quote of red oxide including the cost of paint. 13 safe placement of 8.5 / 9 meter long pcc pole / 11 / 13 meter long st pole from dump site to the pit site of work including the work of dragging of the same through kachha pakka road. 14 erection and grouting of double pole structure of 8.5 / 9 meter long pcc pole including fixing of ht fittings as per respo norms. the support shall be grouted in cement, sand, and brick ballast in ratio 1:2:4. 15 erection of single support of 8.5 / 9 meter long pcc pole including fixing of ht / lt fittings as per respo norms. the support shall be grouted in cement, sand, and brick ballast. 16 erection of single support of 8.5 / 9 meter long pcc pole including fixing of ht / lt fittings as per respo norms. the support shall not be grouted in cement, sand, and brick ballast. 17 erection of single support of 11 / 13 meter long st pole duly grouted in cement, sand and brick ballast in ratio 1:4:8 including fixing of all ht fittings 18 erection of double pole structure of 11 / 13 meter long st pole duly grouted in cement, sand and brick ballast in ratio 1:4:8 including fixing of all ht fittings. 19 construction of plinth of aforesaid newly erected 11 / 13 meter long st pole as per respo norms in cc 1:2:4 ratio in cement, sand and stone grit duly 12 mm thick plaster in 1:4 ratio of cement and sand to give strengthening. 20 grouting, fixing and nozzling of stay rod, andgrouting of stay rod shall be in ratio 1:4:8 [ cement, sand and brick ballast ] , as per respo norm, 21 earthing of ht support through earthing rod & and connecting it properly as per respo norms. 22 chopping of tree branches for clearance of line 23 installation of extra “t” as per respo manual 24 installation of following capacity transformer in proper alignment and direction as per respo manual including the cost of arrangement of labourer, t&p etc required for proper completion of work. 25 16 kva transformer 26 25 kva transformer 27 63 kva transformer 28 100 kva transformer 29 digging, laying and back filling 3x70 / 3x120 / 3x185 / 3x300 mm xlpe cable trench as per respo manual and as per direction of supervising engineer, including the cost of arrangement ofbricks, sand, labourer, t&p etc. required for proper completion of work. 30 installation material contractor arrangeby own his coast installation of following line material in proper alignment and direction as per respo manual, including the cost fo arrangement of labourer, t&p etc. required for proper completion of work for the supervising engineer. 31 11 kv cross arm holding clamp with nut & bolt 32 11 kv u clamp with nut & bolt 33 11 kv f clamp with nut & bolt 34 laying of 3x70 / 3x120 / 3x185 / 3x300 sqmm. xlpe cable in open and its making connection with transformer and 11 kv feeder also as per direction of supervising engineer. 35 laying, stringing, sagging, binding and jumpering etc of weasel conductor as per respo norms. 36 laying of ariel bunch conductor cable of size 3x50 sqr. mm / 3x95sqr mm 37 laying, stringing, sagging, binding and jumpering etc of dog conductor as per respo norms. 38 guarding of 11 kv line. 39 installation of distribution box as per respo manual and as per direction of supervising engineer. 40 fixing of tpmo fuse set on newly erected transformers. 41 installation of 11 kv cubical box 15 / 5 amp. 42 filling and fixing of cable box suitable for xlpe cable, including the cost of arrangement of labourer, t&p etc. required for proper completion of work, but the box shall be provided by the corporation free of cost, as per actual sit requirement....

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

29921102 work of annual maintenance of various 132kv transmission lines under etd i ghaziabad 1 regular tower to tower patrolling wherever required of following 132kv transmission line , detection of the defects like missing / theft tower members , puncture insulator disc, dislocation of vibration damper / damaged conductor / earth wire, checking of foundation & position of tree in the corridor of 35mtr of the line and removing of bird nest from towers patrolling shall be done 01 time in 03 months i.e. 04 times in a year and some part of line passes through critical areas ( approx.20km ) which require additional patrolling @ monthly wise. 2 132kv loni kanha upwan line 29 km 3 132kv sahibabad mohannagar line 9km 4 132kv morti khanaupvan line 0.70km 5 132 kv morti mohan nagar line 1.3 km 6 132kv loni teelamod line 8.5km 7 132kv sahibabad vaishali line 2.5km 8 fabrication & fixing of tower parts / members from scrap gi angles includinf cartage of steel angles from the substation store, punching holes proper placement tightning of nuts & bolts, punching & champfering of bolts at different location of above transmission line. 9 tack welding of nut bolts 10 replacement of damaged jumpers at tension towers 11 tightning of jumpers at tension tower 12 looping, chooping and cutting of trees branches in the 35mts corridor of 132kv lines , stacking of above cutting at proper place far from the line 13 tighting / fixing of missing / displaced vibration dampers / arcing horns. 14 emergency patrolling of 132kv lines during tripping to detect the exact fault location and type of fault 15 reparing of damaged acsr panther conductor by jointing with one number repair sleeve including lowering down of conductor and restringing of the same with all other associated work to complete the job satisfactorly. 16 reparing of damaged acsr panther conductor by tension fitting as per requirement of site including lowering down of conductor and restringing of the same for completion of the work satisfactory. 17 attending breakdown of broken acsr panther / htls conductor by winding and fixing required mid span compressing joint including lowering down the conductor and restringing the same ( upto 01km ) 18 replacemnt of damaged / punctured suspension polymers stringhs as per site requirement, including carriage of matetial from store to work site. 19 removal of foreign material from the conductor / earthwire of the above lines like kites, wire etc....

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

29919213 work of peyjal schemes, government institutes on time to time, the task of issuing the applied combinations on jhatpat and nivesh mitra portal to be completed immediately in full deposite scheme under edsd ii under the jurisdiction of electricity distribution division, tundla 1 cartage of the following material fromstore centre, asfabad, firozabad to dump site of work including loading and unloading at the respective ends and also including the work of dragging etc. [ distance 00.00 km to 30.00 km ] 2 8.5 / 9 meter long pcc pole 3 11 / 13 meter long st pole 4 conductor, gi earthwire, cross arm, angle, channel, insulator other line material. 5 11 kv cubical box 15 / 5 amp. 6 16 kva transformer 7 25 kva transformer 8 63 kva transformer 9 100 kva transformer 10 11 kv xlpe cable 3x70 mm / 3 x 120 mm / 3x185 / 3x300 mm 11 drilling of hole in channel, angle. 12 painting of dropper channel, top channel, t channel and guarding angle with 2 quote of red oxide including the cost of paint. 13 safe placement of 8.5 / 9 meter long pcc pole / 11 / 13 meter long st pole from dump site to the pit site of work including the work of dragging of the same through kachha pakka road. 14 erection and grouting of double pole structure of 8.5 / 9 meter long pcc pole including fixing of ht fittings as per respo norms. the support shall be grouted in cement, sand, and brick ballast in ratio 1:2:4. 15 erection of single support of 8.5 / 9 meter long pcc pole including fixing of ht / lt fittings as per respo norms. the support shall be grouted in cement, sand, and brick ballast. 16 erection of single support of 8.5 / 9 meter long pcc pole including fixing of ht / lt fittings as per respo norms. the support shall not be grouted in cement, sand, and brick ballast. 17 erection of single support of 11 / 13 meter long st pole duly grouted in cement, sand and brick ballast in ratio 1:4:8 including fixing of all ht fittings 18 erection of double pole structure of 11 / 13 meter long st pole duly grouted in cement, sand and brick ballast in ratio 1:4:8 including fixing of all ht fittings. 19 construction of plinth of aforesaid newly erected 11 / 13 meter long st pole as per respo norms in cc 1:2:4 ratio in cement, sand and stone grit duly 12 mm thick plaster in 1:4 ratio of cement and sand to give strengthening. 20 grouting, fixing and nozzling of stay rod, andgrouting of stay rod shall be in ratio 1:4:8 [ cement, sand and brick ballast ] , as per respo norm, 21 earthing of ht support through earthing rod & and connecting it properly as per respo norms. 22 chopping of tree branches for clearance of line 23 installation of extra “t” as per respo manual 24 installation of following capacity transformer in proper alignment and direction as per respo manual including the cost of arrangement of labourer, t&p etc required for proper completion of work. 25 16 kva transformer 26 25 kva transformer 27 63 kva transformer 28 100 kva transformer 29 digging, laying and back filling 3x70 / 3x120 / 3x185 / 3x300 mm xlpe cable trench as per respo manual and as per direction of supervising engineer, including the cost of arrangement ofbricks, sand, labourer, t&p etc. required for proper completion of work. 30 installation material contractor arrangeby own his coast installation of following line material in proper alignment and direction as per respo manual, including the cost fo arrangement of labourer, t&p etc. required for proper completion of work for the supervising engineer. 31 11 kv cross arm holding clamp with nut & bolt 32 11 kv u clamp with nut & bolt 33 11 kv f clamp with nut & bolt 34 laying of 3x70 / 3x120 / 3x185 / 3x300 sqmm. xlpe cable in open and its making connection with transformer and 11 kv feeder also as per direction of supervising engineer. 35 laying, stringing, sagging, binding and jumpering etc of weasel conductor as per respo norms. 36 laying of ariel bunch conductor cable of size 3x50 sqr. mm / 3x95sqr mm 37 laying, stringing, sagging, binding and jumpering etc of dog conductor as per respo norms. 38 guarding of 11 kv line. 39 installation of distribution box as per respo manual and as per direction of supervising engineer. 40 fixing of tpmo fuse set on newly erected transformers. 41 installation of 11 kv cubical box 15 / 5 amp. 42 filling and fixing of cable box suitable for xlpe cable, including the cost of arrangement of labourer, t&p etc. required for proper completion of work, but the box shall be provided by the corporation free of cost, as per actual sit requirement....