Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

34049261 testing and commissioning of various 33 kv triple feeder numerical control and relay panel under etd badaun 1 testing and commissioning of erl make 33 kv triple feeder numerical control & relay panel including conformation of 03 nos. numerical relays ( model no. erl fpro ) at 132 kv substation aonla . 2 testing and commissioning of abb make 33 kv triple feeder numerical control & relay panel including conformation of 03 nos. numerical relays ( model no. ref 620 ) at 132 kv s.a.s substation ujhani . 3 testing and commissioning of abb make 33 kv triple feeder numerical control & relay panel including conformation of 03 nos. numerical relays ( model no. ref 615 ) at 132 kv s.a.s substation bilsi ....

Nagar Panchayat - Uttar Pradesh

33874410 supply of automated control panel upto 25 hp , starter panel with rtu controller for one over head tank with 2 nos.tw rtu controller & starter panel along with relevant switchgear mounted on base plate with one year warrany as mention below: mccb ( 63 amp ) gsm / gprs 4g modem with antenna soft starter with delta connectionpower monitor with suitable size current transformer power supply ( smps ) control relay control relay push button for start stop operation selector switch for local / remote operation 230vac led with wiring & accessories mcb, 6a dp on / off / trip indication lamp sitc of water level sensor for the monitoring water level in overhead tank ( 1 nos ) sitc of cloud based software for monitoring of overhead tanks and tube wells. ( 1 nos ) with all taxes...

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

33755172 maintenance of 220kv, 132kv and 33kv equipments for three month at 220kv substation naubasta kanpur under etd ii kanpur 2 220kv control & relay panel ( 10nos. ) 3 132kv control & relay panel ( 20nos. ) 4 33kv control & relay panel ( 10nos. ) 5 dismantling of following rating old & damaged jumpers and fixing of new jumpers by acsrpanther / zebra conductor from bus bar to equipment and equipment to equipment. 6 220kv jumper 7 132kv jumper 8 33kv jumper 9 replacement and repairing of damaged / burnt terminal connector of following rating equipments by new terminal connector. 10 220kv terminal connector 11 132kv terminal connector 12 33kv terminal connector 13 replacement and repairing of damaged / burnt jaw / blade assembly of the following rating isolator and replacement by new one. 14 220kvisolator 15 132kv isolator 16 33kv isolator 17 adjustment of mechanism, overhauling and greasing of following rating isolators including petty repair of any. 18 220kvisolator 19 132kv isolator 20 33kv isolator 21 replacement / reacharging of silica jel granules offollowing rating of the transformers including dismantling of silica jel breather and cleaning of the breather pots & its refiting 22 220 / 132kv, 160mva t / fs 23 132 / 33kv, 63 / 40mva t / fs 24 33 / 0.4kv, 250kva t / fs...

Kanpur Electricity Supply Co Limited - Uttar Pradesh

32930485 supply of 33 / 11kv 10 mva schneider make power transformer and 11 kv and 33 kv schneider make switchgear 33 / 11kv 10 mva schneider make power transformer and 11 kv and 33 kv schneider make switchgear , electrical items : , 33 / 11 kv power t / f 10 mva with off load tap changer ( schneider make ) . , 33 kv vcb with structure 1500 mva 1250amp. with 33 kv control relay pannel for single t / f ( schneider make or equivalent ) . , 11 kv i / c vcb pannel 350 mva, 1250 amp, ct ratio 600 / 300 / 5 amp. with p.t ( schneider make ) . , 11 kv o / d vcb pannel 350 mva, 1250 amp, ct ratio 600 / 300 / 5 amp. ( schneider make ) . , 11 kv bus coupler vcb pannel 1250 amp. ( schneider make ) . , 11 kv adaptor pannel for matching bus bar....

Uttar Pradesh Housing And Development Board - Uttar Pradesh

32651021 electrical / mechanical work in 50 bedded eye hospital at ramai patti tehsil sadar district mirzapur electrical / mechanical work in 50 bedded eye hospital at ramai patti tehsil sadar district mirzapur 1 wiring point for light with 1.5 sq. mm.frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sqmm frlsh pvc insulated multistrand copper conductor cable as earth wire drawn inside the conduit with gp box, modular type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. pwd sor 2018 si no 138(c)+187(a) 2 wiring point for two way light with 1.5 sq. mm. frls pvc insulated multistrand single core copper conductor cable in heavy guage pvc conduit. pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 1.5 sq. mm. frlsh pvc insulated multistrand copperconductor cable as earthwire drawn inside the conduit, gp box and 2no. two way modular type switches and ceiling rose /angle /batten holder on 3 mm. thick phenolic laminated backlite sheet etc. complete in all respects, as directed including matching colour wash.pwd sor 2018 si no 139(c) + 187(b) 3 wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm.frlsh pvc insulated multistrand copper conductor cable as earth wiredrawn inside the conduit withmodular type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. pwd sor 2018 sl no 140(c )+ 187(a) 4 wiring point for call bell with 1.5 sq. mm. frls pvc insulated multistrand single core copper conductor cable in heavy guage pvc conduit. pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 1.5 frlsh pvc insulated multistrand copperconductor cable as earthwire drawn inside the conduit, gp box and modular type bell push or 2 pin shocket etc complete in all respects, as directed including matching colour wash. pwd sor 2018 si no 142(c) + 187(e) 5 wiring point for plug with 1.5 sq. mm.frlsh pvc insulated multistrand copper onductor cable in pvc conduitpartly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm.frlsh pvc insulated multistrand copper conductor cable as earth wiredrawn inside the conduit and modular type switch and socket etc., complete in all respect including matching colour wash.pwd sor 2018 sl no 141(c )+ 187(a) 6 supply and wiring of submain with two number 2.5 sq.mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) pvc conduit partly laid in slab alongwith the reinforcement before concreting and partly concealed in wall with 1 nos. 1.5 sq. mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. including matching colour wash. pwd sor 2018 sl no 1307(c ) 7 supply and wiring of submain with two number 4 sq.mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with one no. 2.5 sq. mm. frlsh pvc insulated multistrand copper conductor cable as earth continuity wire drawn in conduit including matching colour wash etc. complete in all respect. pwd sor 2018 sl no 221(c ) 8 supply and wiring of sub main with two number 6.0 sq.mm frlsh pvc insulated 1100 v grade multstrand single core copper conductor cable in 20 mm dia heavy duty(2mm thick) pvc conduit partly concealed in wall and partly laid in slab along with reinforcement before concretiing with 1 no. 4.0 sq.mm. frlsh pvc insulated multstrand copper conductor cable as earth continuity wire drawn iin conduit including matching colour wash. complete in all respect pwd sor 2018 si no 222(c) 9 supply and wiring of 4 number 6 sq. mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2mm thick) pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with 2 nos 4 sq.mm. frlsh pvc insulated copper conductor cable as earth continuity wire drawn in conduitincluding matching colour wash etc. complete in all respect..pwd sor 2018 sl no 277(c ) 10 supply and wiring of 4 number 10 sq. mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2mm thick) pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with 2 nos 6 sq.mm. frlsh pvc insulated copper conductor cable as earth continuity wire drawn in conduitincluding matching colour wash etc. complete in all respect..pwd sor 2018 sl no 278(c ) 11 supply and wiring of sub main with 4 number 16.0 sq.mm frlshpvc insulated 1100 v grade multstrand single core copper conductor cable in 40mm dia pvc conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting with two number 10 sq.mm. rlsh pvc insulated copper conductor cable as earth continuity wire drawn in conduitincluding matching colour wash etc. complete in all respect. pwd sor 2018 si no 279 (c) 12 supply and fixing hexagonal/round g.p. fan box of approved make made up of 1.0 mm thick isi marked g.p. sheet spot welded four to eight holes of 25.4 mm for pipe entry of the box. holes should be semi shuttered type with 0.5 mm g.p. sheet made upper & lower cover duly screwed fitted with 300 mm round zink coated m.s bar x 12 mm & brand name should be embossed. fixing with wiring conduit laid in the r.c.c. roof before concreting along with supply of all material, labor, t&p etc. required for proper completion of the work .pwd sor 2018 s.i.no. 1149 13 supply and fixing of led tube light with metal heavy duty box type batten light fitting 1 x 22 watt suitable for upto 1x22 watt led polycarbonate tube light complete including tube suitabe for both surface & suspended complete in all respect. 2420 system lumens, 110lm/watt pf>0.95, thd<10% cri>80, sheet thicknes 0.8mm, tube with aluminium heat with 5 year warrantee. pwd sor 2018 sl no 1413 cat aaa 14 supply and fixing of led tube light with metal heavy duty box type batten light fitting 2x 22 watt suitable for upto 2x22 watt led polycarbonate tube light complete including tube suitabe for both surface & suspended complete in all respect. 2420 system lumens, 110lm/watt pf>0.95, thd<10% cri>80, sheet thicknes 0.8mm, tube with aluminium heat with 5 year warrantee. pwd sor 2018 sl no 1414 cat aaa 15 supply and fixing of recess/surface mounting round 24 watt to 32 watt cut out min 150 mm height min 40 mm, led down lighter having powder coated die cast aluminium housing with heat sink diffuser/reflector and driver set suitable for 24 hr continuous operation, compelete in all respect. pwd sor 2640 3520 system lumens, 110lm/watt pf>0.95, thd<10% at full load, cri>80, with 5 year warrantee. si no. 1405 cat aaa 16 supply and fixing of water tight oblong 10 watt led bulkhead luminaire with driver set confirming to ip 65 and above protection . complete in all respect. si no. 1417 cat aaa 17 supply and fixing of 36 watt to 46 watt indoor recess mounting led square fitting for armstrong ceiling having powder coated die cast aluminium housing body with extended heat sink and diffuser of special polycarbonate meterial and driver set complete in all respect.pwd sor 2018 s.i.no. 1406 cat a 18 supply and erection of 300 mm sweep ac 230/250 volts, 50 hz exhast fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required connection etc. complete as required mr 19 supply and erection of 400 mm sweep ac 230/250 volts, 50 hz wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required connection etc. complete as requiredmr 20 supply and fixing of electronic fan regulator (modular) 120 280 v. isi marked, on the existing switch board including making connections, required material, labour t&p etc. for proper completion of work to the satisfaction of engineer in charge of work. pwd sor 2018 s.i.no. 1203 (c ) 21 supply and erection of ceiling fan with motor of ac permanent insulation, capacitor rating conforming bee 5 star rating and is:374/79 and also comply with is: 1709/ 1984 with latest amendment. the rated voltage 220/240 volts, 50hz 1 ph ac the fan assemble should consists of down rod, blades, shackle, canopies etc and with double ball bearing system .pwd sor 2018 si no 1501+ 1115 bee 5 star rated 1200 mm sweep 22 s/f of 3mm thick bakelite sheet cover round/hexagonal type for fan box complete with all material, labour t&p as per direction of e/i. 23 s/f of 3mm thickal. sheet junction box cover complete in all material labour t&p as per direction of e/i. 24 supply and fixing of surface/ flush mounting 8 way tpn distribution board with additional metal door without mcb complete in all respect and directed at site by e/i. pwd sor 2018 si no 1027(a)cat a 25 s&f of 6 amp to 32 amp. spmcb (10 ka) c curve pwd sor 2018 si no 1002 cat a 26 s&f of 63 amp. 4 pole mcb (10 ka) c curve pwd sor 2018 si no 1020 (a) 27 supply and fixing of power plug with 20 amp./250 voltflush type modular switch and 5 pin 20 a/250 volt flush type universal modular socketswitch on concealed m.s boxincluding supply of all material, labour t&p etc. required for proper completion of work. pwd sor 2018 si no 1139(a) 28 s & f sheet steel enclosure surface / flush mounting fitted with 30amp. 2pin and earth metal clad scraping earth plug and socket complete in all respect. as directed at site byengineer in charge.1031 (a) 29 s & f surface/flush mounting 4ways v tpn distribution board with additional metal door without mcb complete in all respect,as directed at site by engineer in charge.pwd sor 2018 si no 1026 (c ) 30 s&f of 80 to 100 amp 4 pole mccb (16 ka) thermal magnetic releasepwd sor 2018 si no 1021 31 supply and burring of safe earthing electrode t 39 zn zinc coated, length 3000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal dia 12mm, coating 80 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square c.i. frame with hinged cover & masonry housing. (from electrode terminal to switch board, cost of 25 x 3 g.i. strip will be extra make: as approved in u.p. p.w.d., & c.p.r.i. certified pwd sor 2018 si no 726 (d) 32 supply and laying of 25 mm x 3 mm g.i srtip form earth electrode directly in the ground as required complete in all respects. pwd sor 2018 si no 716 33 supply and laying of 32 mm x 6 mm g.i. strip from earth electrode directly in the ground as required complete in all respect. pwd sor 2018 si no 717 34 providing, laying and fixing 80 mm dia g.i. pipe (medium class) in ground complete with g.i. fittings including trenching (75 cm deep)and re filling etc as required. dsr 2018 si no 18.12.8 35 supplyandlayingof aluminiumconductorpvcinsulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. pwd sor 2018 si no 501 36 10 sqmm 4 core 37 16 sq mm 4 core 38 70 sq mm 3.5 core 39 95 sq mm 3.5 core 40 240 sq mm 3.5 core 41 supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. the armouring ofthe cable shall be properly connected with the earth as per direction of engineer incharge.pwd sor 2018 si no 503 42 10 sqmm 4 core 43 16 sq mm 4 core 44 70 sq mm 3.5 core 45 95 sq mm 3.5 core 46 240 sq mm 3.5 core 47 supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the engineer incharge.pwd sor 2018 si no 504 48 10 sqmm 49 16 sq mm 50 35 sq mm 51 50 sq mm 52 70 sq mm 53 95 sq mm 54 120 sq mm 55 240 sq mm 56 supply and fixing of call bell of approved make on polished mdfeg / teak ply board including making connections etc. complete in all respect. pwd sor 2018 si no 1101 57 supply of franklin france make advanced piezoelectric exciter device based lighting protection system suitable for protection of building against direct lightning strike complete with ealy streamer emission with piwezoelectric device for corona effect) stainlles steel lighting conductor air terminal with event counter with sensitivity 1 ka to 100 ka for 8.20 micro second impulse for 1 ka control over the release of ions positive or negative without additional power supplies requirement required complianece with ip53 enclosures) 58 saint elmo lightening conductor with discharge counter (sensitivity 1 ka, 8/20 microsecound with ip 53 enclosures) 59 elevation rod : 2m. afc2001 two elevation rods for are required for mounting a one lightening conductor mr 60 installation of franklin france make external lightening protection system. 61 supply and fixing of vertical down conductor of 32mm x 6mm g.i. strip etc. on approved clamps on surface for lightning conductor complete in all respects (for two storeyed buildings).p.w.d.s.o.r. 2018 s.i. no.713( c) 62 supply and fixing of testing joint of g.i. strip 32mm x 6mm and 150mm long with g.i. bolts and nut etc. complete in all respect.p.w.d.s.o.r. 2018 s.i. no.719 63 supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. (i)telephone socket outlet dsr no 1.24.6 64 supply and fixing of g.p. modular switch box for 1 / 2 module of approved make made up of 1.0 mm thick isi marked g.p.sheet including adjestable nakka and holes plugged with pvc nylon caps . two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box. holes should be semi shuttered type and fitted with heavy brass earth piller duly screwed & brand name should be embossed. box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and t&p required for proper completion of work as directed at site by the engineer in charge. p.w.d.s.o.r. 2018 s.i. no.1152(a)(i) 1 or 2 module (75mm x 75 mm) 65 supplying and drawing telephone wire following pair 0.5 sqmm fr pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/pvc conduit as required. dsr no 1.18.22 pair 66 supply and fixing and concealing of 20 mm dia. 2mm thick pvc conduit pipe with isi mark embossed and with pvc accessories confirming to is no. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and t&p etc required for proper completion of the work as per directions and to the satisfaction of engineer in charge. sor 2018 si no. 148(a) 67 supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality sor 2018 si no. 1136 68 fire fighting systemproviding, laying, testing & commissioning of c class heavy duty ms pipe conforming to is 3589/is 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : dsr & aor 2019 si no 7 69 150 mm dia 70 100 mm dia 71 80 mm dia 72 65mm dia 73 32mm dia 74 25 mm dia 75 providing laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required. dsr & aor 2019 76 150 mm dia si no 6.2 77 supplying,fixing, testing and commissioning of manual swing typehose reel is:444 complete with heavy duty reel, 20 mm dia. x 30 mtr long, pvc pressure hose pipe , red coloured, ss jet nozzel, 25mm. isolating valve and all other neccessary fixing accesories complete in all respect. dsr no 17:1 78 supplying and fixing single headed internal hydrant valve with instantaneous gunmetal/stainless steel coupling of 63 mm dia with cast iron wheel isi marked conforming to is 5290 (type a) with blank gunmetal/stainless steel cap and chain as required :as per dsr & aor 2019 s.i. no. 9.1 79 supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to is 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : dsr & aor 2019si no. 18.1 80 supplying and fixing 63 mm dia, 15 m long rrl hose pipe with 63 mm dia male and female couplings duly bound with gi wire, rivets etc. conforming to is 636 (type a) as required : dsr & aor 2019 si.no.16.1 81 providing and fixinghose box (600x300x200)size of suitable size made out of 16/18 swg thick having central opening and 4 mm thick glazed glass double door including necessory rubber beading key pocket, handle locking arrengment painting with polyurethene based red paint etc. the words fire hose to be painted on the dooor as per approved drawing complete in all respect. mr 82 supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia ms pipe connection conforming to is 904 as required : 83 2 way 100 mm dia m.s. pipe si no. 19.1 84 supply, fixing, testing and commissioning of 25mm ball valve complete. mr 85 supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. dsr & aor 2019 si no. 20 86 supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required: (main fire pump)(a) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to is : 1520(b) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase, 50 hz, ac supply with ip55 class of protection for enclosure, horiziontal foot mounted type with class f insulation, conforming to is 325.(c) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) suitable cement concrete foundation duly plastered and with anti vibration pads.supplying and fixing air vessel made of 250 mm dia, 8 mm thick ms sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.1620 lpm at 70 m head dsr & aor2019 si no. 1.8 87 supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump)horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.make : kirloskar/ other standard make.dsr no. 2.81620 lpm at 70 m head 88 supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump) a) horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.b) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class f insulation, conforming to is : 325.c) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads. make kirloskar/other standard make dsr no. 3.2180 lpm at 70 m head 89 supplying, installation, testing and commissioning of electric driven terrace pump suitable forutomatic operation and consisting of following, complete in all respects, as required: (terrace pump)(a) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to is : 1520 b) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase, 50 hz, ac supply with ip55 class of protection for enclosure, horiziontal foot mounted type with class f insulation, conforming to is 325. (c) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m head 90 automatic control panel(s) fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required : incoming 250a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0 500v with selector switchdigital ammeter (0 250 a) with selector swtich & cts etc.outgoing main fire pump : 125 a 50ka tpn mccbjockey pump : 63 a , 50ka tpn mccb, diesel engin control complete in all respect dsr no. 5.1 91 providing & fixing of pressure switch in m.s. pipe line including connection etc. as required. dsr & aor 2019 si no. 22 92 providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required dsr 2018 si no. 16.8 93 sitc of foot valves with strainer at the suction pipe of fire pumps (in case of negative suction only). make kalpana/kartarsir/advance or equivalent 94 150mm dia 95 100mm dia 96 supplying, fixing, testing and commissioning of butterfly valve of pn 1.6 rating with bronze/gunmetal seat duly isi marked complete with nuts, bolts, washers, gaskets conforming to is 13095 of following sizes as required : dsr & aor 2019 si no 11 97 150 mm dia 98 100 mm dia 99 80 mm dia 100 providing, installation, testing and commissioning of non return valve of following sizes confirming to is: 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required : dsr & aor2019 si no. 14 101 150 mm dia 102 100 mm dia 103 supply and fixingof c02 type fire extinguisher 4.5 kg. capacity (isi marked is : 2878 & tac approved) complete with initial charge and wall bracket, along with supply of all materials and labourfor proper completionof work.pwd sor 2018 si no 1132 104 supply and fixingof fire extinguisher,abc type 6.00 kg. capacity(isi marked is : 15683 & tac approved) complete with initial charge and wall bracket, along with supply of all materials and labourfor proper completionof work.pwd sor 2018 si no 1131(a) 105 supply and fixing of self glow type exit sinage. 106 sitc ofsprinkler 68° deg, complete in all respects. (make: omex/ life guard/safex) dsr 2019 si no. 21.1pendent type 107 fire alarm system worksupplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card,minimum 320 character graphics/ lcd display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (eprom), power supply unit (230± 5% v, 50 hz), 48 hrs back up with 24 volt sealed maintenance free batteries with automatic charger. the panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under sh: pa system) and shall be complete with all accessories . the panel shall be compatible for ibms system with open protocol bacnet/ modbus over ip complete as per specifications. dsr 2018 si no 17.2.1.1two loop panel. 108 supplying, installation, testing & commissioning of intelligent analog addressable photo thermal detector complete with mounting base complete as required. dsr 2018 si no 17.2.4 109 supplying, installation, testing & commissioning of response indicator on surface/recessed ms box having two led, metallic cover complete with all connections etc as required.dsr 2018 si no 17.2.5 110 supplying, installation, testing & commissioning of addressable phone control module complete as required. dsr 2018 si no 17.2.11 makeinnel/simplex/tyco 111 supplying, installation, testing & commissioning of addressable manual call point complete as required. dsr 2018 si no 17.2.14 112 supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. dsr 2018 si no 17.2.15 113 supplying, installation, testing & commissioning of addressable fire control module complete as required. dsr 2018 si no 17.2.10 114 supplying, installation, testing & commissioning of faultisolator complete with base as required. dsr 2018 si no 17.2.7 115 supplying, installation, testing & commissioning of repeater panel wih 320 character/ touch screen lcd display with inbuilt reset ackowledge and silence switches complete as required.dsr 2018 si no 17.2.3 116 supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000v rated with annealed copper conductor having xlpe insulation, steel wire armouring & frls outer sheath complete as required.. dsr 2018 si no. 17.5.2 117 supplying, installation, testing & commissioning of 6 zone,voice alarm controller with usb, mp3 player (including 6 zonebutton paging station) with seamless integration facility withmain fire alarm panel for voice evacuation complete asrequired dsr 2018 si.no.17.3.1 118 supplying, installation, testing & commissioning of 1.5/3/6w metal box ceiling/wall speakers complete as required.dsr 2018 si.no.17.3.3 119 supplying, installation, testing & commissioning of digital audio amplifier 50 watt, 25v rms operating at 240 volt ac supply complete as required.dsr 2018 si.no.17.3.6 120 supplying, installation, testing & commissioning of voice command keypad 6 zone, with microphone assembly complete as required.dsr 2018 si.no.17.3.9 121 tubewell workboring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in is: 2800 (part i), including collecting samples from different strata, preparing and submitting strata chart! bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90 metre depth below ground level. dsr 2019 sino. 23.1.1 122 350 mm dia upto 60 msino. 23.1.1.2 123 60 90 msi no. 23.1.1.1 124 90 150 msi no. 23.2.1.1 125 supplying, assembling, lowering and fixing in vertical position in bore well, erw (electric resistance welded) fe 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to is: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of engineer in charge. dsr 2019 si no. 23.10 126 150 mm nominal size dia having minimum wall thickness 5.00 mm si no. 23.10.2 127 200 mm nominal size dia having minimum wall thickness 5.40 mm si no. 23.10.3 128 supplying, assembling, lowering and fixing in vertical position in bore well, erw (electric resistance welded) fe 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type a) of required dia, conforming to is: 8110, of reputed and approved make, having wall thickness not less than 5.40 mru, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fitting & accessories, all complete, for all depths, as per direction of engineer in charge. dsr 2019 si no. 23.11 150 mm nominal size dia si no. 23.11.2 129 providing and fixing bail plug/ bottom plug of required dia to the bottom of pipe assemblv of tube well as oer is:2800 (dart n.dsr 2019 si no. 23.15 150 mm dia si no. 23.15.2 130 providing and fixing m.s. clamp of required dia to the top of casing! housing pipe of tube well as per is: 2800 (part i), including necessary bolts & nuts of required size complete. dsr 2019 si no. 23.14(i) 200 mm clamp si no. 23.14.3 131 supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. dsr 2019 si no. 23.6 132 development of tube well in accordance with is : 2800 (part 1) and is: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by v notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, ilc disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of engineer in charge dsr 2019 si no. 23.12 133 providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing! casing pipe, rmovable as per requirement, all complete for borewell of: dsr 2019 si no. 23.13 200 mm dia si no. 23.13.3 134 500 lpm 52 m head of k s b make submersible pumping plant sitc submersible pump set suitable for clear and cold water with bronze impellers and built in non return valve and suitable to run on 400 volts, 3 phase 50 hz a.c. supply at 2900 rpm (nominal) speed and complete with 3 mts. submersible cable. 135 sitc of sheet steel fabricated cubical type wall mounting type panel with front opening door. the panel will be complete with internal wiring and will have 3 nos. instruments fuses and 3 nos. toggle switches. 136 main piping and valves (01 no ci df reflux valve, 02 no ci df sluice valve, 01 no ci df bend, 01 no enlarger of necessary size, if required, 01 no ci af tee, 01 no ci df pipe 1.0 mt long, 02 nos ms df pipe 1.5 mt long, 30 mts ms column pipe flanged type in lenghts of 3.0 mts each, 02 pairs column pipe clamps) 137 pressure & depth gauge (01 no 100 mm dial size pressure gauge feibiq make, 01 no 100 mm dial size depth gauge feibiq make, 01 no control cock for pressure gauge, 35 mts. steel air line with sockets, 01 sets union joints, schraeder valve, hand air pump and gauge board etc.) 138 lifting tackle indef make spur geared lifting tackle of capacity 02 tonnes tested to 03 tonnes with load and hand chain for 4.5 mts lift. 139 special tools and spanners (01 no wooden tool board with l hooks, 01 no hammer with handle, 01 set de spanners consisting of 06 pcs, 02 nos screwdrivers, 01 no 350 mm size pipe wrench, 01 no combination plier) 140 installation of one complete pump set with switchgear material, main piping and valves and do the power wiring work. 141 commissioning of one pumping plant as and when the department arranges the power connection at the site. 142 painting of the switchgear material and delivery pipes and special inside the pump house with 02 coats of enamel paints. 143 testing of the pump at site and the test will be subject to tolerences as provided in the relevant iss. 144 chlorinatorsupply of aquas make electronic chlorinator of 6lph capacity complete accessories and 100 ltr, pvc solution tank. 145 installation charges (1/2 socket fixed in pipe line to provide by the department, 146 street lightsupply and fixing of 7.0 meter long g.i. octogonal pole top dia 70 mm bottom dia 130 mm andbase plate 12 mm thick having3 mm thickness with single arm braclet (1 meter length ) on rcc foundatoion including the cost of foundation ,foundation bolts, excavation & baack filling and required t&p complete fn all respect pwd sor 2018 s.i. no 641 147 supply and fixing of led street light fitting having dia cast aluminium body and diffuser with driverset suitable for 75 to 90 watt. confirming to ip 65 and above protection complete in all respect. pwd sor 2018s.i.no. 1423 cat aaa 148 providing, laying and fixing following dia g.i. pipe (medium class) in ground complete with g.i. fittings including trenching (75 cm deep)and re filling etc as required80 mm dia sor aligarh 2020 149 supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors , hrc fuses, isolatingswitch metering intrument & instrument box with cts etc. in case of tpn, comp;ete in all respect pwd sor 2018 s.i.no. 807 40 a tpn 150 supply and laying of 25mm x 3mm g.i. strip from earth electrode directly in the ground as required complete in all respect. pwd sor 2018 s.i.no. 716 151 supply and burring of safe earthing electrode t 19 (hot dip galvanized), length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal dia 12 mm, outer gi pipe of 16 swg and inner gi pipe of 12 swg with hot dip galvanization up to 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 g.i . strip will be extra) make: as approved in u.p. p.w.d., & c.p.r.i. certified. pwd sor 2018 s.i.no. 725 (a) 152 solar water heaterspecial system featuresevacuated tube collectorno. pressurized tankgi tank with special passivation coating & magnesium anode to prevent corrosioninner tank with 100 mm puf insulation including cost of gi frame structure, earthing and other required civil work complete all respect as per direction of e/i. 153 solar power system including cost of gi frame structure, earthing and other required civil work complete all respect as per direction of e/i. 154 main lt panel: design, manufacturing, supply installation, testing & commissioning of lt switchgear panels suitable for 433 v, 3 phase, 4 wire, 50 hz power distribution system. the panel shall be indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 swg crca sheet steel, complete with colour coded, heat shrinkable pvc insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. the panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel shall withstand the fault level of 25ka as per single line diagram.a) 1 no. incoming 320a fp 35ka mccb with with o/c, s/c& e/f release, , spreaders & extended roary handle along ct, metering, compelete with all fuses wiring etc and. for 160kva css incomer.b) 1 nos. outgoing 160a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc.c) 1 nos. outgoing 125a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc. c) 8 nos. outgoing 63a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc. 155 emergency cum amf paneldesign, manufacturing, supply installation, testing & commissioning of emergency cum amf panels suitable for 433 v, 3 phase, 4 wire, 50 hz power distribution system. the panel shall be indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 swg crca sheet steel, complete with colour coded, heat shrinkable pvc insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. the panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel shall withstand the fault level of 25ka as per single line diagram. 156 a) 1 no. mains supplyincoming 125a tp 25ka mccb with o/c & s/c release, ct, metering, compelete with all fuses wiring etc.b) 1 no. dg supplyincoming 125a tp 25ka mccb with o/c & s/c release, ct, metering, compelete with all fuses wiring etc. logic control wiring with required relays, timers etc. with trickle/boost battery charger with dc ammeter & voltmeter etc. compelete with all fuses wiring etc and.c) 2 nos. outgoing 100a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc. d) 6 nos. outgoing 63a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc. e) 4 no. outgoing 40a 25ka tp mccb with extended rhom along with o/c & s/c protection, along with ammeter with ammeter selector switch, ct etc. 157 apfc paneldesign, manufacturing, supply installation, testing & commissioning of lt apfc panel as under suitable with incomer bus bar for 433 v, 3 phase, 4 wire, 50 hz power distribution system. the panel shall be indoor, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 swg crca sheet steel, complete coded, heat shrinkable pvc insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. the panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel shall withstand the fault level of 25ka. the panel shall be completed in all respect as per below mentioned boq and.a) 100kvar 10 stage with 160a tp, 25ka mccb incomer with metering &individal mcb/mccb for feeder protection alongwith microprocessor based apfc relay 158 normal floor vertical tpn db (double door)supply installation, testing & commissioning of normal vtpn db suitable for 433 v, 3 phase, 4 wire, 50 hz. the db shall be indoor double door type, sheet metal clad, cubicle, dead front, dust and vermin proof fabricated out of crca sheet steel, complete with colour coded, bus bars and separate earth connection of adequate capacity. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable box/ alley. the db shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel/ db shall withstand the fault level of 10ka as per single line diagram. 159 stilt floor vertical tpn db 4 way (double door) normal supply sor 2018 si no. 1026(c ) +1021+1016a) 1no. incoming 63a (16ka) fp mccbb) 4 nos. outgoing 40a tp mcb (10ka) 160 first &fourth floor vertical tpn db 6 way (double door) normal supply a) 1no. incoming 63a (16ka) fp mccbb) 5 nos. outgoing 40a tp mcb (10ka) si no. 1027 (c )+102+1016 161 second floor vertical tpn db 8 way (double door) normal supplya) 1no. incoming 63a (16ka) fp mccbb) 5 nos. outgoing 40a tp mcb (10ka) si no.1028 © +121+1016+101c) 3 nos. outgoing 32a tp mcb (10ka) 162 third floor vertical tpn db 6 way (double door) normal supplya) 1no. incoming 63a (16ka) fp mccbb) 1 no. outgoing 50a tp mcb (10ka) c) 5 nos. outgoing 40a tp mcb (10ka)si no. 1027 (c )+1021+1017+1016 163 emergency floor vertical tpn db (double door)supply installation, testing & commissioning of emergency vtpn db suitable for 433 v, 3 phase, 4 wire, 50 hz. the db shall be indoor double door type, sheet metal clad, cubicle, dead front, dust and vermin proof fabricated out of crca sheet steel, complete with colour coded, bus bars and separate earth connection of adequate capacity. the incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable box/ alley. the db shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. the panel/ db shall withstand the fault level of 10ka as per single line diagram. 164 stilt, floor vertical tpn db 4 way (double door) emergency supplya) 1no. incoming 40a (16ka) fp mccbb) 4 nos. outgoing 32a tp mcb (10ka)si no. 1026 (c )+1021+1013 165 first, second, thirdfloor vertical tpn db 8 way (double door) emergency supplya) 1no. incoming 63a (16ka) fp mccbb) 2 nos. outgoing 40a tp mcb (10ka) c) 4 nos. outgoing 32a fp mcb (10ka)si no. 1028 (c )+1021+1016+1013 166 fourth floor vertical tpn db 6 way (double door) emergency supplya) 1no. incoming 40a (16ka) fp mccbb) 5 nos. outgoing 32a tp mcb (10ka)si no. 1027 (c )+1021+1013 167 11kv switch gear (incoming cum outgoing vcb panel)supply of single panel (incoming cum outgoing) set 11kv, 500mva indoor type metal clad floor mounted vermin proof horizontal drawout fully interlocked vertical/horizontal isolation vacuum circuit breaker panel board fabricated out of minimum 2mm thick crca sheet as per specifications. the panel shall be complete with all accessories / fitting / wiring like insulated copper busbar, cable termination boxes suitable for upto 3c x 300 sqmm xlpe armoured, aluminium conductor cable for incoming and outgoing feeder, foundation bolts etc. complete as required and as specified below : incoming cum outgoing : 1 set (each consisting of) 168 one (1) nos. 11kv 630 amps. 500mva, 26.3ka for 3sec. electrically/ manually operated draw out type vacuum circuit breaker complete with trip free spring charged closing mechanism, necessary auxiliary relays, control switches, emergency hand trip devices and mechanical on / off indicator etc. one (1) multifunction meter showing all electrical paramaterie volt, ampere, kw, kva, p.f., kwh etc.one (1) digital type ammeter with 11kv cast resin cts for metering (50/25 /5 5a, cl1, 15va) with ass and 2 amp sp mcb.one (1) voltmeter (0 15kv) with vss.one (1) set of phase indication lamps with 2amp sp mcb for protection (red, yellow and blue).one (1) set of red/ green indicating lamp for close and open position.one (1) no. amber indicating lamp for auto trip.one (1) no. clear indicating lamp for trip circuit healthy. one (1) blue indicating lamp for spring charged.one (1) strip heater to prevent absorption of moisture.one (1) set of 3 o/c + 1e/f (with high set) neumerical relay with 3 nos. 11kv resin cast cts 50/25/5 5a, cl 10p10, 15va.master trip relay.trip circuit supervision relayone (1) no. potential transformer 11kv/v3/110/v3 100va burdenone (1) set of 3element 24v dc aux. relay with h/r flag for tripping of transfomerfault ie. oti, wti & buchholz tripping. one (1) set of 3element 24v dc aux. relay with h/r flag for alarm of transfomerfault ie. oti, wti & buchholz alarm. one (1) set of 8 stage 24v dc annunciator with builtin test/accept/ reset push button along with 24v dc hooter. master trip relay.12 window annunciatorauxiliary switch/relay, master trip, anti pumping relay trip circuit supervision relay and other control relays etc. as per requirements.power pack :one (1) set 230v a.c, / 24v dc, 42ah battery backup, power pack to operate atlease 3nos. operation without ac supply. 169 125 kva 11kv / 0.415kv transformer:design, manufacture, supply, installation, testing and commissioning of 11kv/0.415kv, 125kva transformer with percentage impedance 5% (approx.) (without negative tolerance), 3 phase, 50 hz delta/star connected, outdoor, oil filled, onan type transformer, complete with all fittings such as marhslling box thermometers (oti), wti, buchholz relay, off load tapp changer with + 5 % to –12.5%, tapping at the step of 2.5% bi directional roller, diagrams & rating plate & winding temperature indicator, oil temperature indicator, lifting lugs, h. t. cable box/ lt cable box suitable for termination of cable. transformner shall confirm to latest is : 1180 energy efficiensy level i including making of rcc foundation of size suitable for 125kva transformer.complete in all respect. 170 supply and laying of 3 core standered aluminium conductor xlpe (cross linked polyethylene) insulated pvc bedded, galvanised flat steel strip armoured cables confirming to i.s. 7098 (part ii with latest amendments) ii kv grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. the armouring of cable shall be properly connected with earth conductor by clamps etc. pwd sor 2018 si no. 50670 sq. mm 3 core 171 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required dsr 2018 si no. 10.4.170 sqmm 172 supply of 62.5 kva three phase silent dg set comprising of cummins make engine model 4btaa3.3 g11 developing 84 bhp and 62.5 kva, 415 v stamford make alternator mounted on a common base, complete with fuel tank, batteries and leads, residential silencer, standard panel, first fill of lube oil, avm pads, acoustic enclosure 173 amf panel suitable for 62.5 kva dg set 174 pcc foundation mixing ratio 1:2:4 cement, morang, concrete suitable size of dg set 175 gi pipe chemical earthing 50x3000mm complete with back filled compound 176 installation: like unloading & shifting at site, cable aluminium 70x3.5 c 20 meter, control wiring for amf panel, end termination of cabletesting, commissioning withdiesel. ...

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited - Uttar Pradesh

32320462 the work of providing support services in maintenance of candi equipments and breakdown maintenance of all units of 3x210 mw, atps, anpara during the year 2022 2023. 1 overhauling & servicing of limitorque make actuators smb 000 2 overhauling & servicing of limitorque make actuator smb 00 3 overhauling & servicing of limitorque make actuator smb 0 4 overhauling & servicing of limitorque make actuator smb 1 5 overhauling & servicing of limitorque make actuator smb 2 6 overhauling & servicing of limitorque make actuator smb 3 7 overhauling & servicing of limitorque make actuator k 1000 f16 a / k 800 8 overhauling & servicing of limitorque make actuator k 600 f 14 a / k 500 9 overhauling & servicing of limitorque make actuator k 300 g1 / g2 10 overhauling & servicing of limitorque make actuator k 150 f 10 a 11 overhauling & servicing of limitorque make actuator k 60 f 10 a 12 overhauling & servicing of limitorque make actuator k 30f 10 a 13 overhauling & servicing of eemg dc oe 140 c 14 overhauling & servicing ofsiemens 15 overhauling & servicing of auma 16 overhauling & servicing of l 120 20 17 overhauling & servicing of actuator driven damper drive device 18 dismantling & re installation of limitorque make actuator smb 000 19 dismantling & re installation of limitorque make actuator smb 00 20 dismantling & re installation of limitorque make actuator smb 0 21 dismantling & re installation of limitorque make actuator smb 1 22 dismantling & re installation of limitorque make actuator smb 2 23 dismantling & re installation of limitorque make actuator smb 3 24 dismantling & re installation of rotork make actuator k 1000 f16 a / k 800 25 dismantling & re installation of rotork make actuator k 600 f 14 a / k 500 26 dismantling & re installation ofrotork make actuator k 300 g1 / g2 27 dismantling & re installation of rotork make actuator k 150 f 10 a 28 dismantling & re installation of rotork make actuator k 60 f 10 a 29 dismantling & re installation of rotork make actuator k 30f 10 a 30 dismantling & re installation of actuator eemg dc oe 140 c 31 dismantling & re installation of siemens make actuator 32 dismantling & re installation of auma make actuator 33 dismantling & re installation actauator of l 120 20 34 dismantling & re installation of actuator driven damper drive device 35 repairing of actuator drive sleeve unit of m / s rotork make electrical actuators k 1000 / 800 36 repairing of actuator drive sleeve unit of m / s rotork make electrical actuators k 600 / 500 37 repairing of actuator drive sleeve unit of m / s rotork make electrical actuatorsk 300 38 repairing of actuator drive sleeve unit of m / s rotork make electrical actuatorsk 150 / 60 / 30 39 to make hole, threading, milling and machining of stem drive nut as per actuator drive stemfor limitorque make actuators 40 to make hole, threading, milling and machining of stem drive nut as per actuator drive stemfor rotork make actuators 41 full load feed water control valve bf 29 42 full load feed water control valve bf 30 43 low load feed water control valve bf 31 44 low load feed water control valve bf 32 45 bfp a scoop control system 46 bfp b scoop control system 47 bfp c scoop control system 48 super heater spray control valve bf 63 49 super heater spray control valve bf 64 50 super heater spray control valve bf 65 51 super heater spray control valve bf 66 52 re heater spray control vave bf 79 system 53 re heater spray control vave bf 80 system 54 re heater spray control vave bf 81 system 55 re heater spray control vave bf 82 system 56 vane control system of id a 57 vane control system of id b 58 vane control system of fd a 59 vane control system of fd b 60 vane control system of pa a 61 vane control system of pa b 62 burner tilt control system ( corner 1 ) 63 burner tilt control system ( corner 2 ) 64 burner tilt control system ( corner 3 ) 65 burner tilt control system ( corner 4 ) 66 secondary air damper control system ( corner 01 ) 67 secondary air damper control system ( corner 02 ) 68 secondary air damper control system ( corner 03 ) 69 secondary air damper control system ( corner 04 ) 70 mill a control system 71 mill b control system 72 mill c control system 73 mill d control system 74 mill e control system 75 mill f control system 76 fuel firing control system ( corner 1 ) 77 fuel firing control system ( corner 2 ) 78 fuel firing control system ( corner 3 ) 79 fuel firing control system ( corner 4 ) 80 site equipment of scp1 to scp15 81 sequential control system of aph 82 sequential control system of id fan 83 sequential control system of fd fan 84 sequential control system of pa fan 85 sequential control system of bfp 86 annunciation system cp1 to cp12 87 annunciation system power supply 88 acs system power supply 89 furnace draft high left side protection 90 furnace draft high right side protection 91 furnace draft low left side protection 92 furnace draft low right side protection 93 primary air header pressure low protection 94 primary air header pressure very low protection 95 hp heater 5 level control loop 96 hp heater 6 level control loop 97 lp heater 1 level control loop 98 lp heater 2 level control loop 99 lp heater 3 level control loop 100 dm 15 control valve system 101 dm 16 control valve system 102 dearator level control loop 103 minimum recirculation control loop 104 repairing, servicing and reconditioning of hydramotor valves actuator with limit switch assemblies. 105 rewinding, varnishing, servicing and reconditioning ofdefective and burnt solenoid of dw 109 / 110 valve. 106 replacement of various types of actuator diaphragms 107 repairing of defective discrepancy switch 108 repairing of definite time delay relay ( vtt ) . 109 replacement of defective level switch 110 repairing of control relay ( vajc ) . 111 repairing of defective pressure switch. 112 repairing of defective air filter cum regulator. 113 repairing of ac / dc regulated power supply 240vac / 24vdc. 114 welding / cutting / grinding of oil & air pipe line of 16 to 20mm size ( rate given for replacement of pipe line per meter / attending leakage point ) . 115 rewinding / varnishing of defective transformer 110v / 24v, 1 phase. 116 replacement of defective hot air gate power cylinder. 117 repairing of defective retractor assembly. 118 repairing of defective hot air gate solenoid valve. 119 repairing of defective heavy duty cum operated limit switch. 120 repairing of defective hot air gate power cylinder. 121 replacement of defective vane control / burner tilt power cylinder 122 replacement of defective bfps positioned along with its power cylinder and accessories. 123 repairing of defective bfps scoop tube actuator’s positioned along with its power cylinder. 124 replacement of defective / old pu tube / teflon tube of bfpsscoop tube actuator’s 125 repairing of defective hotv solenoid valve.. 126 repairing of defective hotv limit switch. 127 repairing of defective crl / cr relay. 128 repairing of defective boiler manual trip push button cum indicator....

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

30859582 annual operation & preventing, routine & general / normal breakdown maintenance of 132 kv sub station, shrimau under electricity transmission division, hardoi 1 operation, preventive, routine & general / normal breakdown maintenance of 132 / 33 kv sub station, shrimau, hardoi alongwith other associated works, during the period of 1 year. the details as given below: 2 operation of 132 / 33 kv sub station, shrimau ( hardoi ) round o clock in 3 shifts of 08:00 hours each per day by deploying a team consisting of technical person ( 01 no. tg ii / sso with iti in electrical trade with having knowledge of computer application and 01 no. semi skilled helper to assist the tg ii on duty shift ) in each shift ( total 04 nos. shifts 01 no. shift being on rest per day ) by due operation of sub station equipments transformers including d.g. set etc. as per standard practices of upptcl and instructions of higher officers ae / je and clds / alds along with recording of operational activities system information / data message etc. during the period of 01year with all cost of man required for the job. 3 preventive routine & general / normal / emergency break down maintenance of the transformer outdoor / indoor equipments control & relay panels, rtcc panel, acdbs, battery chargers, dcdbs, battery sets etc. at 132 / 33 kv sub station, shrimau round the clock and / or as and when required, by a team consisting of01 no. tg ii / sso with iti in electrical trade and 01 no. semi skilled helper to assist the tg ii & 01 no. line man / technicianas per standard practices of upptcl and instructions of ae / je for the period of 01 year with all cost of men, misc. consumables, t&p etc. required for the job except the spares / items materials / equipments, which shall be provided by department. 4 daily general cleaning and maintenance / up keep of control room, associated office, carrier room, battery room, control room building etc. by brooming & mopping alongwith cleaning of associated toilets including brooming of cc roads / floors trench covers and scraping of unwanted growth in between joints of cc roads at 132 / 33 kv sub station, shrimau ( hardoi ) and premises as per details annexure d.by deploying required man power and 01 no. sweeper during the period of 01 year with all cost of man toiletries, misc. consumable t&p etc. required for the job ( 01 job for each month ) 5 regular maintenancefor 01 year of flower pots, lawn trees, shrubs, hedges, ground cover, flower beds in lawn, by deputing required no. of well experienced gardners including weeding out of all undesired growths. watering trimmings, forking, making loose soil around plant, lawn etc. including replacement of aired plants, grass with fresh plant of same verity including costof cowdung manure and its spreading with all men and material to complete the job as per directionn of the engineer incharge. 6 grass cutting of switchyard by scraping of grass, bush wood, shrubs & plants etc. weeding out of wild growth roots, seeds etc. including of small wild trees if any at sub station premises and disposal of all the removed vegetation, rubbish & garbage etc. by throwing it outside of sub station boundary 4 times in year & chemical spray 01 times in a year with all cost of man, consumables, t&p etc. required for completion of job. 7 cleaning of cable trenches including opening of trench covers from trenches before starting of work, removing of earth deposits nets, other foreign material from layed control cables & their cable racks and cleaning of cable trenches from top to bottom accordingly and releasing of mud stone / bricks pieces, other foreign material from trenches and throwing them away far from switchyard boundary then re placing of opened trench covers on their proper place on the trenches alongwith all associated works....

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

30859541 transportation of 40 mva 132 / 33 kv t / f from 132 kv sub station, mskp ( meharam singh ka purva ) , dist. kanpur to 132 kv s / s asha ( district hardoi ) including its loading, unloading, alongwith dismantling, dragging, shifting, installation and associated workat 132kv s / s asha under etd hardoi 1 partial dismantling of the accessories ofold 132 / 33kv 40 mvat / f. draining out of transformer oil upto required level in 450 ltr capacity oil drums / tank, removal of conservator tank, all bushing turrets, cooling fans, marshalling box, radiators after draining of radiator oil etc, fixing of blanking plate on the radiators, all pipe line, conservator tank, turrets etc. with proper stacking. blanking plate bolts and nuts shall be provided by the contractor at his own cost at 132kv s / s, mskp ( meharam singh ka purva ) dist. kanpur. 2 shifting of main tank of 132 / 33kv 40 mvat / f, from place of storage to place of loading on trailor up to 20 meter distance ( approx. ) at 132kv sub station, mskp ( meharam singh ka purva ) dist. kanpur. 3 additional shiftingfor every 5 mtr. 4 loading of 132 / 33kv, 40 mva t / ftransformer tank including all accessories on trailor / truck which includes jacking the t / f tank for placing wooden sleeper under the tank and simultaneously lifting the tank by jacking and placing sleeper continuously under the tank till wooden platform comes in alignment of trailor bed and then shifting the tank from wooden platform to trailor bed. removal of rails etc. from under the tank proper tightening of main tank on trailor bed with help of wire rope and turn buckle for safe transportation . 5 safe carriage of 132 / 33kv, 40 mva t / f, tank and accessories on suitable capacity of trailor / truck to be arranged by the contractor at his own cost, transit insurance shall be got done by the contractor and payment shall be done extra on presentation of bill. carriage of 40 mva t / f tank along with accessories will be done from 132kv sub station, mskp ( meharam singh ka purva ) dist. kanpur to 132kv sub station, asha route selection to be done for avoiding electrified railway crossing. ( approx. distance 160 km. ) 6 proper packing of hv bushings of 40 mva t / f at 132kv sub station, mskp dist. kanpur for safe carriage. 7 unloading of 132 / 33kv, 40 mva t / f, tank and including all accessories from trailor / truck and their proper stacking at designated place at 132 kv sub station, asha ( hardoi ) . the job includes opening of laces, jacking the t / f tank for placing rails under the tank, shifting it to wooden sleepers platform to be prepared adjacent to trailor, removing the rails from under the tank upto ground level. 8 shifting of main tank of 40 mva 132 / 33kv transformer upto 20 meter distance from unloading place towards plinth including turning of the transformer tank, as required alongwith all associated work at 132kv sub station, asha ( hardoi ) 9 additional shiftingfor every 5 mtr. 10 safe carriage of storage oil tank of 50 kl including loading, un loading & carriage upto the site of approx distance 30 km from 220 kv sub station, hardoi to 132 kv sub station, asha 11 shifting of oil filled main tank of 132 / 33 kv 40 mva t / ffrom the plinth up to 35 meter ( approx ) distance including turning of tank if required, including all t & p and other associated works to complete the job satisfactorily. 12 additional shifting of main tank of the above t / f in addition to sr. no.1 . ( 1 job each for each additional shifting of 5 meter ) 13 complete drain out of transformer oil from 40 mva t / f tank into empty oil drum / storage tank. 14 replacement of all gaskets including the top of t / f by providing and fixing new gaskets as per existing size made of rubberised cork sheet made of kotika / turboze / nu cork brand grade 07+a43 15 replacement of all ring shaped washer placed on air release valve of all radiators by providing new gasket as per existing size made of special plastic teflon washer of suitable size 28 to 30mm. 16 complete erection of 132 / 33 kv 40 mva t / f .the erection of radiator, conservator tank, all bushings, turrets, bucholz relay, connecting pipe lines, cooling fans, motor drive mechanism of tap changer jumpering of hv & lv side etc.filling & topping up of the t / f oil in tank, radiator, all pipe lines, conservator tank etc. and attending the oil leakages if any and all other associated works for satisfactory completion of work. all t & p shall be provided. 17 overhauling the diverter switch and bucholz relay after removing transformer oil and dirty transformer oil from its chamber .filling the fresh centrifused transformer oil.checking proper operation of bucholz relay. 18 cleaning of core and winding by fresh transformer oil and remove the sludge from bottom 19 creating the vaccuum inside the main tank for the period of 12 hrs and filling of centrifusing oil setup to core and winding , conservator &radiator. 20 carriage of 10 number fresh transformer oil from 220kv s / s hardoi to 132 kv s / s asha distance approx 30kms ( approx ) .loading of 10 number filled oil drums at 220kv s / s hardoi and unloading the same at 132kv s / s asha store to complete the job satisfactory. 21 centrifuging of oil in main transformer tank un interrupted till the desired bdv valve of the oil is achieved including recording all the parameters hourly such as temperature, vacuum, material, centrifuging machine and t & p. 22 complete earthing of 40 mva t / f with 75x10mm / mm flat as per standard practice at two points 23 earthing of main tank of the t / f, control panel, marshalling boxes etc. shall be earthed as per standard practice. 24 delta earthing consisting of fabrication of 03 nos. 03 meter long electrod ( 40mm dia ms bar ) its placing 70mm below ground level and connection of all 03 electrod with 75x10 mm ms flat and connecing the same at 02 places earthing of t / f nutural with flat and angels. 25 earthing of t / f neutral with 75x10 mm. ms flat connecting with delta at 2 points including painting and other associated works. 26 jumpering of the 40 mva t / f. 27 hv side with single acsr panther conductor. 28 lv side with acsr panther conductor. 29 erection of 40 mva t / f control and relay panel with all required work. 30 laying of following sizes of control cable in the cable trench from control relay panel to various equipment / marshalling boxes / jb etc. in switchyard as per cable schedule, its saddling at every 75mm. distance with ms saddles of size 25x3mm. including carriage of cable drum from store to laying site & shifting back to store and all other associated works to complete the job satisfactorily as per technical specification. 31 6 x 2.5 mm. 32 4 x 2.5 mm. 33 2 x 2.5 mm. 34 termination of 40 mva, 132 / 33 kv t / f bay control cables in control & relay panel and yard side equipments with proper ferruling as per cable schedule including making necessary holes in the glands plates or box wherever required, the job satisfactorily as per technical specification. 35 painting of transformer after removal of rust / dust then painting them with one coat of red oxide then two coat with smooth gray of isi mark paint. 36 painting of newly erected ms flat following with 01 coat red oxide and 02 coat with bus green isi mark paint complete with its ms flat & vertical support. 37 ms flat 50x6 mm 38 ms flat 75x10mm 39 supply, installation & commissioning of led street light luminaries 120 watt aluminum die cast ( gst extra ) . transportation upto site, insurance etc. and any other job requested to properly execute the complete work. 40 retrofiiting and commisionning of 2 no. abt meters and complete termination of cable using suitable sizes of cable gland at both ends....

irrigation and water resources department - Uttar Pradesh

30655133 bids are invited for 1 supply & replacement of 33kv oil immersed outdoor type ct dual core dual ratio 300 150/1 1a core 1 class 1 & core 2 class 5p10. the job incldes the dismantling of existing ct & installation of new ct with all connection temination etc. complete in all respect , 2 supply & replacement of 33kv oil immersed outdoor type ct dual core dual ratio 150 75/1 1a core 1 class 1 & core 2 class 5p10. the job incldes the dismantling of existing ct & installation of new ct with all connection temination etc. complete is all respect , 3 shifting of c&r panel from existing place to other place including dismantling of same and opening of all existing connections & shifting of c&r to other place & installation & termination of all cables etc at new location , 4 supply & laying of control cable from ct to c&r panel installed at new location 6 core 2.5 sqmm copper armoured cable , 5 supply & laying of control cable from pt to c&r panel installed at new location 6 core 2.5 sqmm copper armoured cable , 6 supply & laying of control cable from 33kv vcb to c&r panel (a.c. supply) installed at new location4 core 2.5 sqmm copper armoured cable , 7 supply & laying of control cable from 33kv vcb to c&r panel (dc supply) installed at new location 2 core 2.5 sqmm copper armoured cable , 8 supply & laying of control cable from 33kv vcb to c&r panel (control connetctions) installed at new location12 core 2.5 sqmm copper armoured cable , 9 supply and laying of 3 core 70sqmm standered aluminium conductor xlpe (cross linked polyethylene) insulated pvc bedded, galvanised flat steel strip armoured cables confirming to i.s.7098 (part ii with latest amendments) iikv grade. the armouring of cable shall be properly connected with earth conductor by clamps etc. , 10 horizontal direction drill at 1mtr , 11 supply & laying of dwc pipe dia 100mm with all socket etc. complete in all respect , 12 cable jointing of 11 kv grade 3 core 70sqmm xlpe insulated armoured cable with suitable cable termination using raychem/birla 3m/mecp kits including all accessories i.e. sockets, lugs, gland etc as required but without cable box. , 13 supply & fixing of transformer protection relays (oti, wti & wti). the relays shall be manual reset type with hr flag control supply voltage shall be as per site requirement. the job includes the making necessary cutout in existing panel and fixing of relays along with all required wiring testing etc. complete in all respect , 14 supply & burying of safe earthing electrode t 39 zn. zinc coated, length 3000mm, outer pipe 76.3mm x 3.2mm inner pipe 42.4mm x 2.6mm, terminal dia 12mm, coating 80 100micron filled with crysteline conductive mixture (ccm) havinbg anti corrosive & conductive properly with 50kg activated soil (bfc) capable of reducing the soil restivity with good mixture of retaining capacity and one earthing lead of 20 x 3 g.i. strip upto switch board with 30cm square c.i. frame with hinged cover & masonary housing. , 15 supply and burring of safe earthing electrode t 39 cu copper coated, length up to 3000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal dia 12mm, coating 80 100 micron filled with crystalline conductive mixture (ccm) having anti corrosive & conductive property with 50 kgs activated soil (bfc) capable of reducing the soil resistivity with good mixtureof retaining capacity along with 30 cm square c.i. frame with hinged cover & masonry housing. , 16 supply & laying of 32 x6 mm g.i. strip from earth electrode directly in ground as required complete in all respect. , 17 supply & laying of 50 x6 mm copper strip from earth electrode directly in ground as required complete in all respect. , 18 supply,instattion,testing and commissioning of ese lightning protection the works includes with lightningprotection system,lighning counter,earth electode,earth enhancing compound,hdpe chamber,busbar ms mast and earth strip complete in all respect. , 19 supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. , 20 supply, installation, testing and commissioning of 5mva onan transformer 33 kv/ 11v, 3 phase, 50 hz delta/star connected, outdoor, oil filled, completewithall fittings such as thermometers, buchholz relay, with off circuit tapp changer + 5 % to –15%, tapping at the step of 1.25% with rating plate & winding temperature indicator & protection , oil temperature indicator & protection, lifting lugs, h. t. cable box/ lt box etc. , 21 supply, installation, testing and commissioning of one set 33kv, 1500mva indoor type metal clad floor mounted vermin proof horizontal drawout fully interlocked vertical isolation vacuum circuit breaker panel board fabricated out of minimum 2mm thick crca sheet as per specifications. the panel shall be complete with all accessories / fitting / wiring like insulated copper busbar, cable termination boxes suitable for 3c x 300 sqmm xlpe armoured, aluminium conductor cable for incoming and outgoing feeder, foundation bolts etc. complete as required and as per attached specified , 22 supply and laying of 3 core 240sqmm standered aluminium conductor xlpe (cross linked polyethylene) insulated pvc bedded, galvanised flat steel strip armoured cables confirming to i.s.7098 (part ii with latest amendments) iikv grade. the armouring of cable shall be properly connected with earth conductor by clamps etc. , 23 cable jointing of 33 kv 240sqmm grade xlpe insulated armoured cable with suitable cable termination using raychem/birla 3m/mecp kits including all accessories i.e. sockets, lugs, gland etc as required but without cable box. , 24 supply, installation, testing and commissioning of 11kv, incoming vcb feeder panel 26.3ka indoor type metal clad floor mounted vermin proof horizontal drawout fully interlocked horizontal isolation vacuum circuit breaker panel board fabricated out of minimum 2mm thick crca sheet as per specifications. the panel shall be complete with all accessories / fitting / wiring like insulated copper busbar, cable termination boxes suitable for upto 3c x 300 sqmm xlpe armoured, aluminium conductor cable for outgoing feeder, foundation bolts etc. the panel shall be installed along with existing 11kv vcb panel and prices quoted with coupling bus bar to be connected the above panel with existing vcb panel along with all alignemet & conection. the panel shall be scada compitable and shall be provided with suitable metering to measure import / export energy data on scada also. the job shall be completed as per site requirement and as per attached specification. , 25 supply of single panel(1 incoming + 5 outgoing + 1 bus coupler vcb panel) set 11kv, 500mva indoor type metal clad floor mounted vermin proof horizontal drawout fully interlocked vertical/horizontal isolation vacuum circuit breaker panel board fabricated out of minimum 2mm thick crca sheet as per specifications. the panel shall be complete with all accessories / fitting / wiring like insulated copper busbar, cable termination boxes suitable forupto 3c x 300 sqmm xlpe armoured, aluminium conductor cable for incoming and outgoing feeder, foundation bolts etc. complete as required and as per attached specification , 26 overhauling of 500kva 11/.415kv distribution transformer , 27 design and manufacturing of moving trollysuitable for 500kva 11/.415kv transformer , 28 supply & installation of 33kv terminal gantry with structure to receive 33kv power from existing 33kv bus available already in switchyard. the job includes all g.i. structure, steel sections xross arms etc. with foundation, painting of pole and including pin & string insulator, suppots hardware etc. , 29 supply, erection, testing and commissioning of 33 kv 630 amps triple pole isolator with earthing heel as per latest is:9921 (pt i to v) , 30 supply, erection of 33 kv current transformer single phases conforming to is:2705(pt.i to iv) a) core 1 (metering) 150 75/1a class 0.2, 20va b) core 2 (protection) 150 75/1a class 5p10, 20va , 31 supply, erection, testing and commissioning of 33kv 800 a, 1250 mva out door type as per technical specification enclosed vacuum circuit breaker complete as per latest is:13118. , 32 erection of 30kv ,10ka lightening arrestor with insulating base and surge counter as per latest is:3070 part i/1985 ( latest version) , 33 supply, erection, testing and commissioning of control & relay panel for single transformerwith suitable protection and controls for all isolators & vcb. the panel shall be scada compitable and shall be sujitable to operated from remote control station , 34 terminal connector to receive from 33kv line (terminal gantry) suitable for acsr conductor , 35 terminal connector to receive to bus isolator suitable for acsr conductor , 36 terminal connector for lightning arrestor suitable for acsr conductor , 37 terminal connector for ct suitable for acsr conductor , 38 terminal connector for vcb suitable for acsr conductor , 39 erection of t clamp for acsr conductor , 40 galvanised structure for lightning arrestor with all section cross arm etc. , 41 galvanised structure for line isolator with all section cross arm etc. , 42 galvanised structure for current transformer with all section cross arm etc. , 43 galvanised structure for vaccum circuit breaker with all section cross arm etc. , 44 acsr conductor 0.2 inch(nominal area 200 sqmm) , 45 marshalling box for ct , 46 misc itms other than above items , 47 cordination, engineering & misc job for complete substation , 48 supply, erection, testing and commissioning of battery charger float cum boost along with input & output mcbs,amp, volts meter, interconnections etc. power supply 230 v, 1 phase, 50 hz ± 10%. charger troubleannunciation shall be provided through led. , 49 supply erection testing & commissioning of 100ah battery bank capacity consisting of 12nos. 2v tubular cell alongwith mounting cabinet and copper connection leads etc. , 50 pre noc & noc after completion of work from statuary authority is essential for every service as required. viz.electrical panels, transformers from directorate of electrical safety , state government / competent authority. , 51 supply and laying of 400sqmm 3.5 core aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. , 52 supply and laying of 240sqmm 3.5 core aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. total quantity : 1...

Council Of Scientific And Industrial Research - Uttar Pradesh

30646594 supply installation testing commissioning sitc of new control panel with wiring and updating the panels ( 320kva dg sets at garden block ) . 1.01 the pand will comprised with:1 02 mccb 600aimip 1 03 control relay 1 04avm meter 1 0x control sp mcd ems koel safety unit 1.07 harness 1:08 indicating lamp 1 09 busbar 1.10 selector switch 1.11 panel box 1.12 copper amoured cable 1.13 harness for dg set...

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

30602738 erection of structure and equipment for construction of 01 no. 132 kv bay ( for 132 kv lalukheri sub station ) at 220 kv sub station badhaikalan under electricity transmission division, muzaffarnagar =2 erection of auxiliary structure consisting of bbl, bti, bct, alp etc. including all allied works complete in all respect. department shall provide structure & nut and bolts etc. the works shall be strictly carried out as per drawing & technical specification. 3 erection of equipment as per instruction manual of various equipments and technical specification including shifting of material, equipments from store to erection site including all their associated work with the help of crane provided by the contractor at their own cost for completion of the job satisfactorily: 3.1 145 kv cb with structure 3.2 145 kv cts 3.3 145 kv pts 3.4 145 kv bus isolator 3.5 145 kv line isolator 3.6 145 kv tandem isotator 3.7 120 kv la 3.8 145 kv control & relay panel 3.9 145 kv ct & pt junction box 4 inter connection of equipment and bus including cutting, bending of conductor & jumpering clamping along with all other associated works to complete the job satisfactorily as per drawing & technical specification with 02 main & 01 transfer bus to complete the 132 kv bay in all respect. 5 laying and dressing of control cable in trenches after removal of trench cover as per cable schedule including clamping with 25x3mm al. strip and gi nut and bolts including cutting, peeling of the control cable. 5.1 2x2.5 sq. mm. 5.2 4x2.5 sq. mm. 5.3 6x2.5 sq. mm. 6 termination of cables laid above as per cable schedule including making necessary holes in panel base plate or junction box as per site requirement. fixing of cable glands of appropriate size. supply & providing ferrules on each core of cable & its termination at both ends and all other associated work. 6.1 2x2.5 sq. mm. 6.2 4x2.5 sq. mm. 6.3 6x2.5 sq. mm. 7 earthing of structures and equipments cutting, straightening bending, laying 700 mm. below in side ground and above ground of following size of ms flat for earthing of auxiliary structure, equipment structure including welding with main earthmat and with object to be earthed, excavation of trenches, its back filling, painting and all other associated works as required to complete the works satisfactorily excluding cost of material. 7.1 ms flat of size 75x10 mm 7.2 ms flat of size 50x6 mm 7.3 ms flat of size 25x6 mm 8 earthing of 120 kv las with 75x10 mm ms flat after making rectangular configuration along with six nos. ( 3 meter length ) 40 mm dia m.s. electrodes as per drawing & technical specification. 9 providing & fixing of phase plate ( r, y, b phase ) of 02 mm thick aluminum sheets of size 5 dia covering of 3 m hip / mdf retro reflected sheet in single piece with all mounting with gi nut and bolts. 1 set comprises of r, y, b phase plates....

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

30433525 tender for work of erection of 132 kv line bay with all assoicated works including supply of material for bay construction at 132 kv s s nagina for 132 kv nagina sherkot line under electy trans division dhampur t part awork 2 1) erection of main auxiliary structure lattic type and auxiliary structure.a) shifting of all material, equipment from storeto work site. 3 b) erection of main auxiliary structure and lattic type s/s structures for installing of atms. xpm.ymm .btm.axm.bbl.bit. bct.alp.abl. etc. the job consist of erection of structure as per drawing with the help of g.i. nut & bolt, flat, spring washer, matching the hole, cutting and matching of member if required including cost of all men and t&p excluding g.i. structure nut & bolt toupon foundation and its proper tightning. 4 2) erection of 145 kv equipmenta) 145 kv sf 6 circuit breaker 5 b) 145 kv bus isolator/ line isolators /tandam isolators 6 c) 145 kv current transformer/potential transformer 7 d) 145 kv post insulator 8 e) 120 kv lightning arrestor with search counter 9 f) 145 kv ct/pt junction box 10 g) 132 kv line control/relay panel/ panel 11 3) stringing of 132 kv jackbus bar and jumpers and extension main bus bar/ transfer bus bara) stringing of 3 phase main/transfer bus bar 132 kv bus with moose/ panther conductor length of 12 meter andas per side requirement mentioned below. the work include cutting and bending of conductor, fixing of single/ double bolted type tension fitting/ suspension. hoisting of disc insulator and shifting of material from erection site to work site and all other associated work to complete the work. 12 b) jumpering, interconnection of equipment with specified conductor of various 132 kvequipments with main/transfer/jack transfer bus bar of acsr moose/ zebra/ panther conductor. the work includes cutting and bending of conductor in proper shape, clamping with the help of the clamps and all associated work to complete the work at 132 kv line bay at 132 kv s/s nagins main/transfer bay. 13 4) cable laying and termination of 132 kv yarda) laying of following size control cables in trench/cable tray from control room equipments to 132 kv cb, ct, tf./ptand their junction box in 132 kv switch yard as per cable schedule, including carriage of cable drums from store to work site and all associate worki) 2 corex2.5 mm sq 14 ii) 4 corex2.5 mm sq 15 iii) 6 corex2.5 mm sq 16 b) termination of control cable per core per end 17 5) earthing of equipments of 132 kv yarda) cutting, strenghting, bending and laying 700 mm/500mm below inside ground and above ground of following size ms flat of earthing of main and auxiliary structure and equipment including welding with main earth mat and with object to be earthed excavation trenches, its back filling painting and all other associated work. excluding the cost of m.s. flat.i) 75x10 mm 18 ii) 50x6 mm 19 b) making of delta earthing of la ofnew line baybyfabrication of 6 no. 3 mts. m.s. rod 40 mm dia electrodes its placing inside the ground and connecting all 6 nos. electrodes with 40 mm m.s. round laying around as per drawing. painting and jointing with 40 mm m.s. round/ 75x10mm ms flatlaying around as per drawing, pain the joints with black japan paint of good quality after proper cleaning of joint by wire brush 20 c) laying of m.s. round 40mm diaearth math fornew line bay byfabrication of 32 no 6 mtrs and laying intrenches at depth800 mm bleow ground level including dap/cross jointing by m.s. welding electrodes and connecting all19 no with 16 no 3 mts vertical electrodes with 40 mm m.s. round excavation and back filling etc. painting and jointing with 40 mm m.s. roundas per is specification & drawing, paint the joints with black japan paint of good quality after proper cleaning of joint by wire brush 21 d) fabrication of 3 mtr long electrode from 40 mmm.s rod having 150 mm log conical shape and its piercing vertical inside the ground with top 800 mm below ground level and its welding with earth mat 22 6) providing and fixing of name plate made of 02 mm thick aluminium sheets with covering of 3hp retro reflective sheeting of size 300mmx150mm.plate to be fixed with the help of nuts & bolts of already installed equipment’s structure. as per sample. 23 7) providing & fixing of phase plateequipment (r,y,b phase of 02mm thick aluminium sheets of size 5” dia covering of 3m hip/mdg retro reflected sheet in single piece with all mounting with gi nut and bolts after opening of old rusted and damaged phase plate. 24 sub total 11) supply of bolted type single tension fitting formoose conductor with turn buckle for 132 kv main bus suitable for each disc stringing 1x10 no. 120kn disc insulator with hardware fitting d shackle, socket ball, hook, yoke plate, clevis, tension clamp as per technical specification. 25 2) supply of bolted type single suspension fitting for moose conductor without turn buckle for 132 kv main 3bus suitable for each disc stringing 1x9 no. 70 kn disc insulator with hardware fitting d shackle, socket ball, hook, yoke plate, clevis, tension clamp as per technical specification. 26 3) supply of bolted type single tension fitting for pantherconductor with turn buckle for 132 kv transfer bus suitable for each disc stringing 1x10 no. 120 kn disc insulator with hardware fitting d shackle, socket ball, hook, clevis, tension clamp as per technical specification. 27 4) supply of bolted type single suspension fitting for pantherconductor buckle for 132 kv transfer bus as per technical specification. 28 5) 132 kv isolator horizontal/vertical clamp for panther conductor made of aluminum alloy lm 6 with nut bolts and washer as per technical specification. 29 6) pg clamp made of aluminum alloy lm 6 suitable for moose to moose conductor with 4 no 16x75/90 mm dia. hdg nut & both and washer as per technical specification. 30 7) pg clamp made of aluminum alloy lm 6 suitable for moose to panther conductor with 4 no 16x75/90 mm dia. hdg nut & both and washer as per technical specification. 31 8) pg clamp made of aluminum alloy lm 6 suitable for panther to panther conductor with 4 no 16x75/90 mm dia. hdg nut & both and washer as per technical specification. 32 9) 132 kv post insulator clamp suitable for panther conductor as per technical specification. 33 10) sorting, counting as per bom and proper loading ofmain auxiliary structure and lattic type s/s structures in truck at electricity febrication unit, nani, allahabad. (weight 20 mt approx.) 34 11) safe carriage of above loaded structure from efu, naini allahabad to 132 kv s/s nagina & sherkot. (distance 700 kms. approx.) 35 12) unloading of structure/tower parts from truck and its proper stacking at 132 kv s/s nagina & sherkot. sub total 2 ...

Indian Air Force - Uttar Pradesh

29841528 bids are invited for relay 24v dc108a (q3) , control relay (aux contractor) (q3) , phase sequence relay (q3) , bridge rectifier (q3) , relay socket type (q3) ,overload relay (q3) , selector switch (q3) total quantity : 23...

Indian Railway - Uttar Pradesh

29583179 supply of three phase network control relay rangethree phase network control relay range,three phase network control relay range 300 430 v, relay name rm17tu00 , parameter phase sequence under voltage and phase failure protection.make schneider / telemecanique / siemens / abb...

Northern Coalfields Limited - Uttar Pradesh

29435684 bids are invited for 3tf3200 oa..01 contactor, 16a coil 110 / 220 / 240 / 415v , 3tf4422 oa..01 contactor, 32a coil 110 / 220 / 240 / 415v , 3tf4602 oa..01 contactor, 45a coil 110 / 220 / 240 / 415v , 3tf4702 oa..01 contactor, 63a coil 110 / 220 / 240 / 415v , 3tf5102 oa..01 contactor, 140a coil 110 / 220 / 240 / 415v , 3tf5502 oa..01 contactor, 300a coil 110 / 220 / 240 / 415v , 3tf5602 oa..01 contactor, 400a coil 110 / 220 / 240 / 415v , 3tx4010 2a auxiliary contact 3tf / th30 / 31 / 32 / 33 , 3tx4001 2a auxiliary contact 3tf30 / 31 / 32 / 33 , 3ty7561 1k auxiliary contact 3tf46 57 1no+1nc , 3ua5500 2c relay for mounting on 3tf44 / 45 / 34 / 35, 16 25a , 3ua5500 2d relay for mounting on 3tf44 / 45 / 34 / 35, 20 32a , 3ua5800 2ez1 relay for mounting on 3tf46 / 47 / 48 / 49, 25 40a , 3ua5800 2fz1 relay for mounting on 3tf46 / 47 / 48 / 49, 32 50a , 3ua5800 2cz2 relay for mounting on 3tf477, 16 25a , 3ua5800 2dz2 relay for mounting on 3tf477, 20 32a , 3ua5800 2fz2 relay for mounting on 3tf477, 32 50a , 3ua5800 2vz2 relay for mounting on 3tf477, 57 70a , 3ua5830 5d relay for mounting on 3tf50, 95 120a , 3ua6230 5c relay for mounting on 160 250a , 3sb1401 2wz3 led pilot light ac / dc 42 240v red , 3sb1402 2wz3 led pilot light ac / dc 42 240v green , 3sb1403 2wz3 led pilot light ac / dc 42 240v amber , 3sb1407 2wz3 led pilot light ac / dc 42 240v yellow , 3sb1404 2wz3 led pilot light ac / dc 42 240v blue , 3sb0801 8aa push button green actuator 1no start , 3th82440b.. auxiliary contactor 4no 4nc, 230vac , 3sb12001ac20 mushroom actuator , 3th8040 oamo auxiliary control relay 220vac , 7pu22402bn sicont electronic timer on delay 220vac , 7pu1540 1bn21oz electronic timer off delay 220vac , 3th8031 oamo auxiliary control relay 220vac , ns4ncl hrc fuse link 4a , ns2ncl hrc fuse link 2a , ns6ncl hrc fuse link 6a , sm20h fuse holder type nsh fron connection , sm 32h moulded fuse holder 415v, 32a , sm 63h moulded fuse holder 415v, 63a , 3ua5200 1c relay for mounting on 3tf30 / 31, 1.6 2.5a , 3ua5200 1k relay for mounting on 3tf32 / 33, 8 12.5a , 3ua5200 2b relay for mounting on 3tf32 / 33, 12.5 20a , 3ua5000 1g relay for mounting on 3tf30 / 31, 4 6.3a , 3ua5000 1e relay for mounting on 3tf30 / 31, 2.5 4a , 3tf4922 oaza01 contactor 85a coil 110 / 220 / 240 / 415 , 3st1400 2rq08 ammeter selector 0 l1 l2 l3 , 3tf5302 oa..01 contactor 205a coil 110 / 220 / 240 / 415 , 3tf5002 oa..01 contactor 110a coil 110 / 220 / 240 / 415 , 3sb1200oa01 push button with 2no+2nc , 3na1013 fuse hrc 3na 1013 16a , 3na1001 fuse hrc 3na 1001 32a , 3na1018 fuse hrc 3na 1018 63a , 3na1227 fuse hrc 1227 250a , 3na1332 fuse hrc 3na1332 400a , 3na1224 hrc fuse 160a , ns32ncl hrc fuse link 32a , ns16ncl hrc fuse link 16a , d 2012 / 4 52cs breaker control switch 3pos 4p, 16a, 220vd , d 2012 / 4 64 neutral displacement relay sp 1, 4to24v , d 2012 / 4ct600 resin cast ct 2core 600 / 1 / 1 15va total quantity : 1...

Indian Institute Of Technology - Uttar Pradesh

29423497 tender for repairing and replacement of defective wire , dlp, switch/socket, led fitting etc at nl 1 wave and beem lab , 103, old sac c block, jee/gate 102 , 104 and 105 etc and other labs in academic area on complaint basis, ms conduit (isi marked), pvc conduit and accessories, pvc conduit and accessories, frls pvc insulated copper conductor stranded flexible wire i/c control cables, cable raceway floor/wall mounted and accessories, modular switch & socket, metal clad industrial socket, cat 6 cable, cable glands, crimp patch cord, protection device (mcb/rccb/db/elcb), mccbs, power contactor, surge protection dm , panel accessories, selector switch, auxiliary relays, led/metal halide/fluorescent internal lighting fixture, external lighting fixture, emergency lighting/ exit sign boards, ceiling fan (isi marked & bee rated 5 star), paint, advance lighting protection system (early streamer emission type), gi pipe, main lt panels/ mcc panel, air circuit breaker, surge voltage protection, earth fault module, protection relays, c.ts and pts, digital meters, change over switch, indicating lamps, power capacitors, automatic power factor correction relay/controller, sealed maintenance free batteries, battery charger, cable trays (factory fabricated/overhead & floor raceways, hdpe underground cable duct, insulation mats, smoke/heat detectors, manual call point, response indicators,m fire exit signs, fire control panel, speaker / hooter, occupancy sensors/ movement sensor, flush type switch /socket, fuse switches unit / switch fuse unit /hrc fuse, exhaust fan, xlpe insulated ht cables, cable lug, lamp holder (brass), telephone wires/telephone cable / jelly filled telephone cables, telephone tag blocks, telephone outlet, gi raceways, pvc raceways, electronic ballast, dlp plastic trunking legrand, geysers, tower light, ht/lt transformers, ht sf 6 circuit breakers/vcb, programmable logic controller(plc), earthing (chemical earthing) plate earthing, earthing (chemical earthing) plate earthing, 11 kv ht panel i/c relay, control relay panel, lightning arrestor, temp. gauge, gate valve, electrical backup, pvc tankpvc tank, thermostat, flat collector plate, s.s sheet, s.s sheet, alternator, dg set, makes of accessories of ht / lt panel / transformers, bus trunking, ht panel 11 k, ht panel 11 k, etc ...

Electrical Division - Uttar Pradesh

28479851 repairing replacement of electrical installation of vacant houses 1 ms conduit (isi marked) 2 pvc conduit and accessories 3 pvc/xlpe insulated aluminium/copper conductor armoured/unarmoured mv cable upto 1100 v 4 frls pvc insulated copper conductor stranded flexible wire i/c control cables 5 cable raceway floor/wall mounted and accessories 6 modular switch & socket 7 metal clad industrial socket 8 cat 6 cable 9 cable glands 10 crimp patch cord 11 protection device (mcb/rccb/db/elcb) 12 mccbs 13 power contactor 14 surge protection devices 15 panel accessories 16 selector switch 17 auxiliary relays 18 led/metal halide/fluorescent internal lighting fixture 19 external lighting fixture 20 emergency lighting/ exit sign boards 21 ceiling fan (isi marked & bee rated 5 star) 22 paint 23 advance lighting protection system (early streamer emission type) 24 gi pipe 25 main lt panels/ mcc panel 26 air circuit breaker 27 surge voltage protection 28 earth fault module 29 protection relays 30 c.ts and pts 31 digital meters 32 change over switch 33 indicating lamps 34 power capacitors 35 automatic power factor correction relay/controller 36 sealed maintenance free batteries 37 battery charger 38 cable trays (factory fabricated/overhead & floor raceways 39 hdpe underground cable duct 40 insulation mats 41 smoke/heat detectors 42 manual call point 43 response indicators 44 fire exit signs 45 fire control panel 46 speaker / hooter 47 occupancy sensors/ movement sensor 48 flush type switch /socket 49 fuse switches unit / switch fuse unit /hrc fuse 50 exhaust fan 51 xlpe insulated ht cables 52 cable lug 53 lamp holder (brass) 54 telephone wires/telephone cable / jelly filled telephone cables 55 telephone tag blocks 56 telephone outlet 57 gi raceways 58 pvc raceways 59 electronic ballast 60 dlp plastic trunking 61 geysers 62 tower light 63 ht/lt transformers 64 ht sf 6 circuit breakers/vcb 65 programmable logic controller(plc) 66 earthing (chemical earthing) plate earthing 67 octagonal pole 68 11 kv ht panel i/c relay 69 control relay panel 70 lightning arrestor 71 temp. gauge 72 gate valve 73 electrical backup 74 pvc tank 75 thermostat 76 flat collector plate 77 s.s sheet 78 ht/lt cable joints (straight through/outdoor/indoor) 79 alternator 80 dg set 81 makes of accessories of ht / lt panel / transformers 82 bus trunking 83 ht panel 11 kv 84 bus duct ...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

28458948 annual maintenance of vcb/ocb annual maintenance of vcb/ocb under eudc jhansi , 1 supply of o/c+e/f relay of 33 kv control & relay panel . ( relay make crompton ) , 1 ( a ) replacement of o/c+e/f relay of 33 kv control & relay panel . ( relay make crompton ) , 2 supply of o/c+e/f relay of 11 kv feeders . ( relay make crompton ) , 2 ( a ) replacement of o/c+e/f relay of 11 kv feeders . ( relay make crompton ) , 3 supply of battery bank ( 24vdc , 180ah ) , 3 ( a ) replacement of battery bank ( 24vdc , 180ah ) , 4 supply of battery cell of battery bank installed at 33/11 kv substation ( 2vdc , 100ah ) , 4 ( a ) replacement of battery cell of battery bank installed at 33/11 kv substation ( 2vdc , 100ah ) , 5 supply of battery charger ( 24vdc , 40 a ) , 5 ( a ) replacement of battery charger ( 24vdc , 40 a ) , 6 repairing/replacement of damage/ burnt control & metering wring of 33kv , 11kv panels including fuse , indication , fuse base etc . complete as per requirement . , 7 supply of 11kv supervision relay make crompton , 7 ( a ) replacement of 11kv supervision relay make crompton , 8 supply of 11kv over/ under voltage relay of capacitor bank . , 8 ( a ) replacement of 11kv over/ under voltage relay of capacitor bank . , 9 earthing ( chemical ) of 33kv , 11kv panels ( earth resistance should be 0 . 5 ohm at ideal condition ) . , 10 supply of burnt or damage fuse base with rated mcb ( dc ) set for protection system if required . , 10 ( a ) replacement of burnt or damage fuse base with rated mcb ( dc ) set for protection system if required . , 11 repairing of dc motor of 33kv , 11kv vcb`s spring charge mechanism for auto spring charge system . , 12 supply of vacuum interrupter of 33kv , 11kv vcbs . , 12 ( a ) replacement of vacuum interrupter of 33kv , 11kv vcbs . , 13 repairing of spring charge system of vcb . , 14 repairing of 11kv , 33kv vcb lock gear . ...

Electrical Division - Uttar Pradesh

28456557 installation of kwh meter/function meter in amf panel at dg supply incoing at dg campus 1 ms conduit (isi marked) 2 pvc conduit and accessories 3 pvc/xlpe insulated aluminium/copper conductor armoured/unarmoured mv cable upto 1100 v 4 frls pvc insulated copper conductor stranded flexible wire i/c control cables 5 cable raceway floor/wall mounted and accessories 6 modular switch & socket 7 metal clad industrial socket 8 cat 6 cable 9 cable glands 10 crimp patch cord 11 protection device (mcb/rccb/db/elcb) 12 mccbs 13 power contactor 14 surge protection devices 15 panel accessories 16 selector switch 17 auxiliary relays 18 led/metal halide/fluorescent internal lighting fixture 19 external lighting fixture 20 emergency lighting/ exit sign boards 21 ceiling fan (isi marked & bee rated 5 star) 22 paint 23 advance lighting protection system (early streamer emission type) 24 gi pipe 25 main lt panels/ mcc panel 26 air circuit breaker 27 surge voltage protection 28 earth fault module 29 protection relays 30 c.ts and pts 31 digital meters 32 change over switch 33 indicating lamps 34 power capacitors 35 automatic power factor correction relay/controller 36 sealed maintenance free batteries 37 battery charger 38 cable trays (factory fabricated/overhead & floor raceways 39 hdpe underground cable duct 40 insulation mats 41 smoke/heat detectors 42 manual call point 43 response indicators 44 fire exit signs 45 fire control panel 46 speaker / hooter 47 occupancy sensors/ movement sensor 48 flush type switch /socket 49 fuse switches unit / switch fuse unit /hrc fuse 50 exhaust fan 51 xlpe insulated ht cables 52 cable lug 53 lamp holder (brass) 54 telephone wires/telephone cable / jelly filled telephone cables 55 telephone tag blocks 56 telephone outlet 57 gi raceways 58 pvc raceways 59 electronic ballast 60 dlp plastic trunking 61 geysers 62 tower light 63 ht/lt transformers 64 ht sf 6 circuit breakers/vcb 65 programmable logic controller(plc) 66 earthing (chemical earthing) plate earthing 67 octagonal pole 68 11 kv ht panel i/c relay 69 control relay panel 70 lightning arrestor 71 temp. gauge 72 gate valve 73 electrical backup 74 pvc tank 75 thermostat 76 flat collector plate 77 s.s sheet 78 ht/lt cable joints (straight through/outdoor/indoor) 79 alternator 80 dg set 81 makes of accessories of ht / lt panel / transformers 82 bus trunking 83 ht panel 11 kv 84 bus duct...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

28366982 annual maintenance of vcb/ocb annual maintenance of vcb/ocb under eudc jhansi , 1 supply of o/c+e/f relay of 33 kv control & relay panel . ( relay make crompton ) , 1 ( a ) replacement of o/c+e/f relay of 33 kv control & relay panel . ( relay make crompton ) , 2 supply of o/c+e/f relay of 11 kv feeders . ( relay make crompton ) , 2 ( a ) replacement of o/c+e/f relay of 11 kv feeders . ( relay make crompton ) , 3 supply of battery bank ( 24vdc , 180ah ) , 3 ( a ) replacement of battery bank ( 24vdc , 180ah ) , 4 supply of battery cell of battery bank installed at 33/11 kv substation ( 2vdc , 100ah ) , 4 ( a ) replacement of battery cell of battery bank installed at 33/11 kv substation ( 2vdc , 100ah ) , 5 supply of battery charger ( 24vdc , 40 a ) , 5 ( a ) replacement of battery charger ( 24vdc , 40 a ) , 6 repairing/replacement of damage/ burnt control & metering wring of 33kv , 11kv panels including fuse , indication , fuse base etc . complete as per requirement . , 7 supply of 11kv supervision relay make crompton , 7 ( a ) replacement of 11kv supervision relay make crompton , 8 supply of 11kv over/ under voltage relay of capacitor bank . , 8 ( a ) replacement of 11kv over/ under voltage relay of capacitor bank . , 9 earthing ( chemical ) of 33kv , 11kv panels ( earth resistance should be 0 . 5 ohm at ideal condition ) . , 10 supply of burnt or damage fuse base with rated mcb ( dc ) set for protection system if required . , 10 ( a ) replacement of burnt or damage fuse base with rated mcb ( dc ) set for protection system if required . , 11 repairing of dc motor of 33kv , 11kv vcb`s spring charge mechanism for auto spring charge system . , 12 supply of vacuum interrupter of 33kv , 11kv vcbs . , 12 ( a ) replacement of vacuum interrupter of 33kv , 11kv vcbs . , 13 repairing of spring charge system of vcb . , 14 repairing of 11kv , 33kv vcb lock gear . ...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

27896599 annual maintenance of vcb / ocb annual maintenance of vcb / ocb under eudc jhansi , replacement of o / c+e / f relay of 33 kv control & relay panel . ( relay make crompton ) , replacement of o / c+e / f relay of 11 kv feeders . ( relay make crompton ) , replacement of battery bank ( 24vdc , 180ah ) , replacement of battery cell of battery bank installed at 33 / 11 kv substation ( 2vdc , 100ah ) , replacement of battery charger ( 24vdc , 40 a ) , repairing / replacement of damage / burnt control & metering wring of 33kv , 11kv panels including fuse , indication , fuse base etc . complete as per requirement . , replacement of 11kv supervision relay make crompton , replacement of 11kv over / under voltage relay of capacitor bank . , earthing ( chemical ) of 33kv , 11kv panels ( earth resistance should be 0 . 5 ohm at ideal condition ) . , replacement of burnt or damage fuse base with rated mcb ( dc ) set for protection system if required . , repairing of dc motor of 33kv , 11kv vcb`s spring charge mechanism for auto spring charge system . , replacement of vacuum interrupter of 33kv , 11kv vcbs . , replacement of bearing of spring charge gear . , replacement of 11kv , 33kv vcb lock gear ....

Uttar Pradesh Power Transmission Corporation Limited - Uttar Pradesh

27893344 annual operation & maintenance of 132 / 33 kv sub station hasanganj, unnao under etd, unnao , operation , maintenance and general cleaning of 132 / 33 kv hasanganj , unnao as per standard practices of upptcl and instructions of ae ( m ) / je ( m ) for the period of 01 year , with all cost of men , misc . consumables , t&p etc . required for the job except the spares / items / material / equipments , which shall be provided by the department as per required : , round the clock , preventive , routine & general / emergency break down maintenance of transformer , switchyard equipments , control & relay panels , rtcc panels , acdb , battery sets , battery charger , dcdb ( 110v ) , acdb , dg set , lighting system ( 132 kv & 33 kv switchyard , control room , street light ) by a team comprising following experienced technical persons having 01 no . tg ii ( electrical trade ) , 01 no . fitter , 01 no . skilled helper & 01 no . no . semi skilled helper as per standard practice of upptcl & instruction of ae / je for the period of 01 year with cost of men , miscellaneous , t&p etc . required for the job except spare materials : , tg ii ( electrical ) ( skilled+iti ) . , line man / fitter ( skilled+iti ) . , helper ( semi skilled ) 02 nos . , operation of 132 / 33 kv s / s hasanganj , unnao round the clock in 04 shift of 08:00 hrs . each by deputing following persons in each shift ( ssos should be iti in electrical trade with knowledge of computer application and helper should be semi skilled ) for operation of sub station equipments , emulsifire system including dg set etc . as per standard practice of upptcl and follow up of instructions of higher officer / ae / je and clds / alds alongwith recording of operational activities system information / data message etc . , sso / tg ii ( skilled+iti ) 04 nos . , helper ( semi skilled ) 04 nos . , semi skilled helper for daily general cleaning...