All India Institute Of Medical Sciences - Uttar Pradesh
37895158 a/r and m/r to nddtc ghaziabad sh: replacement of damaged overhead water tank and gi pipe line near bore well and hydrant in nddtc ghaziabad of aiims urgent work...
37895158 a/r and m/r to nddtc ghaziabad sh: replacement of damaged overhead water tank and gi pipe line near bore well and hydrant in nddtc ghaziabad of aiims urgent work...
37822963 tender for drilling of bore well....
37816861 tender for drilling of bore well....
37720225 repair maint to chloronome plant pump sets and bore wells and repair at water supply istallation at af stn agra under ge af stn agra...
37550254 survey, soil investigation, design, construction, testing and commissioning of 50 kld feacal sludge co treatment plant at existing 16 mld jhunsi stp campus district prayagraj including all civil and em works required for successful completion of wo 1 50 kld feacal sludge co treatment plant at 16 mldjhunsi stp campus 2 construction of faecal sludge co treatment plant ( feacal sludge co treatment plant ) of 50 kld including all treatment modulesto meet following treated effluent quality parameters : ( including item no. 1.01 to 1.23 ) 3 parameter concentration not to exceed 4 bod 250 mg / l 5 cod 500 mg / l 6 tss 300 mg / l 7 ph 6 8.5 8 feacal coliform n / a 9 dewatered septage to be used as a fertilizer it should satisfy the following criteria of class a bio solids of us epa ( cept, 2015 ) . 10 faecal cloroform density < 1000 mpn / g total dry solid 11 salommenila sp density < 3mpn / 4g 12 helimith egg concentration of < 1 g total solid 13 e coli of 1000 / g total solid ( who, 2006 ) 14 the feacal sludge co treatment plant shallconsist of screening chambers, desludging units, anaerobic baffled reactor, sludge drying beds / screw press, settler and filter, planted gravel filters, sludge storageyard and other treatment units asper the technology used for treatmentin order to meet above treated effluent parameters includingstaff quarters and operator’s room, administrative buildings, watersupply works, storage tanks, electrical works, storm water drain , internal roads , dg set room , effluent channel for disposal, plumbing works etc. complete in all respect for all civil and electromechanical works 15 100% solid purethane coating of all structures / surfaces prone to corrosion and chemical action shall be provided. 16 the feacal sludge co treatment plant must also include all required sludge treatment facilities, process and control instrumentation, necessary facilities for laboratory and equipment, required buildings etc.to meet the desired standards as mentioned above.the work includes detailed design and drawings for completion of works in all respect including submission of as per built final completiondrawings . 17 construction of c.c. road includingconsruction of side wall supply of all materials, labour, tools and plants etc. complete. 18 design for the landscaping works: with flowering plants, shrubs and grass lawns 19 electrical work inside the campus 20 provision of cctv work. 21 provision for r.o. and water cooler work. 22 storm water drain 23 channel for disposal 24 soil testing 25 supply of cesspool vehicle 26 procurement of septage collection equipment including vacuum truck and appurtenances works following capacity including chasis and fabrication. 27 supply, testing and commissioning of 4000 ltr. capacity 28 supply, testing and commissioning of 3000 ltr. capacity 29 supply, testing and commissioning of 1000 ltr. capacity 30 other e&m works 31 construction of 100 mm. dia bore well of suitable depth by suitable method of drilling by rig m / c, development of borewell including all material, t & p required for proper completion ofworkand testing of water sample & also including construction of platformand drain etc 32 supply & installation ofsubmersible pump with all its accessories 33 supply and fixingof 20 watt led street light fitting confirming to ip 65 cataaa as perpwd schedule item no 1419 34 power connection 35 supply, instalation, testing and commissioning of power connection 10 kw commercial load...
37486198 tender for construction of bore well....
37267370 provision of new bore well alongwith reservoir of 1.4 lakhs gallon capacity at 7 afh kanpur cantt...
37042470 tender for comprehensive annual maintenance repair and operation contract for water treatment plant, reverse osmosis plant, plumbing bore well and sewage treatment plant....
37034066 tender for comprehensive annual maintenance repair and operation contract for water treatment plant ro plant plumbing bore wells and sewage treatment plant installed....
36995991 bids are invited for borewell dismantling and taking up submersible motor pumpset 10 hp 3 phase with connected pipes of size 80 mm dia from the tube well after dis connecting the electric connections shifting , developing flushing bore wells with compressor of capacity 400 psi borewell of 250 mm borewell and 270 feet depth complete all as directed total quantity : 2...
36877650 tender for invitation of rates for supply of civil, electrical, sanitary, other materials and piece rated works ( labour ) 1 earth work in excavation in trenches for foundation pipes, cable etc in ordinary sol ( loam clay or sand ) inlcuding lift upto 1.5 mt. lead upto 30mt. and dressing of sides and rammings of bottom and disposal of surplus excavated earth as directed by the engineer. 2 upto 1.50 m to 3.00 m deep 3 upto 3.00 m to 4.50 m deep 4 upto 4.50 m to 6.00 m deep 5 filling of carted earth 6 laying in position cement concrete of specifiedgrade including the cost of centring and shuttering all work upto plinth level. 7 in cement concrete 1:4:8 ( 1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size ) 8 in cement concrete 1:2:4 ( 1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size ) 9 coarse sand ( compacted ) filling in sides of foundation & floor 10 providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. ( plinth area of the building at ground floor only shall be measured as per i.s.6313 ( partii 1981 ) alderine emulsifiable concentrate or any other approved material such as heptrachlor or chlordane will be used. the rate of application of chemical emulsion shall be as follows : ( 1 ) treatment for masonary & foundation 5 liters per sqm. ( 2 ) back fill in immediate contact with foundation 7.5 liters / sqm ( 3 ) treatment of top surface of plinth filling 5 liters / sqm ( 4 ) treatment junction of wall and the floor 7.5 liters / sqm ( 5 ) treatment of soil along external perimeter of building 7.5 liters / sqm ( 6 ) treatment of soil under apron along external perimter 5 liters / sqm. ( as per manufacturers standard dilution ) 11 r.c.c. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 bwg binding wire and including necessary centering and shuttering etc.and also excluding supply of all materials, and including labour and tools and plants etc, required for proper completion of the works. 12 ground floor 13 first floor 14 second floor 15 as in item no. 6 above but for slabs ( using 1:1.5:3 mix concrete ) . 16 ground floor 17 first floor 18 second floor 19 as in item 6 but for thelighterbeams i.e. having spans upto 6 m. ( using 1:1.5:3 mix concrete ) 20 ground floor 21 first floor 22 second floor 23 as in item 6 abovebut inr.c.c.raft foundation and footingwithapproved stone ballast. ( using1:1.5:3mix concrete ) 24 as in item 6 above but in r.c.c. columns in 1:1.5:3 having strength not less than m 20. 25 ground floor 26 first floor 27 second floor 28 m 150 brick work in 1:6 ( one cement and six coarse sand sand of 2.25 fineness modulus ) mortar infoundation & plinth includinglabour and t & p etc & excluding supply of all materials, required for proper completion of the work. 29 m 150 brick work in 1:4 ( one cement and six coarse sand sand of 2.25 fineness modulus ) mortar infoundation & plinth includinglabour and t & p etc & excluding supply of all materials, required for proper completion of the work. 30 laying damp proof course 40mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 12.5mm nominal size ) 31 applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 32 same as in item no. 11 abovebutin super structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. ( 1:6 cement : coarse sand ) 33 ground floor 34 first floor 35 second floor 36 same as in item no. 14 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 37 ground floor 38 first floor 39 second floor 40 mild steel or iron in plain work such as reinforced concrete or reinforced, brick work ( when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and excluding supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 41 ground floor 42 first floor 43 second floor 44 15 mm cement plaster on rough side of single or half brick wall of mix : 1:3 ( 1 cement: 3 coarse sand ) 45 15 mm cement plaster in single coat on rough side of single or halfbrick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. ( 1 ) 1 cement : 6 fine sand . 46 ground floor 47 first floor 48 second floor 49 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and / or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. ( 1 ) 1 cement : 6 finesand. 50 ground floor 51 first floor 52 second floor 53 engraving lines in the plaster of outer face well vertically & horizontally to display the surface as stone facing as directed by the engineer in charge including labpur, & t & p etc. required for proper completion of the work. 54 ground floor 55 first floor 56 second floor 57 add for plaster drip course / groove in plastered surface or moulding to r.c.c. projections. 58 laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) finishing with cement slurry & with pigment grouting & polishing complete including supply of all labour, t & p etc. excluding the cost of materials required for proper completion the work. 59 ground floor 60 first floor 61 second floor 62 laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand ) finishing with cement slurry & with pigment grouting & polishing complete including supply of all labour, t & p etc. excluding the cost of materials required for proper completion the work. 63 ground floor 64 first floor 65 second floor 66 kota stone slab flooring over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : 25 mm thick 67 ground floor 68 first floor 69 second floor 70 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 71 ground floor 72 first floor 73 second floor 74 fixing of 6 mm thick approved china white / coloured glazed tiles in flooring or dado laid with 1:3 cement and approved coarse sand mortar finished and jointed with white cement slurry and pigment and polishing complete includinglabour and tool sand plants & excluding supply of all materials, etc. required for proper completion of the work. 75 ground floor 76 first floor 77 second floor 78 25 mm thick cement concrete flooring 1:2:4 ( 1 cement :2 coarse sand :4 graded stone aggregate 12.5mm nominal size and below ) by laid over base concrete finished with floating coat of neat cement ( base concrete to be paid separately ) including fixing of glass strips. ( excluding cost of glass strips ) 79 supply of flush doors commercial qualityconforming to i.s.2202 part i ( 1983 ) including fixing of wooden cleats and stoppers 80 35 mm thick 81 ( a ) single leaf 82 ( b ) double leaf 83 32 mm thick 84 ( a ) single leaf 85 extra for providing and fixing flush doors with decorative veneering instead of non decorative isi marked flush door shutters conforming to is: 2202 ( part i ) 86 fixing of flush / pvc doors including fixing of wooden / pvc cleats and stoppers and includingfixing and adjustment of hinges, bolts, locks, handle, springs. fittings to be supplied departmentally. 87 supply of factory made panel pvc door shutter consisting of frame made out of m.s. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. m.s. frame shall have a coat of steel primers of approved make and manufacture. m.s. frame covered with 5 mm thick heat moulded pvc ‘c’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide pvc sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide pvc sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. top, bottom and lock rails shall be provided both side of the panel. 10 mm ( 5 mm x 2 ) thick, 20 mm wide cross pvc sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side pvc sheet to be fitted in the m.s. frame welded / sealed to the styles & rails with 7 mm ( 5 mm+2 mm ) thick x 15 mm wide pvc sheet beading on inner side, and joined together with solvent cement adhesive. an additional 5 mm thick pvc strip of 20 mm width is to be stuck on the interior side of the ‘c’ channel using pvc solvent adhesive etc. complete as per direction of engineer in charge, manufacturer’s specification & drawing. 30 mm thick plain pvc door shutters 88 mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods, gratings etc. ( when not included in an over all rates ) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 89 m.s. hold fast for doors and windows 90 m.s. grill 91 z section winodws ( openable ) 92 m.s. angle door chaukhat 40*40*5 93 fixing of door, windows / ventilators chaukhats in position. 94 ( a ) door chaukhats 95 ( b ) window chaukhats 96 ( c ) ventilator chaukhats 97 distempering ( two coat ) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as berger, j&n, shalimar, asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. ( inside walls ) 98 ground floor 99 first floor 100 second floor 101 finishing walls with two coat of acrylic smooth exterior paint of best quality including supply of all materials labour and tool sand plants etc. required for proper completion of the work. 102 ground floor 103 first floor 104 second floor 105 finishing wall with water proof cement paint of approved make and quality on new wood with two coat to give an even shade including supply of all materials, labour, tools and plant etc. required for proper completion of the work. ( two coat ) 106 wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : two or more coats on new work supply of all materials, labour, tools and plant etc. required for proper completion of the work. ( two coat ) 107 distempering ( two coat ) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as berger, j&n, shalimar, asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth excludingcost of all materials. ( ceiling ) 108 providing & applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 109 supply of 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. 110 supply of stainless steel sliding door bolts isi marked anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade with nuts and screws etc complete. ( a ) 250mm x 16mm . 111 supply of stainless steel towerbolts ( barrel type ) with necessary screws etc. complete 112 ( a ) 300mm x 10mm 113 ( b ) 250 mm x 10mm 114 supply of bright / matt finished stainless steel handles of approved quality & make with necessary screws etc all complete. ( a ) 125 mm 115 providing and laying cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a ) applying a slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b ) laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand ) admixed with water proofing compound conforming tois : 2645 and approved by engineer in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c ) after two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge. d ) finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e ) the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. all above operations to be done in order and as directed and specified by the engineer in charge : with average thickness of 120 mm and minimum thickness at khurra as 65 mm. 116 painting or vanishing two coat on iron work in small areas or new wood work with one coat of ready mixed priming paint and one coat of approved superior ready mixed paint of clear synthetic varnish including supply of all materials, labour, t & p etc. required for proper completion the work. paint to be used should confirm to the i.s.i. no. 103 1950. 117 same as item above but on new wood surface. 118 fixing panes of glass with equal or equivalent i.s.i. marked quality putty, brads and springs including supply of all materials, labour etc. complete. 3.80 to 4.70 mm thick 119 chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing & excluding supply of all materials complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement :4 coarse sand ) : light shade pigment using white cement. 120 filling of light cinder filling under floor of toilets & other sunken roofs. 121 labour charges for wiring points for light with 1.5 sqmm.frlsh pvc insulated single core copper condutor cable in pvc conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.frlsh pvc insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. 122 same as item no. ( 1 ) but for two way light points. 123 same as item no. ( 1 ) but for fanandlight duty exhaust fan. 124 same as item no. ( 1 ) but for5amp plug point with piano type switch and socket etc. 125 addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. 126 addition for light / fan points with modular type switchin place of piono type switch. 127 addition for plugpointswith modular type switchin place of piono type switch. 128 addition for exhaust fanpointswith modular type switchin place of piono type switch. 129 wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm fr pvc insulated 1100 v grade single core multistrand copper conductor cable in 20 mm dia heavy duty ( 2mm thick ) pvc conduit complete, including supply of all material, labourand t&p etc. required for proper completion of the work as directed by engineer i / c. 130 wiring of submain 2 number 4 sqmm . frlsh pvc insulated 1100 v grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 20mm dia pvc conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm frlsh pvc insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 131 wiring of submain 2 number 6 sqmm . frlsh pvc insulated 1100 v grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 20mm dia pvc conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm frlsh pvc insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 132 wiring of submain 4 number 10 sqmm . frlsh pvc insulated 1100 v grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 32mm dia pvc conduitalong with two numbers 6 sqmm frlsh pvc insulated multistranded copper conductorcable as earth contunity wire etc. complete in all respects. 133 wiring of submain 4 number 16 sqmm . frlsh pvc insulated 1100 v grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 40mm dia pvc conduitalong with two numbers 10 sqmm frlsh pvc insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 134 wiring of submain 4 number 25 sqmm . frlsh pvc insulated 1100 v grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 50mm dia pvc conduitalong with two numbers 16 sqmm frlsh pvc insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. 135 fixing and concealing of20mm dia.2mm thick pvc conduit pipe with isi mark embossed and with pvc acessories confirming to is no. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to level with matching colour including cost of material labour and t & p etc required for proper completion of work ( fortelephone ) 136 erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick g.i. pipe 19mm dia duly painted, complete in all respects. 137 erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. 138 fixing of hexagonal / round g.p. fan box of approved make made up of 1.0mm thick isi marked g.p. sheet spot weeldeed four to eight holes of 25.4 mm for pipe entry of the box. holes should be semi shuttered type with 0.5mm g.p. sheet made upper & lower cover duly screewed fitted with 300mm round zink coted m.s bar x 12mm & brand name should be embossed.fixing with wiring conduit laid in the r.c.c roof before concreting alongwith supply of all material, labour, t&p etc. required for proper completion of the work. 139 supply of ceiling fan with fan motor of a.c permanent insulation, capacitor rating conforming bee 5 star rating and is:374 / 79 and also comply with is: 1709 / 1984 with latest amendment. the rated voltage 220 / 240 volts, 50hz, 1 ph ac the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system. bee 5 star rated 1200mm sweep 140 fixingofelectronic fan regulator ( modular ) 120 280 v. isimarked, on the existing switch board including making connetion, required material, labour t / p etc for proper completion of work to the satisfaction of engineer in charge of work. 141 fixing of led tube light with metal heavy dutybox type batten light fitting 2 x 22 watt suitable for up to 2 x 22 watt led polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects. ( cat: aaa ) 142 fixing of led tube light with metal heavy dutybox type batten light fitting 1 x 22 watt suitable for up to 1 x 22 watt led polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects. ( cat: aaa ) 143 fixing of recess / surface mounting round 10 to 15 watt, cut out min 125mm, height min 40mm, led down lighter having powder coated die cast aluminium housing with heat sink, diffuser / reflector and driver set, suitable for 24hr continuous operation, complete in all respect. ( cat: aaa ) 144 fixing of single led light wall bracket on matching m.d.f.e.g board base etc. complete in all respect. ( cat: aaa ) 145 fixing of water tight oblong 10 watt led bulhead luminaire with driverr set confirming to ip 65 and above protection complete in all respect. ( cat: aaa ) 146 fixing of surface / flush mounting distribution boards with additional metal door withot mcb complete in all respects. ( cat a ) 147 4 way tpn 148 6 way tpn 149 8 way tpn 150 fixing of 6amp to 32 amp ( 10 ka ) sp mcb in existing mcb, db complete with connections as required. ( cat: a ) 151 fixing and making connection of following mcbs complete in all respects as per direction and satisfaction of engineer in charge. ( cat: a ) 152 40 amp. fp mcb ( cat: a ) 153 63 amp. fp mcb ( cat: a ) 154 fixing of surface / flush mounting v tpn distribution boards with additional metal door withot mcb complete in all respects. ( cat a ) 4 way v tpn 155 fixing and making connection of following mccbs complete in all respects as per direction and satisfaction of engineer in charge. ( cat: a ) 156 100 amp. fp mccb ( cat: a ) 157 125 amp. fp mccb ( cat: a ) 158 160 amp. fp mccb ( cat: a ) 159 fixing and making connection of following mcbs complete in all respects as per direction and satisfaction of engineer in charge. ( cat: a ) 160 40 amp. tp mcb ( cat: a ) 161 63 amp. tp mcb ( cat: a ) 162 fixing of power plug with 15a / 250 v flush type switch and 5 pin 15 a / 250v flush type universal socket in suitable m.s. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. 163 fixing of power plug with 20a / 250 v flush type switch and 5 pin 20 a / 250v flush type universal socket in suitable m.s. box including supply of all material, labor t&p etc. required for proper completion of work. 164 fixing of single pole mcbs blanking plate complete in all respects. ( cat: a ) 165 fixing and making connection of following mccbs complete in all respects as per direction and satisfaction of engineer in charge. 63 amp. fp mccb 166 supply and burying of 600mm x 600 mmx6mm g.i. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm g.i.pipe and funnel for watering and two earthing leads of no.8to10swg g.i.wire in 15mm dia g.i. pipe upto switch board ( from apron to switch board the cost of g.i. pipe and g.i. wire will be extra ) 30cm. square c.i. frame with hinged cover, masonary housing, alternate layers / of charcoal / coke and salt at least 150mm thick alround etc. complete in 167 laying of 25mmx3mm g.i. strip for earthing purpose as required complete in all respects. 168 fixing of two number 8 swg g.i. wire in 15mm dia gi pipe for earthing purpose as required complete in all respects. 169 laying of aluminium conducter, pvc insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the 170 95 sqmm3.5 core 171 70 sqmm3.5 core 172 50 sqmm3.5 core 173 35 sqmm3.5 core 174 25 sqmm3.5 core 175 10 sqmm4 core 176 fixing of brass nickle plated compression gland for pvc insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. the armouring of the cable shall be properly connected with the earth as per dire 177 95 sqmm3.5 core 178 70 sqmm3.5 core 179 50 sqmm3.5 core 180 35 sqmm3.5 core 181 25 sqmm3.5 core 182 10 sqmm4 core 183 fixing of palm / pin type copper tin plated cables sockets ( lugs ) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of engineer incharge. 184 95 sqmm 185 70 sqmm 186 50 sqmm 187 35 sqmm 188 25 sqmm 189 16 sqmm 190 10 sqmm 191 6 sqmm 192 fixing ofmodular boxes, base & cover plate 193 fixing of following size / modules, gi box along with modular base& cover plate for modular switches in recess etc as required. 1 or 2 module ( 75mm x 75 mm ) 194 fixing ofmodular type switch / socket : 195 fixing of following modular switch / socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. 196 telephone socket outlet 197 tv antenna socket outlet 198 bell push 199 fixing of call bell / buzzer suitable single phase, 230 v etc as required. 200 laying oftelephone wire following pair 0.5 sqmm fr pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel / pvc conduit as required. 2 pair 201 drawing of co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. 202 drawing telephone wire following pair 0.5 sqmm fr pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel / pvc conduit as required. 203 20 pair 204 10 pair 205 fixing of 10 pair junction boxes for floors and building with krone connectors , with connection and punching of same 206 fixing of 20 pair junction boxes for floors and building with krone connectors , with connection and punching of same 207 fixing of 50 pair junction boxes for floors and building with krone connectors , with connection and punching of same 208 laying unplastisized rigid pvc pipe conforming to is:13592 type a including jointing , cuttingand making good the walls & floors as per requirement. 150mm 209 supply of ac 230 / 250 volts, 50 hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep. 210 fixing of energy meter and other accessories including connections etc. complete as required 3 phase meter 211 erection of ac 230 / 250 volts, 50 hz wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required450mm sweep. 212 supply of ac 230 / 250 volts, 50 hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required450mm sweep. ( at labs ) 213 fixing of wired decorative mirror light on suiatable for 9 watt led with lamp complete in all respect. 214 fixing of factory wired integral led flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 watt conforming to ip 65 / 66 protection complete in all respect. ( cat aaa ) 215 providing and laying water proofing treatment in sunken portion of wcs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a ) first layer of slurry of cement @ 0.488 kg / sqm mixed with water proofing cement compound @ 0.253 kg / sqm. this layer will be allowed to air cure for 4 hours. b ) second layer of slurry of cement@ 0.242 kg / sqm mixed with water proofing cement compound @ 0.126 kg / sqm.this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. the rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 216 fixing of stainless steel ( grade 304 ) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature ( wherever required ) and fitting the same with necessary stainless steel nuts and bolts complete, i / c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, excluding the cost of materials on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge. 217 providing and fixing of expansion joint system related with floor location as per drawings and direction of engineer in charge. the joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per astm b221 02. the system shall be such that it provides floor to floor / floor to wall expansion control system for various vertical localtion in load application areas thatccommodates multi directional seismic movement without stress to its components. system shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. the cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre engineered self centering arrangement that freely rotates / moves in all directions.the self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. provision of moisture barrier membrane in the joint system to have watertight joint is mandatory requirement all as per the manufactures design and as approved by engineer in charge. ( material shall confirm to astm 6063 ) floor joint of 100 mm gap 218 providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of engineer in charge. the joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper astm b221 02. the system shall be such that it provides watertight roof to roof / roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. system shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. the cover plate shall be designed of width and thickness required to satisfy movement 219 and loading requirements and secured to base members by utilizing manufacturer’s pre engineered self centering arrangement that freely rotates / moves in all directions. the self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including verticalisplacement. the joint system shall resists damage or deterioration from the impact of falling ice, exposure to uv, airborne contaminants and occasional foot traffic from maintenance personnel. provision of moisture barrier membrane in the joint system to have water tight joint is mandatory requirement. ( material shall confirm to astm 6063. ) roof joint of 100 mm gap 220 providing and fixing of expansion joint systemelated with wall joint ( internal / external ) location as per drawings and direction of engineer in charge. the joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per astm b221 02. the material shall be such that it provides an expansion joints system suitable for vertical wall to wall / wall to corner application, both new and existing construction in office buildings & complexes with no slipping down tendency amongst the components of the joint system. the joint system shall utilize light weight aluminum profiles exhibiting minimalexposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. ( material shall confirm to astm 6063 ) .wall joint of 100 mm gap 221 fixing in position stainless steel grade 304 plate 1.0 mm thick as per design for expansion joints. 200 mm wide. 222 granite stone slab 18 mm thick mirror polished quarter rounded with anti skid lines in treads of staircase full length flooring over 20 mm ( average ) thick base laid over and jointed with cement slurry mixed with pigment to match the shade of including rubbing & polishing complete with base of cement mottar 1:4 ( 1 cement : 4 coarse snad ) etc. complete excluding the cost of materials. 223 ground floor 224 first floor 225 second floor 226 fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of t iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, ocking arrangement, stoppers, handles, including applying a priming coat of approved steel primer & excluding the cost of materials. 227 fixing rolling shutters of approved make of 80 × 125 mm ( 3 × 18 gauge ) cold rolled ml lath inter lockedthrough their eintire length and joined together at the end by locks and mountedon specially designed pipe shaft with brackets and wall bearing & excluding the cost of materials. 228 40mm thick cement concrete flooring 1:2:4 ( 1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size and below ) by laid over base concrete finished with floating coat of neat cement ( base concrete to be paid separately ) including fixing of glass strips. ( excluding cost of glass strips ) 229 fixing glass strips in joints of floors and skirting or dado add the item of laying floors flush with floor level including supply of all materials, labour, t & p etc. required for proper completion the work. ( a ) 37 mm wide and 3.15 mm thick 230 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) and top layer 12 mm thick cement hardener consisting of mix 1:2 ( 1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size ) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturers specifications.but excluding the cost of materials etc. complete. 231 supply of 80mm thick rubber moulded cement concrete interlocking pavers block. the compressive strength of concrete pavers blocks shall not be less than 30mpa & 4.5kg / no. 232 providing and laying of 80mm thick rubber moulded cement concrete interlocking pavers block. the compressive strength of concrete pavers blocks shall not be less than 30mpa & 4.5kg / no. 233 fixing of angle iron frame 40x40x6 mm in position. 234 fencing with r.c.c. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres ( minimum ) , between the two posts fitted and fixed with g.i. staples on wooden plugs or g.i. binding wire tied to 6 mm bar nibs fixed while casting the post ( cost of r.c.c. posts, struts, g.i. barbed wire, earth work and concrete to be paid for separately ) 235 mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 236 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. with 2nd class teak wood beading 62x19 mm. 237 providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 35 mm thick shutters with isi marked m.s. pressed butt hinges bright finished of required size 238 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. extra for providing and fixing flush doors with decorative veneering instead of non decorative isi marked flush door shutters conforming to is: 2202 ( part i ) on one side only 239 p / f curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with c.p. brass screws and wooden plugs etc. wherever necessary complete ( a ) 25 mm dia. 240 fixing of g.i. pipe ( 80 mm dia ) as per design & drawing as per drection of eic 241 fabrication of angle iron door chaukhat of 40*40*6 mm 242 supply of concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m ) , having 50 nos rounds per 6 metrelength, upto 3 m height of wall with existing angle iron ‘y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal r.b.t. reinforced barbed wire, stud tied with g.i. staples and g.i. clips to retain horizontal, including necessary bolts or g.i. barbed wire tied to angle iron, all complete as per direction of engineer in charge, with reinforced barbed tape ( r.b.t. ) / spring core ( 2.5mm thick ) wire of high tensile strength of 165 kg / sq.mm with tape ( 0.52 mm thick ) and weight 43.478 gm / metre. 243 fixing of concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m ) , having 50 nos rounds per 6 metrelength, upto 3 m height of wall with existing angle iron ‘y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal r.b.t. reinforced barbed wire, stud tied with g.i. staples and g.i. clips to retain horizontal, including necessary bolts or g.i. barbed wire tied to angle iron, all complete as per direction of engineer in charge, with reinforced barbed tape ( r.b.t. ) / spring core ( 2.5mm thick ) wire of high tensile strength of 165 kg / sq.mm with tape ( 0.52 mm thick ) and weight 43.478 gm / metre ( cost of materialsshall be paid separately ) 244 supply of m.s. foot rest as per standard design with 20x20mm sq bars. 245 fixing of m.s. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 246 supply ofc.i. tee at the inlet and outlet of septic tank. 247 fixing c.i. tee at the inlet and outlet of septic tank. 248 supply of 75mm dia vent pipes. 249 fixing of 75mm dia vent pipes. 250 supply of 75mm dia cast iron terminal guard. 251 fixing of 75mm dia cast iron terminal guard. 252 supply ofprecast rcc manhole cover and frame of required shape and approved quality. 253 m.d. 10 circular shape 500mm internal diameter 254 m.d. 2.5 circular shape 450mm internal diameter 255 fixing in position precast rcc manhole cover and frame of required shape and approved quality. 256 m.d. 10 circular shape 500mm internal diameter 257 m.d. 2.5 circular shape 450mm internal diameter 258 excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 259 up to 1.50 m depth 260 pipes 80 mm to 300 mmdiameter 261 1.50 m to 3.00 m depth 262 pipes 80 mm to 300 mmdiameter 263 opentimbering in trenches including shuttering and shoring complete. ( measurement to be taken of the face area timbered ) 264 depth not exceeding 1.5 meter 265 depth 1.5 to3.00meter 266 supply of non pressurenp 2 class ( light duty ) rcc pipe with collars etc. complete. 267 150 mm.dia. rccpipes 268 250 mm.dia. rccpipes 269 100 mm dia rcc pipes 270 laying of nonpressurenp 2 class ( light duty ) rcc pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 ( 1cement : 2 finesand ) includingtestingof joints etc. complete. 271 150 mm.dia. rccpipes 272 250 mm.dia. rccpipes 273 100 mm dia rcc pipes 274 laying cement concrete 1:5:10 ( 1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size ) upto the haunches of pipes including bed concrete as per standard design 275 150 mm.dia. rccpipes 276 250 mm.dia. rccpipes 277 100 mm dia rcc pipes 278 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement :4 coarse sand ) rcc top slab with 1:2:4 mix ( 1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size ) , foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size ) inside plastering 12mm thick with cement mortar 1:3 ( 1 cement :3 coarse sand ) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 ( 1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size ) finished with a floating coat of neat cement complete as per standard design. 279 inside size 90x80cms and 45cms deep including ci cover with frame ( light duty ) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15kg ) . 280 extra for depth for manholes: 281 inside size 90x120cms and 90cms deep including ci cover with frame ( medium duty ) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58kg ) . 282 extra for depth for manholes: 283 supply of orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per is:10910 on 12 mm dia steel bar conforming to is:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing. 284 fixing of orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per is:10910 on 12 mm dia steel bar conforming to is:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per design. 285 supply of double flanged ( screwed / welded ) centrifugally ( spun ) ductile iron pipes of class k 9 conforming to is 8329 100mm dia ductile iron double flanged 286 fixing & laying double flanged ( screwed / welded ) centrifugally ( spun ) ductile iron pipes of class k 9 conforming to is 8329 100mm dia ductile iron double flanged 287 supply of ci specials such as bends, reducers, collars etc. including cartage, loading, unloading, taxes, excise etc. complete. 288 fixing of ci specials such as bends, reducers, collars etc. including cartage, loading, unloading, taxes, excise etc. complete. 289 supply of push on joints to centrifugally ( spun ) cast iron pipes or ductile iron pipes including testing of joints and including the cost of rubber gasket : 100mm dia pipes 290 fixing of push on joints to centrifugally ( spun ) cast iron pipes or ductile iron pipes including testing of joints and including the cost of rubber gasket : 100mm dia pipes 291 supply ofc.i. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) : 100mm diameter 292 fixing of c.i. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) : 100mm diameter 293 supply of c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc. if required will be paid separately. a ) 50mm dia 294 fixing of c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc. if required will be paidsaperately 50mm dia 295 supply of g.i. pipes ( medium ) complete with g.i. fittings 296 80mm nominal bore. 297 65mm nominal bore. 298 50mm nominal bore. 299 40mm nominal bore. 300 32mm nominal bore. 301 25mm nominal bore. 302 20mm nominal bore. 303 15mm nominal bore. 304 laying, jointing, testing & commisioning ofg.i. pipes complete with g.i. fittings includingtenching and refilling etc. ( external work ) 305 80mm nominal bore. 306 65mm nominal bore. 307 50mm nominal bore. 308 40mm nominal bore. 309 32mm nominal bore. 310 25mm nominal bore. 311 20mm nominal bore. 312 15mm nominal bore. 313 supplying of specials for pressure pipe. 314 fixing of specials for pressure pipe. 315 supply ofgate valve ( with cap complete with bolts, nuts, rubber insertion etc. 316 80mm nominal bore. 317 65mm nominal bore. 318 50mm nominal bore. 319 40mm nominal bore. 320 32mm nominal bore. 321 25mm nominal bore. 322 fixing of gate valve ( with cap complete with bolts, nuts, rubber insertion etc. 323 80mm nominal bore. 324 65mm nominal bore. 325 50mm nominal bore. 326 40mm nominal bore. 327 32mm nominal bore. 328 25mm nominal bore. 329 constructing masonry chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand ) for sluice valve, with c.i. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep ( inside ) with chained lid and rcc top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i / c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 330 constructing brick masonry chamber 600 x 600x750mm insidewithf.p.s. brickwork in cement mortar 1:4 ( 1 cement : 4 coarse sand ) for sluice valve / air valve, with c. i. surface box 100 mmtop diameter, 160 mm bottom diameter and 180mm deep ( inside ) with chained lid and rcc top slabwith 1 : 2 : 4 mix ( 1 cement : 2 coarsesand : 4 gradestone aggregate 20 mm nominal size ) ; necessary excavation, foundationconcrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plasteringwithcement mortar 1 : 3 ( 1 cement : 3 coarsesand ) 12mmthick finished with a floatingcoatofneat cementcomplete as per standarddesign 331 supply offire brigade inlet with 63 mm dia instantaneous inlet complete with all necessary fittings and ms enclosure with glass door made of 18 / 16 swg sheet. 4 way 332 fixing, installation, testing & commissioning offire brigade inlet with 63 mm dia instantaneous inlet complete with all necessary fittings and ms enclosure with glass door made of 18 / 16 swg sheet. 4 way 333 supply of sluice valve complete with flanges, gasket, nut bolts 150 mm 334 fixing, installation, testing & commissioning of sluice valve complete with flanges, gasket, nut bolts 150 mm 335 supply of nrv complete with flanges, gasket and nut bolts. 150 mm 336 fixing, installation, testing & commissioning of nrv complete with flanges, gasket and nut bolts. 150 mm 337 supply of ms pipes conforming to is:1239 ( medium b class ) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required ( for riser ) 338 150 mm dia 339 100mm dia 340 fixing of ms pipes conforming to is:1239 ( medium b class ) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required, cutting holes and chases in brick or rcc walls and making good complete. ( for riser ) 341 150 mm dia 342 100mm dia 343 supply of manual swing type first aid fire hose reel conforming to is: 444 complete with all other necessary fixing accessories. 344 fixing, installation, testing and commissioning of manual swing type first aid fire hose reel conforming to is: 444 complete with all other necessary fixing accessories. 345 supply of fire man axe. 346 fixing of fire man axe. 347 supply of singal headed hydrant landing valve comprising of 80 mm dia flanged bend 63 mm dia, with cap and chain conforming to is:5290 ( make : newage / minimax / safex / firex ) 348 fixing, installation, testing & commissioning of singal headed hydrant landing valve comprising of 80 mm dia flanged bend 63 mm dia, with cap and chain conforming to is:5290 ( make : newage / minimax / safex / firex ) 349 supply of rrl hose pipe 63 mm dia × 15 mtr. long with gm coupling conforming to is : 636 ( make newage / jayshree / crc ) 350 fixing, installation, testing & commissioning of rrl hose pipe 63 mm dia × 15 mtr. long with gm coupling conforming to is : 636 ( make newage / jayshree / crc ) 351 supply of short branch pipe as per is:903 ( make : newage / safex / firex ) 352 fixing, installation, testing & commissioning of short branch pipe as per is:903 ( make : newage / safex / firex ) 353 supply of butterfly valve complete with flanges, gasket, nut bolts 100 mm 354 fixing, installation, testing & commissioning of butterfly valve complete with flanges, gasket, nut bolts 100 mm 355 supply of hose cabinet box of 18 swg m.s.sheet with glass to accommodate hose reel drum with ruber pipe with nozzle. 2 nos. rrl hose and 1 no. branch pipe with nozzle 356 fixing, installation, testing & commissioning of hose cabinet box of 18 swg m.s.sheet with glass to accommodate hose reel drum with ruber pipe with nozzle. 2 nos. rrl hose and 1 no. branch pipe with nozzle 357 supply of air cushion tank ( 2000x1000 ) mm. 358 fixing, installation, testing & commissioning of air cushion tank ( 2000x1000 ) mm. 359 supply of air release valve. 360 fixing, installation, testing & commissioning of air release valve. 361 supply of nrv complete with flanges, gasket and nut bolts. 100 mm 362 fixing, installation, testing & commissioning of nrv complete with flanges, gasket and nut bolts. 363 supply of pressure gauge with gauge cock 364 fixing, installation, testing & commissioning of pressure gauge with gauge cock 365 supply of electrical motor driven fire pump suitable for automatic operation consisting of following : ( terrace pump ) ( make : kirloskar / mather+platt ) ( a ) horozontally mounted, split casing, centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class gi pipe and control valves for proper completion of work.the pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.the pump shall be provided with mechanical seals. the impeller shall be enclosed type and accurately blanced dynamically.the pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. ( b ) squirrel cage, tefc induction motor suitable for 415 v, 3 phase having ip 55 protection and class b insulation for the above pump and flexible coupling with the pump.the motor shall b rated for continuous duty and shall have hp rating necessary to drive th pump at 150% of its rated discharge at 65% of rated head. © common bed plate of fabricated mild steel channel or cast iron type. ( d ) suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc. ( e ) pressure switch for automatic operation of motor including necessary wiring upto control panel. ( f ) electrical control panel with starter, 3 pole motor protection category current limiting type mccb, indicating light, ammeter, voltmeter, selector switches, cts protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details.discharge :450 liter per minute head : 35 meter 366 installation, testing and commisioning of electrical motor driven fire pump suitable for automatic operation consisting of following : ( terrace pump ) ( make : kirloskar / mather+platt ) ( a ) horozontally mounted, split casing, centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class gi pipe and control valves for proper completion of work.the pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.the pump shall be provided with mechanical seals. the impeller shall be enclosed type and accurately blanced dynamically.the pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. ( b ) squirrel cage, tefc induction motor suitable for 415 v, 3 phase having ip 55 protection and class b insulation for the above pump and flexible coupling with the pump.the motor shall b rated for continuous duty and shall have hp rating necessary to drive th pump at 150% of its rated discharge at 65% of rated head. © common bed plate of fabricated mild steel channel or cast iron type. ( d ) suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc. ( e ) pressure switch for automatic operation of motor including necessary wiring upto control panel. ( f ) electrical control panel with starter, 3 pole motor protection category current limiting type mccb, indicating light, ammeter, voltmeter, selector switches, cts protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details.discharge :450 liter per minute head : 35 meter 367 ( a ) horozontally mounted, split casing, centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class gi pipe and control valves for proper completion of work.the pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.the pump shall be provided with mechanical seals. the impeller shall be enclosed type and accurately blanced dynamically.the pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. 368 fixing & placing on terrace ( at all floor levels ) polyethylene water storage tank isi : 12701 marked indicating the bis license no. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank. [ sintex, electroplast, star, lotus or equivalent having valid isi license ] . 369 supply of halon free portable fire extinguishers as described below: 370 4.5 kg carbon dioxide extinguisher, is marked, with high pressure discharge tube, horn, control valve, cce approved cylinder 371 6 kg mono ammonium phosphate ( abc ) type cartridge operated extinguishers 372 9 kg mono ammonium phosphate ( abc ) type cartridge operated extinguishers 373 providing, fixing, testing and commissioning of 50 litres ( trolley mounted ) mechanical foam type fire extinguisher. in hp mild steel cylinders isi marked tac approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to is:910 . 374 providing, fixing, testing and commissioning of co2 type fire extinguisher of capacity 22.5 kg filled with co2 gas as per is 15222 with controll discharge mechanism fitted with hose, horn & trolleyconfirms to is 2878 bearing isi mark. co2 cylinder as per is 7285 375 fixing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire extinguishers as described below: 376 supply of fire related signages printed on photoluminescent u1000 aluminium sheet of 1.0 mm ( + 10% ) containing lumigen ii as base chemical, covered under uv stablized coating and of appropriate size for fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete. 377 fixing of fire related signages printed on photoluminescent u1000 aluminium sheet of 1.0 mm ( + 10% ) containing lumigen ii as base chemical, covered under uv stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by engineer in charge. 378 supply ofci cover with frame light weight complete as perdesign size 600x600 mm 379 supply ofci cover with frame light weight complete as perdesign size 900x900 mm 380 boring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in is: 2800 ( part i ) , including collecting samples from different strata, preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, beyond 90 metre & upto 150 metre depth below ground level.drilling of 250 mm dia bore hole manually. 381 supply of unplasticized pvc medium well screen ( rms ) pipes with ribs, conforming to is: 12818, fittings & accessories etc. all complete, for all depths, as per direction of engineer in charge.150 mm nominal size dia 382 assembling, lowering and fixing in vertical position in bore well unplasticized pvc medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of engineer in charge.150 mm nominal size dia 383 supply of stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. 384 supply of gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. 385 supply of coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of engineer incharge. 386 filling, spreading & leveling coarse sand, gravels & stone boulders of size range 1.5 mm to 20 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of engineer incharge. 387 transportation charges of drilling equipment including assembly and other material as required. 388 drilling of 675 mm. dia by rotary machine 389 supply of 350 mm. dia housing pipe ( 8 mm. thick ) 390 laying of 350 mm. dia housing pipe ( 8 mm. thick ) 391 supply of 200 mm. dia blind pipe ( 8 mm. thick ) 392 laying of 200 mm. dia blind pipe ( 8 mm. thick ) 393 supply of 200 mm. dia slotted pipe ( 8 mm. thick ) 394 laying of 200 mm. dia slotted pipe ( 8 mm. thick ) 395 supply of 350 mm. dia socket 396 fixing of 350 mm. dia socket 397 supply of 200 mm. dia socket 398 fixing of 200 mm. dia socket 399 supply of 200 mm. dia bail plug 400 fixing of 200 mm. dia bail plug 401 supply of 350 mm. dia well cap 402 fixing of 350 mm. dia well cap 403 supply of 350x200 mm. dia reducer. 404 fixing of 350x200 mm. dia reducer. 405 supply of 350 mm. dia housing clamp 406 fixing of 350 mm. dia housing clamp 407 supply of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of e / i. 408 filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of e / i. 409 development by air compressor including transportation. 410 development by o.p. unit including transportation. 411 supply of 7.5 hp ksb make submersible pump set model bpd 302 / 4+uami 150 / 6 / 22 203 ( s / d ) suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with ksb electric moter operating of 415 volt suitable for 3 phase 50 cycle a.c. supply of following duty condition 7.5 hp 6 stage pipe.a discharge of water in lpm 860 approx size of discharge outlet in 80 mm.b total head of pump set 45 m. 412 supply of finolex or equivalent isi marked submersible copper cable of size 2x3x2.5 sq. mm. 413 fixing of finolex or equivalent isi marked submersible copper cable of size 2x3x2.5 sq. mm. 414 supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having l&t of qul. male switch fuse unit with hrc fuses, ameter, boltmeter, selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of jyoti or eq. air break star delta motro starter suitable for above submersible pump set. 415 supply of 80mm dia m.s. column pipe of class c both and socketed with heavy sockets in 3 / 6 meter length and one end flanged complete with interlocking arrangements. 416 lowering of 80mm dia m.s. column pipe of class c both and socketed with heavy sockets in 3 / 6 meter length and one end flanged complete with interlocking arrangements. 417 supply of 80mm dia m.s. column pipe clamps with nut, bolts, packing etc. 418 lowering of 80mm dia m.s. column pipe clamps with nut, bolts, packing etc. 419 supply of 80mm dia c.i. double flanged isi mark reflex valve of updadhya or equ. make. 420 fixing ofc.i. double flanged reflex valve 421 supply of 80mm dia c.i. double flanged isi mark sluice valve with hand wheel of upadhya or equ. make. 422 supply of 100 mm dia c.i. double flanged isi mark sluice valve with hand wheel of upadhya or equ. make. 423 supply of 150mm dia c.i. double flanged isi mark sluice valve with hand wheel of upadhya or equ. make. 424 fixing of 80 / 100 / 150 mm dia c.i. double flanged isi mark sluice valve with hand wheel 425 supply of c.i. double flanged bend of 80mm dia 426 fixing of c.i. double flanged bend of 80mm dia i / c cost of labour. 427 supply of 80mm dia c.i. tee heavy quality i / c cost of material. 428 fixing of 80mm dia c.i. tee heavy quality 429 supply of guru / fibing or equivalent make pressure gauge. 430 fixing of pressure gauge. 431 erection & commissioning of pumping plants complete along with electric wiring. 432 supply of steel wire rope of 1 / 2 size 433 fixing of steel wire rope of 1 / 2 size 434 s / b of 600mm x 600 mm x 6.0 mm g.i. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia g.i. pipe and funnel for watering and one earthing lead on one no. 8 to 10 swg gi wite in 15mm dia g.i. pipe up to switch board ( from appron to switch board the cost of g.i. , pipe and g.i. wire will be extra ) 30 cm square c.i. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of e / i complete in all respects as per drawing. 435 s / f of one number 8 to 6 swg g.i. wire in 15mm dia g.i. pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. t&p other material required for proper completion of the work as directed at site. 436 s / f of aluminium conductor pvc insulated armoured, served, sheathed cable 1100 volts grade16 sqmm x 4 core 437 fixing of aluminium conductor pvc insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mmbelow ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top.on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by e / i complete in all respects the armoring of the cable shall be properly connected with the earth conductor by clamps etc.16 sqmm x 4 core 438 supply of 500 kva. 11 / 0.433 kv, 3phase, 50hz, dyn 11, oil type, ( uppcl approved make ) copper wound transformer with off load tap changing arrangement on hv side in steps of + / 2.50%, + / 5% & 7.5% , having cable end boxes on hv sideand 800 amp. bus trunking arrangement on lv side complete with all accessories i / c first filling of filtered dehydrated oil and confirming to is 2026 ( part 1 to part 5 ) & as per specification attached complete in all respects as required at site. 439 installation, testing and commissioning of 500 kva. 11 / 0.433 kv, 3phase, 50hz, dyn 11, oil type, ( uppcl approved make ) copper wound transformer with off load tap changing arrangement on hv side in steps of + / 2.50%, + / 5% & 7.5% , having cable end boxes on hv sideand 800 amp. bus trunking arrangement on lv side complete with all accessories i / c first filling of filtered dehydrated oil and confirming to is 2026 ( part 1 to part 5 ) & as per specification attached complete in all respects as required at site. 440 supply of 3 core standered aluminium conduktor xlpe ( cross linked polyethylene ) insulated pvc bedded, galvanised flat steel strip armoured cables confirming to i.s. 7098 ( part ii with latest amendments ) 11 kv grade 150sq. mm 3 core 441 laying of 3 core standered aluminium conduktor xlpe ( cross linked polyethylene ) insulated pvc bedded, galvanised flat steel strip armoured cables confirming to i.s. 7098 ( part ii with latest amendments ) 11 kv grade at a depht of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks in sides and on the top put across. thearmouring of cable shall be properly connected with earth condutor by clamps etc.150sq. mm 3 core 442 supply of 3 core 240sq.mm. xlpe aluminium conductor cable of 11 kv grage as required. 443 making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 240sq.mm. xlpe aluminium conductor cable of 11 kv grage as required. 444 making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 240 sq.mm. xlpe aluminium conductor cable of 11 kv grage as required. 445 supply and burying of 40mm dia x 4.5 metres long g.i. pipe vertically for earthing having 12mm dia. holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of no. 6 to 8 swg gi wire in g.i. pipe up to appron ( and from appron to switch board the cost of g.i. wire and pipe will be extra ) upto switch board, 30cm square c.i. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal / coke and salt at least 150mm thick alround etc. as per directions of engineer in charge complete in all respects as per drawing. 446 supply and burying of 600mm x 600 mmx6mm g.i. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm g.i.pipe and funnel for watering and two earthing leads of no.8to10swg g.i.wire in 15mm diag.i. pipe upto switch board ( from apron to switch board the cost of g.i. pipe and g.i. wire will be extra ) 30cm. square c.i. frame with hinged cover, masonary housing, alternate layers / of charcoal / coke and salt at least 150mm thick alround etc. complete in all respects. 447 supply and burying of 600mm x 600mm x 3 mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia g.i pipe and funnel for watering and one earthing lead ofone no. 8swg copper wire in 15 mm dia g.i pipe up to switch board ( from appron to switch board the cost of g.i pipe and copper wire will be extra ) 30 cm square c.i frame with hinged cover masonry housingalternate layers of charcoal / coke and salt atleast 150mm thick alround etc. as per directions of engineer in charge complete in all respects. 448 supply and laying of 32mm x 6mm g.i. strip from earth electrode directly in the ground as required complete in all respects. 449 supply and laying of 32mm x 6 mm copper strip from earth electrode directly in the ground as required complete in all respects.. 450 supply and laying of 25mm x 3mm g.i. strip from earth electrode directly in the ground as required complete in all respects. 451 supply and fixing of one number 8 swg g.i wire in 15mm dia. g.i pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, t&p other material required for proper completion of the work as directed at site. 452 supply of aluminium conducter, pvc insulated armoured, served, sheeted cable 1000 bolts grade 453 300 sqmm3.5 core 454 185 sqmm3.5 core 455 150 sqmm3.5 core 456 35 sqmm3.5 core 457 25 sqmm3.5 core 458 16 sqmm4 core 459 10 sqmm4 core 460 16 sqmm2 core 461 10 sqmm2 core 462 6 sqmm2 core 463 laying of aluminium conducter, pvc insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on m.s. clamps etc. of suitable size. from 6 sqmm 2 core to 300 sqmm3.5 core 464 supply of brass nickle plated compression gland for pvc insulated & armoured served sheathed, underground cable including rubber ring etc. complete 465 300 sqmm3.5 core 466 185 sqmm3.5 core 467 150 sqmm3.5 core 468 35 sqmm3.5 core 469 25 sqmm3.5 core 470 16 sqmm4 core 471 10 sqmm4 core 472 16 sqmm2 core 473 10 sqmm2 core 474 6 sqmm2 core 475 fixing of brass nickle plated compression gland for pvc insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. the armouring of the cable shall be properly connected with the earth as per direction of eic. from 6 sqmm 2 core to 300 sqmm3.5 core 476 supply of palm / pin type copper tin plated cables sockets ( lugs ) to the cable leads, insuslating with tape 477 300 sqmm 478 185 sqmm 479 150 sqmm 480 95 sqmm 481 70 sqmm 482 35 sqmm 483 25 sqmm 484 16 sqmm 485 10 sqmm 486 6 sqmm 487 4 sqmm 488 fixing of palm / pin type copper tin plated cables sockets ( lugs ) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of engineer incharge. from 4 sqmmto 300 sqmm 489 supply of 7 mtr gi octagonal pole of approved make ( top dia 70mm, bottom dia 130 mm and base plate 12 mm thik ) having 3mm thikness with single arm bracket ( 1 mtr length ) including the cost of foundation bolts, required t&p complete in all respect. 490 fixing of 7 mtr gi octagonal pole of approved make ( top dia 70mm, bottom dia 130 mm and base plate 12 mm thik ) having 3mm thikness with single arm bracket ( 1 mtr length ) on rcc foundation including the cost of foundation, foundation bolts, excavation & back filling and required t&p complete in all respect. 491 supply of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. confirming to ip 66 and above protection complete in all respect. 492 fixing of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. confirming to ip 66 and above protection complete in all respect. 493 supply of 6 amp to 32 amp dp mcb ( 10ka ) ( c curve ) for poles 494 fixing of 6 amp to 32 amp dp mcb ( 10ka ) ( c curve ) for poles 495 supply of decorative 40 to 45 watt led post top indirect light luminaire having pressure die cast aluminium body and clear glass with driver set confirming to ip 65 and above protection complete in all respect. 496 fixing of decorative 40 to 45 watt led post top indirect light luminaire having pressure die cast aluminium body and clear glass with driver set confirming to ip 65 and above protection complete in all respect. 497 supply offollowing capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contractors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn complete in all respect.25 amp spn 498 fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contractors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn complete in all respect.25 amp spn 499 supply of bakelite sheet 3 mm thick of suitable size & connector 500 fixing of bakelite sheet 3 mm thick of suitable size & connector 501 supply of m.s. pipe ( class b is : 1239 ) pole suitable for fixing 70 watt. hpsv post top including 4 pole cable junction box with 5 amp. rewireablefuse fitting and 5 amp. switch on laminated cover and m.s. box complete with water tight cover and 450x450x450mm base above ground and 2x4sqmm aluminium wire from cable box to lamp for connection including painting the pole on primer coats and necessary reducers on thetop of pole for fixing of post top lantern. 65mm dia 4m long ( 3m above ground and 1 m below ground ) . 502 fixing of m.s. pipe ( class b is : 1239 ) pole suitable for fixing 70 watt. hpsv post top including 4 pole cable junction box with 5 amp. rewireablefuse fitting and 5 amp. switch on laminated cover and m.s. box complete with water tight cover includingmasonary / pcc ( 1:3:6 ) work for erecting the pole and 450x450x450mm base above ground and 2x4sqmm aluminium wire from cable box to lamp for connection including painting the poleby an approved shade on primer coats and necessary reducers on thetop of pole for fixing of post top lantern.the work shall be complete as required up to the satisfaction of engg. in charge.65mm dia 4m long ( 3m above ground and 1 m below ground ) . 503 making of following size of cable chamber made of 230 mm thick brick work in cement mortar ( 1 cement : 6 sand ) with pcc 100 mm thick pcc base plastering of inner and outer surface with cement mortar including providing of heavy duty c.i cover complete with digging, refilling and removal of surplus soil complete as required. material cost will be paid saperately.900 mm x 900 mmx 1000 mm deep 504 supply of mv danger notice plate of 200 mm x 150 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required. 505 supply of ht danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required. 506 fixing of mv / ht danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required. 507 supplying of fire buckets, round bottom made of g.i. sheet 9 11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of engineer in charge. 508 fixing of fire buckets, round bottom made of g.i. sheet 9 11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of engineer in charge. 509 supply of 1800 mm x 900 mm x 12 mm thick chequered rubber matting of tested quality 510 layingof 1800 mm x 900 mm x 12 mm thick chequered rubber matting of tested quality 511 supply of danger board fabricated from 10 gauge ms sheet as per ie rules 512 fixing of danger board fabricated from 10 gauge ms sheet as per ie rules 513 supply of shock treatment chart ( prescribed under i.e.rules ) duly framed with glass and supported from back with hard board or soft board. 514 fixing of shock treatment chart ( prescribed under i.e.rules ) duly framed with glass and supported from back with hard board or soft board with supply of all labour t & pfor proper completion of work. 515 supply of fire extinguishers, abc type 4.00 kg. capacity ( isi marked is : 15683 & tac approved ) complete with initial charges and wall bracket, 516 supply of co2 typefire extinguishers, 4.50 kg. capacity ( isi marked is : 2878 & tac approved ) complete with initial charges and wall bracket, 517 fixing of fire extinguishers, abc type 4.00 kg. & co2 type 4.5 kg. capacity complete with initial charges and wall bracket, along with supply of all labour for proper completion of work. 518 supply of water closet squatting pan ( indian type w.c. pan ) with 100mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern with manually controlled device ( handle lever ) conforming to is:7231, parryware / hindware / seabird / orient ( coral ) with all fittings and fixtures complete.white vitreous china orissa pattern w.c. pan of size 580x440mm with integral type foot rests 519 fixing of water closet squatting pan ( indian type w.c. pan ) with 100mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern with manually controlled device ( handle lever ) conforming to is:7231, parryware / hindware / seabird / orient ( coral ) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.white vitreous china orissa pattern w.c. pan of size 580x440mm with integral type foot rests 520 supply of white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern with manually controlled device ( handle lever ) , conforming to is : 7231, parryware / hindware / seabrid / orient ( coral ) with all fittings and fixtures complete.w.c. pan with isi marked black solid plastic seat and lid 521 fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern with manually controlled device ( handle lever ) , conforming to is : 7231, parryware / hindware / seabrid / orient ( coral ) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : w.c. pan with isi marked black solid plastic seat and lid 522 supply of white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) , including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 523 fixing of white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) , including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 524 supply of white vitreous china wash basin with c.i. brackets painted white, 15 mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mm c.p. brass waste of standerd pattern. 525 a ) white vitreous china wash basin size 630x450 mm with a pair of 15 mm c.p. brass pillar taps 526 b ) white vitreous china surgeon type wash basin of size 660x460 mm with single 15 mm c.p. brass pillar tapswith elbow operated levers isi marked 527 fixing of white vitreous china wash basin with c.i. brackets painted white, 15 mm c.p. brass pillar taps, c.p. brass chain with rubber plug, 32mm c.p. brass waste of standerd pattern including cutting & making good the walls wherever required. 528 a ) white vitreous china wash basin size 630x450 mm with a pair of 15 mm c.p. brass pillar taps 529 b ) white vitreous china surgeon type wash basin of size 660x460 mm with single 15 mm c.p. brass pillar tapswith elbow operated levers isi marked 530 supply of p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete. 531 semi rigid pipe 532 32 mm dia 533 40 mm dia 534 fixing of p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete. 535 semi rigid pipe 536 32 mm dia 537 40 mm dia 538 supply of 600x450mm bevelled edge mirror of superior glass ( of approved quality ) complete with 6mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 539 fixing of 600x450mm bevelled edge mirror of superior glass ( of approved quality ) complete with 6mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 540 supply of stainless steel aisi 304 ( 18 / 8 ) kitchen sink as per is : 13983 with c.i. brackets and stainless steel plug 40mm including painting of fittings and brackets, kitchen sink with drain board size 510x1040 mm bowl depth 250mm 541 fixing of stainless steel aisi 304 ( 18 / 8 ) kitchen sink as per is : 13983 with c.i. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required.kitchen sink with drain board size 510x1040 mm bowl depth 250mm 542 supply of white vitreous china flat back half stall urinal of size 580*380*350mm with white pvc automatic flushing cistern, with fittings, standard size c.p. brass flush pipe, spreaders with unions and clamps ( all in d.p. brass ) with waste fitting as per is : 2556, c.i. trap with outlet grating and other couplings in c.p. brass including painting of fittings. 543 range of three half stall urinals with 10 litre pv.c. automatic flushing cistern. 544 range of two half stall urinals with 5 litre pv.c. automatic flushing cistern. 545 range of single half stall urinals with 5 litre pv.c. automatic flushing cistern. 546 fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white pvc automatic flushing cistern, with fittings, standard size c.p. brass flush pipe, spreaders with unions and clamps ( all in d.p. brass ) with waste fitting as per is : 2556, c.i. trap with outlet grating and other couplings in c.p. brass including painting of fittings and cutting and making good the walls and floors wherever required: 547 range of three half stall urinals with 10 litre pv.c. automatic flushing cistern. 548 range of two half stall urinals with 5 litre pv.c. automatic flushing cistern. 549 range of single half stall urinals with 5 litre pv.c. automatic flushing cistern. 550 fixing of stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 ( 1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size ) as per direction of engineer in charge and finished smooth.granite stone of approved shade 551 supply of unplasticised pvc connection pipe with brass unions 552 45 cm length 553 15 mm nominal bore 554 fixing of unplasticised pvc connection pipe with brass unions 555 45 cm length 556 15 mm nominal bore 557 supply of c.p. brass bib cock of approved quality conforming to is:8931 a ) 15 mm nominal bore 558 fixing of c.p. brass bib cock of approved quality conforming to is:8931v a ) 15 mm nominal bore 559 supply of c.p. brass long body bib cock of approved quality conforming to is standards andweighing not less than 690 gms.a ) 15 mm nominal bore 560 fixing of c.p. brass long body bib cock of approved quality conforming to is standards andweighing not less than 690 gms.a ) 15 mm nominal bore 561 supply of c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is:8931a ) 15 mm nominal bore 562 fixing of c.p. brass angle valve for basin mixer and gyser points of approved quality conforming to is:8931a ) 15 mm nominal bore 563 supply of c.p. brass shower rose with 15 or 20mm inlet 150 mm diameter 564 fixing of c.p. brass shower rose with 15 or 20mm inlet150 mm diameter 565 supply of c.p. brass stop cock ( concealed ) of standard design and of approved make conforming to is:8931: 150 mm diameter 566 fixing of c.p. brass stop cock ( concealed ) of standard design and of approved make conforming to is:8931: 150 mm diameter 567 supply of ptmt bottle trap for wash basin and sink.bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 568 fixing of ptmt bottle trap for wash basin and sink.bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 569 supply of ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 570 fixing of ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 571 supply of ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms 572 fixing of ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms 573 supply of unplasticised pvc pipe clips of approved design to unplasticised pvc pipes by means of 50x50x50 mm hard wood plugs, screwed with ms screws 574 110mm 575 90mm 576 fixing of unplasticised pvc pipe clips of approved design to unplasticised pvc pipes by means of 50x50x50 mm hard wood plugs, screwed with ms screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 577 110mm 578 90mm 579 laying of cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size ) around p.v.c soil and waste pipe including bed concrete as per standard design ( embedded in the flooring / ground ) 580 100 / 75 mm dia 581 supply of wall face unplasticised rigid pvc rain water pipes conforming to is: 13592 type a110 mm 582 fixing on wall face unplasticised rigid pvc rain water pipes conforming to is: 13592 type a including jointing with seal ring conforming to is: 5382 leaving 10mm gap for thermal expansion. 110 mm 583 supply of wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is:13592. 584 bend 87.5 degree 585 110 mm bend 586 shoe ( plain ) 110 mm shoe 587 fixing of wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is:13592type a including jointing with seal ring conforming to is:5382 leaving 10mm gap for thermal expansion. 588 bend 87.5 degree 589 110 mm bend 590 shoe ( plain ) 110 mm shoe 591 supply of inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 592 fixing of the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 593 supply of unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with ms screws of required length. 110 mm 594 fixing of unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with ms screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete.110 mm 595 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over pvc sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, punning, rounding the edges and making and finishing the outlet complete. 596 supply of chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i / c fixing the pipe with clamps at 1.00m spacing. 597 20mm dia nominal outer dia pipes 598 25mm dia nominal outer dia pipes 599 32mm dia nominal outer dia pipes 600 fixing of chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i / c fixing the pipe with clamps at 1.00m spacing.this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of engineer in charge. 601 concealed work including cutting chases and making good the walls etc. 602 20mm dia nominal outer dia pipes 603 25mm dia nominal outer dia pipes 604 32mm dia nominal outer dia pipes 605 supply of gi pipes complete with gi fittings and clamps. 606 15mm dianominal bore 607 20mm dianominal bore 608 25mm dia nominal bore 609 32mm dia nominal bore 610 40mm dia nominal bore 611 50mm dia nominal bore 612 65mm dia nominal bore 613 fixing of gi pipes complete with gi fittings and clamps, including cutting and making good walls etc. ( internal work ) . internal work exposed on wall 614 15mm dianominal bore 615 20mm dianominal bore 616 25mm dia nominal bore 617 32mm dia nominal bore 618 40mm dia nominal bore 619 50mm dia nominal bore 620 65mm dia nominal bore 621 painting of gi pipes and fittings with synthetic enamel paint over a ready mixed priming coat, both of approved quality for new work. 622 15mm dia nominal bore 623 20mm dia nominal bore 624 25mm dia nominal bore 625 32mm dia nominal bore 626 40mm dia nominal bore 627 50mm dia nominal bore 628 65mm dia nominal bore 629 supply of gi union in gi pipes 630 15mm dia nominal bore 631 20mm dia nominal bore 632 25mm dia nominal bore 633 32mm dia nominal bore 634 40mm dia nominal bore 635 50mm dia nominal bore 636 65mm dia nominal bore 637 fixing of gi union in gi pipes including cutting and threading the pipe and making long screws etc. complete ( new work ) . 638 15mm dia nominal bore 639 20mm dia nominal bore 640 25mm dia nominal bore 641 32mm dia nominal bore 642 40mm dia nominal bore 643 50mm dia nominal bore 644 65mm dia nominal bore 645 supply of gun metal gate valve with wheel of approved quality. 646 25mm dia nominal bore 647 32mm dia nominal bore 648 40mm dia nominal bore 649 50mm dia nominal bore 650 65mm dia nominal bore 651 fixing of gun metal gate valve with wheel of approved quality. 652 25mm dia nominal bore 653 32mm dia nominal bore 654 40mm dia nominal bore 655 50mm dia nominal bore 656 65mm dia nominal bore 657 supply of brass stop cock of approved quality. 658 b ) 20 mm nominal bore 659 fixing of brass stop cock of approved quality. 660 b ) 20 mm nominal bore 661 supply of terrace ( at all floor levels ) polyethylene water storage tank isi : 12701 marked indicating the bis license no. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank. [ sintex, electroplast, star, lotus or equivalent having valid isi license ] . 662 fixing & placing of terrace ( at all floor levels ) polyethylene water storage tank isi : 12701 marked indicating the bis license no. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank. [ sintex, electroplast, star, lotus or equivalent having valid isi license ] . 663 supply of glazed stoneware pipes grade a100mm dia sw pipe 664 laying and jointing glazed stoneware pipes grade a with stiff mixture of cement mortar in the proportion of 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete.100mm dia sw pipe 665 laying cement concrete 1:5:10 ( 1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size ) all rounds.w. pipes including bed concrete as per standard design 100mm dia sw pipe 666 supply of square mouth s.w. gully trap grade‘a’ complete with c.i. grating, water tight c.i. cover with frame of 300 x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size p type 667 fixing of square mouth s.w. gully trap grade‘a’ complete with c.i. grating, brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design150 x 100 mm size p type 668 supply of floor and wall face ringfit upvc astral ultradrain conventional system for soil and waste water pipes conforming to ( hsn code: 3917 ) type b ( i ) double socketed pipes. 669 a ) 110mm dia p.v.c. pipe 670 b ) 90mm dia p.v.c. pipe 671 fixing of floor and wall face ringfit upvc astral ultradrain conventional system for soil and waste water pipes conforming to ( hsn code: 3917 ) type b including jointing with seal ring. ( i ) double socketed pipes. 672 a ) 110mm dia p.v.c. pipe 673 b ) 90mm dia p.v.c. pipe 674 supply of upvc floor trap of self cleansing designwith cp jalicomplete in all respects. ( make : supreme / finolex / prince ) p trap type floor trap 110 x 90mm 675 fixing of upvc floor trap of self cleansing designwith cp jalicomplete in all respects. ( make : supreme / finolex / prince ) p trap type floor trap 110 x 90mm 676 supply of clean out plug ( astral ) 677 fixing of clean out plug ( astral ) 678 supply ofterminal guard. 679 a ) 110mm 680 b ) 90mm 681 fixing of terminal guard. 682 a ) 110mm 683 b ) 90mm 684 supply of wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes. 685 110mm bend 686 90 mm bend 687 110mm coupler 688 90mmcoupler 689 110x110x110 mm single tee with door 690 90x90x90 mm single tee with door 691 fixing of wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 692 110mm bend 693 90 mm bend 694 110mm coupler 695 90mmcoupler 696 110x110x110 mm single tee with door 697 90x90x90 mm single tee with door 698 supply of 1.50 sqmm frlsh pvc insulated single core copper conductor cable 699 supply of 2.50 sqmm frlsh pvc insulated 1100 v single core multistrand copper conductor cable 700 supply of 4.00 sqmm frlsh pvc insulated 1100 v single core multistrand copper conductor cable 701 supply of 6.00 sqmm frlsh pvc insulated 1100 v single core multistrand copper conductor cable 702 supply of 10 sqmm frlsh pvc insulated 1100 v single core multistrand copper conductor cable 703 supply of 16 sqmm frlsh pvc insulated 1100 v single core multistrand copper conductor cable 704 supply of 25 sqmm frlsh pvc insulated 1100 v single core multistrand copper conductor cable 705 supply of hexagonal / round gp fan box of approved make made up of 1 mm thick isi marked gp sheet spot welded four to eight holes of 25.4 mm for pipe entry of the box duly screewed fitted with 300 mm round zink coated ms bar x 12 mm. 706 supply of ceiling fan with fan motor of ac permanent insulation, capacitor rating conforming to bee 5 star. the ratrd voltage220 / 240 volts, 50 hz, single phase, ac the fan assemble should consists of down road blades, shackle canopies with double ball bearing system – 1200 mm sweep 707 supply of electronic fan regulator ( modular ) 120 280 v isi marked 708 supply of led tube light with metal heavy duty box type batten light fitting 2x 22 watt suitable for 2x22 watt polycarbonate tube light including tube etc suitable for both surface. 709 supply of led tube light with metal heavy duty box type batten light fitting 1x 22 watt suitable for 1x22 watt polycarbonate tube light including tube etc suitable for both surface. 710 supply of recess / surface mounting round 10 to 15 watt, cut out 125 mm, height min 40 mm, led downlighter having powder coated die cast aluminium housing with heat sink, diffuser / reflector and driver set, suitable for 24 hr continuousoperation 711 supply of single led light wall bracket on matching mdfeg board base 712 water tight oblong 10 watt led bulkhead luminery with driver set conforming to ip 65 and above protection complete. 713 supply of surface / flush mounting distribution boards with additional metal door without mcb complete. ( cat a ) 714 4 way tpn 715 6 way tpn 716 8 way tpn 717 supply of 6 amp to 32 amp ( 10 ka ) sp mcb ( cat a ) 718 supply of following mcbs 719 40 amp. fp mcb ( cat a ) 720 63 amp. fp mcb ( cat a ) 721 40 amp. tp mcb ( cat a ) 722 63 amp. tp mcb ( cat a ) 723 supply of surface / flush mounting v tpn distribution boards with additional metal door without mcb complete. 4 way v tpn 724 supply of following mccbs 725 63 amp. fp mccb ( cat a ) 726 100 amp. fp mccb ( cat a ) 727 125 amp. fp mccb ( cat a ) 728 160 amp. fp mccb ( cat a ) 729 supply of power plug with 15 a / 250 v flush type switch and 5 pin 15 a / 250 v flush type universal socket in suitable ms box 175mmx100mmx50mm size ( modular ) 730 supply of single pole mcbs blanking plate complete 731 supply of gi plate for earthing size 600 mm x 600mm x 6 mm 732 supply of gi pipe 20 mm dia 733 supply of gi wire 8 to 10 swg 734 supply of ci frame ( 30 sqcm ) with hinged cover 735 supply of gi strip for earthing purpose 25 mmx 3 mm 736 supply of aluminium conductor pvc insulated armoured, served, sheeted cable 1000 volts 737 95 sqmm 3.5 core 738 70 sqmm 3.5 core 739 50 sqmm 3.5 core 740 35 sqmm 3.5 core 741 25 sqmm 3.5 core 742 10 sqmm 4 core 743 supply of brass nickle plated compression gland for pvc insulated and armoured served sheeted underground cable including rubber ring 744 95 sqmm 3.5 core 745 70 sqmm 3.5 core 746 50 sqmm 3.5 core 747 35 sqmm 3.5 core 748 25 sqmm 3.5 core 749 10 sqmm 4 core 750 supply of palm / pin type copper tin plated cable sockets ( lugs ) to the cable leads, insulating with tape 751 95 sqmm 752 70 sqmm 753 50 sqmm 754 35 sqmm 755 25 sqmm 756 16 sqmm 757 10 sqmm 758 6 sqmm 759 supply of gi box alonwith modular base and cover plate for modular switches in recess1 or 2 module ( 75 mmx75 mm ) 760 supply of telephone socket outlet ( modular ) 761 supply of tv antenna socket outlet ( modular ) 762 supply of bell push ( modular ) 763 supply of call bell / buzzer suitable single phase 230 v 764 supply of telephone cable following pair 0.5 sqmm fr pvc insulated annealed copper conductor, unarmoured 765 2 pair 766 10 pair 767 20 pair 768 supply of co axial tv cable rg 6 grade 0.7 mm solid copper conductor pe insulated sheeted with fine tinned copper braid and protected with pvc sheet 769 supply of 10 pair junction boxes for floors and building with krone connectors 770 supply of 20 pair junction boxes for floors and building with krone connectors 771 supply of 50 pair junction boxes for floors and building with krone connectors 772 supply of exhaust fan of ac 230 / 250 v, 50 hz including nuts & bolts, mounting frame and other accessories.300 mm sweep 773 supply of energy meter ( 3 phase ) and other accessories. 774 supply of wall fanof ac 230 / 250 v, 50 hz including nuts & bolts, mounting frame and other accessories. 450 mm sweep 775 supply of exhaust fan of ac 230 / 250 v, 50 hz including nuts & bolts, mounting frame and other accessories.450 mm sweep 776 supply of weired decorative mirror light suitable 9 watt led with lamp complete 777 supply of factory weired integral led flood light luminaries with die cast aluminium housing built with driver set suitable for 40 to 50 watt confoming to ip 65 / 66 protection complete. 778 supply of swiches ( modular ) 5 amp 779 supply of sockets ( modular ) 5 amp 780 supply of pvc conduit pipe 25 mm dia 781 supply of round sheet 782 supply of ceiling rose 783 supply of holder for bulbs 784 fixing of main lt panel 785 fixing of main em panel 786 fixing of sub panel 787 fixing of sub em panel 788 fixing of capacitor panel 150kvar 789 fixing of feeder piller 790 fixing of street feeder piller 791 supply of coarse sand 792 supply of cement50 kg 793 supply of brick m150 794 supply of stone grit 20 mm 795 supply of stone ballast 40 mm 796 supply of tor steel 8 mm dia 797 supply of tor steel 10 mm dia 798 supply of tor steel 12 mm dia 799 supply of tor steel 16 mm dia 800 supply of tor steel 20 mm dia 801 supply of tor steel 25 mm dia 802 supply of ms fabrication for door window and ventilator 803 supply of water proofing chemical cico tapecrete p151 804 supply of y shaped angle iron post 40x40x6 805 supply of kota stone 22 mm thick 806 supply of vitriried floor tile 8 to 10 mm thick in 600x600 mm size 807 supply of wall tile glazed / ceramic floor tiles 808 supply of ss railing 304 grade 809 supply of ms collapsible channel 810 supply of rolling shutter with ball bearing 811 supply of granite 812 supply of cinder 813 supply ofchequred tile 300x300 mm size 814 supply of ms gate made of ms hollow sections 815 supply of interlocking pavers 80 mm m30 mpa...
36875089 provision of water supply (boring/bore well) at temple location , non consumable items , boring/drilling bore well of required dia. approx. 4 inch and 140 feet depth,for casing/ strainer pipe, by suitable method including starter panel and water pump of 3hp, cables, columns pipes adapter, safety wire, strainer etc. complete in all respect....
36760073 bids are invited for mist chamber, shed net house, genset, bore well with pump for irrigation, water tank, compost unit, sprinkler unit...
36757089 repairing of bore well dia. 10inch of wtp 2 ( 1000kl / day ) ...
36750660 bids are invited for mist chamber, shed net house, genset, bore well with pump , water tank, sprinkler unit...
36559124 survey and valuation work of structures located within proposed right of way ( prow ) & existing right of way ( erow ) as per joint measurement survey ( jms ) including all the affected structures and any other value ( valuation of trees, affected structures, hand pumps, wells / bore wells etc ) in co ordination with concerned government departments of km 0.000 to km 49.200 of nh 731b in the state of uttar pradesh. ( pkg i ) ...
36410574 repair for replacement of old vintage bore well no. 3 in domestic area at af station sarsawa under ge ( af ) sarsawa...
36342601 repairing 01 no bore well at gc crpf rampur u.p....
36277085 provision of borewell in tech area and upgradation of stores at various location at north camp under ge ( af ) bamrauli trial bore well of 200 mm dia size pilot bore through any soil strata including hard stone / boulder by means of directrotary method below ground level complete all as specified & directed by engineer in charge. note: unit rate quoted by tender shall be deemed to include cost of ms pipe and transportation of rig accessories required, developing and testing etc at site of work and removal of the same on completion from the site including necessary supervision and rent charges of rig machine compressor & op unit ( any other t&p not specifically mentioned ) in respective item of sch aand no extra payment shall be admissible on this account. 2 drilling reaming vertical bore 525 mm dia at approved site / location in any type of strata for 250erw casing pipe for various depth as shown below including all works pertaining to boring complete in all respect and all as specified & directed. 3 ( a ) reaming up to 525 mm dia for 60 mtr depth from ground level for casing pipe 250 mm dia. 4 ( b ) reaming up to 525 mm dia for exceeding 60 mtr to 150 mtr for casing pipe of 200 mm dia. 5 supply and assembly including jointing, lowerings and fixing in position erw plain steel pipe ( seamless ) housing pipe 250 mm bore ( nominal dia ) 8.00mm thick and outer dia of pipe 266 mm conforming to is 8110 2000 class 8.1.1 plain end pipe jointed and welded couper ring ( welding shall be done through out the circumference of the pipe and coupler ring both sides all as specified and directed by eic. make : jindal / tata. note : ( a ) length of pipe shall not less than 2.40 mtr except where the pipe length required is less than 2.40m ( b ) effective length shall only be measured and paid. 6 all as per item no 3 above but supply assembling, jointing plain ms pipe ( seamless ) casing 200 mm bore 8 mm thick and outer dia of pipe 216 mm conforming to is 8110 2000 complete and lowering and fixing position after socket reducer of 250x200mm bore. 7 s&f ms strainer ( slotted ) pipe v weired 200 mm bore, 8 mm thick conforming to is 8110 2000 fabricated with pipe or specification mentioned above ( item no 3 ) slot of size 1.55mmx75mm as per is provn uniformly distributed on the surface all as specified. 8 s&f mild steel reducing socket 250mmx200mm dia of suitable length including welding, mild steel strip 40x6mm 2 nos on each joint extended in 75mm on each side all as specified. ( the wall thickness of socket not less than 8 mm thick. 9 s&f wrought iron bail plug 200 mm bore, all as specified. 10 s&f well cap for 266 mm dia housing pipe all as specified and directed. 11 s&f two nos ms flat iron 150 mm x 15 mm housing clamp for holding to 250 mm dia housing pipe with 16mm ms bolt & washers including casting of pcc blocks 1:2:4 type b 1 using 20mm graded stone aggregate of size 1.20 m x 1.00 m including 50mm dia ms pipe 2 nos each 1.5mtr long with cap plug and cap top for filling pea gravel including necessary excavation & each work in any type of soil complete all as specified and directed. 12 m&l for packing pea gravel of size 3 to 5mm natural shape brought direct from river bank and packing around casing pipe to entire depth up to ground level all as specified anddirected. ( length of assembly packed only be measured for payment ) 13 development of tube well by means ofhigh velocity compressored airwith 350 psi air compressor all as specified in is 11189 1985 para 4.2including arrangment for equipment fitting. 14 supply of sodium meta hexa phosphate for disinfecation of bore well all as specified and directed. 15 development of tubewell bymeans of over pumping for subsequent hours until clear discharge as per clause 9.3.2 of is 2800 ( part 1 ) 1991all as specified and directed. 16 supply only strata sample box with glass cover 3mm thick and having internal dimension 1.0 mtr x 0.60 mtr x 0.10 mtr made out of shisham plank 20mm thick with hinges, hasp and staples including polishing complete with samples at various depth met at the time of boring including stata chart in duplicate. 17 chemical bilogical and potability testing of water sample taken from the bore at govt approvedlaboratories. note: test certificate obtained from approved lab will be submitted by the contractor in original. 18 yield testing for bore well by continuous pumping for 16 hrs to determine safe pumping yield of the tube well as perclause 5 of is 2800 ( part ii ) 1979 complete all as specified and directed. 19 electric logging in trial bore precise delineation of granular zones and also the quality of ground water including report interpreatation complete all as specified and directed. note: electric logging shall be carried out by approved agency. 20 s&f air release valve suitable to connect column pipe of rising main flanged and column pipe or submersible pump set compelte with nut, bolt washer etc including grouting 4 bolt on pcc plateform all specified 21 supply, lowering, jointing and testing ms black column pipe 3 mtr long heavy duty 100 mm bore wall thickness 5 mm both ends flanged with heavy duty ms flanged not less than 16 mm screwed and welded in side and outside. the flanged end making surface shall be smooth including welding of 04 strip of 5 mm thick 25 mm wide and 50 mm long covering pipe and flanged, both end flanged having 08 nos predrilled hole not less than 16 mm including rubber gasket, nut bolts and washer, pipe should be duly painted with anti corrosive paint complete all as specified and directed. 22 supply, fixing, jointing and testing of cast iron non return valve 100 mm dia flanged ends as per is 5312 ( isi marked ) complete with washer nuts / bolts and rubber gasket complete all as specified and directed. 23 supply, fixing, jointing and testingof cast iron sluice valve 100 mm class i ( isi marked ) pn 1 typelatest is 14846 2000 flanged ends, drilled having stainless steelspindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etccompleteall as specified and directed. 24 supply, installation, commissioning and testing submersible pumping setmulti stage electric driven of 10 hp capacityat operating head range 10 40 mtr head, directly coupled with electric motor, ac 3 phase, 415 volts, 50 hz, 2900 rpm with copper wound water proof winding complete with flange adoptor suitable for connection with 100 mm dia flanged column pipe and one set of essential tool with price list, literature as recommended by manufacture complete complete all as directed. 25 s&f submersible pump controller in sheet enclosure type mu g20 fully autimaticstar delta starterfor threephase motor 415 volts, 50 hz, 3 phase, 15 hp, 9 14 amps relay range all as specifiedmake : l&t cat part no. :ss95984coaoor equivalent 26 s&f in replacement of pvc insulated flat copper submersible cable heavy duty 16 sqmm 3 core 1100 volt grade of the following size complete all as specified and directed. make havells / plaza / finolex 27 supply and fix high pressure single head adjustable chlorine dosing system including frp pressure dosing tank of capacity 100 ltrs consisting of water inlet line, outlet with y strainer, drian, overflow, conical bottom for sludge deposition , pot hole with cover, level gauage with agitation motor 120 watts 960 rpm, single phase flange mounted motor with plastic shaft and impeller connected to frp service dosing tank of capaicty 100 lts consisting of water inlet line, dozing injector 230v, 50hz including on / off switch and stokes / minute of max 135 min. 15 with motor, discharge pressure 10kg / sqcm, high flow rate of 0 25 lph including drain, overflow level gauge, inspection port, agitator motor 120 watts 960 rpm single phase flange mounted with plastich shaft and impeller including mounting lid, complete all as directed. make: aquafit or equivalant 28 supply & laying in trenches ductile iron ( di ) pipe of size 100 mm bore dia with spigot and socketed ends centrifugally cast class k 7 in any length laid in trenches including di fittings and jointing materails complete all as specified and directed. 29 m&l for 100 mm bore cast iron ( di ) fittings such as bends ( any type, radius and angle ) tapers any type, ( straight, bend, increasing, decreasing or double socket etc ) tee pieces single branch, “y” junction, double branch, cross ( all sockets or socket and spigot ) collars, caps and plugs complete all as specified and directed. 30 supply and lay steel water tubing gi medium grade isi marked with all fittings laid in trenches or fixed to wall etc complete for the following sizes: make: jindal / prakash / swastik note : excavation and earth work will be measured and paid separately. 31 ( a ) 40 mm dia bore 32 ( b ) 25 mm dia bore 33 s&f gun metal gate valve isi marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves. make : zoloto / seico / jindal / upadhaya / venus 34 ( a ) 40 mm bore 35 ( b ) 25 mm bore 36 supply, install, testing and commissioning of busbar chamber of size not less than 60cm x 60cm x 25cm for 3 phase, 415 volts ac, outdoor type, cubical compartmentalised type, weather, vermin and water proof, fabricated out of 2 mm thick crca sheet powder coated front door openable with locking arrangemen and iron angleframe bottom of the panel board including 100 amps mccb , rated copper bus bar, phase indicator , 15 amps switch socket combined , grouted using pcc foundation 1:2:4 type c1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painted over a coat of red oxide primer complele all as specifed and directed. 37 m&l for earthing complete with galvanized steel earth plate 600x600x6mm thick buried directly in ground ( earth ) pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, gi pipe light grade 40mm bore for protection of gi strip from earth electrode to and including the earth test point of galvanised iron / steel of size 75mm x 75mm x 25mm, supplying and laying charcoal stone aggregate ) chamber and mild steel angle iron frame 40x40x3mm and rcc cover 40mm thick ( 1:2:4 ) type b 1 using 20mm graded crushed stone aggregate reinforced with 8mm dia tmt bars @ 75mm o / o both ways with mild steel handle 12mm dia, pgi funnel with wire mesh, 20 mm dia gi pipe light grade for watering all as shownin electrical plate no.3 of mes ssr part 1 38 supply, laying and testing cable xlpe insulated , screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 25 sq mm 4 core all as specified. 39 m&l for boring of holes of 200 mm dia under the road / hard standing by horizontal boring method 2 mtr below the surface for fixing requiste 2 nos. all equipments & machinery required to carry out the work will be provided by the contractor ( if due to any obstruction during boring, reboring has to be done the same will be done by the contractor at his own cost the rates deem to cover the same ) complete all as specified and directed. 40 supply and laying sub class b bricks ( old size ) laid flat in trenches as cable covers all as specified and directed 41 excavation in trenches not exc 1.5 m wide and not exc1.5 m in depth and getting out in soft / loose soil as in foundation all as required and directed 42 m&l for returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as directed. 43 removal excavated material ( soil ) not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as directed. 44 m&l for cement concrete 1:2:4 type b 2 ( using 40mm graded stone agg ) 100 mm thick as in floor and finish concrete surface even and smooth without using extra cost, complete all as specified. 45 m&l for cement concrete 1:4:8 type d 2 ( using 40mm graded stone agg ) 100 mm thick as in floor, complete all as specified. 46 m&l for rcc ( m 25 design mix ) ( 20mm graded stone aggregate ) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc basement slabs, under reamed piles and mass concreate etc complete all as specified and directed. 47 m&l for rcc ( m 25 design mix ) ( 20mm graded stone aggregate ) as in columns, pillars, posts and struts etc complete all as specified and directed. 48 m&l for form work to sides of concreate foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation and plinth beams, and similar works vertical or to batter on fair finished surfaces foundation 49 m&l for form work to sides of columns, pillars, posts, struts, piers and stanchions on fair finished surfaces 50 s&f for 10 dia and over mild steel tmt reinforcement bars and spacers cut to length, bent to shape required including cranking, bending, blinding with and including mild steel wire ( annealed ) not less than 0.9 mm dia and necessary welding to reinforcement complete all as specified and directed. 51 s&f for 5 dia and over upto including 10 mm dia mild steel tmt reinforcement bars as in stirrups, spacers and blinders etc complete all as specified and directed. 52 m&l for rendering 10 mm thick in cement mortar ( 1:4 ) on fair faces or brick work or concrete surfaces, finished even and smooth without using extra cement and mixed with water proofing compound @ 3% by weight of cement. ( note: wpc will be measured and paid seperately ) 53 m&l for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer etc complete all as specified. 54 s&f roof trusses ( framed ) , trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing ( beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc complete all as specified and directed. 55 m&l for valve pit chamber of size 1050mm x 1050mm x 1050mm ( internal dimention ) complete including excavation and earth work, pcc 1:4:8, type d 2 using 40mm graded stone aggregate, brick work in cement mortar 1:6, plastering in cement mortar 1:4 ( internally ) and including 3mm thick mild steel sheet cover and painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 56 demolition of cement concrete ( un reinforced ) in ground floors and pavings not exceeding 15cm thickness ( below and above ground level ) and removing the unserviceable materials to a distance not exceeding 100m all as specified and as directed. 57 m & l for pcc 1:2:4 type b2 using 40 mm graded stone aggregate as in sub base / mass concrete complete all as specified and directed. 58 m & l for 20 to 25 mm thick machine cut kota stone slab flooring, landing, steps and plateformover and including 20mm thick screed bed in cement mortar 1:4, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing andgrinding and polishingto achive mirror finish complete all as specified and directed. 59 m & lfor 20 to 25 mm thick machine cut kota stone slab on vertical surfaces such as skirting, risers of step, dado etcover and including 10mm thick bearing plaster in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and granite polishing complete all as specified and directed. 60 s&f framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or othercovering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides ) andhanging; also fastening and fixing complete 61 m&lfor pcc ( 1:2:4 ) type b 1using20 mm gradedstone aggregates as in filling on holes in walls, bed block for inserting hold fast and copingincluding necessary form workcomplete all as specified and directed. { the rate is deemed to be inclusive of form work } 62 excavation over area, n exc 1.50 mtr deep and getting out in soft loose soil complete all as specified and directed 63 removing excavated soil exc 1.50 km but n. exc 5 km and deposited wherever directed 64 m&l for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified as directed. 65 m&l for pcc 1:2:4 type b 2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified as directed. 66 m&l for pcc 75mm thick type c 1 , 1:3:6 using 20mm graded stone aggregate as in plinth protection complete all specifiedas directed. 67 supply onlyglass dividing strips 38 mm wide fixed in floorcomplete all as specified and directed 68 demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed. 69 m&l for brick work with sub class b modular brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete. 70 taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed 71 m&l for 15mm thick rendering in cm 1:3 on surfaces of brick, concrete wall, chajja surface finished even and smooth using extra cement with 2% wpc by weight of cement, appling two coat of polymer modified and cementitious, elastomemric waterproofing coating 1mm thick shall measure and paid seprately under respective item of as supply only complete all as specified and directed 72 supply only liquid water proofing compound 73 m&l for 15mm thick rendering in cm 1:4 on fair faces of brick work, surfaces finished even and faircomplete all as specified and directed 74 m&l for rendering 5 mm thick on concrete surfaces in ceiling , in cement and sand mortar 1:3top surfaces finished even and smooth without using extra cement complete all as specified 75 m&l for preparation of new plastered or unplastered surafces of ceilings and applying three coats of white wash on ceilingincluding washing floors, cleaning glass, joinery, electrical fittings, wiring etc. , of drops and splashes complete all as specified . 76 m&l for preparation of new plastered surface of wall and applying three coats of whitewash on surface of wall incl cornice etc complete all as specified and directed 77 m&l for brooming down plastered or unplastered old decoratedsurface of wall incl cornice etc and applying two coat of whitewash complete all as specified and directed 78 taking down chowkhats or frames n. exc 1.5 sqm each ( without taking off shutter from the frame ) complete. 79 all as per srl item no 72but exc. 1.5 sqm but not exceeding 4 sqm each complete. 80 s & f factory made steel window with side hung shutter including box type hinges with steel handle, steel peg stay, hold fast, complete with glazing bar, dovetailed or welded complete. 81 s & ffactory made steel window with side hung shutter including box type hinges with steel handle, steel peg stay, hold fast complete with ms flat for fixing wire mesh, dovetailed or welded complete . 82 supply only 3 mm thick plain sheet glass / pin headedfigured glass ordinary quality and glazing with oil putty or wooden beads / steel frame in square area n. exc. 0.5 sqm in each pane complete . note : fixing only rate is included in window / door shutter items considered therein 83 supply & fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire stapplescomplete all as specified and directed 84 s & f 125x60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed 85 s&f flush shutters 30mm thick, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed. 86 s & f 35 mm thick of first class hardwood glazed and skeleton shutters, open rebated and prepare to receive glass, gauge, etc., ( with sash bars ) size of members of shutters as specified in ssr part i section 8 clause 8.20 ( a ) supplied and fitted to chowkats complete all as specified and directed. 87 s&f ms flat iron as in hold fast etc and similar work incuding making shape, drilling holes etc, confriming to fe 290 ged e 165 88 m&l for pcc ( 1:3:6 ) type c1 ( using 20mm graded stone aggregate ) as in bed plate for fixing holdfast etc all as specified and directed. 89 s&f aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with beading to wooden frames all as specified and as directed. 90 s&f aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with beading to wooden frames as in repairs all as specified and as directed. 91 s&f aluminium anodised barrel tower bolts of extruded section of length of bolt 200mm all as specified and as directed. 92 supply only butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type b 21 of size 100mm all as specified and as directed. 93 s&f aluminium handles, cast type, anodised of size 100mm all as specified and as directed. 94 s&f 300 mm length aluminium alloy, anodised, sliding door bolts with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed of length of bolt 300mmall as specified and as directed. 95 m&l for preparation of old painted surfaces of wood and wood based materials of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enammel paint. 96 m&l for preparation of old painted steel surfaces and applying one coat of steel painting complete all as specified and directed. 97 m&l for preparation of new steel surfaces and applying two coat of steel paint including primer on steel surfaces complete all as specified and directed. 98 m&l for surface of any discription not otherwise describedover 10 cm width or girth on new untreated surface with two coats of synthetic enammelled painting over one coat pink primer on wooden surface complete all as spd & directed. 99 s&f in repair rubber bead for wooden door 100 dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings complete all as specified and directed 101 s&f pre painted galvalume aluminum zinc coating gi based corrugated steel sheet 0.50mm thick of an colour having tensil strength of 550 mpa as in roof covering to wall fixed with self tapping screws as specified. 102 taking down carefully aluminium battenpoint, wiring for light / fan / socket / bell or power point including. all fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete and making good disturbed surfaces of wall / floor to match with the surroundings of wall / ceiling / floor etc including taking down old light fittings. note : ( i ) contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in mes store yard. ( ii ) quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. ( iii ) decision of ge shall be final and binding in respect of serviceability of fittings / fixture. 103 m & l for point wiring complete with 1.5 sqmm single core pvc insulated frls cable 1100 volts grade with multi stranded copper conductor drawn through new pvc concealed conduit medium grade, isi markedand including provision of 1.5 sqmm pvc insulated copper cable frls as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings: 104 ( a ) one light / fan / bellpoint controlled by one switch single pole one way 105 ( b ) all as per item no 97 here in before butone3 pin 6 amp switch socket out let independent . 106 ( c ) all as per item no 97 here inbefore but one 3 pin 5 amps socket outlet on the same board with other switch complete . 107 all as per item no 97 here in before but using 02 nos. 4.0 sq mm size for main cable and 01 no.4.0 sq mm size as earth conductor for one 16 amp switch socket outlet on independent board. 108 supply and fix switch modular flush 6a single pole one way isi marked 109 supply and fix modular sockets 6 amp 2 in 1 2 / 3 pin combined all as specified and directed. 110 supply and fix switch modular flush type 15 / 16 amp single pole one way 240 volt one module isi marked 111 supply and fix modular sockets 16amp 2 in 1 3 / 5pin combined all as specified and directed. 112 supply and fix ceiling rose surface bakelite 60x25mm three terminal 113 s&f led batten luminaire surface mounted, 4 feet system wattage of 20 watts, system lumen efficiency >90 lumen / watt, 6500kandincluding connectingfrom ceiling rose to fitting completeallas specified and directed. 114 supply and fix in replcementflood light 30 watt 240 volt 50 htz 3000 / 6500k 120 lumen / wattip 65complete all as spd and directed. 115 supply & fix mcb db spn 8 way, double door, ip 43, ik 09, isolated neutral bar and fixed flush to wall and suitable for universal mounting completeall as specified and directed. 116 supply and fix mcb, single pole and neutral, 230 volts, 32 to 40 amp rating, c series fixed in dbs catered here in before. make legrand / hager / siemense 117 supply and fix mcb sp 6 32 amps 240 volts 10 ka 50 hz c curve complete all as specified and directed by engineer in charge 118 supply and fix wall mounted fan 400mm size, 230 volts , 50 hz 1420 rpm with 90 degree oscillation and having speed control by pull cord system complete all as specified and directed. 119 m&l for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 metres deep below ground level ) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia asearth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate no. 3, mes ssr part i 2009 with 15 mm dia medium grade gi pipe as a protection to earthing lead and 20 mm dia medium grade gi pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, rcc pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. notes ( i ) the concrete pit shall be pcc ( 1:3:6 ) type c 1, 40mm thick precast cover slab of rcc with suitable mild steel handle in lieu of cast iron cover shown in electrical plate no 3 of mes ssr part i ( ii ) pcc pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. ( iii ) item includes the cost of 7.5 metre earth lead wire andgi pipe for protection of earth wire. any varriation in quantity shall be adjusted. 120 supply, laying, jointing & testing of underground lt cables xlpe insulated, pvc sheathed, aluminium conductors, multistranded, armoured heavy duty 1100 volt grade cross sectional area 16 sqmm 2 core laid in trenches / ducts / along poles / through pipe under road etc with new aluminium lugs....
36266783 tender for yield test of the bore wells of at af stn b...
36180936 supply of materials and erection for construction of 33 kv s / s chamanganj and malawa and associated 33 kv line under edc ii in distt. prayagraj in deposit scheme on full turnkey basis 2 terminal gantry structure 3 main bus bar complete with structure 4 33 pin insulator with g.i. pin 5 33 kv line isolator 6 33 kv bus isolator 7 structure for above 8 33 kv post insulator 9 structure for above 10 lightning arrester 11 structure for above 12 33 / 11 kv 5 mva t / f 13 90 lbs rail pieces for t / f ( 44.64kg ) / m 14 plinth and foundation of t / f ( 5 mva ) 15 33 kv vcb with single t / f control pannel and ct 200 / 100 / 1a with structure 16 plinth and foundation of vcb 17 11 kv switch gear 18 11 kv switch gear 600 / 300 / 5a 350 mva i / c 19 11 kv switch gear 200 / 100 / 5a 350 mva o / g 20 11 kv 3x185 mm2 xlpecable 21 11 kv 3x120 mm2 xlpecable 22 11 kv 3x185 mm2 xlpe cable jointing kit o / d & i / d 23 m.s.channel 125x65x4000mm for cable stand 24 11 kv 3x120 mm2 xlpe cable jointing kit o / d & i / d 25 24 volt battery & battery charger 26 control cables 27 control cable 4x2.5 mm2 28 control cable 2x2.5 mm2 29 earthing of sub station 30 outdoor equipment ( including earth mat ) 31 indoor equipment ( including earth mat ) 32 barbed wire fencing with gate etc. ( switchyard ) 33 d / p of 11 kv structure on pcc. 8.5 mtr. for feeder 34 outdoor & switchyard & approch road lighting 35 63 kva 11 / 0.4 kv t / f 36 11 kv fuse set with fixing clamp 37 11 kv tpmo switch with fixing clamp 38 cost of accessories for mounting of 63 kva t / f 39 l.t.pvc cable 4x25 mm2 40 painting of s / s structure 41 sundries of stores 42 table 43 chair 44 fire bucket ( 04no. ) with stand 45 hand gloves 46 nomenclature board of switch yard & control room 47 rubber matting 48 sub station name board 49 erection of work as per resspo norms. 50 errection of complete terminal gantry already fabricated and provided by the contractorin switch yard as per drawing.the work includes mounting and fitting of 33kv disc insulator, disc fitting, pin, pin insulator, m.s.channel and all other accessories provided by the department to complete terminal gantry.work also includes construction of gantry plinth of size 1.0x0.45x0.45 cum with cement, coarse sand and ballast in ratio 1:3:6 and plastaring of plinth with cement & sand in ratio 1:4 including digging of pits & backfilling, all concreting material like cement, ballast, sand labour & t&p etc.shall be alsoprovided by the contractor. 51 erection of complete bus bar gantry already fabricated and supplied by the contractorin switch yard as per drawing.work also includes construction of gantry plinth of size 1.0x0.45x0.45 cum with cement, coarse sand and ballast in ratio 1:3:6 and plastaring of plinth with cement & sand in ratio 1:4 including digging of pits & backfilling, all concreting material like cement, ballast, sand labour & t&p etc.shall be provided by the contractor. 52 erection of complete structure for 33 kv isolator in switch yard as per respo drawing. work also includes construction of gantry plinth of size 1.0x0.45x0.45 cum with cement, coarse sand and ballast in ratio 1:3:6 and plastaring of plinth with cement & sand in ratio 1:4 including digging of pits & backfilling, all concreting material like cement, ballast, sand labour & t&p etc.shall be provided by the contractor. 53 erection of complete structure for 33 kv lightening arrestor in switch yard. as per respo drawing. work includes erection of 3 nos.33 kv lightening arrestor, its fitting and mounting with care. grouting of structure with l.c, of 1:3:6 construction of plinth size 0.90x0.45x 0.45 cum. plastering the plinth with cement mortar with cement and sand in ratio 1:4. worksincludes cost of clamp concrete material, labour t&p and cement, which shall be provided by the contractor. 54 erection of complete 33 kv vcb with structure in switchyard and grouting of vcb structures. c.t. structure by cement, sand, brick ballast mortar in ratio 1:3:4. work includes complete fitting of vcb and c.t. on structure carefully with making all connections of control cable for operating the vcb and c.t. only vcb, c.t., battery and battery chargar and their structure shall be provided by the contractor .all other item like cement, concrete material, t&p shall be provided by the contractor. work also includes installation and commissioning of battery and battery charger. 55 installation of 33 kv transformer control pannel in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel.grouting material will be provided by the contractor. 56 erection of complete structure for 33 kv post insulators in switch yard. work includes installation of 3 nos. 33 kv post insulator on each structure complete as per schedule, grouting of structure with ist class brick ballast in the ratio of 1:3:6, plastering in the ratio of 1:3 on plinth size 0.90x0.45x0.45 cum. the work is to be done strictly as per respo drawing. all the material like post insulator cap, cement, concrete material used for above work will be provided by the contractor. 57 construction of complete t / f plinth size 4.46 x 3.46 x 1.0 mtr. above the ground level and 0.5 mtr. deep foundation made as per drawing. top of plinth is to be l.c. work in the ratio of 1:3:6 fitted with 3 mtr. long, 90 lbs, 2nos. rail pieces. cement mortar is to be used in 1:3 ratio. cement, concrete material, bricks used in plinth shall be supplied by the contractor. 6” stone grit is to be laid before foundation start for whole plinth. only rail pieces shall be supplied by contractor . other material shall be provided by the contractor. 58 safe shifting and mounting of 33 / 11 kv 5 mva t / f on the transformer plinth. this work includes dragging loading, shifting, lifting and complete assembling after placing on the plinth.all special and ordinary t&p is to be arranged by the contractor. special care is to be taken to avoid tilting of t / f and loss of transformer oil. any damage in t / f will be chargeable to contractor. 59 laying of earth mat through out 33 kv switchyard area as per respo design and drawing provided by the department. the work includes diggingof trenches 0.75 mtr deep as per drawing. boaring of 33 mm m.s. round electrodes upto 0.5 mtr below ground level. connecting all electrodes with the help of g.i. strips of size 35x6 mm ( approx. 600 kg ) and 40 mm g.i. pipe with proper welding with high quality electrodes m.s. rod, g..i. strip & g.i. pipe shall be provided by the contractor. 60 earthing of each structure erected in the yard with 35x6 mm. g.i. strip in duplicate fully welded at both ends to be connected to the earthmat, necessary g.i. strip shall be provided by the contractor. 61 earthing of 11 kv indoor equipments, switch gears as per respo drawing. with g.i. strip of size 50x6 mm, provided by which will be the contractor. 62 earthing of 33 kv c.t. structure complete as per schedule with 50x6 mm.g.i. strip. all earthing material shall be provided by the contractor. 63 special earthing of lightening arrestor structure with 6 nos. additional 40 mm dia 2.5 mtr. long g.i. pipe electrodes / rod by digging 3 mtr. deep pits and connecting it with l.a. through g.i. strip 35x6 mm welded at both ends. all the material like g.i. pipe, g.i. strip shall be provided by the contractor. 64 special earthing of t / f neutral by boring 2” dia 20 feet long g.i. pipe in the wet earth and connecting it with 35x6 mm. g.i. strip to t / f neutral giving half round turn at the t / f. two separate earthing to be provided to t / f body by connecting it with earth mat by special earthing arrangement for earthing work. material like strip of size 50x6 / 35x6 mm and g.i. pipe 2” dia 2.9 mm thick shall be provided by the contractor used in above work. 65 laying and stringing of acsr dog conductor for busbar between busbar gantry as well as terminal gantry. three phase jumpering from bus to bar l.a, vcb, c.t., post insulator and 33 / 11 kv t / f, terminal gantry, isolator etc. properly with jumpering with p.g. clamp, t. clamp and post insulator clamp, p.g. clamp, t.clamp, a.c.s.r. dog conductorand any other clamp required for jumpering shall be provided by the contractor. 66 painting of all structure and equipment inside the switch yard with two coats of red oxide primer and thereafter two coats of aluminium paint, giving silver white finish, painting is to be done after proper cleaning of the structures. paint, primer, thinner etc. required shall be provided by the contractor himself. 67 providing and erection of fire stand as per drawing for fire bucket withm.s. angle iron 50x50x6 mm with shed of m.s. sheet to cover the bucket and stand properly. all matrial required for this work like m.s. angle. 5 nos fire bucket shall be provided by the contractor. 68 installation of 11 kv vcb in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of 11 kv switchgears rag bolt, mounting ofp.t. on incoming. 69 11 kv in coming 70 11 kv o / g vcb 71 laying of 11 kv 3 x 70 / 120 / 185 / 300 sqmm. xlpe power cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be provided by the contractor. rates may be quoted per rmt 72 construction of cable trenchs for l.t. cable for station t / f in the switchyard as per direction of engineer. trenchs to be 12” wide and 9” deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9” wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. allmaterial will be provided by the contractor. 73 erection of 4no. d / pole 11 mtr long stppole including fixing of top channel on the top the pole and cross brasing, with the help of clamp for 11 kv outgoing feeder of 33 / 11 kv s / s all material required for this work shall be provided by contractor 74 erection of 2no. d / pole 8.5 mtr long pcc pole for substation t / f in switch yard including fixing of top channel cross bracing, s / s base angle, tpmo, fuse set and mounting of 63 kva t / f on d / p and fitting of all accessories as per resspo drawing. all materialrequired for this work shall be provided by contractor 75 cartage of all abovematerials will be done by contractor 76 termination of cable boxes of size 3 x 185 sqmm. for xlpe cable boxes i / d & o / g will be of heat shrink indoor type andoutdoor type cable boxes will be provided by the contractor 77 termination of cable boxes of size 3 x70 / 120 sqmm. for xlpe cable boxes i / d & o / gwill be of heat shrink indoor type andoutdoor type cable boxes will be provided by the contractor 78 laying of 0.4 kv alm. pvc 4x16mm2 l.t. power cable from sub station t / f to l.t. distribution board. approx length of cable 100 mtr. shall be provided by contractor. 79 fabrication and fixing of cable support channel of size 125 x 65 x 6mm. 3.5 mtr. long and grouting with mortar 1:3:6 ratio in switch yard.all the material , shall be provided by the contractor. 80 fabrication and fixing of neutral strip support of t / f made of 65x65x6mm. 3.5 mtr. long and grouting with mortar 1:3:6 ratio in switch yard.all the material such as cement, concrete except strip shall be provided by the contractor. 81 laying of following copper control cable form c.t. t / f to transformer control pannel / protection board. all control cable shall be supplied by the contractor. 82 2x2.5 mm2 83 4x2.5 mm2 84 33 kv line ( appx. 23 km. ) from 132 kv s / s jhunsi to 33 / 11 kv proposed s / s ( chamanganj & malawa ) 85 supply of materials 86 single pcc pole 9.0 m long 87 single stp pole 11 m long 88 v type cross arm 100x50x6 mm, m.s. channel ( 7.9 kg / m, total weight 14.5 kg ) with holding clamp 89 acsr dog conductor ( 23 km ckt ) 90 ms angle 65x65x6 mm, 3.2 mtr long ( 5.8 kg per mtr ) for guarding with clamp 91 top channel 125x65mm 3200 mm ( 10.70 kg. / mtr. ) with clamp 92 33 kv disc insulator polymer 70 kn 93 33 kv disc fitting 70 kn 94 33 kv pin insulator polymer 95 complete stay ( gi stay rod 20x1800 mm, stay wire 7 / 8 swg 10 kg, stay clamp, bolt, nut & washer ) with concrete grouting 96 earthing of pole by ms earthing rod of 20x2500 mm and 6 swg earthing wire etc. 97 gi wire 6 swg & 10 swg for guarding and lacing 98 ms angle iron 65x65x6mm, 4300 mm long bracing with clamp 99 earth wire clamp with bolt & nut 100 e bracket for 33 kv 101 f bracket for 33 kv 102 bolts, nuts & washers 103 danger board with clamp 104 barbed wire 105 concreating of support with cement, sand and bricks ballast ratio 1:4:80.45x0.45x1.5 mtr. deep under the ground 106 railway crossing 107 33 kv 3x300sqmmxlpe cable 108 hdpe pipe 6 dia 109 g.i. pipe 6 dia 110 3x300 sqmm xlpe cable jointing kit 111 m.s. channel 125x65x6x2400 with clamp 112 road crossing 113 33 kv 3x300sqmmxlpe cable 114 hdpe pipe 6 dia 115 g.i. pipe 6 dia 116 3x300 sqmm xlpe cable jointing kit 117 m.s. channel 125x65x6x2400 with clamp 118 33 kv line from 132 kv s / s jhunsi to 33 / 11 kv s / s malawa and chamanganj 119 erection of work as per resspo norms. 120 digging of pits of size 0.45x1.25x 1.50 mtr. forerection of pcc pole 9.00 mtr. long ( s / p, d / p, t / p, f / p ) 121 digging of pits of size 0.45x1.25x 1.85 mtr. forerection of s.t. pole 11 mtr. long for making s / p, d / p, t / p, f / p, xing ht / lt line and canal etc 122 erection of single pcc pole of 9 mtr long. 123 erection of single pole s.t.p. 11 mtr long at x rings. 124 fabrication and erection of double pole of p.c.c. poles 9 mtr long. 125 fabrication and erection of double pole of s.t.poles 11 mtr long. 126 fabrication and erection of tri pole structure of p.c.c. poles 9 mtr. 127 fabrication and erection of tri pole structure of s.t. poles 11 mtr. 128 fabrication and erection of four pole structure of p.c.c. poles 9 mtr. 129 fabrication and erection of four pole structure of s.t. poles 11 mtr. 130 mounting and fitting of v type cross arm, 33 kv pin, pin insulator, earth clamp complete in all respect as per drawing of respo on single pcc pole 9 mtr long and single s.t. pole 11 mtr long. cross arm, pin, pin insutator, cross arm cramp, danger board with clamp shall be provided by contactor. 131 fabrication, mounting and fitting of top channel, bracing made of m.s. angle, earth clamp, 33 kv pin & pin insulators, disc insulator anddisc fitting on p.c.c. ands.t.p. double pole.top channel bracing m.s. angle, 33 kv pin and pin insulator. disc insulator and disc fitting , earth clamp, stay clamp, top channel clamp, bracing clamp, danger board etc. shall be provided by contractor. 132 fabrication, mounting and fitting of top channel, bracing made by m.s. angle, earth clamp, danger board, pin and pin insulators, disc and disc fitting on tri pole structures. pcc 9 mtr. / stp 11 mtr. top channel bracing, pin and pin insulator, disc and disc fitting , stay clamp, top channel clamp, bracing clamp, earth clamps and danger board etc. shall be provided by the contractor. 133 fabrication, mounting and fitting of top channel, bracing made by m.s. angle, earth clamp, danger board, pin and pin insulators, disc and disc fitting on four pole structures. pcc 9 mtr. / stp 11 mtr. top channel bracing, pin and pin insulator, disc and disc fitting stay clamp, top channel clamp, bracing clamp, earth clamps and danger board etc. shall be provided by the contractor. 134 grouting of single pcc pole 9 mtr long with cement, sand and brick bllast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res 6.cement, sand, brick, ballast shall be provided by the contractor. ( s / p, d / p, t / p, f / p ) 135 grouting of single s.t. support 11 mtr longwith cement, sand and brick ballast in ratio 1:4:8 size 0.45x 0.45x1.85 mtrdeepunderthe ground and 0.45x 0.45x 0.45 mtr above the ground including plastering and polishing with neat cement ( it includes the grouting of st poles of single pole support, double poles, tripole and four pole structures. ) cement, sand, brick, ballast shall be provided by the contractor. 136 digging of pits of size 0.60x 0.60x1.2 mtr and grouting the stay rod anchor plates 0.45x 0.45x 0.45 mtr with cement, jamuna sand and brick ballast ratio 1:4:8 as per drawing no. res 16. cement, sand, brick, ballast shall be provided by the contractor. 137 complete fitting of stay rod and fastening stay wire including fitting of stay clamp, turn buckle, and making ring of stay wire on both ends in seven strands9” to 12” long. stay clamp, turn buckle shall be provided by thecontractor. 138 earthing of single pcc / st pole by digging 1.00 mtr deep pit and driving the electrodes of ms earth rod and connecting all the metallic parts of poles with earthing rod by g.i. wire and filling pits with soil after completion of earthing.earth wire / g.i. wire m.s.rod shall be provided by the contractor. 139 work of road, canals, telephones and h.t. line crossing by providing guarding angles / channels on supports and fabrication and fiting of guarding net as per drawing no. 48 with g.i. wire no. 8 / 10 swg, guarding angle except guarding angle andg.i. wire all other materials provided by the contractor. 140 laying of a.c.s.r. dog conductor with thehelpof aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of a.c.s.r. dog conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support.all material required for above work shall be provided by contractor such as jointing sleeve binding wire, armour rod etc. 141 railway crossing 142 road crossing 143 loading carriage and unloading of following line materials 144 p.c.c. 9 mtr. long. 145 stp 11 mtr. long. 146 acsr dog conductor. 147 33 kv 3x300 sqmm xlpe cable 148 hdpe pipe 6 dia 149 other items as per requirement for construction of line ( disc, disc fitting, x arm. pin, pin insulator, stay rod, earth rod, m.s. rod, g.i wire etc. 150 trimming of tree branch big / small branch which is laying in alignment of33 kv line from 220 / 132kv s / s jhunsito tapping point 33 / 11 kv linemalawa and chamanganjdist. prayagraj. 151 big branch 152 small branch 153 jumpring of33 kv line on 33 kv bay using p.g. clamp dog to dog& dog conductor & binding of jumper and other accessories on terminal gantry at 33 / 11 kv s / s malawa and chamanganjdisst. prayagraj.binding wire & p.g. clamp, aluminiumlug etc. provided by contractor. 154 construction of control room building, boundary wall , road & other misc. civilwork at 33 / 11 kv substation chamanganj & malawa 155 clearing jungle including uprooting of rank vegetations, grass, bush, wood, trees and saplings of girth upto 30cm measured at a height of 1.0m above ground level and removal of rubbish upto a distance of 50m outside the periphery of uppcl area cleared. ( csi no. 4.08 ) 156 excavation in foundation in ordinary soil ( loam clay or sand ) including lift upto 1.5m and lead upto 30m and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of the foundation work. ( csi no. 4.01 ) 157 concrete with 4cm gauge i class brickballast, coarse sand and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. ( csi no.5.01 ) 158 concrete with 4cm gaugestone ballast, coarse sand ( f.m. 1.8 to 2.5 ) & cement in proportion of 12:6:1 in foundations &under floors including supply of all materials, labour and tools and plants etc. required for proper completion. ( csi no. 5.02 ) 159 tmt / tor steel in plain work such as reinforced concrete orreinforced brick work ( when not included in an over all rates ) wrought to required shape as necessary including bending forproper completion of the work and including supply of steel its wastage, bend, hooks and authorized overlapping shall be measured. ( steel shall be arranged by the contractor ) ( csi no. 9.03 ) 160 rcc work with cement approved coarse sand ( f.m. 1.8 to 2.5 ) and2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from dalla, jhansi or other quarries and approved coarse sand in proportion1:1.5:3 in raft foundation and footings , excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and t&p. ( csi no. 5.27 ) 161 rcc work with cement approved coarse sand ( f.m. 1.8 to 2.5 ) and2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from dalla, jhansi or other quarries and approved coarse sandin proportion 1:1.5:3in rcc t beam slab and column , excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and t&p . ( csi no. 5.29 ) 162 first class brick ( class 150 ) work in 1:6 cement and coarse sand ( f.m.1.8 to 2.5 ) mortar in foundation and plinth including supply of allmaterials, labour & t&p etc. required for proper completion of work. ( csi no. 6.01 ) 163 first class brick ( class 150 ) work in 1:4 cement and coarse sand ( f.m.1.8 to 2.5 ) mortar in superstructure for walls of 1 / 2 brick ( 115 mm ) thickness including supply of allmaterials, labour& t&p etc. required for proper completion of work ( csi no. 6.03+6.07+6.09 ) 164 earth filling under floors and / or sub station area including cost of earth when obtained from with in 8 kmoutside uppcl area including its roylty and carriage including watering, ramming in 20 cm layers and dressing of earth etc. all complete. ( csi no. 4.10 ) 165 local sand filling in plinth including supply of necessary quantity oflocal sand from outside the uppcl premises including watering, dressing etc. rate to include cost of all materials, labour and t&p etc. required for proper completion of work. ( csi no. 4.05 ) 166 pre construction anti termite treatment, by creating a barrier under and around the columns pits, foundation trenches, under floors, junctions of walls &floors, around the external perimetre of building, expansion joints, surrounding of pipes and coduits etc. ( plinth area of the building at ground floor only shall be measured as per i.s. 6313 ( part ii 1981 ) ) with aldrine emulsifiable 0.2% concentration or any other approved material such as heptachlore or chlordance will be used. the consumption of emulsion shall be ( i ) foundation and masonary @ 5 ltrs / sqm, ( ii ) back fills in immediate contact of foundation@ 7.5 ltrs. / sqm, ( iii ) top surface of plinth filling @ 5 ltrs / sqm, ( iv ) junction of walls & floors @ 7.5 ltrs / sqm, ( v ) soil along external perimetre of building @ 7.5 ltrs / sqm ( vi ) under apron of the building @ 5 ltrs. / sqm. the rates includes cost of all materials, labour, equipments, t&p complete. ( csi no. 17.01 ) 167 cement concrete with 2cm gauge approved hard stone ballast, coarse sand ( f.m. 1.8 to 2.5 ) and cement in proportion of 1:1.5:3. including supply of all materials, labour, side shuttering if required and t&p etc. required for proper completion of work ( csi no. 5.21 ) 168 mild steel or iron work in heavy sizes such as trusses built upgates, door frames, record, racks roof work gates etc. wrought torequired form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost of all materials supplied by contractor. ( csi no. 9.01 ) 169 first class brick ( class 150 ) work in 1:6 cement and coarse sand ( f.m.1.8 to 2.5 ) mortar in super structure a including supply of allmaterials, labour & t&p etc. required for proper completion of work. ( csi no. 6.01+6.07+6.08 ) 170 providing and fixing steel glazed window and ventilators ofstandard rolled mann or mahavir steel sections conforming to is7452 1974 as per drawing joints metered & welded with 100x14x3.15 mm holdfast embedded in cement concrete block 15x10x10 cm. size of 1:3:6 proportion i.e. first part of cement 3 part of approved coarse sand & 6 part of graded stone ( aggregated 20mm. nominal size ) s / f of glass panes of plain pin headed 4mm. thick nuts glazing clips and special putty of approved make complete and including a cost of red oxide paint. the fabrication should conform to i.s.1038 1975. ( aluminum beading with rubber packing included ) . ( csi no. 9.17 ) 171 rcc work with cement approved coarse sand ( f.m. 1.8 to 2.5 ) and2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from dalla, jhansi or other quarries and approved coarse sand in proportion 1:1.5:3in lintels of doors and windows, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and t&p. ( csi no. 5.23 ) 172 cement concrete with 2cm gauge approved hard stone ballast, coarse sand ( f.m. 1.8 to 2.5 ) and cement in proportion of 4:2:1including supply of all materials, labour, side shuttering ifrequired and t&p etc. required for proper completion of work. ( csi no. 5.06 ) 173 rcc work with cement approved coarse sand ( f.m. 1.8 to 2.5 ) and2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from dalla, jhansi or other quarries and approved coarse sand in proportion 1:1.5:3inslab, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and t&p. ( csi no. 5.24 ) 174 s / f hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16swg ms sheet incorporating 10mm dia ms round bar duly bend for supporting fan hanger, duly painted with red oxide and screw arrangement and with wiring conduit laid in the rcc roof before concreting alongwith supply of all material labour t&p etc. required for proper completion of work as per direction of eic. ( nsi ) 175 12 mm thick plaster with cement mortar consisting of one part of cement & three part of coarse sand ( 1:3 ) , minimum thickness not to be less then 10 mm including supply of all materiallabour and t&p etc for proper completion of work. ( csi no. 11.06 ) 176 6 mm. thick plaster with 1:3 cement & coarse sand includinglabour, materials & t&p etc. required for proper completion ofthe work. ( csi no. 11.17 ) 177 3 mm thick floating coat of neat cement finish including supply of all materials, labour and t&p etc. required for proper completion of the work. ( cement consumtion 0.044 bag / sq.m. ) ( csi no. 11.20 ) 178 s / mixing approved water proofing compound ( cico, dr fixit etc ) in cementmortar in plaster or concrete work in the proportion as recommended by the manufacturer. ( csi no. 11.15 ) 179 12 mm thick plaster with cement mortar consisting of one part of cement & four part of coarse sand ( 1:4 ) , minimum thickness not to be less then 10 mm including supply of all material, labour and t&p etc for proper completion of work. ( csi no. 11.07 ) 180 12 mm thick plaster with cement mortar consisting of one part of cement & six part of coarse sand ( 1:6 ) , minimum thickness not to be less then 10 mm including supply of all material, labour and t&p etc for proper completion of work. ( csi no. 11.09 ) 181 add for extra labour and materials for plaster over rough face ofone brick thick wall. ( csi no. 11.12 ) 182 providing ( 12x15 ) mm section groove in plasterincluding all material, labour andt&p etc. required for proper completion of the work. ( csi no. 11.16 ) 183 making drip course ( 25x12 ) mm in 1:2 cement and course sandincluding supply of all materials, labour and t&p etc requiredfor proper completion of work. ( csi no. 11.19 ) 184 providing m.s. frames work, rack etc for r.c.c. trench covers and edging with m.s. angles and m.s reinforcement including cutting, bending and welding as per approved drawing. therate is including cost of all labour, materials etc. as required for proper completion of the work. ( csi no. 9.20 ) 185 fixing of cable trench edging in proper position and alignment including cost of all labour, material and t&petc. required for proper completion of the work ( labour rate only ) . ( csi no. 9.30 ) 186 concreting of 40 mm thick rcc trench covers in mild steel framework with rcc 1:1.5:3 in cement, chopan coarse sand ( f.m. 1.8 to 2.5 ) and 2cm gaugegraded hard stone ballast with 3mm thick floating coat of neatcement finish on top of cover complete with all labour, materials and placing the same in proper position at required location of cable trench within the substation area. ( csi no. 5.18 ) 187 4.0 cm thick 1:2:4 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and t&p etc, required for proper completion of the work. without base cc ( csi no. 12.04 ) 188 providing and fixing glass strips of 3.15 mm thickness & 40mm depth in jointsof floor and skirting at the time of laying floors, flush withfloor level including supply of all materials, labour& t&p etc. completion required for proper completion of work. ( csi no. 12.14 ) 189 supply of 80 mm thick i shaped mechanically compressed inter locking cement concrete paver block manufactured by high pressure & controlled vibration machine having plan dimension 200x ( 160+120 mm ) with minimum 5 mm thick toping of o.p.cement mixed with 25% marble powder. the compressive strength of concrete pavers blocks shall not be less than 30 mpa & 4.5 kg / no. including cost of all material, labour, t&p etc. required for proper completion of work as directed by engineer in charge but excluding g.s.t. which shall be paid extra as per rules. ( csi no.12.23 ) 190 straight over burnt bricks on edge floor laid dry, joints sand filled, including preparation of base to proper slope and its rammingincluding supply of all material labour & t&p etc. required forproper completion of the work. ( csi no. 12.09 ) 191 supply and fixing galvanised mosquito proof jali ( 16x24 gauge ) withm.s. flat of 20 x 3 mm. size, on both sides screwed or welded to windowor door frame. ( csi no. 9.18 ) 192 providing and laying floor of 8 mm thick vitrifiedtiles in flooring or skirting of approved brand ( bell, johnson or equi. make ) size of 600x600 mmof approved shade, colour and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cementmixed with pigment to match the shade of tile including cost of all material, labour and t&p required for proper completion of the work. ( csi no. 12.18 ) 193 supply and laying 8 mm thickglazed floor tiles of somany, johnson or equivalent make, of size 300x300 mm, laid with1:3 cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supplyof all materials, labour and t&p etc. completion required for proper completion of the work. ( csi no. 12.11 ) 194 supply and laying 6 mm thickglazed tiles of size 300x450 mm in skirting / dado laid with1:3 cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supplyof all materials, labour and t&p etc. completion required for proper completion of the work. ( csi 12.12 ) 195 supply and filling brick bat in soak pit including all labour, material and t&p etc complete. ( for 01 soak pit ) ( csi no. 6.23 ) 196 first class brick ( class 150 ) laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0m depthincluding cutting moulding bricks as required including cost ofall materials labour and t&p complete. ( csi no. 6.16 ) 197 providing and fixing 15 mm dia b class jindal, jtc, isi marked g.i. pipes complete with special such as bend, tee, socket, cross, clamp etc earth work including filling the trenches etc required for proper completion of the work. the rate also includes concealed gi fitting where required, cutting and making good the walls etc and all materials, labour and t&p complete. ( csi no. 26.01a ) 198 providing and fixing 20 mm dia b class jindal, jtc, isi marked g.i. pipes complete with special such as bend, tee, socket, cross, clamp etc earth work including filling the trenches etc required for proper completion of the work. the rate also includes concealed gi fitting where required, cutting and making good the walls etc and all materials, labour and t&p complete. ( csi no. 26.01b ) 199 providing and fixing 25 mm dia jindal, jtc, isi marked g.i. pipes complete with special such as bend, tee, socket, cross, clamp etc earth work including filling the trenches etc required for proper completion of the work. the rate also includes external gi fitting where required, cutting and making good the walls etc and all materials, labour and t&p complete. ( csi no. 26.02c ) 200 providing and fixing 32 mm dia jindal, jtc, isi marked g.i. pipes complete with special such as bend, tee, socket, cross, clamp etc earth work including filling the trenches etc required for proper completion of the work. the rate also includes external gi fitting where required, cutting and making good the walls etc and all materials, labour and t&p complete. ( csi no. 26.02d ) 201 providing & fixing half turn 32mm dia gate valve, isi mark heavy quality including supply of all materials, labour and t&p required for proper completion of work. ( csi no. 26.05d ) 202 providing & fixing half turn 25mm dia gate valve, isi mark heavy quality including supply of all materials, labour and t&p required for proper completion of work. ( csi no. 26.05c ) 203 p / fbrass angle valve 15 mm dia ( 400 gsm ) isi mark heavy quality including supply of all materials, labour and t&p required for proper completion of work. ( csi no. 26.16i ) 204 providing and fixing cp brass bib cock15 mm dia. heavy quality ( 400gm ) ( l & k and equi. ) fittings, isi mark heavy quality including supply of all materials, labour and t&p required for proper completion of work. ( csi no. 26.16a ) 205 providing and fixing cp brass piller cock heavy quality ( l&k or equi. ) fittings, isi mark heavy quality including supply of all materials, labour and t&p required for proper completion of work. ( csi no. 26.16j ) 206 providing and fixing first quality white glazed orissa pattern w.c.pan hindustan, cera make. size 580 mm. ( hindustan, cera make ) with out p trapincluding supply of all materials, labour and t&p etc.complete. ( csi no. 27.01 ) 207 providing and fixing pvc connection pipe, 450x15 with 2 brass units isi mark heavy quality including supply of all materials, labour and t&p required for proper completion of work. ( csi no. 26.09b ) 208 providing and fixing in position 32 mm. dia p.v.c.waste pipe for wash basin. including supply of all materials, labour and t&p etc.required for proper completion of the work. ( csi no. 27.14 ) 209 providing and fixing 100 mm dia pvc p or s trap including cement concrete and all materials, labour cartage t&p etc.required for proper completion of the work. ( for w.c. ) ( csi no. 27.24 ) 210 providing and fixing 10 littres low level pvc flushing cistern, complete with all fittings including supply of all materials, labour and t&p etc. required for proper completion of the work. ( csi no. 27.12 ) 211 providing and fixing in position 32 mm. dia p.v.c. flush pipe. for w.c. with unions, bends etc. including supply of all materials, labour and t&p etc.required for proper completion of the work. ( csi no. 27.13 ) 212 supply and fixing 100 mm dia pvc nahani trap india make of heavy approved quality complete with grating, includingsupply of all materials, labour and t&p etc. required for proper completion of the work. ( csi no. 27.21b ) 213 providing and fixing 550x400 mm wash hand basin of white glazed earthern ware first quality i.s.i. marked ( hindustan, neycer / cera make ) including supply of all materials, labour and t&p etc. required for proper completion of the work. ( csi no. 27.08 ) 214 supply and fixing of syntex or equivalent make water storage tank including all materials, labours, t&p etc required for proper completioon of work. ( csi no. 26.12 ) 215 providing and fixing of 110 mm dia pvc pipe 6 kg / sq.cm forwith special such as tee, bend, socket, elbow etc including supply of all labour, material, t & p etc complete required for proper completion of work. ( csi no. 26.17 ) 216 providing and fixing 600 mm x 450 mm beveled edge mirror of atul, kiran makeglass with indian polish 6.50 mm thick complete with back of 600 mm x 450 mm x 6 mm hard board sheet fixed to wooden cieats with c.p. brass screws and washers including supply of all materials, labour and t&p etc.required for proper completion of the work. ( csi no. 27.15 ) 217 applying birla or equivalent putty on new interior or exterior surface over one coat of water based cement primer of ici or equivalent brand for smoothening and levelling of the surface as per requirement and direction of engineer i / c including cost of all material, labour, t & p etc required for proper completion of work. ( csi no. 13.20 ) 218 painting two coat with acrylic emulsion paint of berger / asian / ici or equivalent paint ( paint and water in the ratio 1:1 by volume ) over prepared and primed surface of cement concrete, cement plaster and bricks including all labour, material and t&p etc required for proper completion of the work, ( preparation of base with birla putty etc. and a coating of primer shall be paid extra ) . ( csi no. 13.25+13.26 ) 219 painting two coat with apex or equivalent brand weather coat paint on new wall surfaces ( well prepared with birla putty and one coat of primer ici or equivalent which shall be paid separately ) including through washing with water including cost of all materials, labour, t&p required for proper completion of work. ( csi no. 13.22+13.23 ) 220 painting or varnishing new iron works or new wood work with one coat of ready mixed priming paint and two coats of approved superior quality ready mixed paint luxol or equivalent brand or varnish including supply of all materials, labour& t&p etc. required for proper completion of the work ( c.s.i. no. 13.01+13.02 ) 221 grouting of vertical or inclined post of pale / chain / security fencing in truelevel, alignment and in plumb or inclination as required, including cost of all labour, materials and t&p required forproper completion of work. ( post and concrete for grouting shall be measured separately ) ( csi no. 9.28 ) 222 p / f concertina coilfencing with required dia. 600 mm upto 3 m height of wall between existing angle iron ‘y’ shaped placed 2.4 m or 3.0 m apart and with 6 horizontal r.b.t. stud tied with g.i. staples and g.i. clips to retain horizontal including necessary golts or g.i. barbed wire tied to angle iron all complete ( no. of rounds will be 7 to 8 in one meter length ) as per direction of engineer i / c with reinforced barbed tape ( r.b.t. ) / spring core ( 2.5mm thick ) wire of high tensile strength of 165 kg / sqmm with tape ( 0.52 mm thick ) of supreme make or equivalent and weight 43.478 gm / meter ( cost of ms angle, c.c. blocks shall be paid separately ) . ( csi no. 9.37 ) 223 wiring point for lightwith 1.5 sq. mm frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit pipe concealed in the wall with 1sqmm frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduit piano type switch and ceiling rose / angle / batten holder on 3mm thick phenolic laminated backelite sheet etc, complete in all respects, as directed, including maching colour wash. ( nsi ) 224 wiring point for fan / fresh air fan ( light duty exhaust fan ) with 1.5 sq. mm frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit pipe concealed in the wall with 1sqmm frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduit piano type switch and ceiling rose / angle / batten holder on 3mm thick phenolic laminated backelite sheet etc, complete in all respects, as directed, including maching colour wash. ( nsi ) 225 wiring point for exhaust fan with 1.5 sq. mm frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit pipe concealed in the wall with 1 sqmm frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduit, 15a piano type switch and ceiling roseon 3mm thick phenolic laminated backelite sheet etc, complete in all respects, as directed, including maching colour wash. ( nsi ) 226 wiring point for plug with 1.5 sq. mm frlsh pvc insulated multistrand single core copper conductor cable in pvc conduit pipe concealed in the wall with 1 sqmm frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduit, piano type switch and ceiling rose / angle / batten holder on 3mm thick phenolic laminated backelite sheet etc, complete in all respects, as directed, including maching colour wash. ( nsi ) 227 s / f of switch box made of 16swg ( 1.5mm ) thick ms sheet of 100x100x65mm size duly painted with red oxide primer and flush with wall including cutting of brickwork fixing it to level with cement sand mortar including matching color wash with all materials labour and t&p required for proper completion of work as directed at site by the eic. ( nsi ) 228 s / f of switch box made of 16swg ( 1.5mm ) thick ms sheet of 150x150x65mm size duly painted with red oxide primer and flush with wall including cutting of brickwork fixing it to level with cement sand mortar including matching color wash with all materials labour and t&p required for proper completion of work as directed at site by the eic. ( nsi ) 229 s / f of switch box made of 16swg ( 1.5mm ) thick ms sheet of 175x100x65mm size duly painted with red oxide primer and flush with wall including cutting of brickwork fixing it to level with cement sand mortar including matching color wash with all materials labour and t&p required for proper completion of work as directed at site by the eic. ( nsi ) 230 s / f of switch box made of 16swg ( 1.5mm ) thick ms sheet of 250x250x65mm size duly painted with red oxide primer and flush with wall including cutting of brickwork fixing it to level with cement sand mortar including matching color wash with all materials labour and t&p required for proper completion of work as directed at site by the eic. ( nsi ) 231 supply and fixing of led tube light of make syska, bajaj phillips or equivalent make of 22watt on surface complete including all material and t&p etc in all respect as per direction of eic ( nsi ) 232 supply and fixing of led bulb of make syska, bajaj phillips or equivalent make of 12watt on surface complete in all respect as per direction of eic ( nsi ) 233 supply and fixing of led flood light of make syska, bajaj phillips or equivalent make of 100watt on surface complete in all respect as per direction of eic ( nsi ) 234 supply and wiring of sub main with two nos 2.5 sq.mm f.r.p.v.cinsulated 1100v grade multi strand single core copper conductor, cable in 20mm dia heavyduty ( 2mm thick ) pvc conduit concealed in wall with one number 1.5 sq.mm multi strand copper conductor, cable as earth continuity wire drawn in a conduit . ( nsi ) 235 supply and wiring of sub main with two nos 4 sq.mm f.r.p.v.cinsulated 1100v grade multi strand single core copper conductor, cable in 20mm dia heavyduty ( 2mm thick ) pvc conduit concealed in wall with one number 2.5 sq.mm multi strand copper conductor, cable as earth continuity wire drawn in a conduit . ( nsi ) 236 supply and fixing of 1200mm sweep ceiling fan of make usha / havells or its equivalent makeincluding supply of all material, labour, t&p etc. required for proper completion of work as per direction of eic. ( nsi ) 237 supplying and fixing 63a dp isolator of approved make ( havells, crompton, anchor or equivalent ) complete including all material and t&p etc in all respect as per direction of eic ( nsi ) 238 supply and fixing of 6 amps to 32 amps mcb 10ka havells or equivalent make including all materials, labour and t&p requiered for proper completion of work as per direction of eic ( nsi ) 239 supply and fixing of power plug with 15amps. 250v. flush type switch and 5pin 15a 250v. flush type universal socket in suitable m.s.box of 175x100x50mm size with phenolic laminated bakelite sheet cover 3mm. thick fixed with brass machinesscrews and cup washer ( nsi ) 240 supply and fixing of surface / flush mounting 12 ways spn distribution board with additional metal door without mcb complete in all respect as directed by eic ( nsi ) 241 supply and fixing of power plug with 20amps. 250v. flush type modular switch and 5pin 20a 250v. flush type universal modular socket switch on concealed ms box including supply of all material, labour, t&p etc. required for proper completion of work as per direction of eic ( nsi ) 242 supply and fixing of electronic fan regulator 120 280v isi marked on the existing switch board incl. making connection, required mmaterial, labour t&p etc. for completion of the work to the satisfaction of eic . ( nsi ) 243 supply and burying of safe earthing electrode of t90 ( hot dip galvanised ) length upto 2m, outer pipre 50mm , inner pipe 25mm, terminal dia 12mm, outer gi pipe of 16swg and inner gi pipe of 12 swg with hot dip galvanisation upto 100 micron field with crystalline condutive mixture having anti corossive and condutive property with 50kg activated soil ( bfc ) capable of reducing the soil resistivity wit good mixture of retaining capacity alongwith 30cm square ci frame with hinged cover and masonry housing ( from electrode terminal to switch board, cost of 25x3mm gi strip will be extra ) including all labour , material and t&p required for proper completion of work as per direction of eic. nsi 244 supply and installation of india mark hand pump ii including 150 mm dia , 70m deep boring up to second starta including supply and lowering 110mm to 63mm dia pvc pipe ( 24m 110mm & 44m, 63mm, 6 kg / sq.m ) with required strainer, reducer joining 90 mm dia long cylinder, 32mm dia gi pipe 3mlong including supply anf filling of course sand of approved quality ( approx. .15 cum ) including developing the bore well to achive clear and sand free water for continous 60 min. including cost of all material, labour and t&p and its cartage for installation of hand pump complete as per drawing including construction of 1.85 m dia chabutara with excavation of earth and laying 25mm c.c. floor 1:2:4 with cement, c.sand and 20mm stone ballast with water proofing compound over 100 mm thick c.c. 1:6:12 with cement, c.sand and 40 mm brick ballast and making side edge 115mm thick and 300 mm deep with brick work 1:4 and plaster the same with 1:4 mix with neat cement finish also including 115 mm wide drain in 1:4 brick work & plaster all around the periphery of plateform complete including supply of all materials, labour and t&p etc required for proper completion of work. rate as per se, 7th mandal, up jal nigam, gorakhpur letter no 1045 dt 16.02.15 ( csi no.28.10 ) 245 supply and fixing of 40.00 mm dia g.i. ( b class ) column pipes jtc / jindal make with column coupling socket as required for proper completion of workincluding all labour material & t&p. ( csi no. 19.22c ) 246 supply and fixing 40 mm dia support clamps for column pipesmade out of ms flats, pairs of bolt nuts etc complete with all material, labour, t&p. ( csi no. 19.24d ) 247 supply & installation of 1.5 hp outlet 40mm dia. or more, head 71 / 36, discharge 2000 / 6000 lphsubmersible pump of k.s.b / calama. or eqt. make including cost of labour, t&p and material required for completion of work. ( csi no. 19.32b ) 248 supply & installation of electrical control panel for 1.5 / 2 h.p pump set single phase of l&t / havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. ( csi no. 19.31b ) 249 supply & fixing of steel wire rope forsubmersible pump including cost of labour, t&p and material required for completion of work. ( csi no. 19.34 ) 250 supply and fixing of2.5 mm2 for pumpabove 1 hp and up to 3 hp. submersible cable havelsor equivalent make, for submersible pump complete in all respect. ( csi no. 19.33b ) ...
36091412 construction of new bore well at firozabad city gate station...
36086386 tender for repairing 01 no bore well at gc crpf rampur u.p....
35866581 special repair for replacement of old vintage bore well no. 3 in domestic area at af station sarsawa under ge ( af ) sarsawa...
35680769 repair / maintenance of existing bore well with rewinding of sub pump set of cod inside area uder ge ( i ) kanpur repair / maint of existing borewell with rewinding of sub pump set of cod inside area uder ge ( i ) kanpur...
35620667 repairing 01 nos bore well at gc crpf rampur...
35583986 tender for irrigation management ( boring, pipeline, popup, drip line etc. ) work from shaheed path ( kanpur road ) from 0.00 to 6.00 km ( lumsum ) 1 drip material of irrigation 2 disc filter 2 3 by pass valve 2 4 air release valve 1 5 pressure guage 2 ( gil. filled ) 6 non return valve 2 7 pvc pipe 75 mm ( 4kg / cm2 ) 8 pvc pipe 63 mm ( 4kg / cm2 ) 9 plain lateral 16 mm 10 emmiting pipe 16 mm cl ii 1 to 4 lph 11 control valve 63 mm 12 flush valve 63 mm 13 valve box 10x10 14 pop up sprinkler complete set ( 5 10 mt radius ) 15 installation charges. @ 5.00% on 3590293.67 16 trenching backfilling & boring 17 trenching and back filling for drip 18 filtration station 19 boring 20 boaring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in is : 2800 part i, including collecting sample from different starta, preparing and submitting equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, up to 90 meter depth below ground level. all type of soil ( dar 16 23.1.1 based ) sanction rate 21 0 15 m bgl 22 15 30 m bgl 23 30 65 m bgl 24 supply, assembling, lowering and fixing in vertical position in bore wellpvcpipes required dia including required hire & labour labour charges, fittings & accessories etc. all complete for all depths as per direction of engineer in charge.110 mm nominal size dia pvc pipe 10 kg / sqcm dar 16 23.3.1 25 supply, assembling, lowering and fixing in vertical position in bore well pvc pipes stainer pipes including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of engineer in charge. 110 mm nominal size dia pvc pipe 10 kg / sqcm dar 16 23.4.1 26 supply & fixing end cap 110 mm dia. sanctioned rate 27 supply, assembling, lowering and fixing in vertical position in bore well cpvc screeen pipesincluding required hire & labour labour charges, fittings & accessories etc. all complete for all depths as per direction of engineer in charge. 40 mm nominal size dia. sanctioned rate 28 providing & fixing m.s. clamp of required dia to the top of casing / housing pipe of tube well as per is 2800 part 1 including necessary bolts & nuts of required size complete. sanctioned rate 29 gravel packing in bore well including providing 5 10 mm stone grit in required grading & size as per actual requirements, all complete as per direction of engineer in charge.sanctioned rate. 30 supply / erection of 40 mm dia gi elbow. sanctioned rate. 31 supply / erection of 3 hp make crompton or equalent submersible pump. sanctioned rate attached....
35537692 tender for maintenance and repair and work and other misc. civil work at 33 / 11 k.v. s / s , jangipur ( old ) , distt ghazipur 1 dismantling brick work or stone work in lime or cement mortar andincluding stacking of materials as directed by theengineer in charge within a distance of 60 metres. 2 dismantling of existing damaged mud faska over the roof. cleaning the surface with wire brush, removal and disposal of rubbish at adistace 100 meters also including the cost of cleaning and stacking of usable materials etc., including all labour, material required for proper completion of work. 3 providing of dr. fixit 301 pidicrete urp & mixing it properlywith cement in the proportion of 1:1.5 apply two coat to the prepared surface including cost of labour, material t&p etc. as required for proper completion of work as directed by e / i. 4 tmt / tor steel in plain work such as reinforced concrete orreinforced brick work ( when not included in an over all rates ) wrought to required shape as necessary including bending forproper completion of the work and including supply of steel its wastage, bend, hooks and authorized overlapping shall be measured. ( steel shall be arranged by the contractor ) . 5 rcc work with cement approved coarse sand ( f.m. 1.8 to 2.5 ) and2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from dalla, jhansi or other quarries and approved coarse sand in proportion 1:1.5:3inslab, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and t&p. 6 providing and fixing of dr. fixit lw+ in rcc / cc / plaster etc. 200ml per bag of cement as directed by e / i including supply of all material, labour and t&p etc. required for proper completion of work as directed by e / i. 7 12 mm thick plaster with cement mortar consisting of one part of cement & three part of coarse sand ( 1:3 ) , minimum thickness not to be less then 10 mm including supply of all materiallabour and t&p etc for proper completion of work. 8 3 mm thick floating coat of neat cement finish including supply of all materials, labour and t&p etc. required for proper completion of the work. ( cement consumtion 0.044 bag / sq.m. ) 9 first class brick ( class 150 ) work in 1:6 cement and coarse sand ( f.m.1.8 to 2.5 ) mortar in super structure including necessary cutting and moulding of bricks as required and also including honeycomb brick work. 10 as in item 09 above but for walls of 1 / 2 brick ( 115 mm ) thickness, addfor extra labour in super structure including necessary cutting and moulding of bricks as required and also including honeycomb brick work. 11 providing gola 75x75mm in c.c. 1:2:4 with coarse sand and 10mm down grit including finishing with cement mortal 1:3 as per standard design. 12 dismantling existing plaster including disposal of refuse asdirected by the engineer i / c within a distance of 60 m. 13 dismantling cement concrete or brick or granolithic floorsincluding base concrete and including stacking of dismantledmaterials as directed by the engineer in charge within a distanceof 60 metres. 14 dismantling doors or window leaves including stacking ofmaterials as directed by the engineer i / c within a dist. 60 m. 15 dismantaling doors and windowschowkhatsincluding stacking of materials as directed by engg in charge within a distance of 60 meters. 16 dismantling reinforced cement concrete or reinforced brick work, including stacking of dismantled materials as directed by theengineer incharge within a distance of 60 metres. 17 scrapping old white or colour wash or distemper including disposal of refuseas directed by the engineer i / c within a distance of 60 m. 18 rcc work with cement approved coarse sand ( f.m. 1.8 to 2.5 ) and2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from dalla, jhansi or other quarries and approved coarse sand in proportion 1:1.5:3in lintels of doors and windows, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and t&p. 19 mild steel or iron work in heavy sizes such as trusses built upgates, door frames, record, racks roof work gates etc. wrought torequired form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost of all materials supplied by contractor. 20 cement concrete with 2cm gauge approved hard stone ballast, coarse sand ( f.m. 1.8 to 2.5 ) and cement in proportion of 4:2:1including supply of all materials, labour, side shuttering ifrequired and t&p etc. required for proper completion of work. 21 12 mm thick plaster with cement mortar consisting of one part of cement & six part of coarse sand ( 1:6 ) , minimum thickness not to be less then 10 mm including supply of all material, labour and t&p etc for proper completion of work. 22 12 mm thick plaster with cement mortar consisting of one part of cement & four part of coarse sand ( 1:4 ) , minimum thickness not to be less then 10 mm including supply of all material, labour and t&p etc for proper completion of work. 23 making drip course ( 25x12 ) mm in 1:2 cement and course sandincluding supply of all materials, labour and t&p etc requiredfor proper completion of work. 24 providing ( 12x15 ) mm section groove in plasterincluding all material, labour andt&p etc. required for proper completion of the work. 25 local sand filling in plinth including supply of necessary quantity oflocal sand from outside the uppcl premises including watering, dressing etc. rate to include cost of all materials, labour and t&p etc. required for proper completion of work. 26 concrete with 4cm gaugestone ballast, coarse sand ( f.m. 1.8 to 2.5 ) &cement inproportion of 12:6:1 in foundations &under floors including supply of all materials, labour and tools and plants etc. required for proper completion. 27 providing and laying floor of 10 mm thick industrial tiles in flooring or skirting of approved brand ( bell, johnson or equi. make ) size of 300x300 mmof approved shade, colour and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cementmixed with pigment to match the shade of tile including cost of all material, labour and t&p required for proper completion of the work. 28 supply and laying 8 mm thickglazed floor tiles of somany, johnson or equivalent make, laid with1:3 cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supplyof all materials, labour and t&p etc. completion required for proper completion of the work. 29 supply and laying 6 mm thickglazed tiles in skirting / dado laid with1:3 cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supplyof all materials, labour and t&p etc. completion required for proper completion of the work. 30 providing and laying floor of 8 mm thick vitrifiedtiles in flooring or skirting of approved brand ( bell, johnson or equi. make ) size of 600x600 mmof approved shade, colour and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cementmixed with pigment to match the shade of tile including cost of all material, labour and t&p required for proper completion of the work. 31 providing and fixing first quality white glazed orissa pattern w.c.pan hindustan, cera make. size 580 mm. ( hindustan, cera make ) with providing and fixing 100 mm dia white glazed p or s trap including cement concrete and all materials, labour cartage t&p etc.required for proper completion of the work. ( for w.c. ) 32 clearing jungle including uprooting of rank vegetations, grass, bush, wood, trees and saplings of girth upto 30cm measured at a height of 1.0m above ground level and removal of rubbish upto a distance of 50m outside the periphery of uppcl area cleared. 33 excavation in foundation in ordinary soil ( loam clay or sand ) including lift upto 1.5m and lead upto 30m and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of the foundation work. 34 first class brick ( class 150 ) work in 1:6 cement and coarse sand ( f.m.1.8 to 2.5 ) mortar in foundation and plinth including supply of allmaterials, labour & t&p etc. required for proper completion of work. 35 earth filling under floors and / or sub station area including cost of earth when obtained from with in 8 kmoutside uppcl area including its roylty and carriage including watering, ramming in 20 cm layers and dressing of earth etc. all complete. 36 providing and fixing glass strips of 3.15 mm thickness & 40mm depth in jointsof floor and skirting at the time of laying floors, flush withfloor level including supply of all materials, labour& t&p etc. completion required for proper completion of work. 37 4.0 cm thick 1:2:4 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified without base concreteand removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and t&p etc, required for proper completion of the work. 38 applying birla or equivalent putty on new interior or exterior surface over one coat of water based cement primer of ici or equivalent brand for smoothening and levelling of the surface as per requirement and direction of engineer i / c including cost of all material, labour, t & p etc required for proper completion of work. 39 supply and fixing of 32 mm thick single leaf flush door shutter ( boiled water resistance, phenol maldehide resin bonded, hot pressed factory made ) commercial quality to i.s.2202 part 1 ( 1983 ) isi marked including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts.locks, handles, springs and other fittings and includingtheir supply andall materials, labour & t&p etc. required for proper completion of work. 40 providing and fixing steel glazed window and ventilators ofstandard rolled mann or mahavir steel sections conforming to is7452 1974 as per drawing joints metered & welded with 100x14x3.15 mm holdfast embedded in cement concrete block 15x10x10 cm. size of 1:3:6 proportion i.e. first part of cement 3 part of approved coarse sand & 6 part of graded stone ( aggregated 20mm. nominal size ) s / f of glass panes of plain pin headed 4mm. thick nuts glazing clips and special putty of approved make complete and including a cost of red oxide paint. the fabrication should conform to i.s.1038 1975. ( aluminum beading with rubber packing included ) . 41 supplying & fixing 24 gauge annodized aluminium sheet of approved quality including cutting, wastage and fixing the same over the wooden door shutters with nails with all material, labour and t&p. 42 supply and fixing galvanised mosquito proof jali ( 16x24 gauge ) withm.s. flat of 20 x 3 mm. size, on both sides screwed or welded to windowor door frame. 43 finishing of walls with water proof exterior emulsion paintofaceofasianpaintsorequialentmake including 3 coats of above paint including one priming coat on already well prepared new wall surface to give an even shade including cost of all materials, labour & t&p etc. complete for proper completion of the work. 44 painting two coat with acrylic emulsion paint of berger / asian / ici or equivalent paint ( paint and water in the ratio 1:1 by volume ) over prepared and primed surface of cement concrete, cement plaster and bricks including all labour, material and t&p etc required for proper completion of the work, ( preparation of base with birla putty etc. and a coating of primer shall be paid extra ) . 45 painting or varnishing new iron works or new wood work with one coat of ready mixed priming paint and two coat approved superior quality ready mixed paint luxol or equivalent brand or varnish including supply of all materials, labour and t&p etc required for proper completion of the work. 46 cleaning of septic tank including disposal of waste out side the uppcl area as per direction of the engineer in charge including cost of all labour, t&p etc.required for proper completion of the work. 47 cleaning of grass and removal of rubbish upto a distance of 50 moutside the uppcl area cleaned. 48 first class bricks on edge floor laid dry, joints sand filled, including preparation of base to proper slope and its rammingincluding supply of all material labour & t&p etc. required forproper completion of the work. 49 supply and filling brick bat in soak pit including all labour, material and t&p etc complete. ( for 01 soak pit ) 50 first class brick ( class 150 ) laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0m depthincluding cutting moulding bricks as required including cost ofall materials labour and t&p complete. 51 supply and installation of india mark hand pump ii including 150 mm dia , 70m deep boring up to second starta including supply and lowering 110mm to 63mm dia pvc pipe ( 24m 110mm & 44m, 63mm, 6 kg / sq.m ) with required strainer, reducer joining 90 mm dia long cylinder, 32mm dia gi pipe 3mlong including supply anf filling of course sand of approved quality ( approx. .15 cum ) including developing the bore well to achive clear and sand free water for continous 60 min. including cost of all material, labour and t&p and its cartage for installation of hand pump complete as per drawing including construction of 1.85 m dia chabutara with excavation of earth and laying 25mm c.c. floor 1:2:4 with cement, c.sand and 20mm stone ballast with water proofing compound over 100 mm thick c.c. 1:6:12 with cement, c.sand and 40 mm brick ballast and making side edge 115mm thick and 300 mm deep with brick work 1:4 and plaster the same with 1:4 mix with neat cement finish also including 115 mm wide drain in 1:4 brick work & plaster all around the periphery of plateform complete including supply of all materials, labour and t&p etc required for proper completion of work. rate as per se, 7th mandal, up jal nigam, gorakhpur letter no 1045 dt 16.02.15 ( csi no.28.10 ) 52 providingand fixing of 110 mm dia pvc pipe 6 kg / sq.cm for withspecial such as tee, bend, socket, elbow etc including supply of all labour , material t&p etc. complete required for proper completion of the work. 53 wiring point for light with 1.5sq.mm fr pvc insulated multistrand single copper conductor cable in pvc conduit pipe concealed in the wall, complete with 14 swg copper continuity wire, piano. type switch & ceiling rose / single / batten holder on 3mm. thick pheno.lic laminated backelite sheet etc. complete in all respect, as directed by e / i.including matching colour wash. 54 wiring point for fan / fresh air fan with 1.5sq.mm fr pvc insulated multistrand single copper conductor cable in pvc conduit pipe concealed in the wall, complete with 14 swg copper continuity wire, piano. type switch & ceiling roseon 3mm. thick pheno.lic laminated backelite sheet etc. complete in all respect, as directed by e / i. including matching colour wash. 55 wiring point for plug with 1.5sq.mm fr pvc insulated multistrand single copper conductor cable in pvc conduit pipe concealed in the wall, complete with 14 swg copper continuity wire, piano. type switch and socket etc.complete in all respect as directed by e / i. including matching colour wash. 56 supply and fixing of power plug with 15a / 250volt flush type switch and 5 pin 15a / 250v flush type universal socket in suitable m.s. box of 175mmx100mmx50mm size with pheno.ic laminated bakelite sheet cover 3mm thick fixed with brass machinne screw and cup washer etc.required for proper completion of work as directed by e / i. 57 s / f of led fluorescent tube light fitting make, bajaj, phillips etc. suitable for 1x18 watt fluorescent tube complete including tubes etc. on surface complete in all respects required for proper completion of work as directed by e / i. 58 p / f of 12 watt led bulb of approved make bajaj, phillips etc.including all materials, labour t&p etc required for proper completion of work as directed by e / i. 59 s / f of ceiling fan make usha, bajaj etc. or its equivalent includling cost of all mterials labour and t&p etc. required for proper completion of work as per as approved by e / i. 60 p / f of 63 ampd.p. isolater ( legrand lexic ) as per approved by e / i. including all materials, labour t&p etc required for proper completion of work as directed by e / i. 61 s / f of mcb 6 amp to 32amp ( legrand lexic ) including all materials, labour t&p etc required for proper completion of work as directed by e / i. 62 supply and fixing surface / flush mounting 8 ways spn distribution board with additional metal door without mcb complete in all respect, as directed by engineer in charge. 63 supply and buring of safe earthing electrode t 19 ( hot dip galvanized ) , length up to 3000mm, outer pipe 50mm, inner pipe 25, terminal dia 12 mm , outer gi pipe of 16 swg and inner gi pipe of 12 swg with hot dip galvanization up to 100 micron filled with crystalling conductive mixture ( ccm ) having anti corrosive & conductive property with 50 kgs activated soil ( bfc ) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square c.i. frame with hinged cover & masonry husing ( from electrode terminal to switch board , cost of 25x3 g.i. strip will beextra ) 64 supply and wiring of submain with two number 2.5 sq.mm. fr pvc insulated 1100 v grade multistrand single core copper conductor cable in 20mm dia heavy duty ( 2mm thick ) pvc conduit with 1 number 1.5 sq.mm. fr pvcearth continuity wire complete in all respect including matching colour wash etc. complete in all respect. 65 supply and wiring of submain with two number 4 sq.mm in pvc insulated 1100v grade multistrand single core copper conductor cable in 20 mm dia heavy duty ( 2mmthick ) pvc conduit concealed in wall, complete with one number 2.5 sqmm. copper cable as earth continuity wire etc. complet in all respect 66 s / f of electronic fan regulator 120 280 v. isi marked, on the existing switch board including making connections, required material, labour t&p etc. for proper completion of work to the satisfaction of engineer in charge of work. 67 supply and wiring of submain with two no.. 1.5 sqmm frlsh pvc insulated 1100 v grade multi strand single core copper conductor cable in 20 mm dia heavy duty ( 2 mm thick ) pvc conduit concealed in the wall with one no.. 1.5 sq.mm. frlsh pvc insulated 1100 v grade multistrand single core copper conductor cable as earth continuty wire including matching colour wash etc complete in all respect. 68 s / f of switch box made up to 16swg ( 1.5mm ) thick m.s. sheet of 100x100x65mm size duly painted with red oxide primer and flushed in wall ineluding cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s / o all materials, labour and t&p required for proper completion of work as directed a site by the e / i. 69 same as item no. 68 but of 150x150x65mm size 70 same as item no. 68 but of 175x250x65mm size 71 same as item no. 68 but of 200x250x65mm size 72 supply and fixing of factory wired integral led flood light luminaires with die cast aluminium housing built with dirver set suitable for 70 to 90 watt. confirming to ip 65 protection complete in all respect. 73 supply and fixing of electronc fan regulator ( modular ) 120 280 v. isi marked, on the existing switch board including making connections, required material, labour t&p etc. for proper completion of work to the satisfaction of engineer in charge of work. 74 add for light / fan points with modular type switch in place of piano type switch. 75 add for plug points with modularswitch and socket in place of piano type switch and socket...
35517094 construction of dth bore well and dth recharge well under munpl project affected villages prayagraj...
35476149 tender for construction of dth bore well and dth recharge well under munpl project. 2) construction of filtration chamber and silt chamber for rain water harvesting system under munpl prayagraj....
35334107 repairing 01 nos bore well at gc crpf rampur, up...
35151970 provision of new bore well in staff quarters compound at orai in district jalaun....
35074266 tender for provision of bore well for hpo deoria....
34895004 tender for repairing 01 nos bore well at gc crpf rampur up...
34853349 repair and painting of electric pole, erection of overhead line repair of electric pole plinth and painting of electrical poles and erection of overhead line from ring road to new bore well near dav school in main campus bored by central ground water commission ( for detailed specification of work to be completed, refer to serial nos. 1 to 18 of financial bid document bill of quantity table ) ...
34814298 supply of different kind of bore well submersible motor pump set for the replacement of old ksb make pumps. , supply of different kind of bore wellsubmersible motor pump set for the replacement of old ksb make pumps. , cora12c/10 +umai100 (2.2/22) 3hp, head range 67 26 mtr., bore size 100 mm, discharge 00 14 m3/hour(0 233 lpm) , cora18c/14 +umai100 (3.7/22) 5hp, head range 71 34 mtr., bore size 100 mm, discharge 00 20 m3/hour(0 400 lpm) , cora18c/20 +umai100 (5.5/22) 7.5hp, head range 119 32 mtr., bore size 100 mm, discharge 00 20 m3/hour(0 400 lpm) , bpha/2d +uma8/22 10hp, head range 35 25 mtr., bore size 200 mm, discharge 50 90 m3/hour(1500 lpm) , bpha333/ 3d+umai 13/22 15hp, head range 52 38 mtr., bore size 200 mm, discharge 50 110 m3/hour(1800 lpm) , bpha384/ 2d+hbc(203) 20hp, head range 48 35 mtr., bore size 200 mm, discharge 50 110 m3/hour(1800 lpm) , bpha384/ 3g+hbc(253) 25hp, head range 62 32 mtr., bore size 300 mm, discharge 60 70 m3/hour(1100 lpm) , bpha384/ 3d+hbc(303) 30hp, head range 72 50 mtr., bore size 300 mm, discharge 60 70 m3/hour(1100 lpm)...
34644984 bids are invited for bore well rig air hose 2 inch unf connection 5750mm st st with spring r2 , 1 1 or 4inch x 5 mtr st st with spring guard power flex 300 bar , 3 or 8 inch x 5mtr st st , air hose 2inch with 2 1 and 2inch unf conn st st 40 70bar 30 mtrs , coolant castrol radicool heavy duty , hydraulic oil starol hydstar aw 68 total quantity : 125...
34644430 bids are invited for construction of new bore well permission for boring at firozabad site as per sor 1 scc sow tender document , testing of under ground water level as per sor 2 scc sow tender document , boring as per sor 3 scc sow tender document , supply of 200mm pvc pipe as per sor 4 scc sow tender document , gravel as per sor 5 scc sow tender document , submersible pump as per sor 6 scc sow tender document , suction discharge pipe as per sor 7 scc sow tender document total quantity : 1608...
34565816 redevelopment of bore well and repair replacement to old/unsv/correded column pipe unsv submersible cable nrv sluice valve valve pit chamber and certain misc work at lucknow cantt under ge e/m lucknow...
34513894 supply of different kind of bore well submersible motor pump set for the replacement of old ksb make pumps. , supply of different kind of bore wellsubmersible motor pump set for the replacement of old ksb make pumps. , cora12c/10 +umai100 (2.2/22) 3hp, head range 67 26 mtr., bore size 100 mm, discharge 00 14 m3/hour(0 233 lpm) , cora18c/14 +umai100 (3.7/22) 5hp, head range 71 34 mtr., bore size 100 mm, discharge 00 20 m3/hour(0 400 lpm) , cora18c/20 +umai100 (5.5/22) 7.5hp, head range 119 32 mtr., bore size 100 mm, discharge 00 20 m3/hour(0 400 lpm) , bpha/2d +uma8/22 10hp, head range 35 25 mtr., bore size 200 mm, discharge 50 90 m3/hour(1500 lpm) , bpha333/ 3d+umai 13/22 15hp, head range 52 38 mtr., bore size 200 mm, discharge 50 110 m3/hour(1800 lpm) , bpha384/ 2d+hbc(203) 20hp, head range 48 35 mtr., bore size 200 mm, discharge 50 110 m3/hour(1800 lpm) , bpha384/ 3g+hbc(253) 25hp, head range 62 32 mtr., bore size 300 mm, discharge 60 70 m3/hour(1100 lpm) , bpha384/ 3d+hbc(303) 30hp, head range 72 50 mtr., bore size 300 mm, discharge 60 70 m3/hour(1100 lpm)...
34263897 maintenance and operation of electrical and mechanical installations at epfo office building at gomti nagar, lucknow ( sh: providing and replacement of water supply pump in existing bore well ) ...
34239338 redevelopment of bore well and repair replacement to old / unsv / correded column pipe unsv submersible cable nrv sluice valve valve pit chamber and certain misc work at lucknow cantt under ge e / m lucknow ...
34223719 repair and renovation work for rashtriya raksha university, transit campus at dr. smnru university, lucknow repair and renovation work for rashtriya raksha university, transit campus at dr. smnru university, lucknow , dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead , demolishing r.c.c. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge , demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge.in cement mortar , demolishing rb work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge.in cement mortar , dismantling doors, windows and clerestory windows ( steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :of area beyond 3 sq. metres , dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. for thickness of tiles 10 mm to 25 mm , earth work in excavation by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan ) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by engineer incharge. , 1:4:8 ( 1 cement : 4 coarse sand ( zone iii ) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources ) , providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth beam : , same as item no 5 above , 1:1.5:3 ( 1 cement : 1.5 coarse sand ( zone iii ) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources ) ( foundation ) , same as item no 5 above , 1:1.5:3 ( 1 cement : 1.5 coarse sand ( zone iii ) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources ) ( column ) , reinforced cement concrete work in walls ( any thickness ) , including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 ( 1 cement : 1.5 coarse sand ( zone iii ) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources ) , steel reinforcement for r.c.c. work including traightening, cutting, bending, placing in position and binding all complete upto plinth level. mild steel and medium tensile steel bars , brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in foundation below plinth level up to floor v level in all shapes and sizes in : cement mortar 1:6 ( 1 cement : 6 coarse sand ) , brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : cement mortar 1:6 ( 1 cement : 6 coarse sand ) , half brick masonry with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. cement mortar 1:4 ( 1 cement :4 coarse sand ) , supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. , diluting and injecting chemical emulsion for post constructional anti termite treatment ( excluding the cost of chemical emulsion ) : treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 ( 1 cement : 2 coarse sand ) to match the existing floor:with chlorpyriphos / lindane e.c. 20% with 1% concentration , kota stone slab flooring over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : 25 mm thick , kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. , steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished seamless type tubes , providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces ) , excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gm / m² , providing ridges or hips of width 60 cm overall width plain g.s. sheet fixed with polymer coated j or l hooks, bolts and nuts 8 mm dia g.i. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm / m² , providing and fixing 15 cm wide, 45 cm overall semi circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm / m² , providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including isi marked stainless steel butt hinges with necessary screws , m.s.work in d / w hold fast , m.s.work in d / w m.s.grill , z section windows , providing and fixing angle iron frames for doors of mild steel angle sections , 15 mm cement plaster of mix : 1:6 ( 1 cement: 6 coarse sand ) , 12 mm cement plaster of mix : 1:6 ( 1 cement: 6 coarse sand ) , 12 mm cement plaster of mix : 1:6 ( 1 cement: 6 coarse sand ) , providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work ( two or more coats ) over and including water thinnable priming coat with cement primer , finishing walls with acrylic smooth exterior paint with silicone additives of required shade new work ( two or more coats applied @ 1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , ( d ) finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. ( e ) the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“all above operations to be done in order and as directed and specified by the engineer in charge : 22.7.1 with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works , painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work , with ready mixed pink or grey primer of approved brand and manufacture on wood work ( hard and soft wood ) , painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work , providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes , providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , providing and laying vitrified tiles in different sizes ( thickness to be specified by manufacturer ) , with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 ( 1 cement: 3 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joint with white cement & matching pigments etc. complete. size of tile 600x600 mm , providing and laying rectified glazed ceramic floor tiles of size 300x300 mm or more ( thickness to be specified by the manufacturer ) , of 1st quality conforming to is : 15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigments etc., complete. , design supply & installation of suspended spider glazing system designed to withstand the wind pressure as per is 875 ( part iii ) . the suspended system held with spider fittings of ss 316 grade steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with ss 316 grade stainless steel spider & bolt assembly with laminated glass fins 21 mm thick. the glass fins and glass panel assembly shall be connected to slab / beams by means of ss 316 grade stainless steel brackets & anchor bolts and at the bottom using ss channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, teflon / nylon bushes and separators to prevent bi metallic contacts, all complete to perform as per specification and approved drawings. the complete system to be designed to accommodate thermal expansion & seismic movements etc. the joints between glass panels ( 6 to 8 mm ) and gaps at the perimeter & in u channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. the rate shall include all design, engineering and shop drawing including approval from structural designer, labour, t&p, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, buffer plates, fastener, anchors, ss channel laminated glass etc. all complete. for the purpose of payment, actual elevation area of glazing including thickness of joints and the portion of glass panel inside the ss channel shall be measured. , steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. , p / f curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with c.p. brass screws and wooden plugs etc. wherever necessary complete ( a ) 25 mm dia. , providing & fixing fly proof wire gauze to windows, clerestory windows & doors with m.s. flat 15x3 mm and nuts & boltscomplete.stainless steel ( grade 304 ) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. , providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of size 595x595 mm of approved texture, design and patterns having nrc ( noise reduction coefficient ) of 0.50 ( minimum ) as per is 8225:1987, light reflectance of 85% ( minimum ) . non combustible as per bs:476 ( part 4 ) , fire performance as per bs:476 ( part 6 &7 ) , humidity resistance of 100%, thermal conductivity < 0.043 w / m k as per astm 518:1991, in true horizontal level suspended on interlocking metal powder coated t grid of hot dipped galvanised iron section of 0.40 mm thick on silhouette profile, rotary stiched double webbed white with 6mm reveal profile ( white / black ) , comprising of main t runners of size 15x42mm of length 3000 mm, cross t of size 15x42 mm of length 1200 mm and secondary intermediate cross t of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items ( galvanizing @ 80 grams per sqm ) i.e. 50 mm long, 8 mm outer diameter m 6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and l shape level adjuster of size 85x25x2 mm. galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall s.s screws. the work shall be carried out as per specifications, drawing and as per directions of the engineer in charge. with 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles , applying priming coat: with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works , painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is:13592 type a, including jointingwithsealringconformingtois: 5382, leaving 10 mm gap for thermal expansion. single push fit coupler110 mm dia , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is:13592 type a, including jointingwithsealringconformingtois: 5382, leaving 10 mm gap for thermal expansion.shoe ( plain ) 110 mm shoe , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is:13592 type a, including jointingwithsealringconformingtois: 5382, leaving 10 mm gap for thermal expansion. plain bend 87.5 deg 110 mm dia , providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 110 mm , fixing of door chaukhats , providing & fixing stainless steel sliding door bolts isi marked anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade with nuts and screws etc complete. ( a ) 250mm x 16mm . , providing and fixing stainless steel towerbolts ( barrel type ) with necessary screws etc. complete ( a ) 300 mm x 10mm , providing and fixing stainless steel handles with screws etc. complete ( a ) 125 mm , providing & supplying curtains. , cc flooring with 1:2:4 with 40 mm thick , cement plaster up 30 cm heght with 1:3 cement sand morter , providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes. 110 mm diameter , wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. , wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required.2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire , wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 4 x 16 sq. mm + 2 x 6 sq. mm earth wire , supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15 / 16 a socket outlet 3 pin 5 / 6 a socket outlet , supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15 / 16 a socket outlet 15 / 16 a socket outlet , installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. , installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. upto 450 mm sweep , providing and fixing circular / hexagonal g.i. box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick g.i. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the g.i. box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. ( dsr civil 2014 item no. 10.18 ) , supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , supply and fixing of1x22 watt led tube light ( surface ) complete in all respect. , supply and fixing of36 46 watt recess mounting led square light complete in all respect. , supply and fixing of15w 18w led down lighter complete in all respect. , supply and fixing of 17 watt led mirror light and complete in all respect. , supply and fixing of10w 15w led cealing light complete in all respect. , supply and fixing ofwall mounted light fixture complete in all respect. , supply and erection of ac 230 / 250 volts, 50 hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.300mm sweep. , supply and erection of ac 1200mm sweep, 230 / 250 volts, 50 hz ceilling fan with down rod, blades including connection etc. complete as required , supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 a , supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 63 a , s&f of 100 a, 16 ka, tpmccb mccbthermal magnetic release , s&f of 125 a, 16 ka, tpmccb mccbthermal magnetic release , earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. ( but without charcoal / coke and salt ) as required. , supplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. , providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. , supplying and fixingfollowing size / modules, gi box along with modular base& cover plate for modular switches in recess etc as required. 1 or 2 module ( 75mm x 75 mm ) , supplying and fixing following modular switch / socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. telephone socket outlet , supplying and drawing telephone wire following pair 0.5 sqmm fr pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel / pvc conduit as required. 2 pair , supply and fixing of36 watt led hanging light complete in all respect. , supply and erection of ac 1400mm sweep, 230 / 250 volts, 50 hz ceilling fan with down rod, blades including connection etc. complete as required , supplying and fixing extra conduit down rod of 60 cm length g.i. pipe 15 mm dia, heavy gauge including painting etc. as required. , numbering of ceiling fan / exhaust fan / fluorescent fittings as required. , providing and fixing water closet squatting pan ( indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , providing & fixing toilet paper holder c.p. brass , providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge. , providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: white vitreous china wash basin size 630x450 mm with a single 15 mm c.p. brass pillar tap , providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge. , providing and fixing ptmt towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. , providing and fixing ptmt soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. , providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 ( including angle valve for wc flushing cistern, jet & kitchen sink ) 15 mm nominal bore , providing and fixing uplasticised pvc connection pipe with brass unions :45 cm length 15 mm nominal bore , providing and fixing stainless steel aisi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting offittings and brackets, cuttingandmakinggoodthe walls wherever requiredkitchen sink with drain board 510x1040 mm bowl depth 200 mm , providing & fixing pvc waste pipe for sink including pvc waste fittings complete flexible pipe 32mm dia , providing and fixing 600x450 mm beveled edge mirror of superior glass ( of approved quality ) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. , providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 15mm nominal bore , providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 15mm nominal bore , providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge. , providing and fixing ptmt bottle trap for urinal. bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms , providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size ) as perdirection of engineer in charge and finished smooth.granite stone of approved shade , providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia pipes , providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia pipes , providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia pipes , providing and fixing brass stop cock of approved quality : 15 mm nominal bore , providing and fixing brass stop cock of approved quality : 20 mm nominal bore , providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) :for vertical pipe connection with terrace ringmain 25mm nominal bore , providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) :for vertical pipe connection with terrace ringmain 32mm nominal bore , providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is :13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes.110 mm dia ( for rain water ) , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is:13592 type a, including jointingwithsealringconformingtois: 5382, leaving 10 mm gap for thermal expansion. single push fit coupler 110 mm dia , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is:13592 type a, including jointingwithsealringconformingtois: 5382, leaving 10 mm gap for thermal expansion. single tee with door 110x110x110 mm , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is:13592 type a, including jointingwithsealringconformingtois: 5382, leaving 10 mm gap for thermal expansion.plain bend 87.5 deg 110 mm dia , providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. , providing and placing on terrace ( at all floor levels ) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. , providing, fixing, jointing and testing, upvclow noise swrhaving noise insulation less than 10db at 2lps flow rate pipeto wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. ( i ) single socketed pipes. internal toilet ( soil & waste pipe ) 75 mm , providing, fixing, jointing and testing, upvclow noise swrhaving noise insulation less than 10db at 2lps flow rate pipeto wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. ( i ) single socketed pipes. internal toilet ( soil & waste pipe ) 110 mm , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. bend without door ( 87.5° ) 110mm bend , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. bend without door ( 87.5° ) 75mm bend , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. bend without door ( 45° ) 100mm , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. bend without door ( 45° ) 75mm , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.single tee without door 110mm , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. single tee without door75 mm , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. coupler 110mm , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. clean out plug ( cop 110mm , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. clean out plug ( cop 75 mm , providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. vent cow l110mm , providing, fixing, jointing and testing , oflow noise pvc multi floor trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by engineer in charge.110mm x 75mm x 50mm / 40mm ( toilet ) , providing, fixing, jointing and testing , oflow noise pvc nahanitrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by engineer in charge.110mm x 75mm ( toilet ) , providing and fixing ptmt grating of approved quality and colour.rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating ( including balcony ) , providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :150 x 100mm size p typewith common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , supply and fixing of36 watt led hanging light complete in all respect. , supply and erection of ac 1400mm sweep, 230 / 250 volts, 50 hz ceilling fan with down rod, blades including connection etc. complete as required , supplying and fixing extra conduit down rod of 60 cm length g.i. pipe 15 mm dia, heavy gauge including painting etc. as required. , numbering of ceiling fan / exhaust fan / fluorescent fittings as required. , boring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in is: 2800 ( part i ) , including collecting samples from different strata, preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90 metre depth below ground level.300mm dia 300 mm dia , boring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in is: 2800 ( part i ) , including collecting samples from different strata, preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in harge, beyond 90 metre & upto 150 metre depth below round level.300 mm dia , supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized pvc medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of engineer in charge. 150 mm nominal size dia , supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized pvc medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of engineer in charge. 200 mm nominal size dia , supplying, assembling, lowering and fixing in vertical position in bore well unplasticized pvc medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including hire & labour charges, fittings &accessories etc. all complete, for all depths, as per direction of engineer in charge.150 mm nominal size dia , supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of engineer incharge. 3.14* ( .150*.150 .075*.075 ) *150 , development of tube well in accordance with is : 2800 ( part i ) and is:11189, to establish maximum rate of usable water yield without sand content ( beyond permissible limit ) , with required capacity ai compressor, running the compressor for required time till well is fully developed, measuring yield of well by “v” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i / c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of engineer in charge. , providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore wellhousing / casing pipe, removable as per requirement, all complete for borewell of:200 mm dia , providing and fixing m.s. clamp of required dia to the top of casing / housing pipe of tubewell as per is: 2800 ( part i ) , including necessary bolts & nuts of required size complete.200 mm clamp. , providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tubewell as per is:2800 ( part i ) . 200 mm dia. , supply and fixing of tube well pump 10.0 h.p. cable and other necessary all materils.ksb make or equvilent , water supply of tanker 5000 litre capacity of boring , supply and fixing of nylon jali around the slotted pipes complete as required up to 10 mtr. , supply of 80mm dia m.s. column pipe of class c both and socketed with heavy sockets in 3 / 6 meter length and one end flanged complete with interlocking arrangements. , supply of 80mm dia m.s. column pipe clamps with nut bolts packing etc. , excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth pipes 80 mm to 300 mmdiameter , excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 1.50 m to 3.00 m depth pipes 80 mm to 300 mmdiameter , opentimbering in trenches including shuttering and shoring complete. ( measurement to be taken of the face area timbered ) depth not exceeding 1.5 meter , opentimbering in trenches including shuttering and shoring complete. ( measurement to be taken of the face area timbered ) depth 1.5 to3.00meter , providing and laying nonpressurenp 2 class ( light duty ) rcc pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 ( 1cement : 2 finesand ) includingtestingof joints etc. complete.150 mm.dia. rccpipes , providing and laying nonpressurenp 2 class ( light duty ) rcc pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 ( 1cement : 2 finesand ) includingtestingof joints etc. complete.250 mm.dia. rccpipes , providing and laying cement concrete 1:5:10 ( 1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size ) upto the haunches of pipes including bed concrete as per standard design150 mm.dia. rccpipes , providing and laying cement concrete 1:5:10 ( 1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size ) upto the haunches of pipes including bed concrete as per standard design 250 mm.dia. rccpipes , constructing brick masonry manhole in cement mortar 1:4 ( 1 cement :4 coarse sand ) rcc top slab with 1:2:4 mix ( 1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size ) , foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size ) inside plastering 12mm thick with cement mortar 1:3 ( 1 cement :3 coarse sand ) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 ( 1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size ) finished with a floating coat of neat cement complete as per standard design. , inside size 90x80cms and 45cms deep including ci cover with frame ( light duty ) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15kg ) .with common burnt clay fps ( non modular ) bricks of class designation 75 ( i ) for sewer line , extra for depth for manholes:size 90x80cm with with common burnt clay fps ( non modular ) bricks of class designation 7.5 , inside size 90x120cms and 90cms deep including ci cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58kg ) . with common burnt clay fps ( non modular ) bricks of class designation 75 ( i ) for sewer line , extra for depth for manholes: size 90x120cm with with common burnt clay fps ( non modular ) bricks of class designation 7.5 , providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per is:10910 on 12 mm dia steel bar , p / laying of interlocking road , p / making storm water drain 300*450 mm , p / f of chain link fencing wall , p / making of gate , site clearing , surface drasing , cost of signage , cost of notice board , cost of biomatric , interactive board, interactive diagonal: 1975 mm, usb powered, infrared, multi touch ( 6 touch ) , supports windows xp, vista, windows 7, windows 8, window 10 and linux + ceramic steel board size: 120 x 180 cm make: romark / globus / brio.with resolution xga 1024x768 , 3200 ansi lumen, hdmi / vga inputs and inclusive of ceiling / wall mount kit, all cables connector and conduits etc. make: benq, globus, ricoh with digital / smart podium: the podium shall be wheel mounted capable of moving in all directions with a facility of lock them while the electronic podium is in use. the enclosure shall be made of polymer powder coated steel body with wooden top panels, designed to work in suitable environmental conditions. the wooden top shall have lock and key and should have a sliding cover for opening / closing easily. the podium should have housing and connectivity for visual presenter while the visualizer is in use and not in use. at the time of using the visualiser , drawer can be opened and visualiser can be used. the construction of the podium should be such that, while the podium is locked and not is use, there should not be any port exposed / visible on the outer body for breakage / mishandling.built in highly sensitive interactive panel with adjustable tilt ( power driven motorized system ) & a mechanism to make the panel stable so that it does not shake while writingwith following minimum features.led 53.0 cm ( 21 inches ) or higher 1920 x 1080 or higherone usb, one vga / dviport 4000 lpi ( lines per inch ) approximately 200 points per second 2048 levels display panel should have inbuilt speakerdigital teaching device, controller, i5 pc with wi fi card inbuilt amplifier, speaker and with basic visualizer, no windows make : globus, brio. wall mount 1 kva ups with casingcomplete installation of the entire unit , workstation table, panel based partition, particle board edge banded top , high back chair, pu chrome arm, gas lift, chrome base, fabric tapestry synchro tilt , executive table, particle board top w1650 x d1900 x h750 , medium back chair, chrome cushion arm, gas lift, chrome base, leatheritte tapestry , visitor chair, chrome cushion arm, chrome plated pipe stand, leatheritte tapestry , executive table, particle board top , high back chair, chrome cushion arm, gas lift, chrome base, leatheritte tapestry , single seater sofa, wooden frame, ss pipe leg, size in mm 830 ( l ) x 780 ( d ) x 755 ( h ) leatherette , three seater sofa, wooden frame, ss pipe leg, size in mm 1825 ( l ) x 780 ( d ) x 755 ( h ) leatherette , centre table, ss pipe frame, chrome finish, toughned black glass, top 12mm thick, lower glass 8mm thick , cafe chair, without arm, ss pipe frame chrome finish, leatherite tapestry , café table, ss pipe frame chrome finish, granite top, size in mm 900 x 900 , dual desk, plpb edge banded top, seat & back, powder coated pipe frame, top size 1050 x 400 x 18mm thick overall size 1050 x 980 x 750 two seater , workstation table, panel based partition, particle board edge banded top ( rs. 69500 / 4= rs.17375 ) , medium back chair, pipe chrome arm, gas lift, chrome base, leatherite tapestry swivel tilt , steel almirah, 2 glass doors, 4 adjustable shelf, thickness 0.8mm , student / traning room chair, pu arm, plpb folding writing pad, book trey under seat, powder coated pipe frame, fabric tapestry, marino 10002 top colour, writing pad size : 535 x 300 x 18 mm thick , single seater sofa, wooden frame, ss pipe leg, size in mm 830 ( l ) x 780 ( d ) x 755 ( h ) leatherette , three seater sofa, wooden frame, ss pipe leg, size in mm 1825 ( l ) x 780 ( d ) x 755 ( h ) leatherette , centre table, ss pipe frame, chrome finish, toughned black glass, top 12mm thick, lower glass 8mm thick , conference table, particle board edge banded top w3600 x d1200 x h750 , high back chair, chrome cushion arm, gas lift, chrome base, leatheritte tapestry , cost of podium , s / i / t / c of split ac 2 ton , s / i / t / c of split ac 1.50ton , s / i / t / c of i7 16 gb ram , 512ssd , 1tb hdd with windows 10 and microsoft preloaded wire opticalmouse and keyboard with spekar and webcam , canon image runner c3226 with dadf and toner , hp colour laser mfp 178nw printer , s / i / t / c of sony tv kd55x75k in5 , supply of 63kva , 415 volts dg set , s / i / t / c of water cooler with r o system , cat6 utp cable ( 300m ) , i / o box dlink , path cable cat6 ( 1m ) , path cable cat6 ( 2m ) , ethernate 24 port gigabite managed l3 switch , 24 port patch panel , network box 6u rack , instalation charges , cat6 utp cable ( 100m ) , ethernate 16 port gigabite managed l3 switch , 16 port patch panel , network box 4u rack , ip camera ( bullet / dome ) , 8 port poe switch , 8 channel nvr , survillance hdd 4tb , cat 6 utp wire ( 100m ) , 4 u rack , 16 port poe switch , 16 channel nvr , cat 6 utp wire ( 300m ) , instalation of cc tv , cost of maono au 100 condenser clip on lavalier microfone with 6 m audio cable , cost of fire ectinguisher...
34107165 bids are invited for soil investigation for bore well (q3) total quantity : 1...
33919754 construction of interlocking road, drain, crossing, bore well, laying of pipe line....
33919390 construction of interlocking road, drain, crossing, culvert, pipe line laying work, construction of bore well....
33760403 construction of sub post office building at baragaon (jhansi) in agra region, up. ( sub head: provision of counters , cupboard ,writing ledge and bore well)...
33759957 tender for construction of panwari sub post office building under banda division in kanpur region in up circle (sh: provision of counters, cupboards, writing ledge, development of plot, storm water drain, cycle shed, soak pit and bore well)...
33711060 redevelopment of bore well and repair replacement to old/unsv/correded column pipe unsv submersible cable nrv sluice valve valve pit chamber and certain misc work at lucknow cantt under ge e/m lucknow ...
33572882 replacement of 1 no. of bore well at gorakhpur bp. => limited...