Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

39575017 tender for system strengthening works in municipal jhansi nagar under eudd ii, jhansi on semi turn key basis. 1 errection and supply details 2 local / de centralised items to supply 3 al lug 35 sq mm 4 al lug 70 sq mm 5 al lug 120 sq mm 6 al lug 150 sqmm 7 al lug 240 sq mm 8 al. lug 400 sqmm 9 lt cable jointing kit size 3.5x240 for tapping of lt line 10 11 kv jointing kit outdoor 120 sqmm 11 hs 11 kv cable jointing kit ( 3x70 ) sqmm i / d 12 hs 11 kv cable jointing kit ( 3x70 ) sqmm o / d 13 hs 11 kv cable jointing kit ( 3x70 ) sqmm s / t 14 hs 11 kv cable jointing kit ( 3x120 ) sqmm i / d 15 hs 11 kv cable jointing kit ( 3x120 ) sqmm 0 / d 16 hs 11 kv cable jointing kit ( 3x185 ) sqmm i / d 17 hs 11 kv cable jointing kit ( 3x185 ) sqmm o / d 18 hs 11 kv cable jointing kit ( 3x185 ) sqmm s / t 19 hs 11 kv cable jointing kit ( 3x240 ) sqmm i / d 20 hs 11 kv cable jointing kit ( 3x240 ) sqmm o / d 21 hs 11 kv cable jointing kit ( 3x240 ) sqmm s / t 22 hs 11 kv cable jointing kit ( 3x300 ) sqmm i / d 23 hs 11 kv cable jointing kit ( 3x300 ) sqmm o / d 24 hs 11 kv cable jointing kit ( 3x300 ) sqmm s / t 25 hs 33 kv cable jointing kit ( 3x50 ) sqmm i / d 26 hs 33 kv cable jointing kit ( 3x50 ) sqmm o / d 27 hs 33 kv cable jointing kit ( 3x50 ) sqmm s / t 28 hs 33 kv cable jointing kit ( 3x70 ) sqmm i / d 29 hs 33 kv cable jointing kit ( 3x70 ) sqmm o / d 30 hs 33 kv cable jointing kit ( 3x70 ) sqmm s / t 31 hs 33 kv cable jointing kit ( 3x120 ) sqmm i / d 32 hs 33 kv cable jointing kit ( 3x120 ) sqmm o / d 33 hs 33 kv cable jointing kit ( 3x120 ) sqmm s / t 34 hs 33 kv cable jointing kit ( 3x185 ) sqmm i / d 35 hs 33 kv cable jointing kit ( 3x185 ) sqmm o / d 36 hs 33 kv cable jointing kit ( 3x185 ) sqmm s / t 37 hs 33 kv cable jointing kit ( 3x240 ) sqmm i / d 38 hs 33 kv cable jointing kit ( 3x240 ) sqmm o / d 39 hs 33 kv cable jointing kit ( 3x240 ) sqmm s / t 40 hs 33 kv cable jointing kit ( 3x300 ) sqmm i / d 41 hs 33 kv cable jointing kit ( 3x300 ) sqmm o / d 42 hs 33 kv cable jointing kit ( 3x300 ) sqmm s / t 43 bolt nut and washer all size 44 end cap for ab cable 45 insulating mastic tape ( 2incx10feet ) 46 pg clamps 16 sqmm 50 sqmm ( for line to line jumpering ) 47 angle for vertical arm with fitting as per requirement 48 back clamp for height raising channel hloding calmps with bolt and nut 49 supply of lt pvc cable ( armoured ) 4*16 sqmm 50 supply of lt pvc cable ( armoured ) 2*6 / 10 sqmm 51 4x2.5 sq.mm 52 2x2.5 sq.mm 53 stone pad 54 alluminium binding wire 6 swg 55 jointing sleeve acsr dog 56 pg clamp for acsr dog 57 turn buckle 58 m.s. angle iron 65*65*6 mm, 4300 mm long bracing with clamp 59 eye bolt 60 nut & bolts with washers all size 61 feeder piller box panel with fuse unit & distribution bus bar having insulation of ip66 & above for installation in open area with locking arrangement complete in all respect. ( type c ) 62 lt rises lt incoming panel with protection& metering arrangement type b ( 250 amp mccb incomer & 3 no. o / g mccb 100 amp provision ) 63 pg clamp 16 sqmm 50 sqmm ( for line to line jumpering ) 64 cu. l clamp 65 ht tape for sealing of lt 66 11 kv ct metering / dlms unit complete 67 24 volt battery and battery charger with cabinet 68 barbed wire fencing with gate etc ( switchyard ) 69 ht tape 70 labels rating / number plates 71 tape chaging gear 72 11 kv danger board with clamps & bolts 73 barbed wire gi 74 gi pipe 6 dia 75 cable route & cable marker 76 tape volatge indicator digital type 77 local remort selector switch 78 buzzer and lamp to indicate tap changing in progress 79 buccholz relay 80 pressure relive valve 81 ground bond resitance / erath resistance tester 82 33 kv bushing for power transformer 83 11 kv bushing for power transformer 84 11 kv neutral bushing complete 85 winding temperature indicator 86 oil temperature indicator 87 insulated rubber mats for the electrical panels 88 current tranformers ( ct ) 600 / 400 / 5 a 89 current tranformers ( ct ) 400 / 200 / 5 a 90 current tranformers ( ct ) 200 / 100 / 5 a 91 potential transfomrer ( pt ) 11kv / 110v 92 control switches 93 alarm and indication lamp 94 various type of cable connectors 95 switch gear mimic diagram in red colour 96 mechanical interlocks for switch gear 97 supply of various type of circuit breaker operating mechanishm 98 11 kv over current and earth fault relays 99 33 kv over current and earth fault relays 100 under frequency replay 101 24 volt dc switch board 102 braething mask for fire fighting within the substation 103 plastic helmets 104 20 kv insulating gloves 105 suitable insulated stool 106 33 kv and 11 kv volatge indicator rod of the telescopic type 107 rechargeable torch light 108 portable carriage mounted fire exinguisher suitable fire electrical fire 109 instruction against electrical shocks and artificial breathing in hindi or english language 110 comlete set of safety regulation signs for open circuit , danger zone etc in hindi language 111 drawing and instruction books / chart 112 combined ct pt unit for pole metering 113 33 kv pt ( outdoor ) 33kv / 110v 114 silica gel 115 cable stippers 116 insulated screw driver 117 pliers 118 electricsl tape 119 hacksaw 120 cable cutter 121 spanner 122 volateg tester 123 safety knife 124 hex keys 125 claw hammer 126 chisel 127 electrician tool kit 128 5kv 10kv 15kv high voltage insulation resistance tester / megger 129 non conductive ladder made of wood or fiberglass 130 33kv ct 400 / 200 / 1 1 1a 131 no load fault locating machines required 132 fault pass indicators required 133 trolley with wheel and all required accessories 134 earthing of feeder piller box ( chemical / pipe / plate etc ) complete for cable 135 outdoor switchyard &approach road lighting 136 11 kv lightning arrester 137 4 core lt mcb with box lt incoming protection panel with metering equipment ( type a 100 to 500 amp 4pole mcb with box / lt protection panel ) 138 33 kv lightning arrestor 139 33 kv vcb with single t / f control pannel and ct 200 / 100 / 1 a with structure 140 33 kv vcb with doublet / f control pannel and ct 200 / 100 / 1 a with structure 141 erection / services of above items ( part b ) 142 m.s. & civil structure for feeder piller box installation 143 onsite maintenance and supply of required accesories pre installed capacitor bank and their accesories for succesfully operation such as over compensation, over voltage, over curent, erath fault, ammeters, kvar meteers and others 144 giving the genuine consumer service connection through installed lt distribution box including disconnection & reconnection 145 repairing of 9 / 11 m st / rsj pole by muffing and breaking cc / hard surface of rusted and tilted st pole and digging about 4 feet to prevent, grout and muffing with the help of stones etc in well made pits 146 trench work for lt line ( size 3x1.5 feet, brick work 9 inch wall, concreating in base, trench cover 4 inch, 2 section with ms channel ) 147 sundary charges for extra material i.e. cable glands, off size lugs, pvc pipe etc 148 number / dt code etc marking on pole by paint, yellow base will be prepared and number shall be written by black paint ( paint provided by contractor ) 149 plinth complete 150 wire mesh fencing with door complete 151 laying of 11 kv cable including cost of sand and bricks 152 making of 11kv cable boxes mounted with switch gear and transformer 153 making of 11 kv straighth thorugh 154 making of 33 kv cable boxesmounted with switch gear and transformer 155 painting of s / s structure 156 sundry stores 157 road restoration charges for pucca road 158 road restoration charges for kachha footpath side 159 concreting of poles 160 painting of pole with red oxide / silver oxide paint of two coat ( paint provided by contraction ) 161 number marking on pole by paint, yellow base will be prepared and number shall be written by black paint ( paint provided by contractor ) 162 repairing of plinth of power transformer 163 laying, sagging & binding of ab cable for construction of lt line. 164 laying acsr conductor weasel / racoon / dog 165 safe loading, carriage and unloading of pcc / st pole 13 / 11 / 09 / 8.5 mtr. long from esc hasari store / je store to work site. 166 safe loading, carriage & unloading of line material ( i.e. acsr conductor, 11kv cable. ab cable, other cables, ms material, clamps etc ) from esc hasari store / je store to work site. 167 erection of pcc / st pole 8.5 / 09 / 11 / 13 meter long sp 33 / 55 / 70 including fixing of all accessories for lt / ht / eht line complete with concreting & plinth. 168 erection of double pole structure with fixing of all accessories i.e. top channel, dropper channel, brasing angle, clamps etc including concreting of poles for section pole. 169 errection and making of 11 kv feeder isolation as per estimates 170 erection of tri pole structure with fixing of all accessories i.e. top channel, dropper channel, bracing, clamps etc including concreting of poles for rectanglen or turn 171 erection of four pole structure with fixing of all accessories i.e. top channel, dropper channel, bracing, clamps etc including concreting of poles for rectangle or turn 172 construction of double pole structure with st pole 11 mtr long sp 55 including fixing of all accessories complete with concreting & plinth for 25 / 63 / 100 kva, 11 / 0.4 kv pole mounted sub station. 173 construction of double pole structure with st pole 11 mtr long sp 55 including fixing of all accessories complete with concreting & plinth for 250 / 400 kva, 11 / 0.4 kv plinth mounted sub station. 174 earthing of pole by earthing rod, gi wire etc. complete 175 erection of stay set complete as per respo manual including their concreting. 176 laying of armoured cable size 4cx16 sqmm, 2cx6 / 10 sqmm for consumer service connection. 177 discoonection & recoonection of consumer connection for replacement of damage non armoured cable 178 painting of pole with red oxide paint & aluminium paint and numbering of pole with black over yellow base. 179 extra pit digging in hard stiff & uneven area as per reqiurement 180 laying of 11 kv cable of size 3x185 / 120 / 70 / 35 sq mm 11 kv as per site requirement 181 digging of horizontal boring under the highway / railway track for fixing of hdpe pipe for laying of 11 kv cable as per site requirement. 182 digging of cable trench and cover with first class bricks protection and filling the river sand including back filling by sandfor laying of 11 kv cable with fixing of hdpe / gi pipe ( as per need ) and cable route marker also complete. 183 chemical / pipe ( water level ) earthing ( as per requirement of site ) for 11 kv cable etc. 184 supply of gi pipe 6 dia if not available in store 185 supply of hdpe pipe ( pe63, 10kg / cm3, is 4984:1995 ) 6 dia or equivalent if not available in store 186 supply & fixing of pipe joints if not available in store 187 supply & fixing of cable route marker if not available in store 188 trimming & chopping of tree branches asper site requirement 189 dismentalling of o&u stp 190 dismantalling of st / rail / joist / pcc pole of lt / ht line short in length 191 dismantalling of line material ( acsr conductor, ab cable, cross arms, various clamps etc ) of ht 11 kv / lt line. 192 loading, carriage & unloading of existing poles & line material scrap from site to store. 193 extra r&m works on existing netwrok for strengthing 194 carriage of tf 25 / 63 / 100 kva 11 / 0.4 kv from esc hansari to perticuler site 195 carriage of tf 250 / 400 / 630 kva 11 / 0.4 kv from esc hansari to perticuler site 196 mounting of t / f 25 / 63 / 100 kva s / sfixing of 11 kv cable / jumfer and l.t.cable for energization of line and t / f 197 mounting of t / f 250 / 400 kva s / s fixing of 11 kv cable / jumfer and l.t.cable for energization ofline and t / f 198 dismentalling of 25 / 63 / 100 kva t / f ( o&u ) including carriage of t / f from working site to esc hansari store jhansi 199 dismentalling of 250 / 400 kva t / f ( o&u ) including carriage of t / f from working site to esc hansari store jhansi...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

38787169 electrification of household in pe / ue habitations at agra 1, agra 2, aligarh & kanpur zone under dvvnl, ( district agra, mainpuri, firozabad, mathura, aligarh, hathras, etah , kasganj, auriya , etawah, kannauj , farrukhabad, kanpur deha & kanpur nagar ) of uttar pradesh state under revamped reforms based and results linked, distribution sector scheme 2 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 3 stone pad ( 300x300x75mm ) 4 aerial bunched xlpe cable 3x50 ( ph ) + 1x35 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 5 aerial bunched xlpe cable 1x25 ( ph ) + 1x16 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 6 lt xlpe cable 4x16 sq mm 7 1x25 mm2 un armoured xlpe insulated al. lt cable for energising the distribution boxes. 8 acsr weasel conductor 9 acsr rabbit conductor jumpering works 10 aluminium binding wire 6 swg 11 11kv fuse set ( drop out ) 12 11kv tpmo 13 25 kva , 11 / 0.433 kv t / f ( level 1 self protected aluminium wound type ) 14 lt distribution box withmccb and ami metering ( smart meter compitable with system ) equipmen . ( smc type ) for 25kva ( drg no. rec / rdss / dtr / ss / 24 ) 15 9 kv la , 5 ka ( distribution class ) 16 earthing coil connected with nutbolt using bentonite powder 17 gi flat 25x3 for earthing 18 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 19 g.i. barbed wire 20 g.i. wire no. 16 swg for binding 21 g.i. wire 6 swg 22 g.i. wire 8 swg 23 11 kv disc fitting t & c type 24 11 kv polymer disc insulators45 knt&c type 25 11 kv pin insulator polymer type as per ts 26 dead end clamp ( insulated ) 27 end cap for ab cable 28 suspension clamps ( insulated ) 29 pole clamps with with i hook & nut & bolts for laying abc 30 insulating piercing connector ( 16 95 sq.mm ) 31 single phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with clamps ( 40x3 mm ) and nut & bolts 32 three phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with clamps ( 40x3 mm ) and nut & bolts 33 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 34 pg clamp for rabbit 35 gi stay wire 7 / 10 swg 36 ht guy insulator 37 lt guy insulator 38 stay complete ( gi stay rod 16x1800 mm 1 nos , eye bolt 1 nos, anchor plate 1 nos, turn buckle 1 nos, hellically formed end fitting, square washer and thimble, nuts bolt & washers ref drg rec / rdss / gen / 09 39 ht stay clamp as per approved drawing 11 kv 40 lt stay clamp as per approved drawing 41 pre fabricated galvanised steel items ( zinc 610gms / sqm ) , like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, tea off, guarding channels, back clamp, dts structure etc made of gs channels , gs angle , gs flats ( 50x8mm ) of given sizes for over head structures as per technical specification, approved drawings and scope of work. 42 gs nuts, bolts and washers as per technical specification, approved drawings and scope of work. 43 eye bolt 44 jointing sleave acsr weasel 45 11 kv danger board 46 11 kv number plate 47 sign board as per ts and approved drawing 48 erection part 49 survey , erection, testingand commissioning of 11 kv line ( complete work in all respect ) 50 route survey and pole spotting for 11 kv line 51 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 52 acsr weasel conductor 53 stone pad ( 300x300x75mm ) 54 pre fabricated galvanised steel items ( zinc 610gms / sqm ) , like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, tea off, guarding channels, back clamp, dts structure etc made of gs channels , gs angle , gs flats ( 50x8mm ) of given sizes for over head structures as per technical specification, approved drawings and scope of work. 55 gs nuts, bolts and washers as per technical specification, approved drawings and scope of work. 56 g.i. wire 6 swg 57 g.i. wire 8 swg 58 eye bolt 59 g.i. wire no. 16 swg for binding 60 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 61 11 kv pin insulator polymer type as per ts 62 11 kv polymer disc insulators45 knt&c type 63 11 kv disc fitting t & c type 64 pg clamp for rabbit 65 aluminium binding wire 6 swg 66 jointing sleave acsr weasel 67 11 kv danger board 68 g.i. barbed wire 69 earthing coil connected with nutbolt using bentonite powder 70 stay complete ( gi stay rod 16x1800 mm 1 nos , eye bolt 1 nos, anchor plate 1 nos, turn buckle 1 nos, hellically formed end fitting, square washer and thimble, nuts bolt & washers ref drg rec / rdss / gen / 09 71 ht guy insulator 72 gi stay wire 7 / 10 swg 73 ht stay clamp as per approved drawing 11 kv 74 11 kv number plate 75 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 76 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 25 kva ( complete work in all respect ) 77 25 kva , 11 / 0.433 kv t / f ( level 1 self protected aluminium wound type ) 78 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 79 stone pad ( 300x300x75mm ) 80 pre fabricated galvanised steel items ( zinc 610gms / sqm ) , like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, tea off, guarding channels, back clamp, dts structure etc made of gs channels , gs angle , gs flats ( 50x8mm ) of given sizes for over head structures as per technical specification, approved drawings and scope of work. 81 gs nuts, bolts and washers as per technical specification, approved drawings and scope of work. 82 11 kv polymer disc insulators45 knt&c type 83 11 kv disc fitting t & c type 84 11 kv pin insulator polymer type as per ts 85 11kv tpmo 86 11kv fuse set ( drop out ) 87 9 kv la , 5 ka ( distribution class ) 88 lt distribution box withmccb and ami metering ( smart meter compitable with system ) equipmen . ( smc type ) for 25kva ( drg no. rec / rdss / dtr / ss / 24 ) 89 lt xlpe cable 4x16 sq mm 90 g.i. barbed wire 91 acsr rabbit conductor jumpering works 92 stay complete ( gi stay rod 16x1800 mm 1 nos , eye bolt 1 nos, anchor plate 1 nos, turn buckle 1 nos, hellically formed end fitting, square washer and thimble, nuts bolt & washers ref drg rec / rdss / gen / 09 93 ht guy insulator 94 gi stay wire 7 / 10 swg 95 ht stay clamp as per approved drawing 11 kv 96 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 97 gi flat 25x3 for earthing 98 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 99 erection, testingand commissioning of new lt line with ab cable ( complete work in all respect ) 100 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 101 stone pad ( 300x300x75mm ) 102 aerial bunched xlpe cable 1x25 ( ph ) + 1x16 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 103 aerial bunched xlpe cable 3x50 ( ph ) + 1x35 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 104 pole clamps with with i hook for laying abc 105 dead end clamp ( insulated ) 106 suspension clamps ( insulated ) 107 end cap for ab cable 108 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 109 insulating piercing connector ( 16 95 sq.mm ) 110 1x25 mm2 un armoured xlpe insulated al. lt cable for energising the distribution boxes. 111 single phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with clamps ( 40x3 mm ) and nut & bolts 112 three phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with clamps ( 40x3 mm ) and nut & bolts 113 earthing coil connected with nutbolt using bentonite powder 114 stay complete ( gi stay rod 16x1800 mm 1 nos , eye bolt 1 nos, anchor plate 1 nos, turn buckle 1 nos, hellically formed end fitting, square washer and thimble, nuts bolt & washers ref drg rec / rdss / gen / 09 115 lt guy insulator 116 gi stay wire 7 / 10 swg 117 lt stay clamp as per approved drawing 118 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 119 installation of sign board with as per ts and approved drawing 120 sign board as per ts and approved drawing...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

38786963 electrification of household in pe / ue habitations at banda & jhansizone under dvvnl, ( district banda, chitrakoot, hamirpur , mahoba, jhansi, jalaun & lalitpur ) of uttar pradesh state under revamped reforms based and results linked, distribution sector scheme 1 supply of items 2 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 3 stone pad ( 300x300x75mm ) 4 aerial bunched xlpe cable 3x50 ( ph ) + 1x35 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 5 aerial bunched xlpe cable 1x25 ( ph ) + 1x16 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 6 lt xlpe cable 4x16 sq mm 7 1x25 mm2 un armoured xlpe insulated al. lt cable for energising the distribution boxes. 8 acsr weasel conductor 9 acsr rabbit conductor jumpering works 10 aluminium binding wire 6 swg 11 11kv fuse set ( drop out ) 12 11kv tpmo 13 25 kva , 11 / 0.433 kv t / f ( level 1 self protected aluminium wound type ) 14 lt distribution box withmccb and ami metering ( smart meter compitable with system ) equipmen . ( smc type ) for 25kva ( drg no. rec / rdss / dtr / ss / 24 ) 15 9 kv la , 5 ka ( distribution class ) 16 earthing coil connected with nutbolt using bentonite powder 17 gi flat 25x3 for earthing 18 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 19 g.i. barbed wire 20 g.i. wire no. 16 swg for binding 21 g.i. wire 6 swg 22 g.i. wire 8 swg 23 11 kv disc fitting t & c type 24 11 kv polymer disc insulators45 knt&c type 25 11 kv pin insulator polymer type as per ts 26 dead end clamp ( insulated ) 27 end cap for ab cable 28 suspension clamps ( insulated ) 29 pole clamps with with i hook & nut & bolts for laying abc 30 insulating piercing connector ( 16 95 sq.mm ) 31 single phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with clamps ( 40x3 mm ) and nut & bolts 32 three phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with clamps ( 40x3 mm ) and nut & bolts 33 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 34 pg clamp for rabbit 35 gi stay wire 7 / 10 swg 36 ht guy insulator 37 lt guy insulator 38 stay complete ( gi stay rod 16x1800 mm 1 nos , eye bolt 1 nos, anchor plate 1 nos, turn buckle 1 nos, hellically formed end fitting, square washer and thimble, nuts bolt & washers ref drg rec / rdss / gen / 09 39 ht stay clamp as per approved drawing 11 kv 40 lt stay clamp as per approved drawing 41 pre fabricated galvanised steel items ( zinc 610gms / sqm ) , like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, tea off, guarding channels, back clamp, dts structure etc made of gs channels , gs angle , gs flats ( 50x8mm ) of given sizes for over head structures as per technical specification, approved drawings and scope of work. 42 gs nuts, bolts and washers as per technical specification, approved drawings and scope of work. 43 eye bolt 44 jointing sleave acsr weasel 45 11 kv danger board 46 11 kv number plate 47 sign board as per ts and approved drawing 48 erection part 49 survey , erection, testingand commissioning of 11 kv line ( complete work in all respect ) 50 route survey and pole spotting for 11 kv line 51 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 52 acsr weasel conductor 53 stone pad ( 300x300x75mm ) 54 pre fabricated galvanised steel items ( zinc 610gms / sqm ) , like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, tea off, guarding channels, back clamp, dts structure etc made of gs channels , gs angle , gs flats ( 50x8mm ) of given sizes for over head structures as per technical specification, approved drawings and scope of work. 55 gs nuts, bolts and washers as per technical specification, approved drawings and scope of work. 56 g.i. wire 6 swg 57 g.i. wire 8 swg 58 eye bolt 59 g.i. wire no. 16 swg for binding 60 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 61 11 kv pin insulator polymer type as per ts 62 11 kv polymer disc insulators45 knt&c type 63 11 kv disc fitting t & c type 64 pg clamp for rabbit 65 aluminium binding wire 6 swg 66 jointing sleave acsr weasel 67 11 kv danger board 68 g.i. barbed wire 69 earthing coil connected with nutbolt using bentonite powder 70 stay complete ( gi stay rod 16x1800 mm 1 nos , eye bolt 1 nos, anchor plate 1 nos, turn buckle 1 nos, hellically formed end fitting, square washer and thimble, nuts bolt & washers ref drg rec / rdss / gen / 09 71 ht guy insulator 72 gi stay wire 7 / 10 swg 73 ht stay clamp as per approved drawing 11 kv 74 11 kv number plate 75 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 76 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 25 kva ( complete work in all respect ) 77 25 kva , 11 / 0.433 kv t / f ( level 1 self protected aluminium wound type ) 78 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 79 stone pad ( 300x300x75mm ) 80 pre fabricated galvanised steel items ( zinc 610gms / sqm ) , like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, tea off, guarding channels, back clamp, dts structure etc made of gs channels , gs angle , gs flats ( 50x8mm ) of given sizes for over head structures as per technical specification, approved drawings and scope of work. 81 gs nuts, bolts and washers as per technical specification, approved drawings and scope of work. 82 11 kv polymer disc insulators45 knt&c type 83 11 kv disc fitting t & c type 84 11 kv pin insulator polymer type as per ts 85 11kv tpmo 86 11kv fuse set ( drop out ) 87 9 kv la , 5 ka ( distribution class ) 88 lt distribution box withmccb and ami metering ( smart meter compitable with system ) equipmen . ( smc type ) for 25kva ( drg no. rec / rdss / dtr / ss / 24 ) 89 lt xlpe cable 4x16 sq mm 90 g.i. barbed wire 91 acsr rabbit conductor jumpering works 92 stay complete ( gi stay rod 16x1800 mm 1 nos , eye bolt 1 nos, anchor plate 1 nos, turn buckle 1 nos, hellically formed end fitting, square washer and thimble, nuts bolt & washers ref drg rec / rdss / gen / 09 93 ht guy insulator 94 gi stay wire 7 / 10 swg 95 ht stay clamp as per approved drawing 11 kv 96 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 97 gi flat 25x3 for earthing 98 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 99 erection, testingand commissioning of new lt line with ab cable ( complete work in all respect ) 100 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 101 stone pad ( 300x300x75mm ) 102 aerial bunched xlpe cable 1x25 ( ph ) + 1x16 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 103 aerial bunched xlpe cable 3x50 ( ph ) + 1x35 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 104 pole clamps with with i hook for laying abc 105 dead end clamp ( insulated ) 106 suspension clamps ( insulated ) 107 end cap for ab cable 108 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 109 insulating piercing connector ( 16 95 sq.mm ) 110 1x25 mm2 un armoured xlpe insulated al. lt cable for energising the distribution boxes. 111 single phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with clamps ( 40x3 mm ) and nut & bolts 112 three phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with clamps ( 40x3 mm ) and nut & bolts 113 earthing coil connected with nutbolt using bentonite powder 114 stay complete ( gi stay rod 16x1800 mm 1 nos , eye bolt 1 nos, anchor plate 1 nos, turn buckle 1 nos, hellically formed end fitting, square washer and thimble, nuts bolt & washers ref drg rec / rdss / gen / 09 115 lt guy insulator 116 gi stay wire 7 / 10 swg 117 lt stay clamp as per approved drawing 118 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 119 installation of sign board with as per ts and approved drawing 120 sign board as per ts and approved drawing...

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

36506508 electrification / construction / extension of h.t. & l.t. line and different capacity of 11 / 0.4 kv s / s in the judikuiya / sishaniya / bargadhi andbargadwa saif. under the area of electricity distribution division tulsipur ( extension nagar nagar panchayat pachperwa. ( semi turnkey basis ) 1 loading, unloading and safe cartage of the following materials from electricity store centre, balrampurto the work site / dump site ( distance up to 70 km ) 2 st poles ( 11 mtr long ) 3 pcc poles ( 8.5 mtr long ) 4 100 kva t / f 5 abc banch cable size 3x95+1x70+1x35sq.mm. 6 a.c.s.r. weasel coductor 7 sub station base angle 8 11 kv x arm 9 11 x arm holding clamp 10 11 kv pin insulator 11 11 pin with nut 12 11 kv disc insulator 13 11 kv disc fitting 14 stay complete with stay wire & insulator. 15 earthing complete. 16 guarding wire 17 guarding channel with back clamp & i ball 18 fabrication & erection of single pole support for 11 kv & l.t. ( for proper hight ) line on 11 mtr. long st pole with fixing of necessary clamp & other accessories like 01 no. t off channel, clamp, danger board, nuts & bolt including electrode earthing, barbed wire, i hook clamp, i hook, stone pad etc. ( all the materials for fabrication shall be arranged by the contractor as per resspo norms. ) 19 fabrication & erection of double pole support for 11 kv & l.t. ( for proper hight ) line on 11 mtr. long st pole with fixing of necessary clamp & other accessories like 01 no. t off channel, clamp, danger board, nuts & bolt including electrode earthing, barbed wire, i hook clamp, i hook, stone pad etc. ( all the materials for fabrication shall be arranged by the contractor as per resspo norms. ) 20 erection of single pcc poles ( 8.5 mtr long ) for 11 kv / l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site 21 erection of sectional double pole sectional pcc pole ( 8.5 mtr long pcc pole ) alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site. 22 laying, stringing, sagging & binding of conductors of 11 kv in 3 phase, 3 wire line with jumpering ( where as required ) 23 earthing complete of pole as per resspo norms ( alongwith fitting of all accessories. ) . 24 erection and grouting of stay sets alongwith complete fittings. cement, sand & brick ballast provided by the contractor at his own cost. 25 grouting of poles with 1:4:8cc ratio of cement, sand & brick ballast, backfilling of pits with mud completely.all required materials provided by the contractor at his own cost. 26 construction of 11 / 0.4 kv s / s for 100 kvat / f with mounting and fitting of t / f on plinth / double pole with proper fitting of all acessories and connecting with all circuit including earthing of t / f fitting with all accessories. 27 laying, stringing & sagging of 3x95+1x70+1x35 sq.mm. abc cable up to proper sag. 28 cutting of tree branches for cleaning route of 11 kv / lt line at the work site 29 construction of masonry plinth of size 1.5x1.5x1.5 mtr. suitable for 250 to 400 kva capacity of t / f including fixing of rail / joist on plinth. all required materials provided by the contractor at his own cost. 30 pale fencing of transformers by welded ms squaremesh of size 25x25 m.m. fabricated on ms angles of size 50x50x6 mm and 40x40x5mm and ms strip having overall dimension & 2.75 metersx2.5 metersx2.5 meters complete with 01 no. gate with provision of hinges roller & locking arrangement, property grouted and painted with one coat of red oxide primer and two coats of enamel paint....

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

33488328 development of distribution infrastructure of package prayagraj 2 at kaushambi, fatehpur, and pratapgarh district of puvvnluttar pradeshunderrevamped reforms based and results linked, distribution sector scheme 1 conversion of existing lt lines on bare conductor to areal bunch xlpe cable 2 conversion of existing lt lines with bare conductor to ab xlpe cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 3 supply of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 4 galvanized stay set for lt line with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, 1 no. stay guy insulator, nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 5 conversion of existing lt lines using new earthing as per approved drawings, technical specifications and scope of work 6 supply of spike earthing made of 20mm x 2500 mm gi solid rod 7 supply of 8 swg gi wire for earthing and guarding 8 supply of following lt ab xlpe cable for conversion of existing lt bare conductor line with ab xlpe cable as required as per technical specification, approved drawings and scope of work: 9 supply of aerial bunchedxlpe cable 3 x 50 sqmm+1x35 sqmm. ( bare messenger wire ) +1x16 sqmm. 10 supply of aerial bunchedxlpe cable 3 x 70 sqmm.+1x50 sqmm. ( bare messenger wire ) +1x16 sqmm. 11 supply of aerial bunchedxlpe cable 3 x 95 sqmm.+1x70 sqmm. ( bare messenger wire ) + 1x16 sqmm. 12 supply of aerial bunchedxlpe cable 3 x 120 sqmm. + 1x95 sqmm. ( bare messenger wire ) +1x16 sqmm. 13 supply of pole mounted lt distribution box as per approved drawings, technical specifications and scope of work 14 supply of three phase smc distribution box with clamps 15 supply of single phase smc distribution box with clamps 16 supply of xlpe insulated al. cable for energisation of distribution box / kiosk as per approved drawings, technical specifications and scope of work 17 suppply of 2cx25 sqmm stranded unarmoured xlpe cable ( al conductor ) for chargingsingle phase db 18 suppply of 4cx35sqmm stranded unarmoured xlpe cable ( al conductor ) for chargingthreephase db 19 supply of stone pad ( 300x300x75 ) 20 supply of accessories for ab xlpe cable as per approved drawings, technical specifications and scope of work 21 stainless steel strap 22 hdg lt pole clamp with nut & bolt for laying abc 23 dead end clamp with i hook ( insulated ) 24 suspension clamp with i hook ( insulated ) 25 95 / 35 sqmm 70 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 26 120 / 50 sqmm 95 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 27 lt insulation piercing connector 120 50 sqmm 50 25 sqmm size ( for energizing distribution box ) 28 lt insulation piercing connector 120 50 sqmm 120 50 sqmm size ( for line to line jumpering ) 29 lt insulation piercing connector 16 25sqmmsize suitable for street light connection 30 pre insulated compression connectors size 16 sqmm suitable for ab xlpe cable 31 pre insulated compression connectors size 50 sqmm suitable for ab xlpe cable 32 pre insulated compression connectors size 70 sqmm suitable for ab xlpe cable 33 pre insulated compression connectors size 95 sqmm suitable for ab xlpe cable 34 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 35 heat shrinkable type end cap for ab xlpe cable 36 supply of new 11 kv lines : feeder segregation ( agriculture feeder ) 37 supply of support for 11 kv overhead line as per technical specification, approved drawings and scope of work 38 supply of 8.5m / 180 kgs pcc poles ( pcc pole as per state practice ) 39 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 40 supply for 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms transformer base channel, ms flats pole extension channel with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 41 supply of hot dip galvanized ms nuts, bolts with washers turn buckle for guarding as per technical specification, approved drawings and scope of work. 42 supply of pole accessories as per technical specification, approved drawing and scope of work 43 supply of 11 kv danger board 44 supply of stone pad 300x300x75 45 supply of barbed gi wire 12 swg 46 supply of stay set ( galvanized ) with 50x8 mm stay clamp, stay guy insulator ( 1 nos. ) , anchor plate ( 200x200x6 ) , nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 47 supply of insulator and hardware as per technical specification, approved drawings and scope of work. 48 supply of 11 kv45 kn polymer disc insulator along with suitable hardware fittings 49 supply of 11 kv 5 kn polymer pin insulators 50 supply of earthing arrangement as per technical specifications, approved drawings and scope of work. 51 supply of spike earthing 20mm x 2500 mmgi solid rod 52 supply of 8 swg gi wire for earthing and guarding 53 supply of 6 swg gi wire for earthing and guarding 54 supply of acsr conductors of following sizes with jointing sleeves, binding materials, pg clamps, bi metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work 55 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 56 supply of 11 kv, 600a, 3 ph, 3 pin type, vertical mounting type, gang operated, ab switch along with support insulators, base channel down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 57 supply of 11 kv lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 58 supply for 11 kv lineunder ground railway crossing with 2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) using 150mm dia gi pipes ( grade a for underground laying and grade b for pole support ) , outdoor heat shrinkable cable jointing kit, 11 kv lightening arrestor station class 10ka ( 6 nos. ) , lugs, 4 nos gi 3 meters long pipe earthing, 6 swg gi wires, cable markers, bi metallick clamps and jumpering etc as required as per technical specifications, drawings and scope of the work. 59 supply of 11 lv line underground highway crossing ensuring statutory clearancesas required as per technical specification, approved drawings and scope of work 60 supply of 11 kv lineforunder ground highway crossing by 2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) using 160 mm hdpe pipe at road crossing and 150mm dia gi pipes ( gradeb for pole support ) , outdoor heat shrinkable cable jointing kits, 11 kv lightening arrestor station class 10ka ( 6 nos. ) , lugs, 4 nos gi 3 meters long pipe earthing, 6 swg gi wires, 7 / 20 gi wire, cable markers, bi metallick clamps and jumpering etc as required as per technical specifications, drawings and scope of the work. 61 supply of 12 kv 3ph indoor type switch gear and 11 kv xlpe cable as per technical specifications, approved drawings and scope of works: 62 supply of indoor type 12 kv 3 ph 1250 a vcb with control and protection system for out going feeder consisting ofct, a meter, volt meter, relays, energy meter ( tvm ) dlms compliant & accessories complete as per specifications for feeder breaker protection 63 11 kv 3x 185 sqmm xlpe armored power cable, aluminum stranded conductor, including their termination materials like indoor and outdoor termination kit, glands, lugs, tagging, cable path marker etc as required as per technical specifications, approved drawings and scope of the works. 64 supply for augmentation of lines 65 supply for augmentation of 33 kv line 66 supply for augmentation of 3 phase 33 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 67 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 68 supply new pre fabricated hot dip galvanized steel item, for augmentation of 33 kv line, like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 69 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 70 supply of pole accessories as per technical specification, approved drawing and scope of work 71 supply of 33 kv danger board 72 supply of gi barbed wire 12 swg 73 supply for augmentation of 3 phase 33 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material, aluminum tape and helical preformed fittings etc as required as per technical specification, approved drawings and scope of work. 74 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 75 supply of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 76 supply of 33 kv under ground cable as per technical specification, approved drawings and scope of work. 77 supply of 3cx300 sqmm 33 kv xlpe armored cable 78 supply of accessories for 33 kv3cx300 sqmm xlpe armored cable ( 2 nos including one spare ) like 160mm dia hdpe pipes for road crossing and 150 mm dia gi pipegrade b for pole support outdoor heat shrinkable cable jointing kits, lugs, cablepath markers, bi metallic clamps, and 7 / 20 gi wire as per technical specification, approved drawing and scope of work 79 supplyof new insulator and hardware for augmentation of33 kv line as per technical specification, approved drawings and scope of work 80 supply of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 81 supply of 33 kv 10 kn polymer pin insulators 82 supply of new earthing arrangement for augmentation of33 kv line as per technical specifications, approved drawings and scope of work. 83 8 swg gi coil 115 turns ( 1.85 kg ) 84 supply of new stay set ( galvanized ) for 33 kv line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate ( 300x300x8mm ) , nut bolts, 1 no. turn buckles, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 85 supply of new gi wire for earthing and guarding for augmentation of33 kv line as per technical specification, approved drawings and scope of work. 86 supply of 6 swg gi wire 87 supply of 8 swg gi wire 88 supply of conductor accessories as per technical specification, approved drawing and scope of work 89 supply of pg clamp for dog to dog conductor 90 supply of pg clamp for panther to panther conductor 91 supply for augmentation of 11 kv lines 92 supply for augmentation of 3 phase 11 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 93 supply of 8.5 meter long / 180 kg pcc poles ( pcc pole as per state practice ) 94 supply for augmentation of 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 95 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 96 supply of pole accessories as per technical specification, approved drawing and scope of work 97 supply of 11 kv danger board 98 stone pad ( 300x300x75mm ) 99 supply of gi barbed wire 12 swg 100 supply for augmentation of 3 phase 11 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. 101 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 102 supply of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 103 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 104 supply for augmentation of 3 phase 11 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 105 supply of 11 kv 45 kn polymer disc insulator along with suitable hardware fittings 106 supply of 11 kv 5 kn polymer pin insulators 107 supply for augmentation of 3 phase 11 kv line using new earthing arrangement as per technical specifications, approved drawings and scope of work. 108 supply of gi earthing spike made of 20x2500mm solid rod 109 supply for augmentation of 3 phase 11 kv line using new stay set ( galvanized ) with 50x8 mm stay clamp, guy insulator, anchor plate ( 200x200x6mm ) , nut bolts, 1 no turn buckles, 1.8 m long 16 mm diameter solid gi stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 110 supply for augmentation of 3 phase 11 kv line using new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 111 supply of 6 swg gi wire 112 supply of 8 swg gi wire 113 supply of conductor accessories as per technical specification, approved drawing and scope of work 114 supply of pg clamp for weasel to weasel conductor 115 supply of pg clamp for dog to dog conductor 116 supply of pg clamp for rabbit to rabbit conductor 117 installation of dt capacitor 118 supply of dt capacitor with fitting as per technical specification, approved drawing and scope of work 119 supply of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 120 supply of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 121 supply of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 122 supply of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 123 erection part 124 erection for conversion of existing lt lines on bare conductor to aerial bunch xlpe cable 125 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil of following pole as per scope of work, approved drawings and specifications: 126 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 127 erection of following types of poles for lt overhead line with stone pad, pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 128 erection of 8.5 m / 180 kgs pcc poles with base stone pad as required ( state practices of pcc pole and stone pad to be used ) 129 excavation of lt stay pit in following type of soils, as per scope of work, approved drawings and specifications: 130 normal soil 131 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 132 removal of existing lt bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched xlpe cable, fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, pre insulated compression connectors, 16 mm dia ms nuts & bolts, pole clamps, stainless steel strap, single and three phase pole mounted distribution board, energisation of distribution box through 2cx25 sqmm and 4cx35 sq.mm xlpe cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: 133 erection of aerial bunched xlpe cable3 x 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm 134 erection of aerial bunched xlpe cable 3 x 70 sqmm +1x50 sqmm ( bare messenger cum neutral ) +1x16 sqmm 135 erection of aerial bunched xlpe cable 3 x 95 sqmm +1x70 sqmm ( bare messenger cum neutral ) + 1x16 sqmm 136 erection of aerial bunched xlpe cable 3 x 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm 137 erection, testing & commissioning of earthing by inserting gi earthing spike made of 20mm solid rod as per approved drawings, scope of work and technical specifications 138 erection of 8 swg gi wire for earthing by providing gi nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications 139 erection, testing and commissioning of new 11 kv lines: feeder segregation ( agriculture feeder ) 140 survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of project manager 141 excavation of pole pit ( of depth 1 / 6th of pole length ) in normal soil for following type pole as per scope of work, approved drawings and specifications: 142 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 143 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 144 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , painting by red oxide & aluminum paint to stp poles including paint, numberingof poleby paint including cement concrete foundation using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 145 erection of 8.5 m / 180 kgs pcc poles with base pad including cement concreting, ( state practices of pcc pole, stone to be used ) 146 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.5 cmt + 0.014 cmt ( muffing ) 147 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washersas per technical specification, approved drawings and scope of work. 148 earthing arrangement as per technical specifications, approved drawings and scope of work. 149 erection, testing & commissioning of spike earthing 20mm x 2500mm solid rod 150 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 151 normal soil 152 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 1 nos. ) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 153 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 154 erection of 5 kn 11 kv polymer pin insulator 155 erection of 45 kn 11 kv polymer disc insulator with strain hardware 156 laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 157 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 158 erection, testing and commissioning of vertical type 11 kvab switch along with support insulators, base channel, down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 159 erection, testing & commissioning of 11 kv line for under ground railway crossing by2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) , using 150mm dia gi pipes, outdoor heat shrinkable cable jointing kits, lugs, 4 nosgi 3 meters long earthing pipe, 6 swg gi wires, cable markers, clamps, jumpering and 11 kv station type lightening arrestors ( 6 nos. ) , etc as required as per technical specifications, approved drawings and scope of he work. 160 erection, testing & commissioning of 11 kv line for under ground highway crossing by2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) , using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, 4 nosgi 3 meters long earthing pipe, 6 swg gi wires, 7 / 20 gi wire, cable markers, clamps, jumpering, 11 kv station type lightening arrestors ( 6 nos. ) , etc as required as per technical specifications, approved drawings and scope of he work. 161 erection of 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor typevacuum circuit breaker with adopter panel for out going feeder by leveling, alignment and welding on existing cable trench in control room. testing & commissioning of indoor vcb panel including 3 nos indoor type current transformer, a meter, volt meter, relay & accessories protection as per approved drawings, technical specifications and scope of the work.: 162 providing and fixing of sign board includingmaterial and its fabrication , painting , writing , logo and scheme name etc as per rdss guidelines and t.s 163 laying, erection, termination using indoor & outdoor termination kit, 11kv 3x 185 sqmm xlpearmored power cablesas per technical specifications, approved drawings and scope of works. : 164 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 165 erection of 6 swg gi wire 166 erection of 8 swg gi wire 167 extension of control room of 33 / 11 kv substation to accommodate vcb for new 11 kv feeders as per technical specification, approved drawing and scope of work. 168 design, engineering construction of control room building extension 300 sq feet including cost ofall materials, t&p and labour, etc. as per technical specification and approved drawing as per direction of employer 169 shifting of following distribution transformer along with fixture including dismantling , shifting and erection from one location to another location as per approved survey. 170 single phase transformer 171 three phase transformer 172 erection for augmentation of lines 173 erection for augmentation of 33 kv line 174 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 175 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 176 erection of following types of additional poles matching with existing line supports by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminum paint including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 177 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.5 cmt + 0.014 cmt ( muffing ) 178 excavation of stay pit for 33 kv stay in following type of soils, as per scope of work, approved drawings and specifications: 179 normal soil 180 erection of complete stay set with gi stay wire ( 7x4.00 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 181 erection, testing and commissioning of 33 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 182 erection of 33 kv 10 kn pin insulator with gi pin 183 erection of 33 kv 70 kn disc insulator with strain hardware ( set of 3, 11 kv disc insulators ) 184 erection, testing & commissioning of new pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. 185 dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store and laying out & stringing of new acsr conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. 186 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 187 stringing of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 188 erection, testing & commissioning of 33 kvunder ground cable by2 nos ( including one spare ) 3cx300 sqmm xlpe armored cable, using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering, etc as required as per technical specifications, approved drawings and scope of he work. 189 erection for augmentation of 3 phase 33 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 190 erection of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 191 erection of 33 kv 10 kn polymer pin insulators 192 erection, testing & commissioning of earthing as per technical specifications, approved drawings and scope of work. 193 8 swg gi coil 115 turns ( 1.85 kg ) 194 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 195 erection of 6 swg gi wire 196 erection of 8 swg gi wire 197 erection for augmentation of 11 kv lines 198 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 199 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 200 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 201 erection of 8.5 m / 180 kgs pcc poles withbase stone pad ( state practices of pcc pole and base plate / stone to be used ) 202 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 203 normal soil 204 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 205 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 206 erection of 11 kv pin insulator with gi pin 207 erection of 11 kv disc insulator with strain hardware 208 dismantling of existing overhead line conductor & fittings and depositing to employers store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 209 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 210 stringing of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 211 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 212 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and hdg ms nuts, bolts & washers as per technical specification, approved drawings and scope of work. 213 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 214 erection of 5 kn 11 kv polymer pin insulator 215 erection of 45 kn 11 kv polymer disc insulator with strain hardware 216 earthingand guarding arrangement as per technical specifications, approved drawings and scope of work. 217 erection, testing & commissioning of spike earthing 20mm solid rod 218 erection of 8 swg gi wire for earthing and guarding 219 erection of 6 swg gi wire for earthing and guarding 220 erection of dt capacitor 221 erection, testing & commissioning offollowing 440 volt lt shunt capacitor including mounting structure and accessories as required as per technical specifications, approved drawings and scope of work. 222 erection of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 223 erection of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 224 erection of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 225 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 226 discount offered in % 227 words final quoted price after discount...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

33488283 development of distribution infrastructure of packageprayagraj 1 at prayagraj district of puvvnluttar pradeshunderrevamped reforms based and results linked, distribution sector scheme 1 supply of consumer service cable 2 supply of armored service cable for consumer service connection with accessories as per technical specifications, scope of works and approved drawings 3 supply of single phase armored al cable size 2cx 6 sq mm 4 supply of three phase armored al cable size 4cx 16 sq mm 5 supply of 10 swg gi wire 6 supply of 8 swg gi wire 7 supply of gi pipe / m.s angle along with nails / clamps / proper binding e.t.c. as per rec std. 8 conversion of existing lt lines on bare conductor to areal bunch xlpe cable 9 conversion of existing lt lines with bare conductor to ab xlpe cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 10 supply of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 11 galvanized stay set for lt line with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, 1 no. stay guy insulator, nut bolts, 1 no. turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 12 conversion of existing lt lines using new earthing as per approved drawings, technical specifications and scope of work 13 supply of spike earthing made of 20mm x 2500 mm gi solid rod 14 supply of 8 swg gi wire for earthing and guarding 15 supply of following lt ab xlpe cable for conversion of existing lt bare conductor line with ab xlpe cable as required as per technical specification, approved drawings and scope of work: 16 supply of aerial bunchedxlpe cable 3 x 50 sqmm+1x35 sqmm. ( bare messenger wire ) +1x16 sqmm. 17 supply of aerial bunchedxlpe cable 3 x 70 sqmm.+1x50 sqmm. ( bare messenger wire ) +1x16 sqmm. 18 supply of aerial bunchedxlpe cable 3 x 95 sqmm.+1x70 sqmm. ( bare messenger wire ) + 1x16 sqmm. 19 supply of aerial bunchedxlpe cable 3 x 120 sqmm. + 1x95 sqmm. ( bare messenger wire ) +1x16 sqmm. 20 supply of pole mounted lt distribution box as per approved drawings, technical specifications and scope of work 21 supply of three phase smc distribution box with clamps 22 supply of single phase smc distribution box with clamps 23 supply of xlpe insulated al. cable for energisation of distribution box / kiosk as per approved drawings, technical specifications and scope of work 24 suppply of 2cx25 sqmm stranded unarmoured cable ( al conductor ) for chargingsingle phase db 25 suppply of 4cx35sqmm stranded unarmoured cable ( al conductor ) for chargingthreephase db 26 supply of stone pad ( 300x300x75 ) 27 supply of accessories for ab xlpe cable as per approved drawings, technical specifications and scope of work 28 stainless steel strap 29 hdg lt pole clamp with nut & bolt for laying abc 30 dead end clamp with i hook ( insulated ) 31 suspension clamp with i hook ( insulated ) 32 95 / 35 sqmm 70 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 33 120 / 50 sqmm 95 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 34 lt insulation piercing connector 120 50 sqmm 50 25 sqmm size ( for energizing distribution box ) 35 lt insulation piercing connector 120 50 sqmm 120 50 sqmm size ( for line to line jumpering ) 36 lt insulation piercing connector 16 25sqmmsize suitable for street light connection 37 pre insulated compression connectors size 16 sqmm suitable for ab xlpe cable 38 pre insulated compression connectors size 50 sqmm suitable for ab xlpe cable 39 pre insulated compression connectors size 70 sqmm suitable for ab xlpe cable 40 pre insulated compression connectors size 95 sqmm suitable for ab xlpe cable 41 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 42 heat shrinkable type end cap for ab xlpe cable 43 supply of new 11 kv lines : feeder segregation ( agriculture feeder ) 44 supply of support for 11 kv overhead line as per technical specification, approved drawings and scope of work 45 supply of 8.5m / 180 kgs pcc poles ( pcc pole as per state practice ) 46 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 47 supply for 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms transformer base channel, ms flats pole extension channel with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 48 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 49 supply of pole accessories as per technical specification, approved drawing and scope of work 50 supply of 11 kv danger board 51 supply of stone pad 300x300x75 52 supply of barbed gi wire 12 swg 53 supply of stay set ( galvanized ) with 50x8 mm stay clamp, stay guy insulator ( 1 nos. ) , anchor plate ( 200x200x6 ) , nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 54 supply of insulator and hardware as per technical specification, approved drawings and scope of work. 55 supply of 11 kv45 kn polymer disc insulator along with suitable hardware fittings 56 supply of 11 kv 5 kn polymer with pin insulators 57 supply of earthing arrangement as per technical specifications, approved drawings and scope of work. 58 supply of spike earthing 20mm x 2500 mm gi solidrod 59 supply of 8 swg gi wire for earthing and guarding 60 supply of 6 swg gi wire for earthing and guarding 61 supply of acsr conductors of following sizes with jointing sleeves, binding materials, pg clamps, bi metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work 62 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 63 supply of 11 kv, 600a, 3 ph, 3 pin type, vertical mounting type, gang operated, ab switch along with support insulators, base channel down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 64 supply of 11 kv lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 65 supply for 11 kv lineunder ground railway crossing with 2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) using 150mm dia gi pipes ( grade a for underground laying and grade b for pole support ) , outdoor heat shrinkable cable jointing kit, 11 kv lightening arrestor station class 10ka ( 6 nos. ) , lugs, 4 nos gi 3 meters long pipe earthing, 6 swg gi wires, cable markers, bi metallick clamps and jumpering etc as required as per technical specifications, drawings and scope of the work. 66 supply of 11 lv line underground highway crossing ensuring statutory clearancesas required as per technical specification, approved drawings and scope of work 67 supply of 11 kv lineforunder ground highway crossing by 2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) using 160 mm hdpe pipe at road crossing and 150mm dia gi pipes ( gradeb for pole support ) , outdoor heat shrinkable cable jointing kits, 11 kv lightening arrestor station class 10ka ( 6 nos. ) , lugs, 4 nos gi 3 meters long pipe earthing, 6 swg gi wires, 7 / 20 gi wire, cable markers, bi metallick clamps and jumpering etc as required as per technical specifications, drawings and scope of the work. 68 supply of 12 kv 3ph indoor type switch gear and 11 kv xlpe cable as per technical specifications, approved drawings and scope of works: 69 supply of indoor type 12 kv 3 ph 1250 a vcb with control and protection system for out going feeder consisting ofct, a meter, volt meter, relays, energy meter ( tvm ) dlms compliant & accessories complete as per specifications for feeder breaker 70 11 kv 3x 185 sqmm xlpe armored power cable, aluminum stranded conductor, including their termination materials like indoor and outdoor termination kit, glands, lugs, tagging, cable path marker etc as required as per technical specifications, approved drawings and scope of the works. 71 supply for augmentation of lines 72 supply for augmentation of 33 kv line 73 supply for augmentation of 3 phase 33 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 74 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 75 supply new pre fabricated hot dip galvanized steel item, for augmentation of 33 kv line, like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 76 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 77 supply of pole accessories as per technical specification, approved drawing and scope of work 78 supply of 33 kv danger board 79 supply of gi barbed wire 12 swg 80 supply for augmentation of 3 phase 33 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material, aluminum tape and helical preformed fittings etc as required as per technical specification, approved drawings and scope of work. 81 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 82 supply of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 83 supply of 33 kv under ground cable as per technical specification, approved drawings and scope of work. 84 supply of 3cx300 sqmm 33 kv xlpe armored cable 85 supply of 33 kv3cx300 sqmm xlpe armored cable ( 2 nos including one spare ) accessories like 160mm dia hdpe pipes for road crossing and 150 mm dia gi pipegrade b for pole support outdoor heat shrinkable cable jointing kits, lugs, cablepath markers, bi metallic clamps, 7 / 20 gi wire as per technical specification, approved drawing and scope of work 86 supplyof new insulator and hardware for augmentation of33 kv line as per technical specification, approved drawings and scope of work 87 supply of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 88 supply of 33 kv 10 kn polymer pin insulators 89 supply of new earthing arrangement for augmentation of33 kv line as per technical specifications, approved drawings and scope of work. 90 8 swg gi coil 115 turns ( 1.85 kg ) 91 supply of new stay set ( galvanized ) for 33 kv line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate ( 300x300x8mm ) , nut bolts, 1 no. turn buckles, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 92 supply of new gi wire for earthing and guarding for augmentation of33 kv line as per technical specification, approved drawings and scope of work. 93 supply of 6 swg gi wire 94 supply of 8 swg gi wire 95 supply of conductor accessories as per technical specification, approved drawing and scope of work 96 supply of pg clamp for dog to dog conductor 97 supply of pg clamp for panther to panther conductor 98 supply for augmentation of 11 kv lines 99 supply for augmentation of 3 phase 11 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 100 supply of 8.5 meter long / 180 kg pcc poles ( pcc pole as per state practice ) 101 supply for augmentation of 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 102 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 103 supply of pole accessories as per technical specification, approved drawing and scope of work 104 supply of 11 kv danger board 105 stone pad ( 300x300x75mm ) 106 supply of gi barbed wire 12 swg 107 supply for augmentation of 3 phase 11 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. 108 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 109 supply of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 110 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 111 supply for augmentation of 3 phase 11 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 112 supply of 11 kv 45 kn polymer disc insulator along with suitable hardware fittings 113 supply of 11 kv 5 kn polymer pin insulators 114 supply for augmentation of 3 phase 11 kv line using new earthing arrangement as per technical specifications, approved drawings and scope of work. 115 supply of gi earthing spike made of 20x2500mmsolid rod 116 supply for augmentation of 3 phase 11 kv line using new stay set ( galvanized ) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate ( 200x200x6mm ) , nut bolts, 1no. turn buckles, 1.8 m long 16 mm diameter solid gi stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 117 supply for augmentation of 3 phase 11 kv line using new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 118 supply of 6 swg gi wire 119 supply of 8 swg gi wire 120 supply of conductor accessories as per technical specification, approved drawing and scope of work 121 supply of pg clamp for weasel to weasel conductor 122 supply of pg clamp for dog to dog conductor 123 supply of pg clamp for rabbit to rabbit conductor 124 installation of dt capacitor 125 supply of dt capacitor with fitting as per technical specification, approved drawing and scope of work 126 supply of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 127 supply of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 128 supply of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 129 supply of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 130 supply of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 131 supply of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 132 erection part 133 installation of consumer service cable 134 installation of armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings 135 installation of single phase armored al cable size 2cx 6 sq mm 136 installation of three phase armored al cable size 4cx 16 sq mm 137 gi wire 8 swg 138 gi wire 10 swg 139 installation of gi pipe / m.s angle along with nails / clamps / proper binding e.t.c. as per r.e.c std. 140 erection for conversion of existing lt lines on bare conductor to aerial bunch xlpe cable 141 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil of following pole as per scope of work, approved drawings and specifications: 142 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 143 erection of following types of poles for lt overhead line with stone pad, pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 144 erection of 8.5 m / 180 kgs pcc poles with base stone pad as required ( state practices of pcc pole and stone pad to be used ) 145 excavation of lt stay pit in following type of soils, as per scope of work, approved drawings and specifications: 146 normal soil 147 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 1 no. ) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 148 removal of existing lt bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched xlpe cable, fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, pre insulated compression connectors, 16 mm dia ms nuts & bolts, pole clamps, stainless steel strap, single and three phase pole mounted distribution board, energisation of distribution box through 2cx25 sqmm and 4cx35 sq.mm xlpe cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: 149 erection of aerial bunched xlpe cable3 x 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm 150 erection of aerial bunched xlpe cable 3 x 70 sqmm +1x50 sqmm ( bare messenger cum neutral ) +1x16 sqmm 151 erection of aerial bunched xlpe cable 3 x 95 sqmm +1x70 sqmm ( bare messenger cum neutral ) + 1x16 sqmm 152 erection of aerial bunched xlpe cable 3 x 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm 153 erection, testing & commissioning of earthing by inserting gi earthing spike made of 20mm solid rod as per approved drawings, scope of work and technical specifications 154 erection of 8 swg gi wire for earthing by providing gi nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications 155 erection, testing and commissioning of new 11 kv lines: feeder segregation ( agriculture feeder ) 156 survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of project manager 157 excavation of pole pit ( of depth 1 / 6th of pole length ) in normal soil for following type pole as per scope of work, approved drawings and specifications: 158 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 159 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 160 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminum paint to stp poles including paint, numberingof poleby paint including cement concrete foundation using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 161 erection of 8.5 m / 180 kgs pcc poles with base pad including cement concreting, ( state practices of pcc pole, stone to be used ) 162 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.5 cmt + 0.014 cmt ( muffing ) 163 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washersas per technical specification, approved drawings and scope of work. 164 earthing arrangement as per technical specifications, approved drawings and scope of work. 165 erection, testing & commissioning of spike earthing 20mm x 2500mm gi solid rod 166 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 167 normal soil 168 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 169 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 170 erection of 5 kn 11 kv polymer with pin insulator 171 erection of 45 kn 11 kv polymer disc insulator with strain hardware 172 laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 173 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 174 erection, testing and commissioning of vertical type 11 kvab switch along with support insulators, base channel, down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 175 erection, testing & commissioning of 11 kv line for under ground railway crossing by2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) , using 150mm dia gi pipes, outdoor heat shrinkable cable jointing kits, lugs, 4 nosgi 3 meters long earthing pipe, 6 swg gi wires, cable markers, clamps, jumpering and 11 kv station type lightening arrestors ( 6 nos. ) , etc as required as per technical specifications, approved drawings and scope of he work. 176 erection, testing & commissioning of 11 kv line for under ground highway crossing by2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) , using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, 4 nosgi 3 meters long earthing pipe, 6 swg gi wires, 7 / 20 gi wire, cable markers, clamps, jumpering, 11 kv station type lightening arrestors ( 6 nos. ) , etc as required as per technical specifications, approved drawings and scope of he work. 177 erection of 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor typevacuum circuit breaker with adopter panel for out going feeder by leveling, alignment and welding on existing cable trench in control room. testing & commissioning of indoor vcb panel including 3 nos indoor type current transformer, a meter, volt meter, relay & accessories protection as per approved drawings, technical specifications and scope of the work.: 178 providing and fixing of sign board includingmaterial and its fabrication , painting , writing , logo and scheme etc as per rdss guidelines and t.s 179 laying, erection, termination using indoor & outdoor termination kit, 11kv 3x 185 sqmm xlpearmored power cablesas per technical specifications, approved drawings and scope of works. : 180 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 181 erection of 6 swg gi wire 182 erection of 8 swg gi wire 183 extension of control room of 33 / 11 kv substation to accommodate vcb for new 11 kv feeders as per technical specification, approved drawing and scope of work. 184 design, engineering construction of control room building extension 300 sq feet including cost ofall materials, t&p and labour, etc. as per technical specification and approved drawing as per direction of employer 185 shifting of following distribution transformer along with fixture including dismantling , shifting and erection from one location to another location as per approved survey. 186 single phase transformer 187 three phase transformer 188 erection for augmentation of lines 189 erection for augmentation of 33 kv line 190 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 191 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 192 erection of following types of additional poles matching with existing line supports by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminum paint including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 193 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.5 cmt + 0.014 cmt ( muffing ) 194 excavation of stay pit for 33 kv stay in following type of soils, as per scope of work, approved drawings and specifications: 195 normal soil 196 erection of complete stay set with gi stay wire ( 7x4.00 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 197 erection, testing and commissioning of 33 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 198 erection of 33 kv 10 kn pin insulator with gi pin 199 erection of 33 kv 70 kn disc insulator with strain hardware ( set of 3, 11 kv disc insulators ) 200 erection, testing & commissioning of new pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. 201 dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store and laying out & stringing of new acsr conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. 202 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 203 stringing of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 204 erection, testing & commissioning of 33 kvunder ground cable by2 nos ( including one spare ) 3cx300 sqmm xlpe armored cable, using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering, 7 / 20 gi wire etc as required as per technical specifications, approved drawings and scope of he work. 205 erection for augmentation of 3 phase 33 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 206 erection of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 207 erection of 33 kv 10 kn polymer pin insulators 208 erection, testing & commissioning of earthing as per technical specifications, approved drawings and scope of work. 209 8 swg gi coil 115 turns ( 1.85 kg ) 210 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 211 erection of 6 swg gi wire 212 erection of 8 swg gi wire 213 erection for augmentation of 11 kv lines 214 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 215 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 216 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 217 erection of 8.5 m / 180 kgs pcc poles withbase stone pad ( state practices of pcc pole and base plate / stone to be used ) 218 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 219 normal soil 220 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 221 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 222 erection of 11 kv pin insulator with gi pin 223 erection of 11 kv disc insulator with strain hardware 224 dismantling of existing overhead line conductor & fittings and depositing to employers store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 225 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 226 stringing of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 227 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 228 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and hdg ms nuts, bolts & washers as per technical specification, approved drawings and scope of work. 229 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 230 erection of 5 kn 11 kv polymer pin insulator 231 erection of 45 kn 11 kv polymer disc insulator with strain hardware 232 earthingand guarding arrangement as per technical specifications, approved drawings and scope of work. 233 erection, testing & commissioning of spike earthing 20mm solid rod 234 erection of 8 swg gi wire for earthing and guarding 235 erection of 6 swg gi wire for earthing and guarding 236 erection of dt capacitor 237 erection, testing & commissioning offollowing 440 volt lt shunt capacitor including mounting structure and accessories as required as per technical specifications, approved drawings and scope of work. 238 erection of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 239 erection of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 240 erection of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 241 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 242 erection of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 243 erection of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 244 discount offered in % 245 words final quoted price after discount...

Madhyanchal Vidut Vitran Nigam Limited - Uttar Pradesh

33384460 development of distribution infrastructure at [ raebareilly, sitapur, unnao ] district of uttar pradesh under revamped reforms based and results linked, distribution sector scheme 1 lt line with xlpe armoured cable in high loss area 2 route survey and pole spotting and mapping ( as per employer requirement of sbd ) 3 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 4 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 5 13 m long steel tubular poles with welded steel base plate of designation 410 sp 72 6 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 7 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 8 stone pad for supports as per scope of works & drawing ( 300x300x75 mm ) 9 red oxide paint as per ts 10 aluminium paint as per ts 11 1.1 kv single core 25sqmm xlpe armoured cable ( 1cx25 sqmm ) 12 1.1 kv single core 50sqmm xlpe armoured cable ( 1cx50 sqmm ) 13 1.1 kv single core 95sqmm xlpe armoured cable ( 1cx95 sqmm ) 14 1.1 kv single core 120sqmm xlpe armoured cable ( 1cx120 sqmm ) 15 lt cross arm arrangement angel ( 50x50x6mm ) ( 50x8mm ) ( weight 9.41 kg ) with nuts and bolts 16 lt cross arm arrangement angel ( 75x75x8mm ) ( 65x8mm ) ( weight 18.6 kg ) with nuts and bolts 17 c clamp with nut & bolts 18 lt shakle insulator 19 distribution tie for shakle insulator 20 mid span joint 25sqmm 21 mid span joint 50sqmm 22 mid span joint 95sqmm 23 mid span joint 120sqmm 24 three phase 20swg crca ms sheet by deep drawn / sheet bending processpole top distribution box with calmps ( 50x6 mm ) and nut & bolts and lugs suitable for 25 sqmm armoured cable 25 three single phase 20swg crca ms sheet by deep drawn / sheet bending processpole top distribution box with calmps ( 50x6 mm ) and nut & bolts and lugs suitable for 50 sqmm armoured cable 26 three phase 20swg crca ms sheet by deep drawn / sheet bending processpole top distribution box with calmps ( 50x6 mm ) and nut & bolts and lugs suitable for 95 sqmm armoured cable 27 three phase 20swg crca ms sheet by deep drawn / sheet bending processpole top distribution box with calmps ( 50x6 mm ) and nut & bolts and lugs suitable for 120 sqmm armoured cable 28 1x2.5 sqmm pvc insulated aluminium cable for energising the street light. 29 5a, 240 v, isi marked piano type switch 30 earthing of pole by earthing coil ( with salt & charcoal ) 31 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 32 removal of existing material and shifting to mvvnl store 33 armoured cabling in consumer service connection 34 single phase ( 2cx4 sqmm ) pvc armoured service cable 35 single phase ( 2cx6 sqmm ) pvc armoured service cable 36 three phase ( 4cx16 sqmm ) pvc armoured service cable 37 supporting gi wire 10 swg ( as per site requirements ) 38 20 swg gi wire for binding 39 arrangement for holding the service cable at pole ( ms flat 50x8 mm, 3.0 kg ) with nuts and bolts 40 arrangement for holding the service cable at pole ( ms flat 75x8 mm, 4.6 kg ) with nuts and bolts 41 ms angle 50x50x5 mm for holding the service cable at consumer premises ( length 1000 mm ) 42 polycarbonated box for single phase consumer 43 polycarbonated box for three phase consumer 44 removal of existing material and shifting to mvvnl store 45 replacement of bare conductors / damage cable with ab cables 46 route survey and pole spotting and mapping ( as per employer requirement of sbd ) 47 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 48 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 49 13 m long steel tubular poles with welded steel base plate of designation 410 sp 72 50 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 51 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 52 stone pad for supports as per scope of works & drawing ( 300x300x75 mm ) 53 red oxide paint as per ts 54 aluminium paint as per ts 55 single phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with calmps ( 40x3 mm ) and nut & bolts 56 three phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with calmps ( 40x3 mm ) and nut & bolts 57 2cx25 sqmm xlpe aluminium conductor cable for single phase db incomer 58 4cx35 sqmm xlpe aluminium conductor cable for three phase db incomer 59 earthing of pole by earthing coil ( with salt & charcoal ) 60 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 61 aerial bunched xlpe cable 1x25 ( ph ) + 1x25 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 62 aerial bunched xlpe cable 3x50 ( ph ) + 1x35 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 63 aerial bunched xlpe cable 3x95 ( ph ) + 1x70 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 64 aerial bunched xlpe cable 3x120 ( ph ) + 1x95 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 65 aerial bunched xlpe cable 3x150 ( ph ) + 1x120 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 66 lt pole clamp ( 50x8mm ) ( 2.56 kg ) with nut and bolts 67 lt eye hook 68 suspension clamp 69 dead end clamp 70 insulation piercing connectors / connector type i ( ab cable to ab cable ) 71 insulation piercing connectors type ii ( ab cable to service cable ) 72 removal of existing material and shifting to mvvnl store 73 1x2.5 sqmm pvc al cable for energising the street light 74 end cap for ab cable 25 sqmm 75 end cap for ab cable 50 sqmm 76 end cap for ab cable 95 sqmm 77 end cap for ab cable 120 sqmm 78 end cap for ab cable 150 sqmm 79 pg clamp for messanger wire 80 provision of ab cables for extra circuits at existing dtr 81 overhead lt for extra circuit at existing dtr 82 route survey and pole spotting and mapping ( as per employer requirement of sbd ) 83 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 84 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 85 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 86 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 87 stone pad for supports as per scope of works & drawing ( 300x300x75 mm ) 88 red oxide paint as per ts 89 aluminium paint as per ts 90 single phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with calmps ( 40x3 mm ) and nut & bolts 91 three phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with calmps ( 40x3 mm ) and nut & bolts 92 2cx25 sqmm xlpe aluminium conductor cable for single phase db incomer 93 4cx35 sqmm xlpe aluminium conductor cable for three phase db incomer 94 earthing of pole by earthing coil ( with salt & charcoal ) 95 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 96 aerial bunched xlpe cable 1x25 ( ph ) + 1x25 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 97 aerial bunched xlpe cable 3x50 ( ph ) + 1x35 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 98 aerial bunched xlpe cable 3x95 ( ph ) + 1x70 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 99 aerial bunched xlpe cable 3x120 ( ph ) + 1x95 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 100 aerial bunched xlpe cable 3x150 ( ph ) + 1x120 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 101 lt pole clamp ( 50x8mm ) ( 2.56 kg ) with nut and bolts 102 lt eye hook 103 suspension clamp 104 dead end clamp 105 insulation piercing connectors / connector type i ( ab cable to ab cable ) 106 insulation piercing connectors type ii ( ab cable to service cable ) 107 1x2.5 sqmm pvc al cable for energising the street light 108 end cap for ab cable 25 sqmm 109 end cap for ab cable 50 sqmm 110 end cap for ab cable 95 sqmm 111 end cap for ab cable 120 sqmm 112 end cap for ab cable 150 sqmm 113 pg clamp for messanger wire 114 feeder segregation 115 overhead 11 kv new feeder 116 route survey and pole spotting and mapping ( as per employer requirement of sbd ) 117 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 118 9 meter long / 400 kg pcc poles ( pcc pole as per state practice ) 119 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 120 stone pad for supports as per scope of works & drawing ( 300x300x75 mm ) 121 stone pad for supports as per scope of works & drawing ( 450x450x75 mm ) 122 11kv v type cross arm ( m.s channel 75x40x6mm ) welded with ms angel ( 50x50x6 ) ( weight 10.37 kg ) with bolts and nuts 123 cross arm holding clamps ( ms flat 50x8 mm ) ( weight 1.33 kg ) with bolts and nuts 124 f bracket ms flat ( 50x8 mm ) ( weight 1.56 kg ) with nut and bolts 125 cut point top channel ( 100x50x6 mm ) of length 230 mm along with nut & bolts 126 cut point bottom channel ( 100x50x6 mm ) of length 1150 mm along with nut & bolts 127 tapping horizontal cross arm ( 100x50x6 mm ) of length 1020 mm along with calmps ( 50x8 ) and nut and bolts 128 tapping top channel ( 100x50x6 mm ) of length 256 mm along with calmps ( 50x8 ) and nut and bolts 129 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 130 horizontal belting angle ( angle 50x50x6 mm ) 2240 mm long with bolts and nuts 131 cross bracing angle ( angle 50x50x6 mm ) 2500 mm long with bolts and nuts 132 belting clamp top clamp ( flat 50x8 mm ) ( weight 1.4 kg ) with bolts and nuts 133 belting clamp bottom clamp ( flat 50x8 mm ) ( weight 1.5 kg ) with bolts and nuts 134 fish plate for jumpering 135 6 / 2.59 + 1 / 2.59 mm ( 30 sqmm al. area ) acsr weasel conductors 136 6 / 3.35 + 1 / 3.35 mm ( 50 sqmm al. area ) acsr rabbit conductors 137 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) acsr dog conductor 138 pg clamp for weasel conductor 139 pg clamp for rabbit conductor 140 pg clamp for dog conductor 141 distribution tie for pin insulator 142 armoured rod with ferrule 143 jointing sleeves aluminium 144 aluminium binding wire and tape 145 11 kv polymer disc insulator 45 kn ( b&s type ) along with suitable hardware fittings 146 11 kv polymer pin insulators 5 kn with nuts 147 earthing of pole by earthing coil ( with salt & charcoal ) 148 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 149 ms danger board with back calmps & nuts and boltsas per technical specification 150 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 151 numbering of pole of each support as per technical specification and scope of work 152 underground 11 kv new feeder 153 radar route survey for route profile of any utility cables, pipes etc. along the route as per ts and scope of work 154 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 155 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 156 red oxide paint as per ts 157 aluminium paint as per ts 158 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 159 horizontal belting angle ( angle 50x50x6 mm ) 2240 mm long with bolts and nuts 160 cross bracing angle ( angle 50x50x6 mm ) 2500 mm long with bolts and nuts 161 belting clamp top clamp ( flat 50x8 mm ) ( weight 1.4 kg ) with bolts and nuts 162 belting clamp bottom clamp ( flat 50x8 mm ) ( weight 1.5 kg ) with bolts and nuts 163 fish plate for jumpering 164 11 kv polymer pin insulators 5 kn with nuts 165 heat shrinkable jointing kit indoor for 11 kv 3c×185 sq.mm. xlpe cable 166 heat shrinkable jointing kit indoor for 11 kv 3c×120 sq.mm. xlpe cable 167 heat shrinkable jointing kit outdoor for 11 kv 3c×185 sq.mm. xlpe cable 168 heat shrinkable jointing kit outdoor for 11 kv 3c×120 sq.mm. xlpe cable 169 heat shrinkable cable jointing kit straight through for 11 kv 3c×185 sq.mm. xlpe cable 170 heat shrinkable cable jointing kit straight through for 11 kv 3c×120 sq.mm. xlpe cable 171 road restoration chages for pucca road crossing 172 road restoration chages for kucchha road crossing 173 supply and placing of pre cast concrete manhole chambers of size 900mm x 900mm internal dimension x 800mm height & 100mm wall thickness ( heavy duty ) with concrete cover of 100mm thickness in the specified locations in the trench. 174 supply & erection of 11 kv single core 95 sqmm xlpe aluminium cable for jumpering 175 supply & erection of aluminum lugs 185 sq.mm. 176 supply & erection of aluminum lugs 120 sq.mm. 177 supply & erection of cable warning tape 178 fixing of cable marker on cable route and inscription of feeder name and voltage on cable marker 179 supply of 11 kv 3c×120 sqmm xlpe cable 180 supply of 11 kv 3c×185 sqmm xlpe cable 181 earth digging, laying, termination / jointing, erection, testing & commissioning of 11 kv grade 3 core 120 / 185 sqmm xlpe power cable underground and backfilling with bricks, sands, excavated soil as per standard practise, levelling etc complete in all respect along with all accessories, earthing etc. and as per ts / approved drawing. 182 laying of 11 kv 3cx185 sq mm xlpe singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick, sand, stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. the ferruling of cable also include in this work ( all the material ) 183 laying of 11 kv 3x185 sq mm xlpe twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick, sand, stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. the ferruling of cable also include in this work ( all the material ) 184 laying of 11 kv 3cx120 sq mm xlpe singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick, sand, stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. the ferruling of cable also include in this work ( all the material 185 laying of 11 kv 3x120 sq mm xlpe twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick, sand, stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. the ferruling of cable also include in this work ( all the material ) 186 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 11 kv grade 3 core 120 / 185 sqmm xlpe power cable undergroundusing hdpe pipecomplete in all respect along with all accessories, earthing etc. and as per ts / approved drawing . 187 laying of 11 kv 3c×185 sqmm xlpe cable 188 laying of 11 kv 3×120 sqmm xlpe cable 189 pipe ( hdpe 160 mm dia ) for cable laying 190 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 11 kv grade 3 core 120 / 185 sqmm xlpe power cable undergroundwithout hdpe pipes in all respect along with all accessories, earthing etc. and as per ts / approved drawing . 191 laying of 11 kv 3c×185 sqmm xlpe cable 192 laying of 11 kv 3×120 sqmm xlpe cable 193 hoisting of following sizes of11 kv single cable on existing / erected double pole including gi pipe 3 mtr long 6 dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 194 testing & commissioning of 11 kv grade 3 core 185 sqmm xlpe power underground cable 195 testing & commissioning of 11 kv grade 3 core 120 sqmm xlpe power underground cable 196 earthing of pole by earthing coil ( with salt & charcoal ) 197 8 swg gi wire for pole, db earthing with gi nuts, bolts & washers 198 ms danger board with back calmps & nuts and boltsas per technical specification 199 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works & ts 200 numbering of pole of each support as per technical specification and scope of work 201 railway crossing 202 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 203 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 204 red oxide paint as per ts 205 aluminium paint as per ts 206 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 207 horizontal belting angle ( angle 50x50x6 mm ) 2240 mm long with bolts and nuts 208 cross bracing angle ( angle 50x50x6 mm ) 2500 mm long with bolts and nuts 209 belting clamp top clamp ( flat 50x8 mm ) ( weight 1.4 kg ) with bolts and nuts 210 belting clamp bottom clamp ( flat 50x8 mm ) ( weight 1.5 kg ) with bolts and nuts 211 fish plate for jumpering 212 11 kv polymer pin insulators 5 kn with nuts 213 9 kv, 10 ka station class la 214 supply of 11 kv 3c×185 sqmm xlpe cable 215 supply of 33 kv 3c×300 sqmm xlpe cable 216 heat shrinkable jointing kit outdoor for 11 kv 3c×185 sq.mm. xlpe cable 217 heat shrinkable jointing kit outdoor for 33 kv 3c×300 sq.mm. xlpe cable 218 hoisting of following sizes of11 kv single cable on existing / erected double pole including gi pipe 3 mtr long 6 dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 219 11 kv or 33 kv lineforunder ground railway crossing by 2 nos ( including one spare ) 3cx185 or 3cx300 sqmm xlpe armoured cable using 150mm dia gi pipes ( grade a for underground laying and grade b for pole support ) , outdoor heat shrinkable cable jointing kits, lugs, 4 nos gi 3 meters long pipe, earthing, 8 swg gi wires, cable markers, bi metallick clamps, jumpering , as required as per technical specifications, drawings and scope of the work. 220 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection of 11 kv grade 3 core 185 sqmm xlpe power cable underground as per ts / approved drawing . 221 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection of 33 kv grade 3 core 300 sqmm xlpe power cable underground as per ts / approved drawing . 222 digging of trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 11 kv xlpe cables including cost of bricks, sand, clamps etc. 223 digging of trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 33 kv xlpe cables including cost of bricks, sand, clamps etc. 224 g.i. pipe ( 6 dia. ) forlaying ug below the railway track ( minimum 3 meter ) by hdd method. 225 supply & erection of 11 kv single core 95 sqmm xlpe aluminium cable for jumpering 226 supply & erection of 33 kv single core 120 sqmm xlpe aluminium cable for jumpering 227 supply & erection of aluminum lugs 185 sq.mm. 228 supply & erection of aluminum lugs 300 sq.mm. 229 railway crossing documentation and approval fee etc. 230 testing & commissioning of 11 kv grade 3 core 185 sqmm xlpe power underground cable 231 testing & commissioning of 33 kv 3 core 300 sqmm xlpe power underground cable 232 earthing of pole by earthing coil ( with salt & charcoal ) 233 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 234 ms danger board with back calmps & nuts and boltsas per technical specification 235 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 236 numbering of pole of each support as per technical specification and scope of work 237 national highway crossing 238 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 239 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 240 red oxide paint as per ts 241 aluminium paint as per ts 242 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 243 horizontal belting angle ( angle 50x50x6 mm ) 2240 mm long with bolts and nuts 244 cross bracing angle ( angle 50x50x6 mm ) 2500 mm long with bolts and nuts 245 belting clamp top clamp ( flat 50x8 mm ) ( weight 1.4 kg ) with bolts and nuts 246 belting clamp bottom clamp ( flat 50x8 mm ) ( weight 1.5 kg ) with bolts and nuts 247 fish plate for jumpering 248 11 kv polymer pin insulators 5 kn with nuts 249 9 kv, 10 ka station class la 250 supply & erection of 11 kv single core 95 sqmm xlpe aluminium cable for jumpering 251 supply & erection of 33 kv single core 120 sqmm xlpe aluminium cable for jumpering 252 supply & erection of aluminum lugs 185 sq.mm. 253 supply & erection of aluminum lugs 300 sq.mm. 254 supply of 11 kv 3c×185 sqmm xlpe cable 255 supply of 33 kv 3c×300 sqmm xlpe cable 256 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 11 kv grade 3 core 185 or 300 sqmm xlpe power cable underground as per ts / approved drawing . 257 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection of 11 kv grade 3 core 185 sqmm xlpe power cable underground as per ts / approved drawing . 258 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection of 33 kv grade 3 core 300 sqmm xlpe power cable underground as per ts / approved drawing . 259 pipe ( hdpe 160 mm dia ) for cable laying at road crossings 260 heat shrinkable jointing kit outdoor for 11 kv 3c×185 sq.mm. xlpe cable 261 heat shrinkable jointing kit outdoor for 11 kv 3c×300 sq.mm. xlpe cable 262 hoisting of following sizes of11 kv single cable on existing / erected double pole including gi pipe 3 mtr long 6 dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 263 digging of trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 11 kv xlpe cables including cost of bricks, sand, clamps etc. 264 digging of trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying 33 kv xlpe cables including cost of bricks, sand, clamps etc. 265 testing & commissioning of 11 kv grade 3 core 185 sqmm xlpe power underground cable 266 testing & commissioning of 33 kv 3 core 300 sqmm xlpe power underground cable 267 earthing of pole by earthing coil ( with salt & charcoal ) 268 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 269 ms danger board with back calmps & nuts and boltsas per technical specification 270 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 271 numbering of pole of each support as per technical specification and scope of work 272 supply & installation of 11kv vcb switchgear panel outgoing for extra feeder under feeder segregation / bifurcartion works. 273 control room extension 274 excavation in foundation in ordinary soil ( loam day or sand ) including lift upto 1.5 mtr. and lead upto 30 m and including filling watering and ramming of excavated earth into the building and sides of the foundation trenches or in to the plinth and directed by the engineer in charge upto a distance of 30 m from the foundation 275 concrete with 4 cm.gauge 1st class brick ballast ( class 150 ) coarse sand ( f.m.1.8 to 2.5 ) and cement in proportion of 10:5:1 in foundation and under floors including supply of all materials labour and t&p etc. required for propoer complrtion of work. 276 1st class brick work in 1:6 cement & coarse sand ( f.m.1.8 to 2.5 ) morter in foundation & plinth including supply of all materials, labour and t&p etc. required for propoer complrtion of work. 277 1st class brick ( class 150 ) work in 1:6 cement & coarse sand ( fm 1.8 to 2.50 ) morter but in supper structure but for wall of one & half brick thick including supply of all materials , labour t&p etc required for propoer completion of work. 278 st class brick ( class 150 ) work in 1:6 cement & coarse sand ( fm1.8 to 2.50 ) morter but in supper structure but for wall of one brick thick including supply of all materials , labour t&p etc required for proper completion of work. 279 mild steel or iron in plain work such as reinforced concrete or reinforced brick work ( when not included in over all rate ) wrought to required shape as necessary i / c bending for proper completion of the work & i / c supply of steel its wastege shall be measured stee! shall not be supplied by the department. 280 mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks roof work gates etc. wrought to required form including holes riveting or welding where necessary and also including supply of steel bolts nuts wastage etc.and their fixing required for proper completion of the work ( steel is not supplies by the department ) 281 r.c.c. work with cement approved coarse sand ( p.m. 1.8 to 2.5 ) and 2 cm gauge graded approved hard stone ballast in proportion 1:2:4 in lintels of doors & windows excluding supply of reinforcement and its bending but including its fixing & binding the same with 24 bwg g.i. binding wire and including necessary centring & shuttering etc. and also including cost of all materials, labour and t&p etc. required for proper completion of the work. 282 r.c.c. work with cement approved coarse sand ( p.m. 1.8 to 2.5 ) and 2 cm gauge graded approved hard stone ballast in proportion 1:1:5:3 for slab excluding supply of reinforcement and its bending but including its fixing & binding the same with 24 bwg g.i binding wire and i / c necessary centering & shuttering etc. and also i / c cost of all materials, labour and t&p etc. required for proper completion of the work. 283 12 mm thick plaster with cement morter consisting of 1 aart: sparts of approved coarse sand on fare surface ncluding supply of all materials, labour t&p etc. required for proper completion of work. 284 supply & fixing fan hooks 16 mm dia 200 mm long complete. 285 p / f glass strip of 40 mm depth in joints of floor and skirting at the time of laying, floors flush with floor level ncluding labour. tools and plants etc. complete. 286 40 mm thick 1:2:4 floor without base concrete floor with cement, approved coarse sand &2 cm. graded approved stone ballast ( shingle for bareily ) laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and giving them a uniform finish including supply of all labour and t&p etc required for proper completion of work. 287 white washing three coats of new surface including cost of all materials, labour and t&p etc. required for proper completion of the work exept cost of angle iron and flat. 288 one priming coat and two coats of dry distemper castle or equivalent make on new surface including cost of all materials, labour and t&p etc. required for proper completion of the work. 289 finishing walls with water proof cement paint of approved make and quality over new work with three coats to give an even shade including supply of all materials, labour and t&p etc.required for proper completion of the work. 290 writing point for light with 1.5 sq.mm. frpvc insulated multistrand single core copper conductor cable in surface conduit pipe, complete with copper earth continuity wire, piano type switch & ceiling rose / angle / button holder on 3mm thick phenolic aminated backelite sheet etc. complete in all respects, as directed including matching colour wash. 291 wiring point for fan / fresh air fan ( light duty exhaust fan ) n pvc conduit with 1.5 sq.mm. fr pvc insulted multistrand copper condctor cable as earth wire drawn nside the conduit. 292 s / f batten / angle holder of approved quality complete n all respect. 293 painting or varnishing on new iron work in small areas or new wood work with one coat of ready mixed priming paint and two coats of approved superior quality ready mixed paint ( luxol ) or equivalent brand or varnish i / c supply of all materials, labour t&p etc. required for proper completion of work.paint to be used should conform i.s.103 1950 294 dismantling brick work or stone work in time or cement mortar and including stacking of materials as directed by e / l within distance of 60mtr. 295 dismantling existing plaster including disposal of refuse as directed by e / l within a distance of 60 mtr. 296 dismantling c.c brick or brick or granolithic floors including base concrete and including stacking of dismantled material as directed by e / l within a distance of 60 mtr. 297 road crossings on 9 meter and 11 meter poles 298 9 meter long / 400 kg pcc poles ( pcc pole as per state practice ) 299 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 300 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 301 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 302 stone pad for supports as per scope of works & drawing ( 450x450x75 mm ) 303 red oxide paint as per ts 304 aluminium paint as per ts 305 v cross arm supporting channel ( 100x50x6 mm ) , 3000mm long with holding clamps , bolts and nuts. 306 11kv v type cross arm ( m.s channel 75x40x6mm ) welded with ms angel ( 50x50x6 ) ( weight 10.37 kg ) with bolts and nuts 307 11kv bridling v type cross arm ( m.s channel 75x40x6mm ) welded with ms angel ( 50x50x6 ) ( weight 10.5 kg ) with bolts and nuts 308 guarding cross arm ( 75x40x6 mm ) 2210 mm long with eye bolts ( 16mm dia ) 309 back clamp for guarding cross arm ( 50x8 mm ) ( weight 1.15 kg ) with nut & bolts. 310 cross arm holding clamps ( ms flat 50x8 mm ) ( weight 1.33 kg ) with bolts and nuts 311 f bracket ms flat ( 50x8 mm ) ( weight 1.56 kg ) with nut and bolts 312 distribution tie for pin insulator 313 11 kv polymer pin insulators 5 kn with nuts 314 6 swg gi wire along the span 315 8 swg gi wire across the span 316 12 swg gi wire for binding 317 earthing of pole by earthing coil ( with salt & charcoal ) 318 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 319 ms danger board with back calmps & nuts and boltsas per technical specification 320 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 321 numbering of pole of each support as per technical specification and scope of work 322 relocation of 11 / .433 kv 3ph distribution transformer 323 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 324 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 325 stone pad for supports as per scope of works & drawing ( 300x300x75 mm ) 326 shifting of distribution transformer and all fabricated items and other allied materials 327 distribution transformer for segregated feeders 328 9 meter long / 400 kg pcc poles ( pcc pole as per state practice ) 329 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 330 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 331 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 332 stone pad for supports as per scope of works & drawing ( 450x450x75 mm ) 333 red oxide paint as per ts 334 aluminium paint as per ts 335 transformer top channel ( 100x50x6mm ) 2800 mm long with nuts & bolts 336 ab switch mounting channel ( 100x50x6mm ) 2800 mm long with nuts & bolts 337 back clamp for ab switch mounting channel ( 50x8mm ) ( weight 1.8 kg ) with nuts & bolts 338 do fuse mounting channel ( 75x40x6mm ) 2800 mm long with nuts & bolts 339 back clamp for do fuse mounting channel ( 50x8mm ) ( weight 1.9 kg ) with nuts & bolts 340 transformer mounting channel ( 100x50x6mm ) 2800 mm with nuts & bolts 341 transformer mounting channel support ( 50x50x6mm ) 500 mm long with nuts & bolts. 342 transformer belting angle ( 50x50x6mm ) 2800 mm longwith nuts & bolts 343 transformer belting angle support ( 35x35x6 mm ) 500 mm long with nuts & bolts 344 11 kv polymer disc insulator 45 kn ( b&s type ) along with suitable hardware fittings 345 11 kv polymer pin insulators 5 kn with nuts 346 11 / 0.230 kv distribution transformer 16 kva single phase aluminum wound dtr 347 11 / 0.4 kv distribution transformer 25 kva three phase aluminum wound dtr 348 11 / 0.4 kv distribution transformer 63 kva three phase aluminum wound dtr 349 11 / 0.4 kv distribution transformer 100 kva three phase aluminum wound dtr 350 11 / 0.4 kv distribution transformer 250 kva three phase copper wound dtr 351 acsr weasel counductor for jumpering 352 bimetallic connector for ht & lt side of the transformer 353 t clamp & pg clamp for jumpering 354 lt distribution box polyester sheet moulding compound ( smc ) for 16 kva distribution transformer with arrangement of suitable bus bars and mccbs as per scope of works of sbd 355 lt distribution box polyester sheet moulding compound ( smc ) for 25 kva distribution transformer with arrangement of suitable bus bars & mccbs as per scope of works of sbd 356 lt distribution box polyester sheet moulding compound ( smc ) for 63 kva distribution transformer with arrangement of suitable bus bars & mccbs as per scope of works of sbd 357 lt distribution box polyester sheet moulding compound ( smc ) for 100 kva distribution transformer with arrangement of suitable bus bars & mccbs as per scope of works of sbd 358 lt distribution box polyester sheet moulding compound ( smc ) for 250 kva distribution transformer with arrangement of suitable bus bars & mccbs as per scope of works of sbd 359 back clamp support for ltdb ( 65x8 mm ) 360 whole current a.c. single phase smart energy meter 361 whole current a.c. three phase smart energy meter 362 1cx16 sqmm 1.1kv xlpe cable with suitable lugs and glands and cable ties 363 1cx35 sqmm 1.1kv xlpe cable with suitable lugs and glands and cable ties 364 1cx70 sqmm 1.1kv xlpe cable with suitable lugs and glands and cable ties 365 1cx150 sqmm 1.1kv xlpe cable with suitable lugs and glands and cable ties 366 clamps for lt service cable support 367 9 kv, 5 ka distribution class la 368 11 kv, 3 ph, 200 a, 3 pin type vertical mounting typeab switch along with support insulators, base channel, down pipe, operating handle and support, etc. complete asper technical specifications, scope of works and approved drawings 369 11 kv, 3 ph, drop out fuse set ( set of 3 units ) along with support insulators, base channel, fuse barrel etc. complete asper technical specifications, scope of works and approved drawings 370 gi earthing pipe of 40 mm dia & 3000 mm long as per is 1161 371 gi flat ( 50x6 mm ) 372 gi wire 8swg 373 gi flat ( 25x3 mm ) 374 ms danger board with back calmps & nuts and boltsas per technical specification 375 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 376 numbering of pole of each support as per technical specification and scope of work 377 lt line for segregated feeders 378 route survey and pole spotting and mapping ( as per employer requirement of sbd ) 379 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 380 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 381 stone pad for supports as per scope of works & drawing ( 300x300x75 mm ) 382 single phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with calmps ( 40x3 mm ) and nut & bolts 383 three phase glass fiber reinforced polyester sheet moulding compound ( smc ) pole top distribution box with calmps ( 40x3 mm ) and nut & bolts 384 2cx25 sqmm xlpe aluminium conductor cable for single phase db incomer 385 4cx35 sqmm xlpe aluminium conductor cable for three phase db incomer 386 earthing of pole by earthing coil ( with salt & charcoal ) 387 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 388 aerial bunched xlpe cable 1x25 ( ph ) + 1x25 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 389 aerial bunched xlpe cable 3x50 ( ph ) + 1x35 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 390 aerial bunched xlpe cable 3x95 ( ph ) + 1x70 ( bare messenger cum neutral ) + 1x16 ( insulated street lighting ) sqmm 391 lt pole clamp ( 50x8mm ) ( 2.56 kg ) with nut and bolts 392 lt eye hook 393 suspension clamp 394 dead end clamp 395 insulation piercing connectors / connector type i ( ab cable to ab cable ) 396 insulation piercing connectors type ii ( ab cable to service cable ) 397 end cap for ab cable 25 sqmm 398 end cap for ab cable 50 sqmm 399 end cap for ab cable 95 sqmm 400 feeder bifurcation ( 33kv line ) 401 overhead 33 kv new feeder 402 route survey and pole spotting and mapping ( as per employer requirement of sbd ) 403 9 meter long / 400 kg pcc poles ( pcc pole as per state practice ) 404 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 405 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 406 13 m long steel tubular poles with welded steel base plate of designation 410 sp 72 407 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 408 stone pad for supports as per scope of works & drawing ( 450x450x75 mm ) 409 red oxide paint as per ts 410 aluminium paint as per ts 411 v type cross arm ( ms channel 100x50x6 mm 1980 mm long ) welded with ms angel ( 65x65x6 mm 935 mm long ) with bolts and nuts 412 cross arm holding clamps ( ms flat 65x8 mm ) with bolts and nuts 413 f bracket ( ms channel 100x50x6 mm ( 475 mm long ) welded with ms angle 75x75x6 mm ( 75 mm long ) with bolts and nuts 414 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 415 horizontal belting angle ( angle 65x65x6 mm ) 2240 mm long with bolts and nuts 416 cross bracing angle ( angle 65x65x6 mm ) 2500 mm long with bolts and nuts 417 bracing clamp top clamp ( flat 65x8 mm ) with bolts and nuts 418 bracing clamp bottom clamp ( flat 65x8 mm ) with bolts and nuts 419 fish plate for jumpering 420 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) acsr dog conductor 421 30 / 3.00 + 7 / 3.00 mm ( 200 sqmm al.area ) acsr panther conductor 422 pg clamp for dog conductor 423 pg clamp for panther conductor 424 armoured rod with ferrule 425 jointing sleeves aluminium 426 aluminium binding wire and tape 427 33 kv polymer disc insulator 70 kn ( b&s type ) along with suitable hardware fittings 428 33 kv polymer pin insulators 10 kn with nuts 429 earthing of pole by earthing coil ( with salt & charcoal ) 430 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 431 ms danger board with back calmps & nuts and boltsas per technical specification 432 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 433 numbering of pole of each support as per technical specification and scope of work 434 underground 33 kv new feeder 435 radar route survey for route profile of any utility cables, pipes etc. along the route as per ts and scope of work 436 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 437 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 438 red oxide paint as per ts 439 aluminium paint as per ts 440 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 441 horizontal belting angle ( angle 65x65x6 mm ) 2240 mm long with bolts and nuts 442 cross bracing angle ( angle 65x65x6 mm ) 2500 mm long with bolts and nuts 443 bracing clamp top clamp ( flat 65x8 mm ) with bolts and nuts 444 bracing clamp bottom clamp ( flat 65x8 mm ) with bolts and nuts 445 fish plate for jumpering 446 33 kv polymer pin insulators 10 kn with nuts 447 heat shrinkable jointing kit indoor for 33 kv 3×300 sq.mm. xlpe cable 448 heat shrinkable jointing kit outdoor for 33 kv 3×300 sq.mm. xlpe cable 449 heat shrinkable cable jointing kit straight through for 33 kv 3×300 sq.mm. xlpe cable 450 road restoration chages for pucca road crossing 451 road restoration chages for kucchha road crossing 452 supply and placing of pre cast concrete manhole chambers of size 900mm x 900mm internal dimension x 800mm height & 100mm wall thickness ( heavy duty ) with concrete cover of 100mm thickness in the specified locations in the trench. 453 supply & erection of 33 kv single core 120 sqmm xlpe aluminium cable for jumpering 454 supply & erection of aluminum lugs 300 sq.mm. 455 supply & erection of cable warning tape 456 fixing of cable marker on cable route and inscription of feeder name and voltage on cable marker 457 supply of 33 kv 3×300 sqmm xlpe cable 458 earth digging, laying, termination / jointing, erection, testing & commissioning of 33 kv grade 3 core 300 sqmm xlpe power cable underground and backfilling with bricks, sands, excavated soil as per standard practise, levelling etc complete in all respect along with all accessories, earthing etc. and as per ts / approved drawing. 459 laying of 3x300 sq mm xlpe singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick, sand, stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. the ferruling of cable also include in this work ( all the material 460 laying of 3x300 sq mm xlpe twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick, sand, stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. the ferruling of cable also include in this work ( all the material 461 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 33 kv grade 3 core 300 sqmm xlpe power cable undergroundusing hdpe pipecomplete in all respect along with all accessories, earthing etc. and as per ts / approved drawing . 462 cable laying charges 463 pipe ( hdpe 160 mm dia ) for cable laying 464 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 33 kv grade 3 core 300 sqmm xlpe power cable undergroundwithout hdpe pipes in all respect along with all accessories, earthing etc. and as per ts / approved drawing . 465 cable laying charges 466 hoisting of following sizes of33 kv single cable on existing / erected double pole including gi pipe 3 mtr long 6 dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 467 testing & commissioning of 33 kv 3 core 300 sqmm xlpe power underground cable 468 earthing of pole by earthing coil ( with salt & charcoal ) 469 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 470 ms danger board with back calmps & nuts and boltsas per technical specification 471 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 472 numbering of pole of each support as per technical specification and scope of work 473 feeder bifurcation ( 11kv line ) 474 overhead 11 kv new feeder 475 route survey and pole spotting and mapping ( as per employer requirement of sbd ) 476 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 477 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 478 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 479 13 m long steel tubular poles with welded steel base plate of designation 410 sp 72 480 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 481 stone pad for supports as per scope of works & drawing ( 300x300x75 mm ) 482 red oxide paint as per ts 483 aluminium paint as per ts 484 11kv v type cross arm ( m.s channel 75x40x6mm ) welded with ms angel ( 50x50x6 ) ( weight 10.37 kg ) with bolts and nuts 485 cross arm holding clamps ( ms flat 50x8 mm ) ( weight 1.33 kg ) with bolts and nuts 486 f bracket ms flat ( 50x8 mm ) ( weight 1.56 kg ) with nut and bolts 487 cut point top channel ( 100x50x6 mm ) of length 230 mm along with nut & bolts 488 cut point bottom channel ( 100x50x6 mm ) of length 1150 mm along with nut & bolts 489 tapping horizontal cross arm ( 100x50x6 mm ) of length 1020 mm along with calmps ( 50x8 ) and nut and bolts 490 tapping top channel ( 100x50x6 mm ) of length 256 mm along with calmps ( 50x8 ) and nut and bolts 491 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 492 horizontal belting angle ( angle 50x50x6 mm ) 2240 mm long with bolts and nuts 493 cross bracing angle ( angle 50x50x6 mm ) 2500 mm long with bolts and nuts 494 belting clamp top clamp ( flat 50x8 mm ) ( weight 1.4 kg ) with bolts and nuts 495 belting clamp bottom clamp ( flat 50x8 mm ) ( weight 1.5 kg ) with bolts and nuts 496 fish plate for jumpering 497 6 / 2.59 + 1 / 2.59 mm ( 30 sqmm al. area ) acsr weasel conductors 498 6 / 3.35 + 1 / 3.35 mm ( 50 sqmm al. area ) acsr rabbit conductors 499 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) acsr dog conductor 500 pg clamp for weasel conductor 501 pg clamp for rabbit conductor 502 pg clamp for dog conductor 503 distribution tie for pin insulator 504 armoured rod with ferrule 505 jointing sleeves aluminium 506 aluminium binding wire and tape 507 11 kv polymer disc insulator 45 kn ( b&s type ) along with suitable hardware fittings 508 11 kv polymer pin insulators 5 kn with nuts 509 11 kv 3c×185 sqmm xlpe cable 510 heat shrinkable jointing kit outdoor for 11 kv 3c×185 sq.mm. xlpe cable 511 heat shrinkable cable jointing kit straight through for 11 kv 3c×185 sq.mm. xlpe cable 512 hoisting of following sizes of11 kv single cable on existing / erected double pole including gi pipe 3 mtr long 6 dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 513 earthing of pole by earthing coil ( with salt & charcoal ) 514 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 515 ms danger board with back calmps & nuts and boltsas per technical specification 516 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 517 numbering of pole of each support as per technical specification and scope of work 518 underground 11 kv new feeder 519 radar route survey for route profile of any utility cables, pipes etc. along the route as per ts and scope of work 520 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 521 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 522 red oxide paint as per ts 523 aluminium paint as per ts 524 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 525 horizontal belting angle ( angle 50x50x6 mm ) 2240 mm long with bolts and nuts 526 cross bracing angle ( angle 50x50x6 mm ) 2500 mm long with bolts and nuts 527 belting clamp top clamp ( flat 50x8 mm ) ( weight 1.4 kg ) with bolts and nuts 528 belting clamp bottom clamp ( flat 50x8 mm ) ( weight 1.5 kg ) with bolts and nuts 529 fish plate for jumpering 530 11 kv polymer pin insulators 5 kn with nuts 531 heat shrinkable jointing kit indoor for 11 kv 3c×185 sq.mm. xlpe cable 532 heat shrinkable jointing kit indoor for 11 kv 3×300 sq.mm. xlpe cable 533 heat shrinkable jointing kit outdoor for 11 kv 3c×185 sq.mm. xlpe cable 534 heat shrinkable jointing kit outdoor for 11 kv 3×300 sq.mm. xlpe cable 535 heat shrinkable cable jointing kit straight through for 11 kv 3c×185 sq.mm. xlpe cable 536 heat shrinkable cable jointing kit straight through for 11 kv 3×300 sq.mm. xlpe cable 537 road restoration chages for pucca road crossing 538 road restoration chages for kucchha road crossing 539 supply and placing of pre cast concrete manhole chambers of size 900mm x 900mm internal dimension x 800mm height & 100mm wall thickness ( heavy duty ) with concrete cover of 100mm thickness in the specified locations in the trench. 540 supply & erection of 11 kv single core 95 sqmm xlpe aluminium cable for jumpering 541 supply & erection of aluminum lugs 185 sq.mm. 542 supply & erection of aluminum lugs 300 sq.mm. 543 supply & erection of cable warning tape 544 fixing of cable marker on cable route and inscription of feeder name and voltage on cable marker 545 supply of 11 kv 3c×185 sqmm xlpe cable 546 supply of 11 kv 3×300 sqmm xlpe cable 547 earth digging, laying, termination / jointing, erection, testing & commissioning of 11 kv grade 3 core 185 / 300 sqmm xlpe power cable underground and backfilling with bricks, sands, excavated soil as per standard practise, levelling etc complete in all respect along with all accessories, earthing etc. and as per ts / approved drawing. 548 laying of 11 kv 3cx185 sq mm xlpe singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick, sand, stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. the ferruling of cable also include in this work ( all the material 549 laying of 11 kv 3x185 sq mm xlpe twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick, sand, stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. the ferruling of cable also include in this work ( all the material ) 550 laying of 3x300 sq mm xlpe singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick, sand, stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. the ferruling of cable also include in this work ( all the material 551 laying of 3x300 sq mm xlpe twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick, sand, stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. the ferruling of cable also include in this work ( all the material 552 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 11 kv grade 3 core 185 / 300 sqmm xlpe power cable undergroundusing hdpe pipecomplete in all respect along with all accessories, earthing etc. and as per ts / approved drawing . 553 laying of 11 kv 3c×185 sqmm xlpe cable 554 laying of 11 kv 3×300 sqmm xlpe cable 555 pipe ( hdpe 160 mm dia ) for cable laying 556 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 11 kv grade 3 core 185 / 300 sqmm xlpe power cable undergroundwithout hdpe pipes in all respect along with all accessories, earthing etc. and as per ts / approved drawing. 557 laying of 11 kv 3c×185 sqmm xlpe cable 558 laying of 11 kv 3×300 sqmm xlpe cable 559 hoisting of following sizes of11 kv single cable on existing / erected double pole including gi pipe 3 mtr long 6 dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 560 testing & commissioning of 11 kv grade 3 core 185 sqmm xlpe power underground cable 561 testing & commissioning of 11 kv 3 core 300 sqmm xlpe power underground cable 562 earthing of pole by earthing coil ( with salt & charcoal ) 563 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 564 ms danger board with back calmps & nuts and boltsas per technical specification 565 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 566 numbering of pole of each support as per technical specification and scope of work 567 augumentation / reconductoring of 33kv line 568 overhead 33 kv augumentation / reconductoring 569 route survey and pole spotting and mapping ( as per employer requirement of sbd ) 570 9 meter long / 400 kg pcc poles ( pcc pole as per state practice ) 571 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 572 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 573 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 574 stone pad for supports as per scope of works & drawing ( 450x450x75 mm ) 575 red oxide paint as per ts 576 aluminium paint as per ts 577 v type cross arm ( ms channel 100x50x6 mm 1980 mm long ) welded with ms angel ( 65x65x6 mm 935 mm long ) with bolts and nuts 578 cross arm holding clamps ( ms flat 65x8 mm ) with bolts and nuts 579 f bracket ( ms channel 100x50x6 mm ( 475 mm long ) welded with ms angle 75x75x6 mm ( 75 mm long ) with bolts and nuts 580 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 581 horizontal belting angle ( angle 65x65x6 mm ) 2240 mm long with bolts and nuts 582 cross bracing angle ( angle 65x65x6 mm ) 2500 mm long with bolts and nuts 583 bracing clamp top clamp ( flat 65x8 mm ) with bolts and nuts 584 bracing clamp bottom clamp ( flat 65x8 mm ) with bolts and nuts 585 fish plate for jumpering 586 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) acsr dog conductor 587 30 / 3.00 + 7 / 3.00 mm ( 200 sqmm al.area ) acsr panther conductor 588 pg clamp for dog conductor 589 pg clamp for panther conductor 590 armoured rod with ferrule 591 jointing sleeves aluminium 592 aluminium binding wire and tape 593 33 kv polymer disc insulator 70 kn ( b&s type ) along with suitable hardware fittings 594 33 kv polymer pin insulators 10 kn with nuts 595 earthing of pole by earthing coil ( with salt & charcoal ) 596 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 597 ms danger board with back calmps & nuts and boltsas per technical specification 598 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 599 numbering of pole of each support as per technical specification and scope of work 600 removal of existing material and shifting to mvvnl store 601 underground 33 kv augumentation / reconductoring 602 radar route survey for route profile of any utility cables, pipes etc. along the route as per ts and scope of work 603 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 604 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 605 red oxide paint as per ts 606 aluminium paint as per ts 607 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 608 horizontal belting angle ( angle 65x65x6 mm ) 2240 mm long with bolts and nuts 609 cross bracing angle ( angle 65x65x6 mm ) 2500 mm long with bolts and nuts 610 bracing clamp top clamp ( flat 65x8 mm ) with bolts and nuts 611 bracing clamp bottom clamp ( flat 65x8 mm ) with bolts and nuts 612 fish plate for jumpering 613 33 kv polymer pin insulators 10 kn with nuts 614 heat shrinkable jointing kit indoor for 33 kv 3×300 sq.mm. xlpe cable 615 heat shrinkable jointing kit outdoor for 33 kv 3×300 sq.mm. xlpe cable 616 heat shrinkable cable jointing kit straight through for 33 kv 3×300 sq.mm. xlpe cable 617 road restoration chages for pucca road crossing 618 road restoration chages for kucchha road crossing 619 supply and placing of pre cast concrete manhole chambers of size 900mm x 900mm internal dimension x 800mm height & 100mm wall thickness ( heavy duty ) with concrete cover of 100mm thickness in the specified locations in the trench. 620 supply & erection of 33 kv single core 120 sqmm xlpe aluminium cable for jumpering 621 supply & erection of aluminum lugs 300 sq.mm. 622 supply & erection of cable warning tape 623 fixing of cable marker on cable route and inscription of feeder name and voltage on cable marker 624 supply 33 kv 3×300 sqmm xlpe cable 625 earth digging, laying, termination / jointing, erection, testing & commissioning of 33 kv grade 3 core 300 sqmm xlpe power cable underground and backfilling with bricks, sands, excavated soil as per standard practise, levelling etc complete in all respect along with all accessories, earthing etc. and as per ts / approved drawing. 626 laying of 3x300 sq mm xlpe singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick, sand, stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. the ferruling of cable also include in this work ( all the material 627 laying of 3x300 sq mm xlpe twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick, sand, stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. the ferruling of cable also include in this work ( all the material 628 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 33 kv grade 3 core 300 sqmm xlpe power cable undergroundusing hdpe pipecomplete in all respect along with all accessories, earthing etc. and as per ts / approved drawing . 629 laying of 33 kv 3×300 sqmm xlpe cable 630 pipe ( hdpe 160 mm dia ) for cable laying 631 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 33 kv grade 3 core 300 sqmm xlpe power cable undergroundwithout hdpe pipes in all respect along with all accessories, earthing etc. and as per ts / approved drawing. 632 laying of 33 kv 3×300 sqmm xlpe cable 633 hoisting of following sizes of33 kv single cable on existing / erected double pole including gi pipe 3 mtr long 6 dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 634 testing & commissioning of 33 kv 3 core 300 sqmm xlpe power underground cable 635 earthing of pole by earthing coil ( with salt & charcoal ) 636 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 637 ms danger board with back calmps & nuts and boltsas per technical specification 638 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 639 numbering of pole of each support as per technical specification and scope of work 640 removal of existing material and shifting to mvvnl store 641 augumentation / reconductoring of 11kv line 642 overhead 11 kv augumentation / reconductoring 643 route survey and pole spotting and mapping ( as per employer requirement of sbd ) 644 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 645 foundation of pcc supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.268 cmt for each support ) 646 stone pad for supports as per scope of works & drawing ( 300x300x75 mm ) 647 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 648 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 649 red oxide paint as per ts 650 aluminium paint as per ts 651 11kv v type cross arm ( m.s channel 75x40x6mm ) welded with ms angel ( 50x50x6 ) ( weight 10.37 kg ) with bolts and nuts 652 cross arm holding clamps ( ms flat 50x8 mm ) ( weight 1.33 kg ) with bolts and nuts 653 f bracket ms flat ( 50x8 mm ) ( weight 1.56 kg ) with nut and bolts 654 cut point top channel ( 100x50x6 mm ) of length 230 mm along with nut & bolts 655 cut point bottom channel ( 100x50x6 mm ) of length 1150 mm along with nut & bolts 656 tapping horizontal cross arm ( 100x50x6 mm ) of length 1020 mm along with calmps ( 50x8 ) and nut and bolts 657 tapping top channel ( 100x50x6 mm ) of length 256 mm along with calmps ( 50x8 ) and nut and bolts 658 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 659 horizontal belting angle ( angle 50x50x6 mm ) 2240 mm long with bolts and nuts 660 cross bracing angle ( angle 50x50x6 mm ) 2500 mm long with bolts and nuts 661 belting clamp top clamp ( flat 50x8 mm ) ( weight 1.4 kg ) with bolts and nuts 662 belting clamp bottom clamp ( flat 50x8 mm ) ( weight 1.5 kg ) with bolts and nuts 663 fish plate for jumpering 664 6 / 2.59 + 1 / 2.59 mm ( 30 sqmm al. area ) acsr weasel conductors 665 6 / 3.35 + 1 / 3.35 mm ( 50 sqmm al. area ) acsr rabbit conductors 666 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) acsr dog conductor 667 pg clamp for weasel conductor 668 pg clamp for rabbit conductor 669 pg clamp for dog conductor 670 distribution tie for pin insulator 671 armoured rod with ferrule 672 jointing sleeves aluminium 673 aluminium binding wire and tape 674 11 kv polymer disc insulator 45 kn ( b&s type ) along with suitable hardware fittings 675 11 kv polymer pin insulators 5 kn with nuts 676 earthing of pole by earthing coil ( with salt & charcoal ) 677 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 678 ms danger board with back calmps & nuts and boltsas per technical specification 679 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 680 numbering of pole of each support as per technical specification and scope of work 681 removal of existing material and shifting to mvvnl store 682 underground 11 kv augumentation / reconductoring 683 radar route survey for route profile of any utility cables, pipes etc. along the route as per ts and scope of work 684 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 685 foundation of stp supports as per scope of works, cement concreting ( 1:2:4 ) ( 0.5 cmt for each support & .014 cmt. for muffing ) 686 red oxide paint as per ts 687 aluminium paint as per ts 688 dp top channel ( channel 100x50x6mm ) 2240 mm longwith bolts and nuts 689 horizontal belting angle ( angle 50x50x6 mm ) 2240 mm long with bolts and nuts 690 cross bracing angle ( angle 50x50x6 mm ) 2500 mm long with bolts and nuts 691 belting clamp top clamp ( flat 50x8 mm ) ( weight 1.4 kg ) with bolts and nuts 692 belting clamp bottom clamp ( flat 50x8 mm ) ( weight 1.5 kg ) with bolts and nuts 693 fish plate for jumpering 694 11 kv polymer pin insulators 5 kn with nuts 695 heat shrinkable jointing kit indoor for 11 kv 3c×185 sq.mm. xlpe cable 696 heat shrinkable jointing kit indoor for 11 kv 3×300 sq.mm. xlpe cable 697 heat shrinkable jointing kit outdoor for 11 kv 3c×185 sq.mm. xlpe cable 698 heat shrinkable jointing kit outdoor for 11 kv 3×300 sq.mm. xlpe cable 699 heat shrinkable cable jointing kit straight through for 11 kv 3c×185 sq.mm. xlpe cable 700 heat shrinkable cable jointing kit straight through for 11 kv 3×300 sq.mm. xlpe cable 701 road restoration chages for pucca road crossing 702 road restoration chages for kucchha road crossing 703 supply and placing of pre cast concrete manhole chambers of size 900mm x 900mm internal dimension x 800mm height & 100mm wall thickness ( heavy duty ) with concrete cover of 100mm thickness in the specified locations in the trench. 704 supply & erection of 11 kv single core 95 sqmm xlpe aluminium cable for jumpering 705 supply & erection of aluminum lugs 185 sq.mm. 706 supply & erection of aluminum lugs 300 sq.mm. 707 supply & erection of cable warning tape 708 fixing of cable marker on cable route and inscription of feeder name and voltage on cable marker 709 supply of 11 kv 3c×185 sqmm xlpe cable 710 supply of 11 kv 3×300 sqmm xlpe cable 711 earth digging, laying, termination / jointing, erection, testing & commissioning of 11 kv grade 3 core 185 / 300 sqmm xlpe power cable underground and backfilling with bricks, sands, excavated soil as per standard practise, levelling etc complete in all respect along with all accessories, earthing etc. and as per ts / approved drawing. 712 laying of 11 kv 3cx185 sq mm xlpe singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick, sand, stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. the ferruling of cable also include in this work ( all the material 713 laying of 11 kv 3x185 sq mm xlpe twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick, sand, stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. the ferruling of cable also include in this work ( all the material ) 714 laying of 3x300 sq mm xlpe singlecableby digging of trench 1100 mm, deep, 750 mm wide its boxing with brick, sand, stone slabafter laying of cable separation of cable by brick wall up to stone slab filling and proper levelling& ramming. the ferruling of cable also include in this work ( all the material 715 laying of 3x300 sq mm xlpe twin cableby digging of trench 1100 mm deep, 750 mm wide its boxing with brick, sand, stone slab after laying of cable separation of cable by brick wall up to stone slab filling and proper levelling & ramming. the ferruling of cable also include in this work ( all the material 716 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 11 kv grade 3 core 185 / 300 sqmm xlpe power cable undergroundusing hdpe pipecomplete in all respect along with all accessories, earthing etc. and as per ts / approved drawing . 717 laying of 11 kv 3c×185 sqmm xlpe cable 718 laying of 11 kv 3×300 sqmm xlpe cable 719 pipe ( hdpe 160 mm dia ) for cable laying 720 earth digging by horizontal directional drilling ( hdd ) method, laying, termination / jointing, erection, testing & commissioning of 11 kv grade 3 core 185 / 300 sqmm xlpe power cable undergroundwithout hdpe pipes in all respect along with all accessories, earthing etc. and as per ts / approved drawing . 721 laying of 11 kv 3c×185 sqmm xlpe cable 722 laying of 11 kv 3×300 sqmm xlpe cable 723 hoisting of following sizes of11 kv single cable on existing / erected double pole including gi pipe 3 mtr long 6 dia including jumpering, dressing of cable with required all necessary clamps and nut, bolts. ( all the material shall be arranged by contractor ) 724 testing & commissioning of 11 kv grade 3 core 185 sqmm xlpe power underground cable 725 testing & commissioning of 11 kv 3 core 300 sqmm xlpe power underground cable 726 earthing of pole by earthing coil ( with salt & charcoal ) 727 8 swg gi wire for pole, db earthingwith gi nuts, bolts & washers 728 ms danger board with back calmps & nuts and boltsas per technical specification 729 anti climbing device 3.5 kgs, 2.5mm dia ( 12 swg ) galvanized barbed wire on each 11 kv support as per scope of works &ts 730 numbering of pole of each support as per technical specification and scope of work 731 removal of existing material and shifting to mvvnl store 732 lt line with underground cabling 733 radar route survey for route profile of any utility cables, pipes etc. along the route as per ts and scope of work 734 supply & laying of lt aluminium xlpe cable 1cx630 sq.mm. 735 supply & laying of lt aluminium xlpe cable 1cx400 sq.mm. 736 supply of 1100 v grade, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cable of 3.5cx70 sqmm 737 supply of 1100 v grade, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cable of 3.5cx150 sqmm 738 supply of 1100 v grade, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cable of 3.5cx240 sqmm 739 laying of 1100 v grade 3.5cx70 sqmm, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cable to be laid underground in trenches. 740 laying of 1100 v grade 3.5cx150 sqmm, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cable to be laid underground in trenches. 741 laying of 1100 v grade 3.5cx240 sqmm, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cable to be laid underground in trenches. 742 laying of 1100 v grade 3.5cx70 sqmm by horizontal directional drilling ( hdd ) method, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cable to be laid underground in hdpe pipe. 743 laying of 1100 v grade 3.5cx150 sqmm by horizontal directional drilling ( hdd ) method, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cable to be laid underground in hdpe pipe. 744 laying of 1100 v grade 3.5cx240 sqmm by horizontal directional drilling ( hdd ) method, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cable to be laid underground in hdpe pipe. 745 cable end termination using total double compression brass glands and crimping type aluminium thimbles for 3.5cx70 sqmm 746 cable end termination using total double compression brass glands and crimping type aluminium thimbles for 3.5cx150 sqmm 747 cable end termination using total double compression brass glands and crimping type aluminium thimbles for 3.5cx240 sqmm 748 digging of trench by excavation of earth, laying of bricks to cover the cable and filling of sand & earth ramming and dressing properly with complete job for laying of 1100 v grade, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cables. 749 back fillng & restoring the road to make it as original including supply of all material. 750 supply & laying of hdpe pipe of following size by horizontal drilling for underground piping ( trenchless ) for above cable at road crossings. min depth of pipe shall be 1.2 m below surface. 751 160 mm dia 752 110 mm dia 753 50 mm dia 754 supply and marking of manhole 750x600 mm with manhole cover for pullinglt cable in lanes by lanes 755 supply , installation and testing of 7x20 swg gi wire for earthing along cables. 756 supply and laying of pipe for service cable to houses. 757 gl pipe of 50 mm dia ( external area ) 758 gl pipe of 40 mm dia ( external area ) 759 pvc pipe heavy gauge 50 mm dia ( underground area ) 760 pvc pipe heavy gauge 40 mm dia ( underground area ) 761 supply and installation of rcc pipe of folloing size: 762 150 mm 763 200 mm 764 300 mm 765 supply and installation of 8 swg earthing gi wire 766 supply and making steel structure work and painting the same with two coats of primer and two coats of enamel paint. 767 supply and laying ( in gi pipe ) of 1100 v grade, pvc sheathed steel strip armoured, aluminum conductor lt xlpe insulated cable of size 2x10 sq.mm. xlpe ( for street light ) 768 supply & laying of gl pipe of 40 mm dia. underground 769 supply & installation of junction box on stp with 900 mm long gi pipe 25 mm dia. with clamps for street light connection. 770 supply and erection of earthing 40 mm dia 15 m. long g.i.pipe vertically for earthing having 12mm dia holes spaced 75 mm apart drilled up to 2m from the bottom all complete as per specification 771 fixing of gi strip of following sizes with hardware, mounting clamps etc.: 772 25 x 3 mm. gi strip 773 32 x 6 mm. gi strip 774 50 x 6 mm. gi strip 775 dismantling of lt overhead line and transportation of dismantled material to mvvnl stores. 776 supply of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubical should be weather proof, dust proof, vermin proof and in closer protection shall be ip 54 ( suitable for outdoor applications ) as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 14 swg crca sheet steel & provided with 16swg hinged door including suitable foundation, main lt panel at substation 1000 & 630 kva ( type a 1 ) incomer 1 no. 1250 amp. tp mdo acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ( outgoing 4 sets of 400 amp. tp mccb with spreader & extended handle ) ( 2 sets of 250amp. tp mccb with spreader & extended handle ) ( 2 sets of 100 0amp. tp mccb with spreader & extended handle ) 777 supply of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubicle should be weather proof, dust proof, vermin proof and in closer protection shall be ip 54 ( suitable for outdoor applications ) as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 14 swg crca sheet steel & provided with 16swg hinged door including suitable foundation, main lt panel at substation 400 kva ( type a 2 ) ( incomer 1 set of 800 amp.tp mdo acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ( outgoing 6 sets of 250 amp. tp mccb with spreader & extended handle ( 5no.+1no. capacitor panel ) ) ( 2 sets of 100 amp. tp mccb with spreader & extended handle ) 778 supply of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubical should be weather proof, dust proof, vermin proof and in closer protection shall be ip 54 ( suitable for outdoor applications ) as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 14 swg crca sheet steel & provided with 16swg hinged door including suitable foundation, main lt panel at substation 250 kva ( type a 3 ) ( incomer 1 set of 630 amp. tp mdo acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ) ( outgoing 5 sets of 250 amp. tp mccb with spreader & extended handle ( 4no.+1no. capacitor panel ) ) ( 2 sets of 100 amp. tp mccb with spreader & extended handle ) 779 supply of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubical should be weather proof, dust proof, vermin proof and in closer protection shall be ip 54 ( suitable for outdoor applications ) as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 14 swg crca sheet steel & provided with 16swg hinged door including suitable foundation, main lt panel at substation 160 kva ( type a 4 ) ( incomer 1 set of 400 amp. tp mdo acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ( outgoing 4 sets of 250 amp. tp mccb with spreader & extended handle ( 3no.+1no. capacitor panel ) ) ( 2 sets of 100 amp. tp mccb with spreader & extended handle ) 780 supply of outdoor type lt disribution boards with a rupturing capacity of 50ka at 415v or as called for individual items ( cpri approved manufacturer ) , openable in front and back suitable for 3 plase, 4 wire, 50hz ac supply and an ambient temperature of 45 deg. c. the cubicle should be weather proof, dust proof, vermin proof and enclosure protection shall be ip 54 ( suitable for outdoor applications ) as per is 2147 1962 and is: 8623. the panels / switches boards shall be fabricated out of 14 swg crca sheet steel and provided with 16 swg hinged doors including suitable foundation. main lt panel at sub station 100kva ( type a 5 ) incomer 1 set of 250 amp. tp mccb with spreader & extended handlemetering on incomer 1 set of digital ammeter with ass 1 set of digital voltmeter with vss 1 set of led type phase indicating light ( 22.5 mm. ) with control mcbsoutgoing 3 set of 63 amp. tp mccb with spreader & extended handle ( 2 nos. + 1 no. for capacitor panel ) 3 set of100 amp. tp mccb with spreader & extended handle 781 supply of outdoor type lt disribution boards with a rupturing capacity of 50ka at 415v or as called for individual items ( cpri approved manufacturer ) , openable in front and back suitable for 3 plase, 4 wire, 50hz ac supply and an ambient temperature of 45 deg. c. the cubicle should be weather proof, dust proof, vermin proof and enclosure protection shall be ip 54 ( suitable for outdoor applications ) as per is 2147 1962 and is: 8623. the panels / switches boards shall be fabricated out of 14 swg crca sheet steel and provided with 16 swg hinged doors including suitable foundation. main lt panel at sub station 63 & 25kva ( type a 6 ) incomer 1 set of 160 amp. tp mccb with spreader & extended handlemetering on incomer 1 set of digital ammeter with ass 1 set of digital voltmeter with vss 1 set of led type phase indicating light ( 22.5 mm. ) with control mcbsoutgoing 4 set of 63 amp. tp mccb with spreader & extended handle 1 set of32 amp. tp mccb with spreader & extended handle ( for capacitor panel ) 782 supply , installation, testing & commissioning of outdoor type feeder pillar panel to be made of 2 mm crca sheet and covers will be 1.6mm crca sheet duly powder coated paint with 400 amps al. busbar. ( type b1 ) incomer 250 amp. tp mccb 1 no.outgoing 63 amp. tp mccb 6 nos. the cubicle should be weather proof, dust proof, vermin proof and enclosure protection shall be ip 54 ( suitable for outdoor applications ) as per is 2147 1962 and is: 8623. 783 supply , installation, testing & commissioning of outdoor type feeder pillar panel to be made of 2 mm crca sheet and covers will be 1.6mm crca sheet duly powder coated paint with 300 amps al. busbar. ( type b2 ) incomer 250 amp. tp mccb 1 no.outgoing 63 amp. tp mccb 5 nos. the cubicle should be weather proof, dust proof, vermin proof and enclosure protection shall be ip 54 ( suitable for outdoor applications ) as per is 2147 1962 and is: 8623. 784 supply , installation, testing & commissioning of outdoor type feeder pillar panel to be made of 2 mm crca sheet and covers will be 1.6mm crca sheet duly powder coated paint with 300 amps al. busbar. ( type b3 ) incomer 100 amp. tp mccb 1 no.outgoing 63 amp. tp mccb 4 nos. the cubicle should be weather proof, dust proof, vermin proof and enclosure protection shall be ip 54 ( suitable for outdoor applications ) as per is 2147 1962 and is: 8623. 785 supply , installation, testing & commissioning of lockable distribution boxes of size 450x400mm with bus bar 100 amp. tpn to feed upto 10 houses ( type c ) . the cubicle should be weather proof, dust proof, vermin proof and enclosure protection shall be ip 54 ( suitable for outdoor applications ) as per is 2147 1962 and is: 8623.the panels / switches boards shall be fabricated out of 14 swg crca sheet steel and provided with 16 swg hinged doors including suitable foundation 786 supply of steel structure of size 65x65x6 mm ( m.s. angle ) including supply of nut bolt and washres. 787 supply and laying of single phase ( 2cx4 sqmm ) xlpe armoured service cable 788 supply and laying of single phase ( 2cx6 sqmm ) xlpe armoured service cable 789 supply and laying of three phase ( 4cx16 sqmm ) xlpe armoured service cable 790 supply & installation of single coil earthing at type a, b and double coil earthing at type c panels 791 supply & erection of plinth for outdoor type lt disribution boards ( a type ) and distribution feeder pillar box ( b type ) 792 supply & erection of plinth for outdoor type lt disribution sevice pillar ( c type ) 793 supply & erection of single phase poly carbonate meter box after removal of existing meter box and connections of meters with armoured cable laid along with resealing of meter with seals provided by mvvnl 794 supply & erection of three phase poly carbonate meter box after removal of existing meter box and connections of meters with armoured cable laid along with resealing of meter with seals provided by mvvnl 795 testing & commissioning of 3.5 core 240 sqmm xlpe power underground cable 796 testing & commissioning of 3.5 core 150 sqmm xlpe power underground cable 797 testing & commissioning of 3.5 core 70 sqmm xlpe power underground cable 798 installation of capacitor bank 799 installation of capacitor bank at 33 / 11 kv power transformer 800 12.65 kv, 1980 kvar, 3 phase, 50 c / s, outdoor type , capacitor bank having two variable step of 792 kvar & one variable steps of 396 kvar. bank shall be complete with capacitor units of 264 / 132 kvar, aluminium busbars, pin & post insulators, expulsion fuses etc. 801 12.65 kv, 3960 kvar, 3 phase, 50 c / s, outdoor type, capacitor bank having two variable step of 792 kvar & two variable steps of 1188 kvar. bank shall be complete with capacitor units of264 / 396 kvar, aluminimum busbars, pin & post insulators, expulsion fuses etc. 802 0.79 kvar for 1188 kvar step 803 0.52 kvar for 792 kvar step 804 0.25 kvar for 396 kvar step 805 11 kv, 3 phase oil cooled rvt 806 12 kv 3 phase outdoor type metal enclosed vacuum capacitor switches. 807 11 kv, 400 amp, off load isolator with earth switch and mounting structure. 808 9 kv, 10 ka, station class, lightning arrestors 809 indoor type automatic control unit 810 hot dip galvanised structures for complete system 811 control cables, lugs / thimble, junction box etc. 812 11 kv xlpe insulated 3x120 mm2armoured 813 indoor temination kit 814 outdoor temination kit 815 11 kv vcb switchgear with complete arangement for connection with existing 11 kv bus bar. 816 casting of civil foundation 817 cable trench for laying of power / control cables. 818 earthing for structure and las by pipe in pipe earthing ( gi earthing pipe of 40 mm dia & 3000 mm long as per is 1161 ) 819 gi strip of size 50x6 mm for connection of earthing with equipment 820 installation of capacitor bank at 11 / 0.415 kv distribution transformer 821 lt pole cap gas / resin filled mpp ( metalized polypropylene ) shunt capacitors 440v, 10 kvar, 3 phase 50 hz, ip65 with fault indication. 822 lt pole cap gas / resin filled mpp ( metalized polypropylene ) shunt capacitors 440v, 25 kvar, 3 phase 50 hz, ip65 with fault indication. 823 lt pole cap gas / resin filled mpp ( metalized polypropylene ) shunt capacitors 440v, 40 kvar, 3 phase 50 hz, ip65 with fault indication. 824 suitable pole clamps with nuts and bolts 825 1cx25 sqmm xlpe cable along with connecting clamps for connection of dtr with capacitor bank 826 earthing of existing substation and distribution transformer 827 pipe earthing for substation ( 3000 mm long ) 828 spike earthing for existing dtr ( 2500mm long ) 829 installation of 11 kv horizontal isolator, ab switch and lt distribution boxfor distribution transformer 830 supply and erection of 11 kv horizontal isolator with complete allied materials 831 supply and erection of 11kv ab switch with complete allied materials 832 supply and erection of ltdb made out of crca ms for 63 kva dtr with all allied materials 833 supply and erection of ltdb made out of crca ms for 100 kva dtr with all allied materials 834 supply and erection of ltdb made out of crca ms for 250 kva dtr with all allied materials 835 supply and erection of ltdb made out of crca ms for 400 kva dtr with all allied materials 836 supply and erection of ltdb made out of crca ms for 630 kva dtr with all allied materials 837 supply and erection of ltdb made out of crca ms for 1000 kva dtr with all allied materials 838 miscellaneous items 839 11 kv weasel covered conductor with accessories 840 11 kv rabbit covered conductor with accessories 841 33 kv dog covered conductor with accessories 842 shear bolted tusker terminal connector on ht side 843 shear bolted tusker terminal connector on lt side 844 shear head bolted lugs ( 630 sqmm ) 845 shear head bolted lugs ( 400 sqmm ) 846 aluminium lug long barrel off size 847 ms nut & bolts 848 plinth of distribution transformer ( 215 kva to 630 kva ) with frp fencing 849 sign board of size 6x4 sqfeet, mounting angels, excavation, cement concreting, foundation, painting etc. 850 sign board of size 1x1 sqfeet with pole mounting clamp, painting etc. 851 stay set ( galvanised ) with 50x8 mm stay clamps, guy insulator , anchor plate ( 200x200x6mm ) , nut bolts, 1 nos turn buckle, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work including foundation of stay support in each stay set as per scope of works 852 stay rod 16x1800 mm complete as per technical specification, scope of work and tender drawing 853 stay wire 7 / 10 swg 854 stay clamp ( flat 50x8 mm ) ( weight 1.5 kg ) with bolts and nuts 855 stay guy insulator lt 856 stay guy insulator ht ( 11 kv ) 857 stay thimble 858 hellically formed end fitting 859 concreting of stay road ( 0.2 cmt cement concreting in mixture ( 1:2:4 ) 860 stay set ( galvanised ) with 50x8 mm stay clamps, guy insulator , anchor plate ( 300x300x8mm ) , nut bolts, 1 nos turn buckle, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work including foundation of stay support in each stay set as per scope of works 861 stay rod 20x1800 mm complete as per technical specification, scope of work and tender drawing 862 stay wire 7 / 8 swg 863 stay clamp ( flat 50x8 mm ) ( weight 1.8 kg ) with bolts and nuts 864 stay guy insulator for 33kv line 865 stay thimble 866 hellically formed end fitting 867 concreting of stay road ( 0.3 cmt cement concreting in mixture ( 1:2:4 ) ...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

32369430 development of distribution infrastructure of packagegorakhpur at gorakhpur, deoria, maharajganj and kushinagar district of puvvnluttar pradeshunderrevamped reforms based and results linked, distribution sector scheme 1 supply of consumer service cable 2 supply of armored service cable for consumer service connection with all accessories including gi pipe / ms angle as per technical specifications, scope of works and approved drawings 3 supply of single phase armored al cable size 2cx 6 sq mm 4 supply of three phase armored al cable size 4cx 16 sq mm 5 supply of 10 swg gi wire 6 supply of 8 swg gi wire 7 conversion of existing lt lines on bare conductor to areal bunch xlpe cable 8 conversion of existing lt lines with bare conductor to ab xlpe cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 9 supply of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 10 galvanized stay set for lt line with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, 01 no. stay guy insulator, nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 11 conversion of existing lt lines using new earthing as per approved drawings, technical specifications and scope of work 12 supply of spike earthing made of 20mm x 2500 mm gi solid rod 13 supply of 8 swg gi wire for earthing and guarding 14 supply of following lt ab xlpe cable for conversion of existing lt bare conductor line with ab xlpe cable as required as per technical specification, approved drawings and scope of work: 15 supply of aerial bunchedxlpe cable 3 x 50 sqmm+1x35 sqmm. ( bare messenger wire ) +1x16 sqmm. 16 supply of aerial bunchedxlpe cable 3 x 70 sqmm.+1x50 sqmm. ( bare messenger wire ) +1x16 sqmm. 17 supply of aerial bunchedxlpe cable 3 x 95 sqmm.+1x70 sqmm. ( bare messenger wire ) + 1x16 sqmm. 18 supply of aerial bunchedxlpe cable 3 x 120 sqmm. + 1x95 sqmm. ( bare messenger wire ) +1x16 sqmm. 19 supply of aerial bunchedxlpe cable 3 x 150 sqmm. + 1x120 sqmm. ( bare messenger wire ) +1x16 sqmm. 20 supply of pole mounted lt distribution box as per approved drawings, technical specifications and scope of work 21 supply of three phase smc distribution box with clamps 22 supply of single phase smc distribution box with clamps 23 supply of xlpe insulated al. cable for energisation of distribution box / kiosk as per approved drawings, technical specifications and scope of work 24 supply of 1x25 mm2 xlpe insulated al.cable 25 supply of stone pad ( 300x300x75 ) 26 supply of accessories for ab xlpe cable as per approved drawings, technical specifications and scope of work 27 stainless steel strap 28 hdg lt pole clamp with nut & bolt for laying abc 29 dead end clamp with i hook ( insulated ) 30 suspension clamp with i hook ( insulated ) 31 95 / 35 sqmm 70 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 32 120 / 50 sqmm 95 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 33 lt insulation piercing connector 150 50 sqmm 50 25 sqmm size ( for energizing distribution box ) 34 lt insulation piercing connector 150 50 sqmm 150 50 sqmm size ( for line to line jumpering ) 35 lt insulation piercing connector 16 25sqmmsize suitable for street light connection 36 pre insulated compression connectors size 16 sqmm suitable for ab xlpe cable 37 pre insulated compression connectors size 50 sqmm suitable for ab xlpe cable 38 pre insulated compression connectors size 70 sqmm suitable for ab xlpe cable 39 pre insulated compression connectors size 95 sqmm suitable for ab xlpe cable 40 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 41 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 42 heat shrinkable type end cap for ab xlpe cable 43 supply for augmentation of lines 44 supply for augmentation of 33 kv line 45 supply for augmentation of 3 phase 33 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 46 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 47 supply new pre fabricated hot dip galvanized steel item, for augmentation of 33 kv line, like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 48 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work. 49 supply of pole accessories as per technical specification, approved drawing and scope of work 50 supply of 33 kv danger board 51 supply of gi barbed wire 12 swg 52 supply for augmentation of 3 phase 33 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material, aluminum tape and helical preformed fittings etc as required as per technical specification, approved drawings and scope of work. 53 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 54 supply of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 55 supply of 33 kv under ground cable as per technical specification, approved drawings and scope of work. 56 supply of 3cx300 sqmm 33 kv xlpe armored cable 57 supply of accessories for 33 kv3cx300 sqmm xlpe armored cable ( 2 nos including one spare ) like 160mm dia hdpe pipes for road crossing and 150 mm dia gi pipegrade b for pole support outdoor heat shrinkable cable jointing kits, lugs, cablepath markers, bi metallic clamps and 7 / 20 gi wire as per technical specification, approved drawing and scope of work 58 supplyof new insulator and hardware for augmentation of33 kv line as per technical specification, approved drawings and scope of work 59 supply of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 60 supply of 33 kv 10 kn polymer pin insulators 61 supply of new earthing arrangement for augmentation of33 kv line as per technical specifications, approved drawings and scope of work. 62 8 swg gi coil 115 turns ( 1.85 kg ) 63 supply of new stay set ( galvanized ) for 33 kv line with 50x8 mm stay clamp, 02 no. guy insulator, anchor plate ( 300x300x8mm ) , nut bolts, 01 no. turn buckles, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 64 supply of new gi wire for earthing and guarding for augmentation of33 kv line as per technical specification, approved drawings and scope of work. 65 supply of 6 swg gi wire 66 supply of 8 swg gi wire 67 supply of conductor accessories as per technical specification, approved drawing and scope of work 68 supply of pg clamp for dog to dog conductor 69 supply of pg clamp for panther to panther conductor 70 supply for augmentation of 11 kv lines 71 supply for augmentation of 3 phase 11 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 72 supply of 8.5 meter long / 180 kg pcc poles ( pcc pole as per state practice ) 73 supply for augmentation of 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms flats pole extension channel with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 74 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work. 75 supply of pole accessories as per technical specification, approved drawing and scope of work 76 supply of 11 kv danger board 77 stone pad ( 300x300x75mm ) 78 supply of gi barbed wire 12 swg 79 supply for augmentation of 3 phase 11 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. 80 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 81 supply of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 82 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 83 supply for augmentation of 3 phase 11 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 84 supply of 11 kv 45 kn polymer disc insulator along with suitable hardware fittings 85 supply of 11 kv 5 kn polymer pin insulators 86 supply for augmentation of 3 phase 11 kv line using new earthing arrangement as per technical specifications, approved drawings and scope of work. 87 supply of gi earthing spike made of 20x2500mm solid rod 88 supply for augmentation of 3 phase 11 kv line using new stay set ( galvanized ) with 50x8 mm stay clamp, 01 no. guy insulator, anchor plate ( 200x200x6mm ) , nut bolts, 1 no turn buckles, 1.8 m long 16 mm diameter solid gi stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 89 supply for augmentation of 3 phase 11 kv line using new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 90 supply of 6 swg gi wire 91 supply of 8 swg gi wire 92 supply of conductor accessories as per technical specification, approved drawing and scope of work 93 supply of pg clamp for weasel to weasel conductor 94 supply of pg clamp for dog to dog conductor 95 supply of pg clamp for rabbit to rabbit conductor 96 installation of dt capacitor 97 supply of dt capacitor with fitting as per technical specification, approved drawing and scope of work 98 supply of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 99 supply of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 100 supply of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 101 supply of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 102 supply of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 103 supply of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 104 erection part 105 installation of consumer service cable 106 installation of armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings 107 installation of single phase armored al cable size 2cx 6 sq mm 108 installation of three phase armored al cable size 4cx 16 sq mm 109 gi wire 8 swg 110 gi wire 10 swg 111 erection for conversion of existing lt lines on bare conductor to aerial bunch xlpe cable 112 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil of following pole as per scope of work, approved drawings and specifications: 113 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 114 erection of following types of poles for lt overhead line with stone pad, pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 115 erection of 8.5 m / 180 kgs pcc poles with base stone pad as required ( state practices of pcc pole and stone pad to be used ) 116 excavation of lt stay pit in following type of soils, as per scope of work, approved drawings and specifications: 117 normal soil 118 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) with all accessories as per technical specifications, approved drawings and scope of works. 119 removal of existing lt bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched xlpe cable, fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, pre insulated compression connectors, 16 mm dia ms nuts & bolts, pole clamps, stainless steel strap, single and three phase pole mounted distribution board, energisation of distribution box through 1x25 sqmm xlpe cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: 120 erection of aerial bunched xlpe cable3 x 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm 121 erection of aerial bunched xlpe cable 3 x 70 sqmm +1x50 sqmm ( bare messenger cum neutral ) +1x16 sqmm 122 erection of aerial bunched xlpe cable 3 x 95 sqmm +1x70 sqmm ( bare messenger cum neutral ) + 1x16 sqmm 123 erection of aerial bunched xlpe cable 3 x 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm 124 erection of aerial bunched xlpe cable 3 x 150 sqmm+ 1x120 sqmm ( bare messenger cum neutral ) +1x16 sqmm 125 erection, testing & commissioning of earthing by inserting gi earthing spike made of 20mm solid rod as per approved drawings, scope of work and technical specifications 126 erection of 8 swg gi wire for earthing by providing gi nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications 127 erection for augmentation of lines 128 erection for augmentation of 33 kv line 129 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 130 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 131 erection of following types of additional poles matching with existing line supports by installing danger plate, anti climbing devices ( barbed wire ) , red oxide & aluminum painting including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 132 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 133 excavation of stay pit for 33 kv stay in following type of soils, as per scope of work, approved drawings and specifications: 134 normal soil 135 erection of complete stay set with gi stay wire ( 7x4.00 mm dia ) , binding of stay wire, guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) with all accessories as per technical specifications, approved drawings and scope of works. 136 erection, testing and commissioning of 33 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 137 erection of 33 kv 10 kn pin insulator with gi pin 138 erection of 33 kv 70 kn disc insulator with strain hardware ( set of 3, 11 kv disc insulators ) 139 erection, testing & commissioning of new pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. 140 dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store and laying out & stringing of new acsr conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. 141 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 142 stringing of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 143 erection, testing & commissioning of 33 kvunder ground cable by2 nos ( including one spare ) 3cx300 sqmm xlpe armored cable, using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering, etc as required as per technical specifications, approved drawings and scope of he work. 144 erection for augmentation of 3 phase 33 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 145 erection of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 146 erection of 33 kv 10 kn polymer pin insulators 147 erection, testing & commissioning of earthing as per technical specifications, approved drawings and scope of work. 148 8 swg gi coil 115 turns ( 1.85 kg ) 149 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 150 erection of 6 swg gi wire 151 erection of 8 swg gi wire 152 erection for augmentation of 11 kv lines 153 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 154 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 155 erection of following types of poles for 11 kv overhead line byinstalling danger plate, anti climbing devices ( barbed wire ) , pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 156 erection of 8.5 m / 180 kgs pcc poles withbase stone pad ( state practices of pcc pole and base plate / stone to be used ) 157 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 158 normal soil 159 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) with all accessories as per technical specifications, approved drawings and scope of works. 160 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 161 erection of 11 kv pin insulator with gi pin 162 erection of 11 kv disc insulator with strain hardware 163 dismantling of existing overhead line conductor & fittings and depositing to employers store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 164 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 165 stringing of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 166 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 167 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and hdg ms nuts, bolts & washers as per technical specification, approved drawings and scope of work. 168 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 169 erection of 5 kn 11 kv polymer pin insulator 170 erection of 45 kn 11 kv polymer disc insulator with strain hardware 171 earthingand guarding arrangement as per technical specifications, approved drawings and scope of work. 172 erection, testing & commissioning of spike earthing 20mm solid rod 173 erection of 8 swg gi wire for earthing and guarding 174 erection of 6 swg gi wire for earthing and guarding 175 erection of dt capacitor 176 erection, testing & commissioning offollowing 440 volt lt shunt capacitor including mounting structure and accessories as required as per technical specifications, approved drawings and scope of work. 177 erection of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 178 erection of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 179 erection of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 180 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 181 erection of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 182 erection of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 183 words...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

32369261 development of distribution infrastructure of packagevaranasi 2 at jaunpur, ghazipur and chandauli district of puvvnluttar pradeshunderrevamped reforms based and results linked, distribution sector scheme 1 supply of consumer service cable 2 supply of armored service cable for consumer service connection with all accessories including gi pipe / ms angle as per technical specifications, scope of works and approved drawings 3 supply of single phase armored al cable size 2cx 6 sq mm 4 supply of three phase armored al cable size 4cx 16 sq mm 5 supply of 10 swg gi wire 6 supply of 8 swg gi wire 7 conversion of existing lt lines on bare conductor to areal bunch xlpe cable 8 conversion of existing lt lines with bare conductor to ab xlpe cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 9 supply of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 10 galvanized stay set for lt line with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, 01 no. stay guy insulator, nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 11 conversion of existing lt lines using new earthing as per approved drawings, technical specifications and scope of work 12 supply of spike earthing made of 20mm x 2500 mm gi solid rod 13 supply of 8 swg gi wire for earthing and guarding 14 supply of following lt ab xlpe cable for conversion of existing lt bare conductor line with ab xlpe cable as required as per technical specification, approved drawings and scope of work: 15 supply of aerial bunchedxlpe cable 3 x 50 sqmm+1x35 sqmm. ( bare messenger wire ) +1x16 sqmm. 16 supply of aerial bunchedxlpe cable 3 x 70 sqmm.+1x50 sqmm. ( bare messenger wire ) +1x16 sqmm. 17 supply of aerial bunchedxlpe cable 3 x 95 sqmm.+1x70 sqmm. ( bare messenger wire ) + 1x16 sqmm. 18 supply of aerial bunchedxlpe cable 3 x 120 sqmm. + 1x95 sqmm. ( bare messenger wire ) +1x16 sqmm. 19 supply of pole mounted lt distribution box as per approved drawings, technical specifications and scope of work 20 supply of three phase smc distribution box with clamps 21 supply of single phase smc distribution box with clamps 22 supply of xlpe insulated al. cable for energisation of distribution box / kiosk as per approved drawings, technical specifications and scope of work 23 supply of 1x25 mm2 xlpe insulated al.cable 24 supply of stone pad ( 300x300x75 ) 25 supply of accessories for ab xlpe cable as per approved drawings, technical specifications and scope of work 26 stainless steel strap 27 hdg lt pole clamp with nut & bolt for laying abc 28 dead end clamp with i hook ( insulated ) 29 suspension clamp with i hook ( insulated ) 30 95 / 35 sqmm 70 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 31 120 / 50 sqmm 95 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 32 lt insulation piercing connector 120 50 sqmm 50 25 sqmm size ( for energizing distribution box ) 33 lt insulation piercing connector 120 50 sqmm 120 50 sqmm size ( for line to line jumpering ) 34 lt insulation piercing connector 16 25sqmmsize suitable for street light connection 35 pre insulated compression connectors size 16 sqmm suitable for ab xlpe cable 36 pre insulated compression connectors size 50 sqmm suitable for ab xlpe cable 37 pre insulated compression connectors size 70 sqmm suitable for ab xlpe cable 38 pre insulated compression connectors size 95 sqmm suitable for ab xlpe cable 39 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 40 heat shrinkable type end cap for ab xlpe cable 41 supply for augmentation of lines 42 supply for augmentation of 33 kv line 43 supply for augmentation of 3 phase 33 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 44 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 45 supply new pre fabricated hot dip galvanized steel item, for augmentation of 33 kv line, like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 46 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work. 47 supply of pole accessories as per technical specification, approved drawing and scope of work 48 supply of 33 kv danger board 49 supply of gi barbed wire 12 swg 50 supply for augmentation of 3 phase 33 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material, aluminum tape and helical preformed fittings etc as required as per technical specification, approved drawings and scope of work. 51 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 52 supply of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 53 supply of 33 kv under ground cable as per technical specification, approved drawings and scope of work. 54 supply of 3cx300 sqmm 33 kv xlpe armored cable 55 supply of accessories for 33 kv3cx300 sqmm xlpe armored cable ( 2 nos including one spare ) like 160mm dia hdpe pipes for road crossing and 150 mm dia gi pipegrade b for pole support outdoor heat shrinkable cable jointing kits, lugs, cablepath markers, bi metallic clamps and 7 / 20 gi wireas per technical specification, approved drawing and scope of work 56 supplyof new insulator and hardware for augmentation of33 kv line as per technical specification, approved drawings and scope of work 57 supply of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 58 supply of 33 kv 10 kn polymer pin insulators 59 supply of new earthing arrangement for augmentation of33 kv line as per technical specifications, approved drawings and scope of work. 60 8 swg gi coil 115 turns ( 1.85 kg ) 61 supply of new stay set ( galvanized ) for 33 kv line with 50x8 mm stay clamp, 02 no. guy insulator, anchor plate ( 300x300x8mm ) , nut bolts, 01 no. turn buckles, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 62 supply of new gi wire for earthing and guarding for augmentation of33 kv line as per technical specification, approved drawings and scope of work. 63 supply of 6 swg gi wire 64 supply of 8 swg gi wire 65 supply of conductor accessories as per technical specification, approved drawing and scope of work 66 supply of pg clamp for dog to dog conductor 67 supply of pg clamp for panther to panther conductor 68 supply for augmentation of 11 kv lines 69 supply for augmentation of 3 phase 11 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 70 supply of 8.5 meter long / 180 kg pcc poles ( pcc pole as per state practice ) 71 supply for augmentation of 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms flats pole extension channel with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 72 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 73 supply of pole accessories as per technical specification, approved drawing and scope of work 74 supply of 11 kv danger board 75 stone pad ( 300x300x75mm ) 76 supply of gi barbed wire 12 swg 77 supply for augmentation of 3 phase 11 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. 78 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 79 supply of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 80 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 81 supply for augmentation of 3 phase 11 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 82 supply of 11 kv 45 kn polymer disc insulator along with suitable hardware fittings 83 supply of 11 kv 5 kn polymer pin insulators 84 supply for augmentation of 3 phase 11 kv line using new earthing arrangement as per technical specifications, approved drawings and scope of work. 85 supply of gi earthing spike made of 20x2500mm solid rod 86 supply for augmentation of 3 phase 11 kv line using new stay set ( galvanized ) with 50x8 mm stay clamp, 01 no. guy insulator, anchor plate ( 200x200x6mm ) , nut bolts, 1 no turn buckles, 1.8 m long 16 mm diameter solid gi stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 87 supply for augmentation of 3 phase 11 kv line using new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 88 supply of 6 swg gi wire 89 supply of 8 swg gi wire 90 supply of conductor accessories as per technical specification, approved drawing and scope of work 91 supply of pg clamp for weasel to weasel conductor 92 supply of pg clamp for dog to dog conductor 93 supply of pg clamp for rabbit to rabbit conductor 94 installation of dt capacitor 95 supply of dt capacitor with fitting as per technical specification, approved drawing and scope of work 96 supply of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 97 supply of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 98 supply of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 99 erection part 100 installation of consumer service cable 101 installation of armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings 102 installation of single phase armored al cable size 2cx 6 sq mm 103 installation of three phase armored al cable size 4cx 16 sq mm 104 gi wire 8 swg 105 gi wire 10 swg 106 erection for conversion of existing lt lines on bare conductor to aerial bunch xlpe cable 107 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil of following pole as per scope of work, approved drawings and specifications: 108 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 109 erection of following types of poles for lt overhead line with stone pad, pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 110 erection of 8.5 m / 180 kgs pcc poles with base stone pad as required ( state practices of pcc pole and stone pad to be used ) 111 excavation of lt stay pit in following type of soils, as per scope of work, approved drawings and specifications: 112 normal soil 113 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) with all accessories as per technical specifications, approved drawings and scope of works. 114 removal of existing lt bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched xlpe cable, fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, pre insulated compression connectors, 16 mm dia ms nuts & bolts, pole clamps, stainless steel strap, single and three phase pole mounted distribution board, energisation of distribution box through 1x25 sqmm xlpe cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: 115 erection of aerial bunched xlpe cable3 x 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm 116 erection of aerial bunched xlpe cable 3 x 70 sqmm +1x50 sqmm ( bare messenger cum neutral ) +1x16 sqmm 117 erection of aerial bunched xlpe cable 3 x 95 sqmm +1x70 sqmm ( bare messenger cum neutral ) + 1x16 sqmm 118 erection of aerial bunched xlpe cable 3 x 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm 119 erection, testing & commissioning of earthing by inserting gi earthing spike made of 20mm solid rod as per approved drawings, scope of work and technical specifications 120 erection of 8 swg gi wire for earthing by providing gi nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications 121 erection for augmentation of lines 122 erection for augmentation of 33 kv line 123 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 124 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 125 erection of following types of additional poles matching with existing line supports by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminum paint including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 126 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 127 excavation of stay pit for 33 kv stay in following type of soils, as per scope of work, approved drawings and specifications: 128 normal soil 129 erection of complete stay set with gi stay wire ( 7x4.00 mm dia ) , binding of stay wire, guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) with all accessories as per technical specifications, approved drawings and scope of works. 130 erection, testing and commissioning of 33 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 131 erection of 33 kv 10 kn pin insulator with gi pin 132 erection of 33 kv 70 kn disc insulator with strain hardware ( set of 3, 11 kv disc insulators ) 133 erection, testing & commissioning of new pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. 134 dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store and laying out & stringing of new acsr conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. 135 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 136 stringing of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 137 erection, testing & commissioning of 33 kvunder ground cable by2 nos ( including one spare ) 3cx300 sqmm xlpe armored cable, using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering and 7 / 20 gi wire etc as required as per technical specifications, approved drawings and scope of he work. 138 erection for augmentation of 3 phase 33 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 139 erection of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 140 erection of 33 kv 10 kn polymer pin insulators 141 erection, testing & commissioning of earthing as per technical specifications, approved drawings and scope of work. 142 8 swg gi coil 115 turns ( 1.85 kg ) 143 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 144 erection of 6 swg gi wire 145 erection of 8 swg gi wire 146 erection for augmentation of 11 kv lines 147 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 148 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 149 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 150 erection of 8.5 m / 180 kgs pcc poles withbase stone pad ( state practices of pcc pole and base plate / stone to be used ) 151 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 152 normal soil 153 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) with all accessories as per technical specifications, approved drawings and scope of works. 154 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 155 erection of 11 kv pin insulator with gi pin 156 erection of 11 kv disc insulator with strain hardware 157 dismantling of existing overhead line conductor & fittings and depositing to employers store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 158 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 159 stringing of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 160 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 161 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and hdg ms nuts, bolts & washers as per technical specification, approved drawings and scope of work. 162 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 163 erection of 5 kn 11 kv polymer pin insulator 164 erection of 45 kn 11 kv polymer disc insulator with strain hardware 165 earthingand guarding arrangement as per technical specifications, approved drawings and scope of work. 166 erection, testing & commissioning of spike earthing 20mm solid rod 167 erection of 8 swg gi wire for earthing and guarding 168 erection of 6 swg gi wire for earthing and guarding 169 erection of dt capacitor 170 erection, testing & commissioning offollowing 440 volt lt shunt capacitor including mounting structure and accessories as required as per technical specifications, approved drawings and scope of work. 171 erection of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 172 erection of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 173 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 174 words...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

32319297 development of distribution infrastructure of package varanasi 1 at varanasi district of puvvnluttar pradesh under revamped reforms based and results linked, distribution sector scheme= 1 supply of consumer service cable 2 supply of armored service cable for consumer service connection with accessories as per technical specifications, scope of works and approved drawings 3 supply of single phase armored al cable size 2cx 6 sq mm 4 supply of three phase armored al cable size 4cx 16 sq mm 5 supply of 10 swg gi wire 6 supply of 8 swg gi wire 7 conversion of existing lt lines on bare conductor to areal bunch xlpe cable 8 conversion of existing lt lines with bare conductor to ab xlpe cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 9 supply of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 10 galvanized stay set for lt line with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, stay guy insulator, nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 11 conversion of existing lt lines using new earthing as per approved drawings, technical specifications and scope of work 12 supply of spike earthing made of 20mm x 2500 mm gi solid rod 13 supply of 8 swg gi wire for earthing and guarding 14 supply of following lt ab xlpe cable for conversion of existing lt bare conductor line with ab xlpe cable as required as per technical specification, approved drawings and scope of work: 15 supply of aerial bunchedxlpe cable 3 x 50 sqmm+1x35 sqmm. ( bare messenger wire ) +1x16 sqmm. 16 supply of aerial bunchedxlpe cable 3 x 70 sqmm.+1x50 sqmm. ( bare messenger wire ) +1x16 sqmm. 17 supply of aerial bunchedxlpe cable 3 x 95 sqmm.+1x70 sqmm. ( bare messenger wire ) + 1x16 sqmm. 18 supply of aerial bunchedxlpe cable 3 x 120 sqmm. + 1x95 sqmm. ( bare messenger wire ) +1x16 sqmm. 19 supply of pole mounted lt distribution box as per approved drawings, technical specifications and scope of work 20 supply of three phase smc distribution box with clamps 21 supply of single phase smc distribution box with clamps 22 supply of xlpe insulated al. cable for energisation of distribution box / kiosk as per approved drawings, technical specifications and scope of work 23 supply of 1x25 mm2 xlpe insulated al.cable 24 supply of stone pad ( 300x300x75 ) 25 supply of accessories for ab xlpe cable as per approved drawings, technical specifications and scope of work 26 stainless steel strap 27 hdg lt pole clamp with nut & bolt for laying abc 28 dead end clamp with i hook ( insulated ) 29 suspension clamp with i hook ( insulated ) 30 95 / 35 sqmm 70 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 31 120 / 50 sqmm 95 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 32 lt insulation piercing connector 120 50 sqmm 50 25 sqmm size ( for energizing distribution box ) 33 lt insulation piercing connector 120 50 sqmm 120 50 sqmm size ( for line to line jumpering ) 34 lt insulation piercing connector 16 25sqmmsize suitable for street light connection 35 pre insulated compression connectors size 16 sqmm suitable for ab xlpe cable 36 pre insulated compression connectors size 50 sqmm suitable for ab xlpe cable 37 pre insulated compression connectors size 70 sqmm suitable for ab xlpe cable 38 pre insulated compression connectors size 95 sqmm suitable for ab xlpe cable 39 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 40 heat shrinkable type end cap for ab xlpe cable 41 supply of new 11 kv lines : feeder segregation ( agriculture feeder ) 42 supply of support for 11 kv overhead line as per technical specification, approved drawings and scope of work 43 supply of 8.5m / 180 kgs pcc poles ( pcc pole as per state practice ) 44 supply for 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms transformer base channel, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 45 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 46 supply of pole accessories as per technical specification, approved drawing and scope of work 47 supply of 11 kv danger board 48 supply of stone pad 300x300x75 49 supply of barbed gi wire 12 swg 50 supply of stay set ( galvanized ) with 50x8 mm stay clamp, stay insulator ( 1 nos. ) , anchor plate ( 200x200x6 ) , nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 51 supply of insulator and hardware as per technical specification, approved drawings and scope of work. 52 supply of 11 kv45 kn polymer disc insulator along with suitable hardware fittings 53 supply of 11 kv 5 kn polymer pin insulators 54 supply of earthing arrangement as per technical specifications, approved drawings and scope of work. 55 supply of spike earthing 20mm x 2500 mm solid rod 56 supply of 8 swg gi wire for earthing and guarding 57 supply of 6 swg gi wire for earthing and guarding 58 supply of acsr conductors of following sizes with jointing sleeves, binding materials, pg clamps, bi metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work 59 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 60 supply of 11 kv, 600a, 3 ph, 3 pin type, vertical mounting type, gang operated, ab switch along with support insulators, base channel down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 61 supply of 12 kv 3ph indoor type switch gear and 11 kv xlpe cable as per technical specifications, approved drawings and scope of works: 62 supply of indoor type 12 kv 3 ph 1250 a vcb with control and protection system for out going feeder consisting ofct, a meter, volt meter, relays, energy meter ( tvm ) dlms compliant & accessories complete as per specifications for feeder breaker protection 63 11 kv 3x 185 sqmm xlpe armored power cable, aluminum stranded conductor, including their termination materials like indoor and outdoor termination kit, glands, lugs, tagging, cable path marker etc as required as per technical specifications, approved drawings and scope of the works. 64 supply for augmentation of lines 65 supply for augmentation of 33 kv line 66 supply for augmentation of 3 phase 33 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 67 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 68 supply new pre fabricated hot dip galvanized steel item, for augmentation of 33 kv line, like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 69 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work. 70 supply of pole accessories as per technical specification, approved drawing and scope of work 71 supply of 33 kv danger board 72 supply of gi barbed wire 12 swg 73 supply for augmentation of 3 phase 33 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material, aluminum tape and helical preformed fittings etc as required as per technical specification, approved drawings and scope of work. 74 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 75 supply of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 76 supply of 33 kv under ground cable as per technical specification, approved drawings and scope of work. 77 supply of 3cx300 sqmm 33 kv xlpe armored cable 78 supply of accessories for 33 kv3cx300 sqmm xlpe armored cable ( 2 nos including one spare ) , like 160mm dia hdpe pipes for road crossing and 150 mm dia gi pipegrade b for pole support outdoor heat shrinkable cable jointing kits, lugs, cablepath markers, bi metallic clamps, 7 / 20 gi wireas per technical specification, approved drawing and scope of work 79 supplyof new insulator and hardware for augmentation of33 kv line as per technical specification, approved drawings and scope of work 80 supply of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 81 supply of 33 kv 10 kn polymer pin insulators 82 supply of new earthing arrangement for augmentation of33 kv line as per technical specifications, approved drawings and scope of work. 83 8 swg gi coil 115 turns ( 1.85 kg ) 84 supply of new stay set ( galvanized ) for 33 kv line with 50x8 mm stay clamp, guy insulator, anchor plate ( 300x300x8mm ) , nut bolts, turn buckles, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 85 supply of new gi wire for earthing and guarding for augmentation of33 kv line as per technical specification, approved drawings and scope of work. 86 supply of 6 swg gi wire 87 supply of 8 swg gi wire 88 supply of conductor accessories as per technical specification, approved drawing and scope of work 89 supply of pg clamp for dog to dog conductor 90 supply of pg clamp for panther to panther conductor 91 supply for augmentation of 11 kv lines 92 supply for augmentation of 3 phase 11 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 93 supply of 8.5 meter long / 180 kg pcc poles ( pcc pole as per state practice ) 94 supply for augmentation of 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 95 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc.as per technical specification, approved drawings and scope of work. 96 supply of pole accessories as per technical specification, approved drawing and scope of work 97 supply of 11 kv danger board 98 stone pad ( 300x300x75mm ) 99 supply of gi barbed wire 12 swg 100 supply for augmentation of 3 phase 11 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. 101 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 102 supply of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 103 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 104 supply for augmentation of 3 phase 11 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 105 supply of 11 kv 45 kn polymer disc insulator along with suitable hardware fittings 106 supply of 11 kv 5 kn polymer pin insulators 107 supply for augmentation of 3 phase 11 kv line using new earthing arrangement as per technical specifications, approved drawings and scope of work. 108 supply of gi earthing spike made of 20x2500mm solid rod 109 supply for augmentation of 3 phase 11 kv line using new stay set ( galvanized ) with 50x8 mm stay clamp, guy insulator, anchor plate ( 200x200x6mm ) , nut bolts, 1 no turn buckles, 1.8 m long 16 mm diameter solid gi stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 110 supply for augmentation of 3 phase 11 kv line using new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 111 supply of 6 swg gi wire 112 supply of 8 swg gi wire 113 supply of conductor accessories as per technical specification, approved drawing and scope of work 114 supply of pg clamp for weasel to weasel conductor 115 supply of pg clamp for dog to dog conductor 116 supply of pg clamp for rabbit to rabbit conductor 117 installation of dt capacitor 118 supply of dt capacitor with fitting as per technical specification, approved drawing and scope of work 119 supply of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 120 supply of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 121 supply of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 122 supply of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 123 supply of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 124 supply of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 125 erection part 126 installation of consumer service cable 127 installation of armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings 128 installation of single phase armored al cable size 2cx 6 sq mm 129 installation of three phase armored al cable size 4cx 16 sq mm 130 gi wire 8 swg 131 gi wire 10 swg 132 erection for conversion of existing lt lines on bare conductor to aerial bunch xlpe cable 133 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil of following pole as per scope of work, approved drawings and specifications: 134 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 135 erection of following types of poles for lt overhead line with stone pad, pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 136 erection of 8.5 m / 180 kgs pcc poles with base stone pad as required ( state practices of pcc pole and stone pad to be used ) 137 excavation of lt stay pit in following type of soils, as per scope of work, approved drawings and specifications: 138 normal soil 139 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 140 removal of existing lt bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched xlpe cable, fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, pre insulated compression connectors, 16 mm dia ms nuts & bolts, pole clamps, stainless steel strap, single and three phase pole mounted distribution board, energisation of distribution box through 1x25 sqmm xlpe cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: 141 erection of aerial bunched xlpe cable3 x 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm 142 erection of aerial bunched xlpe cable 3 x 70 sqmm +1x50 sqmm ( bare messenger cum neutral ) +1x16 sqmm 143 erection of aerial bunched xlpe cable 3 x 95 sqmm +1x70 sqmm ( bare messenger cum neutral ) + 1x16 sqmm 144 erection of aerial bunched xlpe cable 3 x 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm 145 erection, testing & commissioning of earthing by inserting gi earthing spike made of 20mm solid rod as per approved drawings, scope of work and technical specifications 146 erection of 8 swg gi wire for earthing by providing gi nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications 147 erection, testing and commissioning of new 11 kv lines: feeder segregation ( agriculture feeder ) 148 survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of project manager 149 excavation of pole pit ( of depth 1 / 6th of pole length ) in normal soil for following type pole as per scope of work, approved drawings and specifications: 150 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 151 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminumto stp poles inluding paint, numberingof poleby paint including cement concrete foundation using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 152 erection of 8.5 m / 180 kgs pcc poles with base pad including cement concreting, ( state practices of pcc pole, stone to be used ) 153 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washersas per technical specification, approved drawings and scope of work. 154 earthing arrangement as per technical specifications, approved drawings and scope of work. 155 erection, testing & commissioning of spike earthing 20mm x 2500mm solid rod 156 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 157 normal soil 158 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 1 nos. ) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 159 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 160 erection of 5 kn 11 kv polymer pin insulator 161 erection of 45 kn 11 kv polymer disc insulator with strain hardware 162 laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 163 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 164 erection, testing and commissioning of vertical type 11 kvab switch along with support insulators, base channel, down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 165 erection of 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor typevacuum circuit breaker with adopter panel for out going feeder by leveling, alignment and welding on existing cable trench in control room. testing & commissioning of indoor vcb panel including 3 nos indoor type current transformer, a meter, volt meter, relay & accessories protection as per approved drawings, technical specifications and scope of the work.: 166 laying, erection, termination using indoor & outdoor termination kit, 11kv 3x 185 sqmm xlpearmored power cablesas per technical specifications, approved drawings and scope of works. : 167 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 168 erection of 6 swg gi wire 169 erection of 8 swg gi wire 170 extension of control room of 33 / 11 kv substation to accommodate vcb for new 11 kv feeders as per technical specification, approved drawing and scope of work. 171 design, engineering construction of control room building extension 300 sq feet including cost ofall materials, t&p and labour, etc. as per technical specification and approved drawing as per direction of employer 172 shifting of following distribution transformer along with fixture including dismantling , shifting and erection from one location to another location as per approved survey. 173 single phase transformer 174 three phase transformer 175 erection for augmentation of lines 176 erection for augmentation of 33 kv line 177 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 178 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 179 erection of following types of additional poles matching with existing line supports by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminum including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 180 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 181 excavation of stay pit for 33 kv stay in following type of soils, as per scope of work, approved drawings and specifications: 182 normal soil 183 erection of complete stay set with gi stay wire ( 7x4.00 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 184 erection, testing and commissioning of 33 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 185 erection of 33 kv 10 kn pin insulator with gi pin 186 erection of 33 kv 70 kn disc insulator with strain hardware ( set of 3, 11 kv disc insulators ) 187 erection, testing & commissioning of new pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. 188 dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store and laying out & stringing of new acsr conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. 189 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 190 stringing of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 191 erection, testing & commissioning of 33 kvunder ground cable by2 nos ( including one spare ) 3cx300 sqmm xlpe armored cable, using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering and 7 / 20 gi wire etc as required as per technical specifications, approved drawings and scope of he work. 192 erection for augmentation of 3 phase 33 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 193 erection of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 194 erection of 33 kv 10 kn polymer pin insulators 195 erection, testing & commissioning of earthing as per technical specifications, approved drawings and scope of work. 196 8 swg gi coil 115 turns ( 1.85 kg ) 197 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 198 erection of 6 swg gi wire 199 erection of 8 swg gi wire 200 erection for augmentation of 11 kv lines 201 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 202 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 203 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 204 erection of 8.5 m / 180 kgs pcc poles withbase stone pad ( state practices of pcc pole and base plate / stone to be used ) 205 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 206 normal soil 207 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 208 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 209 erection of 11 kv pin insulator with gi pin 210 erection of 11 kv disc insulator with strain hardware 211 dismantling of existing overhead line conductor & fittings and depositing to employers store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 212 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 213 stringing of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 214 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 215 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and hdg ms nuts, bolts & washers as per technical specification, approved drawings and scope of work. 216 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 217 erection of 5 kn 11 kv polymer pin insulator 218 erection of 45 kn 11 kv polymer disc insulator with strain hardware 219 earthingand guarding arrangement as per technical specifications, approved drawings and scope of work. 220 erection, testing & commissioning of spike earthing 20mm solid rod 221 erection of 8 swg gi wire for earthing and guarding 222 erection of 6 swg gi wire for earthing and guarding 223 erection of dt capacitor 224 erection, testing & commissioning offollowing 440 volt lt shunt capacitor including mounting structure and accessories as required as per technical specifications, approved drawings and scope of work. 225 erection of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 226 erection of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 227 erection of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 228 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 229 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 230 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 231 words...

Kanpur Electricity Supply Co Limited - Uttar Pradesh

32319032 revamped reforms based and results linked, distribution sector scheme infrastructure work under loss reduction in kesco, kanpur 1 supply of1.1_kv xlpe insulated pvc sheathed armoured aluminum cable in high loss area 2 2cx6 sqmm 3 2cx10 sqmm 4 4cx16 sqmm 5 4cx25 sqmm 6 supply of 9.5 m long steel tubular poles with welded steel base plate of designation 410 sp 37 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 7 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 8 supply of new galvanised stay set with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, stay guy insulator, nut bolts, 2 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 9 supply of spike earthing 2540mm longmade of 20mm gi solid rod. 10 supply of hot dip galvanized g.i. wire earthing coil 11 supply of 6 swg gi wire 12 supply of 8 swg gi wire 13 supply of aerial bunched xlpecable 3x95+1x70+1x16 sqmm 14 supply of aerial bunched xlpecable 3x120+1x70+1x16 sqmm 15 supply of aerial bunched xlpecable 3x150+1x120+1x16 sqmm 16 supply of lt pole clamps with nut & bolts for laying abc 17 supply of dead end clamps with eye hook ( insulated ) 18 supply of suspension clamps with eye hook ( insulated ) 19 supply of lt insulation piercing connectors of 25 150 sqmm size for energizing distribution kiosk / box 20 supply of lt insulation piercing connectors of 25 120sqmm size for energizing distribution kiosk / box 21 supply of lt insulation piercing connectors of 25 95sqmm size for energizing distribution kiosk / box 22 supply of l.t. neutral bare connector. 23 supply of 1x25 mm^2 xlpe / pvcinsulated al. cable for energising the distribution boxes / kiosk 24 supply of single phase distribution box with clamps with lug. 25 supply of three phase distribution box with clamps with lug. 26 supply of pre fabricated steel items like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, transformer mounting structure etc made of ms channels ( 100x50x6mm ) , ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) of given size duly galvanisedfor over head structures as per technical specification, approved drawings and scope of work. 27 supply ofms nuts, bolts with washers duly galvanised as per technical specification, approved drawings and scope of work ( off size ) . 28 supply of 11 kv polymer / porcelain disc insulator 70 kn along with suitable hardware fittings 29 supply of 11 kv polymer / porcelain pin insulators 10 kn with gi pin 30 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog 31 supply of ci packing ( galvanised ) as per site requirement. 32 supply ofdanger plate 33 supply ofg.i. barbed wire 34 supply of 12 kv, 1600 a, 350mva, 25ka for 3 seconds, 3 ph, indoor typevacuum circuit breaker along with 12 kv, 1 phase, 400 200 / 5 5 3 nos indoor type current transformer, indoor mounting type control panel for feeder protection, control cabling between vcb and indoor control panel ( scada compatible & 61850 protocol compliant protection relays ) and required accessories, bi metallic clamps, a meter, volt meter, 3 phase electronic energy meter, relay & accessories complete for feeder breaker protection along with adapter panel / complete mechanism to connect with existing busbaras per technical specifications, approved drawings and scope of works ( outgoing panel ) 35 supply of g.i. pipe 6 dia. with clamps etc. 36 supply of11kv xlpe 3 phase power cable armored, aluminium conductor, standard as per technical specification, approved drawing and scope of works 3cx185 sqmm 37 supply of heat shrinkable jointing kit outdoor / indoor for 11 kv 3x185 sq. mm xlpe cable 38 supply of heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 39 supply of heat shrinkable jointing kit indoor for 11 kv 3x185 sq. mm xlpe cable 40 supply of 11kv straight through joint 3x185 sqmm xlpe cable 41 supply of l.t aluminum armored xlpe single core cable size 42 1x630 sq mm. 43 1x400 sq mm. 44 supply of al crimping lugs ( 630 / 400 / ) sq mm. for all cables ofdistribution transformers ( any rating ) 45 supply of 1100 grade. pvc sheathed steel strip armored, aluminum conductorlt xlpe insulated cable size 46 3.5 cx240 sq mm. xlpe 47 3.5 cx120 sq mm. xlpe 48 3.5 cx70 sq mm. xlpe 49 supply of cable end termination using total double compersation brassglands and crimping type aluminum thimbles size for l.t. cables. 50 3.5 cx240 sq mm. xlpe 51 3.5 cx120 sq mm. xlpe 52 3.5 cx70 sq mm. xlpe 53 supply ofhdpe pipe 110 mm dia to be laid by horizontal drilling for under ground piping ( trenchless ) at road cross of above cable. 54 supply of gi pipe for external area of small cable to houses 55 50mm dia 56 40 mm dia 57 supply of pvc pipe heavy gauge 40 mm dia ( under ground area ) pipe for small cable to houses 58 supply of g.i. strip of size 25x3 sqmm for making connection between type b / c panel and earth rod 59 supply oftype lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubical should be weather proof, dust proof, bremen proof and in closer protection shall be ip 65 as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 2 mm crca sheet steel & provided with 2 mm hinged door including suitable foundation, main lt panel at substation 1000 & 630 kva ( type a 1 ) incomer 1 no. 1250 amp. tp mdo acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ( outgoing 4 sets of 400 amp. tp mccb with spreader & extended handle ) ( 2 sets of 250amp. tp mccb with spreader & extended handle ) ( 2 sets of 100 0amp. tp mccb with spreader & extended handle ) 60 supply of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubicle should be weather proof, dust proof, bremen proof and in closer protection shall be ip 65 as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 2 mm crca sheet steel & provided with 2 mm hinged door including suitable foundation, main lt panel at substation 400 kva ( type a 2 ) ( incomer 1 set of 800 amp.acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ( outgoing 6 sets of 250 amp. tp mccb with spreader & extended handle ( 5no.+1no. capacitor panel ) ) ( 2 sets of 100 amp. tp mccb with spreader & extended handle ) 61 supply of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubical should be weather proof, dust proof, bremen proof and in closer protection shall be ip 65 as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 2 mm crca sheet steel & provided with 2 mmhinged door including suitable foundation, main lt panel at substation 250 kva ( type a 3 ) ( incomer 1 set of 630 amp. acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ) ( outgoing 5 sets of 250 amp. tp mccb with spreader & extended handle ( 4no.+1no. capacitor panel ) ) ( 2 sets of 100 amp. tp mccb with spreader & extended handle ) 62 supply of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubical should be weather proof, dust proof, bremen proof and in closer protection shall be ip 65 as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 2 mm crca sheet steel & provided with 2 mm hinged door including suitable foundation, main lt panel at substation 160 kva ( type a 4 ) ( incomer 1 set of 400 amp. acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ( outgoing 4 sets of 250 amp. tp mccb with spreader & extended handle ( 3no.+1no. capacitor panel ) ) ( 2 sets of 100 amp. tp mccb with spreader & extended handle ) 63 supply of outdoor type feeder pillar panel to be made of 2mm. crca sheet & covers will be 2 mm crca sheet duly powder coated paint including suitable foundation with 400 amp. aluminum bus bar ( type b 1 ) with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) having : 1 no incomer 250amp. tp mccb and 6 no.out going 100 amp. tp mccb with spreader & extended handle. 64 supply of outdoor type feeder pillar panel to be made of 2mm. crca sheet & covers will be 2 mm crca sheet duly powder coated paint including suitable foundation with 300 amp. aluminum bus bar ( type b 2 ) with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) having :1 no incomer 250amp. tp mccb and 5 no.out going 100 amp. tp mccb spreader & extended handle. 65 supply of outdoor type feeder pillar panel to be made of 2mm. crca sheet & covers will be 2 mm crca sheet duly powder coated paint including suitable foundation with 300 amp. aluminum bus bar ( type b 3 ) with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) having :1 no incomer 250 amp. tp mccb and 4 no.out going 100amp. tp mccb spreader & extended handle. 66 supply of lockable distribution box along withbar lock of size 450x450mm including suitable foundation with bus baramp. 140tpn to feed up to 10 houses ( type c ) . panel to be made of 2mm. crca sheet 67 supplyof gi pipe of 40 mm dia under ground ( for street light ) 68 supply junction box on stp / pcc pole with 900 mm long gi pipe 25 mm dia with clamp ( for street light connection ) 69 supply ofgi pipe 40mm dia b class 40 feet longfor earthing of type a and b panels 70 supply of g.i . pipe chemical earthing ( electrode 3 mtr long 80 mm inner dia along with chemical powder ) 71 supply of g.i.strip of size 50x6mmfor connecting the panels a& b type panels. 72 supply of m.s flat of size 25x3mmfor connecting the panels c type panels. 73 supply of steel structure of size 65x65x6 mm ( m.s. angle ) 74 supply of single phase polycarbonate meter box 75 supply of three phase polycarbonate meter box 76 supply of 11 kvcapacitor bank including mounting steel galvanised structure and accessories as required as per detailed technical specifications, drawing and scope of works in following arrangements: 77 capacitor bank 1200 kvar auto type substation mounted with all associated equipment like 11 kv vcb along with adapter panel / complete mechanism for connection with existing busbar, c&r panel, cts, 11 kv 200a isolators with earth switch, rvt, 11 kv station class la, red oxide / aluminium painting, 2.5 sq.mm. pvc armoured stranded copper control cables, protection circuit and equipment, earthing, 16 mm dia ms nuts & bolts etc as required as per approved technical specifications, drawing and scope of works 78 capacitor bank 1500 kvar auto type substation mounted with all associated equipment like 11 kv vcb along with adapter panel / complete mechanism for connection with existing busbar, , c&r panel, cts, 11 kv 200a isolators with earth switch, rvt, 11 kv station class la, red oxide / aluminium painting, 2.5 sq.mm. pvc armoured stranded copper control cables, protection circuit and equipment, earthing, 16 mm dia ms nuts & bolts etc as required as per approved technical specifications, drawing and scope of works 79 supply of 11 kv acs dog covered conductor with all accessories. 80 erection part 81 armoured consumer cabling in high loss areas 82 erection / laying of 1.1_kv xlpe insulated pvc sheathed armoured aluminum cablefrom exisitng lt line / pole to consumer meter including proper lugging. 83 2cx6 sqmm 84 2cx10 sqmm 85 4cx16 sqmm 86 4cx25 sqmm 87 replacement of bare conductors / damaged a.b. cable with ab cables 88 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 89 9.5 m long steel tubular poles with welded steel base plate of designation 410 sp 37 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 90 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in soft rock / mettalic road / rcc / khranjaas per scope of work, approved drawings and specifications: 91 9.5 m long steel tubular poles with welded steel base plate of designation 410 sp 37 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 92 erection of following types of poles for lt overhead line by providing and installingred oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) or / and 200 mm average size bolders mixed with excavated earth etc as per scope of work, approved drawings and specifications: 93 9.5 m long steel tubular poles with welded steel base plate of designation 410 sp 37 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) cement concreting 0.5 cmt 94 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 95 normal soil 96 soft rock soil / soft rock / mettalic road / rcc / kharanja 97 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 2 nos. ) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6 ) as per technical specifications, approved drawings and scope of works. 98 dismantling / removal of existing lt bare conductor line or damaged a.b. cable & fixtures including damaged poles, depositing to stores of employer and erection, testing & commissioning of new aerial bunched xlpe cable, tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, 16 mm dia ms nuts & bolts, pole clamps, etc. as required as per technical specification, approved drawings and scope of work: 99 erection of aerial bunched xlpecable 3x95+1x70+1x16 sqmm with all assecessiories. 100 erection of aerial bunched xlpecable 3x120+1x70+1x16 sqmm with all assecessiories. 101 erection of aerial bunched xlpecable 3x150+1x120+1x16 sqmm with all assecessiories. 102 erection of single phase distribution box with clamps, lug and all accessories. 103 erection of three phase distribution box with clamps lug and all accessories. 104 erection, testing & commissioning of earthing by inserting gi earthing spike 2540 mm long made of 20mm solid rod as per approved drawings, scope of work and technical specifications 105 erection, testing & commissioning of earthing coil 106 erection of 6 swg gi wire for earthing by providing gi nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications 107 shifting of existing consumer connection from existing bare conductor line / damaged a.b. cable line to newly erected ab cable line 108 single phase connection 109 three phase connection 110 strengthening of existing damaged pole by providing and welding 1.2mtr long 3 no ms angle 65*65*6mm and carrying out required grouting and pole plinth activities as per approved drawing and technical specification. 111 11 kv feeder bifurcation by constructing 11 kv over head line 112 survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of project manager 113 excavation of pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 114 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 115 9.5 m long steel tubular poles with welded steel base plate of designation 410 sp 37 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 116 excavation of pole pit ( of depth 1 / 6th of pole length ) in soft rock / metallic road / rcc / kharanjaas per scope of work, approved drawings and specifications: 117 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 118 9.5 m long steel tubular poles with welded steel base plate of designation 410 sp 37 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 119 erection of following types of poles for 11 kv overhead line by providing and installing danger plate, anti climbing devices ( barbed wire ) , earthing material ( coil and 8swg gi wire ) , red oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) or / and 200 mm average size bolders mixed with excavated earth etc as per scope of work, approved drawings and specifications: 120 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) cement concreting 0.65 cmt 121 9.5 m long steel tubular poles with welded steel base plate of designation 410 sp 37 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) cement concreting 0.5 cmt 122 erection, testing & commissioning of pre fabricated steel items like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washers all ( galvanized ) including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work. 123 earthing arrangement as per technical specificatons, approved drawings and scope of work. 124 excavation, erection, testing & commissioning of spike earthing of 2540 mm long with 20mm solid rod 125 excavation, erection, testing & commissioning of earthing coil 126 erection of 8 swg gi wire for earthing and guarding by providing gi nut, bolts & washers, turn buckle etc 127 erection of 6 swg gi wire for earthing and guarding by providing gi nut, bolts & washers, turn buckle etc 128 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 129 normal soil 130 soft soil / soft rock / metallic road / rcc / khranja 131 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 2 nos. ) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6 ) as per technical specifications, approved drawings and scope of works. 132 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 133 11 kv pin insulator with gi pin 134 11 kv disc insulator 70kn with strain hardware 135 laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 136 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog 137 erection of 12 kv, 1600 a, 350mva, 25ka for 3 seconds, 3 ph, indoor typevacuum circuit breaker along with 12 kv, 1 phase, 400 200 / 5 5 3 nos indoor type current transformer, indoor mounting type control panel for feeder protection, control cabling between vcb and indoor control panel ( scada compatible & 61850 protocol compliant protection relays ) and required accessories, bi metallic clamps, a meter, volt meter, 3 phase electronic energy meter, relay & accessories complete for feeder breaker protection along with adapter panel / complete mechanism to connect with existing busbaras per technical specifications, approved drawings and scope of works . 138 11 kv feeder bifurcation by laying under ground cable 139 survey, route alignment & pole spotting and detection of existing electrical / telephonic cable / and other utilites of public utilites departments with the help of utilitiy dectector andpreparation of survey report and uploading in the web portal after approval of project manager. 140 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 141 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 142 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in soft rock / soft rock / mettalic road / rcc / khranjaas per scope of work, approved drawings and specifications: 143 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 144 erection of following types of poles for 11 kv overhead line by providing and installing danger plate, anti climbing devices ( barbed wire ) , earthing material ( coil and 8swg gi wire ) , red oxide & aluminium paint, pole numbering including cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) or / and 200 mm average size bolders mixed with excavated earth etc as per scope of work, approved drawings and specifications: 145 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) cement concreting 0.65 cmt 146 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 147 normal soil 148 soft rock soil / soft rock / mettalic road / rcc / khranja 149 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 2 nos. ) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6 ) as per technical specifications, approved drawings and scope of works. 150 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 151 11 kv pin insulator with gi pin 152 11 kv disc insulator 70kn with strain hardware 153 erection, testing & commissioning of pre fabricated steel items like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washers including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work. 154 earthing arrangement as per technical specificatons, approved drawings and scope of work. 155 excavation, erection, testing & commissioning of spike earthing of2540 mm long with 20mm solid rod 156 excavation, erection, testing & commissioning of earthing coil 157 erection of 8 swg gi wire for earthing and guarding by providing gi nut, bolts & washers, turn buckle etc 158 laying of 11kv cable through hdd method ( including cable length mounted upto pole top minus cable length laid inside g.i. pipe ) including digging of pit 159 digging of trench .6 mtr wide .9 mtr to 1.5 mtr deep for laying of pipe and cable 160 normal soil 161 soft rock / kharanja 162 hard rock / metallic road / rcc 163 laying of gi pipe 6 dia in above digged trench and also for raising cable on double pole / structure laying of 11 kv cable 3x185 sqmm 164 laying of 11 kv cable through above pipe 165 laying of cable in above digged trench and also mounting upto line by using bricks / sand &stone pad as per rec norms 166 making andmounting of heat shrinkable jointing kit outdoor / indoor for 11 kv 3x185 sqmm xlpe cable 167 digging suitable pit and making straight through and joint 11 kv 3x185 sqmm 168 making of straight through joint and construction of rb pit 3x1x1 mtr. with 9 inch thick side wall and 6 inch thick rcc bed along with rcc trench cover in three parts duly plastered and finsihed for housing st. through joint. box and filled with sand. 169 road restoration charges against thepermission from concerning department like nagar nigam, pwd, nhai etc 170 normal soil 171 soft rock / khranja 172 hard rock / metallic road / rcc 173 erection of 12 kv, 1600 a, 350mva, 25ka for 3 seconds, 3 ph, indoor typevacuum circuit breaker along with 12 kv, 1 phase, 400 200 / 5 5 3 nos indoor type current transformer, indoor mounting type control panel for feeder protection, control cabling between vcb and indoor control panel ( scada compatible & 61850 protocol compliant protection relays ) and required accessories, bi metallic clamps, a meter, volt meter, 3 phase electronic energy meter, relay & accessories complete for feeder breaker protection along with adapter panel / complete mechanism to connect with existing busbaras per technical specifications, approved drawings and scope of works . 174 conversion of exisiting lt bare conductor line into lt under ground network. 175 erection ofl.t aluminum armored xlpe single core cable 176 installation of l.t aluminum armored xlpe single core cable size 1x630 sq mm. 177 installation of l.t aluminum armored xlpe single core cable size 1x400 sq mm. 178 al crimping lugs ( 630 / 400 / 240 / 120 / 70 ) sq mm. 179 erectionof cable end termination using total double compersation brassglands and crimping type aluminum thimbles size 180 3.5 cx240 sq mm. xlpe 181 3.5 cx120 sq mm. xlpe 182 3.5 cx70 sq mm. xlpe 183 laying, testing and commissioning of 1100 volts grade, pvc sheathed steel strip armored aluminum conductor lt xlpe insulated cable of sizes 3.5 cx70 / 3.5 cx120 / 3.5 cx240 sq mm.to be laid under ground in hdpe pipes 184 digging of trenchbymaking pits after due survey with the help of utility detector of existing electrical / telephonic cable / and other utilites of public utilites departmentand laying of cables of size 3.5 cx70 / 3.5 cx120 / 3.5 cx240 sq mm. xlpe by manual drill ( by making moles ) 185 digging of trenchbymaking pits after due survey with the help of utility detector of existing electrical / telephonic cable / and other utilites of public utilites departmentand laying of cables of size 3.5 cx70 / 3.5 cx120 / 3.5 cx240 sq mm. xlpe through hdd method with the help of hdd machine 186 digging of trench by open trench method after due survey with the help of utility dectector of existing / telephonic cable and other utilites of public utilites departmentand laying of cables of size 3.5 cx70 / 3.5 cx120 / 3.5 cx240 sq mm. xlpe 187 back filling and restoring the road to make as original including supply of all material and row permission required from the land owner authority ( nagar nigam, pwd, nhai etc ) for all l.t. cables, pipe and service cables concerned with a single d.t. 188 laying of hdpe pipe of various sizes by horizontal drilling for under ground piping ( trenchless ) for above cable at road crossing min. depth of pipe shall be 1.5 mtr. below surface 110 mm. dia. 189 laying of gi pipe of 50mm dia ( external area ) 190 laying of gi pipe of 40mm dia ( external area ) 191 laying of pvc pipe heavy gauge 40 mm dia ( under ground area ) 192 erection of g.i. strip / m.s. strip of size 25x3 / 50x6 sqmm connecting type a / b / c pannel with spike rod / chemical earthing / deep bore earthing arrangement including required bolting / welding 193 dismantling of existing lt overhead line including stp poles, bare conductor / a.b. cable, pole accessories and transportation of dismantled materials to kesco store. 194 laying of aluminum armored xlpes cables size 2x6 sq mm. upto consumer meter 195 laying of aluminum armored xlpes cables size 2x10 sq mm. upto consumer meter 196 laying of aluminum armored xlpes cables size 4x16 sq mm. upto consumer meter 197 laying of aluminum armored xlpes cables size 4x25sq mm. upto consumer meter 198 installation, testing & commissioning of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubical should be weather proof, dust proof, bremen proof and in closer protection shall be ip 65 as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 2 mm crca sheet steel & provided with 2 mmhinged door including suitable foundation, main lt panel at substation 1000 & 630 kva ( type a 1 ) incomer 1 no. 1250 amp. acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ( outgoing 4 sets of 400 amp. tp mccb with spreader & extended handle ) ( 2 sets of 250amp. tp mccb with spreader & extended handle ) ( 2 sets of 100 0amp. tp mccb with spreader & extended handle ) 199 installation, testing & commissioning of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubicle should be weather proof, dust proof, bremen proof and in closer protection shall be ip 65 as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 2mmcrca sheet steel & provided with 2 mm hinged door including suitable foundation, main lt panel at substation 400 kva ( type a 2 ) ( incomer 1 set of 800 amp.acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ( outgoing 6 sets of 250 amp. tp mccb with spreader & extended handle ( 5no.+1no. capacitor panel ) ) ( 2 sets of 100 amp. tp mccb with spreader & extended handle ) 200 installation, testing & commissioning of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubical should be weather proof, dust proof, bremen proof and in closer protection shall be ip 65 as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 2mm sheet steel & provided with2mmhinged door including suitable foundation, main lt panel at substation 250 kva ( type a 3 ) ( incomer 1 set of 630 amp. acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ) ( outgoing 5 sets of 250 amp. tp mccb with spreader & extended handle ( 4no.+1no. capacitor panel ) ) ( 2 sets of 100 amp. tp mccb with spreader & extended handle ) 201 installation, testing & commissioning of outdoor type lt distribution box with a rupturing capacity of 50 ka at 415 volt called for individual items ( cpri approved manufacturer ) openable in front & back suitable for 3 phase, four wire, 50 hz ac supply & an ambient temperature of 45 deg. c. the cubical should be weather proof, dust proof, bremen proof and in closer protection shall be ip 65 as per is 2147 1962 and is 8623 the panels & switches boards shall be fabricated out of 2 mm crca sheet steel & provided with 2 mm hinged door including suitable foundation, main lt panel at substation 160 kva ( type a 4 ) ( incomer 1 set of 400 amp. acb with inbuilt mpr released with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) with control mcbs ) ( outgoing 4 sets of 250 amp. tp mccb with spreader & extended handle ( 3no.+1no. capacitor panel ) ) ( 2 sets of 100 amp. tp mccb with spreader & extended handle ) 202 installation, testing & commissioning of outdoor type feeder pillar panel to be made of 2mm. crca sheet & covers will be 2 mm crca sheet duly powder coated paint including suitable foundation with 400 amp. aluminum bus bar ( type b 1 ) with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) having : 1 no incomer 250amp. tp mccb and 6 no.out going 100 amp. tp mccb with spreader & extended handle. 203 installation, testing & commissioning of outdoor type feeder pillar panel to be made of 2mm. crca sheet & covers will be 2 mm crca sheet duly powder coated paint including suitable foundation with 300 amp. aluminum bus bar ( type b 2 ) with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) having :1 no incomer 250amp. tp mccb and 5 no.out going 100 amp. tp mccb spreader & extended handle. 204 installation, testing & commissioning of outdoor type feeder pillar panel to be made of 2mm. crca sheet & covers will be 2 mm crca sheet duly powder coated paint including suitable foundation with 300 amp. aluminum bus bar ( type b 3 ) with ( on / off indicating light ) ( metering on incomer 1 set of digital ammeter with ass ) ( 1 set of digital voltmeter with vss ) ( 1 set of led type phase indication light ( 22.5 mm ) having :1 no incomer 250 amp. tp mccb and 4 no.out going 100amp. tp mccb spreader & extended handle. 205 installation, testing & commissioning of lockable distribution box along with bar lock of size 450x450 mm including suitable foundation with bus bar 140 amp. tpn to feed up to 10 houses ( type c ) .panel to be made of 2mm. crca sheet 206 installation of2x10 sq mm. xlpe cable ( for street light ) 207 installation and laying of gi pipe of 40 mm dia under ground ( for street light ) 208 installation of junction box on stp / pcc pole with 900 mm long gi pipe 25 mm dia with clamp ( for street light connection ) 209 boring upto 39 feet and erection of gi pipe 40mm dia b class 40 feet long for connection with type a and b panel along with supply of g.i. strip of size 50x6 sqmm 210 erection / pegging of m.s.earth spike rod 2540x20 mm 211 erection of g.i. pipe chemical earthing electrode 3 mtr long 80 mm inner dia along with chemical powder 212 preparation and submission of 2 sets of detailed printed drawing / auto cad drawing / pdf ( along with digital copy ) of l.t. network of each d.t. depicting location of l.t. cables and all panels ( type a, b and c ) and separate list for all connections on type c panels in excel format 213 erection of single phase poly carbonate meter box after removal of existing meter box and connections of meters with armoured cable laid along with resealing of meter with seals provided by kesco 214 erection of three phase poly carbonate meter box after removal of existing meter box and connections of meters with armoured cable laid along with resealing of meter with seals provided by kesco 215 reconductoring of 11 kv oh line. 216 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 217 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 218 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in soft rock / soft rock / mettalic road / rcc / khranjaas per scope of work, approved drawings and specifications: 219 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 220 erection of following types of poles for 11 kv overhead line by providing and installing danger plate, anti climbing devices ( barbed wire ) , earthing material ( coil and 8swg gi wire ) , red oxide & aluminium paint, pole numbering excluding cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) or / and 200 mm average size bolders mixed with excavated earth etc as per scope of work, approved drawings and specifications: 221 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) cement concreting 0.65 cmt 222 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 223 normal soil 224 soft rock soil / soft rock / mettalic road / rcc / khranja 225 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 2 nos. ) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6 ) as per technical specifications, approved drawings and scope of works. 226 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 227 11 kv pin insulator with gi pin 228 11 kv 70kn disc insulator with strain hardware 229 dismantling of existing overhead line conductor & fittings and depositing to kesco store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 230 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit condcutor 231 erection, testing & commissioning of pre fabricated steel items like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washers all galvanized including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work. 232 earthing arrangement as per technical specificatons, approved drawings and scope of work. 233 excavation, erection, testing & commissioning of spike earthing of 2540 mm long with 20mm solid rod 234 excavation, erection, testing & commissioning of earthing coil 235 erection of 8 swg gi wire for earthing and guarding by providing gi nut, bolts & washers, turn buckle etc 236 strengthening of existing damaged pole by providing and welding 1.2mtr long 3 no ms angle 65*65*6mm and carrying out required grouting and pole plinth activities as per approved drawing and technical specification. 237 reconductoring of 11 kv ug line. 238 survey, route alignment & pole spotting and detection of existing electrical / telephonic cable / and other utilites of public utilites departments with the help of utilitiy dectector andpreparation of survey report and uploading in the web portal after approval of project manager. 239 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 240 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 241 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in soft rock / soft rock / mettalic road / rcc / khranjaas per scope of work, approved drawings and specifications: 242 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) 243 erection of following types of poles for 11 kv overhead line by providing and installing danger plate, anti climbing devices ( barbed wire ) , earthing material ( coil and 8swg gi wire ) , red oxide & aluminium paint, pole numbering excluding cement concrete foundation or refilling by bolders using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) or / and 200 mm average size bolders mixed with excavated earth etc as per scope of work, approved drawings and specifications: 244 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) and bottom galvanized as peris 2629 ( 1985 ) cement concreting 0.65 cmt 245 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 246 normal soil 247 soft rock soil / soft rock / metallic road / rcc / kharanja 248 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 2 nos. ) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips ( 1:3:6 ) as per technical specifications, approved drawings and scope of works. 249 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 250 11 kv pin insulator with gi pin 251 11 kv disc insulator 70 kn with strain hardware 252 erection, testing & commissioning of pre fabricated steel items like v cross arm, top clamp, dc cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washers duly galvanizedincluding painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work. 253 earthing arrangement as per technical specificatons, approved drawings and scope of work. 254 excavation, erection, testing & commissioning of spike earthing 2540 mm long with 20mm solid gi rod 255 excavation, erection, testing & commissioning of earthing coil 256 erection of 8 swg gi wire for earthing and guarding by providing gi nut, bolts & washers, turn buckle etc 257 laying of 11kv cable through hdd method including digging of pit 258 digging of trench .6 mtr wide .9 mtr to 1.5 mtr deep for laying of pipe and cable 259 normal soil 260 soft rock / kharanja 261 hard rock / metallic road / rcc 262 laying of gi pipe 6 dia in above digged trench and also for raising cable on double pole / structure laying of 11 kv cable 3x185 sqmm 263 laying of 11 kv cable through above pipe 264 laying of cable in above digged trench and also mounting upto line by using bricks / sand &stone pad as per rec norms 265 making andmounting of heat shrinkable jointing kit for 11 kv 3x185 sqmm xlpe cable 266 digging suitable pit and making straight through joint 11 kv 3x185 sqmm 267 making of straight through joint andconstruction of rb pit 3x1x1 mtr. with 9 inch thick side wall and 6 inch thick rcc bed along with rcc trench cover in three parts duly plastered and finsihed for housing st. through joint. box and filled with sand. 268 road restoration charges 269 normal soil 270 soft rock / kharanja 271 hard rock / metallic road / rcc 272 installationof 11 kvcapacitor bank including mounting steel galvanised structure and accessories as required as per detailed technical specifications, drawing and scope of works in following arrangements: 273 capacitor bank 1200 kvar auto type substation mounted with all associated equipment like 11 kv vcb along with adapter panel / complete mechanism for connection with existing busbar, c&r panel, cts, 11 kv 200a isolators with earth switch, rvt, 11 kv station class la, red oxide / aluminium painting, 2.5 sq.mm. pvc armoured stranded copper control cables, protection circuit and equipment, earthing, 16 mm dia ms nuts & bolts etc as required as per approved technical specifications, drawing and scope of works 274 capacitor bank 1500 kvar auto type substation mounted with all associated equipment like 11 kv vcb along with adapter panel / complete mechanism for connection with existing busbar, , c&r panel, cts, 11 kv 200a isolators with earth switch, rvt, 11 kv station class la, red oxide / aluminium painting, 2.5 sq.mm. pvc armoured stranded copper control cables, protection circuit and equipment, earthing, 16 mm dia ms nuts & bolts etc as required as per approved technical specifications, drawing and scope of works 275 erection of 11 kv xlpe insulated 3x185 sqmm armoured 276 erection of heat shrinkable jointing kit for 11 kv 3x185 sqmm xlpe cable 277 heat shrinkable jointing kit for 11 kv 3x185 xlpe cable indoor / outdoor termination kit 278 layingof11 kv acs dog covered conductor with all accessories....

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

32208463 development of distribution infrastructure of package mirzapur at mirzapur, sonbhadra and sant ravidas nagar district of puvvnluttar pradeshunderrevamped reforms based and results linked, distribution sector scheme 1 supply of consumer service cable 2 supply of armored service cable for consumer service connection with accessories as per technical specifications, scope of works and approved drawings 3 supply of single phase armored al cable size 2cx 6 sq mm 4 supply of three phase armored al cable size 4cx 16 sq mm 5 supply of 10 swg gi wire 6 supply of 8 swg gi wire 7 conversion of existing lt lines on bare conductor to areal bunch xlpe cable 8 conversion of existing lt lines with bare conductor to ab xlpe cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 9 supply of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 10 galvanized stay set for lt line with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, stay guy insulator, nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 11 conversion of existing lt lines using new earthing as per approved drawings, technical specifications and scope of work 12 supply of spike earthing made of 20mm x 2500 mm gi solid rod 13 supply of 8 swg gi wire for earthing and guarding 14 supply of following lt ab xlpe cable for conversion of existing lt bare conductor line with ab xlpe cable as required as per technical specification, approved drawings and scope of work: 15 supply of aerial bunchedxlpe cable 3 x 50 sqmm+1x35 sqmm. ( bare messenger wire ) +1x16 sqmm. 16 supply of aerial bunchedxlpe cable 3 x 70 sqmm.+1x50 sqmm. ( bare messenger wire ) +1x16 sqmm. 17 supply of aerial bunchedxlpe cable 3 x 95 sqmm.+1x70 sqmm. ( bare messenger wire ) + 1x16 sqmm. 18 supply of aerial bunchedxlpe cable 3 x 120 sqmm. + 1x95 sqmm. ( bare messenger wire ) +1x16 sqmm. 19 supply of pole mounted lt distribution box as per approved drawings, technical specifications and scope of work 20 supply of three phase smc distribution box with clamps 21 supply of single phase smc distribution box with clamps 22 supply of xlpe insulated al. cable for energisation of distribution box / kiosk as per approved drawings, technical specifications and scope of work 23 supply of 1x25 mm2 xlpe insulated al.cable 24 supply of stone pad ( 300x300x75 ) 25 supply of accessories for ab xlpe cable as per approved drawings, technical specifications and scope of work 26 stainless steel strap 27 hdg lt pole clamp with nut & bolt for laying abc 28 dead end clamp with i hook ( insulated ) 29 suspension clamp with i hook ( insulated ) 30 95 / 35 sqmm 70 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 31 120 / 50 sqmm 95 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 32 lt insulation piercing connector 120 50 sqmm 50 25 sqmm size ( for energizing distribution box ) 33 lt insulation piercing connector 120 50 sqmm 120 50 sqmm size ( for line to line jumpering ) 34 lt insulation piercing connector 16 25sqmmsize suitable for street light connection 35 pre insulated compression connectors size 16 sqmm suitable for ab xlpe cable 36 pre insulated compression connectors size 50 sqmm suitable for ab xlpe cable 37 pre insulated compression connectors size 70 sqmm suitable for ab xlpe cable 38 pre insulated compression connectors size 95 sqmm suitable for ab xlpe cable 39 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 40 heat shrinkable type end cap for ab xlpe cable 41 supply of new 11 kv lines : feeder segregation ( agriculture feeder ) 42 supply of support for 11 kv overhead line as per technical specification, approved drawings and scope of work 43 supply of 8.5m / 180 kgs pcc poles ( pcc pole as per state practice ) 44 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 45 supply for 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms transformer base channel, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 46 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work. 47 supply of pole accessories as per technical specification, approved drawing and scope of work 48 supply of 11 kv danger board 49 supply of stone pad 300x300x75 50 supply of barbed gi wire 12 swg 51 supply of stay set ( galvanized ) with 50x8 mm stay clamp, stay insulator ( 1 nos. ) , anchor plate ( 200x200x6 ) , nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 52 supply of insulator and hardware as per technical specification, approved drawings and scope of work. 53 supply of 11 kv45 kn polymer disc insulator along with suitable hardware fittings 54 supply of 11 kv 5 kn polymer pin insulators 55 supply of earthing arrangement as per technical specifications, approved drawings and scope of work. 56 supply of spike earthing 20mm x 2500 mm solid rod 57 chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diametergi pipe, gi strip of 24x3mm minimum in hard rock locations only. 58 supply of 8 swg gi wire for earthing and guarding 59 supply of 6 swg gi wire for earthing and guarding 60 supply of acsr conductors of following sizes with jointing sleeves, binding materials, pg clamps, bi metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work 61 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 62 supply of 11 kv, 600a, 3 ph, 3 pin type, vertical mounting type, gang operated, ab switch along with support insulators, base channel down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 63 supply of 11 kv lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 64 supply for 11 kv lineunder ground railway crossing with 2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) using 150mm dia gi pipes ( grade a for underground laying and grade b for pole support ) , outdoor heat shrinkable cable jointing kit, 11 kv lightening arrestor station class 10ka ( 6 nos. ) , lugs, 4 nos gi 3 meters long pipe earthing, 6 swg gi wires, cable markers, bi metallick clamps and jumpering etc as required as per technical specifications, drawings and scope of the work. 65 supply of 11 lv line underground highway crossing ensuring statutory clearancesas required as per technical specification, approved drawings and scope of work 66 supply of 11 kv lineforunder ground highway crossing by 2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) using 160 mm hdpe pipe at road crossing and 150mm dia gi pipes ( gradeb for pole support ) , outdoor heat shrinkable cable jointing kits, 11 kv lightening arrestor station class 10ka ( 6 nos. ) , lugs, 4 nos gi 3 meters long pipe earthing, 6 swg gi wires, cable markers, bi metallick clamps and jumpering etc as required as per technical specifications, drawings and scope of the work. 67 supply of 12 kv 3ph indoor type switch gear and 11 kv xlpe cable as per technical specifications, approved drawings and scope of works: 68 supply of indoor type 12 kv 3 ph 1250 a vcb with control and protection system for out going feeder consisting ofct, a meter, volt meter, relays, energy meter ( tvm ) dlms compliant & accessories complete as per specifications for feeder breaker protection 69 11 kv 3x 185 sqmm xlpe armored power cable, aluminum stranded conductor, including their termination materials like indoor and outdoor termination kit, glands, lugs, tagging, cable path marker etc as required as per technical specifications, approved drawings and scope of the works. 70 supply for augmentation of lines 71 supply for augmentation of 33 kv line 72 supply for augmentation of 3 phase 33 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 73 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 74 supply new pre fabricated hot dip galvanized steel item, for augmentation of 33 kv line, like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 75 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle etc. as per technical specification, approved drawings and scope of work. 76 supply of pole accessories as per technical specification, approved drawing and scope of work 77 supply of 33 kv danger board 78 supply of gi barbed wire 12 swg 79 supply for augmentation of 3 phase 33 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material, aluminum tape and helical preformed fittings etc as required as per technical specification, approved drawings and scope of work. 80 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 81 supply of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 82 supply of 33 kv under ground cable as per technical specification, approved drawings and scope of work. 83 supply of 3cx300 sqmm 33 kv xlpe armored cable 84 supply of accessories for 33 kv3cx300 sqmm xlpe armored cable ( 2 nos including one spare ) , like 160mm dia hdpe pipes for road crossing and 150 mm dia gi pipegrade b for pole support outdoor heat shrinkable cable jointing kits, lugs, cablepath markers, bi metallic clamps and 7 / 20 gi wire as per technical specification, approved drawing and scope of work 85 supplyof new insulator and hardware for augmentation of33 kv line as per technical specification, approved drawings and scope of work 86 supply of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 87 supply of 33 kv 10 kn polymer pin insulators 88 supply of new earthing arrangement for augmentation of33 kv line as per technical specifications, approved drawings and scope of work. 89 8 swg gi coil 115 turns ( 1.85 kg ) 90 chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diametergi pipe, gi strip of 24x3mm minimum in hard rock locations only. 91 supply of new stay set ( galvanized ) for 33 kv line with 50x8 mm stay clamp, guy insulator, anchor plate ( 300x300x8mm ) , nut bolts, turn buckles, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 92 supply of new gi wire for earthing and guarding for augmentation of33 kv line as per technical specification, approved drawings and scope of work. 93 supply of 6 swg gi wire 94 supply of 8 swg gi wire 95 supply of conductor accessories as per technical specification, approved drawing and scope of work 96 supply of pg clamp for dog to dog conductor 97 supply of pg clamp for panther to panther conductor 98 supply for augmentation of 11 kv lines 99 supply for augmentation of 3 phase 11 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 100 supply of 8.5 meter long / 180 kg pcc poles ( pcc pole as per state practice ) 101 supply for augmentation of 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 102 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work. 103 supply of pole accessories as per technical specification, approved drawing and scope of work 104 supply of 11 kv danger board 105 stone pad ( 300x300x75mm ) 106 supply of gi barbed wire 12 swg 107 supply for augmentation of 3 phase 11 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. 108 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 109 supply of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 110 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 111 supply for augmentation of 3 phase 11 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 112 supply of 11 kv 45 kn polymer disc insulator along with suitable hardware fittings 113 supply of 11 kv 5 kn polymer pin insulators 114 supply for augmentation of 3 phase 11 kv line using new earthing arrangement as per technical specifications, approved drawings and scope of work. 115 chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diametergi pipe, gi strip of 24x3mm minimum in hard rock locations only. 116 supply of gi earthing spike made of 20x2500mm solid rod 117 supply for augmentation of 3 phase 11 kv line using new stay set ( galvanized ) with 50x8 mm stay clamp, guy insulator, anchor plate ( 200x200x6mm ) , nut bolts, 1 no turn buckles, 1.8 m long 16 mm diameter solid gi stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 118 supply for augmentation of 3 phase 11 kv line using new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 119 supply of 6 swg gi wire 120 supply of 8 swg gi wire 121 supply of conductor accessories as per technical specification, approved drawing and scope of work 122 supply of pg clamp for weasel to weasel conductor 123 supply of pg clamp for dog to dog conductor 124 supply of pg clamp for rabbit to rabbit conductor 125 installation of dt capacitor 126 supply of dt capacitor with fitting as per technical specification, approved drawing and scope of work 127 supply of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 128 supply of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 129 supply of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 130 supply of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 131 supply of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 132 supply of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 133 erection part 134 installation of consumer service cable 135 installation of armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings 136 installation of single phase armored al cable size 2cx 6 sq mm 137 installation of three phase armored al cable size 4cx 16 sq mm 138 gi wire 8 swg 139 gi wire 10 swg 140 erection for conversion of existing lt lines on bare conductor to aerial bunch xlpe cable 141 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil of following pole as per scope of work, approved drawings and specifications: 142 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 143 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in soft rock where blasting is not required as per scope of work, approved drawings and specifications: 144 erection of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 145 erection of following types of poles for lt overhead line with stone pad, danger plate, anti climbing devices ( barbed wire ) , pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 146 erection of 8.5 m / 180 kgs pcc poles with base stone pad as required ( state practices of pcc pole and stone pad to be used ) 147 excavation of lt stay pit in following type of soils, as per scope of work, approved drawings and specifications: 148 normal soil 149 erection of soft rock soil where blasting is not required 150 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 151 removal of existing lt bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched xlpe cable, fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, pre insulated compression connectors, 16 mm dia ms nuts & bolts, pole clamps, stainless steel strap, single and three phase pole mounted distribution board, energisation of distribution box through 1x25 sqmm xlpe cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: 152 erection of aerial bunched xlpe cable3 x 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm 153 erection of aerial bunched xlpe cable 3 x 70 sqmm +1x50 sqmm ( bare messenger cum neutral ) +1x16 sqmm 154 erection of aerial bunched xlpe cable 3 x 95 sqmm +1x70 sqmm ( bare messenger cum neutral ) + 1x16 sqmm 155 erection of aerial bunched xlpe cable 3 x 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm 156 erection, testing & commissioning of earthing by inserting gi earthing spike made of 20mm solid rod as per approved drawings, scope of work and technical specifications 157 erection of 8 swg gi wire for earthing by providing gi nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications 158 erection, testing and commissioning of new 11 kv lines: feeder segregation ( agriculture feeder ) 159 survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of project manager 160 excavation of pole pit ( of depth 1 / 6th of pole length ) in normal soil for following type pole as per scope of work, approved drawings and specifications: 161 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 162 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.65 cmt 163 excavation of pole pit ( of depth 1 / 6th of pole length ) in soft rock for following type pole where blasting is not required as per scope of work, approved drawings and specifications: 164 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 165 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.65 cmt 166 excavation of pole pit ( of depth 1 / 6th of pole length ) in hard rock for following type pole where blasting is required as per scope of work, approved drawings and specifications: 167 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 168 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.65 cmt 169 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , red oxide & aluminum painting to stp poles including paint, numberingof poleby paint including cement concrete foundation using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 170 erection of 8.5 m / 180 kgs pcc poles with base pad including cement concreting, ( state practices of pcc pole, stone to be used ) 171 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) cement concreting 0.65 cmt 172 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washersas per technical specification, approved drawings and scope of work. 173 earthing arrangement as per technical specifications, approved drawings and scope of work. 174 erection, testing & commissioning of spike earthing 20mm x 2500mm solid rod 175 excavation, erection, testing & commissioning of chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diametergi pipe, gi strip of 24x3mm minimum in hard rock locations only. 176 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 177 normal soil 178 erection of soft rock soil where blasting is not required 179 erection of hard rock soil where blasting is required 180 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 1 nos. ) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 181 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 182 erection of 5 kn 11 kv polymer pin insulator 183 erection of 45 kn 11 kv polymer disc insulator with strain hardware 184 laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 185 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 186 erection, testing and commissioning of vertical type 11 kvab switch along with support insulators, base channel, down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 187 erection, testing & commissioning of 11 kv line for under ground railway crossing by2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) , using 150mm dia gi pipes, outdoor heat shrinkable cable jointing kits, lugs, 4 nosgi 3 meters long earthing pipe, 6 swg gi wires, cable markers, clamps, jumpering and 11 kv station type lightening arrestors ( 6 nos. ) , etc as required as per technical specifications, approved drawings and scope of he work. 188 erection, testing & commissioning of 11 kv line for under ground highway crossing by2 nos ( including one spare ) 3cx185 sqmm xlpe armored cable ( 0.3 km each ) , using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, 4 nosgi 3 meters long earthing pipe, 6 swg gi wires, cable markers, clamps, jumpering, 11 kv station type lightening arrestors ( 6 nos. ) , etc as required as per technical specifications, approved drawings and scope of he work. 189 erection of 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor typevacuum circuit breaker with adopter panel for out going feeder by leveling, alignment and welding on existing cable trench in control room. testing & commissioning of indoor vcb panel including 3 nos indoor type current transformer, a meter, volt meter, relay & accessories protection as per approved drawings, technical specifications and scope of the work.: 190 laying, erection, termination using indoor & outdoor termination kit, 11kv 3x 185 sqmm xlpearmored power cablesas per technical specifications, approved drawings and scope of works. : 191 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 192 erection of 6 swg gi wire 193 erection of 8 swg gi wire 194 extension of control room of 33 / 11 kv substation to accommodate vcb for new 11 kv feeders as per technical specification, approved drawing and scope of work. 195 design, engineering construction of control room building extension 300 sq feet including cost ofall materials, t&p and labour, etc. as per technical specification and approved drawing as per direction of employer 196 shifting of following distribution transformer along with fixture including dismantling , shifting and erection from one location to another location as per approved survey. 197 single phase transformer 198 three phase transformer 199 erection for augmentation of lines 200 erection for augmentation of 33 kv line 201 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 202 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 203 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in soft rock where blasting is not required as per scope of work, approved drawings and specifications: 204 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 205 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in hard rock where blasting is required as per scope of work, approved drawings and specifications: 206 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 207 erection of following types of additional poles matching with existing line supports by providing and installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminum including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 208 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 209 excavation of stay pit for 33 kv stay in following type of soils, as per scope of work, approved drawings and specifications: 210 normal soil 211 soft rock soil where blasting is not required 212 hard rock soil where blasting is required 213 erection of complete stay set with gi stay wire ( 7x4.00 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 214 erection, testing and commissioning of 33 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 215 erection of 33 kv 10 kn pin insulator with gi pin 216 erection of 33 kv 70 kn disc insulator with strain hardware ( set of 3, 11 kv disc insulators ) 217 erection, testing & commissioning of new pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. 218 dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store and laying out & stringing of new acsr conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. 219 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 220 stringing of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 221 erection, testing & commissioning of 33 kvunder ground cable by2 nos ( including one spare ) 3cx300 sqmm xlpe armored cable, using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering 7 / 20 gi wire etc as required as per technical specifications, approved drawings and scope of he work. 222 erection for augmentation of 3 phase 33 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 223 erection of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 224 erection of 33 kv 10 kn polymer pin insulators 225 erection, testing & commissioning of earthing as per technical specifications, approved drawings and scope of work. 226 8 swg gi coil 115 turns ( 1.85 kg ) 227 excavation, erection, testing & commissioning of chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diametergi pipe, gi strip of 24x3 mm minimum in hard rock locations only. 228 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 229 erection of 6 swg gi wire 230 erection of 8 swg gi wire 231 erection for augmentation of 11 kv lines 232 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 233 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 234 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in soft rock where blasting is not required as per scope of work, approved drawings and specifications: 235 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 236 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in hard rock where blasting is required as per scope of work, approved drawings and specifications: 237 erection of 8.5m / 180 kgs pcc poles ( pcc pole as per state practice ) 238 erection of following types of poles for 11 kv overhead line by providing and installing danger plate, anti climbing devices ( barbed wire ) , pole numbering by paint including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 239 erection of 8.5 m / 180 kgs pcc poles withbase stone pad ( state practices of pcc pole and base plate / stone to be used ) 240 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 241 normal soil 242 soft rock soil where blasting is not required 243 hard rock soil where blasting is required 244 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 245 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 246 erection of 11 kv pin insulator with gi pin 247 erection of 11 kv disc insulator with strain hardware 248 dismantling of existing overhead line conductor & fittings and depositing to employers store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 249 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 250 stringing of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 251 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 252 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and hdg ms nuts, bolts & washers as per technical specification, approved drawings and scope of work. 253 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 254 erection of 5 kn 11 kv polymer pin insulator 255 erection of 45 kn 11 kv polymer disc insulator with strain hardware 256 earthingand guarding arrangement as per technical specifications, approved drawings and scope of work. 257 erection, testing & commissioning of spike earthing 20mm solid rod 258 excavation, erection, testing & commissioning of chemicalrod earthing including electrode, chemical, with 2000mm long, 50 mm diametergi pipe, gi strip of 24x3mm minimum in hard rock locations only. 259 erection of 8 swg gi wire for earthing and guarding 260 erection of 6 swg gi wire for earthing and guarding 261 erection of dt capacitor 262 erection, testing & commissioning offollowing 440 volt lt shunt capacitor including mounting structure and accessories as required as per technical specifications, approved drawings and scope of work. 263 erection of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 264 erection of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 265 erection of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 266 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 267 erection of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 268 erection of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 269 words...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

32208152 development of distribution infrastructure of packageazamgarh at azamgarh, mau and ballia district of puvvnluttar pradesh under revamped reforms based and results linked, distribution sector scheme 1 supply of consumer service cable 2 supply of armored service cable for consumer service connection with accessories as per technical specifications, scope of works and approved drawings 3 supply of single phase armored al cable size 2cx 6 sq mm 4 supply of three phase armored al cable size 4cx 16 sq mm 5 supply of 10 swg gi wire 6 supply of 8 swg gi wire 7 conversion of existing lt lines on bare conductor to areal bunch xlpe cable 8 conversion of existing lt lines with bare conductor to ab xlpe cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 9 supply of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 10 galvanized stay set for lt line with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, stay guy insulator, nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 11 conversion of existing lt lines using new earthing as per approved drawings, technical specifications and scope of work 12 supply of spike earthing made of 20mm x 2500 mm gi solid rod 13 supply of 8 swg gi wire for earthing and guarding 14 supply of following lt ab xlpe cable for conversion of existing lt bare conductor line with ab xlpe cable as required as per technical specification, approved drawings and scope of work: 15 supply of aerial bunchedxlpe cable 3 x 50 sqmm+1x35 sqmm. ( bare messenger wire ) +1x16 sqmm. 16 supply of aerial bunchedxlpe cable 3 x 70 sqmm.+1x50 sqmm. ( bare messenger wire ) +1x16 sqmm. 17 supply of aerial bunchedxlpe cable 3 x 95 sqmm.+1x70 sqmm. ( bare messenger wire ) + 1x16 sqmm. 18 supply of aerial bunchedxlpe cable 3 x 120 sqmm. + 1x95 sqmm. ( bare messenger wire ) +1x16 sqmm. 19 supply of pole mounted lt distribution box as per approved drawings, technical specifications and scope of work 20 supply of three phase smc distribution box with clamps 21 supply of single phase smc distribution box with clamps 22 supply of xlpe insulated al. cable for energisation of distribution box / kiosk as per approved drawings, technical specifications and scope of work 23 supply of 1x25 mm2 xlpe insulated al.cable 24 supply of stone pad ( 300x300x75 ) 25 supply of accessories for ab xlpe cable as per approved drawings, technical specifications and scope of work 26 stainless steel strap 27 hdg lt pole clamp with nut & bolt for laying abc 28 dead end clamp with i hook ( insulated ) 29 suspension clamp with i hook ( insulated ) 30 95 / 35 sqmm 70 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 31 120 / 50 sqmm 95 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 32 lt insulation piercing connector 120 50 sqmm 50 25 sqmm size ( for energizing distribution box ) 33 lt insulation piercing connector 120 50 sqmm 120 50 sqmm size ( for line to line jumpering ) 34 lt insulation piercing connector 16 25sqmmsize suitable for street light connection 35 pre insulated compression connectors size 16 sqmm suitable for ab xlpe cable 36 pre insulated compression connectors size 50 sqmm suitable for ab xlpe cable 37 pre insulated compression connectors size 70 sqmm suitable for ab xlpe cable 38 pre insulated compression connectors size 95 sqmm suitable for ab xlpe cable 39 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 40 heat shrinkable type end cap for ab xlpe cable 41 supply for augmentation of lines 42 supply for augmentation of 33 kv line 43 supply for augmentation of 3 phase 33 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 44 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 45 supply new pre fabricated hot dip galvanized steel item, for augmentation of 33 kv line, like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 46 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work. 47 supply of pole accessories as per technical specification, approved drawing and scope of work 48 supply of 33 kv danger board 49 supply of gi barbed wire 12 swg 50 supply for augmentation of 3 phase 33 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material, aluminum tape and helical preformed fittings etc as required as per technical specification, approved drawings and scope of work. 51 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 52 supply of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 53 supply of 33 kv under ground cable as per technical specification, approved drawings and scope of work. 54 supply of 3cx300 sqmm 33 kv xlpe armored cable 55 supply of 33 kv3cx300 sqmm xlpe armored cable ( 2 nos including one spare ) accessories like 160mm dia hdpe pipes for road crossing and 150 mm dia gi pipegrade b for pole support outdoor heat shrinkable cable jointing kits, lugs, cablepath markers, bi metallic clamps and 7 / 20 gi wire as per technical specification, approved drawing and scope of work 56 supplyof new insulator and hardware for augmentation of33 kv line as per technical specification, approved drawings and scope of work 57 supply of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 58 supply of 33 kv 10 kn polymer pin insulators 59 supply of new earthing arrangement for augmentation of33 kv line as per technical specifications, approved drawings and scope of work. 60 8 swg gi coil 115 turns ( 1.85 kg ) 61 supply of new stay set ( galvanized ) for 33 kv line with 50x8 mm stay clamp, guy insulator, anchor plate ( 300x300x8mm ) , nut bolts, turn buckles, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 62 supply of new gi wire for earthing and guarding for augmentation of33 kv line as per technical specification, approved drawings and scope of work. 63 supply of 6 swg gi wire 64 supply of 8 swg gi wire 65 supply of conductor accessories as per technical specification, approved drawing and scope of work 66 supply of pg clamp for dog to dog conductor 67 supply of pg clamp for panther to panther conductor 68 supply for augmentation of 11 kv lines 69 supply for augmentation of 3 phase 11 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 70 supply of 8.5 meter long / 180 kg pcc poles ( pcc pole as per state practice ) 71 supply for augmentation of 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 72 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work. 73 supply of pole accessories as per technical specification, approved drawing and scope of work 74 supply of 11 kv danger board 75 stone pad ( 300x300x75mm ) 76 supply of gi barbed wire 12 swg 77 supply for augmentation of 3 phase 11 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. 78 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 79 supply of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 80 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 81 supply for augmentation of 3 phase 11 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 82 supply of 11 kv 45 kn polymer disc insulator along with suitable hardware fittings 83 supply of 11 kv 5 kn polymer pin insulators 84 supply for augmentation of 3 phase 11 kv line using new earthing arrangement as per technical specifications, approved drawings and scope of work. 85 supply of gi earthing spike made of 20x2500mm solid rod 86 supply for augmentation of 3 phase 11 kv line using new stay set ( galvanized ) with 50x8 mm stay clamp, guy insulator, anchor plate ( 200x200x6mm ) , nut bolts, 1 no turn buckles, 1.8 m long 16 mm diameter solid gi stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 87 supply for augmentation of 3 phase 11 kv line using new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 88 supply of 6 swg gi wire 89 supply of 8 swg gi wire 90 supply of conductor accessories as per technical specification, approved drawing and scope of work 91 supply of pg clamp for weasel to weasel conductor 92 supply of pg clamp for dog to dog conductor 93 supply of pg clamp for rabbit to rabbit conductor 94 installation of dt capacitor 95 supply of dt capacitor with fitting as per technical specification, approved drawing and scope of work 96 supply of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 97 supply of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 98 supply of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 99 supply of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 100 supply of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 101 supply of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 102 erection part 103 installation of consumer service cable 104 installation of armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings 105 installation of single phase armored al cable size 2cx 6 sq mm 106 installation of three phase armored al cable size 4cx 16 sq mm 107 gi wire 8 swg 108 gi wire 10 swg 109 erection for conversion of existing lt lines on bare conductor to aerial bunch xlpe cable 110 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil of following pole as per scope of work, approved drawings and specifications: 111 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 112 erection of following types of poles for lt overhead line with stone pad, danger plate, anti climbing devices ( barbed wire ) , pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 113 erection of 8.5 m / 180 kgs pcc poles with base stone pad as required ( state practices of pcc pole and stone pad to be used ) 114 excavation of lt stay pit in following type of soils, as per scope of work, approved drawings and specifications: 115 normal soil 116 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 117 removal of existing lt bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched xlpe cable, fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, pre insulated compression connectors, 16 mm dia ms nuts & bolts, pole clamps, stainless steel strap, single and three phase pole mounted distribution board, energisation of distribution box through 1x25 sqmm xlpe cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: 118 erection of aerial bunched xlpe cable3 x 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm 119 erection of aerial bunched xlpe cable 3 x 70 sqmm +1x50 sqmm ( bare messenger cum neutral ) +1x16 sqmm 120 erection of aerial bunched xlpe cable 3 x 95 sqmm +1x70 sqmm ( bare messenger cum neutral ) + 1x16 sqmm 121 erection of aerial bunched xlpe cable 3 x 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm 122 erection, testing & commissioning of earthing by inserting gi earthing spike made of 20mm solid rod as per approved drawings, scope of work and technical specifications 123 erection of 8 swg gi wire for earthing as per approved drawings, scope of work and technical specifications 124 erection for augmentation of lines 125 erection for augmentation of 33 kv line 126 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 127 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 128 erection of following types of additional poles matching with existing line supports by installing danger plate, anti climbing devices ( barbed wire ) , red oxide & aluminum painting including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 129 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 130 excavation of stay pit for 33 kv stay in following type of soils, as per scope of work, approved drawings and specifications: 131 normal soil 132 erection of complete stay set with gi stay wire ( 7x4.00 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 133 erection, testing and commissioning of 33 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 134 erection of 33 kv 10 kn pin insulator with gi pin 135 erection of 33 kv 70 kn disc insulator with strain hardware ( set of 3, 11 kv disc insulators ) 136 erection, testing & commissioning of new pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. 137 dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store and laying out & stringing of new acsr conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. 138 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 139 stringing of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 140 erection, testing & commissioning of 33 kvunder ground cable by2 nos ( including one spare ) 3cx300 sqmm xlpe armored cable, using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering, etc as required as per technical specifications, approved drawings and scope of he work. 141 erection for augmentation of 3 phase 33 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 142 erection of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 143 erection of 33 kv 10 kn polymer pin insulators 144 erection, testing & commissioning of earthing as per technical specifications, approved drawings and scope of work. 145 8 swg gi coil 115 turns ( 1.85 kg ) 146 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 147 erection of 6 swg gi wire 148 erection of 8 swg gi wire 149 erection for augmentation of 11 kv lines 150 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 151 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 152 erection of following types of poles for 11 kv overhead line by providing and installing danger plate, anti climbing devices ( barbed wire ) , pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 153 erection of 8.5 m / 180 kgs pcc poles withbase stone pad ( state practices of pcc pole and base plate / stone to be used ) 154 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 155 normal soil 156 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 157 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 158 erection of 11 kv pin insulator with gi pin 159 erection of 11 kv disc insulator with strain hardware 160 dismantling of existing overhead line conductor & fittings and depositing to employers store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 161 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 162 stringing of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 163 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 164 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and hdg ms nuts, bolts & washers as per technical specification, approved drawings and scope of work. 165 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 166 erection of 5 kn 11 kv polymer pin insulator 167 erection of 45 kn 11 kv polymer disc insulator with strain hardware 168 earthingand guarding arrangement as per technical specifications, approved drawings and scope of work. 169 erection, testing & commissioning of spike earthing 20mm solid rod 170 erection of 8 swg gi wire for earthing and guarding 171 erection of 6 swg gi wire for earthing and guarding 172 erection of dt capacitor 173 erection, testing & commissioning offollowing 440 volt lt shunt capacitor including mounting structure and accessories as required as per technical specifications, approved drawings and scope of work. 174 erection of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 175 erection of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 176 erection of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 177 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 178 erection of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 179 erection of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 180 words...

Purvanchal Vidyut Vitaran Nigam Limited - Uttar Pradesh

32208114 development of distribution infrastructure of packagevaranasi 1 at varanasi district of puvvnluttar pradesh under revamped reforms based and results linked, distribution sector scheme 1 supply of consumer service cable 2 supply of armored service cable for consumer service connection with accessories as per technical specifications, scope of works and approved drawings 3 supply of single phase armored al cable size 2cx 6 sq mm 4 supply of three phase armored al cable size 4cx 16 sq mm 5 supply of 10 swg gi wire 6 supply of 8 swg gi wire 7 conversion of existing lt lines on bare conductor to areal bunch xlpe cable 8 conversion of existing lt lines with bare conductor to ab xlpe cable using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 9 supply of 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 10 galvanized stay set for lt line with anchor plate ( 200x200x6mm ) , 50x8mm stay clamp, stay guy insulator, nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi stranded wire etc as required as per technical specification, approved drawings and scope of work. 11 conversion of existing lt lines using new earthing as per approved drawings, technical specifications and scope of work 12 supply of spike earthing made of 20mm x 2500 mm gi solid rod 13 supply of 8 swg gi wire for earthing and guarding 14 supply of following lt ab xlpe cable for conversion of existing lt bare conductor line with ab xlpe cable as required as per technical specification, approved drawings and scope of work: 15 supply of aerial bunchedxlpe cable 3 x 50 sqmm+1x35 sqmm. ( bare messenger wire ) +1x16 sqmm. 16 supply of aerial bunchedxlpe cable 3 x 70 sqmm.+1x50 sqmm. ( bare messenger wire ) +1x16 sqmm. 17 supply of aerial bunchedxlpe cable 3 x 95 sqmm.+1x70 sqmm. ( bare messenger wire ) + 1x16 sqmm. 18 supply of aerial bunchedxlpe cable 3 x 120 sqmm. + 1x95 sqmm. ( bare messenger wire ) +1x16 sqmm. 19 supply of pole mounted lt distribution box as per approved drawings, technical specifications and scope of work 20 supply of three phase smc distribution box with clamps 21 supply of single phase smc distribution box with clamps 22 supply of xlpe insulated al. cable for energisation of distribution box / kiosk as per approved drawings, technical specifications and scope of work 23 supply of 1x25 mm2 xlpe insulated al.cable 24 supply of stone pad ( 300x300x75 ) 25 supply of accessories for ab xlpe cable as per approved drawings, technical specifications and scope of work 26 stainless steel strap 27 hdg lt pole clamp with nut & bolt for laying abc 28 dead end clamp with i hook ( insulated ) 29 suspension clamp with i hook ( insulated ) 30 95 / 35 sqmm 70 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 31 120 / 50 sqmm 95 / 25 sqmm pg clamps ( for line to line jumpering & energizing db neutral ) 32 lt insulation piercing connector 120 50 sqmm 50 25 sqmm size ( for energizing distribution box ) 33 lt insulation piercing connector 120 50 sqmm 120 50 sqmm size ( for line to line jumpering ) 34 lt insulation piercing connector 16 25sqmmsize suitable for street light connection 35 pre insulated compression connectors size 16 sqmm suitable for ab xlpe cable 36 pre insulated compression connectors size 50 sqmm suitable for ab xlpe cable 37 pre insulated compression connectors size 70 sqmm suitable for ab xlpe cable 38 pre insulated compression connectors size 95 sqmm suitable for ab xlpe cable 39 pre insulated compression connectors size 120 sqmm suitable for ab xlpe cable 40 heat shrinkable type end cap for ab xlpe cable 41 supply of new 11 kv lines : feeder segregation ( agriculture feeder ) 42 supply of support for 11 kv overhead line as per technical specification, approved drawings and scope of work 43 supply of 8.5m / 180 kgs pcc poles ( pcc pole as per state practice ) 44 supply for 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms transformer base channel, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 45 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 46 supply of pole accessories as per technical specification, approved drawing and scope of work 47 supply of 11 kv danger board 48 supply of stone pad 300x300x75 49 supply of barbed gi wire 12 swg 50 supply of stay set ( galvanized ) with 50x8 mm stay clamp, stay insulator ( 1 nos. ) , anchor plate ( 200x200x6 ) , nut bolts, 1 nos turn buckles, 1.8 m long, 16 mm diameter solid gs stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 51 supply of insulator and hardware as per technical specification, approved drawings and scope of work. 52 supply of 11 kv45 kn polymer disc insulator along with suitable hardware fittings 53 supply of 11 kv 5 kn polymer pin insulators 54 supply of earthing arrangement as per technical specifications, approved drawings and scope of work. 55 supply of spike earthing 20mm x 2500 mm solid rod 56 supply of 8 swg gi wire for earthing and guarding 57 supply of 6 swg gi wire for earthing and guarding 58 supply of acsr conductors of following sizes with jointing sleeves, binding materials, pg clamps, bi metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work 59 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 60 supply of 11 kv, 600a, 3 ph, 3 pin type, vertical mounting type, gang operated, ab switch along with support insulators, base channel down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 61 supply of 12 kv 3ph indoor type switch gear and 11 kv xlpe cable as per technical specifications, approved drawings and scope of works: 62 supply of indoor type 12 kv 3 ph 1250 a vcb with control and protection system for out going feeder consisting ofct, a meter, volt meter, relays, energy meter ( tvm ) dlms compliant & accessories complete as per specifications for feeder breaker protection 63 11 kv 3x 185 sqmm xlpe armored power cable, aluminum stranded conductor, including their termination materials like indoor and outdoor termination kit, glands, lugs, tagging, cable path marker etc as required as per technical specifications, approved drawings and scope of the works. 64 supply for augmentation of lines 65 supply for augmentation of 33 kv line 66 supply for augmentation of 3 phase 33 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 67 supply of 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 68 supply new pre fabricated hot dip galvanized steel item, for augmentation of 33 kv line, like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle ( 65x65x6mm ) , ms flats ( 65x8mm ) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 69 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc. as per technical specification, approved drawings and scope of work. 70 supply of pole accessories as per technical specification, approved drawing and scope of work 71 supply of 33 kv danger board 72 supply of gi barbed wire 12 swg 73 supply for augmentation of 3 phase 33 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material, aluminum tape and helical preformed fittings etc as required as per technical specification, approved drawings and scope of work. 74 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 75 supply of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 76 supply of 33 kv under ground cable as per technical specification, approved drawings and scope of work. 77 supply of 3cx300 sqmm 33 kv xlpe armored cable 78 supply of accessories for 33 kv3cx300 sqmm xlpe armored cable ( 2 nos including one spare ) , like 160mm dia hdpe pipes for road crossing and 150 mm dia gi pipegrade b for pole support outdoor heat shrinkable cable jointing kits, lugs, cablepath markers, bi metallic clamps, 7 / 20 gi wireas per technical specification, approved drawing and scope of work 79 supplyof new insulator and hardware for augmentation of33 kv line as per technical specification, approved drawings and scope of work 80 supply of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 81 supply of 33 kv 10 kn polymer pin insulators 82 supply of new earthing arrangement for augmentation of33 kv line as per technical specifications, approved drawings and scope of work. 83 8 swg gi coil 115 turns ( 1.85 kg ) 84 supply of new stay set ( galvanized ) for 33 kv line with 50x8 mm stay clamp, guy insulator, anchor plate ( 300x300x8mm ) , nut bolts, turn buckles, 1.8 m long, 20 mm diameter solid gs stay rod & 7 / 4.00 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 85 supply of new gi wire for earthing and guarding for augmentation of33 kv line as per technical specification, approved drawings and scope of work. 86 supply of 6 swg gi wire 87 supply of 8 swg gi wire 88 supply of conductor accessories as per technical specification, approved drawing and scope of work 89 supply of pg clamp for dog to dog conductor 90 supply of pg clamp for panther to panther conductor 91 supply for augmentation of 11 kv lines 92 supply for augmentation of 3 phase 11 kv line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 93 supply of 8.5 meter long / 180 kg pcc poles ( pcc pole as per state practice ) 94 supply for augmentation of 3 phase 11 kv line using new pre fabricated hot dip galvanized steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, ms angle, ms flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 95 supply of hot dip galvanized ms nuts, bolts with washers and turn buckle for guarding etc.as per technical specification, approved drawings and scope of work. 96 supply of pole accessories as per technical specification, approved drawing and scope of work 97 supply of 11 kv danger board 98 stone pad ( 300x300x75mm ) 99 supply of gi barbed wire 12 swg 100 supply for augmentation of 3 phase 11 kv line replacing existing conductor with following type of new acsr conductor including jointing sleeves, binding material and helicon formed fittings etc as required as per technical specification, approved drawings and scope of work. 101 supply of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 102 supply of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 103 supply of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 104 supply for augmentation of 3 phase 11 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 105 supply of 11 kv 45 kn polymer disc insulator along with suitable hardware fittings 106 supply of 11 kv 5 kn polymer pin insulators 107 supply for augmentation of 3 phase 11 kv line using new earthing arrangement as per technical specifications, approved drawings and scope of work. 108 supply of gi earthing spike made of 20x2500mm solid rod 109 supply for augmentation of 3 phase 11 kv line using new stay set ( galvanized ) with 50x8 mm stay clamp, guy insulator, anchor plate ( 200x200x6mm ) , nut bolts, 1 no turn buckles, 1.8 m long 16 mm diameter solid gi stay rod & 7 / 3.15 mm dia gi strandedwire complete as per technical specification, approved drawings and scope of work. 110 supply for augmentation of 3 phase 11 kv line using new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 111 supply of 6 swg gi wire 112 supply of 8 swg gi wire 113 supply of conductor accessories as per technical specification, approved drawing and scope of work 114 supply of pg clamp for weasel to weasel conductor 115 supply of pg clamp for dog to dog conductor 116 supply of pg clamp for rabbit to rabbit conductor 117 installation of dt capacitor 118 supply of dt capacitor with fitting as per technical specification, approved drawing and scope of work 119 supply of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 120 supply of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 121 supply of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 122 supply of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 123 supply of lt shunt capacitor 440 volt 63 kvar 3phase 50hz ip65 124 supply of lt shunt capacitor 440 volt 100 kvar 3phase 50hz ip65 125 erection part 126 installation of consumer service cable 127 installation of armored consumer service cable with accessories including dismantling of existing service cable as per technical specifications, scope of works and approved drawings 128 installation of single phase armored al cable size 2cx 6 sq mm 129 installation of three phase armored al cable size 4cx 16 sq mm 130 gi wire 8 swg 131 gi wire 10 swg 132 erection for conversion of existing lt lines on bare conductor to aerial bunch xlpe cable 133 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil of following pole as per scope of work, approved drawings and specifications: 134 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 135 erection of following types of poles for lt overhead line with stone pad, danger plate, anti climbing devices ( barbed wire ) , pole numbering by paint with cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 136 erection of 8.5 m / 180 kgs pcc poles with base stone pad as required ( state practices of pcc pole and stone pad to be used ) 137 excavation of lt stay pit in following type of soils, as per scope of work, approved drawings and specifications: 138 normal soil 139 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 140 removal of existing lt bare line conductor & fixtures, depositing to stores of employer and erection, testing & commissioning of new areal bunched xlpe cable, fixing tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type i & type ii, pre insulated compression connectors, 16 mm dia ms nuts & bolts, pole clamps, stainless steel strap, single and three phase pole mounted distribution board, energisation of distribution box through 1x25 sqmm xlpe cable fixing end cap etc. as required as per technical specification, approved drawings and scope of work: 141 erection of aerial bunched xlpe cable3 x 50 sqmm +1x35 sqmm ( bare messenger cum neutral ) +1x16 sqmm 142 erection of aerial bunched xlpe cable 3 x 70 sqmm +1x50 sqmm ( bare messenger cum neutral ) +1x16 sqmm 143 erection of aerial bunched xlpe cable 3 x 95 sqmm +1x70 sqmm ( bare messenger cum neutral ) + 1x16 sqmm 144 erection of aerial bunched xlpe cable 3 x 120 sqmm+ 1x95 sqmm ( bare messenger cum neutral ) +1x16 sqmm 145 erection, testing & commissioning of earthing by inserting gi earthing spike made of 20mm solid rod as per approved drawings, scope of work and technical specifications 146 erection of 8 swg gi wire for earthing by providing gi nut, bolts & washers, turn buckle etc as per approved drawings, scope of work and technical specifications 147 erection, testing and commissioning of new 11 kv lines: feeder segregation ( agriculture feeder ) 148 survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of project manager 149 excavation of pole pit ( of depth 1 / 6th of pole length ) in normal soil for following type pole as per scope of work, approved drawings and specifications: 150 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 151 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminumto stp poles inluding paint, numberingof poleby paint including cement concrete foundation using cement concreting foundation 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 152 erection of 8.5 m / 180 kgs pcc poles with base pad including cement concreting, ( state practices of pcc pole, stone to be used ) 153 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and ms nuts, bolts & washersas per technical specification, approved drawings and scope of work. 154 earthing arrangement as per technical specifications, approved drawings and scope of work. 155 erection, testing & commissioning of spike earthing 20mm x 2500mm solid rod 156 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 157 normal soil 158 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator ( 1 nos. ) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 159 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 160 erection of 5 kn 11 kv polymer pin insulator 161 erection of 45 kn 11 kv polymer disc insulator with strain hardware 162 laying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 163 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel 164 erection, testing and commissioning of vertical type 11 kvab switch along with support insulators, base channel, down pipe, arcing horns etc. complete asper technical specifications, scope of works and approved drawings 165 erection of 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor typevacuum circuit breaker with adopter panel for out going feeder by leveling, alignment and welding on existing cable trench in control room. testing & commissioning of indoor vcb panel including 3 nos indoor type current transformer, a meter, volt meter, relay & accessories protection as per approved drawings, technical specifications and scope of the work.: 166 laying, erection, termination using indoor & outdoor termination kit, 11kv 3x 185 sqmm xlpearmored power cablesas per technical specifications, approved drawings and scope of works. : 167 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 168 erection of 6 swg gi wire 169 erection of 8 swg gi wire 170 extension of control room of 33 / 11 kv substation to accommodate vcb for new 11 kv feeders as per technical specification, approved drawing and scope of work. 171 design, engineering construction of control room building extension 300 sq feet including cost ofall materials, t&p and labour, etc. as per technical specification and approved drawing as per direction of employer 172 shifting of following distribution transformer along with fixture including dismantling , shifting and erection from one location to another location as per approved survey. 173 single phase transformer 174 three phase transformer 175 erection for augmentation of lines 176 erection for augmentation of 33 kv line 177 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 178 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 179 erection of following types of additional poles matching with existing line supports by installing danger plate, anti climbing devices ( barbed wire ) , painting with red oxide & aluminum including paint, pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 180 11 m long steel tubular poles with welded steel base plate of designation 410 sp 55 ( is 2713, pt i, ii, iii 1980 ) 181 excavation of stay pit for 33 kv stay in following type of soils, as per scope of work, approved drawings and specifications: 182 normal soil 183 erection of complete stay set with gi stay wire ( 7x4.00 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 184 erection, testing and commissioning of 33 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 185 erection of 33 kv 10 kn pin insulator with gi pin 186 erection of 33 kv 70 kn disc insulator with strain hardware ( set of 3, 11 kv disc insulators ) 187 erection, testing & commissioning of new pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. 188 dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store and laying out & stringing of new acsr conductor of following sizes by providing jointing sleeves, binding wire & tape & helical formed fittings etc as required as per technical specification, approved drawings and scope of work. 189 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog replacing existing racoon conductor 190 stringing of 30 / 3.00 + 7 / 3.00 mm ( 200 mm² al. area ) panther replacing existing dog / racoon conductor 191 erection, testing & commissioning of 33 kvunder ground cable by2 nos ( including one spare ) 3cx300 sqmm xlpe armored cable, using 160 mm hdpe pipe at road crossing, 150mm dia gi pipes for cable support, outdoor heat shrinkable cable jointing kits, lugs, cable markers, clamps, jumpering and 7 / 20 gi wire etc as required as per technical specifications, approved drawings and scope of he work. 192 erection for augmentation of 3 phase 33 kv line using new insulator and hardware as per technical specification, approved drawings and scope of work 193 erection of 33 kv 70 kn polymer disc insulator along with suitable hardware fittings 194 erection of 33 kv 10 kn polymer pin insulators 195 erection, testing & commissioning of earthing as per technical specifications, approved drawings and scope of work. 196 8 swg gi coil 115 turns ( 1.85 kg ) 197 erection, testing & commissioning of new gi wire for earthing and guarding as per technical specification, approved drawings and scope of work. 198 erection of 6 swg gi wire 199 erection of 8 swg gi wire 200 erection for augmentation of 11 kv lines 201 excavation of additional pole pit ( of depth 1 / 6th of pole length ) in normal soil as per scope of work, approved drawings and specifications: 202 8.5 m / 180 kgs pcc poles ( pcc pole as per state practice ) 203 erection of following types of poles for 11 kv overhead line by installing danger plate, anti climbing devices ( barbed wire ) , pole numbering including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) etc as per scope of work, approved drawings and specifications: 204 erection of 8.5 m / 180 kgs pcc poles withbase stone pad ( state practices of pcc pole and base plate / stone to be used ) 205 excavation of stay pit in following type of soils, as per scope of work, approved drawings and specifications: 206 normal soil 207 erection of complete stay set with gi stay wire ( 7x3.15 mm dia ) , binding of stay wire, by providing guy stay insulator and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips ( 1:2:4 ) as per technical specifications, approved drawings and scope of works. 208 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 209 erection of 11 kv pin insulator with gi pin 210 erection of 11 kv disc insulator with strain hardware 211 dismantling of existing overhead line conductor & fittings and depositing to employers store, laying out, tensioning, binding of new conductor and tightening of stays and stringing, testing and commissioning of acsrconductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting pg clamps etc as required as per approved drawings, scope of work and technical specifications 212 stringing of 6 / 2.59 + 1 / 2.59 mm ( 30 mm² al. area ) weasel by replacing existing weasel / squirrel conductor 213 stringing of 6 / 3.35 + 1 / 3.35 mm ( 50 mm² al. area ) rabbit by replacing existing weasel / squirrel conductor 214 stringing of 6 / 4.72 mm+7 / 1.57 mm ( 100 mm² al. area ) dog by replacing existing racoon / rabbit conductor 215 erection, testing & commissioning of pre fabricated hdg steel items like v cross arm, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of ms channels, ms angle, ms flats of given sizes for over head structures and hdg ms nuts, bolts & washers as per technical specification, approved drawings and scope of work. 216 erection, testing and commissioning of 11 kv insulator including their hardware fittings as per technical specification, approved drawings and scope of work. 217 erection of 5 kn 11 kv polymer pin insulator 218 erection of 45 kn 11 kv polymer disc insulator with strain hardware 219 earthingand guarding arrangement as per technical specifications, approved drawings and scope of work. 220 erection, testing & commissioning of spike earthing 20mm solid rod 221 erection of 8 swg gi wire for earthing and guarding 222 erection of 6 swg gi wire for earthing and guarding 223 erection of dt capacitor 224 erection, testing & commissioning offollowing 440 volt lt shunt capacitor including mounting structure and accessories as required as per technical specifications, approved drawings and scope of work. 225 erection of lt shunt capacitor 440 volt 10 kvar 3phase 50hz ip65 226 erection of lt shunt capacitor 440 volt 16 kvar 3phase 50hz ip65 227 erection of lt shunt capacitor 440 volt 25 kvar 3phase 50hz ip65 228 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 229 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 230 erection of lt shunt capacitor 440 volt 40 kvar 3phase 50hz ip65 231 words...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32106801 development of distribution infrastructure work for loss reduction at district sambhal and j.p. nagar ( amroha ) in psvvnl under revamped reforms based and results linked, distribution sector scheme 1 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 2 pcc pole, 8.5 mtr. long 3 bolts and nuts for shackle insulators 4 lt shakle insulator 100x115 mm 5 d straps 6 lt xlpe armoured 3.5x50 sq. mm. cable 7 mid span jointing sleeves ( 50 sq. mm ) 8 insulating piercing connector ( 50 150 sq.mm ) 9 insulation mastic tape ( 2inc x 10 feet ) . 10 supply of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 11 supply of single of phase deep drawn distribution box with clamps and suitable lock and key arrangment 12 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 13 1x16 mm2 xlpe insulated al. cable for energising the street light 14 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 15 gi wire 6 swg 16 lt stay set ( 16 x 1800 mm ) 17 lt stay clamp with nut and bolt 18 stay wire 7 / 10 swg 19 lt stay insulator 20 stone pad ( 300x300x75mm ) 21 lt clamp with nut and bolt for pcc pole 22 angle for vertical arm l50x50x6 ( type a ) 23 angle for vertical arm l50x50x6 ( type b ) 24 top clamp for vertical arm ( type a ) 25 top clamp for vertical arm ( type b ) 26 bottom clamp for vertical arm ( type a ) 27 bottom clamp for vertical arm ( type b ) 28 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 29 pvc 2c x 6 sq.mm. armoured cable for service connection 30 polycarbonated box for single phase consumer 31 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 32 pvc 4c x 16 sq.mm. armoured cable for service connection 33 polycarbonated box for three phase consumer 34 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 35 pcc pole, 8.5 mtr. long 36 stone pad ( 300x300x75mm ) 37 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 38 gi wire 6 swg 39 lt stay set ( 16 x 1800 mm ) 40 lt stay clamp with nut and bolt 41 stay wire 7 / 10 swg 42 lt stay insulator 43 dead end clamps with i hook ( insulated ) 44 suspension clamp with i hook 45 pole clamps with nut and bolt 46 holding clamp for round pole with nut and bolt 47 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 48 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 49 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 50 lt abc of 3x50+1x35+1x16 sq. mm 51 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 52 1x16 mm2 xlpe insulated al. cable for energising the street light 53 end cap for lt ab cable 54 pg clamps 55 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 56 pcc pole, 8.5 mtr. long 57 stone pad ( 300x300x75mm ) 58 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 59 gi wire 6 swg 60 lt stay set ( 16 x 1800 mm ) 61 lt stay clamp with nut and bolt 62 stay wire 7 / 10 swg 63 lt stay insulator 64 dead end clamps with i hook ( insulated ) 65 suspension clamp with i hook 66 pole clamps with nut and bolt 67 holding clamp for round pole with nut and bolt 68 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 69 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 70 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 71 lt abc of 3x95+1x70+1x16 sq. mm 72 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 73 1x16 mm2 xlpe insulated al. cable for energising the street light 74 end cap for lt ab cable 75 pg clamps 76 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 77 pcc pole, 8.5 mtr. long 78 stone pad ( 300x300x75mm ) 79 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 80 gi wire 6 swg 81 lt stay set ( 16 x 1800 mm ) 82 lt stay clamp with nut and bolt 83 stay wire 7 / 10 swg 84 lt stay insulator 85 dead end clamps with i hook ( insulated ) 86 suspension clamp with i hook 87 pole clamps with nut and bolt 88 holding clamp for round pole with nut and bolt 89 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 90 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 91 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 92 lt abc of 3x120+1x95+1x16 sq. mm 93 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 94 1x16 mm2 xlpe insulated al. cable for energising the street light 95 end cap for lt ab cable 96 pg clamps 97 feeder bifurcation ( 11 kv line ) 98 11kv new line on 11 mtr. st pole with acsr dog conductor ( feeder bifurcation 11 kv line ) 99 11 kv polymer disc insulator b&s type 70 kn 100 disc fitting b&s type 70 kn 101 11 kv composite polymer pin insulator with nut and washers 102 11kv smc danger board with clamp, bolts & nuts 103 11kv smc number plate for clamp with n&b 104 11 kv stay set ( 16 x 1800 mm ) 105 11 kv stay clamp with nut and bolt 106 stay wire 7 / 10 swg 107 11 kv stay insulator 108 acsr dog conductor 109 p.g. clamp for acsr dog / raccoon 110 armour rod with ferrule for acsr dog / panther / raccoon helical performed 111 11 mtr. stp 112 13 mtr. stp 113 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 114 aluminium binding wire 6 swg 115 aluminium jointing sleeves 116 g.i. barbed wire 117 gi wire 6 swg 118 gi wire 8 swg 119 gi wire 16 swg 120 eye bolt 121 turn buckle 122 red oxide paint 123 aluminium paint 124 11kv e bracket with n&b 125 11kv `f bracket with n&b 126 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 127 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 128 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 129 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 130 cross arm holding clamp with nuts & bolts 131 v type cross arm for 11kv line, 100x50x6 mm, gi 132 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 133 gi guarding angle iron 75x75x6 mm 3010 mm long 134 stone pad ( 300x300x75mm ) 135 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 136 11 kv polymer disc insulator b&s type 70 kn 137 disc fitting b&s type 70 kn 138 11 kv composite polymer pin insulator with nut and washers 139 11kv smc danger board with clamp, bolts & nuts 140 11kv smc number plate for clamp with n&b 141 11 kv stay set ( 16 x 1800 mm ) 142 11 kv stay clamp with nut and bolt 143 stay wire 7 / 10 swg 144 11 kv stay insulator 145 acsr dog conductor 146 p.g. clamp for acsr dog / raccoon 147 armour rod with ferrule for acsr dog / panther / raccoon helical performed 148 pcc pole, 8.5 mtr. long 149 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 150 aluminium binding wire 6 swg 151 aluminium jointing sleeves 152 g.i. barbed wire 153 gi wire 6 swg 154 gi wire 8 swg 155 gi wire 16 swg 156 eye bolt 157 turn buckle 158 11kv e bracket with n&b 159 11kv `f bracket with n&b 160 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 161 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 162 cross arm holding clamp with nuts & bolts 163 v type cross arm for 11kv line, 100x50x6 mm, gi 164 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 165 gi guarding angle iron 75x75x6 mm 3010 mm long 166 stone pad ( 300x300x75mm ) 167 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 168 11 kv railway crossing 169 11kv 3x185 mm2xlpe cable 170 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 171 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 172 cable route marker 173 g.i. pipe 6 dia . 174 11 mtr. stp 175 stone pad ( 300x300x75mm ) 176 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 177 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 178 11 kv polymer disc insulator b&s type 70 kn 179 disc fitting b&s type 70 kn 180 p.g. clamp for acsr dog / raccoon 181 11kv smc number plate for clamp with n&b 182 11kv smc danger board with clamp, bolts & nuts 183 g.i. barbed wire 184 aluminium binding wire 6 swg 185 aluminium paint 186 red oxide paint 187 11 kvstay set ( 16 x 1800 mm ) 188 11 kv stay clamp with nut and bolt 189 stay wire 7 / 10 swg 190 11 kv stay insulator 191 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 192 gi wire 6 swg 193 nhai / state highway crossing 194 11kv 3x185 mm2xlpe cable 195 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 196 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 197 cable route marker 198 g.i. pipe 6 dia . 199 11 mtr. stp 200 stone pad ( 300x300x75mm ) 201 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 202 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 203 11 kv polymer disc insulator b&s type 70 kn 204 disc fitting b&s type 70 kn 205 p.g. clamp for acsr dog / raccoon 206 11kv smc number plate for clamp with n&b 207 11kv smc danger board with clamp, bolts & nuts 208 g.i. barbed wire 209 aluminium binding wire 6 swg 210 aluminium paint 211 red oxide paint 212 11 kv stay set ( 16 x 1800 mm ) 213 11 kv stay clamp with nut and bolt 214 stay wire 7 / 10 swg 215 11 kv stay insulator 216 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 217 gi wire 6 swg 218 augumentation / reconductoring of 33 kv overhead line with dog conductor 219 acsr dog conductor 220 pcc pole, 9.0 mtr. long 221 11 mtr. stp 222 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 223 gi wire 6 swg 224 33 kv composite polymer pin insulator with nut and washers 225 aluminium paint 226 red oxide paint 227 33kv smc danger board with clamp and n&b 228 33kv smc number plate with clampand n&b 229 stone pad ( 300x300x75mm ) 230 g.i. barbed wire 231 33kv e bracket with n&b 232 33kv f bracket with n&b 233 v type cross arm for 33kv line 100x50x6 mm, gi 234 cross arm holding clamp with nuts & bolts 235 33 kv polymer disc insulator b&s type 70 kn 236 disc fitting b&s type 70 kn 237 33 kv stay set 238 33 kv stay clamp with nut and bolt 239 stay wire 7 / 8 swg 240 33 kv stay insulator 241 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 242 acsr dog conductor 243 11 kv polymer disc insulator b&s type 70 kn 244 disc fitting b&s type 70 kn 245 11 kv composite polymer pin insulator with nut and washers 246 11kv smc danger board with clamp, bolts & nuts 247 11kv smc number plate for clamp with n&b 248 11 kv stay set ( 16 x 1800 mm ) 249 11 kv stay clamp with nut and bolt 250 stay wire 7 / 10 swg 251 11 kv stay insulator 252 p.g. clamp for acsr dog / raccoon 253 armour rod with ferrule for acsr dog / panther / raccoon helical performed 254 pcc pole, 8.5 mtr. long 255 11 mtr. stp 256 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 257 aluminium binding wire 6 swg 258 aluminium jointing sleeves 259 g.i. barbed wire 260 gi wire 6 swg 261 gi wire 8 swg 262 gi wire 16 swg 263 eye bolt 264 turn buckle 265 red oxide paint 266 aluminium paint 267 11kv `f bracket with n&b 268 cross arm holding clamp with nuts & bolts 269 v type cross arm for 11kv line, 100x50x6 mm, gi 270 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 271 stone pad ( 300x300x75mm ) 272 11 kv agriculture feeder segregation & feeder splitting due to overloading 273 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 274 acsr rabbit conductor 275 11kv polymer disc insulator t&c type 45 kn 276 disc fittings t&c type 45 kn 277 11 kv composite polymer pin insulator with nut and washers 278 11kv smc danger board with clamp, bolts & nuts 279 11kv smc number plate for clamp with n&b 280 11 kv stay set ( 16 x 1800 mm ) 281 11 kv stay clamp with nut and bolt 282 stay wire 7 / 10 swg 283 11 kv stay insulator 284 pg clamps 285 armour rod with ferrule for acsr dog / panther / raccoon helical performed 286 pcc pole, 8.5 mtr. long 287 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 288 aluminium binding wire 6 swg 289 aluminium jointing sleeves 290 g.i. barbed wire 291 gi wire 6 swg 292 gi wire 8 swg 293 gi wire 16 swg 294 eye bolt 295 turn buckle 296 11kv e bracket with n&b 297 11kv `f bracket with n&b 298 gi top channel 100x50x2240 mm. 299 clamp with nuts & bolts for 1300 mm long gi channel 300 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 301 gi top channel 100x50x6, 1525 mm long 302 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 303 cross arm holding clamp with nuts & bolts 304 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 305 v type cross arm for 11kv line, 65x65x6 mm, gi angle 306 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 307 stone pad ( 300x300x75mm ) 308 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 309 pcc pole, 8.5 mtr. long 310 stone pad ( 300x300x75mm ) 311 lt clamp with nut and bolt for pcc pole 312 lt shakle insulator 100x115 mm 313 bolts and nuts for shackle insulators 314 acsr rabbit conductor 315 aluminium jointing sleeves 316 aluminium binding wire 6 swg 317 earth wire clamp 318 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 319 gi wire 6 swg 320 lt stay set ( 16 x 1800 mm ) 321 lt stay clamp with nut and bolt 322 stay wire 7 / 10 swg 323 lt stay insulator 324 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 325 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 326 pcc pole, 8.5 mtr. long 327 stone pad ( 300x300x75mm ) 328 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 329 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 330 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 331 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 332 gi channel 125x65x6, 1300mm ( tee off ) 333 clamp with nuts & bolts for 1300 mm long gi channel 334 11kv polymer disc insulator t&c type 45 kn 335 disc fittings t&c type 45 kn 336 11 kv composite polymer pin insulator with nut and washers 337 11kv tpmo complete set 338 11kv do fuse set ( 3 phase ) 339 11kv lightening arrestor 340 g.i. barbed wire 341 11kv smc danger board with clamp, bolts & nuts 342 deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 343 lt stay set ( 16 x 1800 mm ) 344 lt stay clamp with nut and bolt 345 stay wire 7 / 10 swg 346 lt stay insulator 347 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 348 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 349 lt pvc cable3.5x150 / 70sq.mm. 350 acsr weasel conductor 351 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 352 gi wire 6 swg 353 gi strip 25x3 mm 354 gi angle 100x50x2028mm ( fordistribution box ) ) 355 al. crimping lugs 150 sq.mm. 356 al. crimping lugs 70 sq.mm. 357 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 358 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 359 11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 360 pcc pole, 8.5 mtr. long 361 stone pad ( 300x300x75mm ) 362 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 363 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 364 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 365 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 366 gi channel 125x65x6, 1300mm ( tee off ) 367 clamp with nuts & bolts for 1300 mm long gi channel 368 11kv polymer disc insulator t&c type 45 kn 369 disc fittings t&c type 45 kn 370 11 kv composite polymer pin insulator with nut and washers 371 11kv tpmo complete set 372 11kv do fuse set ( 3 phase ) 373 11kv lightening arrestor 374 g.i. barbed wire 375 11kv smc danger board with clamp, bolts & nuts 376 deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 377 lt stay set ( 16 x 1800 mm ) 378 lt stay clamp with nut and bolt 379 stay wire 7 / 10 swg 380 lt stay insulator 381 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 382 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 383 lt pvc cable3.5x70 / 35sq.mm. 384 acsr weasel conductor 385 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 386 gi wire 6 swg 387 gi strip 25x3 mm 388 gi angle 100x50x2028mm ( fordistribution box ) ) 389 al. crimping lugs 70 sq.mm. 390 al. crimping lugs 35 sq.mm. 391 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 392 construction of new 25 kva, 11 / 0.433kv distribution transformer s / s 393 11 / 0.44 kv 25 kva transformer ( four star rating, level ii ) 394 pcc pole, 8.5 mtr. long 395 stone pad ( 300x300x75mm ) 396 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 397 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 398 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 399 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 400 gi channel 125x65x6, 1300mm ( tee off ) 401 clamp with nuts & bolts for 1300 mm long gi channel 402 11kv polymer disc insulator t&c type 45 kn 403 disc fittings t&c type 45 kn 404 11 kv composite polymer pin insulator with nut and washers 405 11kv tpmo complete set 406 11kv do fuse set ( 3 phase ) 407 11kv lightening arrestor 408 g.i. barbed wire 409 11kv smc danger board with clamp, bolts & nuts 410 deep drawn distribution boxas per technical specifications for 3 ph 25 kva dtr 411 lt stay set ( 16 x 1800 mm ) 412 lt stay clamp with nut and bolt 413 stay wire 7 / 10 swg 414 lt stay insulator 415 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 416 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 417 lt xlpe insulated unarmoured 4x25 sq. mm.cable 418 acsr weasel conductor 419 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 420 gi wire 6 swg 421 gi strip 25x3 mm 422 gi angle 100x50x2028mm ( fordistribution box ) ) 423 al. crimping lugs 25 sq.mm. 424 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 425 installation of 11 kv outgoing vcb for feeder segreration 426 11kv outgoing ctr 400 / 200 / 5a 350 mva 427 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 428 11kv 3x185 mm2xlpe cable 429 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 430 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 431 11 mtr. stp 432 gi top channel 100x50x2240 mm. 433 stone pad ( 300x300x75mm ) 434 11 kv polymer disc insulator b&s type 70 kn 435 disc fitting b&s type 70 kn 436 11 kv composite polymer pin insulator with nut and washers 437 p.g. clamp for acsr dog / raccoon 438 11kv e bracket with n&b 439 11kv smc number plate for clamp with n&b 440 11kv smc danger board with clamp, bolts & nuts 441 gi channel 125x65x2028 mm long ( dropper for fuse set ) 442 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 443 11kv tpmo complete set 444 11kv do fuse set ( 3 phase ) 445 11kv lightening arrestor 446 g.i. barbed wire 447 aluminium binding wire 6 swg 448 aluminium paint 449 red oxide paint 450 11 kv stay set ( 16 x 1800 mm ) 451 11 kv stay clamp with nut and bolt 452 stay wire 7 / 10 swg 453 11 kv stay insulator 454 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 455 gi strip 50x6 mm 456 gi wire 6 swg 457 g.i. pipe 6 dia . 458 11 kv railway crossing 459 11kv 3x185 mm2xlpe cable 460 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 461 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 462 cable route marker 463 g.i. pipe 6 dia . 464 11 mtr. stp 465 stone pad ( 300x300x75mm ) 466 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 467 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 468 11 kv polymer disc insulator b&s type 70 kn 469 disc fitting b&s type 70 kn 470 p.g. clamp for acsr dog / raccoon 471 11kv smc number plate for clamp with n&b 472 11kv smc danger board with clamp, bolts & nuts 473 g.i. barbed wire 474 aluminium binding wire 6 swg 475 aluminium paint 476 red oxide paint 477 11 kvstay set ( 16 x 1800 mm ) 478 11 kv stay clamp with nut and bolt 479 stay wire 7 / 10 swg 480 11 kv stay insulator 481 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 482 gi wire 6 swg 483 nhai / state highway crossing 484 11kv 3x185 mm2xlpe cable 485 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 486 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 487 cable route marker 488 g.i. pipe 6 dia . 489 11 mtr. stp 490 stone pad ( 300x300x75mm ) 491 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 492 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 493 11 kv polymer disc insulator b&s type 70 kn 494 disc fitting b&s type 70 kn 495 p.g. clamp for acsr dog / raccoon 496 11kv smc number plate for clamp with n&b 497 11kv smc danger board with clamp, bolts & nuts 498 g.i. barbed wire 499 aluminium binding wire 6 swg 500 aluminium paint 501 red oxide paint 502 11 kv stay set ( 16 x 1800 mm ) 503 11 kv stay clamp with nut and bolt 504 stay wire 7 / 10 swg 505 11 kv stay insulator 506 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 507 gi wire 6 swg 508 requirement of extra ab cable for new additional ckt at dts 509 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 510 pcc pole, 8.5 mtr. long 511 11 mtr. stp 512 stone pad ( 300x300x75mm ) 513 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 514 gi wire 6 swg 515 lt stay set ( 16 x 1800 mm ) 516 lt stay clamp with nut and bolt 517 stay wire 7 / 10 swg 518 lt stay insulator 519 dead end clamps with i hook ( insulated ) 520 suspension clamp with i hook 521 pole clamps with nut and bolt 522 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 523 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 524 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 525 lt abc of 3x50+1x35+1x16 sq. mm 526 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 527 end cap for lt ab cable 528 pg clamps 529 1x16 mm2 xlpe insulated al. cable for energising the street light 530 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 531 pcc pole, 8.5 mtr. long 532 11 mtr. stp 533 stone pad ( 300x300x75mm ) 534 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 535 gi wire 6 swg 536 lt stay set ( 16 x 1800 mm ) 537 lt stay clamp with nut and bolt 538 stay wire 7 / 10 swg 539 lt stay insulator 540 dead end clamps with i hook ( insulated ) 541 suspension clamp with i hook 542 pole clamps with nut and bolt 543 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 544 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 545 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 546 lt abc of 3x95+1x70+1x16 sq. mm 547 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 548 end cap for lt ab cable 549 pg clamps 550 1x16 mm2 xlpe insulated al. cable for energising the street light 551 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 552 pcc pole, 8.5 mtr. long 553 11 mtr. stp 554 stone pad ( 300x300x75mm ) 555 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 556 gi wire 6 swg 557 lt stay set ( 16 x 1800 mm ) 558 lt stay clamp with nut and bolt 559 stay wire 7 / 10 swg 560 lt stay insulator 561 dead end clamps with i hook ( insulated ) 562 suspension clamp with i hook 563 pole clamps with nut and bolt 564 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 565 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 566 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 567 lt abc of 3x120+1x95+1x16 sq. mm 568 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 569 end cap for lt ab cable 570 pg clamps 571 1x16 mm2 xlpe insulated al. cable for energising the street light 572 additional items that may be required for completion of work 573 3x120 sq. mm 11 kv ab cable 574 11kv polymer disc insulator with fitting for 11 kvabc 575 11kv polymer disc insulators with i hook 576 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 577 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 578 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 579 33kv 3x300 mm2xlpe cable 580 lt xlpe insulated unarmoured 1x50 sq. mm. cable 581 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 582 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 583 loop guard complete, 3 phase 584 spacers lt pvc 585 mid span jointing sleeves ( 95 sq. mm ) 586 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 587 supply of on / off switch for street light connections 588 height raising channel 100x50, 2240 mm long 589 back clamp for height raising channel holding clamps with bolts & nuts 590 cable jointing kit straight through ( 3x185 sqmm ) 591 cable jointing kit straight through ( 3x300sqmm ) 592 extra prefabricated gi items like clamp, channel, angle with nut & bolt 593 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 594 erection of pcc pole, 8.5 mtr. long 595 fixing of bolts and nuts for shackle insulators 596 fixing of lt shakle insulator 100x115 mm 597 fixing of d straps 598 stringing of lt xlpe armoured 3.5x50 sq. mm. cable 599 fixing of mid span jointing sleeves ( 120 sq. mm ) 600 fixing of insulating piercing connector ( 50 150 sq.mm ) 601 fixing of insulation mastic tape ( 2inc x 10 feet ) . 602 fixing of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 603 fixing of single phase deep drawn distribution box with clamps and suitable lock and key arrangment 604 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 605 1x16 mm2 xlpe insulated al. cable for energising the street light 606 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 607 gi wire 6 swg 608 erection of lt stay set ( 16 x 1800 mm ) 609 fixing of lt stay clamp with nut and bolt 610 erection of stay wire 7 / 10 swg 611 fixing of lt stay insulator 612 concreting of stay set ( 16x 1800 mm ) 613 stone pad ( 300x300x75mm ) 614 fixing of lt clamp with nut and bolt for pcc pole 615 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 616 concreting of pole / support ( 0.268 cu.m. ) 617 fixing of angle for vertical arm l50x50x6 ( type a ) 618 fixing of angle for vertical arm l50x50x6 ( type b ) 619 fixing of top clamp for vertical arm ( type a ) 620 fixing of top clamp for vertical arm ( type b ) 621 fixing of bottom clamp for vertical arm ( type a ) 622 fixing of bottom clamp for vertical arm ( type b ) 623 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 624 stringing of pvc 2c x 6 sq.mm. armoured cable for service connection 625 dismanting of old line service cable and connection of new armoured cable 626 fixing of polycarbonated box for single phase consumer 627 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 628 stringing of pvc 4c x 16 sq.mm. armoured cable for service connection 629 dismanting of old line service cable and connection of new armoured cable 630 fixing of polycarbonated box for three phase consumer 631 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 632 erection of pcc pole, 8.5 mtr. long 633 stone pad ( 300x300x75mm ) 634 concreting of pole / support ( 0.268 cu.m. ) 635 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 636 gi wire 6 swg 637 erection of lt stay set ( 16 x 1800 mm ) 638 fixing of lt stay clamp with nut and bolt 639 erection of stay wire 7 / 10 swg 640 fixing of lt stay insulator 641 concreting of stay set ( 16x 1800 mm ) 642 fixing of dead end clamps with i hook ( insulated ) 643 fixing of suspension clamp with i hook 644 fixing of pole clamps with nut and bolt 645 fixing of holding clamp for round pole with nut and bolt 646 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 647 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 648 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 649 stringing of lt abc of 3x50+1x35+1x16 sq. mm 650 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 651 1x16 mm2 xlpe insulated al. cable for energising the street light 652 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 653 fixing of end cap for lt ab cable 654 fixing of pg clamps 655 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 656 erection of pcc pole, 8.5 mtr. long 657 stone pad ( 300x300x75mm ) 658 concreting of pole / support ( 0.268 cu.m. ) 659 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 660 gi wire 6 swg 661 erection of lt stay set ( 16 x 1800 mm ) 662 fixing of lt stay clamp with nut and bolt 663 erection of stay wire 7 / 10 swg 664 fixing of lt stay insulator 665 concreting of stay set ( 16x 1800 mm ) 666 dead end clamps with i hook ( insulated ) 667 fixing of suspension clamp with i hook 668 fixing of pole clamps with nut and bolt 669 holding clamp for round pole with nut and bolt 670 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 671 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 672 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 673 stringing of lt abc of 3x95+1x70+1x16 sq. mm 674 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 675 1x16 mm2 xlpe insulated al. cable for energising the street light 676 end cap for lt ab cable 677 fixing of pg clamps 678 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 679 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 680 erection of pcc pole, 8.5 mtr. long 681 stone pad ( 300x300x75mm ) 682 concreting of pole / support ( 0.268 cu.m. ) 683 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 684 gi wire 6 swg 685 erection of lt stay set ( 16 x 1800 mm ) 686 fixing of lt stay clamp with nut and bolt 687 erection of stay wire 7 / 10 swg 688 fixing of lt stay insulator 689 concreting of stay set ( 16x 1800 mm ) 690 dead end clamps with i hook ( insulated ) 691 fixing of suspension clamp with i hook 692 fixing of pole clamps with nut and bolt 693 holding clamp for round pole with nut and bolt 694 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 695 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 696 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 697 stringing of lt abc of 3x120+1x95+1x16 sq. mm 698 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 699 1x16 mm2 xlpe insulated al. cable for energising the street light 700 end cap for lt ab cable 701 fixing of pg clamps 702 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 703 feeder bifurcation ( 11 kv line ) 704 11kv new line on 11 mtr. st pole with acsr dog conductor 705 erection of 11 kv polymer disc insulator b&s type 70 kn 706 erection of disc fitting b&s type 70 kn 707 erection of 11 kv composite polymer pin insulator with nut and washers 708 fixing of 11kv smc danger board with clamp, bolts & nuts 709 fixing of 11kv smc number plate for clamp with n&b 710 erection of 11 kv stay set ( 16 x 1800 mm ) 711 fixing of 11 kv stay clamp with nut and bolt 712 erection of stay wire 7 / 10 swg 713 fixing of 11 kv stay insulator 714 concreting of stay set ( 16x 1800 mm ) 715 stringing of acsr dog conductor 716 fixing of p.g. clamp for acsr dog / raccoon 717 armour rod with ferrule for acsr dog / panther / raccoon helical performed 718 erection of 11 mtr. stp 719 erection of 13 mtr. stp 720 concreting of pole / support ( 0.44 cu.m. ) 721 concreting of pole ( 0.64 cu.m. ) 722 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 723 aluminium binding wire 6 swg 724 aluminium jointing sleeves 725 g.i. barbed wire 726 gi wire 6 swg 727 gi wire 8 swg 728 gi wire 16 swg 729 eye bolt 730 turn buckle 731 painting of st pole with red oxide paint 732 painting of st pole with aluminium paint 733 erection of 11kv e bracket with n&b 734 erection of 11kv `f bracket with n&b 735 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 736 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 737 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 738 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 739 cross arm holding clamp with nuts & bolts 740 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 741 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 742 gi guarding angle iron 75x75x6 mm 3010 mm long 743 tree cutting compensation 744 stone pad ( 300x300x75mm ) 745 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 746 erection of 11 kv polymer disc insulator b&s type 70 kn 747 erection of disc fitting b&s type 70 kn 748 erection of 11 kv composite polymer pin insulator with nut and washers 749 fixing of 11kv smc danger board with clamp, bolts & nuts 750 fixing of 11kv smc number plate for clamp with n&b 751 erection of 11 kv stay set ( 16 x 1800 mm ) 752 fixing of 11 kv stay clamp with nut and bolt 753 erection of stay wire 7 / 10 swg 754 fixing of 11 kv stay insulator 755 concreting of stay set ( 16x 1800 mm ) 756 stringing of acsr dog conductor 757 fixing of p.g. clamp for acsr dog / raccoon 758 armour rod with ferrule for acsr dog / panther / raccoon helical performed 759 erection of pcc pole, 8.5 mtr. long 760 concreting of pole / support ( 0.268 cu.m. ) 761 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 762 aluminium binding wire 6 swg 763 aluminium jointing sleeves 764 g.i. barbed wire 765 gi wire 6 swg 766 gi wire 8 swg 767 gi wire 16 swg 768 eye bolt 769 turn buckle 770 erection of 11kv e bracket with n&b 771 erection of 11kv `f bracket with n&b 772 gi top channel 125x65mm, 3200 mm with clamp, bolts, nuts and washers 773 gi angle 65x65x6mm, 4300 mm long bracing with 4 clamps, bolts, nuts and washers 774 cross arm holding clamp with nuts & bolts 775 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 776 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 777 gi guarding angle iron 75x75x6 mm 3010 mm long 778 tree cutting compensation 779 stone pad ( 300x300x75mm ) 780 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 781 11 kv railway crossing 782 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 783 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 784 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 785 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 786 cable route marker 787 g.i. pipe 6 dia . 788 erection of 11 mtr. stp 789 stone pad ( 300x300x75mm ) 790 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 791 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 792 erection of 11 kv polymer disc insulator b&s type 70 kn 793 erection of disc fitting b&s type 70 kn 794 fixing of p.g. clamp for acsr dog / raccoon 795 fixing of 11kv smc number plate for clamp with n&b 796 fixing of 11kv smc danger board with clamp, bolts & nuts 797 g.i. barbed wire 798 aluminium binding wire 6 swg 799 painting of st pole with aluminium paint 800 painting of st pole with red oxide paint 801 erection of 11 kvstay set ( 16 x 1800 mm ) 802 fixing of 11 kv stay clamp with nut and bolt 803 erection of stay wire 7 / 10 swg 804 fixing of 11 kv stay insulator 805 concreting of stay set ( 16x 1800 mm ) 806 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 807 gi wire 6 swg 808 concreting of pole / support ( 0.44 cu.m. ) 809 railway crossing documentation, land and approval fee etc. 810 nhai / state highway crossing 811 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 812 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 813 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 814 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 815 cable route marker 816 g.i. pipe 6 dia . 817 erection of 11 mtr. stp 818 stone pad ( 300x300x75mm ) 819 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 820 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 821 erection of 11 kv polymer disc insulator b&s type 70 kn 822 disc fitting b&s type 70 kn 823 fixing of p.g. clamp for acsr dog / raccoon 824 fixing of 11kv smc number plate for clamp with n&b 825 fixing of 11kv smc danger board with clamp, bolts & nuts 826 g.i. barbed wire 827 aluminium binding wire 6 swg 828 painting of st pole with aluminium paint 829 painting of st pole with red oxide paint 830 erection of 11 kv stay set ( 16 x 1800 mm ) 831 fixing of 11 kv stay clamp with nut and bolt 832 erection of stay wire 7 / 10 swg 833 fixing of 11 kv stay insulator 834 concreting of stay set ( 16x 1800 mm ) 835 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 836 gi wire 6 swg 837 concreting of pole / support ( 0.44 cu.m. ) 838 nhai / state highway crossing documentation, land charges and approval fee etc. 839 road restoration charges 840 augumentation / reconductoring of 33 kv overhead line with dog conductor 841 stringing of acsr dog conductor 842 erection of pcc pole, 9.0 mtr. long 843 erection of 11 mtr. stp 844 concreting of pole / support ( 0.286 cu.m. ) 845 concreting of pole / support ( 0.44 cu.m. ) 846 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 847 gi wire 6 swg 848 erection of 33 kv composite polymer pin insulator with nut and washers 849 painting of st pole with aluminium paint 850 painting of st pole with red oxide paint 851 fixing of 33kv smc danger board with clamp and n&b 852 fixing of 33kv smc number plate with clampand n&b 853 stone pad ( 300x300x75mm ) 854 g.i. barbed wire 855 erection of 33kv e bracket with n&b 856 erection of 33kv f bracket with n&b 857 erection of v type cross arm for 33kv line 100x50x6 mm, gi 858 cross arm holding clamp with nuts & bolts 859 erection of 33 kv polymer disc insulator b&s type 70 kn 860 disc fitting b&s type 70 kn 861 erection of 33 kv stay set 862 fixing of 33 kv stay clamp with nut and bolt 863 erection of stay wire 7 / 8 swg 864 fixing of 33 kv stay insulator 865 concreting of 33 kv stay set 866 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 867 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 868 stringing of acsr dog conductor 869 erection of 11 kv polymer disc insulator b&s type 70 kn 870 disc fitting b&s type 70 kn 871 erection of 11 kv composite polymer pin insulator with nut and washers 872 fixing of 11kv smc danger board with clamp, bolts & nuts 873 fixing of 11kv smc number plate for clamp with n&b 874 erection of 11 kv stay set ( 16 x 1800 mm ) 875 fixing of 11 kv stay clamp with nut and bolt 876 erection of stay wire 7 / 10 swg 877 fixing of 11 kv stay insulator 878 concreting of stay set ( 16x 1800 mm ) 879 fixing of p.g. clamp for acsr dog / raccoon 880 armour rod with ferrule for acsr dog / panther / raccoon helical performed 881 erection of pcc pole, 8.5 mtr. long 882 erection of 11 mtr. stp 883 concreting of pole / support ( 0.268 cu.m. ) 884 concreting of pole / support ( 0.44 cu.m. ) 885 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 886 aluminium binding wire 6 swg 887 aluminium jointing sleeves 888 g.i. barbed wire 889 gi wire 6 swg 890 gi wire 8 swg 891 gi wire 16 swg 892 eye bolt 893 turn buckle 894 painting of st pole with red oxide paint 895 painting of st pole with aluminium paint 896 erection of 11kv `f bracket with n&b 897 cross arm holding clamp with nuts & bolts 898 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 899 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 900 stone pad ( 300x300x75mm ) 901 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 902 11 kv agriculture feeder segregation & feeder splitting due to overloading 903 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 904 stringing of acsr rabbit conductor 905 erection of 11kv polymer disc insulator t&c type 45 kn 906 disc fittings t&c type 45 kn 907 erection of 11 kv composite polymer pin insulator with nut and washers 908 fixing of 11kv smc danger board with clamp, bolts & nuts 909 fixing of 11kv smc number plate for clamp with n&b 910 erection of 11 kv stay set ( 16 x 1800 mm ) 911 fixing of 11 kv stay clamp with nut and bolt 912 erection of stay wire 7 / 10 swg 913 fixing of 11 kv stay insulator 914 concreting of stay set ( 16x 1800 mm ) 915 fixing of pg clamps 916 armour rod with ferrule for acsr dog / panther / raccoon helical performed 917 erection of pcc pole, 8.5 mtr. long 918 concreting of pole / support ( 0.268 cu.m. ) 919 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 920 aluminium binding wire 6 swg 921 aluminium jointing sleeves 922 g.i. barbed wire 923 gi wire 6 swg 924 gi wire 8 swg 925 gi wire 16 swg 926 eye bolt 927 turn buckle 928 erection of 11kv e bracket with n&b 929 erection of 11kv `f bracket with n&b 930 gi top channel 100x50x2240 mm. 931 clamp with nuts & bolts for 1300 mm long gi channel 932 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 933 gi top channel 100x50x6, 1525 mm long 934 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 935 cross arm holding clamp with nuts & bolts 936 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 937 erection of v type cross arm for 11kv line, 65x65x6 mm, gi angle 938 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 939 tree cutting compensation 940 stone pad ( 300x300x75mm ) 941 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 942 erection of pcc pole, 8.5 mtr. long 943 stone pad ( 300x300x75mm ) 944 lt clamp with nut and bolt for pcc pole 945 lt shakle insulator 100x115 mm 946 bolts and nuts for shackle insulators 947 concreting of pole / support ( 0.268 cu.m. ) 948 stringing of acsr rabbit conductor 949 aluminium jointing sleeves 950 aluminium binding wire 6 swg 951 earth wire clamp 952 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 953 gi wire 6 swg 954 erection of lt stay set ( 16 x 1800 mm ) 955 fixing of lt stay clamp with nut and bolt 956 erection of stay wire 7 / 10 swg 957 fixing of lt stay insulator 958 concreting of stay set ( 16x 1800 mm ) 959 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 960 installation of 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 961 erection of pcc pole, 8.5 mtr. long 962 stone pad ( 300x300x75mm ) 963 concreting of pole / support ( 0.268 cu.m. ) 964 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 965 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 966 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 967 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 968 gi channel 125x65x6, 1300mm ( tee off ) 969 clamp with nuts & bolts for 1300 mm long gi channel 970 erection of 11kv polymer disc insulator t&c type 45 kn 971 disc fittings t&c type 45 kn 972 erection of 11 kv composite polymer pin insulator with nut and washers 973 erection of 11kv tpmo complete set 974 erection of 11kv do fuse set ( 3 phase ) 975 erection of 11kv lightening arrestor 976 g.i. barbed wire 977 fixing of 11kv smc danger board with clamp, bolts & nuts 978 fixing of deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 979 erection of lt stay set ( 16 x 1800 mm ) 980 fixing of lt stay clamp with nut and bolt 981 erection of stay wire 7 / 10 swg 982 fixing of lt stay insulator 983 concreting of stay set ( 16x 1800 mm ) 984 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 985 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 986 lt pvc cable3.5x150 / 70sq.mm. 987 acsr weasel conductor 988 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 989 gi wire 6 swg 990 gi strip 25x3 mm 991 gi angle 100x50x2028mm ( fordistribution box ) ) 992 al. crimping lugs 150 sq.mm. 993 al. crimping lugs 70 sq.mm. 994 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 995 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 996 installation of11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 997 erection of pcc pole, 8.5 mtr. long 998 stone pad ( 300x300x75mm ) 999 concreting of pole / support ( 0.268 cu.m. ) 1000 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1001 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 1002 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1003 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 1004 gi channel 125x65x6, 1300mm ( tee off ) 1005 clamp with nuts & bolts for 1300 mm long gi channel 1006 erection of 11kv polymer disc insulator t&c type 45 kn 1007 disc fittings t&c type 45 kn 1008 erection of 11 kv composite polymer pin insulator with nut and washers 1009 erection of 11kv tpmo complete set 1010 erection of 11kv do fuse set ( 3 phase ) 1011 erection of 11kv lightening arrestor 1012 g.i. barbed wire 1013 fixing of 11kv smc danger board with clamp, bolts & nuts 1014 fixing of deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 1015 erection of lt stay set ( 16 x 1800 mm ) 1016 fixing of lt stay clamp with nut and bolt 1017 erection of stay wire 7 / 10 swg 1018 fixing of lt stay insulator 1019 concreting of stay set ( 16x 1800 mm ) 1020 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 1021 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 1022 lt pvc cable3.5x70 / 35sq.mm. 1023 acsr weasel conductor 1024 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1025 gi wire 6 swg 1026 gi strip 25x3 mm 1027 gi angle 100x50x2028mm ( fordistribution box ) ) 1028 al. crimping lugs 70 sq.mm. 1029 al. crimping lugs 35 sq.mm. 1030 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 1031 construction of new 25 kva, 11 / 0.433kv distribution transformer s / s 1032 installation of11 / 0.44 kv 25 kva transformer ( four star rating, level ii ) 1033 erection of pcc pole, 8.5 mtr. long 1034 stone pad ( 300x300x75mm ) 1035 concreting of pole / support ( 0.268 cu.m. ) 1036 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1037 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 1038 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1039 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 1040 gi channel 125x65x6, 1300mm ( tee off ) 1041 clamp with nuts & bolts for 1300 mm long gi channel 1042 erection of 11kv polymer disc insulator t&c type 45 kn 1043 disc fittings t&c type 45 kn 1044 erection of 11 kv composite polymer pin insulator with nut and washers 1045 erection of 11kv tpmo complete set 1046 erection of 11kv do fuse set ( 3 phase ) 1047 erection of 11kv lightening arrestor 1048 g.i. barbed wire 1049 fixing of 11kv smc danger board with clamp, bolts & nuts 1050 fixing of deep drawn distribution boxas per technical specifications for 3 ph 25 kva dtr 1051 erection of lt stay set ( 16 x 1800 mm ) 1052 fixing of lt stay clamp with nut and bolt 1053 erection of stay wire 7 / 10 swg 1054 fixing of lt stay insulator 1055 concreting of stay set ( 16x 1800 mm ) 1056 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 1057 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 1058 lt xlpe insulated unarmoured 4x25 sq. mm.cable 1059 acsr weasel conductor 1060 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1061 gi wire 6 swg 1062 gi strip 25x3 mm 1063 gi angle 100x50x2028mm ( fordistribution box ) ) 1064 al. crimping lugs 25 sq.mm. 1065 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 1066 installation of 11 kv outgoing vcb for feeder segreration 1067 installation of 11kv outgoing ctr 400 / 200 / 5a 350 mva 1068 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 1069 11kv 3x185 mm2xlpe cable 1070 laying of 11 kv cable including cost of sand & bricks 1071 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1072 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1073 erection of 11 mtr. stp 1074 gi top channel 100x50x2240 mm. 1075 stone pad ( 300x300x75mm ) 1076 erection of 11 kv polymer disc insulator b&s type 70 kn 1077 disc fitting b&s type 70 kn 1078 erection of 11 kv composite polymer pin insulator with nut and washers 1079 fixing of p.g. clamp for acsr dog / raccoon 1080 erection of 11kv e bracket with n&b 1081 fixing of 11kv smc number plate for clamp with n&b 1082 fixing of 11kv smc danger board with clamp, bolts & nuts 1083 gi channel 125x65x2028 mm long ( dropper for fuse set ) 1084 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1085 erection of 11kv tpmo complete set 1086 erection of 11kv do fuse set ( 3 phase ) 1087 erection of 11kv lightening arrestor 1088 g.i. barbed wire 1089 aluminium binding wire 6 swg 1090 painting of st pole with aluminium paint 1091 painting of st pole with red oxide paint 1092 erection of 11 kv stay set ( 16 x 1800 mm ) 1093 fixing of 11 kv stay clamp with nut and bolt 1094 erection of stay wire 7 / 10 swg 1095 fixing of 11 kv stay insulator 1096 concreting of stay set ( 16x 1800 mm ) 1097 concreting of pole / support ( 0.44 cu.m. ) 1098 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1099 gi strip 50x6 mm 1100 gi wire 6 swg 1101 g.i. pipe 6 dia . 1102 control room extension 1103 extension of existing substationcontrol room building. ( as per annexure attached in tender documents. ) 1104 11 kv railway crossing 1105 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1106 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1107 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1108 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1109 cable route marker 1110 g.i. pipe 6 dia . 1111 erection of 11 mtr. stp 1112 stone pad ( 300x300x75mm ) 1113 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1114 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1115 erection of 11 kv polymer disc insulator b&s type 70 kn 1116 disc fitting b&s type 70 kn 1117 fixing of p.g. clamp for acsr dog / raccoon 1118 fixing of 11kv smc number plate for clamp with n&b 1119 fixing of 11kv smc danger board with clamp, bolts & nuts 1120 g.i. barbed wire 1121 aluminium binding wire 6 swg 1122 painting of st pole with aluminium paint 1123 painting of st pole with red oxide paint 1124 erection of 11 kvstay set ( 16 x 1800 mm ) 1125 fixing of 11 kv stay clamp with nut and bolt 1126 erection of stay wire 7 / 10 swg 1127 fixing of 11 kv stay insulator 1128 concreting of stay set ( 16x 1800 mm ) 1129 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1130 gi wire 6 swg 1131 concreting of pole / support ( 0.44 cu.m. ) 1132 railway crossing documentation, land and approval fee etc. 1133 nhai / state highway crossing 1134 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1135 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1136 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1137 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1138 cable route marker 1139 g.i. pipe 6 dia . 1140 erection of 11 mtr. stp 1141 stone pad ( 300x300x75mm ) 1142 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1143 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1144 erection of 11 kv polymer disc insulator b&s type 70 kn 1145 disc fitting b&s type 70 kn 1146 fixing of p.g. clamp for acsr dog / raccoon 1147 fixing of 11kv smc number plate for clamp with n&b 1148 fixing of 11kv smc danger board with clamp, bolts & nuts 1149 g.i. barbed wire 1150 aluminium binding wire 6 swg 1151 painting of st pole with aluminium paint 1152 painting of st pole with red oxide paint 1153 erection of 11 kv stay set ( 16 x 1800 mm ) 1154 fixing of 11 kv stay clamp with nut and bolt 1155 erection of stay wire 7 / 10 swg 1156 fixing of 11 kv stay insulator 1157 concreting of stay set ( 16x 1800 mm ) 1158 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1159 gi wire 6 swg 1160 concreting of pole / support ( 0.44 cu.m. ) 1161 nhai / state highway crossing documentation, land charges and approval fee etc. 1162 road restoration charges 1163 requirement of extra ab cable for new additional ckt at dts 1164 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 1165 erection of pcc pole, 8.5 mtr. long 1166 erection of 11 mtr. stp 1167 stone pad ( 300x300x75mm ) 1168 concreting of pole / support ( 0.268 cu.m. ) 1169 concreting of pole / support ( 0.44 cu.m. ) 1170 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1171 gi wire 6 swg 1172 erection of lt stay set ( 16 x 1800 mm ) 1173 fixing of lt stay clamp with nut and bolt 1174 erection of stay wire 7 / 10 swg 1175 fixing of lt stay insulator 1176 concreting of stay set ( 16x 1800 mm ) 1177 dead end clamps with i hook ( insulated ) 1178 fixing of suspension clamp with i hook 1179 fixing of pole clamps with nut and bolt 1180 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1181 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1182 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1183 stringing of lt abc of 3x50+1x35+1x16 sq. mm 1184 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1185 end cap for lt ab cable 1186 fixing of pg clamps 1187 1x16 mm2 xlpe insulated al. cable for energising the street light 1188 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 1189 erection of pcc pole, 8.5 mtr. long 1190 erection of 11 mtr. stp 1191 stone pad ( 300x300x75mm ) 1192 concreting of pole / support ( 0.268 cu.m. ) 1193 concreting of pole / support ( 0.44 cu.m. ) 1194 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1195 gi wire 6 swg 1196 erection of lt stay set ( 16 x 1800 mm ) 1197 fixing of lt stay clamp with nut and bolt 1198 erection of stay wire 7 / 10 swg 1199 fixing of lt stay insulator 1200 concreting of stay set ( 16x 1800 mm ) 1201 dead end clamps with i hook ( insulated ) 1202 fixing of suspension clamp with i hook 1203 fixing of pole clamps with nut and bolt 1204 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1205 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1206 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1207 stringing of lt abc of 3x95+1x70+1x16 sq. mm 1208 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1209 end cap for lt ab cable 1210 fixing of pg clamps 1211 1x16 mm2 xlpe insulated al. cable for energising the street light 1212 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 1213 erection of pcc pole, 8.5 mtr. long 1214 erection of 11 mtr. stp 1215 stone pad ( 300x300x75mm ) 1216 concreting of pole / support ( 0.268 cu.m. ) 1217 concreting of pole / support ( 0.44 cu.m. ) 1218 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1219 gi wire 6 swg 1220 erection of lt stay set ( 16 x 1800 mm ) 1221 fixing of lt stay clamp with nut and bolt 1222 erection of stay wire 7 / 10 swg 1223 fixing of lt stay insulator 1224 concreting of stay set ( 16x 1800 mm ) 1225 dead end clamps with i hook ( insulated ) 1226 fixing of suspension clamp with i hook 1227 fixing of pole clamps with nut and bolt 1228 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1229 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1230 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1231 stringing of lt abc of 3x120+1x95+1x16 sq. mm 1232 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1233 end cap for lt ab cable 1234 fixing of pg clamps 1235 1x16 mm2 xlpe insulated al. cable for energising the street light 1236 additional items that may be required for completion of work 1237 3x120 sq. mm 11 kv ab cable 1238 11kv polymer disc insulator with fitting for 11 kvabc 1239 11kv polymer disc insulators with i hook 1240 erection & concreting of extra stud pole complete with clamps, 1241 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 1242 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 1243 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 1244 lt xlpe insulated unarmoured 1x50 sq. mm. cable 1245 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 1246 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 1247 laying of 3x300 sq. mm. 33 kv xlpe insulated cable underground in hdpe pipe or trenches ( for railway / road crossing ) 1248 drilling & laying of ht underground cable using hdd method without using hdpe pipe 1249 loop guard complete, 3 phase 1250 spacers lt pvc 1251 mid span jointing sleeves ( 95 sq. mm ) 1252 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 1253 fixing of on / off switch for street light connections 1254 mounting of cable on dp structure ( including loop and riser ) 1255 height raising channel 100x50, 2240 mm long 1256 back clamp for height raising channel holding clamps with bolts & nuts 1257 cable jointing kit straight through ( 3x185 sqmm ) 1258 cable jointing kit straight through ( 3x300sqmm ) 1259 extra prefabricated gi items like clamp, channel, angle with nut & bolt...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32106750 development of distribution infrastructure work for loss reduction at district meerut and baghpat in psvvnl under revamped reforms based and results linked, distribution sector scheme 1 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 2 pcc pole, 8.5 mtr. long 3 bolts and nuts for shackle insulators 4 lt shakle insulator 100x115 mm 5 d straps 6 lt xlpe armoured 3.5x50 sq. mm. cable 7 mid span jointing sleeves ( 50 sq. mm ) 8 insulating piercing connector ( 50 150 sq.mm ) 9 insulation mastic tape ( 2inc x 10 feet ) . 10 supply of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 11 supply of single of phase deep drawn distribution box with clamps and suitable lock and key arrangment 12 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 13 1x16 mm2 xlpe insulated al. cable for energising the street light 14 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 15 gi wire 6 swg 16 lt stay set ( 16 x 1800 mm ) 17 lt stay clamp with nut and bolt 18 stay wire 7 / 10 swg 19 lt stay insulator 20 stone pad ( 300x300x75mm ) 21 lt clamp with nut and bolt for pcc pole 22 angle for vertical arm l50x50x6 ( type a ) 23 angle for vertical arm l50x50x6 ( type b ) 24 top clamp for vertical arm ( type a ) 25 top clamp for vertical arm ( type b ) 26 bottom clamp for vertical arm ( type a ) 27 bottom clamp for vertical arm ( type b ) 28 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 29 pvc 2c x 6 sq.mm. armoured cable for service connection 30 polycarbonated box for single phase consumer 31 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 32 pvc 4c x 16 sq.mm. armoured cable for service connection 33 polycarbonated box for three phase consumer 34 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 35 pcc pole, 8.5 mtr. long 36 stone pad ( 300x300x75mm ) 37 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 38 gi wire 6 swg 39 lt stay set ( 16 x 1800 mm ) 40 lt stay clamp with nut and bolt 41 stay wire 7 / 10 swg 42 lt stay insulator 43 dead end clamps with i hook ( insulated ) 44 suspension clamp with i hook 45 pole clamps with nut and bolt 46 holding clamp for round pole with nut and bolt 47 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 48 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 49 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 50 lt abc of 3x50+1x35+1x16 sq. mm 51 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 52 1x16 mm2 xlpe insulated al. cable for energising the street light 53 end cap for lt ab cable 54 pg clamps 55 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 56 pcc pole, 8.5 mtr. long 57 stone pad ( 300x300x75mm ) 58 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 59 gi wire 6 swg 60 lt stay set ( 16 x 1800 mm ) 61 lt stay clamp with nut and bolt 62 stay wire 7 / 10 swg 63 lt stay insulator 64 dead end clamps with i hook ( insulated ) 65 suspension clamp with i hook 66 pole clamps with nut and bolt 67 holding clamp for round pole with nut and bolt 68 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 69 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 70 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 71 lt abc of 3x95+1x70+1x16 sq. mm 72 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 73 1x16 mm2 xlpe insulated al. cable for energising the street light 74 end cap for lt ab cable 75 pg clamps 76 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 77 pcc pole, 8.5 mtr. long 78 stone pad ( 300x300x75mm ) 79 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 80 gi wire 6 swg 81 lt stay set ( 16 x 1800 mm ) 82 lt stay clamp with nut and bolt 83 stay wire 7 / 10 swg 84 lt stay insulator 85 dead end clamps with i hook ( insulated ) 86 suspension clamp with i hook 87 pole clamps with nut and bolt 88 holding clamp for round pole with nut and bolt 89 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 90 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 91 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 92 lt abc of 3x120+1x95+1x16 sq. mm 93 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 94 1x16 mm2 xlpe insulated al. cable for energising the street light 95 end cap for lt ab cable 96 pg clamps 97 feeder bifurcation ( 11 kv line ) 98 11kv new line on 11 mtr. st pole with acsr dog conductor ( feeder bifurcation 11 kv line ) 99 11 kv polymer disc insulator b&s type 70 kn 100 disc fitting b&s type 70 kn 101 11 kv composite polymer pin insulator with nut and washers 102 11kv smc danger board with clamp, bolts & nuts 103 11kv smc number plate for clamp with n&b 104 11 kv stay set ( 16 x 1800 mm ) 105 11 kv stay clamp with nut and bolt 106 stay wire 7 / 10 swg 107 11 kv stay insulator 108 acsr dog conductor 109 p.g. clamp for acsr dog / raccoon 110 armour rod with ferrule for acsr dog / panther / raccoon helical performed 111 11 mtr. stp 112 13 mtr. stp 113 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 114 aluminium binding wire 6 swg 115 aluminium jointing sleeves 116 g.i. barbed wire 117 gi wire 6 swg 118 gi wire 8 swg 119 gi wire 16 swg 120 eye bolt 121 turn buckle 122 red oxide paint 123 aluminium paint 124 11kv e bracket with n&b 125 11kv `f bracket with n&b 126 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 127 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 128 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 129 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 130 cross arm holding clamp with nuts & bolts 131 v type cross arm for 11kv line, 100x50x6 mm, gi 132 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 133 gi guarding angle iron 75x75x6 mm 3010 mm long 134 stone pad ( 300x300x75mm ) 135 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 136 11 kv polymer disc insulator b&s type 70 kn 137 disc fitting b&s type 70 kn 138 11 kv composite polymer pin insulator with nut and washers 139 11kv smc danger board with clamp, bolts & nuts 140 11kv smc number plate for clamp with n&b 141 11 kv stay set ( 16 x 1800 mm ) 142 11 kv stay clamp with nut and bolt 143 stay wire 7 / 10 swg 144 11 kv stay insulator 145 acsr dog conductor 146 p.g. clamp for acsr dog / raccoon 147 armour rod with ferrule for acsr dog / panther / raccoon helical performed 148 pcc pole, 8.5 mtr. long 149 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 150 aluminium binding wire 6 swg 151 aluminium jointing sleeves 152 g.i. barbed wire 153 gi wire 6 swg 154 gi wire 8 swg 155 gi wire 16 swg 156 eye bolt 157 turn buckle 158 11kv e bracket with n&b 159 11kv `f bracket with n&b 160 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 161 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 162 cross arm holding clamp with nuts & bolts 163 v type cross arm for 11kv line, 100x50x6 mm, gi 164 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 165 gi guarding angle iron 75x75x6 mm 3010 mm long 166 stone pad ( 300x300x75mm ) 167 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 168 11 kv railway crossing 169 11kv 3x185 mm2xlpe cable 170 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 171 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 172 cable route marker 173 g.i. pipe 6 dia . 174 11 mtr. stp 175 stone pad ( 300x300x75mm ) 176 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 177 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 178 11 kv polymer disc insulator b&s type 70 kn 179 disc fitting b&s type 70 kn 180 p.g. clamp for acsr dog / raccoon 181 11kv smc number plate for clamp with n&b 182 11kv smc danger board with clamp, bolts & nuts 183 g.i. barbed wire 184 aluminium binding wire 6 swg 185 aluminium paint 186 red oxide paint 187 11 kvstay set ( 16 x 1800 mm ) 188 11 kv stay clamp with nut and bolt 189 stay wire 7 / 10 swg 190 11 kv stay insulator 191 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 192 gi wire 6 swg 193 nhai / state highway crossing 194 11kv 3x185 mm2xlpe cable 195 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 196 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 197 cable route marker 198 g.i. pipe 6 dia . 199 11 mtr. stp 200 stone pad ( 300x300x75mm ) 201 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 202 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 203 11 kv polymer disc insulator b&s type 70 kn 204 disc fitting b&s type 70 kn 205 p.g. clamp for acsr dog / raccoon 206 11kv smc number plate for clamp with n&b 207 11kv smc danger board with clamp, bolts & nuts 208 g.i. barbed wire 209 aluminium binding wire 6 swg 210 aluminium paint 211 red oxide paint 212 11 kv stay set ( 16 x 1800 mm ) 213 11 kv stay clamp with nut and bolt 214 stay wire 7 / 10 swg 215 11 kv stay insulator 216 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 217 gi wire 6 swg 218 augumentation / reconductoring of 33 kv overhead line with dog conductor 219 acsr dog conductor 220 pcc pole, 9.0 mtr. long 221 11 mtr. stp 222 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 223 gi wire 6 swg 224 33 kv composite polymer pin insulator with nut and washers 225 aluminium paint 226 red oxide paint 227 33kv smc danger board with clamp and n&b 228 33kv smc number plate with clampand n&b 229 stone pad ( 300x300x75mm ) 230 g.i. barbed wire 231 33kv e bracket with n&b 232 33kv f bracket with n&b 233 v type cross arm for 33kv line 100x50x6 mm, gi 234 cross arm holding clamp with nuts & bolts 235 33 kv polymer disc insulator b&s type 70 kn 236 disc fitting b&s type 70 kn 237 33 kv stay set 238 33 kv stay clamp with nut and bolt 239 stay wire 7 / 8 swg 240 33 kv stay insulator 241 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 242 acsr dog conductor 243 11 kv polymer disc insulator b&s type 70 kn 244 disc fitting b&s type 70 kn 245 11 kv composite polymer pin insulator with nut and washers 246 11kv smc danger board with clamp, bolts & nuts 247 11kv smc number plate for clamp with n&b 248 11 kv stay set ( 16 x 1800 mm ) 249 11 kv stay clamp with nut and bolt 250 stay wire 7 / 10 swg 251 11 kv stay insulator 252 p.g. clamp for acsr dog / raccoon 253 armour rod with ferrule for acsr dog / panther / raccoon helical performed 254 pcc pole, 8.5 mtr. long 255 11 mtr. stp 256 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 257 aluminium binding wire 6 swg 258 aluminium jointing sleeves 259 g.i. barbed wire 260 gi wire 6 swg 261 gi wire 8 swg 262 gi wire 16 swg 263 eye bolt 264 turn buckle 265 red oxide paint 266 aluminium paint 267 11kv `f bracket with n&b 268 cross arm holding clamp with nuts & bolts 269 v type cross arm for 11kv line, 100x50x6 mm, gi 270 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 271 stone pad ( 300x300x75mm ) 272 11 kv agriculture feeder segregation & feeder splitting due to overloading 273 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 274 acsr rabbit conductor 275 11kv polymer disc insulator t&c type 45 kn 276 disc fittings t&c type 45 kn 277 11 kv composite polymer pin insulator with nut and washers 278 11kv smc danger board with clamp, bolts & nuts 279 11kv smc number plate for clamp with n&b 280 11 kv stay set ( 16 x 1800 mm ) 281 11 kv stay clamp with nut and bolt 282 stay wire 7 / 10 swg 283 11 kv stay insulator 284 pg clamps 285 armour rod with ferrule for acsr dog / panther / raccoon helical performed 286 pcc pole, 8.5 mtr. long 287 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 288 aluminium binding wire 6 swg 289 aluminium jointing sleeves 290 g.i. barbed wire 291 gi wire 6 swg 292 gi wire 8 swg 293 gi wire 16 swg 294 eye bolt 295 turn buckle 296 11kv e bracket with n&b 297 11kv `f bracket with n&b 298 gi top channel 100x50x2240 mm. 299 clamp with nuts & bolts for 1300 mm long gi channel 300 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 301 gi top channel 100x50x6, 1525 mm long 302 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 303 cross arm holding clamp with nuts & bolts 304 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 305 v type cross arm for 11kv line, 65x65x6 mm, gi angle 306 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 307 stone pad ( 300x300x75mm ) 308 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 309 pcc pole, 8.5 mtr. long 310 stone pad ( 300x300x75mm ) 311 lt clamp with nut and bolt for pcc pole 312 lt shakle insulator 100x115 mm 313 bolts and nuts for shackle insulators 314 acsr rabbit conductor 315 aluminium jointing sleeves 316 aluminium binding wire 6 swg 317 earth wire clamp 318 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 319 gi wire 6 swg 320 lt stay set ( 16 x 1800 mm ) 321 lt stay clamp with nut and bolt 322 stay wire 7 / 10 swg 323 lt stay insulator 324 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 325 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 326 pcc pole, 8.5 mtr. long 327 stone pad ( 300x300x75mm ) 328 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 329 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 330 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 331 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 332 gi channel 125x65x6, 1300mm ( tee off ) 333 clamp with nuts & bolts for 1300 mm long gi channel 334 11kv polymer disc insulator t&c type 45 kn 335 disc fittings t&c type 45 kn 336 11 kv composite polymer pin insulator with nut and washers 337 11kv tpmo complete set 338 11kv do fuse set ( 3 phase ) 339 11kv lightening arrestor 340 g.i. barbed wire 341 11kv smc danger board with clamp, bolts & nuts 342 deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 343 lt stay set ( 16 x 1800 mm ) 344 lt stay clamp with nut and bolt 345 stay wire 7 / 10 swg 346 lt stay insulator 347 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 348 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 349 lt pvc cable3.5x150 / 70sq.mm. 350 acsr weasel conductor 351 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 352 gi wire 6 swg 353 gi strip 25x3 mm 354 gi angle 100x50x2028mm ( fordistribution box ) ) 355 al. crimping lugs 150 sq.mm. 356 al. crimping lugs 70 sq.mm. 357 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 358 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 359 11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 360 pcc pole, 8.5 mtr. long 361 stone pad ( 300x300x75mm ) 362 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 363 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 364 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 365 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 366 gi channel 125x65x6, 1300mm ( tee off ) 367 clamp with nuts & bolts for 1300 mm long gi channel 368 11kv polymer disc insulator t&c type 45 kn 369 disc fittings t&c type 45 kn 370 11 kv composite polymer pin insulator with nut and washers 371 11kv tpmo complete set 372 11kv do fuse set ( 3 phase ) 373 11kv lightening arrestor 374 g.i. barbed wire 375 11kv smc danger board with clamp, bolts & nuts 376 deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 377 lt stay set ( 16 x 1800 mm ) 378 lt stay clamp with nut and bolt 379 stay wire 7 / 10 swg 380 lt stay insulator 381 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 382 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 383 lt pvc cable3.5x70 / 35sq.mm. 384 acsr weasel conductor 385 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 386 gi wire 6 swg 387 gi strip 25x3 mm 388 gi angle 100x50x2028mm ( fordistribution box ) ) 389 al. crimping lugs 70 sq.mm. 390 al. crimping lugs 35 sq.mm. 391 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 392 construction of new 25 kva, 11 / 0.433kv distribution transformer s / s 393 11 / 0.44 kv 25 kva transformer ( four star rating, level ii ) 394 pcc pole, 8.5 mtr. long 395 stone pad ( 300x300x75mm ) 396 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 397 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 398 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 399 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 400 gi channel 125x65x6, 1300mm ( tee off ) 401 clamp with nuts & bolts for 1300 mm long gi channel 402 11kv polymer disc insulator t&c type 45 kn 403 disc fittings t&c type 45 kn 404 11 kv composite polymer pin insulator with nut and washers 405 11kv tpmo complete set 406 11kv do fuse set ( 3 phase ) 407 11kv lightening arrestor 408 g.i. barbed wire 409 11kv smc danger board with clamp, bolts & nuts 410 deep drawn distribution boxas per technical specifications for 3 ph 25 kva dtr 411 lt stay set ( 16 x 1800 mm ) 412 lt stay clamp with nut and bolt 413 stay wire 7 / 10 swg 414 lt stay insulator 415 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 416 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 417 lt xlpe insulated unarmoured 4x25 sq. mm.cable 418 acsr weasel conductor 419 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 420 gi wire 6 swg 421 gi strip 25x3 mm 422 gi angle 100x50x2028mm ( fordistribution box ) ) 423 al. crimping lugs 25 sq.mm. 424 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 425 installation of 11 kv outgoing vcb for feeder segreration 426 11kv outgoing ctr 400 / 200 / 5a 350 mva 427 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 428 11kv 3x185 mm2xlpe cable 429 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 430 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 431 11 mtr. stp 432 gi top channel 100x50x2240 mm. 433 stone pad ( 300x300x75mm ) 434 11 kv polymer disc insulator b&s type 70 kn 435 disc fitting b&s type 70 kn 436 11 kv composite polymer pin insulator with nut and washers 437 p.g. clamp for acsr dog / raccoon 438 11kv e bracket with n&b 439 11kv smc number plate for clamp with n&b 440 11kv smc danger board with clamp, bolts & nuts 441 gi channel 125x65x2028 mm long ( dropper for fuse set ) 442 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 443 11kv tpmo complete set 444 11kv do fuse set ( 3 phase ) 445 11kv lightening arrestor 446 g.i. barbed wire 447 aluminium binding wire 6 swg 448 aluminium paint 449 red oxide paint 450 11 kv stay set ( 16 x 1800 mm ) 451 11 kv stay clamp with nut and bolt 452 stay wire 7 / 10 swg 453 11 kv stay insulator 454 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 455 gi strip 50x6 mm 456 gi wire 6 swg 457 g.i. pipe 6 dia . 458 11 kv railway crossing 459 11kv 3x185 mm2xlpe cable 460 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 461 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 462 cable route marker 463 g.i. pipe 6 dia . 464 11 mtr. stp 465 stone pad ( 300x300x75mm ) 466 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 467 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 468 11 kv polymer disc insulator b&s type 70 kn 469 disc fitting b&s type 70 kn 470 p.g. clamp for acsr dog / raccoon 471 11kv smc number plate for clamp with n&b 472 11kv smc danger board with clamp, bolts & nuts 473 g.i. barbed wire 474 aluminium binding wire 6 swg 475 aluminium paint 476 red oxide paint 477 11 kvstay set ( 16 x 1800 mm ) 478 11 kv stay clamp with nut and bolt 479 stay wire 7 / 10 swg 480 11 kv stay insulator 481 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 482 gi wire 6 swg 483 nhai / state highway crossing 484 11kv 3x185 mm2xlpe cable 485 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 486 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 487 cable route marker 488 g.i. pipe 6 dia . 489 11 mtr. stp 490 stone pad ( 300x300x75mm ) 491 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 492 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 493 11 kv polymer disc insulator b&s type 70 kn 494 disc fitting b&s type 70 kn 495 p.g. clamp for acsr dog / raccoon 496 11kv smc number plate for clamp with n&b 497 11kv smc danger board with clamp, bolts & nuts 498 g.i. barbed wire 499 aluminium binding wire 6 swg 500 aluminium paint 501 red oxide paint 502 11 kv stay set ( 16 x 1800 mm ) 503 11 kv stay clamp with nut and bolt 504 stay wire 7 / 10 swg 505 11 kv stay insulator 506 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 507 gi wire 6 swg 508 requirement of extra ab cable for new additional ckt at dts 509 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 510 pcc pole, 8.5 mtr. long 511 11 mtr. stp 512 stone pad ( 300x300x75mm ) 513 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 514 gi wire 6 swg 515 lt stay set ( 16 x 1800 mm ) 516 lt stay clamp with nut and bolt 517 stay wire 7 / 10 swg 518 lt stay insulator 519 dead end clamps with i hook ( insulated ) 520 suspension clamp with i hook 521 pole clamps with nut and bolt 522 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 523 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 524 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 525 lt abc of 3x50+1x35+1x16 sq. mm 526 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 527 end cap for lt ab cable 528 pg clamps 529 1x16 mm2 xlpe insulated al. cable for energising the street light 530 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 531 pcc pole, 8.5 mtr. long 532 11 mtr. stp 533 stone pad ( 300x300x75mm ) 534 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 535 gi wire 6 swg 536 lt stay set ( 16 x 1800 mm ) 537 lt stay clamp with nut and bolt 538 stay wire 7 / 10 swg 539 lt stay insulator 540 dead end clamps with i hook ( insulated ) 541 suspension clamp with i hook 542 pole clamps with nut and bolt 543 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 544 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 545 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 546 lt abc of 3x95+1x70+1x16 sq. mm 547 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 548 end cap for lt ab cable 549 pg clamps 550 1x16 mm2 xlpe insulated al. cable for energising the street light 551 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 552 pcc pole, 8.5 mtr. long 553 11 mtr. stp 554 stone pad ( 300x300x75mm ) 555 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 556 gi wire 6 swg 557 lt stay set ( 16 x 1800 mm ) 558 lt stay clamp with nut and bolt 559 stay wire 7 / 10 swg 560 lt stay insulator 561 dead end clamps with i hook ( insulated ) 562 suspension clamp with i hook 563 pole clamps with nut and bolt 564 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 565 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 566 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 567 lt abc of 3x120+1x95+1x16 sq. mm 568 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 569 end cap for lt ab cable 570 pg clamps 571 1x16 mm2 xlpe insulated al. cable for energising the street light 572 additional items that may be required for completion of work 573 3x120 sq. mm 11 kv ab cable 574 11kv polymer disc insulator with fitting for 11 kvabc 575 11kv polymer disc insulators with i hook 576 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 577 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 578 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 579 33kv 3x300 mm2xlpe cable 580 lt xlpe insulated unarmoured 1x50 sq. mm. cable 581 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 582 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 583 loop guard complete, 3 phase 584 spacers lt pvc 585 mid span jointing sleeves ( 95 sq. mm ) 586 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 587 supply of on / off switch for street light connections 588 height raising channel 100x50, 2240 mm long 589 back clamp for height raising channel holding clamps with bolts & nuts 590 cable jointing kit straight through ( 3x185 sqmm ) 591 cable jointing kit straight through ( 3x300sqmm ) 592 extra prefabricated gi items like clamp, channel, angle with nut & bolt 593 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 594 erection of pcc pole, 8.5 mtr. long 595 fixing of bolts and nuts for shackle insulators 596 fixing of lt shakle insulator 100x115 mm 597 fixing of d straps 598 stringing of lt xlpe armoured 3.5x50 sq. mm. cable 599 fixing of mid span jointing sleeves ( 120 sq. mm ) 600 fixing of insulating piercing connector ( 50 150 sq.mm ) 601 fixing of insulation mastic tape ( 2inc x 10 feet ) . 602 fixing of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 603 fixing of single phase deep drawn distribution box with clamps and suitable lock and key arrangment 604 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 605 1x16 mm2 xlpe insulated al. cable for energising the street light 606 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 607 gi wire 6 swg 608 erection of lt stay set ( 16 x 1800 mm ) 609 fixing of lt stay clamp with nut and bolt 610 erection of stay wire 7 / 10 swg 611 fixing of lt stay insulator 612 concreting of stay set ( 16x 1800 mm ) 613 stone pad ( 300x300x75mm ) 614 fixing of lt clamp with nut and bolt for pcc pole 615 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 616 concreting of pole / support ( 0.268 cu.m. ) 617 fixing of angle for vertical arm l50x50x6 ( type a ) 618 fixing of angle for vertical arm l50x50x6 ( type b ) 619 fixing of top clamp for vertical arm ( type a ) 620 fixing of top clamp for vertical arm ( type b ) 621 fixing of bottom clamp for vertical arm ( type a ) 622 fixing of bottom clamp for vertical arm ( type b ) 623 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 624 stringing of pvc 2c x 6 sq.mm. armoured cable for service connection 625 dismanting of old line service cable and connection of new armoured cable 626 fixing of polycarbonated box for single phase consumer 627 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 628 stringing of pvc 4c x 16 sq.mm. armoured cable for service connection 629 dismanting of old line service cable and connection of new armoured cable 630 fixing of polycarbonated box for three phase consumer 631 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 632 erection of pcc pole, 8.5 mtr. long 633 stone pad ( 300x300x75mm ) 634 concreting of pole / support ( 0.268 cu.m. ) 635 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 636 gi wire 6 swg 637 erection of lt stay set ( 16 x 1800 mm ) 638 fixing of lt stay clamp with nut and bolt 639 erection of stay wire 7 / 10 swg 640 fixing of lt stay insulator 641 concreting of stay set ( 16x 1800 mm ) 642 fixing of dead end clamps with i hook ( insulated ) 643 fixing of suspension clamp with i hook 644 fixing of pole clamps with nut and bolt 645 fixing of holding clamp for round pole with nut and bolt 646 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 647 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 648 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 649 stringing of lt abc of 3x50+1x35+1x16 sq. mm 650 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 651 1x16 mm2 xlpe insulated al. cable for energising the street light 652 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 653 fixing of end cap for lt ab cable 654 fixing of pg clamps 655 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 656 erection of pcc pole, 8.5 mtr. long 657 stone pad ( 300x300x75mm ) 658 concreting of pole / support ( 0.268 cu.m. ) 659 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 660 gi wire 6 swg 661 erection of lt stay set ( 16 x 1800 mm ) 662 fixing of lt stay clamp with nut and bolt 663 erection of stay wire 7 / 10 swg 664 fixing of lt stay insulator 665 concreting of stay set ( 16x 1800 mm ) 666 dead end clamps with i hook ( insulated ) 667 fixing of suspension clamp with i hook 668 fixing of pole clamps with nut and bolt 669 holding clamp for round pole with nut and bolt 670 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 671 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 672 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 673 stringing of lt abc of 3x95+1x70+1x16 sq. mm 674 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 675 1x16 mm2 xlpe insulated al. cable for energising the street light 676 end cap for lt ab cable 677 fixing of pg clamps 678 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 679 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 680 erection of pcc pole, 8.5 mtr. long 681 stone pad ( 300x300x75mm ) 682 concreting of pole / support ( 0.268 cu.m. ) 683 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 684 gi wire 6 swg 685 erection of lt stay set ( 16 x 1800 mm ) 686 fixing of lt stay clamp with nut and bolt 687 erection of stay wire 7 / 10 swg 688 fixing of lt stay insulator 689 concreting of stay set ( 16x 1800 mm ) 690 dead end clamps with i hook ( insulated ) 691 fixing of suspension clamp with i hook 692 fixing of pole clamps with nut and bolt 693 holding clamp for round pole with nut and bolt 694 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 695 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 696 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 697 stringing of lt abc of 3x120+1x95+1x16 sq. mm 698 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 699 1x16 mm2 xlpe insulated al. cable for energising the street light 700 end cap for lt ab cable 701 fixing of pg clamps 702 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 703 feeder bifurcation ( 11 kv line ) 704 11kv new line on 11 mtr. st pole with acsr dog conductor 705 erection of 11 kv polymer disc insulator b&s type 70 kn 706 erection of disc fitting b&s type 70 kn 707 erection of 11 kv composite polymer pin insulator with nut and washers 708 fixing of 11kv smc danger board with clamp, bolts & nuts 709 fixing of 11kv smc number plate for clamp with n&b 710 erection of 11 kv stay set ( 16 x 1800 mm ) 711 fixing of 11 kv stay clamp with nut and bolt 712 erection of stay wire 7 / 10 swg 713 fixing of 11 kv stay insulator 714 concreting of stay set ( 16x 1800 mm ) 715 stringing of acsr dog conductor 716 fixing of p.g. clamp for acsr dog / raccoon 717 armour rod with ferrule for acsr dog / panther / raccoon helical performed 718 erection of 11 mtr. stp 719 erection of 13 mtr. stp 720 concreting of pole / support ( 0.44 cu.m. ) 721 concreting of pole ( 0.64 cu.m. ) 722 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 723 aluminium binding wire 6 swg 724 aluminium jointing sleeves 725 g.i. barbed wire 726 gi wire 6 swg 727 gi wire 8 swg 728 gi wire 16 swg 729 eye bolt 730 turn buckle 731 painting of st pole with red oxide paint 732 painting of st pole with aluminium paint 733 erection of 11kv e bracket with n&b 734 erection of 11kv `f bracket with n&b 735 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 736 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 737 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 738 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 739 cross arm holding clamp with nuts & bolts 740 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 741 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 742 gi guarding angle iron 75x75x6 mm 3010 mm long 743 tree cutting compensation 744 stone pad ( 300x300x75mm ) 745 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 746 erection of 11 kv polymer disc insulator b&s type 70 kn 747 erection of disc fitting b&s type 70 kn 748 erection of 11 kv composite polymer pin insulator with nut and washers 749 fixing of 11kv smc danger board with clamp, bolts & nuts 750 fixing of 11kv smc number plate for clamp with n&b 751 erection of 11 kv stay set ( 16 x 1800 mm ) 752 fixing of 11 kv stay clamp with nut and bolt 753 erection of stay wire 7 / 10 swg 754 fixing of 11 kv stay insulator 755 concreting of stay set ( 16x 1800 mm ) 756 stringing of acsr dog conductor 757 fixing of p.g. clamp for acsr dog / raccoon 758 armour rod with ferrule for acsr dog / panther / raccoon helical performed 759 erection of pcc pole, 8.5 mtr. long 760 concreting of pole / support ( 0.268 cu.m. ) 761 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 762 aluminium binding wire 6 swg 763 aluminium jointing sleeves 764 g.i. barbed wire 765 gi wire 6 swg 766 gi wire 8 swg 767 gi wire 16 swg 768 eye bolt 769 turn buckle 770 erection of 11kv e bracket with n&b 771 erection of 11kv `f bracket with n&b 772 gi top channel 125x65mm, 3200 mm with clamp, bolts, nuts and washers 773 gi angle 65x65x6mm, 4300 mm long bracing with 4 clamps, bolts, nuts and washers 774 cross arm holding clamp with nuts & bolts 775 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 776 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 777 gi guarding angle iron 75x75x6 mm 3010 mm long 778 tree cutting compensation 779 stone pad ( 300x300x75mm ) 780 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 781 11 kv railway crossing 782 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 783 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 784 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 785 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 786 cable route marker 787 g.i. pipe 6 dia . 788 erection of 11 mtr. stp 789 stone pad ( 300x300x75mm ) 790 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 791 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 792 erection of 11 kv polymer disc insulator b&s type 70 kn 793 erection of disc fitting b&s type 70 kn 794 fixing of p.g. clamp for acsr dog / raccoon 795 fixing of 11kv smc number plate for clamp with n&b 796 fixing of 11kv smc danger board with clamp, bolts & nuts 797 g.i. barbed wire 798 aluminium binding wire 6 swg 799 painting of st pole with aluminium paint 800 painting of st pole with red oxide paint 801 erection of 11 kvstay set ( 16 x 1800 mm ) 802 fixing of 11 kv stay clamp with nut and bolt 803 erection of stay wire 7 / 10 swg 804 fixing of 11 kv stay insulator 805 concreting of stay set ( 16x 1800 mm ) 806 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 807 gi wire 6 swg 808 concreting of pole / support ( 0.44 cu.m. ) 809 railway crossing documentation, land and approval fee etc. 810 nhai / state highway crossing 811 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 812 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 813 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 814 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 815 cable route marker 816 g.i. pipe 6 dia . 817 erection of 11 mtr. stp 818 stone pad ( 300x300x75mm ) 819 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 820 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 821 erection of 11 kv polymer disc insulator b&s type 70 kn 822 disc fitting b&s type 70 kn 823 fixing of p.g. clamp for acsr dog / raccoon 824 fixing of 11kv smc number plate for clamp with n&b 825 fixing of 11kv smc danger board with clamp, bolts & nuts 826 g.i. barbed wire 827 aluminium binding wire 6 swg 828 painting of st pole with aluminium paint 829 painting of st pole with red oxide paint 830 erection of 11 kv stay set ( 16 x 1800 mm ) 831 fixing of 11 kv stay clamp with nut and bolt 832 erection of stay wire 7 / 10 swg 833 fixing of 11 kv stay insulator 834 concreting of stay set ( 16x 1800 mm ) 835 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 836 gi wire 6 swg 837 concreting of pole / support ( 0.44 cu.m. ) 838 nhai / state highway crossing documentation, land charges and approval fee etc. 839 road restoration charges 840 augumentation / reconductoring of 33 kv overhead line with dog conductor 841 stringing of acsr dog conductor 842 erection of pcc pole, 9.0 mtr. long 843 erection of 11 mtr. stp 844 concreting of pole / support ( 0.286 cu.m. ) 845 concreting of pole / support ( 0.44 cu.m. ) 846 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 847 gi wire 6 swg 848 erection of 33 kv composite polymer pin insulator with nut and washers 849 painting of st pole with aluminium paint 850 painting of st pole with red oxide paint 851 fixing of 33kv smc danger board with clamp and n&b 852 fixing of 33kv smc number plate with clampand n&b 853 stone pad ( 300x300x75mm ) 854 g.i. barbed wire 855 erection of 33kv e bracket with n&b 856 erection of 33kv f bracket with n&b 857 erection of v type cross arm for 33kv line 100x50x6 mm, gi 858 cross arm holding clamp with nuts & bolts 859 erection of 33 kv polymer disc insulator b&s type 70 kn 860 disc fitting b&s type 70 kn 861 erection of 33 kv stay set 862 fixing of 33 kv stay clamp with nut and bolt 863 erection of stay wire 7 / 8 swg 864 fixing of 33 kv stay insulator 865 concreting of 33 kv stay set 866 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 867 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 868 stringing of acsr dog conductor 869 erection of 11 kv polymer disc insulator b&s type 70 kn 870 disc fitting b&s type 70 kn 871 erection of 11 kv composite polymer pin insulator with nut and washers 872 fixing of 11kv smc danger board with clamp, bolts & nuts 873 fixing of 11kv smc number plate for clamp with n&b 874 erection of 11 kv stay set ( 16 x 1800 mm ) 875 fixing of 11 kv stay clamp with nut and bolt 876 erection of stay wire 7 / 10 swg 877 fixing of 11 kv stay insulator 878 concreting of stay set ( 16x 1800 mm ) 879 fixing of p.g. clamp for acsr dog / raccoon 880 armour rod with ferrule for acsr dog / panther / raccoon helical performed 881 erection of pcc pole, 8.5 mtr. long 882 erection of 11 mtr. stp 883 concreting of pole / support ( 0.268 cu.m. ) 884 concreting of pole / support ( 0.44 cu.m. ) 885 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 886 aluminium binding wire 6 swg 887 aluminium jointing sleeves 888 g.i. barbed wire 889 gi wire 6 swg 890 gi wire 8 swg 891 gi wire 16 swg 892 eye bolt 893 turn buckle 894 painting of st pole with red oxide paint 895 painting of st pole with aluminium paint 896 erection of 11kv `f bracket with n&b 897 cross arm holding clamp with nuts & bolts 898 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 899 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 900 stone pad ( 300x300x75mm ) 901 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 902 11 kv agriculture feeder segregation & feeder splitting due to overloading 903 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 904 stringing of acsr rabbit conductor 905 erection of 11kv polymer disc insulator t&c type 45 kn 906 disc fittings t&c type 45 kn 907 erection of 11 kv composite polymer pin insulator with nut and washers 908 fixing of 11kv smc danger board with clamp, bolts & nuts 909 fixing of 11kv smc number plate for clamp with n&b 910 erection of 11 kv stay set ( 16 x 1800 mm ) 911 fixing of 11 kv stay clamp with nut and bolt 912 erection of stay wire 7 / 10 swg 913 fixing of 11 kv stay insulator 914 concreting of stay set ( 16x 1800 mm ) 915 fixing of pg clamps 916 armour rod with ferrule for acsr dog / panther / raccoon helical performed 917 erection of pcc pole, 8.5 mtr. long 918 concreting of pole / support ( 0.268 cu.m. ) 919 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 920 aluminium binding wire 6 swg 921 aluminium jointing sleeves 922 g.i. barbed wire 923 gi wire 6 swg 924 gi wire 8 swg 925 gi wire 16 swg 926 eye bolt 927 turn buckle 928 erection of 11kv e bracket with n&b 929 erection of 11kv `f bracket with n&b 930 gi top channel 100x50x2240 mm. 931 clamp with nuts & bolts for 1300 mm long gi channel 932 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 933 gi top channel 100x50x6, 1525 mm long 934 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 935 cross arm holding clamp with nuts & bolts 936 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 937 erection of v type cross arm for 11kv line, 65x65x6 mm, gi angle 938 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 939 tree cutting compensation 940 stone pad ( 300x300x75mm ) 941 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 942 erection of pcc pole, 8.5 mtr. long 943 stone pad ( 300x300x75mm ) 944 lt clamp with nut and bolt for pcc pole 945 lt shakle insulator 100x115 mm 946 bolts and nuts for shackle insulators 947 concreting of pole / support ( 0.268 cu.m. ) 948 stringing of acsr rabbit conductor 949 aluminium jointing sleeves 950 aluminium binding wire 6 swg 951 earth wire clamp 952 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 953 gi wire 6 swg 954 erection of lt stay set ( 16 x 1800 mm ) 955 fixing of lt stay clamp with nut and bolt 956 erection of stay wire 7 / 10 swg 957 fixing of lt stay insulator 958 concreting of stay set ( 16x 1800 mm ) 959 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 960 installation of 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 961 erection of pcc pole, 8.5 mtr. long 962 stone pad ( 300x300x75mm ) 963 concreting of pole / support ( 0.268 cu.m. ) 964 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 965 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 966 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 967 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 968 gi channel 125x65x6, 1300mm ( tee off ) 969 clamp with nuts & bolts for 1300 mm long gi channel 970 erection of 11kv polymer disc insulator t&c type 45 kn 971 disc fittings t&c type 45 kn 972 erection of 11 kv composite polymer pin insulator with nut and washers 973 erection of 11kv tpmo complete set 974 erection of 11kv do fuse set ( 3 phase ) 975 erection of 11kv lightening arrestor 976 g.i. barbed wire 977 fixing of 11kv smc danger board with clamp, bolts & nuts 978 fixing of deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 979 erection of lt stay set ( 16 x 1800 mm ) 980 fixing of lt stay clamp with nut and bolt 981 erection of stay wire 7 / 10 swg 982 fixing of lt stay insulator 983 concreting of stay set ( 16x 1800 mm ) 984 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 985 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 986 lt pvc cable3.5x150 / 70sq.mm. 987 acsr weasel conductor 988 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 989 gi wire 6 swg 990 gi strip 25x3 mm 991 gi angle 100x50x2028mm ( fordistribution box ) ) 992 al. crimping lugs 150 sq.mm. 993 al. crimping lugs 70 sq.mm. 994 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 995 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 996 installation of11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 997 erection of pcc pole, 8.5 mtr. long 998 stone pad ( 300x300x75mm ) 999 concreting of pole / support ( 0.268 cu.m. ) 1000 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1001 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 1002 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1003 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 1004 gi channel 125x65x6, 1300mm ( tee off ) 1005 clamp with nuts & bolts for 1300 mm long gi channel 1006 erection of 11kv polymer disc insulator t&c type 45 kn 1007 disc fittings t&c type 45 kn 1008 erection of 11 kv composite polymer pin insulator with nut and washers 1009 erection of 11kv tpmo complete set 1010 erection of 11kv do fuse set ( 3 phase ) 1011 erection of 11kv lightening arrestor 1012 g.i. barbed wire 1013 fixing of 11kv smc danger board with clamp, bolts & nuts 1014 fixing of deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 1015 erection of lt stay set ( 16 x 1800 mm ) 1016 fixing of lt stay clamp with nut and bolt 1017 erection of stay wire 7 / 10 swg 1018 fixing of lt stay insulator 1019 concreting of stay set ( 16x 1800 mm ) 1020 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 1021 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 1022 lt pvc cable3.5x70 / 35sq.mm. 1023 acsr weasel conductor 1024 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1025 gi wire 6 swg 1026 gi strip 25x3 mm 1027 gi angle 100x50x2028mm ( fordistribution box ) ) 1028 al. crimping lugs 70 sq.mm. 1029 al. crimping lugs 35 sq.mm. 1030 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 1031 construction of new 25 kva, 11 / 0.433kv distribution transformer s / s 1032 installation of11 / 0.44 kv 25 kva transformer ( four star rating, level ii ) 1033 erection of pcc pole, 8.5 mtr. long 1034 stone pad ( 300x300x75mm ) 1035 concreting of pole / support ( 0.268 cu.m. ) 1036 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1037 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 1038 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1039 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 1040 gi channel 125x65x6, 1300mm ( tee off ) 1041 clamp with nuts & bolts for 1300 mm long gi channel 1042 erection of 11kv polymer disc insulator t&c type 45 kn 1043 disc fittings t&c type 45 kn 1044 erection of 11 kv composite polymer pin insulator with nut and washers 1045 erection of 11kv tpmo complete set 1046 erection of 11kv do fuse set ( 3 phase ) 1047 erection of 11kv lightening arrestor 1048 g.i. barbed wire 1049 fixing of 11kv smc danger board with clamp, bolts & nuts 1050 fixing of deep drawn distribution boxas per technical specifications for 3 ph 25 kva dtr 1051 erection of lt stay set ( 16 x 1800 mm ) 1052 fixing of lt stay clamp with nut and bolt 1053 erection of stay wire 7 / 10 swg 1054 fixing of lt stay insulator 1055 concreting of stay set ( 16x 1800 mm ) 1056 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 1057 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 1058 lt xlpe insulated unarmoured 4x25 sq. mm.cable 1059 acsr weasel conductor 1060 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1061 gi wire 6 swg 1062 gi strip 25x3 mm 1063 gi angle 100x50x2028mm ( fordistribution box ) ) 1064 al. crimping lugs 25 sq.mm. 1065 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 1066 installation of 11 kv outgoing vcb for feeder segreration 1067 installation of 11kv outgoing ctr 400 / 200 / 5a 350 mva 1068 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 1069 11kv 3x185 mm2xlpe cable 1070 laying of 11 kv cable including cost of sand & bricks 1071 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1072 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1073 erection of 11 mtr. stp 1074 gi top channel 100x50x2240 mm. 1075 stone pad ( 300x300x75mm ) 1076 erection of 11 kv polymer disc insulator b&s type 70 kn 1077 disc fitting b&s type 70 kn 1078 erection of 11 kv composite polymer pin insulator with nut and washers 1079 fixing of p.g. clamp for acsr dog / raccoon 1080 erection of 11kv e bracket with n&b 1081 fixing of 11kv smc number plate for clamp with n&b 1082 fixing of 11kv smc danger board with clamp, bolts & nuts 1083 gi channel 125x65x2028 mm long ( dropper for fuse set ) 1084 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1085 erection of 11kv tpmo complete set 1086 erection of 11kv do fuse set ( 3 phase ) 1087 erection of 11kv lightening arrestor 1088 g.i. barbed wire 1089 aluminium binding wire 6 swg 1090 painting of st pole with aluminium paint 1091 painting of st pole with red oxide paint 1092 erection of 11 kv stay set ( 16 x 1800 mm ) 1093 fixing of 11 kv stay clamp with nut and bolt 1094 erection of stay wire 7 / 10 swg 1095 fixing of 11 kv stay insulator 1096 concreting of stay set ( 16x 1800 mm ) 1097 concreting of pole / support ( 0.44 cu.m. ) 1098 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1099 gi strip 50x6 mm 1100 gi wire 6 swg 1101 g.i. pipe 6 dia . 1102 control room extension 1103 extension of existing substationcontrol room building. ( as per annexure attached in tender documents. ) 1104 11 kv railway crossing 1105 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1106 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1107 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1108 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1109 cable route marker 1110 g.i. pipe 6 dia . 1111 erection of 11 mtr. stp 1112 stone pad ( 300x300x75mm ) 1113 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1114 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1115 erection of 11 kv polymer disc insulator b&s type 70 kn 1116 disc fitting b&s type 70 kn 1117 fixing of p.g. clamp for acsr dog / raccoon 1118 fixing of 11kv smc number plate for clamp with n&b 1119 fixing of 11kv smc danger board with clamp, bolts & nuts 1120 g.i. barbed wire 1121 aluminium binding wire 6 swg 1122 painting of st pole with aluminium paint 1123 painting of st pole with red oxide paint 1124 erection of 11 kvstay set ( 16 x 1800 mm ) 1125 fixing of 11 kv stay clamp with nut and bolt 1126 erection of stay wire 7 / 10 swg 1127 fixing of 11 kv stay insulator 1128 concreting of stay set ( 16x 1800 mm ) 1129 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1130 gi wire 6 swg 1131 concreting of pole / support ( 0.44 cu.m. ) 1132 railway crossing documentation, land and approval fee etc. 1133 nhai / state highway crossing 1134 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1135 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1136 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1137 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1138 cable route marker 1139 g.i. pipe 6 dia . 1140 erection of 11 mtr. stp 1141 stone pad ( 300x300x75mm ) 1142 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1143 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1144 erection of 11 kv polymer disc insulator b&s type 70 kn 1145 disc fitting b&s type 70 kn 1146 fixing of p.g. clamp for acsr dog / raccoon 1147 fixing of 11kv smc number plate for clamp with n&b 1148 fixing of 11kv smc danger board with clamp, bolts & nuts 1149 g.i. barbed wire 1150 aluminium binding wire 6 swg 1151 painting of st pole with aluminium paint 1152 painting of st pole with red oxide paint 1153 erection of 11 kv stay set ( 16 x 1800 mm ) 1154 fixing of 11 kv stay clamp with nut and bolt 1155 erection of stay wire 7 / 10 swg 1156 fixing of 11 kv stay insulator 1157 concreting of stay set ( 16x 1800 mm ) 1158 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1159 gi wire 6 swg 1160 concreting of pole / support ( 0.44 cu.m. ) 1161 nhai / state highway crossing documentation, land charges and approval fee etc. 1162 road restoration charges 1163 requirement of extra ab cable for new additional ckt at dts 1164 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 1165 erection of pcc pole, 8.5 mtr. long 1166 erection of 11 mtr. stp 1167 stone pad ( 300x300x75mm ) 1168 concreting of pole / support ( 0.268 cu.m. ) 1169 concreting of pole / support ( 0.44 cu.m. ) 1170 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1171 gi wire 6 swg 1172 erection of lt stay set ( 16 x 1800 mm ) 1173 fixing of lt stay clamp with nut and bolt 1174 erection of stay wire 7 / 10 swg 1175 fixing of lt stay insulator 1176 concreting of stay set ( 16x 1800 mm ) 1177 dead end clamps with i hook ( insulated ) 1178 fixing of suspension clamp with i hook 1179 fixing of pole clamps with nut and bolt 1180 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1181 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1182 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1183 stringing of lt abc of 3x50+1x35+1x16 sq. mm 1184 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1185 end cap for lt ab cable 1186 fixing of pg clamps 1187 1x16 mm2 xlpe insulated al. cable for energising the street light 1188 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 1189 erection of pcc pole, 8.5 mtr. long 1190 erection of 11 mtr. stp 1191 stone pad ( 300x300x75mm ) 1192 concreting of pole / support ( 0.268 cu.m. ) 1193 concreting of pole / support ( 0.44 cu.m. ) 1194 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1195 gi wire 6 swg 1196 erection of lt stay set ( 16 x 1800 mm ) 1197 fixing of lt stay clamp with nut and bolt 1198 erection of stay wire 7 / 10 swg 1199 fixing of lt stay insulator 1200 concreting of stay set ( 16x 1800 mm ) 1201 dead end clamps with i hook ( insulated ) 1202 fixing of suspension clamp with i hook 1203 fixing of pole clamps with nut and bolt 1204 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1205 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1206 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1207 stringing of lt abc of 3x95+1x70+1x16 sq. mm 1208 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1209 end cap for lt ab cable 1210 fixing of pg clamps 1211 1x16 mm2 xlpe insulated al. cable for energising the street light 1212 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 1213 erection of pcc pole, 8.5 mtr. long 1214 erection of 11 mtr. stp 1215 stone pad ( 300x300x75mm ) 1216 concreting of pole / support ( 0.268 cu.m. ) 1217 concreting of pole / support ( 0.44 cu.m. ) 1218 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1219 gi wire 6 swg 1220 erection of lt stay set ( 16 x 1800 mm ) 1221 fixing of lt stay clamp with nut and bolt 1222 erection of stay wire 7 / 10 swg 1223 fixing of lt stay insulator 1224 concreting of stay set ( 16x 1800 mm ) 1225 dead end clamps with i hook ( insulated ) 1226 fixing of suspension clamp with i hook 1227 fixing of pole clamps with nut and bolt 1228 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1229 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1230 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1231 stringing of lt abc of 3x120+1x95+1x16 sq. mm 1232 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1233 end cap for lt ab cable 1234 fixing of pg clamps 1235 1x16 mm2 xlpe insulated al. cable for energising the street light 1236 additional items that may be required for completion of work 1237 3x120 sq. mm 11 kv ab cable 1238 11kv polymer disc insulator with fitting for 11 kvabc 1239 11kv polymer disc insulators with i hook 1240 erection & concreting of extra stud pole complete with clamps, 1241 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 1242 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 1243 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 1244 lt xlpe insulated unarmoured 1x50 sq. mm. cable 1245 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 1246 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 1247 laying of 3x300 sq. mm. 33 kv xlpe insulated cable underground in hdpe pipe or trenches ( for railway / road crossing ) 1248 drilling & laying of ht underground cable using hdd method without using hdpe pipe 1249 loop guard complete, 3 phase 1250 spacers lt pvc 1251 mid span jointing sleeves ( 95 sq. mm ) 1252 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 1253 fixing of on / off switch for street light connections 1254 mounting of cable on dp structure ( including loop and riser ) 1255 height raising channel 100x50, 2240 mm long 1256 back clamp for height raising channel holding clamps with bolts & nuts 1257 cable jointing kit straight through ( 3x185 sqmm ) 1258 cable jointing kit straight through ( 3x300sqmm ) 1259 extra prefabricated gi items like clamp, channel, angle with nut & bolt...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32106702 development of distribution infrastructure for loss reduction works atdistrict bulandshahr and hapur of uttar pradesh under revamped reforms based and results linked, distribution sector scheme 1 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 2 pcc pole, 8.5 mtr. long 3 bolts and nuts for shackle insulators 4 lt shakle insulator 100x115 mm 5 d straps 6 lt xlpe armoured 3.5x50 sq. mm. cable 7 mid span jointing sleeves ( 50 sq. mm ) 8 insulating piercing connector ( 50 150 sq.mm ) 9 insulation mastic tape ( 2inc x 10 feet ) . 10 supply of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 11 supply of single of phase deep drawn distribution box with clamps and suitable lock and key arrangment 12 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 13 1x16 mm2 xlpe insulated al. cable for energising the street light 14 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 15 gi wire 6 swg 16 lt stay set ( 16 x 1800 mm ) 17 lt stay clamp with nut and bolt 18 stay wire 7 / 10 swg 19 lt stay insulator 20 stone pad ( 300x300x75mm ) 21 lt clamp with nut and bolt for pcc pole 22 angle for vertical arm l50x50x6 ( type a ) 23 angle for vertical arm l50x50x6 ( type b ) 24 top clamp for vertical arm ( type a ) 25 top clamp for vertical arm ( type b ) 26 bottom clamp for vertical arm ( type a ) 27 bottom clamp for vertical arm ( type b ) 28 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 29 pvc 2c x 6 sq.mm. armoured cable for service connection 30 polycarbonated box for single phase consumer 31 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 32 pvc 4c x 16 sq.mm. armoured cable for service connection 33 polycarbonated box for three phase consumer 34 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 35 pcc pole, 8.5 mtr. long 36 stone pad ( 300x300x75mm ) 37 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 38 gi wire 6 swg 39 lt stay set ( 16 x 1800 mm ) 40 lt stay clamp with nut and bolt 41 stay wire 7 / 10 swg 42 lt stay insulator 43 dead end clamps with i hook ( insulated ) 44 suspension clamp with i hook 45 pole clamps with nut and bolt 46 holding clamp for round pole with nut and bolt 47 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 48 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 49 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 50 lt abc of 3x50+1x35+1x16 sq. mm 51 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 52 1x16 mm2 xlpe insulated al. cable for energising the street light 53 end cap for lt ab cable 54 pg clamps 55 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 56 pcc pole, 8.5 mtr. long 57 stone pad ( 300x300x75mm ) 58 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 59 gi wire 6 swg 60 lt stay set ( 16 x 1800 mm ) 61 lt stay clamp with nut and bolt 62 stay wire 7 / 10 swg 63 lt stay insulator 64 dead end clamps with i hook ( insulated ) 65 suspension clamp with i hook 66 pole clamps with nut and bolt 67 holding clamp for round pole with nut and bolt 68 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 69 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 70 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 71 lt abc of 3x95+1x70+1x16 sq. mm 72 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 73 1x16 mm2 xlpe insulated al. cable for energising the street light 74 end cap for lt ab cable 75 pg clamps 76 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 77 pcc pole, 8.5 mtr. long 78 stone pad ( 300x300x75mm ) 79 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 80 gi wire 6 swg 81 lt stay set ( 16 x 1800 mm ) 82 lt stay clamp with nut and bolt 83 stay wire 7 / 10 swg 84 lt stay insulator 85 dead end clamps with i hook ( insulated ) 86 suspension clamp with i hook 87 pole clamps with nut and bolt 88 holding clamp for round pole with nut and bolt 89 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 90 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 91 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 92 lt abc of 3x120+1x95+1x16 sq. mm 93 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 94 1x16 mm2 xlpe insulated al. cable for energising the street light 95 end cap for lt ab cable 96 pg clamps 97 feeder bifurcation ( 11 kv line ) 98 11kv new line on 11 mtr. st pole with acsr dog conductor ( feeder bifurcation 11 kv line ) 99 11 kv polymer disc insulator b&s type 70 kn 100 disc fitting b&s type 70 kn 101 11 kv composite polymer pin insulator with nut and washers 102 11kv smc danger board with clamp, bolts & nuts 103 11kv smc number plate for clamp with n&b 104 11 kv stay set ( 16 x 1800 mm ) 105 11 kv stay clamp with nut and bolt 106 stay wire 7 / 10 swg 107 11 kv stay insulator 108 acsr dog conductor 109 p.g. clamp for acsr dog / raccoon 110 armour rod with ferrule for acsr dog / panther / raccoon helical performed 111 11 mtr. stp 112 13 mtr. stp 113 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 114 aluminium binding wire 6 swg 115 aluminium jointing sleeves 116 g.i. barbed wire 117 gi wire 6 swg 118 gi wire 8 swg 119 gi wire 16 swg 120 eye bolt 121 turn buckle 122 red oxide paint 123 aluminium paint 124 11kv e bracket with n&b 125 11kv `f bracket with n&b 126 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 127 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 128 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 129 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 130 cross arm holding clamp with nuts & bolts 131 v type cross arm for 11kv line, 100x50x6 mm, gi 132 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 133 gi guarding angle iron 75x75x6 mm 3010 mm long 134 stone pad ( 300x300x75mm ) 135 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 136 11 kv polymer disc insulator b&s type 70 kn 137 disc fitting b&s type 70 kn 138 11 kv composite polymer pin insulator with nut and washers 139 11kv smc danger board with clamp, bolts & nuts 140 11kv smc number plate for clamp with n&b 141 11 kv stay set ( 16 x 1800 mm ) 142 11 kv stay clamp with nut and bolt 143 stay wire 7 / 10 swg 144 11 kv stay insulator 145 acsr dog conductor 146 p.g. clamp for acsr dog / raccoon 147 armour rod with ferrule for acsr dog / panther / raccoon helical performed 148 pcc pole, 8.5 mtr. long 149 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 150 aluminium binding wire 6 swg 151 aluminium jointing sleeves 152 g.i. barbed wire 153 gi wire 6 swg 154 gi wire 8 swg 155 gi wire 16 swg 156 eye bolt 157 turn buckle 158 11kv e bracket with n&b 159 11kv `f bracket with n&b 160 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 161 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 162 cross arm holding clamp with nuts & bolts 163 v type cross arm for 11kv line, 100x50x6 mm, gi 164 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 165 gi guarding angle iron 75x75x6 mm 3010 mm long 166 stone pad ( 300x300x75mm ) 167 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 168 11 kv railway crossing 169 11kv 3x185 mm2xlpe cable 170 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 171 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 172 cable route marker 173 g.i. pipe 6 dia . 174 11 mtr. stp 175 stone pad ( 300x300x75mm ) 176 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 177 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 178 11 kv polymer disc insulator b&s type 70 kn 179 disc fitting b&s type 70 kn 180 p.g. clamp for acsr dog / raccoon 181 11kv smc number plate for clamp with n&b 182 11kv smc danger board with clamp, bolts & nuts 183 g.i. barbed wire 184 aluminium binding wire 6 swg 185 aluminium paint 186 red oxide paint 187 11 kvstay set ( 16 x 1800 mm ) 188 11 kv stay clamp with nut and bolt 189 stay wire 7 / 10 swg 190 11 kv stay insulator 191 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 192 gi wire 6 swg 193 nhai / state highway crossing 194 11kv 3x185 mm2xlpe cable 195 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 196 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 197 cable route marker 198 g.i. pipe 6 dia . 199 11 mtr. stp 200 stone pad ( 300x300x75mm ) 201 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 202 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 203 11 kv polymer disc insulator b&s type 70 kn 204 disc fitting b&s type 70 kn 205 p.g. clamp for acsr dog / raccoon 206 11kv smc number plate for clamp with n&b 207 11kv smc danger board with clamp, bolts & nuts 208 g.i. barbed wire 209 aluminium binding wire 6 swg 210 aluminium paint 211 red oxide paint 212 11 kv stay set ( 16 x 1800 mm ) 213 11 kv stay clamp with nut and bolt 214 stay wire 7 / 10 swg 215 11 kv stay insulator 216 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 217 gi wire 6 swg 218 augumentation / reconductoring of 33 kv overhead line with dog conductor 219 acsr dog conductor 220 pcc pole, 9.0 mtr. long 221 11 mtr. stp 222 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 223 gi wire 6 swg 224 33 kv composite polymer pin insulator with nut and washers 225 aluminium paint 226 red oxide paint 227 33kv smc danger board with clamp and n&b 228 33kv smc number plate with clampand n&b 229 stone pad ( 300x300x75mm ) 230 g.i. barbed wire 231 33kv e bracket with n&b 232 33kv f bracket with n&b 233 v type cross arm for 33kv line 100x50x6 mm, gi 234 cross arm holding clamp with nuts & bolts 235 33 kv polymer disc insulator b&s type 70 kn 236 disc fitting b&s type 70 kn 237 33 kv stay set 238 33 kv stay clamp with nut and bolt 239 stay wire 7 / 8 swg 240 33 kv stay insulator 241 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 242 acsr dog conductor 243 11 kv polymer disc insulator b&s type 70 kn 244 disc fitting b&s type 70 kn 245 11 kv composite polymer pin insulator with nut and washers 246 11kv smc danger board with clamp, bolts & nuts 247 11kv smc number plate for clamp with n&b 248 11 kv stay set ( 16 x 1800 mm ) 249 11 kv stay clamp with nut and bolt 250 stay wire 7 / 10 swg 251 11 kv stay insulator 252 p.g. clamp for acsr dog / raccoon 253 armour rod with ferrule for acsr dog / panther / raccoon helical performed 254 pcc pole, 8.5 mtr. long 255 11 mtr. stp 256 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 257 aluminium binding wire 6 swg 258 aluminium jointing sleeves 259 g.i. barbed wire 260 gi wire 6 swg 261 gi wire 8 swg 262 gi wire 16 swg 263 eye bolt 264 turn buckle 265 red oxide paint 266 aluminium paint 267 11kv `f bracket with n&b 268 cross arm holding clamp with nuts & bolts 269 v type cross arm for 11kv line, 100x50x6 mm, gi 270 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 271 stone pad ( 300x300x75mm ) 272 11 kv agriculture feeder segregation & feeder splitting due to overloading 273 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 274 acsr rabbit conductor 275 11kv polymer disc insulator t&c type 45 kn 276 disc fittings t&c type 45 kn 277 11 kv composite polymer pin insulator with nut and washers 278 11kv smc danger board with clamp, bolts & nuts 279 11kv smc number plate for clamp with n&b 280 11 kv stay set ( 16 x 1800 mm ) 281 11 kv stay clamp with nut and bolt 282 stay wire 7 / 10 swg 283 11 kv stay insulator 284 pg clamps 285 armour rod with ferrule for acsr dog / panther / raccoon helical performed 286 pcc pole, 8.5 mtr. long 287 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 288 aluminium binding wire 6 swg 289 aluminium jointing sleeves 290 g.i. barbed wire 291 gi wire 6 swg 292 gi wire 8 swg 293 gi wire 16 swg 294 eye bolt 295 turn buckle 296 11kv e bracket with n&b 297 11kv `f bracket with n&b 298 gi top channel 100x50x2240 mm. 299 clamp with nuts & bolts for 1300 mm long gi channel 300 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 301 gi top channel 100x50x6, 1525 mm long 302 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 303 cross arm holding clamp with nuts & bolts 304 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 305 v type cross arm for 11kv line, 65x65x6 mm, gi angle 306 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 307 stone pad ( 300x300x75mm ) 308 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 309 pcc pole, 8.5 mtr. long 310 stone pad ( 300x300x75mm ) 311 lt clamp with nut and bolt for pcc pole 312 lt shakle insulator 100x115 mm 313 bolts and nuts for shackle insulators 314 acsr rabbit conductor 315 aluminium jointing sleeves 316 aluminium binding wire 6 swg 317 earth wire clamp 318 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 319 gi wire 6 swg 320 lt stay set ( 16 x 1800 mm ) 321 lt stay clamp with nut and bolt 322 stay wire 7 / 10 swg 323 lt stay insulator 324 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 325 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 326 pcc pole, 8.5 mtr. long 327 stone pad ( 300x300x75mm ) 328 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 329 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 330 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 331 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 332 gi channel 125x65x6, 1300mm ( tee off ) 333 clamp with nuts & bolts for 1300 mm long gi channel 334 11kv polymer disc insulator t&c type 45 kn 335 disc fittings t&c type 45 kn 336 11 kv composite polymer pin insulator with nut and washers 337 11kv tpmo complete set 338 11kv do fuse set ( 3 phase ) 339 11kv lightening arrestor 340 g.i. barbed wire 341 11kv smc danger board with clamp, bolts & nuts 342 deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 343 lt stay set ( 16 x 1800 mm ) 344 lt stay clamp with nut and bolt 345 stay wire 7 / 10 swg 346 lt stay insulator 347 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 348 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 349 lt pvc cable3.5x150 / 70sq.mm. 350 acsr weasel conductor 351 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 352 gi wire 6 swg 353 gi strip 25x3 mm 354 gi angle 100x50x2028mm ( fordistribution box ) ) 355 al. crimping lugs 150 sq.mm. 356 al. crimping lugs 70 sq.mm. 357 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 358 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 359 11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 360 pcc pole, 8.5 mtr. long 361 stone pad ( 300x300x75mm ) 362 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 363 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 364 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 365 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 366 gi channel 125x65x6, 1300mm ( tee off ) 367 clamp with nuts & bolts for 1300 mm long gi channel 368 11kv polymer disc insulator t&c type 45 kn 369 disc fittings t&c type 45 kn 370 11 kv composite polymer pin insulator with nut and washers 371 11kv tpmo complete set 372 11kv do fuse set ( 3 phase ) 373 11kv lightening arrestor 374 g.i. barbed wire 375 11kv smc danger board with clamp, bolts & nuts 376 deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 377 lt stay set ( 16 x 1800 mm ) 378 lt stay clamp with nut and bolt 379 stay wire 7 / 10 swg 380 lt stay insulator 381 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 382 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 383 lt pvc cable3.5x70 / 35sq.mm. 384 acsr weasel conductor 385 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 386 gi wire 6 swg 387 gi strip 25x3 mm 388 gi angle 100x50x2028mm ( fordistribution box ) ) 389 al. crimping lugs 70 sq.mm. 390 al. crimping lugs 35 sq.mm. 391 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 392 construction of new 25 kva, 11 / 0.433kv distribution transformer s / s 393 11 / 0.44 kv 25 kva transformer ( four star rating, level ii ) 394 pcc pole, 8.5 mtr. long 395 stone pad ( 300x300x75mm ) 396 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 397 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 398 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 399 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 400 gi channel 125x65x6, 1300mm ( tee off ) 401 clamp with nuts & bolts for 1300 mm long gi channel 402 11kv polymer disc insulator t&c type 45 kn 403 disc fittings t&c type 45 kn 404 11 kv composite polymer pin insulator with nut and washers 405 11kv tpmo complete set 406 11kv do fuse set ( 3 phase ) 407 11kv lightening arrestor 408 g.i. barbed wire 409 11kv smc danger board with clamp, bolts & nuts 410 deep drawn distribution boxas per technical specifications for 3 ph 25 kva dtr 411 lt stay set ( 16 x 1800 mm ) 412 lt stay clamp with nut and bolt 413 stay wire 7 / 10 swg 414 lt stay insulator 415 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 416 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 417 lt xlpe insulated unarmoured 4x25 sq. mm.cable 418 acsr weasel conductor 419 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 420 gi wire 6 swg 421 gi strip 25x3 mm 422 gi angle 100x50x2028mm ( fordistribution box ) ) 423 al. crimping lugs 25 sq.mm. 424 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 425 installation of 11 kv outgoing vcb for feeder segreration 426 11kv outgoing ctr 400 / 200 / 5a 350 mva 427 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 428 11kv 3x185 mm2xlpe cable 429 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 430 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 431 11 mtr. stp 432 gi top channel 100x50x2240 mm. 433 stone pad ( 300x300x75mm ) 434 11 kv polymer disc insulator b&s type 70 kn 435 disc fitting b&s type 70 kn 436 11 kv composite polymer pin insulator with nut and washers 437 p.g. clamp for acsr dog / raccoon 438 11kv e bracket with n&b 439 11kv smc number plate for clamp with n&b 440 11kv smc danger board with clamp, bolts & nuts 441 gi channel 125x65x2028 mm long ( dropper for fuse set ) 442 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 443 11kv tpmo complete set 444 11kv do fuse set ( 3 phase ) 445 11kv lightening arrestor 446 g.i. barbed wire 447 aluminium binding wire 6 swg 448 aluminium paint 449 red oxide paint 450 11 kv stay set ( 16 x 1800 mm ) 451 11 kv stay clamp with nut and bolt 452 stay wire 7 / 10 swg 453 11 kv stay insulator 454 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 455 gi strip 50x6 mm 456 gi wire 6 swg 457 g.i. pipe 6 dia . 458 11 kv railway crossing 459 11kv 3x185 mm2xlpe cable 460 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 461 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 462 cable route marker 463 g.i. pipe 6 dia . 464 11 mtr. stp 465 stone pad ( 300x300x75mm ) 466 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 467 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 468 11 kv polymer disc insulator b&s type 70 kn 469 disc fitting b&s type 70 kn 470 p.g. clamp for acsr dog / raccoon 471 11kv smc number plate for clamp with n&b 472 11kv smc danger board with clamp, bolts & nuts 473 g.i. barbed wire 474 aluminium binding wire 6 swg 475 aluminium paint 476 red oxide paint 477 11 kvstay set ( 16 x 1800 mm ) 478 11 kv stay clamp with nut and bolt 479 stay wire 7 / 10 swg 480 11 kv stay insulator 481 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 482 gi wire 6 swg 483 nhai / state highway crossing 484 11kv 3x185 mm2xlpe cable 485 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 486 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 487 cable route marker 488 g.i. pipe 6 dia . 489 11 mtr. stp 490 stone pad ( 300x300x75mm ) 491 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 492 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 493 11 kv polymer disc insulator b&s type 70 kn 494 disc fitting b&s type 70 kn 495 p.g. clamp for acsr dog / raccoon 496 11kv smc number plate for clamp with n&b 497 11kv smc danger board with clamp, bolts & nuts 498 g.i. barbed wire 499 aluminium binding wire 6 swg 500 aluminium paint 501 red oxide paint 502 11 kv stay set ( 16 x 1800 mm ) 503 11 kv stay clamp with nut and bolt 504 stay wire 7 / 10 swg 505 11 kv stay insulator 506 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 507 gi wire 6 swg 508 requirement of extra ab cable for new additional ckt at dts 509 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 510 pcc pole, 8.5 mtr. long 511 11 mtr. stp 512 stone pad ( 300x300x75mm ) 513 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 514 gi wire 6 swg 515 lt stay set ( 16 x 1800 mm ) 516 lt stay clamp with nut and bolt 517 stay wire 7 / 10 swg 518 lt stay insulator 519 dead end clamps with i hook ( insulated ) 520 suspension clamp with i hook 521 pole clamps with nut and bolt 522 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 523 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 524 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 525 lt abc of 3x50+1x35+1x16 sq. mm 526 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 527 end cap for lt ab cable 528 pg clamps 529 1x16 mm2 xlpe insulated al. cable for energising the street light 530 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 531 pcc pole, 8.5 mtr. long 532 11 mtr. stp 533 stone pad ( 300x300x75mm ) 534 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 535 gi wire 6 swg 536 lt stay set ( 16 x 1800 mm ) 537 lt stay clamp with nut and bolt 538 stay wire 7 / 10 swg 539 lt stay insulator 540 dead end clamps with i hook ( insulated ) 541 suspension clamp with i hook 542 pole clamps with nut and bolt 543 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 544 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 545 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 546 lt abc of 3x95+1x70+1x16 sq. mm 547 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 548 end cap for lt ab cable 549 pg clamps 550 1x16 mm2 xlpe insulated al. cable for energising the street light 551 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 552 pcc pole, 8.5 mtr. long 553 11 mtr. stp 554 stone pad ( 300x300x75mm ) 555 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 556 gi wire 6 swg 557 lt stay set ( 16 x 1800 mm ) 558 lt stay clamp with nut and bolt 559 stay wire 7 / 10 swg 560 lt stay insulator 561 dead end clamps with i hook ( insulated ) 562 suspension clamp with i hook 563 pole clamps with nut and bolt 564 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 565 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 566 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 567 lt abc of 3x120+1x95+1x16 sq. mm 568 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 569 end cap for lt ab cable 570 pg clamps 571 1x16 mm2 xlpe insulated al. cable for energising the street light 572 additional items that may be required for completion of work 573 3x120 sq. mm 11 kv ab cable 574 11kv polymer disc insulator with fitting for 11 kvabc 575 11kv polymer disc insulators with i hook 576 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 577 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 578 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 579 33kv 3x300 mm2xlpe cable 580 lt xlpe insulated unarmoured 1x50 sq. mm. cable 581 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 582 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 583 loop guard complete, 3 phase 584 spacers lt pvc 585 mid span jointing sleeves ( 95 sq. mm ) 586 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 587 supply of on / off switch for street light connections 588 height raising channel 100x50, 2240 mm long 589 back clamp for height raising channel holding clamps with bolts & nuts 590 cable jointing kit straight through ( 3x185 sqmm ) 591 cable jointing kit straight through ( 3x300sqmm ) 592 extra prefabricated gi items like clamp, channel, angle with nut & bolt 593 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 594 erection of pcc pole, 8.5 mtr. long 595 fixing of bolts and nuts for shackle insulators 596 fixing of lt shakle insulator 100x115 mm 597 fixing of d straps 598 stringing of lt xlpe armoured 3.5x50 sq. mm. cable 599 fixing of mid span jointing sleeves ( 120 sq. mm ) 600 fixing of insulating piercing connector ( 50 150 sq.mm ) 601 fixing of insulation mastic tape ( 2inc x 10 feet ) . 602 fixing of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 603 fixing of single phase deep drawn distribution box with clamps and suitable lock and key arrangment 604 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 605 1x16 mm2 xlpe insulated al. cable for energising the street light 606 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 607 gi wire 6 swg 608 erection of lt stay set ( 16 x 1800 mm ) 609 fixing of lt stay clamp with nut and bolt 610 erection of stay wire 7 / 10 swg 611 fixing of lt stay insulator 612 concreting of stay set ( 16x 1800 mm ) 613 stone pad ( 300x300x75mm ) 614 fixing of lt clamp with nut and bolt for pcc pole 615 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 616 concreting of pole / support ( 0.268 cu.m. ) 617 fixing of angle for vertical arm l50x50x6 ( type a ) 618 fixing of angle for vertical arm l50x50x6 ( type b ) 619 fixing of top clamp for vertical arm ( type a ) 620 fixing of top clamp for vertical arm ( type b ) 621 fixing of bottom clamp for vertical arm ( type a ) 622 fixing of bottom clamp for vertical arm ( type b ) 623 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 624 stringing of pvc 2c x 6 sq.mm. armoured cable for service connection 625 dismanting of old line service cable and connection of new armoured cable 626 fixing of polycarbonated box for single phase consumer 627 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 628 stringing of pvc 4c x 16 sq.mm. armoured cable for service connection 629 dismanting of old line service cable and connection of new armoured cable 630 fixing of polycarbonated box for three phase consumer 631 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 632 erection of pcc pole, 8.5 mtr. long 633 stone pad ( 300x300x75mm ) 634 concreting of pole / support ( 0.268 cu.m. ) 635 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 636 gi wire 6 swg 637 erection of lt stay set ( 16 x 1800 mm ) 638 fixing of lt stay clamp with nut and bolt 639 erection of stay wire 7 / 10 swg 640 fixing of lt stay insulator 641 concreting of stay set ( 16x 1800 mm ) 642 fixing of dead end clamps with i hook ( insulated ) 643 fixing of suspension clamp with i hook 644 fixing of pole clamps with nut and bolt 645 fixing of holding clamp for round pole with nut and bolt 646 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 647 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 648 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 649 stringing of lt abc of 3x50+1x35+1x16 sq. mm 650 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 651 1x16 mm2 xlpe insulated al. cable for energising the street light 652 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 653 fixing of end cap for lt ab cable 654 fixing of pg clamps 655 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 656 erection of pcc pole, 8.5 mtr. long 657 stone pad ( 300x300x75mm ) 658 concreting of pole / support ( 0.268 cu.m. ) 659 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 660 gi wire 6 swg 661 erection of lt stay set ( 16 x 1800 mm ) 662 fixing of lt stay clamp with nut and bolt 663 erection of stay wire 7 / 10 swg 664 fixing of lt stay insulator 665 concreting of stay set ( 16x 1800 mm ) 666 dead end clamps with i hook ( insulated ) 667 fixing of suspension clamp with i hook 668 fixing of pole clamps with nut and bolt 669 holding clamp for round pole with nut and bolt 670 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 671 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 672 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 673 stringing of lt abc of 3x95+1x70+1x16 sq. mm 674 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 675 1x16 mm2 xlpe insulated al. cable for energising the street light 676 end cap for lt ab cable 677 fixing of pg clamps 678 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 679 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 680 erection of pcc pole, 8.5 mtr. long 681 stone pad ( 300x300x75mm ) 682 concreting of pole / support ( 0.268 cu.m. ) 683 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 684 gi wire 6 swg 685 erection of lt stay set ( 16 x 1800 mm ) 686 fixing of lt stay clamp with nut and bolt 687 erection of stay wire 7 / 10 swg 688 fixing of lt stay insulator 689 concreting of stay set ( 16x 1800 mm ) 690 dead end clamps with i hook ( insulated ) 691 fixing of suspension clamp with i hook 692 fixing of pole clamps with nut and bolt 693 holding clamp for round pole with nut and bolt 694 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 695 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 696 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 697 stringing of lt abc of 3x120+1x95+1x16 sq. mm 698 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 699 1x16 mm2 xlpe insulated al. cable for energising the street light 700 end cap for lt ab cable 701 fixing of pg clamps 702 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 703 feeder bifurcation ( 11 kv line ) 704 11kv new line on 11 mtr. st pole with acsr dog conductor 705 erection of 11 kv polymer disc insulator b&s type 70 kn 706 erection of disc fitting b&s type 70 kn 707 erection of 11 kv composite polymer pin insulator with nut and washers 708 fixing of 11kv smc danger board with clamp, bolts & nuts 709 fixing of 11kv smc number plate for clamp with n&b 710 erection of 11 kv stay set ( 16 x 1800 mm ) 711 fixing of 11 kv stay clamp with nut and bolt 712 erection of stay wire 7 / 10 swg 713 fixing of 11 kv stay insulator 714 concreting of stay set ( 16x 1800 mm ) 715 stringing of acsr dog conductor 716 fixing of p.g. clamp for acsr dog / raccoon 717 armour rod with ferrule for acsr dog / panther / raccoon helical performed 718 erection of 11 mtr. stp 719 erection of 13 mtr. stp 720 concreting of pole / support ( 0.44 cu.m. ) 721 concreting of pole ( 0.64 cu.m. ) 722 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 723 aluminium binding wire 6 swg 724 aluminium jointing sleeves 725 g.i. barbed wire 726 gi wire 6 swg 727 gi wire 8 swg 728 gi wire 16 swg 729 eye bolt 730 turn buckle 731 painting of st pole with red oxide paint 732 painting of st pole with aluminium paint 733 erection of 11kv e bracket with n&b 734 erection of 11kv `f bracket with n&b 735 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 736 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 737 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 738 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 739 cross arm holding clamp with nuts & bolts 740 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 741 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 742 gi guarding angle iron 75x75x6 mm 3010 mm long 743 tree cutting compensation 744 stone pad ( 300x300x75mm ) 745 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 746 erection of 11 kv polymer disc insulator b&s type 70 kn 747 erection of disc fitting b&s type 70 kn 748 erection of 11 kv composite polymer pin insulator with nut and washers 749 fixing of 11kv smc danger board with clamp, bolts & nuts 750 fixing of 11kv smc number plate for clamp with n&b 751 erection of 11 kv stay set ( 16 x 1800 mm ) 752 fixing of 11 kv stay clamp with nut and bolt 753 erection of stay wire 7 / 10 swg 754 fixing of 11 kv stay insulator 755 concreting of stay set ( 16x 1800 mm ) 756 stringing of acsr dog conductor 757 fixing of p.g. clamp for acsr dog / raccoon 758 armour rod with ferrule for acsr dog / panther / raccoon helical performed 759 erection of pcc pole, 8.5 mtr. long 760 concreting of pole / support ( 0.268 cu.m. ) 761 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 762 aluminium binding wire 6 swg 763 aluminium jointing sleeves 764 g.i. barbed wire 765 gi wire 6 swg 766 gi wire 8 swg 767 gi wire 16 swg 768 eye bolt 769 turn buckle 770 erection of 11kv e bracket with n&b 771 erection of 11kv `f bracket with n&b 772 gi top channel 125x65mm, 3200 mm with clamp, bolts, nuts and washers 773 gi angle 65x65x6mm, 4300 mm long bracing with 4 clamps, bolts, nuts and washers 774 cross arm holding clamp with nuts & bolts 775 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 776 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 777 gi guarding angle iron 75x75x6 mm 3010 mm long 778 tree cutting compensation 779 stone pad ( 300x300x75mm ) 780 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 781 11 kv railway crossing 782 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 783 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 784 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 785 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 786 cable route marker 787 g.i. pipe 6 dia . 788 erection of 11 mtr. stp 789 stone pad ( 300x300x75mm ) 790 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 791 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 792 erection of 11 kv polymer disc insulator b&s type 70 kn 793 erection of disc fitting b&s type 70 kn 794 fixing of p.g. clamp for acsr dog / raccoon 795 fixing of 11kv smc number plate for clamp with n&b 796 fixing of 11kv smc danger board with clamp, bolts & nuts 797 g.i. barbed wire 798 aluminium binding wire 6 swg 799 painting of st pole with aluminium paint 800 painting of st pole with red oxide paint 801 erection of 11 kvstay set ( 16 x 1800 mm ) 802 fixing of 11 kv stay clamp with nut and bolt 803 erection of stay wire 7 / 10 swg 804 fixing of 11 kv stay insulator 805 concreting of stay set ( 16x 1800 mm ) 806 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 807 gi wire 6 swg 808 concreting of pole / support ( 0.44 cu.m. ) 809 railway crossing documentation, land and approval fee etc. 810 nhai / state highway crossing 811 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 812 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 813 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 814 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 815 cable route marker 816 g.i. pipe 6 dia . 817 erection of 11 mtr. stp 818 stone pad ( 300x300x75mm ) 819 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 820 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 821 erection of 11 kv polymer disc insulator b&s type 70 kn 822 disc fitting b&s type 70 kn 823 fixing of p.g. clamp for acsr dog / raccoon 824 fixing of 11kv smc number plate for clamp with n&b 825 fixing of 11kv smc danger board with clamp, bolts & nuts 826 g.i. barbed wire 827 aluminium binding wire 6 swg 828 painting of st pole with aluminium paint 829 painting of st pole with red oxide paint 830 erection of 11 kv stay set ( 16 x 1800 mm ) 831 fixing of 11 kv stay clamp with nut and bolt 832 erection of stay wire 7 / 10 swg 833 fixing of 11 kv stay insulator 834 concreting of stay set ( 16x 1800 mm ) 835 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 836 gi wire 6 swg 837 concreting of pole / support ( 0.44 cu.m. ) 838 nhai / state highway crossing documentation, land charges and approval fee etc. 839 road restoration charges 840 augumentation / reconductoring of 33 kv overhead line with dog conductor 841 stringing of acsr dog conductor 842 erection of pcc pole, 9.0 mtr. long 843 erection of 11 mtr. stp 844 concreting of pole / support ( 0.286 cu.m. ) 845 concreting of pole / support ( 0.44 cu.m. ) 846 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 847 gi wire 6 swg 848 erection of 33 kv composite polymer pin insulator with nut and washers 849 painting of st pole with aluminium paint 850 painting of st pole with red oxide paint 851 fixing of 33kv smc danger board with clamp and n&b 852 fixing of 33kv smc number plate with clampand n&b 853 stone pad ( 300x300x75mm ) 854 g.i. barbed wire 855 erection of 33kv e bracket with n&b 856 erection of 33kv f bracket with n&b 857 erection of v type cross arm for 33kv line 100x50x6 mm, gi 858 cross arm holding clamp with nuts & bolts 859 erection of 33 kv polymer disc insulator b&s type 70 kn 860 disc fitting b&s type 70 kn 861 erection of 33 kv stay set 862 fixing of 33 kv stay clamp with nut and bolt 863 erection of stay wire 7 / 8 swg 864 fixing of 33 kv stay insulator 865 concreting of 33 kv stay set 866 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 867 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 868 stringing of acsr dog conductor 869 erection of 11 kv polymer disc insulator b&s type 70 kn 870 disc fitting b&s type 70 kn 871 erection of 11 kv composite polymer pin insulator with nut and washers 872 fixing of 11kv smc danger board with clamp, bolts & nuts 873 fixing of 11kv smc number plate for clamp with n&b 874 erection of 11 kv stay set ( 16 x 1800 mm ) 875 fixing of 11 kv stay clamp with nut and bolt 876 erection of stay wire 7 / 10 swg 877 fixing of 11 kv stay insulator 878 concreting of stay set ( 16x 1800 mm ) 879 fixing of p.g. clamp for acsr dog / raccoon 880 armour rod with ferrule for acsr dog / panther / raccoon helical performed 881 erection of pcc pole, 8.5 mtr. long 882 erection of 11 mtr. stp 883 concreting of pole / support ( 0.268 cu.m. ) 884 concreting of pole / support ( 0.44 cu.m. ) 885 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 886 aluminium binding wire 6 swg 887 aluminium jointing sleeves 888 g.i. barbed wire 889 gi wire 6 swg 890 gi wire 8 swg 891 gi wire 16 swg 892 eye bolt 893 turn buckle 894 painting of st pole with red oxide paint 895 painting of st pole with aluminium paint 896 erection of 11kv `f bracket with n&b 897 cross arm holding clamp with nuts & bolts 898 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 899 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 900 stone pad ( 300x300x75mm ) 901 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 902 11 kv agriculture feeder segregation & feeder splitting due to overloading 903 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 904 stringing of acsr rabbit conductor 905 erection of 11kv polymer disc insulator t&c type 45 kn 906 disc fittings t&c type 45 kn 907 erection of 11 kv composite polymer pin insulator with nut and washers 908 fixing of 11kv smc danger board with clamp, bolts & nuts 909 fixing of 11kv smc number plate for clamp with n&b 910 erection of 11 kv stay set ( 16 x 1800 mm ) 911 fixing of 11 kv stay clamp with nut and bolt 912 erection of stay wire 7 / 10 swg 913 fixing of 11 kv stay insulator 914 concreting of stay set ( 16x 1800 mm ) 915 fixing of pg clamps 916 armour rod with ferrule for acsr dog / panther / raccoon helical performed 917 erection of pcc pole, 8.5 mtr. long 918 concreting of pole / support ( 0.268 cu.m. ) 919 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 920 aluminium binding wire 6 swg 921 aluminium jointing sleeves 922 g.i. barbed wire 923 gi wire 6 swg 924 gi wire 8 swg 925 gi wire 16 swg 926 eye bolt 927 turn buckle 928 erection of 11kv e bracket with n&b 929 erection of 11kv `f bracket with n&b 930 gi top channel 100x50x2240 mm. 931 clamp with nuts & bolts for 1300 mm long gi channel 932 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 933 gi top channel 100x50x6, 1525 mm long 934 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 935 cross arm holding clamp with nuts & bolts 936 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 937 erection of v type cross arm for 11kv line, 65x65x6 mm, gi angle 938 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 939 tree cutting compensation 940 stone pad ( 300x300x75mm ) 941 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 942 erection of pcc pole, 8.5 mtr. long 943 stone pad ( 300x300x75mm ) 944 lt clamp with nut and bolt for pcc pole 945 lt shakle insulator 100x115 mm 946 bolts and nuts for shackle insulators 947 concreting of pole / support ( 0.268 cu.m. ) 948 stringing of acsr rabbit conductor 949 aluminium jointing sleeves 950 aluminium binding wire 6 swg 951 earth wire clamp 952 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 953 gi wire 6 swg 954 erection of lt stay set ( 16 x 1800 mm ) 955 fixing of lt stay clamp with nut and bolt 956 erection of stay wire 7 / 10 swg 957 fixing of lt stay insulator 958 concreting of stay set ( 16x 1800 mm ) 959 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 960 installation of 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 961 erection of pcc pole, 8.5 mtr. long 962 stone pad ( 300x300x75mm ) 963 concreting of pole / support ( 0.268 cu.m. ) 964 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 965 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 966 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 967 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 968 gi channel 125x65x6, 1300mm ( tee off ) 969 clamp with nuts & bolts for 1300 mm long gi channel 970 erection of 11kv polymer disc insulator t&c type 45 kn 971 disc fittings t&c type 45 kn 972 erection of 11 kv composite polymer pin insulator with nut and washers 973 erection of 11kv tpmo complete set 974 erection of 11kv do fuse set ( 3 phase ) 975 erection of 11kv lightening arrestor 976 g.i. barbed wire 977 fixing of 11kv smc danger board with clamp, bolts & nuts 978 fixing of deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 979 erection of lt stay set ( 16 x 1800 mm ) 980 fixing of lt stay clamp with nut and bolt 981 erection of stay wire 7 / 10 swg 982 fixing of lt stay insulator 983 concreting of stay set ( 16x 1800 mm ) 984 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 985 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 986 lt pvc cable3.5x150 / 70sq.mm. 987 acsr weasel conductor 988 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 989 gi wire 6 swg 990 gi strip 25x3 mm 991 gi angle 100x50x2028mm ( fordistribution box ) ) 992 al. crimping lugs 150 sq.mm. 993 al. crimping lugs 70 sq.mm. 994 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 995 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 996 installation of11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 997 erection of pcc pole, 8.5 mtr. long 998 stone pad ( 300x300x75mm ) 999 concreting of pole / support ( 0.268 cu.m. ) 1000 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1001 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 1002 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1003 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 1004 gi channel 125x65x6, 1300mm ( tee off ) 1005 clamp with nuts & bolts for 1300 mm long gi channel 1006 erection of 11kv polymer disc insulator t&c type 45 kn 1007 disc fittings t&c type 45 kn 1008 erection of 11 kv composite polymer pin insulator with nut and washers 1009 erection of 11kv tpmo complete set 1010 erection of 11kv do fuse set ( 3 phase ) 1011 erection of 11kv lightening arrestor 1012 g.i. barbed wire 1013 fixing of 11kv smc danger board with clamp, bolts & nuts 1014 fixing of deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 1015 erection of lt stay set ( 16 x 1800 mm ) 1016 fixing of lt stay clamp with nut and bolt 1017 erection of stay wire 7 / 10 swg 1018 fixing of lt stay insulator 1019 concreting of stay set ( 16x 1800 mm ) 1020 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 1021 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 1022 lt pvc cable3.5x70 / 35sq.mm. 1023 acsr weasel conductor 1024 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1025 gi wire 6 swg 1026 gi strip 25x3 mm 1027 gi angle 100x50x2028mm ( fordistribution box ) ) 1028 al. crimping lugs 70 sq.mm. 1029 al. crimping lugs 35 sq.mm. 1030 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 1031 construction of new 25 kva, 11 / 0.433kv distribution transformer s / s 1032 installation of11 / 0.44 kv 25 kva transformer ( four star rating, level ii ) 1033 erection of pcc pole, 8.5 mtr. long 1034 stone pad ( 300x300x75mm ) 1035 concreting of pole / support ( 0.268 cu.m. ) 1036 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1037 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 1038 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1039 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 1040 gi channel 125x65x6, 1300mm ( tee off ) 1041 clamp with nuts & bolts for 1300 mm long gi channel 1042 erection of 11kv polymer disc insulator t&c type 45 kn 1043 disc fittings t&c type 45 kn 1044 erection of 11 kv composite polymer pin insulator with nut and washers 1045 erection of 11kv tpmo complete set 1046 erection of 11kv do fuse set ( 3 phase ) 1047 erection of 11kv lightening arrestor 1048 g.i. barbed wire 1049 fixing of 11kv smc danger board with clamp, bolts & nuts 1050 fixing of deep drawn distribution boxas per technical specifications for 3 ph 25 kva dtr 1051 erection of lt stay set ( 16 x 1800 mm ) 1052 fixing of lt stay clamp with nut and bolt 1053 erection of stay wire 7 / 10 swg 1054 fixing of lt stay insulator 1055 concreting of stay set ( 16x 1800 mm ) 1056 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 1057 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 1058 lt xlpe insulated unarmoured 4x25 sq. mm.cable 1059 acsr weasel conductor 1060 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1061 gi wire 6 swg 1062 gi strip 25x3 mm 1063 gi angle 100x50x2028mm ( fordistribution box ) ) 1064 al. crimping lugs 25 sq.mm. 1065 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 1066 installation of 11 kv outgoing vcb for feeder segreration 1067 installation of 11kv outgoing ctr 400 / 200 / 5a 350 mva 1068 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 1069 11kv 3x185 mm2xlpe cable 1070 laying of 11 kv cable including cost of sand & bricks 1071 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1072 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1073 erection of 11 mtr. stp 1074 gi top channel 100x50x2240 mm. 1075 stone pad ( 300x300x75mm ) 1076 erection of 11 kv polymer disc insulator b&s type 70 kn 1077 disc fitting b&s type 70 kn 1078 erection of 11 kv composite polymer pin insulator with nut and washers 1079 fixing of p.g. clamp for acsr dog / raccoon 1080 erection of 11kv e bracket with n&b 1081 fixing of 11kv smc number plate for clamp with n&b 1082 fixing of 11kv smc danger board with clamp, bolts & nuts 1083 gi channel 125x65x2028 mm long ( dropper for fuse set ) 1084 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1085 erection of 11kv tpmo complete set 1086 erection of 11kv do fuse set ( 3 phase ) 1087 erection of 11kv lightening arrestor 1088 g.i. barbed wire 1089 aluminium binding wire 6 swg 1090 painting of st pole with aluminium paint 1091 painting of st pole with red oxide paint 1092 erection of 11 kv stay set ( 16 x 1800 mm ) 1093 fixing of 11 kv stay clamp with nut and bolt 1094 erection of stay wire 7 / 10 swg 1095 fixing of 11 kv stay insulator 1096 concreting of stay set ( 16x 1800 mm ) 1097 concreting of pole / support ( 0.44 cu.m. ) 1098 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1099 gi strip 50x6 mm 1100 gi wire 6 swg 1101 g.i. pipe 6 dia . 1102 control room extension 1103 extension of existing substationcontrol room building. ( as per annexure attached in tender documents. ) 1104 11 kv railway crossing 1105 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1106 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1107 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1108 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1109 cable route marker 1110 g.i. pipe 6 dia . 1111 erection of 11 mtr. stp 1112 stone pad ( 300x300x75mm ) 1113 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1114 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1115 erection of 11 kv polymer disc insulator b&s type 70 kn 1116 disc fitting b&s type 70 kn 1117 fixing of p.g. clamp for acsr dog / raccoon 1118 fixing of 11kv smc number plate for clamp with n&b 1119 fixing of 11kv smc danger board with clamp, bolts & nuts 1120 g.i. barbed wire 1121 aluminium binding wire 6 swg 1122 painting of st pole with aluminium paint 1123 painting of st pole with red oxide paint 1124 erection of 11 kvstay set ( 16 x 1800 mm ) 1125 fixing of 11 kv stay clamp with nut and bolt 1126 erection of stay wire 7 / 10 swg 1127 fixing of 11 kv stay insulator 1128 concreting of stay set ( 16x 1800 mm ) 1129 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1130 gi wire 6 swg 1131 concreting of pole / support ( 0.44 cu.m. ) 1132 railway crossing documentation, land and approval fee etc. 1133 nhai / state highway crossing 1134 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1135 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1136 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1137 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1138 cable route marker 1139 g.i. pipe 6 dia . 1140 erection of 11 mtr. stp 1141 stone pad ( 300x300x75mm ) 1142 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1143 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1144 erection of 11 kv polymer disc insulator b&s type 70 kn 1145 disc fitting b&s type 70 kn 1146 fixing of p.g. clamp for acsr dog / raccoon 1147 fixing of 11kv smc number plate for clamp with n&b 1148 fixing of 11kv smc danger board with clamp, bolts & nuts 1149 g.i. barbed wire 1150 aluminium binding wire 6 swg 1151 painting of st pole with aluminium paint 1152 painting of st pole with red oxide paint 1153 erection of 11 kv stay set ( 16 x 1800 mm ) 1154 fixing of 11 kv stay clamp with nut and bolt 1155 erection of stay wire 7 / 10 swg 1156 fixing of 11 kv stay insulator 1157 concreting of stay set ( 16x 1800 mm ) 1158 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1159 gi wire 6 swg 1160 concreting of pole / support ( 0.44 cu.m. ) 1161 nhai / state highway crossing documentation, land charges and approval fee etc. 1162 road restoration charges 1163 requirement of extra ab cable for new additional ckt at dts 1164 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 1165 erection of pcc pole, 8.5 mtr. long 1166 erection of 11 mtr. stp 1167 stone pad ( 300x300x75mm ) 1168 concreting of pole / support ( 0.268 cu.m. ) 1169 concreting of pole / support ( 0.44 cu.m. ) 1170 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1171 gi wire 6 swg 1172 erection of lt stay set ( 16 x 1800 mm ) 1173 fixing of lt stay clamp with nut and bolt 1174 erection of stay wire 7 / 10 swg 1175 fixing of lt stay insulator 1176 concreting of stay set ( 16x 1800 mm ) 1177 dead end clamps with i hook ( insulated ) 1178 fixing of suspension clamp with i hook 1179 fixing of pole clamps with nut and bolt 1180 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1181 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1182 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1183 stringing of lt abc of 3x50+1x35+1x16 sq. mm 1184 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1185 end cap for lt ab cable 1186 fixing of pg clamps 1187 1x16 mm2 xlpe insulated al. cable for energising the street light 1188 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 1189 erection of pcc pole, 8.5 mtr. long 1190 erection of 11 mtr. stp 1191 stone pad ( 300x300x75mm ) 1192 concreting of pole / support ( 0.268 cu.m. ) 1193 concreting of pole / support ( 0.44 cu.m. ) 1194 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1195 gi wire 6 swg 1196 erection of lt stay set ( 16 x 1800 mm ) 1197 fixing of lt stay clamp with nut and bolt 1198 erection of stay wire 7 / 10 swg 1199 fixing of lt stay insulator 1200 concreting of stay set ( 16x 1800 mm ) 1201 dead end clamps with i hook ( insulated ) 1202 fixing of suspension clamp with i hook 1203 fixing of pole clamps with nut and bolt 1204 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1205 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1206 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1207 stringing of lt abc of 3x95+1x70+1x16 sq. mm 1208 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1209 end cap for lt ab cable 1210 fixing of pg clamps 1211 1x16 mm2 xlpe insulated al. cable for energising the street light 1212 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 1213 erection of pcc pole, 8.5 mtr. long 1214 erection of 11 mtr. stp 1215 stone pad ( 300x300x75mm ) 1216 concreting of pole / support ( 0.268 cu.m. ) 1217 concreting of pole / support ( 0.44 cu.m. ) 1218 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1219 gi wire 6 swg 1220 erection of lt stay set ( 16 x 1800 mm ) 1221 fixing of lt stay clamp with nut and bolt 1222 erection of stay wire 7 / 10 swg 1223 fixing of lt stay insulator 1224 concreting of stay set ( 16x 1800 mm ) 1225 dead end clamps with i hook ( insulated ) 1226 fixing of suspension clamp with i hook 1227 fixing of pole clamps with nut and bolt 1228 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1229 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1230 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1231 stringing of lt abc of 3x120+1x95+1x16 sq. mm 1232 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1233 end cap for lt ab cable 1234 fixing of pg clamps 1235 1x16 mm2 xlpe insulated al. cable for energising the street light 1236 additional items that may be required for completion of work 1237 3x120 sq. mm 11 kv ab cable 1238 11kv polymer disc insulator with fitting for 11 kvabc 1239 11kv polymer disc insulators with i hook 1240 erection & concreting of extra stud pole complete with clamps, 1241 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 1242 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 1243 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 1244 lt xlpe insulated unarmoured 1x50 sq. mm. cable 1245 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 1246 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 1247 laying of 3x300 sq. mm. 33 kv xlpe insulated cable underground in hdpe pipe or trenches ( for railway / road crossing ) 1248 drilling & laying of ht underground cable using hdd method without using hdpe pipe 1249 loop guard complete, 3 phase 1250 spacers lt pvc 1251 mid span jointing sleeves ( 95 sq. mm ) 1252 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 1253 fixing of on / off switch for street light connections 1254 mounting of cable on dp structure ( including loop and riser ) 1255 height raising channel 100x50, 2240 mm long 1256 back clamp for height raising channel holding clamps with bolts & nuts 1257 cable jointing kit straight through ( 3x185 sqmm ) 1258 cable jointing kit straight through ( 3x300sqmm ) 1259 extra prefabricated gi items like clamp, channel, angle with nut & bolt...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32106663 development of distribution infrastructure for loss reduction works atdistrict ghaziabad and g b nagar of uttar pradesh under revamped reforms based and results linked, distribution sector scheme 1 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 2 pcc pole, 8.5 mtr. long 3 bolts and nuts for shackle insulators 4 lt shakle insulator 100x115 mm 5 d straps 6 lt xlpe armoured 3.5x50 sq. mm. cable 7 mid span jointing sleeves ( 50 sq. mm ) 8 insulating piercing connector ( 50 150 sq.mm ) 9 insulation mastic tape ( 2inc x 10 feet ) . 10 supply of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 11 supply of single of phase deep drawn distribution box with clamps and suitable lock and key arrangment 12 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 13 1x16 mm2 xlpe insulated al. cable for energising the street light 14 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 15 gi wire 6 swg 16 lt stay set ( 16 x 1800 mm ) 17 lt stay clamp with nut and bolt 18 stay wire 7 / 10 swg 19 lt stay insulator 20 stone pad ( 300x300x75mm ) 21 lt clamp with nut and bolt for pcc pole 22 angle for vertical arm l50x50x6 ( type a ) 23 angle for vertical arm l50x50x6 ( type b ) 24 top clamp for vertical arm ( type a ) 25 top clamp for vertical arm ( type b ) 26 bottom clamp for vertical arm ( type a ) 27 bottom clamp for vertical arm ( type b ) 28 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 29 pvc 2c x 6 sq.mm. armoured cable for service connection 30 polycarbonated box for single phase consumer 31 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 32 pvc 4c x 16 sq.mm. armoured cable for service connection 33 polycarbonated box for three phase consumer 34 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 35 pcc pole, 8.5 mtr. long 36 stone pad ( 300x300x75mm ) 37 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 38 gi wire 6 swg 39 lt stay set ( 16 x 1800 mm ) 40 lt stay clamp with nut and bolt 41 stay wire 7 / 10 swg 42 lt stay insulator 43 dead end clamps with i hook ( insulated ) 44 suspension clamp with i hook 45 pole clamps with nut and bolt 46 holding clamp for round pole with nut and bolt 47 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 48 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 49 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 50 lt abc of 3x50+1x35+1x16 sq. mm 51 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 52 1x16 mm2 xlpe insulated al. cable for energising the street light 53 end cap for lt ab cable 54 pg clamps 55 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 56 pcc pole, 8.5 mtr. long 57 stone pad ( 300x300x75mm ) 58 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 59 gi wire 6 swg 60 lt stay set ( 16 x 1800 mm ) 61 lt stay clamp with nut and bolt 62 stay wire 7 / 10 swg 63 lt stay insulator 64 dead end clamps with i hook ( insulated ) 65 suspension clamp with i hook 66 pole clamps with nut and bolt 67 holding clamp for round pole with nut and bolt 68 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 69 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 70 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 71 lt abc of 3x95+1x70+1x16 sq. mm 72 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 73 1x16 mm2 xlpe insulated al. cable for energising the street light 74 end cap for lt ab cable 75 pg clamps 76 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 77 pcc pole, 8.5 mtr. long 78 stone pad ( 300x300x75mm ) 79 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 80 gi wire 6 swg 81 lt stay set ( 16 x 1800 mm ) 82 lt stay clamp with nut and bolt 83 stay wire 7 / 10 swg 84 lt stay insulator 85 dead end clamps with i hook ( insulated ) 86 suspension clamp with i hook 87 pole clamps with nut and bolt 88 holding clamp for round pole with nut and bolt 89 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 90 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 91 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 92 lt abc of 3x120+1x95+1x16 sq. mm 93 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 94 1x16 mm2 xlpe insulated al. cable for energising the street light 95 end cap for lt ab cable 96 pg clamps 97 feeder bifurcation ( 11 kv line ) 98 11kv new line on 11 mtr. st pole with acsr dog conductor ( feeder bifurcation 11 kv line ) 99 11 kv polymer disc insulator b&s type 70 kn 100 disc fitting b&s type 70 kn 101 11 kv composite polymer pin insulator with nut and washers 102 11kv smc danger board with clamp, bolts & nuts 103 11kv smc number plate for clamp with n&b 104 11 kv stay set ( 16 x 1800 mm ) 105 11 kv stay clamp with nut and bolt 106 stay wire 7 / 10 swg 107 11 kv stay insulator 108 acsr dog conductor 109 p.g. clamp for acsr dog / raccoon 110 armour rod with ferrule for acsr dog / panther / raccoon helical performed 111 11 mtr. stp 112 13 mtr. stp 113 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 114 aluminium binding wire 6 swg 115 aluminium jointing sleeves 116 g.i. barbed wire 117 gi wire 6 swg 118 gi wire 8 swg 119 gi wire 16 swg 120 eye bolt 121 turn buckle 122 red oxide paint 123 aluminium paint 124 11kv e bracket with n&b 125 11kv `f bracket with n&b 126 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 127 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 128 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 129 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 130 cross arm holding clamp with nuts & bolts 131 v type cross arm for 11kv line, 100x50x6 mm, gi 132 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 133 gi guarding angle iron 75x75x6 mm 3010 mm long 134 stone pad ( 300x300x75mm ) 135 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 136 11 kv polymer disc insulator b&s type 70 kn 137 disc fitting b&s type 70 kn 138 11 kv composite polymer pin insulator with nut and washers 139 11kv smc danger board with clamp, bolts & nuts 140 11kv smc number plate for clamp with n&b 141 11 kv stay set ( 16 x 1800 mm ) 142 11 kv stay clamp with nut and bolt 143 stay wire 7 / 10 swg 144 11 kv stay insulator 145 acsr dog conductor 146 p.g. clamp for acsr dog / raccoon 147 armour rod with ferrule for acsr dog / panther / raccoon helical performed 148 pcc pole, 8.5 mtr. long 149 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 150 aluminium binding wire 6 swg 151 aluminium jointing sleeves 152 g.i. barbed wire 153 gi wire 6 swg 154 gi wire 8 swg 155 gi wire 16 swg 156 eye bolt 157 turn buckle 158 11kv e bracket with n&b 159 11kv `f bracket with n&b 160 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 161 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 162 cross arm holding clamp with nuts & bolts 163 v type cross arm for 11kv line, 100x50x6 mm, gi 164 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 165 gi guarding angle iron 75x75x6 mm 3010 mm long 166 stone pad ( 300x300x75mm ) 167 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 168 11 kv railway crossing 169 11kv 3x185 mm2xlpe cable 170 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 171 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 172 cable route marker 173 g.i. pipe 6 dia . 174 11 mtr. stp 175 stone pad ( 300x300x75mm ) 176 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 177 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 178 11 kv polymer disc insulator b&s type 70 kn 179 disc fitting b&s type 70 kn 180 p.g. clamp for acsr dog / raccoon 181 11kv smc number plate for clamp with n&b 182 11kv smc danger board with clamp, bolts & nuts 183 g.i. barbed wire 184 aluminium binding wire 6 swg 185 aluminium paint 186 red oxide paint 187 11 kvstay set ( 16 x 1800 mm ) 188 11 kv stay clamp with nut and bolt 189 stay wire 7 / 10 swg 190 11 kv stay insulator 191 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 192 gi wire 6 swg 193 nhai / state highway crossing 194 11kv 3x185 mm2xlpe cable 195 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 196 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 197 cable route marker 198 g.i. pipe 6 dia . 199 11 mtr. stp 200 stone pad ( 300x300x75mm ) 201 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 202 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 203 11 kv polymer disc insulator b&s type 70 kn 204 disc fitting b&s type 70 kn 205 p.g. clamp for acsr dog / raccoon 206 11kv smc number plate for clamp with n&b 207 11kv smc danger board with clamp, bolts & nuts 208 g.i. barbed wire 209 aluminium binding wire 6 swg 210 aluminium paint 211 red oxide paint 212 11 kv stay set ( 16 x 1800 mm ) 213 11 kv stay clamp with nut and bolt 214 stay wire 7 / 10 swg 215 11 kv stay insulator 216 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 217 gi wire 6 swg 218 augumentation / reconductoring of 33 kv overhead line with dog conductor 219 acsr dog conductor 220 pcc pole, 9.0 mtr. long 221 11 mtr. stp 222 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 223 gi wire 6 swg 224 33 kv composite polymer pin insulator with nut and washers 225 aluminium paint 226 red oxide paint 227 33kv smc danger board with clamp and n&b 228 33kv smc number plate with clampand n&b 229 stone pad ( 300x300x75mm ) 230 g.i. barbed wire 231 33kv e bracket with n&b 232 33kv f bracket with n&b 233 v type cross arm for 33kv line 100x50x6 mm, gi 234 cross arm holding clamp with nuts & bolts 235 33 kv polymer disc insulator b&s type 70 kn 236 disc fitting b&s type 70 kn 237 33 kv stay set 238 33 kv stay clamp with nut and bolt 239 stay wire 7 / 8 swg 240 33 kv stay insulator 241 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 242 acsr dog conductor 243 11 kv polymer disc insulator b&s type 70 kn 244 disc fitting b&s type 70 kn 245 11 kv composite polymer pin insulator with nut and washers 246 11kv smc danger board with clamp, bolts & nuts 247 11kv smc number plate for clamp with n&b 248 11 kv stay set ( 16 x 1800 mm ) 249 11 kv stay clamp with nut and bolt 250 stay wire 7 / 10 swg 251 11 kv stay insulator 252 p.g. clamp for acsr dog / raccoon 253 armour rod with ferrule for acsr dog / panther / raccoon helical performed 254 pcc pole, 8.5 mtr. long 255 11 mtr. stp 256 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 257 aluminium binding wire 6 swg 258 aluminium jointing sleeves 259 g.i. barbed wire 260 gi wire 6 swg 261 gi wire 8 swg 262 gi wire 16 swg 263 eye bolt 264 turn buckle 265 red oxide paint 266 aluminium paint 267 11kv `f bracket with n&b 268 cross arm holding clamp with nuts & bolts 269 v type cross arm for 11kv line, 100x50x6 mm, gi 270 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 271 stone pad ( 300x300x75mm ) 272 11 kv agriculture feeder segregation & feeder splitting due to overloading 273 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 274 acsr rabbit conductor 275 11kv polymer disc insulator t&c type 45 kn 276 disc fittings t&c type 45 kn 277 11 kv composite polymer pin insulator with nut and washers 278 11kv smc danger board with clamp, bolts & nuts 279 11kv smc number plate for clamp with n&b 280 11 kv stay set ( 16 x 1800 mm ) 281 11 kv stay clamp with nut and bolt 282 stay wire 7 / 10 swg 283 11 kv stay insulator 284 pg clamps 285 armour rod with ferrule for acsr dog / panther / raccoon helical performed 286 pcc pole, 8.5 mtr. long 287 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 288 aluminium binding wire 6 swg 289 aluminium jointing sleeves 290 g.i. barbed wire 291 gi wire 6 swg 292 gi wire 8 swg 293 gi wire 16 swg 294 eye bolt 295 turn buckle 296 11kv e bracket with n&b 297 11kv `f bracket with n&b 298 gi top channel 100x50x2240 mm. 299 clamp with nuts & bolts for 1300 mm long gi channel 300 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 301 gi top channel 100x50x6, 1525 mm long 302 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 303 cross arm holding clamp with nuts & bolts 304 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 305 v type cross arm for 11kv line, 65x65x6 mm, gi angle 306 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 307 stone pad ( 300x300x75mm ) 308 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 309 pcc pole, 8.5 mtr. long 310 stone pad ( 300x300x75mm ) 311 lt clamp with nut and bolt for pcc pole 312 lt shakle insulator 100x115 mm 313 bolts and nuts for shackle insulators 314 acsr rabbit conductor 315 aluminium jointing sleeves 316 aluminium binding wire 6 swg 317 earth wire clamp 318 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 319 gi wire 6 swg 320 lt stay set ( 16 x 1800 mm ) 321 lt stay clamp with nut and bolt 322 stay wire 7 / 10 swg 323 lt stay insulator 324 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 325 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 326 pcc pole, 8.5 mtr. long 327 stone pad ( 300x300x75mm ) 328 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 329 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 330 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 331 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 332 gi channel 125x65x6, 1300mm ( tee off ) 333 clamp with nuts & bolts for 1300 mm long gi channel 334 11kv polymer disc insulator t&c type 45 kn 335 disc fittings t&c type 45 kn 336 11 kv composite polymer pin insulator with nut and washers 337 11kv tpmo complete set 338 11kv do fuse set ( 3 phase ) 339 11kv lightening arrestor 340 g.i. barbed wire 341 11kv smc danger board with clamp, bolts & nuts 342 deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 343 lt stay set ( 16 x 1800 mm ) 344 lt stay clamp with nut and bolt 345 stay wire 7 / 10 swg 346 lt stay insulator 347 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 348 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 349 lt pvc cable3.5x150 / 70sq.mm. 350 acsr weasel conductor 351 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 352 gi wire 6 swg 353 gi strip 25x3 mm 354 gi angle 100x50x2028mm ( fordistribution box ) ) 355 al. crimping lugs 150 sq.mm. 356 al. crimping lugs 70 sq.mm. 357 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 358 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 359 11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 360 pcc pole, 8.5 mtr. long 361 stone pad ( 300x300x75mm ) 362 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 363 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 364 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 365 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 366 gi channel 125x65x6, 1300mm ( tee off ) 367 clamp with nuts & bolts for 1300 mm long gi channel 368 11kv polymer disc insulator t&c type 45 kn 369 disc fittings t&c type 45 kn 370 11 kv composite polymer pin insulator with nut and washers 371 11kv tpmo complete set 372 11kv do fuse set ( 3 phase ) 373 11kv lightening arrestor 374 g.i. barbed wire 375 11kv smc danger board with clamp, bolts & nuts 376 deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 377 lt stay set ( 16 x 1800 mm ) 378 lt stay clamp with nut and bolt 379 stay wire 7 / 10 swg 380 lt stay insulator 381 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 382 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 383 lt pvc cable3.5x70 / 35sq.mm. 384 acsr weasel conductor 385 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 386 gi wire 6 swg 387 gi strip 25x3 mm 388 gi angle 100x50x2028mm ( fordistribution box ) ) 389 al. crimping lugs 70 sq.mm. 390 al. crimping lugs 35 sq.mm. 391 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 392 installation of 11 kv outgoing vcb for feeder segreration 393 11kv outgoing ctr 400 / 200 / 5a 350 mva 394 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 395 11kv 3x185 mm2xlpe cable 396 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 397 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 398 11 mtr. stp 399 gi top channel 100x50x2240 mm. 400 stone pad ( 300x300x75mm ) 401 11 kv polymer disc insulator b&s type 70 kn 402 disc fitting b&s type 70 kn 403 11 kv composite polymer pin insulator with nut and washers 404 p.g. clamp for acsr dog / raccoon 405 11kv e bracket with n&b 406 11kv smc number plate for clamp with n&b 407 11kv smc danger board with clamp, bolts & nuts 408 gi channel 125x65x2028 mm long ( dropper for fuse set ) 409 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 410 11kv tpmo complete set 411 11kv do fuse set ( 3 phase ) 412 11kv lightening arrestor 413 g.i. barbed wire 414 aluminium binding wire 6 swg 415 aluminium paint 416 red oxide paint 417 11 kv stay set ( 16 x 1800 mm ) 418 11 kv stay clamp with nut and bolt 419 stay wire 7 / 10 swg 420 11 kv stay insulator 421 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 422 gi strip 50x6 mm 423 gi wire 6 swg 424 g.i. pipe 6 dia . 425 11 kv railway crossing 426 11kv 3x185 mm2xlpe cable 427 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 428 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 429 cable route marker 430 g.i. pipe 6 dia . 431 11 mtr. stp 432 stone pad ( 300x300x75mm ) 433 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 434 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 435 11 kv polymer disc insulator b&s type 70 kn 436 disc fitting b&s type 70 kn 437 p.g. clamp for acsr dog / raccoon 438 11kv smc number plate for clamp with n&b 439 11kv smc danger board with clamp, bolts & nuts 440 g.i. barbed wire 441 aluminium binding wire 6 swg 442 aluminium paint 443 red oxide paint 444 11 kvstay set ( 16 x 1800 mm ) 445 11 kv stay clamp with nut and bolt 446 stay wire 7 / 10 swg 447 11 kv stay insulator 448 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 449 gi wire 6 swg 450 requirement of extra ab cable for new additional ckt at dts 451 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 452 pcc pole, 8.5 mtr. long 453 11 mtr. stp 454 stone pad ( 300x300x75mm ) 455 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 456 gi wire 6 swg 457 lt stay set ( 16 x 1800 mm ) 458 lt stay clamp with nut and bolt 459 stay wire 7 / 10 swg 460 lt stay insulator 461 dead end clamps with i hook ( insulated ) 462 suspension clamp with i hook 463 pole clamps with nut and bolt 464 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 465 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 466 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 467 lt abc of 3x50+1x35+1x16 sq. mm 468 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 469 end cap for lt ab cable 470 pg clamps 471 1x16 mm2 xlpe insulated al. cable for energising the street light 472 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 473 pcc pole, 8.5 mtr. long 474 11 mtr. stp 475 stone pad ( 300x300x75mm ) 476 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 477 gi wire 6 swg 478 lt stay set ( 16 x 1800 mm ) 479 lt stay clamp with nut and bolt 480 stay wire 7 / 10 swg 481 lt stay insulator 482 dead end clamps with i hook ( insulated ) 483 suspension clamp with i hook 484 pole clamps with nut and bolt 485 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 486 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 487 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 488 lt abc of 3x95+1x70+1x16 sq. mm 489 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 490 end cap for lt ab cable 491 pg clamps 492 1x16 mm2 xlpe insulated al. cable for energising the street light 493 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 494 pcc pole, 8.5 mtr. long 495 11 mtr. stp 496 stone pad ( 300x300x75mm ) 497 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 498 gi wire 6 swg 499 lt stay set ( 16 x 1800 mm ) 500 lt stay clamp with nut and bolt 501 stay wire 7 / 10 swg 502 lt stay insulator 503 dead end clamps with i hook ( insulated ) 504 suspension clamp with i hook 505 pole clamps with nut and bolt 506 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 507 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 508 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 509 lt abc of 3x120+1x95+1x16 sq. mm 510 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 511 end cap for lt ab cable 512 pg clamps 513 1x16 mm2 xlpe insulated al. cable for energising the street light 514 additional items that may be required for completion of work 515 3x120 sq. mm 11 kv ab cable 516 11kv polymer disc insulator with fitting for 11 kvabc 517 11kv polymer disc insulators with i hook 518 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 519 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 520 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 521 33kv 3x300 mm2xlpe cable 522 lt xlpe insulated unarmoured 1x50 sq. mm. cable 523 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 524 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 525 loop guard complete, 3 phase 526 spacers lt pvc 527 mid span jointing sleeves ( 95 sq. mm ) 528 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 529 supply of on / off switch for street light connections 530 height raising channel 100x50, 2240 mm long 531 back clamp for height raising channel holding clamps with bolts & nuts 532 cable jointing kit straight through ( 3x185 sqmm ) 533 cable jointing kit straight through ( 3x300sqmm ) 534 extra prefabricated gi items like clamp, channel, angle with nut & bolt 535 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 536 erection of pcc pole, 8.5 mtr. long 537 fixing of bolts and nuts for shackle insulators 538 fixing of lt shakle insulator 100x115 mm 539 fixing of d straps 540 stringing of lt xlpe armoured 3.5x50 sq. mm. cable 541 fixing of mid span jointing sleeves ( 120 sq. mm ) 542 fixing of insulating piercing connector ( 50 150 sq.mm ) 543 fixing of insulation mastic tape ( 2inc x 10 feet ) . 544 fixing of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 545 fixing of single phase deep drawn distribution box with clamps and suitable lock and key arrangment 546 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 547 1x16 mm2 xlpe insulated al. cable for energising the street light 548 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 549 gi wire 6 swg 550 erection of lt stay set ( 16 x 1800 mm ) 551 fixing of lt stay clamp with nut and bolt 552 erection of stay wire 7 / 10 swg 553 fixing of lt stay insulator 554 concreting of stay set ( 16x 1800 mm ) 555 stone pad ( 300x300x75mm ) 556 fixing of lt clamp with nut and bolt for pcc pole 557 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 558 concreting of pole / support ( 0.268 cu.m. ) 559 fixing of angle for vertical arm l50x50x6 ( type a ) 560 fixing of angle for vertical arm l50x50x6 ( type b ) 561 fixing of top clamp for vertical arm ( type a ) 562 fixing of top clamp for vertical arm ( type b ) 563 fixing of bottom clamp for vertical arm ( type a ) 564 fixing of bottom clamp for vertical arm ( type b ) 565 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 566 stringing of pvc 2c x 6 sq.mm. armoured cable for service connection 567 dismanting of old line service cable and connection of new armoured cable 568 fixing of polycarbonated box for single phase consumer 569 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 570 stringing of pvc 4c x 16 sq.mm. armoured cable for service connection 571 dismanting of old line service cable and connection of new armoured cable 572 fixing of polycarbonated box for three phase consumer 573 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 574 erection of pcc pole, 8.5 mtr. long 575 stone pad ( 300x300x75mm ) 576 concreting of pole / support ( 0.268 cu.m. ) 577 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 578 gi wire 6 swg 579 erection of lt stay set ( 16 x 1800 mm ) 580 fixing of lt stay clamp with nut and bolt 581 erection of stay wire 7 / 10 swg 582 fixing of lt stay insulator 583 concreting of stay set ( 16x 1800 mm ) 584 fixing of dead end clamps with i hook ( insulated ) 585 fixing of suspension clamp with i hook 586 fixing of pole clamps with nut and bolt 587 fixing of holding clamp for round pole with nut and bolt 588 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 589 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 590 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 591 stringing of lt abc of 3x50+1x35+1x16 sq. mm 592 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 593 1x16 mm2 xlpe insulated al. cable for energising the street light 594 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 595 fixing of end cap for lt ab cable 596 fixing of pg clamps 597 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 598 erection of pcc pole, 8.5 mtr. long 599 stone pad ( 300x300x75mm ) 600 concreting of pole / support ( 0.268 cu.m. ) 601 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 602 gi wire 6 swg 603 erection of lt stay set ( 16 x 1800 mm ) 604 fixing of lt stay clamp with nut and bolt 605 erection of stay wire 7 / 10 swg 606 fixing of lt stay insulator 607 concreting of stay set ( 16x 1800 mm ) 608 dead end clamps with i hook ( insulated ) 609 fixing of suspension clamp with i hook 610 fixing of pole clamps with nut and bolt 611 holding clamp for round pole with nut and bolt 612 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 613 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 614 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 615 stringing of lt abc of 3x95+1x70+1x16 sq. mm 616 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 617 1x16 mm2 xlpe insulated al. cable for energising the street light 618 end cap for lt ab cable 619 fixing of pg clamps 620 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 621 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 622 erection of pcc pole, 8.5 mtr. long 623 stone pad ( 300x300x75mm ) 624 concreting of pole / support ( 0.268 cu.m. ) 625 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 626 gi wire 6 swg 627 erection of lt stay set ( 16 x 1800 mm ) 628 fixing of lt stay clamp with nut and bolt 629 erection of stay wire 7 / 10 swg 630 fixing of lt stay insulator 631 concreting of stay set ( 16x 1800 mm ) 632 dead end clamps with i hook ( insulated ) 633 fixing of suspension clamp with i hook 634 fixing of pole clamps with nut and bolt 635 holding clamp for round pole with nut and bolt 636 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 637 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 638 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 639 stringing of lt abc of 3x120+1x95+1x16 sq. mm 640 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 641 1x16 mm2 xlpe insulated al. cable for energising the street light 642 end cap for lt ab cable 643 fixing of pg clamps 644 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 645 feeder bifurcation ( 11 kv line ) 646 11kv new line on 11 mtr. st pole with acsr dog conductor 647 erection of 11 kv polymer disc insulator b&s type 70 kn 648 erection of disc fitting b&s type 70 kn 649 erection of 11 kv composite polymer pin insulator with nut and washers 650 fixing of 11kv smc danger board with clamp, bolts & nuts 651 fixing of 11kv smc number plate for clamp with n&b 652 erection of 11 kv stay set ( 16 x 1800 mm ) 653 fixing of 11 kv stay clamp with nut and bolt 654 erection of stay wire 7 / 10 swg 655 fixing of 11 kv stay insulator 656 concreting of stay set ( 16x 1800 mm ) 657 stringing of acsr dog conductor 658 fixing of p.g. clamp for acsr dog / raccoon 659 armour rod with ferrule for acsr dog / panther / raccoon helical performed 660 erection of 11 mtr. stp 661 erection of 13 mtr. stp 662 concreting of pole / support ( 0.44 cu.m. ) 663 concreting of pole ( 0.64 cu.m. ) 664 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 665 aluminium binding wire 6 swg 666 aluminium jointing sleeves 667 g.i. barbed wire 668 gi wire 6 swg 669 gi wire 8 swg 670 gi wire 16 swg 671 eye bolt 672 turn buckle 673 painting of st pole with red oxide paint 674 painting of st pole with aluminium paint 675 erection of 11kv e bracket with n&b 676 erection of 11kv `f bracket with n&b 677 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 678 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 679 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 680 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 681 cross arm holding clamp with nuts & bolts 682 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 683 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 684 gi guarding angle iron 75x75x6 mm 3010 mm long 685 tree cutting compensation 686 stone pad ( 300x300x75mm ) 687 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 688 erection of 11 kv polymer disc insulator b&s type 70 kn 689 erection of disc fitting b&s type 70 kn 690 erection of 11 kv composite polymer pin insulator with nut and washers 691 fixing of 11kv smc danger board with clamp, bolts & nuts 692 fixing of 11kv smc number plate for clamp with n&b 693 erection of 11 kv stay set ( 16 x 1800 mm ) 694 fixing of 11 kv stay clamp with nut and bolt 695 erection of stay wire 7 / 10 swg 696 fixing of 11 kv stay insulator 697 concreting of stay set ( 16x 1800 mm ) 698 stringing of acsr dog conductor 699 fixing of p.g. clamp for acsr dog / raccoon 700 armour rod with ferrule for acsr dog / panther / raccoon helical performed 701 erection of pcc pole, 8.5 mtr. long 702 concreting of pole / support ( 0.268 cu.m. ) 703 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 704 aluminium binding wire 6 swg 705 aluminium jointing sleeves 706 g.i. barbed wire 707 gi wire 6 swg 708 gi wire 8 swg 709 gi wire 16 swg 710 eye bolt 711 turn buckle 712 erection of 11kv e bracket with n&b 713 erection of 11kv `f bracket with n&b 714 gi top channel 125x65mm, 3200 mm with clamp, bolts, nuts and washers 715 gi angle 65x65x6mm, 4300 mm long bracing with 4 clamps, bolts, nuts and washers 716 cross arm holding clamp with nuts & bolts 717 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 718 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 719 gi guarding angle iron 75x75x6 mm 3010 mm long 720 tree cutting compensation 721 stone pad ( 300x300x75mm ) 722 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 723 11 kv railway crossing 724 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 725 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 726 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 727 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 728 cable route marker 729 g.i. pipe 6 dia . 730 erection of 11 mtr. stp 731 stone pad ( 300x300x75mm ) 732 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 733 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 734 erection of 11 kv polymer disc insulator b&s type 70 kn 735 erection of disc fitting b&s type 70 kn 736 fixing of p.g. clamp for acsr dog / raccoon 737 fixing of 11kv smc number plate for clamp with n&b 738 fixing of 11kv smc danger board with clamp, bolts & nuts 739 g.i. barbed wire 740 aluminium binding wire 6 swg 741 painting of st pole with aluminium paint 742 painting of st pole with red oxide paint 743 erection of 11 kvstay set ( 16 x 1800 mm ) 744 fixing of 11 kv stay clamp with nut and bolt 745 erection of stay wire 7 / 10 swg 746 fixing of 11 kv stay insulator 747 concreting of stay set ( 16x 1800 mm ) 748 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 749 gi wire 6 swg 750 concreting of pole / support ( 0.44 cu.m. ) 751 railway crossing documentation, land and approval fee etc. 752 nhai / state highway crossing 753 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 754 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 755 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 756 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 757 cable route marker 758 g.i. pipe 6 dia . 759 erection of 11 mtr. stp 760 stone pad ( 300x300x75mm ) 761 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 762 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 763 erection of 11 kv polymer disc insulator b&s type 70 kn 764 disc fitting b&s type 70 kn 765 fixing of p.g. clamp for acsr dog / raccoon 766 fixing of 11kv smc number plate for clamp with n&b 767 fixing of 11kv smc danger board with clamp, bolts & nuts 768 g.i. barbed wire 769 aluminium binding wire 6 swg 770 painting of st pole with aluminium paint 771 painting of st pole with red oxide paint 772 erection of 11 kv stay set ( 16 x 1800 mm ) 773 fixing of 11 kv stay clamp with nut and bolt 774 erection of stay wire 7 / 10 swg 775 fixing of 11 kv stay insulator 776 concreting of stay set ( 16x 1800 mm ) 777 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 778 gi wire 6 swg 779 concreting of pole / support ( 0.44 cu.m. ) 780 nhai / state highway crossing documentation, land charges and approval fee etc. 781 road restoration charges 782 augumentation / reconductoring of 33 kv overhead line with dog conductor 783 stringing of acsr dog conductor 784 erection of pcc pole, 9.0 mtr. long 785 erection of 11 mtr. stp 786 concreting of pole / support ( 0.286 cu.m. ) 787 concreting of pole / support ( 0.44 cu.m. ) 788 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 789 gi wire 6 swg 790 erection of 33 kv composite polymer pin insulator with nut and washers 791 painting of st pole with aluminium paint 792 painting of st pole with red oxide paint 793 fixing of 33kv smc danger board with clamp and n&b 794 fixing of 33kv smc number plate with clampand n&b 795 stone pad ( 300x300x75mm ) 796 g.i. barbed wire 797 erection of 33kv e bracket with n&b 798 erection of 33kv f bracket with n&b 799 erection of v type cross arm for 33kv line 100x50x6 mm, gi 800 cross arm holding clamp with nuts & bolts 801 erection of 33 kv polymer disc insulator b&s type 70 kn 802 disc fitting b&s type 70 kn 803 erection of 33 kv stay set 804 fixing of 33 kv stay clamp with nut and bolt 805 erection of stay wire 7 / 8 swg 806 fixing of 33 kv stay insulator 807 concreting of 33 kv stay set 808 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 809 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 810 stringing of acsr dog conductor 811 erection of 11 kv polymer disc insulator b&s type 70 kn 812 disc fitting b&s type 70 kn 813 erection of 11 kv composite polymer pin insulator with nut and washers 814 fixing of 11kv smc danger board with clamp, bolts & nuts 815 fixing of 11kv smc number plate for clamp with n&b 816 erection of 11 kv stay set ( 16 x 1800 mm ) 817 fixing of 11 kv stay clamp with nut and bolt 818 erection of stay wire 7 / 10 swg 819 fixing of 11 kv stay insulator 820 concreting of stay set ( 16x 1800 mm ) 821 fixing of p.g. clamp for acsr dog / raccoon 822 armour rod with ferrule for acsr dog / panther / raccoon helical performed 823 erection of pcc pole, 8.5 mtr. long 824 erection of 11 mtr. stp 825 concreting of pole / support ( 0.268 cu.m. ) 826 concreting of pole / support ( 0.44 cu.m. ) 827 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 828 aluminium binding wire 6 swg 829 aluminium jointing sleeves 830 g.i. barbed wire 831 gi wire 6 swg 832 gi wire 8 swg 833 gi wire 16 swg 834 eye bolt 835 turn buckle 836 painting of st pole with red oxide paint 837 painting of st pole with aluminium paint 838 erection of 11kv `f bracket with n&b 839 cross arm holding clamp with nuts & bolts 840 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 841 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 842 stone pad ( 300x300x75mm ) 843 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 844 11 kv agriculture feeder segregation & feeder splitting due to overloading 845 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 846 stringing of acsr rabbit conductor 847 erection of 11kv polymer disc insulator t&c type 45 kn 848 disc fittings t&c type 45 kn 849 erection of 11 kv composite polymer pin insulator with nut and washers 850 fixing of 11kv smc danger board with clamp, bolts & nuts 851 fixing of 11kv smc number plate for clamp with n&b 852 erection of 11 kv stay set ( 16 x 1800 mm ) 853 fixing of 11 kv stay clamp with nut and bolt 854 erection of stay wire 7 / 10 swg 855 fixing of 11 kv stay insulator 856 concreting of stay set ( 16x 1800 mm ) 857 fixing of pg clamps 858 armour rod with ferrule for acsr dog / panther / raccoon helical performed 859 erection of pcc pole, 8.5 mtr. long 860 concreting of pole / support ( 0.268 cu.m. ) 861 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 862 aluminium binding wire 6 swg 863 aluminium jointing sleeves 864 g.i. barbed wire 865 gi wire 6 swg 866 gi wire 8 swg 867 gi wire 16 swg 868 eye bolt 869 turn buckle 870 erection of 11kv e bracket with n&b 871 erection of 11kv `f bracket with n&b 872 gi top channel 100x50x2240 mm. 873 clamp with nuts & bolts for 1300 mm long gi channel 874 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 875 gi top channel 100x50x6, 1525 mm long 876 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 877 cross arm holding clamp with nuts & bolts 878 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 879 erection of v type cross arm for 11kv line, 65x65x6 mm, gi angle 880 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 881 tree cutting compensation 882 stone pad ( 300x300x75mm ) 883 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 884 erection of pcc pole, 8.5 mtr. long 885 stone pad ( 300x300x75mm ) 886 lt clamp with nut and bolt for pcc pole 887 lt shakle insulator 100x115 mm 888 bolts and nuts for shackle insulators 889 concreting of pole / support ( 0.268 cu.m. ) 890 stringing of acsr rabbit conductor 891 aluminium jointing sleeves 892 aluminium binding wire 6 swg 893 earth wire clamp 894 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 895 gi wire 6 swg 896 erection of lt stay set ( 16 x 1800 mm ) 897 fixing of lt stay clamp with nut and bolt 898 erection of stay wire 7 / 10 swg 899 fixing of lt stay insulator 900 concreting of stay set ( 16x 1800 mm ) 901 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 902 installation of 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 903 erection of pcc pole, 8.5 mtr. long 904 stone pad ( 300x300x75mm ) 905 concreting of pole / support ( 0.268 cu.m. ) 906 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 907 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 908 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 909 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 910 gi channel 125x65x6, 1300mm ( tee off ) 911 clamp with nuts & bolts for 1300 mm long gi channel 912 erection of 11kv polymer disc insulator t&c type 45 kn 913 disc fittings t&c type 45 kn 914 erection of 11 kv composite polymer pin insulator with nut and washers 915 erection of 11kv tpmo complete set 916 erection of 11kv do fuse set ( 3 phase ) 917 erection of 11kv lightening arrestor 918 g.i. barbed wire 919 fixing of 11kv smc danger board with clamp, bolts & nuts 920 fixing of deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 921 erection of lt stay set ( 16 x 1800 mm ) 922 fixing of lt stay clamp with nut and bolt 923 erection of stay wire 7 / 10 swg 924 fixing of lt stay insulator 925 concreting of stay set ( 16x 1800 mm ) 926 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 927 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 928 lt pvc cable3.5x150 / 70sq.mm. 929 acsr weasel conductor 930 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 931 gi wire 6 swg 932 gi strip 25x3 mm 933 gi angle 100x50x2028mm ( fordistribution box ) ) 934 al. crimping lugs 150 sq.mm. 935 al. crimping lugs 70 sq.mm. 936 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 937 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 938 installation of11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 939 erection of pcc pole, 8.5 mtr. long 940 stone pad ( 300x300x75mm ) 941 concreting of pole / support ( 0.268 cu.m. ) 942 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 943 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 944 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 945 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 946 gi channel 125x65x6, 1300mm ( tee off ) 947 clamp with nuts & bolts for 1300 mm long gi channel 948 erection of 11kv polymer disc insulator t&c type 45 kn 949 disc fittings t&c type 45 kn 950 erection of 11 kv composite polymer pin insulator with nut and washers 951 erection of 11kv tpmo complete set 952 erection of 11kv do fuse set ( 3 phase ) 953 erection of 11kv lightening arrestor 954 g.i. barbed wire 955 fixing of 11kv smc danger board with clamp, bolts & nuts 956 fixing of deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 957 erection of lt stay set ( 16 x 1800 mm ) 958 fixing of lt stay clamp with nut and bolt 959 erection of stay wire 7 / 10 swg 960 fixing of lt stay insulator 961 concreting of stay set ( 16x 1800 mm ) 962 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 963 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 964 lt pvc cable3.5x70 / 35sq.mm. 965 acsr weasel conductor 966 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 967 gi wire 6 swg 968 gi strip 25x3 mm 969 gi angle 100x50x2028mm ( fordistribution box ) ) 970 al. crimping lugs 70 sq.mm. 971 al. crimping lugs 35 sq.mm. 972 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 973 installation of 11 kv outgoing vcb for feeder segreration 974 installation of 11kv outgoing ctr 400 / 200 / 5a 350 mva 975 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 976 11kv 3x185 mm2xlpe cable 977 laying of 11 kv cable including cost of sand & bricks 978 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 979 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 980 erection of 11 mtr. stp 981 gi top channel 100x50x2240 mm. 982 stone pad ( 300x300x75mm ) 983 erection of 11 kv polymer disc insulator b&s type 70 kn 984 disc fitting b&s type 70 kn 985 erection of 11 kv composite polymer pin insulator with nut and washers 986 fixing of p.g. clamp for acsr dog / raccoon 987 erection of 11kv e bracket with n&b 988 fixing of 11kv smc number plate for clamp with n&b 989 fixing of 11kv smc danger board with clamp, bolts & nuts 990 gi channel 125x65x2028 mm long ( dropper for fuse set ) 991 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 992 erection of 11kv tpmo complete set 993 erection of 11kv do fuse set ( 3 phase ) 994 erection of 11kv lightening arrestor 995 g.i. barbed wire 996 aluminium binding wire 6 swg 997 painting of st pole with aluminium paint 998 painting of st pole with red oxide paint 999 erection of 11 kv stay set ( 16 x 1800 mm ) 1000 fixing of 11 kv stay clamp with nut and bolt 1001 erection of stay wire 7 / 10 swg 1002 fixing of 11 kv stay insulator 1003 concreting of stay set ( 16x 1800 mm ) 1004 concreting of pole / support ( 0.44 cu.m. ) 1005 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1006 gi strip 50x6 mm 1007 gi wire 6 swg 1008 g.i. pipe 6 dia . 1009 control room extension 1010 extension of existing substationcontrol room building. ( as per annexure attached in tender documents. ) 1011 11 kv railway crossing 1012 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1013 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1014 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1015 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1016 cable route marker 1017 g.i. pipe 6 dia . 1018 erection of 11 mtr. stp 1019 stone pad ( 300x300x75mm ) 1020 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1021 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1022 erection of 11 kv polymer disc insulator b&s type 70 kn 1023 disc fitting b&s type 70 kn 1024 fixing of p.g. clamp for acsr dog / raccoon 1025 fixing of 11kv smc number plate for clamp with n&b 1026 fixing of 11kv smc danger board with clamp, bolts & nuts 1027 g.i. barbed wire 1028 aluminium binding wire 6 swg 1029 painting of st pole with aluminium paint 1030 painting of st pole with red oxide paint 1031 erection of 11 kvstay set ( 16 x 1800 mm ) 1032 fixing of 11 kv stay clamp with nut and bolt 1033 erection of stay wire 7 / 10 swg 1034 fixing of 11 kv stay insulator 1035 concreting of stay set ( 16x 1800 mm ) 1036 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1037 gi wire 6 swg 1038 concreting of pole / support ( 0.44 cu.m. ) 1039 railway crossing documentation, land and approval fee etc. 1040 requirement of extra ab cable for new additional ckt at dts 1041 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 1042 erection of pcc pole, 8.5 mtr. long 1043 erection of 11 mtr. stp 1044 stone pad ( 300x300x75mm ) 1045 concreting of pole / support ( 0.268 cu.m. ) 1046 concreting of pole / support ( 0.44 cu.m. ) 1047 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1048 gi wire 6 swg 1049 erection of lt stay set ( 16 x 1800 mm ) 1050 fixing of lt stay clamp with nut and bolt 1051 erection of stay wire 7 / 10 swg 1052 fixing of lt stay insulator 1053 concreting of stay set ( 16x 1800 mm ) 1054 dead end clamps with i hook ( insulated ) 1055 fixing of suspension clamp with i hook 1056 fixing of pole clamps with nut and bolt 1057 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1058 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1059 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1060 stringing of lt abc of 3x50+1x35+1x16 sq. mm 1061 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1062 end cap for lt ab cable 1063 fixing of pg clamps 1064 1x16 mm2 xlpe insulated al. cable for energising the street light 1065 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 1066 erection of pcc pole, 8.5 mtr. long 1067 erection of 11 mtr. stp 1068 stone pad ( 300x300x75mm ) 1069 concreting of pole / support ( 0.268 cu.m. ) 1070 concreting of pole / support ( 0.44 cu.m. ) 1071 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1072 gi wire 6 swg 1073 erection of lt stay set ( 16 x 1800 mm ) 1074 fixing of lt stay clamp with nut and bolt 1075 erection of stay wire 7 / 10 swg 1076 fixing of lt stay insulator 1077 concreting of stay set ( 16x 1800 mm ) 1078 dead end clamps with i hook ( insulated ) 1079 fixing of suspension clamp with i hook 1080 fixing of pole clamps with nut and bolt 1081 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1082 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1083 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1084 stringing of lt abc of 3x95+1x70+1x16 sq. mm 1085 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1086 end cap for lt ab cable 1087 fixing of pg clamps 1088 1x16 mm2 xlpe insulated al. cable for energising the street light 1089 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 1090 erection of pcc pole, 8.5 mtr. long 1091 erection of 11 mtr. stp 1092 stone pad ( 300x300x75mm ) 1093 concreting of pole / support ( 0.268 cu.m. ) 1094 concreting of pole / support ( 0.44 cu.m. ) 1095 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1096 gi wire 6 swg 1097 erection of lt stay set ( 16 x 1800 mm ) 1098 fixing of lt stay clamp with nut and bolt 1099 erection of stay wire 7 / 10 swg 1100 fixing of lt stay insulator 1101 concreting of stay set ( 16x 1800 mm ) 1102 dead end clamps with i hook ( insulated ) 1103 fixing of suspension clamp with i hook 1104 fixing of pole clamps with nut and bolt 1105 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1106 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1107 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1108 stringing of lt abc of 3x120+1x95+1x16 sq. mm 1109 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1110 end cap for lt ab cable 1111 fixing of pg clamps 1112 1x16 mm2 xlpe insulated al. cable for energising the street light 1113 additional items that may be required for completion of work 1114 3x120 sq. mm 11 kv ab cable 1115 11kv polymer disc insulator with fitting for 11 kvabc 1116 11kv polymer disc insulators with i hook 1117 erection & concreting of extra stud pole complete with clamps, 1118 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 1119 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 1120 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 1121 lt xlpe insulated unarmoured 1x50 sq. mm. cable 1122 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 1123 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 1124 laying of 3x300 sq. mm. 33 kv xlpe insulated cable underground in hdpe pipe or trenches ( for railway / road crossing ) 1125 drilling & laying of ht underground cable using hdd method without using hdpe pipe 1126 loop guard complete, 3 phase 1127 spacers lt pvc 1128 mid span jointing sleeves ( 95 sq. mm ) 1129 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 1130 fixing of on / off switch for street light connections 1131 mounting of cable on dp structure ( including loop and riser ) 1132 height raising channel 100x50, 2240 mm long 1133 back clamp for height raising channel holding clamps with bolts & nuts 1134 cable jointing kit straight through ( 3x185 sqmm ) 1135 cable jointing kit straight through ( 3x300sqmm ) 1136 extra prefabricated gi items like clamp, channel, angle with nut & bolt...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32106623 development of distribution infrastructure work for loss reduction at district moradabad, bijnor and rampur in psvvnl under revamped reforms based and results linked, distribution sector scheme 1 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 2 pcc pole, 8.5 mtr. long 3 bolts and nuts for shackle insulators 4 lt shakle insulator 100x115 mm 5 d straps 6 lt xlpe armoured 3.5x50 sq. mm. cable 7 mid span jointing sleeves ( 50 sq. mm ) 8 insulating piercing connector ( 50 150 sq.mm ) 9 insulation mastic tape ( 2inc x 10 feet ) . 10 supply of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 11 supply of single of phase deep drawn distribution box with clamps and suitable lock and key arrangment 12 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 13 1x16 mm2 xlpe insulated al. cable for energising the street light 14 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 15 gi wire 6 swg 16 lt stay set ( 16 x 1800 mm ) 17 lt stay clamp with nut and bolt 18 stay wire 7 / 10 swg 19 lt stay insulator 20 stone pad ( 300x300x75mm ) 21 lt clamp with nut and bolt for pcc pole 22 angle for vertical arm l50x50x6 ( type a ) 23 angle for vertical arm l50x50x6 ( type b ) 24 top clamp for vertical arm ( type a ) 25 top clamp for vertical arm ( type b ) 26 bottom clamp for vertical arm ( type a ) 27 bottom clamp for vertical arm ( type b ) 28 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 29 pvc 2c x 6 sq.mm. armoured cable for service connection 30 polycarbonated box for single phase consumer 31 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 32 pvc 4c x 16 sq.mm. armoured cable for service connection 33 polycarbonated box for three phase consumer 34 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 35 pcc pole, 8.5 mtr. long 36 stone pad ( 300x300x75mm ) 37 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 38 gi wire 6 swg 39 lt stay set ( 16 x 1800 mm ) 40 lt stay clamp with nut and bolt 41 stay wire 7 / 10 swg 42 lt stay insulator 43 dead end clamps with i hook ( insulated ) 44 suspension clamp with i hook 45 pole clamps with nut and bolt 46 holding clamp for round pole with nut and bolt 47 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 48 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 49 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 50 lt abc of 3x50+1x35+1x16 sq. mm 51 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 52 1x16 mm2 xlpe insulated al. cable for energising the street light 53 end cap for lt ab cable 54 pg clamps 55 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 56 pcc pole, 8.5 mtr. long 57 stone pad ( 300x300x75mm ) 58 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 59 gi wire 6 swg 60 lt stay set ( 16 x 1800 mm ) 61 lt stay clamp with nut and bolt 62 stay wire 7 / 10 swg 63 lt stay insulator 64 dead end clamps with i hook ( insulated ) 65 suspension clamp with i hook 66 pole clamps with nut and bolt 67 holding clamp for round pole with nut and bolt 68 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 69 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 70 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 71 lt abc of 3x95+1x70+1x16 sq. mm 72 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 73 1x16 mm2 xlpe insulated al. cable for energising the street light 74 end cap for lt ab cable 75 pg clamps 76 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 77 pcc pole, 8.5 mtr. long 78 stone pad ( 300x300x75mm ) 79 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 80 gi wire 6 swg 81 lt stay set ( 16 x 1800 mm ) 82 lt stay clamp with nut and bolt 83 stay wire 7 / 10 swg 84 lt stay insulator 85 dead end clamps with i hook ( insulated ) 86 suspension clamp with i hook 87 pole clamps with nut and bolt 88 holding clamp for round pole with nut and bolt 89 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 90 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 91 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 92 lt abc of 3x120+1x95+1x16 sq. mm 93 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 94 1x16 mm2 xlpe insulated al. cable for energising the street light 95 end cap for lt ab cable 96 pg clamps 97 feeder bifurcation ( 11 kv line ) 98 11kv new line on 11 mtr. st pole with acsr dog conductor ( feeder bifurcation 11 kv line ) 99 11 kv polymer disc insulator b&s type 70 kn 100 disc fitting b&s type 70 kn 101 11 kv composite polymer pin insulator with nut and washers 102 11kv smc danger board with clamp, bolts & nuts 103 11kv smc number plate for clamp with n&b 104 11 kv stay set ( 16 x 1800 mm ) 105 11 kv stay clamp with nut and bolt 106 stay wire 7 / 10 swg 107 11 kv stay insulator 108 acsr dog conductor 109 p.g. clamp for acsr dog / raccoon 110 armour rod with ferrule for acsr dog / panther / raccoon helical performed 111 11 mtr. stp 112 13 mtr. stp 113 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 114 aluminium binding wire 6 swg 115 aluminium jointing sleeves 116 g.i. barbed wire 117 gi wire 6 swg 118 gi wire 8 swg 119 gi wire 16 swg 120 eye bolt 121 turn buckle 122 red oxide paint 123 aluminium paint 124 11kv e bracket with n&b 125 11kv `f bracket with n&b 126 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 127 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 128 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 129 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 130 cross arm holding clamp with nuts & bolts 131 v type cross arm for 11kv line, 100x50x6 mm, gi 132 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 133 gi guarding angle iron 75x75x6 mm 3010 mm long 134 stone pad ( 300x300x75mm ) 135 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 136 11 kv polymer disc insulator b&s type 70 kn 137 disc fitting b&s type 70 kn 138 11 kv composite polymer pin insulator with nut and washers 139 11kv smc danger board with clamp, bolts & nuts 140 11kv smc number plate for clamp with n&b 141 11 kv stay set ( 16 x 1800 mm ) 142 11 kv stay clamp with nut and bolt 143 stay wire 7 / 10 swg 144 11 kv stay insulator 145 acsr dog conductor 146 p.g. clamp for acsr dog / raccoon 147 armour rod with ferrule for acsr dog / panther / raccoon helical performed 148 pcc pole, 8.5 mtr. long 149 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 150 aluminium binding wire 6 swg 151 aluminium jointing sleeves 152 g.i. barbed wire 153 gi wire 6 swg 154 gi wire 8 swg 155 gi wire 16 swg 156 eye bolt 157 turn buckle 158 11kv e bracket with n&b 159 11kv `f bracket with n&b 160 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 161 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 162 cross arm holding clamp with nuts & bolts 163 v type cross arm for 11kv line, 100x50x6 mm, gi 164 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 165 gi guarding angle iron 75x75x6 mm 3010 mm long 166 stone pad ( 300x300x75mm ) 167 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 168 11 kv railway crossing 169 11kv 3x185 mm2xlpe cable 170 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 171 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 172 cable route marker 173 g.i. pipe 6 dia . 174 11 mtr. stp 175 stone pad ( 300x300x75mm ) 176 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 177 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 178 11 kv polymer disc insulator b&s type 70 kn 179 disc fitting b&s type 70 kn 180 p.g. clamp for acsr dog / raccoon 181 11kv smc number plate for clamp with n&b 182 11kv smc danger board with clamp, bolts & nuts 183 g.i. barbed wire 184 aluminium binding wire 6 swg 185 aluminium paint 186 red oxide paint 187 11 kvstay set ( 16 x 1800 mm ) 188 11 kv stay clamp with nut and bolt 189 stay wire 7 / 10 swg 190 11 kv stay insulator 191 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 192 gi wire 6 swg 193 nhai / state highway crossing 194 11kv 3x185 mm2xlpe cable 195 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 196 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 197 cable route marker 198 g.i. pipe 6 dia . 199 11 mtr. stp 200 stone pad ( 300x300x75mm ) 201 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 202 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 203 11 kv polymer disc insulator b&s type 70 kn 204 disc fitting b&s type 70 kn 205 p.g. clamp for acsr dog / raccoon 206 11kv smc number plate for clamp with n&b 207 11kv smc danger board with clamp, bolts & nuts 208 g.i. barbed wire 209 aluminium binding wire 6 swg 210 aluminium paint 211 red oxide paint 212 11 kv stay set ( 16 x 1800 mm ) 213 11 kv stay clamp with nut and bolt 214 stay wire 7 / 10 swg 215 11 kv stay insulator 216 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 217 gi wire 6 swg 218 augumentation / reconductoring of 33 kv overhead line with dog conductor 219 acsr dog conductor 220 pcc pole, 9.0 mtr. long 221 11 mtr. stp 222 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 223 gi wire 6 swg 224 33 kv composite polymer pin insulator with nut and washers 225 aluminium paint 226 red oxide paint 227 33kv smc danger board with clamp and n&b 228 33kv smc number plate with clampand n&b 229 stone pad ( 300x300x75mm ) 230 g.i. barbed wire 231 33kv e bracket with n&b 232 33kv f bracket with n&b 233 v type cross arm for 33kv line 100x50x6 mm, gi 234 cross arm holding clamp with nuts & bolts 235 33 kv polymer disc insulator b&s type 70 kn 236 disc fitting b&s type 70 kn 237 33 kv stay set 238 33 kv stay clamp with nut and bolt 239 stay wire 7 / 8 swg 240 33 kv stay insulator 241 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 242 acsr dog conductor 243 11 kv polymer disc insulator b&s type 70 kn 244 disc fitting b&s type 70 kn 245 11 kv composite polymer pin insulator with nut and washers 246 11kv smc danger board with clamp, bolts & nuts 247 11kv smc number plate for clamp with n&b 248 11 kv stay set ( 16 x 1800 mm ) 249 11 kv stay clamp with nut and bolt 250 stay wire 7 / 10 swg 251 11 kv stay insulator 252 p.g. clamp for acsr dog / raccoon 253 armour rod with ferrule for acsr dog / panther / raccoon helical performed 254 pcc pole, 8.5 mtr. long 255 11 mtr. stp 256 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 257 aluminium binding wire 6 swg 258 aluminium jointing sleeves 259 g.i. barbed wire 260 gi wire 6 swg 261 gi wire 8 swg 262 gi wire 16 swg 263 eye bolt 264 turn buckle 265 red oxide paint 266 aluminium paint 267 11kv `f bracket with n&b 268 cross arm holding clamp with nuts & bolts 269 v type cross arm for 11kv line, 100x50x6 mm, gi 270 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 271 stone pad ( 300x300x75mm ) 272 11 kv agriculture feeder segregation & feeder splitting due to overloading 273 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 274 acsr rabbit conductor 275 11kv polymer disc insulator t&c type 45 kn 276 disc fittings t&c type 45 kn 277 11 kv composite polymer pin insulator with nut and washers 278 11kv smc danger board with clamp, bolts & nuts 279 11kv smc number plate for clamp with n&b 280 11 kv stay set ( 16 x 1800 mm ) 281 11 kv stay clamp with nut and bolt 282 stay wire 7 / 10 swg 283 11 kv stay insulator 284 pg clamps 285 armour rod with ferrule for acsr dog / panther / raccoon helical performed 286 pcc pole, 8.5 mtr. long 287 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 288 aluminium binding wire 6 swg 289 aluminium jointing sleeves 290 g.i. barbed wire 291 gi wire 6 swg 292 gi wire 8 swg 293 gi wire 16 swg 294 eye bolt 295 turn buckle 296 11kv e bracket with n&b 297 11kv `f bracket with n&b 298 gi top channel 100x50x2240 mm. 299 clamp with nuts & bolts for 1300 mm long gi channel 300 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 301 gi top channel 100x50x6, 1525 mm long 302 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 303 cross arm holding clamp with nuts & bolts 304 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 305 v type cross arm for 11kv line, 65x65x6 mm, gi angle 306 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 307 stone pad ( 300x300x75mm ) 308 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 309 pcc pole, 8.5 mtr. long 310 stone pad ( 300x300x75mm ) 311 lt clamp with nut and bolt for pcc pole 312 lt shakle insulator 100x115 mm 313 bolts and nuts for shackle insulators 314 acsr rabbit conductor 315 aluminium jointing sleeves 316 aluminium binding wire 6 swg 317 earth wire clamp 318 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 319 gi wire 6 swg 320 lt stay set ( 16 x 1800 mm ) 321 lt stay clamp with nut and bolt 322 stay wire 7 / 10 swg 323 lt stay insulator 324 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 325 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 326 pcc pole, 8.5 mtr. long 327 stone pad ( 300x300x75mm ) 328 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 329 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 330 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 331 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 332 gi channel 125x65x6, 1300mm ( tee off ) 333 clamp with nuts & bolts for 1300 mm long gi channel 334 11kv polymer disc insulator t&c type 45 kn 335 disc fittings t&c type 45 kn 336 11 kv composite polymer pin insulator with nut and washers 337 11kv tpmo complete set 338 11kv do fuse set ( 3 phase ) 339 11kv lightening arrestor 340 g.i. barbed wire 341 11kv smc danger board with clamp, bolts & nuts 342 deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 343 lt stay set ( 16 x 1800 mm ) 344 lt stay clamp with nut and bolt 345 stay wire 7 / 10 swg 346 lt stay insulator 347 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 348 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 349 lt pvc cable3.5x150 / 70sq.mm. 350 acsr weasel conductor 351 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 352 gi wire 6 swg 353 gi strip 25x3 mm 354 gi angle 100x50x2028mm ( fordistribution box ) ) 355 al. crimping lugs 150 sq.mm. 356 al. crimping lugs 70 sq.mm. 357 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 358 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 359 11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 360 pcc pole, 8.5 mtr. long 361 stone pad ( 300x300x75mm ) 362 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 363 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 364 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 365 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 366 gi channel 125x65x6, 1300mm ( tee off ) 367 clamp with nuts & bolts for 1300 mm long gi channel 368 11kv polymer disc insulator t&c type 45 kn 369 disc fittings t&c type 45 kn 370 11 kv composite polymer pin insulator with nut and washers 371 11kv tpmo complete set 372 11kv do fuse set ( 3 phase ) 373 11kv lightening arrestor 374 g.i. barbed wire 375 11kv smc danger board with clamp, bolts & nuts 376 deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 377 lt stay set ( 16 x 1800 mm ) 378 lt stay clamp with nut and bolt 379 stay wire 7 / 10 swg 380 lt stay insulator 381 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 382 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 383 lt pvc cable3.5x70 / 35sq.mm. 384 acsr weasel conductor 385 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 386 gi wire 6 swg 387 gi strip 25x3 mm 388 gi angle 100x50x2028mm ( fordistribution box ) ) 389 al. crimping lugs 70 sq.mm. 390 al. crimping lugs 35 sq.mm. 391 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 392 construction of new 25 kva, 11 / 0.433kv distribution transformer s / s 393 11 / 0.44 kv 25 kva transformer ( four star rating, level ii ) 394 pcc pole, 8.5 mtr. long 395 stone pad ( 300x300x75mm ) 396 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 397 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 398 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 399 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 400 gi channel 125x65x6, 1300mm ( tee off ) 401 clamp with nuts & bolts for 1300 mm long gi channel 402 11kv polymer disc insulator t&c type 45 kn 403 disc fittings t&c type 45 kn 404 11 kv composite polymer pin insulator with nut and washers 405 11kv tpmo complete set 406 11kv do fuse set ( 3 phase ) 407 11kv lightening arrestor 408 g.i. barbed wire 409 11kv smc danger board with clamp, bolts & nuts 410 deep drawn distribution boxas per technical specifications for 3 ph 25 kva dtr 411 lt stay set ( 16 x 1800 mm ) 412 lt stay clamp with nut and bolt 413 stay wire 7 / 10 swg 414 lt stay insulator 415 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 416 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 417 lt xlpe insulated unarmoured 4x25 sq. mm.cable 418 acsr weasel conductor 419 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 420 gi wire 6 swg 421 gi strip 25x3 mm 422 gi angle 100x50x2028mm ( fordistribution box ) ) 423 al. crimping lugs 25 sq.mm. 424 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 425 installation of 11 kv outgoing vcb for feeder segreration 426 11kv outgoing ctr 400 / 200 / 5a 350 mva 427 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 428 11kv 3x185 mm2xlpe cable 429 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 430 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 431 11 mtr. stp 432 gi top channel 100x50x2240 mm. 433 stone pad ( 300x300x75mm ) 434 11 kv polymer disc insulator b&s type 70 kn 435 disc fitting b&s type 70 kn 436 11 kv composite polymer pin insulator with nut and washers 437 p.g. clamp for acsr dog / raccoon 438 11kv e bracket with n&b 439 11kv smc number plate for clamp with n&b 440 11kv smc danger board with clamp, bolts & nuts 441 gi channel 125x65x2028 mm long ( dropper for fuse set ) 442 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 443 11kv tpmo complete set 444 11kv do fuse set ( 3 phase ) 445 11kv lightening arrestor 446 g.i. barbed wire 447 aluminium binding wire 6 swg 448 aluminium paint 449 red oxide paint 450 11 kv stay set ( 16 x 1800 mm ) 451 11 kv stay clamp with nut and bolt 452 stay wire 7 / 10 swg 453 11 kv stay insulator 454 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 455 gi strip 50x6 mm 456 gi wire 6 swg 457 g.i. pipe 6 dia . 458 11 kv railway crossing 459 11kv 3x185 mm2xlpe cable 460 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 461 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 462 cable route marker 463 g.i. pipe 6 dia . 464 11 mtr. stp 465 stone pad ( 300x300x75mm ) 466 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 467 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 468 11 kv polymer disc insulator b&s type 70 kn 469 disc fitting b&s type 70 kn 470 p.g. clamp for acsr dog / raccoon 471 11kv smc number plate for clamp with n&b 472 11kv smc danger board with clamp, bolts & nuts 473 g.i. barbed wire 474 aluminium binding wire 6 swg 475 aluminium paint 476 red oxide paint 477 11 kvstay set ( 16 x 1800 mm ) 478 11 kv stay clamp with nut and bolt 479 stay wire 7 / 10 swg 480 11 kv stay insulator 481 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 482 gi wire 6 swg 483 nhai / state highway crossing 484 11kv 3x185 mm2xlpe cable 485 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 486 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 487 cable route marker 488 g.i. pipe 6 dia . 489 11 mtr. stp 490 stone pad ( 300x300x75mm ) 491 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 492 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 493 11 kv polymer disc insulator b&s type 70 kn 494 disc fitting b&s type 70 kn 495 p.g. clamp for acsr dog / raccoon 496 11kv smc number plate for clamp with n&b 497 11kv smc danger board with clamp, bolts & nuts 498 g.i. barbed wire 499 aluminium binding wire 6 swg 500 aluminium paint 501 red oxide paint 502 11 kv stay set ( 16 x 1800 mm ) 503 11 kv stay clamp with nut and bolt 504 stay wire 7 / 10 swg 505 11 kv stay insulator 506 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 507 gi wire 6 swg 508 requirement of extra ab cable for new additional ckt at dts 509 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 510 pcc pole, 8.5 mtr. long 511 11 mtr. stp 512 stone pad ( 300x300x75mm ) 513 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 514 gi wire 6 swg 515 lt stay set ( 16 x 1800 mm ) 516 lt stay clamp with nut and bolt 517 stay wire 7 / 10 swg 518 lt stay insulator 519 dead end clamps with i hook ( insulated ) 520 suspension clamp with i hook 521 pole clamps with nut and bolt 522 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 523 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 524 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 525 lt abc of 3x50+1x35+1x16 sq. mm 526 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 527 end cap for lt ab cable 528 pg clamps 529 1x16 mm2 xlpe insulated al. cable for energising the street light 530 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 531 pcc pole, 8.5 mtr. long 532 11 mtr. stp 533 stone pad ( 300x300x75mm ) 534 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 535 gi wire 6 swg 536 lt stay set ( 16 x 1800 mm ) 537 lt stay clamp with nut and bolt 538 stay wire 7 / 10 swg 539 lt stay insulator 540 dead end clamps with i hook ( insulated ) 541 suspension clamp with i hook 542 pole clamps with nut and bolt 543 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 544 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 545 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 546 lt abc of 3x95+1x70+1x16 sq. mm 547 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 548 end cap for lt ab cable 549 pg clamps 550 1x16 mm2 xlpe insulated al. cable for energising the street light 551 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 552 pcc pole, 8.5 mtr. long 553 11 mtr. stp 554 stone pad ( 300x300x75mm ) 555 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 556 gi wire 6 swg 557 lt stay set ( 16 x 1800 mm ) 558 lt stay clamp with nut and bolt 559 stay wire 7 / 10 swg 560 lt stay insulator 561 dead end clamps with i hook ( insulated ) 562 suspension clamp with i hook 563 pole clamps with nut and bolt 564 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 565 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 566 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 567 lt abc of 3x120+1x95+1x16 sq. mm 568 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 569 end cap for lt ab cable 570 pg clamps 571 1x16 mm2 xlpe insulated al. cable for energising the street light 572 additional items that may be required for completion of work 573 3x120 sq. mm 11 kv ab cable 574 11kv polymer disc insulator with fitting for 11 kvabc 575 11kv polymer disc insulators with i hook 576 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 577 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 578 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 579 33kv 3x300 mm2xlpe cable 580 lt xlpe insulated unarmoured 1x50 sq. mm. cable 581 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 582 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 583 loop guard complete, 3 phase 584 spacers lt pvc 585 mid span jointing sleeves ( 95 sq. mm ) 586 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 587 supply of on / off switch for street light connections 588 height raising channel 100x50, 2240 mm long 589 back clamp for height raising channel holding clamps with bolts & nuts 590 cable jointing kit straight through ( 3x185 sqmm ) 591 cable jointing kit straight through ( 3x300sqmm ) 592 extra prefabricated gi items like clamp, channel, angle with nut & bolt 593 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 594 erection of pcc pole, 8.5 mtr. long 595 fixing of bolts and nuts for shackle insulators 596 fixing of lt shakle insulator 100x115 mm 597 fixing of d straps 598 stringing of lt xlpe armoured 3.5x50 sq. mm. cable 599 fixing of mid span jointing sleeves ( 120 sq. mm ) 600 fixing of insulating piercing connector ( 50 150 sq.mm ) 601 fixing of insulation mastic tape ( 2inc x 10 feet ) . 602 fixing of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 603 fixing of single phase deep drawn distribution box with clamps and suitable lock and key arrangment 604 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 605 1x16 mm2 xlpe insulated al. cable for energising the street light 606 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 607 gi wire 6 swg 608 erection of lt stay set ( 16 x 1800 mm ) 609 fixing of lt stay clamp with nut and bolt 610 erection of stay wire 7 / 10 swg 611 fixing of lt stay insulator 612 concreting of stay set ( 16x 1800 mm ) 613 stone pad ( 300x300x75mm ) 614 fixing of lt clamp with nut and bolt for pcc pole 615 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 616 concreting of pole / support ( 0.268 cu.m. ) 617 fixing of angle for vertical arm l50x50x6 ( type a ) 618 fixing of angle for vertical arm l50x50x6 ( type b ) 619 fixing of top clamp for vertical arm ( type a ) 620 fixing of top clamp for vertical arm ( type b ) 621 fixing of bottom clamp for vertical arm ( type a ) 622 fixing of bottom clamp for vertical arm ( type b ) 623 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 624 stringing of pvc 2c x 6 sq.mm. armoured cable for service connection 625 dismanting of old line service cable and connection of new armoured cable 626 fixing of polycarbonated box for single phase consumer 627 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 628 stringing of pvc 4c x 16 sq.mm. armoured cable for service connection 629 dismanting of old line service cable and connection of new armoured cable 630 fixing of polycarbonated box for three phase consumer 631 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 632 erection of pcc pole, 8.5 mtr. long 633 stone pad ( 300x300x75mm ) 634 concreting of pole / support ( 0.268 cu.m. ) 635 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 636 gi wire 6 swg 637 erection of lt stay set ( 16 x 1800 mm ) 638 fixing of lt stay clamp with nut and bolt 639 erection of stay wire 7 / 10 swg 640 fixing of lt stay insulator 641 concreting of stay set ( 16x 1800 mm ) 642 fixing of dead end clamps with i hook ( insulated ) 643 fixing of suspension clamp with i hook 644 fixing of pole clamps with nut and bolt 645 fixing of holding clamp for round pole with nut and bolt 646 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 647 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 648 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 649 stringing of lt abc of 3x50+1x35+1x16 sq. mm 650 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 651 1x16 mm2 xlpe insulated al. cable for energising the street light 652 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 653 fixing of end cap for lt ab cable 654 fixing of pg clamps 655 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 656 erection of pcc pole, 8.5 mtr. long 657 stone pad ( 300x300x75mm ) 658 concreting of pole / support ( 0.268 cu.m. ) 659 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 660 gi wire 6 swg 661 erection of lt stay set ( 16 x 1800 mm ) 662 fixing of lt stay clamp with nut and bolt 663 erection of stay wire 7 / 10 swg 664 fixing of lt stay insulator 665 concreting of stay set ( 16x 1800 mm ) 666 dead end clamps with i hook ( insulated ) 667 fixing of suspension clamp with i hook 668 fixing of pole clamps with nut and bolt 669 holding clamp for round pole with nut and bolt 670 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 671 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 672 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 673 stringing of lt abc of 3x95+1x70+1x16 sq. mm 674 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 675 1x16 mm2 xlpe insulated al. cable for energising the street light 676 end cap for lt ab cable 677 fixing of pg clamps 678 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 679 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 680 erection of pcc pole, 8.5 mtr. long 681 stone pad ( 300x300x75mm ) 682 concreting of pole / support ( 0.268 cu.m. ) 683 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 684 gi wire 6 swg 685 erection of lt stay set ( 16 x 1800 mm ) 686 fixing of lt stay clamp with nut and bolt 687 erection of stay wire 7 / 10 swg 688 fixing of lt stay insulator 689 concreting of stay set ( 16x 1800 mm ) 690 dead end clamps with i hook ( insulated ) 691 fixing of suspension clamp with i hook 692 fixing of pole clamps with nut and bolt 693 holding clamp for round pole with nut and bolt 694 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 695 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 696 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 697 stringing of lt abc of 3x120+1x95+1x16 sq. mm 698 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 699 1x16 mm2 xlpe insulated al. cable for energising the street light 700 end cap for lt ab cable 701 fixing of pg clamps 702 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 703 feeder bifurcation ( 11 kv line ) 704 11kv new line on 11 mtr. st pole with acsr dog conductor 705 erection of 11 kv polymer disc insulator b&s type 70 kn 706 erection of disc fitting b&s type 70 kn 707 erection of 11 kv composite polymer pin insulator with nut and washers 708 fixing of 11kv smc danger board with clamp, bolts & nuts 709 fixing of 11kv smc number plate for clamp with n&b 710 erection of 11 kv stay set ( 16 x 1800 mm ) 711 fixing of 11 kv stay clamp with nut and bolt 712 erection of stay wire 7 / 10 swg 713 fixing of 11 kv stay insulator 714 concreting of stay set ( 16x 1800 mm ) 715 stringing of acsr dog conductor 716 fixing of p.g. clamp for acsr dog / raccoon 717 armour rod with ferrule for acsr dog / panther / raccoon helical performed 718 erection of 11 mtr. stp 719 erection of 13 mtr. stp 720 concreting of pole / support ( 0.44 cu.m. ) 721 concreting of pole ( 0.64 cu.m. ) 722 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 723 aluminium binding wire 6 swg 724 aluminium jointing sleeves 725 g.i. barbed wire 726 gi wire 6 swg 727 gi wire 8 swg 728 gi wire 16 swg 729 eye bolt 730 turn buckle 731 painting of st pole with red oxide paint 732 painting of st pole with aluminium paint 733 erection of 11kv e bracket with n&b 734 erection of 11kv `f bracket with n&b 735 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 736 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 737 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 738 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 739 cross arm holding clamp with nuts & bolts 740 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 741 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 742 gi guarding angle iron 75x75x6 mm 3010 mm long 743 tree cutting compensation 744 stone pad ( 300x300x75mm ) 745 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 746 erection of 11 kv polymer disc insulator b&s type 70 kn 747 erection of disc fitting b&s type 70 kn 748 erection of 11 kv composite polymer pin insulator with nut and washers 749 fixing of 11kv smc danger board with clamp, bolts & nuts 750 fixing of 11kv smc number plate for clamp with n&b 751 erection of 11 kv stay set ( 16 x 1800 mm ) 752 fixing of 11 kv stay clamp with nut and bolt 753 erection of stay wire 7 / 10 swg 754 fixing of 11 kv stay insulator 755 concreting of stay set ( 16x 1800 mm ) 756 stringing of acsr dog conductor 757 fixing of p.g. clamp for acsr dog / raccoon 758 armour rod with ferrule for acsr dog / panther / raccoon helical performed 759 erection of pcc pole, 8.5 mtr. long 760 concreting of pole / support ( 0.268 cu.m. ) 761 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 762 aluminium binding wire 6 swg 763 aluminium jointing sleeves 764 g.i. barbed wire 765 gi wire 6 swg 766 gi wire 8 swg 767 gi wire 16 swg 768 eye bolt 769 turn buckle 770 erection of 11kv e bracket with n&b 771 erection of 11kv `f bracket with n&b 772 gi top channel 125x65mm, 3200 mm with clamp, bolts, nuts and washers 773 gi angle 65x65x6mm, 4300 mm long bracing with 4 clamps, bolts, nuts and washers 774 cross arm holding clamp with nuts & bolts 775 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 776 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 777 gi guarding angle iron 75x75x6 mm 3010 mm long 778 tree cutting compensation 779 stone pad ( 300x300x75mm ) 780 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 781 11 kv railway crossing 782 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 783 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 784 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 785 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 786 cable route marker 787 g.i. pipe 6 dia . 788 erection of 11 mtr. stp 789 stone pad ( 300x300x75mm ) 790 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 791 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 792 erection of 11 kv polymer disc insulator b&s type 70 kn 793 erection of disc fitting b&s type 70 kn 794 fixing of p.g. clamp for acsr dog / raccoon 795 fixing of 11kv smc number plate for clamp with n&b 796 fixing of 11kv smc danger board with clamp, bolts & nuts 797 g.i. barbed wire 798 aluminium binding wire 6 swg 799 painting of st pole with aluminium paint 800 painting of st pole with red oxide paint 801 erection of 11 kvstay set ( 16 x 1800 mm ) 802 fixing of 11 kv stay clamp with nut and bolt 803 erection of stay wire 7 / 10 swg 804 fixing of 11 kv stay insulator 805 concreting of stay set ( 16x 1800 mm ) 806 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 807 gi wire 6 swg 808 concreting of pole / support ( 0.44 cu.m. ) 809 railway crossing documentation, land and approval fee etc. 810 nhai / state highway crossing 811 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 812 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 813 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 814 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 815 cable route marker 816 g.i. pipe 6 dia . 817 erection of 11 mtr. stp 818 stone pad ( 300x300x75mm ) 819 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 820 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 821 erection of 11 kv polymer disc insulator b&s type 70 kn 822 disc fitting b&s type 70 kn 823 fixing of p.g. clamp for acsr dog / raccoon 824 fixing of 11kv smc number plate for clamp with n&b 825 fixing of 11kv smc danger board with clamp, bolts & nuts 826 g.i. barbed wire 827 aluminium binding wire 6 swg 828 painting of st pole with aluminium paint 829 painting of st pole with red oxide paint 830 erection of 11 kv stay set ( 16 x 1800 mm ) 831 fixing of 11 kv stay clamp with nut and bolt 832 erection of stay wire 7 / 10 swg 833 fixing of 11 kv stay insulator 834 concreting of stay set ( 16x 1800 mm ) 835 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 836 gi wire 6 swg 837 concreting of pole / support ( 0.44 cu.m. ) 838 nhai / state highway crossing documentation, land charges and approval fee etc. 839 road restoration charges 840 augumentation / reconductoring of 33 kv overhead line with dog conductor 841 stringing of acsr dog conductor 842 erection of pcc pole, 9.0 mtr. long 843 erection of 11 mtr. stp 844 concreting of pole / support ( 0.286 cu.m. ) 845 concreting of pole / support ( 0.44 cu.m. ) 846 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 847 gi wire 6 swg 848 erection of 33 kv composite polymer pin insulator with nut and washers 849 painting of st pole with aluminium paint 850 painting of st pole with red oxide paint 851 fixing of 33kv smc danger board with clamp and n&b 852 fixing of 33kv smc number plate with clampand n&b 853 stone pad ( 300x300x75mm ) 854 g.i. barbed wire 855 erection of 33kv e bracket with n&b 856 erection of 33kv f bracket with n&b 857 erection of v type cross arm for 33kv line 100x50x6 mm, gi 858 cross arm holding clamp with nuts & bolts 859 erection of 33 kv polymer disc insulator b&s type 70 kn 860 disc fitting b&s type 70 kn 861 erection of 33 kv stay set 862 fixing of 33 kv stay clamp with nut and bolt 863 erection of stay wire 7 / 8 swg 864 fixing of 33 kv stay insulator 865 concreting of 33 kv stay set 866 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 867 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 868 stringing of acsr dog conductor 869 erection of 11 kv polymer disc insulator b&s type 70 kn 870 disc fitting b&s type 70 kn 871 erection of 11 kv composite polymer pin insulator with nut and washers 872 fixing of 11kv smc danger board with clamp, bolts & nuts 873 fixing of 11kv smc number plate for clamp with n&b 874 erection of 11 kv stay set ( 16 x 1800 mm ) 875 fixing of 11 kv stay clamp with nut and bolt 876 erection of stay wire 7 / 10 swg 877 fixing of 11 kv stay insulator 878 concreting of stay set ( 16x 1800 mm ) 879 fixing of p.g. clamp for acsr dog / raccoon 880 armour rod with ferrule for acsr dog / panther / raccoon helical performed 881 erection of pcc pole, 8.5 mtr. long 882 erection of 11 mtr. stp 883 concreting of pole / support ( 0.268 cu.m. ) 884 concreting of pole / support ( 0.44 cu.m. ) 885 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 886 aluminium binding wire 6 swg 887 aluminium jointing sleeves 888 g.i. barbed wire 889 gi wire 6 swg 890 gi wire 8 swg 891 gi wire 16 swg 892 eye bolt 893 turn buckle 894 painting of st pole with red oxide paint 895 painting of st pole with aluminium paint 896 erection of 11kv `f bracket with n&b 897 cross arm holding clamp with nuts & bolts 898 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 899 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 900 stone pad ( 300x300x75mm ) 901 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 902 11 kv agriculture feeder segregation & feeder splitting due to overloading 903 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 904 stringing of acsr rabbit conductor 905 erection of 11kv polymer disc insulator t&c type 45 kn 906 disc fittings t&c type 45 kn 907 erection of 11 kv composite polymer pin insulator with nut and washers 908 fixing of 11kv smc danger board with clamp, bolts & nuts 909 fixing of 11kv smc number plate for clamp with n&b 910 erection of 11 kv stay set ( 16 x 1800 mm ) 911 fixing of 11 kv stay clamp with nut and bolt 912 erection of stay wire 7 / 10 swg 913 fixing of 11 kv stay insulator 914 concreting of stay set ( 16x 1800 mm ) 915 fixing of pg clamps 916 armour rod with ferrule for acsr dog / panther / raccoon helical performed 917 erection of pcc pole, 8.5 mtr. long 918 concreting of pole / support ( 0.268 cu.m. ) 919 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 920 aluminium binding wire 6 swg 921 aluminium jointing sleeves 922 g.i. barbed wire 923 gi wire 6 swg 924 gi wire 8 swg 925 gi wire 16 swg 926 eye bolt 927 turn buckle 928 erection of 11kv e bracket with n&b 929 erection of 11kv `f bracket with n&b 930 gi top channel 100x50x2240 mm. 931 clamp with nuts & bolts for 1300 mm long gi channel 932 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 933 gi top channel 100x50x6, 1525 mm long 934 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 935 cross arm holding clamp with nuts & bolts 936 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 937 erection of v type cross arm for 11kv line, 65x65x6 mm, gi angle 938 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 939 tree cutting compensation 940 stone pad ( 300x300x75mm ) 941 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 942 erection of pcc pole, 8.5 mtr. long 943 stone pad ( 300x300x75mm ) 944 lt clamp with nut and bolt for pcc pole 945 lt shakle insulator 100x115 mm 946 bolts and nuts for shackle insulators 947 concreting of pole / support ( 0.268 cu.m. ) 948 stringing of acsr rabbit conductor 949 aluminium jointing sleeves 950 aluminium binding wire 6 swg 951 earth wire clamp 952 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 953 gi wire 6 swg 954 erection of lt stay set ( 16 x 1800 mm ) 955 fixing of lt stay clamp with nut and bolt 956 erection of stay wire 7 / 10 swg 957 fixing of lt stay insulator 958 concreting of stay set ( 16x 1800 mm ) 959 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 960 installation of 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 961 erection of pcc pole, 8.5 mtr. long 962 stone pad ( 300x300x75mm ) 963 concreting of pole / support ( 0.268 cu.m. ) 964 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 965 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 966 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 967 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 968 gi channel 125x65x6, 1300mm ( tee off ) 969 clamp with nuts & bolts for 1300 mm long gi channel 970 erection of 11kv polymer disc insulator t&c type 45 kn 971 disc fittings t&c type 45 kn 972 erection of 11 kv composite polymer pin insulator with nut and washers 973 erection of 11kv tpmo complete set 974 erection of 11kv do fuse set ( 3 phase ) 975 erection of 11kv lightening arrestor 976 g.i. barbed wire 977 fixing of 11kv smc danger board with clamp, bolts & nuts 978 fixing of deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 979 erection of lt stay set ( 16 x 1800 mm ) 980 fixing of lt stay clamp with nut and bolt 981 erection of stay wire 7 / 10 swg 982 fixing of lt stay insulator 983 concreting of stay set ( 16x 1800 mm ) 984 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 985 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 986 lt pvc cable3.5x150 / 70sq.mm. 987 acsr weasel conductor 988 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 989 gi wire 6 swg 990 gi strip 25x3 mm 991 gi angle 100x50x2028mm ( fordistribution box ) ) 992 al. crimping lugs 150 sq.mm. 993 al. crimping lugs 70 sq.mm. 994 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 995 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 996 installation of11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 997 erection of pcc pole, 8.5 mtr. long 998 stone pad ( 300x300x75mm ) 999 concreting of pole / support ( 0.268 cu.m. ) 1000 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1001 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 1002 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1003 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 1004 gi channel 125x65x6, 1300mm ( tee off ) 1005 clamp with nuts & bolts for 1300 mm long gi channel 1006 erection of 11kv polymer disc insulator t&c type 45 kn 1007 disc fittings t&c type 45 kn 1008 erection of 11 kv composite polymer pin insulator with nut and washers 1009 erection of 11kv tpmo complete set 1010 erection of 11kv do fuse set ( 3 phase ) 1011 erection of 11kv lightening arrestor 1012 g.i. barbed wire 1013 fixing of 11kv smc danger board with clamp, bolts & nuts 1014 fixing of deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 1015 erection of lt stay set ( 16 x 1800 mm ) 1016 fixing of lt stay clamp with nut and bolt 1017 erection of stay wire 7 / 10 swg 1018 fixing of lt stay insulator 1019 concreting of stay set ( 16x 1800 mm ) 1020 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 1021 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 1022 lt pvc cable3.5x70 / 35sq.mm. 1023 acsr weasel conductor 1024 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1025 gi wire 6 swg 1026 gi strip 25x3 mm 1027 gi angle 100x50x2028mm ( fordistribution box ) ) 1028 al. crimping lugs 70 sq.mm. 1029 al. crimping lugs 35 sq.mm. 1030 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 1031 construction of new 25 kva, 11 / 0.433kv distribution transformer s / s 1032 installation of11 / 0.44 kv 25 kva transformer ( four star rating, level ii ) 1033 erection of pcc pole, 8.5 mtr. long 1034 stone pad ( 300x300x75mm ) 1035 concreting of pole / support ( 0.268 cu.m. ) 1036 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1037 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 1038 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1039 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 1040 gi channel 125x65x6, 1300mm ( tee off ) 1041 clamp with nuts & bolts for 1300 mm long gi channel 1042 erection of 11kv polymer disc insulator t&c type 45 kn 1043 disc fittings t&c type 45 kn 1044 erection of 11 kv composite polymer pin insulator with nut and washers 1045 erection of 11kv tpmo complete set 1046 erection of 11kv do fuse set ( 3 phase ) 1047 erection of 11kv lightening arrestor 1048 g.i. barbed wire 1049 fixing of 11kv smc danger board with clamp, bolts & nuts 1050 fixing of deep drawn distribution boxas per technical specifications for 3 ph 25 kva dtr 1051 erection of lt stay set ( 16 x 1800 mm ) 1052 fixing of lt stay clamp with nut and bolt 1053 erection of stay wire 7 / 10 swg 1054 fixing of lt stay insulator 1055 concreting of stay set ( 16x 1800 mm ) 1056 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 1057 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 1058 lt xlpe insulated unarmoured 4x25 sq. mm.cable 1059 acsr weasel conductor 1060 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1061 gi wire 6 swg 1062 gi strip 25x3 mm 1063 gi angle 100x50x2028mm ( fordistribution box ) ) 1064 al. crimping lugs 25 sq.mm. 1065 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 1066 installation of 11 kv outgoing vcb for feeder segreration 1067 installation of 11kv outgoing ctr 400 / 200 / 5a 350 mva 1068 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 1069 11kv 3x185 mm2xlpe cable 1070 laying of 11 kv cable including cost of sand & bricks 1071 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1072 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1073 erection of 11 mtr. stp 1074 gi top channel 100x50x2240 mm. 1075 stone pad ( 300x300x75mm ) 1076 erection of 11 kv polymer disc insulator b&s type 70 kn 1077 disc fitting b&s type 70 kn 1078 erection of 11 kv composite polymer pin insulator with nut and washers 1079 fixing of p.g. clamp for acsr dog / raccoon 1080 erection of 11kv e bracket with n&b 1081 fixing of 11kv smc number plate for clamp with n&b 1082 fixing of 11kv smc danger board with clamp, bolts & nuts 1083 gi channel 125x65x2028 mm long ( dropper for fuse set ) 1084 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1085 erection of 11kv tpmo complete set 1086 erection of 11kv do fuse set ( 3 phase ) 1087 erection of 11kv lightening arrestor 1088 g.i. barbed wire 1089 aluminium binding wire 6 swg 1090 painting of st pole with aluminium paint 1091 painting of st pole with red oxide paint 1092 erection of 11 kv stay set ( 16 x 1800 mm ) 1093 fixing of 11 kv stay clamp with nut and bolt 1094 erection of stay wire 7 / 10 swg 1095 fixing of 11 kv stay insulator 1096 concreting of stay set ( 16x 1800 mm ) 1097 concreting of pole / support ( 0.44 cu.m. ) 1098 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1099 gi strip 50x6 mm 1100 gi wire 6 swg 1101 g.i. pipe 6 dia . 1102 control room extension 1103 extension of existing substationcontrol room building. ( as per annexure attached in tender documents. ) 1104 11 kv railway crossing 1105 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1106 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1107 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1108 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1109 cable route marker 1110 g.i. pipe 6 dia . 1111 erection of 11 mtr. stp 1112 stone pad ( 300x300x75mm ) 1113 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1114 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1115 erection of 11 kv polymer disc insulator b&s type 70 kn 1116 disc fitting b&s type 70 kn 1117 fixing of p.g. clamp for acsr dog / raccoon 1118 fixing of 11kv smc number plate for clamp with n&b 1119 fixing of 11kv smc danger board with clamp, bolts & nuts 1120 g.i. barbed wire 1121 aluminium binding wire 6 swg 1122 painting of st pole with aluminium paint 1123 painting of st pole with red oxide paint 1124 erection of 11 kvstay set ( 16 x 1800 mm ) 1125 fixing of 11 kv stay clamp with nut and bolt 1126 erection of stay wire 7 / 10 swg 1127 fixing of 11 kv stay insulator 1128 concreting of stay set ( 16x 1800 mm ) 1129 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1130 gi wire 6 swg 1131 concreting of pole / support ( 0.44 cu.m. ) 1132 railway crossing documentation, land and approval fee etc. 1133 nhai / state highway crossing 1134 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1135 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1136 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1137 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1138 cable route marker 1139 g.i. pipe 6 dia . 1140 erection of 11 mtr. stp 1141 stone pad ( 300x300x75mm ) 1142 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1143 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1144 erection of 11 kv polymer disc insulator b&s type 70 kn 1145 disc fitting b&s type 70 kn 1146 fixing of p.g. clamp for acsr dog / raccoon 1147 fixing of 11kv smc number plate for clamp with n&b 1148 fixing of 11kv smc danger board with clamp, bolts & nuts 1149 g.i. barbed wire 1150 aluminium binding wire 6 swg 1151 painting of st pole with aluminium paint 1152 painting of st pole with red oxide paint 1153 erection of 11 kv stay set ( 16 x 1800 mm ) 1154 fixing of 11 kv stay clamp with nut and bolt 1155 erection of stay wire 7 / 10 swg 1156 fixing of 11 kv stay insulator 1157 concreting of stay set ( 16x 1800 mm ) 1158 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1159 gi wire 6 swg 1160 concreting of pole / support ( 0.44 cu.m. ) 1161 nhai / state highway crossing documentation, land charges and approval fee etc. 1162 road restoration charges 1163 requirement of extra ab cable for new additional ckt at dts 1164 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 1165 erection of pcc pole, 8.5 mtr. long 1166 erection of 11 mtr. stp 1167 stone pad ( 300x300x75mm ) 1168 concreting of pole / support ( 0.268 cu.m. ) 1169 concreting of pole / support ( 0.44 cu.m. ) 1170 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1171 gi wire 6 swg 1172 erection of lt stay set ( 16 x 1800 mm ) 1173 fixing of lt stay clamp with nut and bolt 1174 erection of stay wire 7 / 10 swg 1175 fixing of lt stay insulator 1176 concreting of stay set ( 16x 1800 mm ) 1177 dead end clamps with i hook ( insulated ) 1178 fixing of suspension clamp with i hook 1179 fixing of pole clamps with nut and bolt 1180 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1181 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1182 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1183 stringing of lt abc of 3x50+1x35+1x16 sq. mm 1184 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1185 end cap for lt ab cable 1186 fixing of pg clamps 1187 1x16 mm2 xlpe insulated al. cable for energising the street light 1188 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 1189 erection of pcc pole, 8.5 mtr. long 1190 erection of 11 mtr. stp 1191 stone pad ( 300x300x75mm ) 1192 concreting of pole / support ( 0.268 cu.m. ) 1193 concreting of pole / support ( 0.44 cu.m. ) 1194 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1195 gi wire 6 swg 1196 erection of lt stay set ( 16 x 1800 mm ) 1197 fixing of lt stay clamp with nut and bolt 1198 erection of stay wire 7 / 10 swg 1199 fixing of lt stay insulator 1200 concreting of stay set ( 16x 1800 mm ) 1201 dead end clamps with i hook ( insulated ) 1202 fixing of suspension clamp with i hook 1203 fixing of pole clamps with nut and bolt 1204 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1205 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1206 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1207 stringing of lt abc of 3x95+1x70+1x16 sq. mm 1208 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1209 end cap for lt ab cable 1210 fixing of pg clamps 1211 1x16 mm2 xlpe insulated al. cable for energising the street light 1212 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 1213 erection of pcc pole, 8.5 mtr. long 1214 erection of 11 mtr. stp 1215 stone pad ( 300x300x75mm ) 1216 concreting of pole / support ( 0.268 cu.m. ) 1217 concreting of pole / support ( 0.44 cu.m. ) 1218 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1219 gi wire 6 swg 1220 erection of lt stay set ( 16 x 1800 mm ) 1221 fixing of lt stay clamp with nut and bolt 1222 erection of stay wire 7 / 10 swg 1223 fixing of lt stay insulator 1224 concreting of stay set ( 16x 1800 mm ) 1225 dead end clamps with i hook ( insulated ) 1226 fixing of suspension clamp with i hook 1227 fixing of pole clamps with nut and bolt 1228 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1229 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1230 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1231 stringing of lt abc of 3x120+1x95+1x16 sq. mm 1232 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1233 end cap for lt ab cable 1234 fixing of pg clamps 1235 1x16 mm2 xlpe insulated al. cable for energising the street light 1236 additional items that may be required for completion of work 1237 3x120 sq. mm 11 kv ab cable 1238 11kv polymer disc insulator with fitting for 11 kvabc 1239 11kv polymer disc insulators with i hook 1240 erection & concreting of extra stud pole complete with clamps, 1241 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 1242 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 1243 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 1244 lt xlpe insulated unarmoured 1x50 sq. mm. cable 1245 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 1246 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 1247 laying of 3x300 sq. mm. 33 kv xlpe insulated cable underground in hdpe pipe or trenches ( for railway / road crossing ) 1248 drilling & laying of ht underground cable using hdd method without using hdpe pipe 1249 loop guard complete, 3 phase 1250 spacers lt pvc 1251 mid span jointing sleeves ( 95 sq. mm ) 1252 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 1253 fixing of on / off switch for street light connections 1254 mounting of cable on dp structure ( including loop and riser ) 1255 height raising channel 100x50, 2240 mm long 1256 back clamp for height raising channel holding clamps with bolts & nuts 1257 cable jointing kit straight through ( 3x185 sqmm ) 1258 cable jointing kit straight through ( 3x300sqmm ) 1259 extra prefabricated gi items like clamp, channel, angle with nut & bolt...

Paschimanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32106581 development of distribution infrastructure for loss reduction works atdistrict muzaffarnagar, shamli and saharanpur of uttar pradesh under revamped reforms based and results linked, distribution sector scheme 0 1 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 2 pcc pole, 8.5 mtr. long 3 bolts and nuts for shackle insulators 4 lt shakle insulator 100x115 mm 5 d straps 6 lt xlpe armoured 3.5x50 sq. mm. cable 7 mid span jointing sleeves ( 50 sq. mm ) 8 insulating piercing connector ( 50 150 sq.mm ) 9 insulation mastic tape ( 2inc x 10 feet ) . 10 supply of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 11 supply of single of phase deep drawn distribution box with clamps and suitable lock and key arrangment 12 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 13 1x16 mm2 xlpe insulated al. cable for energising the street light 14 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 15 gi wire 6 swg 16 lt stay set ( 16 x 1800 mm ) 17 lt stay clamp with nut and bolt 18 stay wire 7 / 10 swg 19 lt stay insulator 20 stone pad ( 300x300x75mm ) 21 lt clamp with nut and bolt for pcc pole 22 angle for vertical arm l50x50x6 ( type a ) 23 angle for vertical arm l50x50x6 ( type b ) 24 top clamp for vertical arm ( type a ) 25 top clamp for vertical arm ( type b ) 26 bottom clamp for vertical arm ( type a ) 27 bottom clamp for vertical arm ( type b ) 28 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 29 pvc 2c x 6 sq.mm. armoured cable for service connection 30 polycarbonated box for single phase consumer 31 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 32 pvc 4c x 16 sq.mm. armoured cable for service connection 33 polycarbonated box for three phase consumer 34 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 35 pcc pole, 8.5 mtr. long 36 stone pad ( 300x300x75mm ) 37 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 38 gi wire 6 swg 39 lt stay set ( 16 x 1800 mm ) 40 lt stay clamp with nut and bolt 41 stay wire 7 / 10 swg 42 lt stay insulator 43 dead end clamps with i hook ( insulated ) 44 suspension clamp with i hook 45 pole clamps with nut and bolt 46 holding clamp for round pole with nut and bolt 47 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 48 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 49 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 50 lt abc of 3x50+1x35+1x16 sq. mm 51 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 52 1x16 mm2 xlpe insulated al. cable for energising the street light 53 end cap for lt ab cable 54 pg clamps 55 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 56 pcc pole, 8.5 mtr. long 57 stone pad ( 300x300x75mm ) 58 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 59 gi wire 6 swg 60 lt stay set ( 16 x 1800 mm ) 61 lt stay clamp with nut and bolt 62 stay wire 7 / 10 swg 63 lt stay insulator 64 dead end clamps with i hook ( insulated ) 65 suspension clamp with i hook 66 pole clamps with nut and bolt 67 holding clamp for round pole with nut and bolt 68 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 69 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 70 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 71 lt abc of 3x95+1x70+1x16 sq. mm 72 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 73 1x16 mm2 xlpe insulated al. cable for energising the street light 74 end cap for lt ab cable 75 pg clamps 76 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 77 pcc pole, 8.5 mtr. long 78 stone pad ( 300x300x75mm ) 79 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 80 gi wire 6 swg 81 lt stay set ( 16 x 1800 mm ) 82 lt stay clamp with nut and bolt 83 stay wire 7 / 10 swg 84 lt stay insulator 85 dead end clamps with i hook ( insulated ) 86 suspension clamp with i hook 87 pole clamps with nut and bolt 88 holding clamp for round pole with nut and bolt 89 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 90 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 91 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 92 lt abc of 3x120+1x95+1x16 sq. mm 93 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 94 1x16 mm2 xlpe insulated al. cable for energising the street light 95 end cap for lt ab cable 96 pg clamps 97 feeder bifurcation ( 11 kv line ) 98 11kv new line on 11 mtr. st pole with acsr dog conductor ( feeder bifurcation 11 kv line ) 99 11 kv polymer disc insulator b&s type 70 kn 100 disc fitting b&s type 70 kn 101 11 kv composite polymer pin insulator with nut and washers 102 11kv smc danger board with clamp, bolts & nuts 103 11kv smc number plate for clamp with n&b 104 11 kv stay set ( 16 x 1800 mm ) 105 11 kv stay clamp with nut and bolt 106 stay wire 7 / 10 swg 107 11 kv stay insulator 108 acsr dog conductor 109 p.g. clamp for acsr dog / raccoon 110 armour rod with ferrule for acsr dog / panther / raccoon helical performed 111 11 mtr. stp 112 13 mtr. stp 113 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 114 aluminium binding wire 6 swg 115 aluminium jointing sleeves 116 g.i. barbed wire 117 gi wire 6 swg 118 gi wire 8 swg 119 gi wire 16 swg 120 eye bolt 121 turn buckle 122 red oxide paint 123 aluminium paint 124 11kv e bracket with n&b 125 11kv `f bracket with n&b 126 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 127 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 128 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 129 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 130 cross arm holding clamp with nuts & bolts 131 v type cross arm for 11kv line, 100x50x6 mm, gi 132 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 133 gi guarding angle iron 75x75x6 mm 3010 mm long 134 stone pad ( 300x300x75mm ) 135 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 136 11 kv polymer disc insulator b&s type 70 kn 137 disc fitting b&s type 70 kn 138 11 kv composite polymer pin insulator with nut and washers 139 11kv smc danger board with clamp, bolts & nuts 140 11kv smc number plate for clamp with n&b 141 11 kv stay set ( 16 x 1800 mm ) 142 11 kv stay clamp with nut and bolt 143 stay wire 7 / 10 swg 144 11 kv stay insulator 145 acsr dog conductor 146 p.g. clamp for acsr dog / raccoon 147 armour rod with ferrule for acsr dog / panther / raccoon helical performed 148 pcc pole, 8.5 mtr. long 149 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 150 aluminium binding wire 6 swg 151 aluminium jointing sleeves 152 g.i. barbed wire 153 gi wire 6 swg 154 gi wire 8 swg 155 gi wire 16 swg 156 eye bolt 157 turn buckle 158 11kv e bracket with n&b 159 11kv `f bracket with n&b 160 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 161 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 162 cross arm holding clamp with nuts & bolts 163 v type cross arm for 11kv line, 100x50x6 mm, gi 164 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 165 gi guarding angle iron 75x75x6 mm 3010 mm long 166 stone pad ( 300x300x75mm ) 167 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 168 11 kv railway crossing 169 11kv 3x185 mm2xlpe cable 170 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 171 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 172 cable route marker 173 g.i. pipe 6 dia . 174 11 mtr. stp 175 stone pad ( 300x300x75mm ) 176 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 177 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 178 11 kv polymer disc insulator b&s type 70 kn 179 disc fitting b&s type 70 kn 180 p.g. clamp for acsr dog / raccoon 181 11kv smc number plate for clamp with n&b 182 11kv smc danger board with clamp, bolts & nuts 183 g.i. barbed wire 184 aluminium binding wire 6 swg 185 aluminium paint 186 red oxide paint 187 11 kvstay set ( 16 x 1800 mm ) 188 11 kv stay clamp with nut and bolt 189 stay wire 7 / 10 swg 190 11 kv stay insulator 191 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 192 gi wire 6 swg 193 nhai / state highway crossing 194 11kv 3x185 mm2xlpe cable 195 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 196 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 197 cable route marker 198 g.i. pipe 6 dia . 199 11 mtr. stp 200 stone pad ( 300x300x75mm ) 201 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 202 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 203 11 kv polymer disc insulator b&s type 70 kn 204 disc fitting b&s type 70 kn 205 p.g. clamp for acsr dog / raccoon 206 11kv smc number plate for clamp with n&b 207 11kv smc danger board with clamp, bolts & nuts 208 g.i. barbed wire 209 aluminium binding wire 6 swg 210 aluminium paint 211 red oxide paint 212 11 kv stay set ( 16 x 1800 mm ) 213 11 kv stay clamp with nut and bolt 214 stay wire 7 / 10 swg 215 11 kv stay insulator 216 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 217 gi wire 6 swg 218 augumentation / reconductoring of 33 kv overhead line with dog conductor 219 acsr dog conductor 220 pcc pole, 9.0 mtr. long 221 11 mtr. stp 222 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 223 gi wire 6 swg 224 33 kv composite polymer pin insulator with nut and washers 225 aluminium paint 226 red oxide paint 227 33kv smc danger board with clamp and n&b 228 33kv smc number plate with clampand n&b 229 stone pad ( 300x300x75mm ) 230 g.i. barbed wire 231 33kv e bracket with n&b 232 33kv f bracket with n&b 233 v type cross arm for 33kv line 100x50x6 mm, gi 234 cross arm holding clamp with nuts & bolts 235 33 kv polymer disc insulator b&s type 70 kn 236 disc fitting b&s type 70 kn 237 33 kv stay set 238 33 kv stay clamp with nut and bolt 239 stay wire 7 / 8 swg 240 33 kv stay insulator 241 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 242 acsr dog conductor 243 11 kv polymer disc insulator b&s type 70 kn 244 disc fitting b&s type 70 kn 245 11 kv composite polymer pin insulator with nut and washers 246 11kv smc danger board with clamp, bolts & nuts 247 11kv smc number plate for clamp with n&b 248 11 kv stay set ( 16 x 1800 mm ) 249 11 kv stay clamp with nut and bolt 250 stay wire 7 / 10 swg 251 11 kv stay insulator 252 p.g. clamp for acsr dog / raccoon 253 armour rod with ferrule for acsr dog / panther / raccoon helical performed 254 pcc pole, 8.5 mtr. long 255 11 mtr. stp 256 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 257 aluminium binding wire 6 swg 258 aluminium jointing sleeves 259 g.i. barbed wire 260 gi wire 6 swg 261 gi wire 8 swg 262 gi wire 16 swg 263 eye bolt 264 turn buckle 265 red oxide paint 266 aluminium paint 267 11kv `f bracket with n&b 268 cross arm holding clamp with nuts & bolts 269 v type cross arm for 11kv line, 100x50x6 mm, gi 270 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 271 stone pad ( 300x300x75mm ) 272 11 kv agriculture feeder segregation & feeder splitting due to overloading 273 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 274 acsr rabbit conductor 275 11kv polymer disc insulator t&c type 45 kn 276 disc fittings t&c type 45 kn 277 11 kv composite polymer pin insulator with nut and washers 278 11kv smc danger board with clamp, bolts & nuts 279 11kv smc number plate for clamp with n&b 280 11 kv stay set ( 16 x 1800 mm ) 281 11 kv stay clamp with nut and bolt 282 stay wire 7 / 10 swg 283 11 kv stay insulator 284 pg clamps 285 armour rod with ferrule for acsr dog / panther / raccoon helical performed 286 pcc pole, 8.5 mtr. long 287 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 288 aluminium binding wire 6 swg 289 aluminium jointing sleeves 290 g.i. barbed wire 291 gi wire 6 swg 292 gi wire 8 swg 293 gi wire 16 swg 294 eye bolt 295 turn buckle 296 11kv e bracket with n&b 297 11kv `f bracket with n&b 298 gi top channel 100x50x2240 mm. 299 clamp with nuts & bolts for 1300 mm long gi channel 300 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 301 gi top channel 100x50x6, 1525 mm long 302 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 303 cross arm holding clamp with nuts & bolts 304 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 305 v type cross arm for 11kv line, 65x65x6 mm, gi angle 306 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 307 stone pad ( 300x300x75mm ) 308 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 309 pcc pole, 8.5 mtr. long 310 stone pad ( 300x300x75mm ) 311 lt clamp with nut and bolt for pcc pole 312 lt shakle insulator 100x115 mm 313 bolts and nuts for shackle insulators 314 acsr rabbit conductor 315 aluminium jointing sleeves 316 aluminium binding wire 6 swg 317 earth wire clamp 318 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 319 gi wire 6 swg 320 lt stay set ( 16 x 1800 mm ) 321 lt stay clamp with nut and bolt 322 stay wire 7 / 10 swg 323 lt stay insulator 324 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 325 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 326 pcc pole, 8.5 mtr. long 327 stone pad ( 300x300x75mm ) 328 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 329 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 330 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 331 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 332 gi channel 125x65x6, 1300mm ( tee off ) 333 clamp with nuts & bolts for 1300 mm long gi channel 334 11kv polymer disc insulator t&c type 45 kn 335 disc fittings t&c type 45 kn 336 11 kv composite polymer pin insulator with nut and washers 337 11kv tpmo complete set 338 11kv do fuse set ( 3 phase ) 339 11kv lightening arrestor 340 g.i. barbed wire 341 11kv smc danger board with clamp, bolts & nuts 342 deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 343 lt stay set ( 16 x 1800 mm ) 344 lt stay clamp with nut and bolt 345 stay wire 7 / 10 swg 346 lt stay insulator 347 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 348 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 349 lt pvc cable3.5x150 / 70sq.mm. 350 acsr weasel conductor 351 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 352 gi wire 6 swg 353 gi strip 25x3 mm 354 gi angle 100x50x2028mm ( fordistribution box ) ) 355 al. crimping lugs 150 sq.mm. 356 al. crimping lugs 70 sq.mm. 357 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 358 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 359 11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 360 pcc pole, 8.5 mtr. long 361 stone pad ( 300x300x75mm ) 362 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 363 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 364 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 365 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 366 gi channel 125x65x6, 1300mm ( tee off ) 367 clamp with nuts & bolts for 1300 mm long gi channel 368 11kv polymer disc insulator t&c type 45 kn 369 disc fittings t&c type 45 kn 370 11 kv composite polymer pin insulator with nut and washers 371 11kv tpmo complete set 372 11kv do fuse set ( 3 phase ) 373 11kv lightening arrestor 374 g.i. barbed wire 375 11kv smc danger board with clamp, bolts & nuts 376 deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 377 lt stay set ( 16 x 1800 mm ) 378 lt stay clamp with nut and bolt 379 stay wire 7 / 10 swg 380 lt stay insulator 381 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 382 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 383 lt pvc cable3.5x70 / 35sq.mm. 384 acsr weasel conductor 385 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 386 gi wire 6 swg 387 gi strip 25x3 mm 388 gi angle 100x50x2028mm ( fordistribution box ) ) 389 al. crimping lugs 70 sq.mm. 390 al. crimping lugs 35 sq.mm. 391 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 392 construction of new 25 kva, 11 / 0.433kv distribution transformer s / s 393 11 / 0.44 kv 25 kva transformer ( four star rating, level ii ) 394 pcc pole, 8.5 mtr. long 395 stone pad ( 300x300x75mm ) 396 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 397 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 398 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 399 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 400 gi channel 125x65x6, 1300mm ( tee off ) 401 clamp with nuts & bolts for 1300 mm long gi channel 402 11kv polymer disc insulator t&c type 45 kn 403 disc fittings t&c type 45 kn 404 11 kv composite polymer pin insulator with nut and washers 405 11kv tpmo complete set 406 11kv do fuse set ( 3 phase ) 407 11kv lightening arrestor 408 g.i. barbed wire 409 11kv smc danger board with clamp, bolts & nuts 410 deep drawn distribution boxas per technical specifications for 3 ph 25 kva dtr 411 lt stay set ( 16 x 1800 mm ) 412 lt stay clamp with nut and bolt 413 stay wire 7 / 10 swg 414 lt stay insulator 415 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 416 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 417 lt xlpe insulated unarmoured 4x25 sq. mm.cable 418 acsr weasel conductor 419 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 420 gi wire 6 swg 421 gi strip 25x3 mm 422 gi angle 100x50x2028mm ( fordistribution box ) ) 423 al. crimping lugs 25 sq.mm. 424 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 425 installation of 11 kv outgoing vcb for feeder segreration 426 11kv outgoing ctr 400 / 200 / 5a 350 mva 427 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 428 11kv 3x185 mm2xlpe cable 429 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 430 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 431 11 mtr. stp 432 gi top channel 100x50x2240 mm. 433 stone pad ( 300x300x75mm ) 434 11 kv polymer disc insulator b&s type 70 kn 435 disc fitting b&s type 70 kn 436 11 kv composite polymer pin insulator with nut and washers 437 p.g. clamp for acsr dog / raccoon 438 11kv e bracket with n&b 439 11kv smc number plate for clamp with n&b 440 11kv smc danger board with clamp, bolts & nuts 441 gi channel 125x65x2028 mm long ( dropper for fuse set ) 442 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 443 11kv tpmo complete set 444 11kv do fuse set ( 3 phase ) 445 11kv lightening arrestor 446 g.i. barbed wire 447 aluminium binding wire 6 swg 448 aluminium paint 449 red oxide paint 450 11 kv stay set ( 16 x 1800 mm ) 451 11 kv stay clamp with nut and bolt 452 stay wire 7 / 10 swg 453 11 kv stay insulator 454 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 455 gi strip 50x6 mm 456 gi wire 6 swg 457 g.i. pipe 6 dia . 458 11 kv railway crossing 459 11kv 3x185 mm2xlpe cable 460 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 461 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 462 cable route marker 463 g.i. pipe 6 dia . 464 11 mtr. stp 465 stone pad ( 300x300x75mm ) 466 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 467 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 468 11 kv polymer disc insulator b&s type 70 kn 469 disc fitting b&s type 70 kn 470 p.g. clamp for acsr dog / raccoon 471 11kv smc number plate for clamp with n&b 472 11kv smc danger board with clamp, bolts & nuts 473 g.i. barbed wire 474 aluminium binding wire 6 swg 475 aluminium paint 476 red oxide paint 477 11 kvstay set ( 16 x 1800 mm ) 478 11 kv stay clamp with nut and bolt 479 stay wire 7 / 10 swg 480 11 kv stay insulator 481 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 482 gi wire 6 swg 483 nhai / state highway crossing 484 11kv 3x185 mm2xlpe cable 485 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 486 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 487 cable route marker 488 g.i. pipe 6 dia . 489 11 mtr. stp 490 stone pad ( 300x300x75mm ) 491 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 492 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 493 11 kv polymer disc insulator b&s type 70 kn 494 disc fitting b&s type 70 kn 495 p.g. clamp for acsr dog / raccoon 496 11kv smc number plate for clamp with n&b 497 11kv smc danger board with clamp, bolts & nuts 498 g.i. barbed wire 499 aluminium binding wire 6 swg 500 aluminium paint 501 red oxide paint 502 11 kv stay set ( 16 x 1800 mm ) 503 11 kv stay clamp with nut and bolt 504 stay wire 7 / 10 swg 505 11 kv stay insulator 506 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 507 gi wire 6 swg 508 requirement of extra ab cable for new additional ckt at dts 509 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 510 pcc pole, 8.5 mtr. long 511 11 mtr. stp 512 stone pad ( 300x300x75mm ) 513 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 514 gi wire 6 swg 515 lt stay set ( 16 x 1800 mm ) 516 lt stay clamp with nut and bolt 517 stay wire 7 / 10 swg 518 lt stay insulator 519 dead end clamps with i hook ( insulated ) 520 suspension clamp with i hook 521 pole clamps with nut and bolt 522 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 523 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 524 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 525 lt abc of 3x50+1x35+1x16 sq. mm 526 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 527 end cap for lt ab cable 528 pg clamps 529 1x16 mm2 xlpe insulated al. cable for energising the street light 530 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 531 pcc pole, 8.5 mtr. long 532 11 mtr. stp 533 stone pad ( 300x300x75mm ) 534 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 535 gi wire 6 swg 536 lt stay set ( 16 x 1800 mm ) 537 lt stay clamp with nut and bolt 538 stay wire 7 / 10 swg 539 lt stay insulator 540 dead end clamps with i hook ( insulated ) 541 suspension clamp with i hook 542 pole clamps with nut and bolt 543 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 544 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 545 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 546 lt abc of 3x95+1x70+1x16 sq. mm 547 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 548 end cap for lt ab cable 549 pg clamps 550 1x16 mm2 xlpe insulated al. cable for energising the street light 551 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 552 pcc pole, 8.5 mtr. long 553 11 mtr. stp 554 stone pad ( 300x300x75mm ) 555 earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 556 gi wire 6 swg 557 lt stay set ( 16 x 1800 mm ) 558 lt stay clamp with nut and bolt 559 stay wire 7 / 10 swg 560 lt stay insulator 561 dead end clamps with i hook ( insulated ) 562 suspension clamp with i hook 563 pole clamps with nut and bolt 564 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 565 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 566 supply ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 567 lt abc of 3x120+1x95+1x16 sq. mm 568 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 569 end cap for lt ab cable 570 pg clamps 571 1x16 mm2 xlpe insulated al. cable for energising the street light 572 additional items that may be required for completion of work 573 3x120 sq. mm 11 kv ab cable 574 11kv polymer disc insulator with fitting for 11 kvabc 575 11kv polymer disc insulators with i hook 576 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 577 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 578 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 579 33kv 3x300 mm2xlpe cable 580 lt xlpe insulated unarmoured 1x50 sq. mm. cable 581 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 582 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 583 loop guard complete, 3 phase 584 spacers lt pvc 585 mid span jointing sleeves ( 95 sq. mm ) 586 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 587 supply of on / off switch for street light connections 588 height raising channel 100x50, 2240 mm long 589 back clamp for height raising channel holding clamps with bolts & nuts 590 cable jointing kit straight through ( 3x185 sqmm ) 591 cable jointing kit straight through ( 3x300sqmm ) 592 extra prefabricated gi items like clamp, channel, angle with nut & bolt 593 armouredlt cabling in high loss area ( lt line on 3.5cx 50 sq.mm armoured cable ) 594 erection of pcc pole, 8.5 mtr. long 595 fixing of bolts and nuts for shackle insulators 596 fixing of lt shakle insulator 100x115 mm 597 fixing of d straps 598 stringing of lt xlpe armoured 3.5x50 sq. mm. cable 599 fixing of mid span jointing sleeves ( 120 sq. mm ) 600 fixing of insulating piercing connector ( 50 150 sq.mm ) 601 fixing of insulation mastic tape ( 2inc x 10 feet ) . 602 fixing of three phase deep drawn distribution box with clamps and suitable lock and key arrangment 603 fixing of single phase deep drawn distribution box with clamps and suitable lock and key arrangment 604 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 605 1x16 mm2 xlpe insulated al. cable for energising the street light 606 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 607 gi wire 6 swg 608 erection of lt stay set ( 16 x 1800 mm ) 609 fixing of lt stay clamp with nut and bolt 610 erection of stay wire 7 / 10 swg 611 fixing of lt stay insulator 612 concreting of stay set ( 16x 1800 mm ) 613 stone pad ( 300x300x75mm ) 614 fixing of lt clamp with nut and bolt for pcc pole 615 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 616 concreting of pole / support ( 0.268 cu.m. ) 617 fixing of angle for vertical arm l50x50x6 ( type a ) 618 fixing of angle for vertical arm l50x50x6 ( type b ) 619 fixing of top clamp for vertical arm ( type a ) 620 fixing of top clamp for vertical arm ( type b ) 621 fixing of bottom clamp for vertical arm ( type a ) 622 fixing of bottom clamp for vertical arm ( type b ) 623 armouredconsumer cabling in high loss area ( service line on single phase 2cx 6 sq.mm ) 624 stringing of pvc 2c x 6 sq.mm. armoured cable for service connection 625 dismanting of old line service cable and connection of new armoured cable 626 fixing of polycarbonated box for single phase consumer 627 armouredcomsumer cabling in high loss area ( service line on three phase 4cx 16 sq.mm ) 628 stringing of pvc 4c x 16 sq.mm. armoured cable for service connection 629 dismanting of old line service cable and connection of new armoured cable 630 fixing of polycarbonated box for three phase consumer 631 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x50+1x35+1x16 ) sq.mm. 632 erection of pcc pole, 8.5 mtr. long 633 stone pad ( 300x300x75mm ) 634 concreting of pole / support ( 0.268 cu.m. ) 635 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 636 gi wire 6 swg 637 erection of lt stay set ( 16 x 1800 mm ) 638 fixing of lt stay clamp with nut and bolt 639 erection of stay wire 7 / 10 swg 640 fixing of lt stay insulator 641 concreting of stay set ( 16x 1800 mm ) 642 fixing of dead end clamps with i hook ( insulated ) 643 fixing of suspension clamp with i hook 644 fixing of pole clamps with nut and bolt 645 fixing of holding clamp for round pole with nut and bolt 646 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 647 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 648 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 649 stringing of lt abc of 3x50+1x35+1x16 sq. mm 650 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 651 1x16 mm2 xlpe insulated al. cable for energising the street light 652 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 653 fixing of end cap for lt ab cable 654 fixing of pg clamps 655 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x95+1x70+1x16 ) sq.mm. 656 erection of pcc pole, 8.5 mtr. long 657 stone pad ( 300x300x75mm ) 658 concreting of pole / support ( 0.268 cu.m. ) 659 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 660 gi wire 6 swg 661 erection of lt stay set ( 16 x 1800 mm ) 662 fixing of lt stay clamp with nut and bolt 663 erection of stay wire 7 / 10 swg 664 fixing of lt stay insulator 665 concreting of stay set ( 16x 1800 mm ) 666 dead end clamps with i hook ( insulated ) 667 fixing of suspension clamp with i hook 668 fixing of pole clamps with nut and bolt 669 holding clamp for round pole with nut and bolt 670 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 671 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 672 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 673 stringing of lt abc of 3x95+1x70+1x16 sq. mm 674 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 675 1x16 mm2 xlpe insulated al. cable for energising the street light 676 end cap for lt ab cable 677 fixing of pg clamps 678 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 679 replacement of bare conductors / damaged a.b. cable with lt ab cables ( 3x120+1x95+1x16 ) sq.mm. 680 erection of pcc pole, 8.5 mtr. long 681 stone pad ( 300x300x75mm ) 682 concreting of pole / support ( 0.268 cu.m. ) 683 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 684 gi wire 6 swg 685 erection of lt stay set ( 16 x 1800 mm ) 686 fixing of lt stay clamp with nut and bolt 687 erection of stay wire 7 / 10 swg 688 fixing of lt stay insulator 689 concreting of stay set ( 16x 1800 mm ) 690 dead end clamps with i hook ( insulated ) 691 fixing of suspension clamp with i hook 692 fixing of pole clamps with nut and bolt 693 holding clamp for round pole with nut and bolt 694 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 695 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 696 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 697 stringing of lt abc of 3x120+1x95+1x16 sq. mm 698 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 699 1x16 mm2 xlpe insulated al. cable for energising the street light 700 end cap for lt ab cable 701 fixing of pg clamps 702 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 703 feeder bifurcation ( 11 kv line ) 704 11kv new line on 11 mtr. st pole with acsr dog conductor 705 erection of 11 kv polymer disc insulator b&s type 70 kn 706 erection of disc fitting b&s type 70 kn 707 erection of 11 kv composite polymer pin insulator with nut and washers 708 fixing of 11kv smc danger board with clamp, bolts & nuts 709 fixing of 11kv smc number plate for clamp with n&b 710 erection of 11 kv stay set ( 16 x 1800 mm ) 711 fixing of 11 kv stay clamp with nut and bolt 712 erection of stay wire 7 / 10 swg 713 fixing of 11 kv stay insulator 714 concreting of stay set ( 16x 1800 mm ) 715 stringing of acsr dog conductor 716 fixing of p.g. clamp for acsr dog / raccoon 717 armour rod with ferrule for acsr dog / panther / raccoon helical performed 718 erection of 11 mtr. stp 719 erection of 13 mtr. stp 720 concreting of pole / support ( 0.44 cu.m. ) 721 concreting of pole ( 0.64 cu.m. ) 722 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 723 aluminium binding wire 6 swg 724 aluminium jointing sleeves 725 g.i. barbed wire 726 gi wire 6 swg 727 gi wire 8 swg 728 gi wire 16 swg 729 eye bolt 730 turn buckle 731 painting of st pole with red oxide paint 732 painting of st pole with aluminium paint 733 erection of 11kv e bracket with n&b 734 erection of 11kv `f bracket with n&b 735 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 736 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 737 gi top channel 125x65x6, 1525 mm long with clamp, bolts, nuts and washers 738 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 739 cross arm holding clamp with nuts & bolts 740 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 741 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 742 gi guarding angle iron 75x75x6 mm 3010 mm long 743 tree cutting compensation 744 stone pad ( 300x300x75mm ) 745 11kv new line on 8.5 mtr. pcc pole with acsr dog conductor 746 erection of 11 kv polymer disc insulator b&s type 70 kn 747 erection of disc fitting b&s type 70 kn 748 erection of 11 kv composite polymer pin insulator with nut and washers 749 fixing of 11kv smc danger board with clamp, bolts & nuts 750 fixing of 11kv smc number plate for clamp with n&b 751 erection of 11 kv stay set ( 16 x 1800 mm ) 752 fixing of 11 kv stay clamp with nut and bolt 753 erection of stay wire 7 / 10 swg 754 fixing of 11 kv stay insulator 755 concreting of stay set ( 16x 1800 mm ) 756 stringing of acsr dog conductor 757 fixing of p.g. clamp for acsr dog / raccoon 758 armour rod with ferrule for acsr dog / panther / raccoon helical performed 759 erection of pcc pole, 8.5 mtr. long 760 concreting of pole / support ( 0.268 cu.m. ) 761 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 762 aluminium binding wire 6 swg 763 aluminium jointing sleeves 764 g.i. barbed wire 765 gi wire 6 swg 766 gi wire 8 swg 767 gi wire 16 swg 768 eye bolt 769 turn buckle 770 erection of 11kv e bracket with n&b 771 erection of 11kv `f bracket with n&b 772 gi top channel 125x65mm, 3200 mm with clamp, bolts, nuts and washers 773 gi angle 65x65x6mm, 4300 mm long bracing with 4 clamps, bolts, nuts and washers 774 cross arm holding clamp with nuts & bolts 775 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 776 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 777 gi guarding angle iron 75x75x6 mm 3010 mm long 778 tree cutting compensation 779 stone pad ( 300x300x75mm ) 780 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 781 11 kv railway crossing 782 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 783 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 784 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 785 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 786 cable route marker 787 g.i. pipe 6 dia . 788 erection of 11 mtr. stp 789 stone pad ( 300x300x75mm ) 790 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 791 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 792 erection of 11 kv polymer disc insulator b&s type 70 kn 793 erection of disc fitting b&s type 70 kn 794 fixing of p.g. clamp for acsr dog / raccoon 795 fixing of 11kv smc number plate for clamp with n&b 796 fixing of 11kv smc danger board with clamp, bolts & nuts 797 g.i. barbed wire 798 aluminium binding wire 6 swg 799 painting of st pole with aluminium paint 800 painting of st pole with red oxide paint 801 erection of 11 kvstay set ( 16 x 1800 mm ) 802 fixing of 11 kv stay clamp with nut and bolt 803 erection of stay wire 7 / 10 swg 804 fixing of 11 kv stay insulator 805 concreting of stay set ( 16x 1800 mm ) 806 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 807 gi wire 6 swg 808 concreting of pole / support ( 0.44 cu.m. ) 809 railway crossing documentation, land and approval fee etc. 810 nhai / state highway crossing 811 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 812 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 813 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 814 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 815 cable route marker 816 g.i. pipe 6 dia . 817 erection of 11 mtr. stp 818 stone pad ( 300x300x75mm ) 819 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 820 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 821 erection of 11 kv polymer disc insulator b&s type 70 kn 822 disc fitting b&s type 70 kn 823 fixing of p.g. clamp for acsr dog / raccoon 824 fixing of 11kv smc number plate for clamp with n&b 825 fixing of 11kv smc danger board with clamp, bolts & nuts 826 g.i. barbed wire 827 aluminium binding wire 6 swg 828 painting of st pole with aluminium paint 829 painting of st pole with red oxide paint 830 erection of 11 kv stay set ( 16 x 1800 mm ) 831 fixing of 11 kv stay clamp with nut and bolt 832 erection of stay wire 7 / 10 swg 833 fixing of 11 kv stay insulator 834 concreting of stay set ( 16x 1800 mm ) 835 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 836 gi wire 6 swg 837 concreting of pole / support ( 0.44 cu.m. ) 838 nhai / state highway crossing documentation, land charges and approval fee etc. 839 road restoration charges 840 augumentation / reconductoring of 33 kv overhead line with dog conductor 841 stringing of acsr dog conductor 842 erection of pcc pole, 9.0 mtr. long 843 erection of 11 mtr. stp 844 concreting of pole / support ( 0.286 cu.m. ) 845 concreting of pole / support ( 0.44 cu.m. ) 846 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 847 gi wire 6 swg 848 erection of 33 kv composite polymer pin insulator with nut and washers 849 painting of st pole with aluminium paint 850 painting of st pole with red oxide paint 851 fixing of 33kv smc danger board with clamp and n&b 852 fixing of 33kv smc number plate with clampand n&b 853 stone pad ( 300x300x75mm ) 854 g.i. barbed wire 855 erection of 33kv e bracket with n&b 856 erection of 33kv f bracket with n&b 857 erection of v type cross arm for 33kv line 100x50x6 mm, gi 858 cross arm holding clamp with nuts & bolts 859 erection of 33 kv polymer disc insulator b&s type 70 kn 860 disc fitting b&s type 70 kn 861 erection of 33 kv stay set 862 fixing of 33 kv stay clamp with nut and bolt 863 erection of stay wire 7 / 8 swg 864 fixing of 33 kv stay insulator 865 concreting of 33 kv stay set 866 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 867 augmentation / reconductoring of 11kv overhead linewith acsr dog conductor 868 stringing of acsr dog conductor 869 erection of 11 kv polymer disc insulator b&s type 70 kn 870 disc fitting b&s type 70 kn 871 erection of 11 kv composite polymer pin insulator with nut and washers 872 fixing of 11kv smc danger board with clamp, bolts & nuts 873 fixing of 11kv smc number plate for clamp with n&b 874 erection of 11 kv stay set ( 16 x 1800 mm ) 875 fixing of 11 kv stay clamp with nut and bolt 876 erection of stay wire 7 / 10 swg 877 fixing of 11 kv stay insulator 878 concreting of stay set ( 16x 1800 mm ) 879 fixing of p.g. clamp for acsr dog / raccoon 880 armour rod with ferrule for acsr dog / panther / raccoon helical performed 881 erection of pcc pole, 8.5 mtr. long 882 erection of 11 mtr. stp 883 concreting of pole / support ( 0.268 cu.m. ) 884 concreting of pole / support ( 0.44 cu.m. ) 885 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 886 aluminium binding wire 6 swg 887 aluminium jointing sleeves 888 g.i. barbed wire 889 gi wire 6 swg 890 gi wire 8 swg 891 gi wire 16 swg 892 eye bolt 893 turn buckle 894 painting of st pole with red oxide paint 895 painting of st pole with aluminium paint 896 erection of 11kv `f bracket with n&b 897 cross arm holding clamp with nuts & bolts 898 erection of v type cross arm for 11kv line, 100x50x6 mm, gi 899 guarding angle 75x75x6 mm, 2200 mm long with holding clamp, packing piece, nut & bolts etc. 900 stone pad ( 300x300x75mm ) 901 dismantling of existing overhead line and transportation of materials to nearest pvvnl store. 902 11 kv agriculture feeder segregation & feeder splitting due to overloading 903 11kv new line on 8.5 mtr. pcc pole with acsr rabbit conductor 904 stringing of acsr rabbit conductor 905 erection of 11kv polymer disc insulator t&c type 45 kn 906 disc fittings t&c type 45 kn 907 erection of 11 kv composite polymer pin insulator with nut and washers 908 fixing of 11kv smc danger board with clamp, bolts & nuts 909 fixing of 11kv smc number plate for clamp with n&b 910 erection of 11 kv stay set ( 16 x 1800 mm ) 911 fixing of 11 kv stay clamp with nut and bolt 912 erection of stay wire 7 / 10 swg 913 fixing of 11 kv stay insulator 914 concreting of stay set ( 16x 1800 mm ) 915 fixing of pg clamps 916 armour rod with ferrule for acsr dog / panther / raccoon helical performed 917 erection of pcc pole, 8.5 mtr. long 918 concreting of pole / support ( 0.268 cu.m. ) 919 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 920 aluminium binding wire 6 swg 921 aluminium jointing sleeves 922 g.i. barbed wire 923 gi wire 6 swg 924 gi wire 8 swg 925 gi wire 16 swg 926 eye bolt 927 turn buckle 928 erection of 11kv e bracket with n&b 929 erection of 11kv `f bracket with n&b 930 gi top channel 100x50x2240 mm. 931 clamp with nuts & bolts for 1300 mm long gi channel 932 gi channel 100x50x6 mm. 1300 mm long with clamp, nut, bolt and washer 933 gi top channel 100x50x6, 1525 mm long 934 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 935 cross arm holding clamp with nuts & bolts 936 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 937 erection of v type cross arm for 11kv line, 65x65x6 mm, gi angle 938 guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 939 tree cutting compensation 940 stone pad ( 300x300x75mm ) 941 new lt line on acsr rabbit conductor on 8.5 mtr. pcc pole 942 erection of pcc pole, 8.5 mtr. long 943 stone pad ( 300x300x75mm ) 944 lt clamp with nut and bolt for pcc pole 945 lt shakle insulator 100x115 mm 946 bolts and nuts for shackle insulators 947 concreting of pole / support ( 0.268 cu.m. ) 948 stringing of acsr rabbit conductor 949 aluminium jointing sleeves 950 aluminium binding wire 6 swg 951 earth wire clamp 952 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 953 gi wire 6 swg 954 erection of lt stay set ( 16 x 1800 mm ) 955 fixing of lt stay clamp with nut and bolt 956 erection of stay wire 7 / 10 swg 957 fixing of lt stay insulator 958 concreting of stay set ( 16x 1800 mm ) 959 construction of new 100 kva, 11 / 0.433kv distribution transformer s / s 960 installation of 11 / 0.44 kv 100 kva transformer ( four star rating, level ii ) 961 erection of pcc pole, 8.5 mtr. long 962 stone pad ( 300x300x75mm ) 963 concreting of pole / support ( 0.268 cu.m. ) 964 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 965 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 966 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 967 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 968 gi channel 125x65x6, 1300mm ( tee off ) 969 clamp with nuts & bolts for 1300 mm long gi channel 970 erection of 11kv polymer disc insulator t&c type 45 kn 971 disc fittings t&c type 45 kn 972 erection of 11 kv composite polymer pin insulator with nut and washers 973 erection of 11kv tpmo complete set 974 erection of 11kv do fuse set ( 3 phase ) 975 erection of 11kv lightening arrestor 976 g.i. barbed wire 977 fixing of 11kv smc danger board with clamp, bolts & nuts 978 fixing of deep drawn distribution boxas per technical specificationsfor 3 ph 100 kva dtr 979 erection of lt stay set ( 16 x 1800 mm ) 980 fixing of lt stay clamp with nut and bolt 981 erection of stay wire 7 / 10 swg 982 fixing of lt stay insulator 983 concreting of stay set ( 16x 1800 mm ) 984 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 985 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 986 lt pvc cable3.5x150 / 70sq.mm. 987 acsr weasel conductor 988 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 989 gi wire 6 swg 990 gi strip 25x3 mm 991 gi angle 100x50x2028mm ( fordistribution box ) ) 992 al. crimping lugs 150 sq.mm. 993 al. crimping lugs 70 sq.mm. 994 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 995 construction of new 63 kva, 11 / 0.433kv distribution transformer s / s 996 installation of11 / 0.44 kv 63 kva transformer ( four star rating, level ii ) 997 erection of pcc pole, 8.5 mtr. long 998 stone pad ( 300x300x75mm ) 999 concreting of pole / support ( 0.268 cu.m. ) 1000 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1001 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 1002 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1003 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 1004 gi channel 125x65x6, 1300mm ( tee off ) 1005 clamp with nuts & bolts for 1300 mm long gi channel 1006 erection of 11kv polymer disc insulator t&c type 45 kn 1007 disc fittings t&c type 45 kn 1008 erection of 11 kv composite polymer pin insulator with nut and washers 1009 erection of 11kv tpmo complete set 1010 erection of 11kv do fuse set ( 3 phase ) 1011 erection of 11kv lightening arrestor 1012 g.i. barbed wire 1013 fixing of 11kv smc danger board with clamp, bolts & nuts 1014 fixing of deep drawn distribution box as per technical specifications for 3 ph 63 kva dtr 1015 erection of lt stay set ( 16 x 1800 mm ) 1016 fixing of lt stay clamp with nut and bolt 1017 erection of stay wire 7 / 10 swg 1018 fixing of lt stay insulator 1019 concreting of stay set ( 16x 1800 mm ) 1020 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 1021 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 1022 lt pvc cable3.5x70 / 35sq.mm. 1023 acsr weasel conductor 1024 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1025 gi wire 6 swg 1026 gi strip 25x3 mm 1027 gi angle 100x50x2028mm ( fordistribution box ) ) 1028 al. crimping lugs 70 sq.mm. 1029 al. crimping lugs 35 sq.mm. 1030 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 1031 construction of new 25 kva, 11 / 0.433kv distribution transformer s / s 1032 installation of11 / 0.44 kv 25 kva transformer ( four star rating, level ii ) 1033 erection of pcc pole, 8.5 mtr. long 1034 stone pad ( 300x300x75mm ) 1035 concreting of pole / support ( 0.268 cu.m. ) 1036 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1037 gi channel 100x50x2028mm ( for tpmo, la and fuse set ) 1038 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1039 gi angle 75x75x6 mm, 2028 mm long with clamp for t / f base 1040 gi channel 125x65x6, 1300mm ( tee off ) 1041 clamp with nuts & bolts for 1300 mm long gi channel 1042 erection of 11kv polymer disc insulator t&c type 45 kn 1043 disc fittings t&c type 45 kn 1044 erection of 11 kv composite polymer pin insulator with nut and washers 1045 erection of 11kv tpmo complete set 1046 erection of 11kv do fuse set ( 3 phase ) 1047 erection of 11kv lightening arrestor 1048 g.i. barbed wire 1049 fixing of 11kv smc danger board with clamp, bolts & nuts 1050 fixing of deep drawn distribution boxas per technical specifications for 3 ph 25 kva dtr 1051 erection of lt stay set ( 16 x 1800 mm ) 1052 fixing of lt stay clamp with nut and bolt 1053 erection of stay wire 7 / 10 swg 1054 fixing of lt stay insulator 1055 concreting of stay set ( 16x 1800 mm ) 1056 chemical pipe earthing ( 80 mm dia, 3 m long pipe ) 1057 aluminium l piece of size 400x60x10 mm for lt bushing rod of transformer 1058 lt xlpe insulated unarmoured 4x25 sq. mm.cable 1059 acsr weasel conductor 1060 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1061 gi wire 6 swg 1062 gi strip 25x3 mm 1063 gi angle 100x50x2028mm ( fordistribution box ) ) 1064 al. crimping lugs 25 sq.mm. 1065 extra for al. tape , binding wire, jointing sleeves, pg clamps etc. 1066 installation of 11 kv outgoing vcb for feeder segreration 1067 installation of 11kv outgoing ctr 400 / 200 / 5a 350 mva 1068 rearrangement for connecting new 11 kv switchgear with existing 11 kv switchgears ( adopter panel ) 1069 11kv 3x185 mm2xlpe cable 1070 laying of 11 kv cable including cost of sand & bricks 1071 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1072 heat shrinkable indoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1073 erection of 11 mtr. stp 1074 gi top channel 100x50x2240 mm. 1075 stone pad ( 300x300x75mm ) 1076 erection of 11 kv polymer disc insulator b&s type 70 kn 1077 disc fitting b&s type 70 kn 1078 erection of 11 kv composite polymer pin insulator with nut and washers 1079 fixing of p.g. clamp for acsr dog / raccoon 1080 erection of 11kv e bracket with n&b 1081 fixing of 11kv smc number plate for clamp with n&b 1082 fixing of 11kv smc danger board with clamp, bolts & nuts 1083 gi channel 125x65x2028 mm long ( dropper for fuse set ) 1084 holding clamps for top channel tpmo & fuse set etc. with nuts, bolts & washers 1085 erection of 11kv tpmo complete set 1086 erection of 11kv do fuse set ( 3 phase ) 1087 erection of 11kv lightening arrestor 1088 g.i. barbed wire 1089 aluminium binding wire 6 swg 1090 painting of st pole with aluminium paint 1091 painting of st pole with red oxide paint 1092 erection of 11 kv stay set ( 16 x 1800 mm ) 1093 fixing of 11 kv stay clamp with nut and bolt 1094 erection of stay wire 7 / 10 swg 1095 fixing of 11 kv stay insulator 1096 concreting of stay set ( 16x 1800 mm ) 1097 concreting of pole / support ( 0.44 cu.m. ) 1098 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1099 gi strip 50x6 mm 1100 gi wire 6 swg 1101 g.i. pipe 6 dia . 1102 control room extension 1103 extension of existing substationcontrol room building. ( as per annexure attached in tender documents. ) 1104 11 kv railway crossing 1105 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1106 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1107 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1108 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1109 cable route marker 1110 g.i. pipe 6 dia . 1111 erection of 11 mtr. stp 1112 stone pad ( 300x300x75mm ) 1113 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1114 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1115 erection of 11 kv polymer disc insulator b&s type 70 kn 1116 disc fitting b&s type 70 kn 1117 fixing of p.g. clamp for acsr dog / raccoon 1118 fixing of 11kv smc number plate for clamp with n&b 1119 fixing of 11kv smc danger board with clamp, bolts & nuts 1120 g.i. barbed wire 1121 aluminium binding wire 6 swg 1122 painting of st pole with aluminium paint 1123 painting of st pole with red oxide paint 1124 erection of 11 kvstay set ( 16 x 1800 mm ) 1125 fixing of 11 kv stay clamp with nut and bolt 1126 erection of stay wire 7 / 10 swg 1127 fixing of 11 kv stay insulator 1128 concreting of stay set ( 16x 1800 mm ) 1129 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1130 gi wire 6 swg 1131 concreting of pole / support ( 0.44 cu.m. ) 1132 railway crossing documentation, land and approval fee etc. 1133 nhai / state highway crossing 1134 heat shrinkable outdoor type termination kit suitable for 11kv xlpe 3x185 sq.mm. cable size 1135 hdpe pipe for cable laying ( pipe to be laid by hdd method ) ( for railway crossing / road crossing ) 1136 digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of 33 kv & 11 kv xlpe cables 1137 laying of 3x185 sq. mm. 11 kv xlpe insulated cable underground in hdpe pipe / trenches / riser 1138 cable route marker 1139 g.i. pipe 6 dia . 1140 erection of 11 mtr. stp 1141 stone pad ( 300x300x75mm ) 1142 gi angle 65x65x6 mm, 2700 mm long bracing complete with 4 clamps, nut, bolt and washers 1143 gi top channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 1144 erection of 11 kv polymer disc insulator b&s type 70 kn 1145 disc fitting b&s type 70 kn 1146 fixing of p.g. clamp for acsr dog / raccoon 1147 fixing of 11kv smc number plate for clamp with n&b 1148 fixing of 11kv smc danger board with clamp, bolts & nuts 1149 g.i. barbed wire 1150 aluminium binding wire 6 swg 1151 painting of st pole with aluminium paint 1152 painting of st pole with red oxide paint 1153 erection of 11 kv stay set ( 16 x 1800 mm ) 1154 fixing of 11 kv stay clamp with nut and bolt 1155 erection of stay wire 7 / 10 swg 1156 fixing of 11 kv stay insulator 1157 concreting of stay set ( 16x 1800 mm ) 1158 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1159 gi wire 6 swg 1160 concreting of pole / support ( 0.44 cu.m. ) 1161 nhai / state highway crossing documentation, land charges and approval fee etc. 1162 road restoration charges 1163 requirement of extra ab cable for new additional ckt at dts 1164 construction ofnew lt line on ( 3x50 + 1x35 +1x16 ) sq. mm lt abc cable 1165 erection of pcc pole, 8.5 mtr. long 1166 erection of 11 mtr. stp 1167 stone pad ( 300x300x75mm ) 1168 concreting of pole / support ( 0.268 cu.m. ) 1169 concreting of pole / support ( 0.44 cu.m. ) 1170 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1171 gi wire 6 swg 1172 erection of lt stay set ( 16 x 1800 mm ) 1173 fixing of lt stay clamp with nut and bolt 1174 erection of stay wire 7 / 10 swg 1175 fixing of lt stay insulator 1176 concreting of stay set ( 16x 1800 mm ) 1177 dead end clamps with i hook ( insulated ) 1178 fixing of suspension clamp with i hook 1179 fixing of pole clamps with nut and bolt 1180 lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1181 lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1182 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1183 stringing of lt abc of 3x50+1x35+1x16 sq. mm 1184 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1185 end cap for lt ab cable 1186 fixing of pg clamps 1187 1x16 mm2 xlpe insulated al. cable for energising the street light 1188 construction of new lt line on ( 3x95 + 1x70 +1x16 ) sq. mm lt abc cable 1189 erection of pcc pole, 8.5 mtr. long 1190 erection of 11 mtr. stp 1191 stone pad ( 300x300x75mm ) 1192 concreting of pole / support ( 0.268 cu.m. ) 1193 concreting of pole / support ( 0.44 cu.m. ) 1194 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1195 gi wire 6 swg 1196 erection of lt stay set ( 16 x 1800 mm ) 1197 fixing of lt stay clamp with nut and bolt 1198 erection of stay wire 7 / 10 swg 1199 fixing of lt stay insulator 1200 concreting of stay set ( 16x 1800 mm ) 1201 dead end clamps with i hook ( insulated ) 1202 fixing of suspension clamp with i hook 1203 fixing of pole clamps with nut and bolt 1204 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1205 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1206 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1207 stringing of lt abc of 3x95+1x70+1x16 sq. mm 1208 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1209 end cap for lt ab cable 1210 fixing of pg clamps 1211 1x16 mm2 xlpe insulated al. cable for energising the street light 1212 construction of new lt line on ( 3x120 + 1x95 +1x16 ) sq. mm lt abc cable 1213 erection of pcc pole, 8.5 mtr. long 1214 erection of 11 mtr. stp 1215 stone pad ( 300x300x75mm ) 1216 concreting of pole / support ( 0.268 cu.m. ) 1217 concreting of pole / support ( 0.44 cu.m. ) 1218 fixing of earthing coil ( coil of 115 turns of 50 mm dia and 2.5mtrs lead of 4.0mm gi wire ) 1219 gi wire 6 swg 1220 erection of lt stay set ( 16 x 1800 mm ) 1221 fixing of lt stay clamp with nut and bolt 1222 erection of stay wire 7 / 10 swg 1223 fixing of lt stay insulator 1224 concreting of stay set ( 16x 1800 mm ) 1225 dead end clamps with i hook ( insulated ) 1226 fixing of suspension clamp with i hook 1227 fixing of pole clamps with nut and bolt 1228 fixing of lt insulation piercing connectors of 120 50 sq. mm 50 35 sq. mm size for energizing distribution kiosk / box 1229 fixing of lt insulation piercing connectors ( 16 sq. mm 16 sq. mm ) suitable for street light connection 1230 fixing ofdeep drawn lt distribution boxes / kiosk, 3 phase on the lt poles including all clamps & material required for mounting connections & sealing and suitable lock and key arrangment 1231 stringing of lt abc of 3x120+1x95+1x16 sq. mm 1232 1x35 mm2 xlpe insulated al. cable for energising the distribution boxes / kiosks. 1233 end cap for lt ab cable 1234 fixing of pg clamps 1235 1x16 mm2 xlpe insulated al. cable for energising the street light 1236 additional items that may be required for completion of work 1237 3x120 sq. mm 11 kv ab cable 1238 11kv polymer disc insulator with fitting for 11 kvabc 1239 11kv polymer disc insulators with i hook 1240 erection & concreting of extra stud pole complete with clamps, 1241 gi channel 100 x 50 x 3200 mmunit with mounting clamps, nut, bolt and washers 1242 gi angle 50 x 50 x 6 mm, 3200 mm long with 2 nos.clamps, required nut, bolt and washers 1243 gi angle65x65x6mm, 450 mm bracing set complete with clamps, nut, bolt and washers 1244 lt xlpe insulated unarmoured 1x50 sq. mm. cable 1245 heat shrinkable outdoor type termination kit suitable for 33kv xlpe 3x300 sq. mm. cable size 1246 heat shrinkable 1 ph. termination kit outdoor for 11 kv 3x120 sq. mm. ab cable 1247 laying of 3x300 sq. mm. 33 kv xlpe insulated cable underground in hdpe pipe or trenches ( for railway / road crossing ) 1248 drilling & laying of ht underground cable using hdd method without using hdpe pipe 1249 loop guard complete, 3 phase 1250 spacers lt pvc 1251 mid span jointing sleeves ( 95 sq. mm ) 1252 lt insulation piercing connectors of 95 / 50 sq. mm 70 / 35 sq. mm ( for messenger wire jumpering & energizing db neutral ) 1253 fixing of on / off switch for street light connections 1254 mounting of cable on dp structure ( including loop and riser ) 1255 height raising channel 100x50, 2240 mm long 1256 back clamp for height raising channel holding clamps with bolts & nuts 1257 cable jointing kit straight through ( 3x185 sqmm ) 1258 cable jointing kit straight through ( 3x300sqmm ) 1259 extra prefabricated gi items like clamp, channel, angle with nut & bolt...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32081345 development of distribution infrastructure at aligarh zone ( electricity distribution circles etah & kasganj [ district etah & kasganj ] ) of uttar pradeshstate under the revamped reforms based and results linked, distribution sector scheme 1 supply of items 2 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 3 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 4 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 5 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 6 stone pad ( 300x300x75mm ) 7 1 core ( al. ) 120mm2 lt armoured xlpe cable 8 1 core ( al. ) 95mm2 lt armoured xlpe cable 9 1 core ( al. ) 50mm2 lt armoured xlpe cable 10 1 core ( al. ) 25mm2 lt armoured xlpe cable 11 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 12 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 13 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 14 armoured service cable 2cx4 sqmm for single phase consumer 15 armoured service cable 2cx6 sqmm for single phase consumer 16 armoured service cable 4cx10 sqmm for three phase consumer 17 armoured service cable 4cx16 sqmm for three phase consumer 18 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 19 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 20 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 21 lt pvc cable 3.5x150 sq mm 22 lt pvc cable 3.5x70 sq mm 23 lt pvc cable 4x16 sq mm 24 l.t. pvc cable 10 sq. mm single core 25 lt pvc cable 3.5x400 sq mm 26 acsr rabbit conductor 27 aluminium binding wire 6 swg 28 jointing sleave 29 mid span joint 120mm2 30 acsr rabbit conductor jumpering works 31 acsr weasel conductor jumpering works 32 11 kv danger board with clamp and nuts & bolts 33 11 kv number plate with clamp and nuts & bolts 34 11kv fuse set ( drop out ) with clamps 35 11kv tpmo with fixing clamps 36 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 37 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 38 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 39 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 40 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 41 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 42 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 43 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 44 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 45 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 46 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 47 4 core lt mcb with box 48 copper l piece 50x225x10mm 49 copper l piece 50x225x12mm 50 al leg long barrel off size 51 9 kv la , 5 ka ( distribution class ) 52 9 kv la , 10 ka ( station class ) 53 earthing coil connected with nutbolt using charchol and salt 54 gi flat 50x6 for earthing 55 gi flat 25x3 for earthing 56 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 57 gi pipe 6 diameter with clamps 58 g.i. barbed wire 59 g.i. wire no. 16 swg for binding 60 g.i. wire 6 swg 61 g.i. wire 8 swg 62 33 kv g.i. pin ( 10 kn ) with nuts & washers 63 11 kv disc fitting b & s type ( 45 kn ) 64 11 kv disc. insulators b&s type 45 kn ( polymer type ) 65 11 kv pin insulator polymer type as per ts 66 33 kv pin insulator 67 lt shackle insulator 68 insulating piercing connector ( 50 150 sq.mm ) 69 insulating piercing connector ( 16 150 sq.mm ) 70 dead end clamp ( insulated ) 71 end cap for ab cable 72 suspension clamps ( insulated ) 73 pole clamps with with i hook & nut & bolts for laying abc 74 d straps 75 insulation mastic tape ( 2inc x 10 feet ) . 76 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 77 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 78 aluminium paint 79 red oxide paint 80 smart tvm meter compatible with system ( ami ) complete set 81 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 82 crimping type heavy duty aluminium lugs suitable for connection pvc cables 83 armour rod with ferrules for acsr rabbit / weasel helical performed 84 cable route marker 85 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 86 pg clamp for rabbit 87 gi stay wire 7 / 10 swg 88 gi stay wire 7 / 8 swg 89 ht guy insulator 90 lt guy insulator 91 33 kv stay complete ( gi stay rod 20x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 92 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 93 turn buckle 94 ht stay clamp as per approved drawing 33 kv 95 ht stay clamp as per approved drawing 11 kv 96 lt stay clamp as per approved drawing 97 11 kv cross arm holding clamps with bolts & nuts 98 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 99 33 kv cross arm holding clamps with bolts & nuts 100 33 kv steel x arm v type ( gi channel 100 x 50 x 6 mm ) 101 angle for vertical arml50x50x6 ( type a ) 900mm 102 angle for vertical arml50x50x6 ( type b ) 900mm 103 top clamp for vertical arm l 50x6 ( type a ) 435 mm 104 top clamp for vertical arm l 50x6 ( type b ) 435 mm 105 bottom clamp for vertical arm l 50x6 ( type a ) 507 mm 106 bottom clamp for vertical arm l 50x6 ( type b ) 507 mm 107 clamp for top channel with nut bolt 108 clamps for lt t off with bolts & nuts 109 e bracket for 11 kv line 110 eye bolt 111 f bracket for 11 kv line 112 f bracket for 33 kv line 113 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 114 holding clamps for top channel, gi channel & gi angle with bolts & nuts 115 m.s. top channel 100x50x6 mm., 2240 mmlong 116 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 117 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 118 m.s. top channel 125x65x6 mm., 2240 mmlong 119 tee off channel 100x50x1300 mm with clamp, nut & bolt 120 clamps for dist. box ( 40x6 mm ) 121 clamps for t / f ( 75x8 mm gi flat ) . 122 gi. guarding angle 75x75x6 mm 3010 mm long with clamp 123 height raising channel 100x50, 2240 mm long 124 back clamp for height raising channel holding clamps with bolts & nuts 125 gi channel 100x50x6 mm. 1300 mm long 126 gi channel clamp with nuts & bolts 127 gi angle iron 50x50x6 mm bracing with 4 clamps 128 gi channel 125x65 mm 129 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 130 gi channel 75x75x6 mm &bolt and nut ( t / f base support ) 131 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 132 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 133 cable jointing kit straight through ( 3x185 ) 134 extra prefabricated items like clamp , channel, angle with nut bolt 135 erection part 136 conversion of existing service cable to new armoured service cable with all required accessories like j pipe , shaddle , conduit pipe , clamp , gi wire , reel insulator , earthing bolt and lugs etc. ( complete work in all respect ) and removing and shifting of existing material to client store 137 armoured service cable 2cx4 sqmm for single phase consumer 138 armoured service cable 2cx6 sqmm for single phase consumer 139 armoured service cable 4cx10 sqmm for three phase consumer 140 armoured service cable 4cx16 sqmm for three phase consumer 141 erection, testingand commissioning of replacement oflt bare conductor with ab cables ( complete work in all respect ) 142 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 143 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 144 stone pad ( 300x300x75mm ) 145 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 146 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 147 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 148 pole clamps with with i hook & nut & bolts for laying abc 149 dead end clamp ( insulated ) 150 suspension clamps ( insulated ) 151 insulating piercing connector ( 16 150 sq.mm ) 152 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 153 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 154 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 155 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 156 earthing coil connected with nutbolt using charchol and salt 157 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 158 lt guy insulator 159 gi stay wire 7 / 10 swg 160 lt stay clamp as per approved drawing 161 removing and shifting of existing material to client store 162 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 163 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 164 erection, testingand commissioning of replacement ofab cable ( damage ) with ab cables ( complete work in all respect ) 165 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 166 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 167 stone pad ( 300x300x75mm ) 168 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 169 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 170 pole clamps with with i hook & nut & bolts for laying abc 171 dead end clamp ( insulated ) 172 suspension clamps ( insulated ) 173 insulating piercing connector ( 16 150 sq.mm ) 174 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 175 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 176 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 177 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 178 earthing coil connected with nutbolt using charchol and salt 179 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 180 lt guy insulator 181 gi stay wire 7 / 10 swg 182 lt stay clamp as per approved drawing 183 removing and shifting of existing material to client store 184 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 185 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 186 erection, testingand commissioning of replacement of lt line with xlpe armoured cables ( complete work in all respect ) 187 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 188 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 189 stone pad ( 300x300x75mm ) 190 angle for vertical arml50x50x6 ( type a ) 900mm 191 top clamp for vertical arm l 50x6 ( type a ) 435 mm 192 bottom clamp for vertical arm l 50x6 ( type a ) 507 mm 193 angle for vertical arml50x50x6 ( type b ) 900mm 194 top clamp for vertical arm l 50x6 ( type b ) 435 mm 195 bottom clamp for vertical arm l 50x6 ( type b ) 507 mm 196 lt shackle insulator 197 d straps 198 1 core ( al. ) 120mm2 lt armoured xlpe cable 199 1 core ( al. ) 95mm2 lt armoured xlpe cable 200 1 core ( al. ) 50mm2 lt armoured xlpe cable 201 1 core ( al. ) 25mm2 lt armoured xlpe cable 202 mid span joint 120mm2 203 insulating piercing connector ( 50 150 sq.mm ) 204 insulation mastic tape ( 2inc x 10 feet ) . 205 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 206 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 207 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 208 earthing coil connected with nutbolt using charchol and salt 209 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 210 lt guy insulator 211 gi stay wire 7 / 10 swg 212 lt stay clamp as per approved drawing 213 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 214 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 215 removing and shifting of existing material to client store 216 survey , erection, testingand commissioning of 11 kv line ( feeder spliting due to over loading ) on 8.5 mtr pcc pole 115.6 ckm and 11 mtr stp pole 151.4 ckm ( complete work in all respect ) 217 route survey and pole spotting for 11 kv line 218 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 219 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 220 acsr rabbit conductor 221 stone pad ( 300x300x75mm ) 222 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 223 11 kv cross arm holding clamps with bolts & nuts 224 f bracket for 11 kv line 225 m.s. top channel 100x50x6 mm., 2240 mmlong 226 clamp for top channel with nut bolt 227 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 228 e bracket for 11 kv line 229 11 kv pin insulator polymer type as per ts 230 11 kv disc. insulators b&s type 45 kn ( polymer type ) 231 11 kv disc fitting b & s type ( 45 kn ) 232 pg clamp for rabbit 233 aluminium binding wire 6 swg 234 jointing sleave 235 11 kv danger board with clamp and nuts & bolts 236 g.i. barbed wire 237 aluminium paint 238 red oxide paint 239 earthing coil connected with nutbolt using charchol and salt 240 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 241 ht guy insulator 242 gi stay wire 7 / 10 swg 243 ht stay clamp as per approved drawing 11 kv 244 11 kv number plate with clamp and nuts & bolts 245 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 246 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 247 erection, testingand commissioning of 11 kv vcb with complete assoceries as apporoved drawing and tecchanical specifiactions ( complete work in all respect ) 248 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 249 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 250 smart tvm meter compatible with system ( ami ) complete set 251 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 252 gi flat 50x6 for earthing 253 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 254 stone pad ( 300x300x75mm ) 255 m.s. top channel 100x50x6 mm., 2240 mmlong 256 clamp for top channel with nut bolt 257 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 258 11 kv disc. insulators b&s type 45 kn ( polymer type ) 259 11 kv disc fitting b & s type ( 45 kn ) 260 pg clamp for rabbit 261 11 kv danger board with clamp and nuts & bolts 262 g.i. barbed wire 263 earthing coil connected with nutbolt using charchol and salt 264 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 265 ht guy insulator 266 gi stay wire 7 / 10 swg 267 ht stay clamp as per approved drawing 11 kv 268 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 269 survey , erection, testingand commissioning of 11 kv line ( feeder sagrigation ) ( complete work in all respect ) 270 route survey and pole spotting for 11 kv line 271 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 272 acsr rabbit conductor 273 stone pad ( 300x300x75mm ) 274 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 275 11 kv cross arm holding clamps with bolts & nuts 276 f bracket for 11 kv line 277 m.s. top channel 100x50x6 mm., 2240 mmlong 278 clamp for top channel with nut bolt 279 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 280 e bracket for 11 kv line 281 11 kv pin insulator polymer type as per ts 282 11 kv disc. insulators b&s type 45 kn ( polymer type ) 283 11 kv disc fitting b & s type ( 45 kn ) 284 pg clamp for rabbit 285 aluminium binding wire 6 swg 286 jointing sleave 287 11 kv danger board with clamp and nuts & bolts 288 g.i. barbed wire 289 earthing coil connected with nutbolt using charchol and salt 290 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 291 ht guy insulator 292 gi stay wire 7 / 10 swg 293 ht stay clamp as per approved drawing 11 kv 294 11 kv number plate with clamp and nuts & bolts 295 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 296 erection, testingand commissioning of 11 kv vcb with complete assoceries as apporoved drawing and tecchanical specifiactions ( feeder segrigation ) ( complete work in all respect ) 297 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 298 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 299 smart tvm meter compatible with system ( ami ) complete set 300 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 301 gi flat 50x6 for earthing 302 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 303 stone pad ( 300x300x75mm ) 304 m.s. top channel 100x50x6 mm., 2240 mmlong 305 clamp for top channel with nut bolt 306 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 307 11 kv disc. insulators b&s type 45 kn ( polymer type ) 308 11 kv disc fitting b & s type ( 45 kn ) 309 pg clamp for rabbit 310 11 kv danger board with clamp and nuts & bolts 311 g.i. barbed wire 312 earthing coil connected with nutbolt using charchol and salt 313 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 314 ht guy insulator 315 gi stay wire 7 / 10 swg 316 ht stay clamp as per approved drawing 11 kv 317 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 318 erection, testingand commissioning of 11 kv nh crossing ( complete work in all respect ) 319 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 320 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 321 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 322 gi pipe 6 diameter with clamps 323 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 324 gi angle iron 50x50x6 mm bracing with 4 clamps 325 m.s. top channel 100x50x6 mm., 2240 mmlong 326 clamp for top channel with nut bolt 327 g.i. barbed wire 328 stone pad ( 300x300x75mm ) 329 11 kv pin insulator polymer type as per ts 330 11 kv disc. insulators b&s type 45 kn ( polymer type ) 331 11 kv disc fitting b & s type ( 45 kn ) 332 pg clamp for rabbit 333 e bracket for 11 kv line 334 11 kv danger board with clamp and nuts & bolts 335 aluminium paint 336 red oxide paint 337 earthing coil connected with nutbolt using charchol and salt 338 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 339 ht guy insulator 340 gi stay wire 7 / 10 swg 341 ht stay clamp as per approved drawing 11 kv 342 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 343 cable laying including cost of material eg. , bricks, sand, clamps etc. 344 erection, testingand commissioning of 11 kv railway crossing ( complete work in all respect ) 345 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 346 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 347 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 348 gi pipe 6 diameter with clamps 349 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 350 gi angle iron 50x50x6 mm bracing with 4 clamps 351 m.s. top channel 100x50x6 mm., 2240 mmlong 352 clamp for top channel with nut bolt 353 g.i. barbed wire 354 stone pad ( 300x300x75mm ) 355 11 kv pin insulator polymer type as per ts 356 11 kv disc. insulators b&s type 45 kn ( polymer type ) 357 11 kv disc fitting b & s type ( 45 kn ) 358 pg clamp for rabbit 359 e bracket for 11 kv line 360 11 kv danger board with clamp and nuts & bolts 361 aluminium paint 362 red oxide paint 363 earthing coil connected with nutbolt using charchol and salt 364 9 kv la , 10 ka ( station class ) 365 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 366 ht guy insulator 367 gi stay wire 7 / 10 swg 368 ht stay clamp as per approved drawing 11 kv 369 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 370 cable laying including cost of material eg. , bricks, sand, clamps etc. 371 erection, testingand commissioning of 11 kv line crossing by 33kv lines on stp 13 mtr with cradle guarding ( complete work in all respect ) 372 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 373 33 kv steel x arm v type ( gi channel 100 x 50 x 6 mm ) 374 33 kv cross arm holding clamps with bolts & nuts 375 33 kv pin insulator 376 33 kv g.i. pin ( 10 kn ) with nuts & washers 377 gi. guarding angle 75x75x6 mm 3010 mm long with clamp 378 f bracket for 33 kv line 379 turn buckle 380 g.i. wire 6 swg 381 g.i. wire 8 swg 382 g.i. wire no. 16 swg for binding 383 eye bolt 384 armour rod with ferrules for acsr rabbit / weasel helical performed 385 stone pad ( 300x300x75mm ) 386 11 kv danger board with clamp and nuts & bolts 387 11 kv number plate with clamp and nuts & bolts 388 g.i. barbed wire 389 red oxide paint 390 aluminium paint 391 aluminium binding wire 6 swg 392 earthing coil connected with nutbolt using charchol and salt 393 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 394 33 kv stay complete ( gi stay rod 20x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 395 ht guy insulator 396 gi stay wire 7 / 8 swg 397 ht stay clamp as per approved drawing 33 kv 398 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.64 cmt ( 13 meter stp ) as per approved drawing 399 erection, testingand commissioning of lt line crossing by 11 kv lines on stp 11 mtr with cradle guarding ( complete work in all respect ) 400 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 401 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 402 11 kv cross arm holding clamps with bolts & nuts 403 11 kv pin insulator polymer type as per ts 404 f bracket for 11 kv line 405 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 406 turn buckle 407 g.i. wire 6 swg 408 g.i. wire 8 swg 409 g.i. wire no. 16 swg for binding 410 eye bolt 411 armour rod with ferrules for acsr rabbit / weasel helical performed 412 stone pad ( 300x300x75mm ) 413 11 kv danger board with clamp and nuts & bolts 414 11 kv number plate with clamp and nuts & bolts 415 g.i. barbed wire 416 red oxide paint 417 aluminium paint 418 aluminium binding wire 6 swg 419 earthing coil connected with nutbolt using charchol and salt 420 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 421 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 422 ht guy insulator 423 gi stay wire 7 / 8 swg 424 ht stay clamp as per approved drawing 11 kv 425 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 426 erection, testingand commissioning of ug cable 11 kv line ( complete work in all respect ) 427 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 428 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 429 cable jointing kit straight through ( 3x185 ) 430 gi pipe 6 diameter with clamps 431 cable route marker 432 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 433 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 434 gi angle iron 50x50x6 mm bracing with 4 clamps 435 m.s. top channel 100x50x6 mm., 2240 mmlong 436 clamp for top channel with nut bolt 437 g.i. barbed wire 438 stone pad ( 300x300x75mm ) 439 11 kv pin insulator polymer type as per ts 440 11 kv disc. insulators b&s type 45 kn ( polymer type ) 441 11 kv disc fitting b & s type ( 45 kn ) 442 pg clamp for rabbit 443 e bracket for 11 kv line 444 11 kv danger board with clamp and nuts & bolts 445 aluminium paint 446 red oxide paint 447 earthing coil connected with nutbolt using charchol and salt 448 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 449 ht guy insulator 450 gi stay wire 7 / 10 swg 451 ht stay clamp as per approved drawing 11 kv 452 road restoration chages forroad crossing 453 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 454 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 25 kva , 63 kva and 100 kva ( complete work in all respect ) 455 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 456 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 457 stone pad ( 300x300x75mm ) 458 clamps for lt t off with bolts & nuts 459 holding clamps for top channel, gi channel & gi angle with bolts & nuts 460 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 461 m.s. top channel 125x65x6 mm., 2240 mmlong 462 11 kv disc. insulators b&s type 45 kn ( polymer type ) 463 11 kv disc fitting b & s type ( 45 kn ) 464 tee off channel 100x50x1300 mm with clamp, nut & bolt 465 11 kv pin insulator polymer type as per ts 466 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 467 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 468 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 469 11kv tpmo with fixing clamps 470 11kv fuse set ( drop out ) with clamps 471 9 kv la , 5 ka ( distribution class ) 472 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 473 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 474 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 475 lt pvc cable 4x16 sq mm 476 lt pvc cable 3.5x70 sq mm 477 lt pvc cable 3.5x150 sq mm 478 11 kv danger board with clamp and nuts & bolts 479 g.i. barbed wire 480 acsr rabbit conductor jumpering works 481 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 482 ht guy insulator 483 gi stay wire 7 / 10 swg 484 ht stay clamp as per approved drawing 11 kv 485 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 486 gi flat 25x3 for earthing 487 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 488 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 10 kva and 16 kva ( complete work in all respect ) 489 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 490 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 491 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 492 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 493 clamps for dist. box ( 40x6 mm ) 494 clamps for t / f ( 75x8 mm gi flat ) . 495 acsr weasel conductor jumpering works 496 11 kv pin insulator polymer type as per ts 497 eye bolt 498 l.t. pvc cable 10 sq. mm single core 499 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 500 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 501 ht guy insulator 502 gi stay wire 7 / 10 swg 503 ht stay clamp as per approved drawing 11 kv 504 relocation , testing and commissioningof 250 kva , 11 / 0.433 kv three phase transformer sub station ( complete work in all respect ) 505 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 506 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 507 stone pad ( 300x300x75mm ) 508 holding clamps for top channel, gi channel & gi angle with bolts & nuts 509 m.s. top channel 125x65x6 mm., 2240 mmlong 510 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 511 gi channel 75x75x6 mm &bolt and nut ( t / f base support ) 512 11 kv disc. insulators b&s type 45 kn ( polymer type ) 513 11 kv disc fitting b & s type ( 45 kn ) 514 tee off channel 100x50x1300 mm with clamp, nut & bolt 515 clamps for lt t off with bolts & nuts 516 11 kv pin insulator polymer type as per ts 517 11kv tpmo with fixing clamps 518 11kv fuse set ( drop out ) with clamps 519 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 520 copper l piece 50x225x10mm 521 copper l piece 50x225x12mm 522 lt pvc cable 3.5x400 sq mm 523 al leg long barrel off size 524 4 core lt mcb with box 525 11 kv danger board with clamp and nuts & bolts 526 g.i. barbed wire 527 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 528 ht guy insulator 529 gi stay wire 7 / 10 swg 530 ht stay clamp as per approved drawing 11 kv 531 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 532 gi flat 50x6 for earthing 533 gi channel 125x65 mm 534 9 kv la , 5 ka ( distribution class ) 535 crimping type heavy duty aluminium lugs suitable for connection pvc cables 536 pg clamp for rabbit 537 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 538 dts plinth foundation 539 dismentaling of distribution transformer along with accessories. relocate the dt only at new location , testing , comissioning and charging and other shifting to store. 540 erection, testingand commissioning of new lt line with ab cable ( complete work in all respect ) 541 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 542 stone pad ( 300x300x75mm ) 543 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 544 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 545 pole clamps with with i hook & nut & bolts for laying abc 546 dead end clamp ( insulated ) 547 suspension clamps ( insulated ) 548 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 549 insulating piercing connector ( 16 150 sq.mm ) 550 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 551 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 552 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 553 earthing coil connected with nutbolt using charchol and salt 554 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 555 lt guy insulator 556 gi stay wire 7 / 10 swg 557 lt stay clamp as per approved drawing 558 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 559 erection, testingand commissioning of 11kv line guarding ( complete work in all respect ) 560 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 561 height raising channel 100x50, 2240 mm long 562 back clamp for height raising channel holding clamps with bolts & nuts 563 g.i. wire 6 swg 564 g.i. wire 8 swg 565 turn buckle 566 eye bolt 567 g.i. wire no. 16 swg for binding 568 earthing coil connected with nutbolt using charchol and salt 569 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 570 ht guy insulator 571 gi stay wire 7 / 10 swg 572 ht stay clamp as per approved drawing 11 kv 573 erection, testingand commissioning of tee of channel ( complete work in all respect ) 574 gi channel 100x50x6 mm. 1300 mm long 575 gi channel clamp with nuts & bolts 576 11 kv disc. insulators b&s type 45 kn ( polymer type ) 577 11 kv disc fitting b & s type ( 45 kn ) 578 11 kv pin insulator polymer type as per ts 579 pg clamp for rabbit 580 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 581 ht guy insulator 582 gi stay wire 7 / 10 swg 583 ht stay clamp as per approved drawing 11 kv 584 control room building extention work ( complete work in all respect ) 585 rcc work of building with internal wiring works for extension of control room building ( 36 sqmm ) ( complete works in all respect ) as per approved drawing and specification 586 water pump, toilet works as per approved drawing and specification...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32081339 development of distribution infrastructure at banda zone ( electricity distribution circles edc banda, edc chitrakoot, edc hamirpur and edc mahoba ) , district banda, chitrakoot, hamirpur & mahoba of uttar pradeshstate under the revamped reforms based and results linked, distribution sector scheme 1 supply of items 2 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 3 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 4 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 5 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 6 stone pad ( 300x300x75mm ) 7 1 core ( al. ) 120mm2 lt armoured xlpe cable 8 1 core ( al. ) 95mm2 lt armoured xlpe cable 9 1 core ( al. ) 50mm2 lt armoured xlpe cable 10 1 core ( al. ) 25mm2 lt armoured xlpe cable 11 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 12 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 13 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 14 armoured service cable 2cx4 sqmm for single phase consumer 15 armoured service cable 2cx6 sqmm for single phase consumer 16 armoured service cable 4cx10 sqmm for three phase consumer 17 armoured service cable 4cx16 sqmm for three phase consumer 18 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 19 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 20 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 21 lt pvc cable 3.5x150 sq mm 22 lt pvc cable 3.5x70 sq mm 23 lt pvc cable 4x16 sq mm 24 l.t. pvc cable 10 sq. mm single core 25 lt pvc cable 3.5x400 sq mm 26 acsr rabbit conductor 27 aluminium binding wire 6 swg 28 jointing sleave 29 mid span joint 120mm2 30 acsr rabbit conductor jumpering works 31 acsr weasel conductor jumpering works 32 11 kv danger board with clamp and nuts & bolts 33 11 kv number plate with clamp and nuts & bolts 34 11kv fuse set ( drop out ) with clamps 35 11kv tpmo with fixing clamps 36 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 37 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 38 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 39 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 40 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 41 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 42 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 43 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 44 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 45 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 46 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 47 4 core lt mcb with box 48 copper l piece 50x225x10mm 49 copper l piece 50x225x12mm 50 al leg long barrel off size 51 9 kv la , 5 ka ( distribution class ) 52 9 kv la , 10 ka ( station class ) 53 earthing coil connected with nutbolt using charchol and salt 54 gi flat 50x6 for earthing 55 gi flat 25x3 for earthing 56 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 57 gi pipe 6 diameter with clamps 58 g.i. barbed wire 59 g.i. wire no. 16 swg for binding 60 g.i. wire 6 swg 61 g.i. wire 8 swg 62 33 kv g.i. pin ( 10 kn ) with nuts & washers 63 11 kv disc fitting b & s type ( 45 kn ) 64 11 kv disc. insulators b&s type 45 kn ( polymer type ) 65 11 kv pin insulator polymer type as per ts 66 33 kv pin insulator 67 lt shackle insulator 68 insulating piercing connector ( 50 150 sq.mm ) 69 insulating piercing connector ( 16 150 sq.mm ) 70 dead end clamp ( insulated ) 71 end cap for ab cable 72 suspension clamps ( insulated ) 73 pole clamps with with i hook & nut & bolts for laying abc 74 d straps 75 insulation mastic tape ( 2inc x 10 feet ) . 76 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 77 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 78 aluminium paint 79 red oxide paint 80 smart tvm meter compatible with system ( ami ) complete set 81 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 82 crimping type heavy duty aluminium lugs suitable for connection pvc cables 83 armour rod with ferrules for acsr rabbit / weasel helical performed 84 cable route marker 85 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 86 pg clamp for rabbit 87 gi stay wire 7 / 10 swg 88 gi stay wire 7 / 8 swg 89 ht guy insulator 90 lt guy insulator 91 33 kv stay complete ( gi stay rod 20x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 92 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 93 turn buckle 94 ht stay clamp as per approved drawing 33 kv 95 ht stay clamp as per approved drawing 11 kv 96 lt stay clamp as per approved drawing 97 11 kv cross arm holding clamps with bolts & nuts 98 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 99 33 kv cross arm holding clamps with bolts & nuts 100 33 kv steel x arm v type ( gi channel 100 x 50 x 6 mm ) 101 angle for vertical arml50x50x6 ( type a ) 900mm 102 angle for vertical arml50x50x6 ( type b ) 900mm 103 top clamp for vertical arm l 50x6 ( type a ) 435 mm 104 top clamp for vertical arm l 50x6 ( type b ) 435 mm 105 bottom clamp for vertical arm l 50x6 ( type a ) 507 mm 106 bottom clamp for vertical arm l 50x6 ( type b ) 507 mm 107 clamp for top channel with nut bolt 108 clamps for lt t off with bolts & nuts 109 e bracket for 11 kv line 110 eye bolt 111 f bracket for 11 kv line 112 f bracket for 33 kv line 113 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 114 holding clamps for top channel, gi channel & gi angle with bolts & nuts 115 m.s. top channel 100x50x6 mm., 2240 mmlong 116 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 117 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 118 m.s. top channel 125x65x6 mm., 2240 mmlong 119 tee off channel 100x50x1300 mm with clamp, nut & bolt 120 clamps for dist. box ( 40x6 mm ) 121 clamps for t / f ( 75x8 mm gi flat ) . 122 gi. guarding angle 75x75x6 mm 3010 mm long with clamp 123 height raising channel 100x50, 2240 mm long 124 back clamp for height raising channel holding clamps with bolts & nuts 125 gi channel 100x50x6 mm. 1300 mm long 126 gi channel clamp with nuts & bolts 127 gi angle iron 50x50x6 mm bracing with 4 clamps 128 gi channel 125x65 mm 129 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 130 gi channel 75x75x6 mm &bolt and nut ( t / f base support ) 131 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 132 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 133 cable jointing kit straight through ( 3x185 ) 134 extra prefabricated items like clamp , channel, angle with nut bolt 135 erection part 136 conversion of existing service cable to new armoured service cable with all required accessories like j pipe , shaddle , conduit pipe , clamp , gi wire , reel insulator , earthing bolt and lugs etc. ( complete work in all respect ) and removing and shifting of existing material to client store 137 armoured service cable 2cx4 sqmm for single phase consumer 138 armoured service cable 2cx6 sqmm for single phase consumer 139 armoured service cable 4cx10 sqmm for three phase consumer 140 armoured service cable 4cx16 sqmm for three phase consumer 141 erection, testingand commissioning of replacement oflt bare conductor with ab cables ( complete work in all respect ) 142 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 143 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 144 stone pad ( 300x300x75mm ) 145 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 146 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 147 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 148 pole clamps with with i hook & nut & bolts for laying abc 149 dead end clamp ( insulated ) 150 suspension clamps ( insulated ) 151 insulating piercing connector ( 16 150 sq.mm ) 152 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 153 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 154 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 155 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 156 earthing coil connected with nutbolt using charchol and salt 157 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 158 lt guy insulator 159 gi stay wire 7 / 10 swg 160 lt stay clamp as per approved drawing 161 removing and shifting of existing material to client store 162 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 163 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 164 erection, testingand commissioning of replacement ofab cable ( damage ) with ab cables ( complete work in all respect ) 165 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 166 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 167 stone pad ( 300x300x75mm ) 168 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 169 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 170 pole clamps with with i hook & nut & bolts for laying abc 171 dead end clamp ( insulated ) 172 suspension clamps ( insulated ) 173 insulating piercing connector ( 16 150 sq.mm ) 174 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 175 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 176 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 177 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 178 earthing coil connected with nutbolt using charchol and salt 179 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 180 lt guy insulator 181 gi stay wire 7 / 10 swg 182 lt stay clamp as per approved drawing 183 removing and shifting of existing material to client store 184 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 185 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 186 erection, testingand commissioning of replacement of lt line with xlpe armoured cables ( complete work in all respect ) 187 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 188 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 189 stone pad ( 300x300x75mm ) 190 angle for vertical arml50x50x6 ( type a ) 900mm 191 top clamp for vertical arm l 50x6 ( type a ) 435 mm 192 bottom clamp for vertical arm l 50x6 ( type a ) 507 mm 193 angle for vertical arml50x50x6 ( type b ) 900mm 194 top clamp for vertical arm l 50x6 ( type b ) 435 mm 195 bottom clamp for vertical arm l 50x6 ( type b ) 507 mm 196 lt shackle insulator 197 d straps 198 1 core ( al. ) 120mm2 lt armoured xlpe cable 199 1 core ( al. ) 95mm2 lt armoured xlpe cable 200 1 core ( al. ) 50mm2 lt armoured xlpe cable 201 1 core ( al. ) 25mm2 lt armoured xlpe cable 202 mid span joint 120mm2 203 insulating piercing connector ( 50 150 sq.mm ) 204 insulation mastic tape ( 2inc x 10 feet ) . 205 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 206 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 207 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 208 earthing coil connected with nutbolt using charchol and salt 209 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 210 lt guy insulator 211 gi stay wire 7 / 10 swg 212 lt stay clamp as per approved drawing 213 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 214 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 215 removing and shifting of existing material to client store 216 survey , erection, testingand commissioning of 11 kv line ( feeder spliting due to over loading ) on 8.5 mtr pcc pole 115.6 ckm and 11 mtr stp pole 151.4 ckm ( complete work in all respect ) 217 route survey and pole spotting for 11 kv line 218 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 219 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 220 acsr rabbit conductor 221 stone pad ( 300x300x75mm ) 222 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 223 11 kv cross arm holding clamps with bolts & nuts 224 f bracket for 11 kv line 225 m.s. top channel 100x50x6 mm., 2240 mmlong 226 clamp for top channel with nut bolt 227 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 228 e bracket for 11 kv line 229 11 kv pin insulator polymer type as per ts 230 11 kv disc. insulators b&s type 45 kn ( polymer type ) 231 11 kv disc fitting b & s type ( 45 kn ) 232 pg clamp for rabbit 233 aluminium binding wire 6 swg 234 jointing sleave 235 11 kv danger board with clamp and nuts & bolts 236 g.i. barbed wire 237 aluminium paint 238 red oxide paint 239 earthing coil connected with nutbolt using charchol and salt 240 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 241 ht guy insulator 242 gi stay wire 7 / 10 swg 243 ht stay clamp as per approved drawing 11 kv 244 11 kv number plate with clamp and nuts & bolts 245 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 246 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 247 erection, testingand commissioning of 11 kv vcb with complete assoceries as apporoved drawing and tecchanical specifiactions ( complete work in all respect ) 248 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 249 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 250 smart tvm meter compatible with system ( ami ) complete set 251 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 252 gi flat 50x6 for earthing 253 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 254 stone pad ( 300x300x75mm ) 255 m.s. top channel 100x50x6 mm., 2240 mmlong 256 clamp for top channel with nut bolt 257 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 258 11 kv disc. insulators b&s type 45 kn ( polymer type ) 259 11 kv disc fitting b & s type ( 45 kn ) 260 pg clamp for rabbit 261 11 kv danger board with clamp and nuts & bolts 262 g.i. barbed wire 263 earthing coil connected with nutbolt using charchol and salt 264 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 265 ht guy insulator 266 gi stay wire 7 / 10 swg 267 ht stay clamp as per approved drawing 11 kv 268 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 269 survey , erection, testingand commissioning of 11 kv line ( feeder sagrigation ) ( complete work in all respect ) 270 route survey and pole spotting for 11 kv line 271 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 272 acsr rabbit conductor 273 stone pad ( 300x300x75mm ) 274 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 275 11 kv cross arm holding clamps with bolts & nuts 276 f bracket for 11 kv line 277 m.s. top channel 100x50x6 mm., 2240 mmlong 278 clamp for top channel with nut bolt 279 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 280 e bracket for 11 kv line 281 11 kv pin insulator polymer type as per ts 282 11 kv disc. insulators b&s type 45 kn ( polymer type ) 283 11 kv disc fitting b & s type ( 45 kn ) 284 pg clamp for rabbit 285 aluminium binding wire 6 swg 286 jointing sleave 287 11 kv danger board with clamp and nuts & bolts 288 g.i. barbed wire 289 earthing coil connected with nutbolt using charchol and salt 290 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 291 ht guy insulator 292 gi stay wire 7 / 10 swg 293 ht stay clamp as per approved drawing 11 kv 294 11 kv number plate with clamp and nuts & bolts 295 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 296 erection, testingand commissioning of 11 kv vcb with complete assoceries as apporoved drawing and tecchanical specifiactions ( feeder segrigation ) ( complete work in all respect ) 297 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 298 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 299 smart tvm meter compatible with system ( ami ) complete set 300 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 301 gi flat 50x6 for earthing 302 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 303 stone pad ( 300x300x75mm ) 304 m.s. top channel 100x50x6 mm., 2240 mmlong 305 clamp for top channel with nut bolt 306 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 307 11 kv disc. insulators b&s type 45 kn ( polymer type ) 308 11 kv disc fitting b & s type ( 45 kn ) 309 pg clamp for rabbit 310 11 kv danger board with clamp and nuts & bolts 311 g.i. barbed wire 312 earthing coil connected with nutbolt using charchol and salt 313 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 314 ht guy insulator 315 gi stay wire 7 / 10 swg 316 ht stay clamp as per approved drawing 11 kv 317 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 318 erection, testingand commissioning of 11 kv nh crossing ( complete work in all respect ) 319 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 320 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 321 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 322 gi pipe 6 diameter with clamps 323 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 324 gi angle iron 50x50x6 mm bracing with 4 clamps 325 m.s. top channel 100x50x6 mm., 2240 mmlong 326 clamp for top channel with nut bolt 327 g.i. barbed wire 328 stone pad ( 300x300x75mm ) 329 11 kv pin insulator polymer type as per ts 330 11 kv disc. insulators b&s type 45 kn ( polymer type ) 331 11 kv disc fitting b & s type ( 45 kn ) 332 pg clamp for rabbit 333 e bracket for 11 kv line 334 11 kv danger board with clamp and nuts & bolts 335 aluminium paint 336 red oxide paint 337 earthing coil connected with nutbolt using charchol and salt 338 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 339 ht guy insulator 340 gi stay wire 7 / 10 swg 341 ht stay clamp as per approved drawing 11 kv 342 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 343 cable laying including cost of material eg. , bricks, sand, clamps etc. 344 erection, testingand commissioning of 11 kv railway crossing ( complete work in all respect ) 345 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 346 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 347 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 348 gi pipe 6 diameter with clamps 349 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 350 gi angle iron 50x50x6 mm bracing with 4 clamps 351 m.s. top channel 100x50x6 mm., 2240 mmlong 352 clamp for top channel with nut bolt 353 g.i. barbed wire 354 stone pad ( 300x300x75mm ) 355 11 kv pin insulator polymer type as per ts 356 11 kv disc. insulators b&s type 45 kn ( polymer type ) 357 11 kv disc fitting b & s type ( 45 kn ) 358 pg clamp for rabbit 359 e bracket for 11 kv line 360 11 kv danger board with clamp and nuts & bolts 361 aluminium paint 362 red oxide paint 363 earthing coil connected with nutbolt using charchol and salt 364 9 kv la , 10 ka ( station class ) 365 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 366 ht guy insulator 367 gi stay wire 7 / 10 swg 368 ht stay clamp as per approved drawing 11 kv 369 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 370 cable laying including cost of material eg. , bricks, sand, clamps etc. 371 erection, testingand commissioning of 11 kv line crossing by 33kv lines on stp 13 mtr with cradle guarding ( complete work in all respect ) 372 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 373 33 kv steel x arm v type ( gi channel 100 x 50 x 6 mm ) 374 33 kv cross arm holding clamps with bolts & nuts 375 33 kv pin insulator 376 33 kv g.i. pin ( 10 kn ) with nuts & washers 377 gi. guarding angle 75x75x6 mm 3010 mm long with clamp 378 f bracket for 33 kv line 379 turn buckle 380 g.i. wire 6 swg 381 g.i. wire 8 swg 382 g.i. wire no. 16 swg for binding 383 eye bolt 384 armour rod with ferrules for acsr rabbit / weasel helical performed 385 stone pad ( 300x300x75mm ) 386 11 kv danger board with clamp and nuts & bolts 387 11 kv number plate with clamp and nuts & bolts 388 g.i. barbed wire 389 red oxide paint 390 aluminium paint 391 aluminium binding wire 6 swg 392 earthing coil connected with nutbolt using charchol and salt 393 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 394 33 kv stay complete ( gi stay rod 20x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 395 ht guy insulator 396 gi stay wire 7 / 8 swg 397 ht stay clamp as per approved drawing 33 kv 398 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.64 cmt ( 13 meter stp ) as per approved drawing 399 erection, testingand commissioning of lt line crossing by 11 kv lines on stp 11 mtr with cradle guarding ( complete work in all respect ) 400 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 401 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 402 11 kv cross arm holding clamps with bolts & nuts 403 11 kv pin insulator polymer type as per ts 404 f bracket for 11 kv line 405 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 406 turn buckle 407 g.i. wire 6 swg 408 g.i. wire 8 swg 409 g.i. wire no. 16 swg for binding 410 eye bolt 411 armour rod with ferrules for acsr rabbit / weasel helical performed 412 stone pad ( 300x300x75mm ) 413 11 kv danger board with clamp and nuts & bolts 414 11 kv number plate with clamp and nuts & bolts 415 g.i. barbed wire 416 red oxide paint 417 aluminium paint 418 aluminium binding wire 6 swg 419 earthing coil connected with nutbolt using charchol and salt 420 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 421 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 422 ht guy insulator 423 gi stay wire 7 / 8 swg 424 ht stay clamp as per approved drawing 11 kv 425 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 426 erection, testingand commissioning of ug cable 11 kv line ( complete work in all respect ) 427 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 428 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 429 cable jointing kit straight through ( 3x185 ) 430 gi pipe 6 diameter with clamps 431 cable route marker 432 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 433 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 434 gi angle iron 50x50x6 mm bracing with 4 clamps 435 m.s. top channel 100x50x6 mm., 2240 mmlong 436 clamp for top channel with nut bolt 437 g.i. barbed wire 438 stone pad ( 300x300x75mm ) 439 11 kv pin insulator polymer type as per ts 440 11 kv disc. insulators b&s type 45 kn ( polymer type ) 441 11 kv disc fitting b & s type ( 45 kn ) 442 pg clamp for rabbit 443 e bracket for 11 kv line 444 11 kv danger board with clamp and nuts & bolts 445 aluminium paint 446 red oxide paint 447 earthing coil connected with nutbolt using charchol and salt 448 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 449 ht guy insulator 450 gi stay wire 7 / 10 swg 451 ht stay clamp as per approved drawing 11 kv 452 road restoration chages forroad crossing 453 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 454 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 25 kva , 63 kva and 100 kva ( complete work in all respect ) 455 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 456 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 457 stone pad ( 300x300x75mm ) 458 clamps for lt t off with bolts & nuts 459 holding clamps for top channel, gi channel & gi angle with bolts & nuts 460 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 461 m.s. top channel 125x65x6 mm., 2240 mmlong 462 11 kv disc. insulators b&s type 45 kn ( polymer type ) 463 11 kv disc fitting b & s type ( 45 kn ) 464 tee off channel 100x50x1300 mm with clamp, nut & bolt 465 11 kv pin insulator polymer type as per ts 466 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 467 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 468 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 469 11kv tpmo with fixing clamps 470 11kv fuse set ( drop out ) with clamps 471 9 kv la , 5 ka ( distribution class ) 472 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 473 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 474 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 475 lt pvc cable 4x16 sq mm 476 lt pvc cable 3.5x70 sq mm 477 lt pvc cable 3.5x150 sq mm 478 11 kv danger board with clamp and nuts & bolts 479 g.i. barbed wire 480 acsr rabbit conductor jumpering works 481 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 482 ht guy insulator 483 gi stay wire 7 / 10 swg 484 ht stay clamp as per approved drawing 11 kv 485 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 486 gi flat 25x3 for earthing 487 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 488 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 10 kva and 16 kva ( complete work in all respect ) 489 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 490 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 491 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 492 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 493 clamps for dist. box ( 40x6 mm ) 494 clamps for t / f ( 75x8 mm gi flat ) . 495 acsr weasel conductor jumpering works 496 11 kv pin insulator polymer type as per ts 497 eye bolt 498 l.t. pvc cable 10 sq. mm single core 499 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 500 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 501 ht guy insulator 502 gi stay wire 7 / 10 swg 503 ht stay clamp as per approved drawing 11 kv 504 relocation , testing and commissioningof 250 kva , 11 / 0.433 kv three phase transformer sub station ( complete work in all respect ) 505 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 506 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 507 stone pad ( 300x300x75mm ) 508 holding clamps for top channel, gi channel & gi angle with bolts & nuts 509 m.s. top channel 125x65x6 mm., 2240 mmlong 510 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 511 gi channel 75x75x6 mm &bolt and nut ( t / f base support ) 512 11 kv disc. insulators b&s type 45 kn ( polymer type ) 513 11 kv disc fitting b & s type ( 45 kn ) 514 tee off channel 100x50x1300 mm with clamp, nut & bolt 515 clamps for lt t off with bolts & nuts 516 11 kv pin insulator polymer type as per ts 517 11kv tpmo with fixing clamps 518 11kv fuse set ( drop out ) with clamps 519 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 520 copper l piece 50x225x10mm 521 copper l piece 50x225x12mm 522 lt pvc cable 3.5x400 sq mm 523 al leg long barrel off size 524 4 core lt mcb with box 525 11 kv danger board with clamp and nuts & bolts 526 g.i. barbed wire 527 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 528 ht guy insulator 529 gi stay wire 7 / 10 swg 530 ht stay clamp as per approved drawing 11 kv 531 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 532 gi flat 50x6 for earthing 533 gi channel 125x65 mm 534 9 kv la , 5 ka ( distribution class ) 535 crimping type heavy duty aluminium lugs suitable for connection pvc cables 536 pg clamp for rabbit 537 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 538 dts plinth foundation 539 dismentaling of distribution transformer along with accessories. relocate the dt only at new location , testing , comissioning and charging and other shifting to store. 540 erection, testingand commissioning of new lt line with ab cable ( complete work in all respect ) 541 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 542 stone pad ( 300x300x75mm ) 543 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 544 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 545 pole clamps with with i hook & nut & bolts for laying abc 546 dead end clamp ( insulated ) 547 suspension clamps ( insulated ) 548 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 549 insulating piercing connector ( 16 150 sq.mm ) 550 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 551 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 552 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 553 earthing coil connected with nutbolt using charchol and salt 554 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 555 lt guy insulator 556 gi stay wire 7 / 10 swg 557 lt stay clamp as per approved drawing 558 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 559 erection, testingand commissioning of 11kv line guarding ( complete work in all respect ) 560 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 561 height raising channel 100x50, 2240 mm long 562 back clamp for height raising channel holding clamps with bolts & nuts 563 g.i. wire 6 swg 564 g.i. wire 8 swg 565 turn buckle 566 eye bolt 567 g.i. wire no. 16 swg for binding 568 earthing coil connected with nutbolt using charchol and salt 569 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 570 ht guy insulator 571 gi stay wire 7 / 10 swg 572 ht stay clamp as per approved drawing 11 kv 573 erection, testingand commissioning of tee of channel ( complete work in all respect ) 574 gi channel 100x50x6 mm. 1300 mm long 575 gi channel clamp with nuts & bolts 576 11 kv disc. insulators b&s type 45 kn ( polymer type ) 577 11 kv disc fitting b & s type ( 45 kn ) 578 11 kv pin insulator polymer type as per ts 579 pg clamp for rabbit 580 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 581 ht guy insulator 582 gi stay wire 7 / 10 swg 583 ht stay clamp as per approved drawing 11 kv 584 control room building extention work ( complete work in all respect ) 585 rcc work of building with internal wiring works for extension of control room building ( 36 sqmm ) ( complete works in all respect ) as per approved drawing and specification 586 water pump, toilet works as per approved drawing and specification...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32081321 development of distribution infrastructure at jhansi zone ( electricity distribution circles jhansi urban, jhansi rural, lalitpur and orai ( jalaun ) [ district jhansi, lalitpur and jalaun ] of uttar pradeshstate under the revamped reforms based and results linked, distribution sector scheme 1 supply of items 2 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 3 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 4 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 5 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 6 stone pad ( 300x300x75mm ) 7 1 core ( al. ) 120mm2 lt armoured xlpe cable 8 1 core ( al. ) 95mm2 lt armoured xlpe cable 9 1 core ( al. ) 50mm2 lt armoured xlpe cable 10 1 core ( al. ) 25mm2 lt armoured xlpe cable 11 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 12 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 13 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 14 armoured service cable 2cx4 sqmm for single phase consumer 15 armoured service cable 2cx6 sqmm for single phase consumer 16 armoured service cable 4cx10 sqmm for three phase consumer 17 armoured service cable 4cx16 sqmm for three phase consumer 18 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 19 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 20 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 21 lt pvc cable 3.5x150 sq mm 22 lt pvc cable 3.5x70 sq mm 23 lt pvc cable 4x16 sq mm 24 l.t. pvc cable 10 sq. mm single core 25 lt pvc cable 3.5x400 sq mm 26 acsr rabbit conductor 27 aluminium binding wire 6 swg 28 jointing sleave 29 mid span joint 120mm2 30 acsr rabbit conductor jumpering works 31 acsr weasel conductor jumpering works 32 11 kv danger board with clamp and nuts & bolts 33 11 kv number plate with clamp and nuts & bolts 34 11kv fuse set ( drop out ) with clamps 35 11kv tpmo with fixing clamps 36 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 37 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 38 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 39 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 40 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 41 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 42 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 43 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 44 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 45 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 46 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 47 4 core lt mcb with box 48 copper l piece 50x225x10mm 49 copper l piece 50x225x12mm 50 al leg long barrel off size 51 9 kv la , 5 ka ( distribution class ) 52 9 kv la , 10 ka ( station class ) 53 earthing coil connected with nutbolt using charchol and salt 54 gi flat 50x6 for earthing 55 gi flat 25x3 for earthing 56 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 57 gi pipe 6 diameter with clamps 58 g.i. barbed wire 59 g.i. wire no. 16 swg for binding 60 g.i. wire 6 swg 61 g.i. wire 8 swg 62 33 kv g.i. pin ( 10 kn ) with nuts & washers 63 11 kv disc fitting b & s type ( 45 kn ) 64 11 kv disc. insulators b&s type 45 kn ( polymer type ) 65 11 kv pin insulator polymer type as per ts 66 33 kv pin insulator 67 lt shackle insulator 68 insulating piercing connector ( 50 150 sq.mm ) 69 insulating piercing connector ( 16 150 sq.mm ) 70 dead end clamp ( insulated ) 71 end cap for ab cable 72 suspension clamps ( insulated ) 73 pole clamps with with i hook & nut & bolts for laying abc 74 d straps 75 insulation mastic tape ( 2inc x 10 feet ) . 76 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 77 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 78 aluminium paint 79 red oxide paint 80 smart tvm meter compatible with system ( ami ) complete set 81 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 82 crimping type heavy duty aluminium lugs suitable for connection pvc cables 83 armour rod with ferrules for acsr rabbit / weasel helical performed 84 cable route marker 85 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 86 pg clamp for rabbit 87 gi stay wire 7 / 10 swg 88 gi stay wire 7 / 8 swg 89 ht guy insulator 90 lt guy insulator 91 33 kv stay complete ( gi stay rod 20x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 92 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 93 turn buckle 94 ht stay clamp as per approved drawing 33 kv 95 ht stay clamp as per approved drawing 11 kv 96 lt stay clamp as per approved drawing 97 11 kv cross arm holding clamps with bolts & nuts 98 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 99 33 kv cross arm holding clamps with bolts & nuts 100 33 kv steel x arm v type ( gi channel 100 x 50 x 6 mm ) 101 angle for vertical arml50x50x6 ( type a ) 900mm 102 angle for vertical arml50x50x6 ( type b ) 900mm 103 top clamp for vertical arm l 50x6 ( type a ) 435 mm 104 top clamp for vertical arm l 50x6 ( type b ) 435 mm 105 bottom clamp for vertical arm l 50x6 ( type a ) 507 mm 106 bottom clamp for vertical arm l 50x6 ( type b ) 507 mm 107 clamp for top channel with nut bolt 108 clamps for lt t off with bolts & nuts 109 e bracket for 11 kv line 110 eye bolt 111 f bracket for 11 kv line 112 f bracket for 33 kv line 113 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 114 holding clamps for top channel, gi channel & gi angle with bolts & nuts 115 m.s. top channel 100x50x6 mm., 2240 mmlong 116 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 117 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 118 m.s. top channel 125x65x6 mm., 2240 mmlong 119 tee off channel 100x50x1300 mm with clamp, nut & bolt 120 clamps for dist. box ( 40x6 mm ) 121 clamps for t / f ( 75x8 mm gi flat ) . 122 gi. guarding angle 75x75x6 mm 3010 mm long with clamp 123 height raising channel 100x50, 2240 mm long 124 back clamp for height raising channel holding clamps with bolts & nuts 125 gi channel 100x50x6 mm. 1300 mm long 126 gi channel clamp with nuts & bolts 127 gi angle iron 50x50x6 mm bracing with 4 clamps 128 gi channel 125x65 mm 129 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 130 gi channel 75x75x6 mm &bolt and nut ( t / f base support ) 131 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 132 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 133 cable jointing kit straight through ( 3x185 ) 134 extra prefabricated items like clamp , channel, angle with nut bolt 135 erection part 136 conversion of existing service cable to new armoured service cable with all required accessories like j pipe , shaddle , conduit pipe , clamp , gi wire , reel insulator , earthing bolt and lugs etc. ( complete work in all respect ) and removing and shifting of existing material to client store 137 armoured service cable 2cx4 sqmm for single phase consumer 138 armoured service cable 2cx6 sqmm for single phase consumer 139 armoured service cable 4cx10 sqmm for three phase consumer 140 armoured service cable 4cx16 sqmm for three phase consumer 141 erection, testingand commissioning of replacement oflt bare conductor with ab cables ( complete work in all respect ) 142 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 143 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 144 stone pad ( 300x300x75mm ) 145 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 146 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 147 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 148 pole clamps with with i hook & nut & bolts for laying abc 149 dead end clamp ( insulated ) 150 suspension clamps ( insulated ) 151 insulating piercing connector ( 16 150 sq.mm ) 152 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 153 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 154 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 155 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 156 earthing coil connected with nutbolt using charchol and salt 157 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 158 lt guy insulator 159 gi stay wire 7 / 10 swg 160 lt stay clamp as per approved drawing 161 removing and shifting of existing material to client store 162 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 163 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 164 erection, testingand commissioning of replacement ofab cable ( damage ) with ab cables ( complete work in all respect ) 165 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 166 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 167 stone pad ( 300x300x75mm ) 168 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 169 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 170 pole clamps with with i hook & nut & bolts for laying abc 171 dead end clamp ( insulated ) 172 suspension clamps ( insulated ) 173 insulating piercing connector ( 16 150 sq.mm ) 174 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 175 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 176 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 177 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 178 earthing coil connected with nutbolt using charchol and salt 179 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 180 lt guy insulator 181 gi stay wire 7 / 10 swg 182 lt stay clamp as per approved drawing 183 removing and shifting of existing material to client store 184 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 185 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 186 erection, testingand commissioning of replacement of lt line with xlpe armoured cables ( complete work in all respect ) 187 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 188 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 189 stone pad ( 300x300x75mm ) 190 angle for vertical arml50x50x6 ( type a ) 900mm 191 top clamp for vertical arm l 50x6 ( type a ) 435 mm 192 bottom clamp for vertical arm l 50x6 ( type a ) 507 mm 193 angle for vertical arml50x50x6 ( type b ) 900mm 194 top clamp for vertical arm l 50x6 ( type b ) 435 mm 195 bottom clamp for vertical arm l 50x6 ( type b ) 507 mm 196 lt shackle insulator 197 d straps 198 1 core ( al. ) 120mm2 lt armoured xlpe cable 199 1 core ( al. ) 95mm2 lt armoured xlpe cable 200 1 core ( al. ) 50mm2 lt armoured xlpe cable 201 1 core ( al. ) 25mm2 lt armoured xlpe cable 202 mid span joint 120mm2 203 insulating piercing connector ( 50 150 sq.mm ) 204 insulation mastic tape ( 2inc x 10 feet ) . 205 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 206 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 207 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 208 earthing coil connected with nutbolt using charchol and salt 209 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 210 lt guy insulator 211 gi stay wire 7 / 10 swg 212 lt stay clamp as per approved drawing 213 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 214 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 215 removing and shifting of existing material to client store 216 survey , erection, testingand commissioning of 11 kv line ( feeder spliting due to over loading ) on 8.5 mtr pcc pole 115.6 ckm and 11 mtr stp pole 151.4 ckm ( complete work in all respect ) 217 route survey and pole spotting for 11 kv line 218 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 219 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 220 acsr rabbit conductor 221 stone pad ( 300x300x75mm ) 222 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 223 11 kv cross arm holding clamps with bolts & nuts 224 f bracket for 11 kv line 225 m.s. top channel 100x50x6 mm., 2240 mmlong 226 clamp for top channel with nut bolt 227 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 228 e bracket for 11 kv line 229 11 kv pin insulator polymer type as per ts 230 11 kv disc. insulators b&s type 45 kn ( polymer type ) 231 11 kv disc fitting b & s type ( 45 kn ) 232 pg clamp for rabbit 233 aluminium binding wire 6 swg 234 jointing sleave 235 11 kv danger board with clamp and nuts & bolts 236 g.i. barbed wire 237 aluminium paint 238 red oxide paint 239 earthing coil connected with nutbolt using charchol and salt 240 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 241 ht guy insulator 242 gi stay wire 7 / 10 swg 243 ht stay clamp as per approved drawing 11 kv 244 11 kv number plate with clamp and nuts & bolts 245 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 246 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 247 erection, testingand commissioning of 11 kv vcb with complete assoceries as apporoved drawing and tecchanical specifiactions ( complete work in all respect ) 248 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 249 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 250 smart tvm meter compatible with system ( ami ) complete set 251 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 252 gi flat 50x6 for earthing 253 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 254 stone pad ( 300x300x75mm ) 255 m.s. top channel 100x50x6 mm., 2240 mmlong 256 clamp for top channel with nut bolt 257 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 258 11 kv disc. insulators b&s type 45 kn ( polymer type ) 259 11 kv disc fitting b & s type ( 45 kn ) 260 pg clamp for rabbit 261 11 kv danger board with clamp and nuts & bolts 262 g.i. barbed wire 263 earthing coil connected with nutbolt using charchol and salt 264 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 265 ht guy insulator 266 gi stay wire 7 / 10 swg 267 ht stay clamp as per approved drawing 11 kv 268 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 269 survey , erection, testingand commissioning of 11 kv line ( feeder sagrigation ) ( complete work in all respect ) 270 route survey and pole spotting for 11 kv line 271 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 272 acsr rabbit conductor 273 stone pad ( 300x300x75mm ) 274 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 275 11 kv cross arm holding clamps with bolts & nuts 276 f bracket for 11 kv line 277 m.s. top channel 100x50x6 mm., 2240 mmlong 278 clamp for top channel with nut bolt 279 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 280 e bracket for 11 kv line 281 11 kv pin insulator polymer type as per ts 282 11 kv disc. insulators b&s type 45 kn ( polymer type ) 283 11 kv disc fitting b & s type ( 45 kn ) 284 pg clamp for rabbit 285 aluminium binding wire 6 swg 286 jointing sleave 287 11 kv danger board with clamp and nuts & bolts 288 g.i. barbed wire 289 earthing coil connected with nutbolt using charchol and salt 290 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 291 ht guy insulator 292 gi stay wire 7 / 10 swg 293 ht stay clamp as per approved drawing 11 kv 294 11 kv number plate with clamp and nuts & bolts 295 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 296 erection, testingand commissioning of 11 kv vcb with complete assoceries as apporoved drawing and tecchanical specifiactions ( feeder segrigation ) ( complete work in all respect ) 297 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 298 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 299 smart tvm meter compatible with system ( ami ) complete set 300 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 301 gi flat 50x6 for earthing 302 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 303 stone pad ( 300x300x75mm ) 304 m.s. top channel 100x50x6 mm., 2240 mmlong 305 clamp for top channel with nut bolt 306 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 307 11 kv disc. insulators b&s type 45 kn ( polymer type ) 308 11 kv disc fitting b & s type ( 45 kn ) 309 pg clamp for rabbit 310 11 kv danger board with clamp and nuts & bolts 311 g.i. barbed wire 312 earthing coil connected with nutbolt using charchol and salt 313 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 314 ht guy insulator 315 gi stay wire 7 / 10 swg 316 ht stay clamp as per approved drawing 11 kv 317 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 318 erection, testingand commissioning of 11 kv nh crossing ( complete work in all respect ) 319 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 320 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 321 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 322 gi pipe 6 diameter with clamps 323 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 324 gi angle iron 50x50x6 mm bracing with 4 clamps 325 m.s. top channel 100x50x6 mm., 2240 mmlong 326 clamp for top channel with nut bolt 327 g.i. barbed wire 328 stone pad ( 300x300x75mm ) 329 11 kv pin insulator polymer type as per ts 330 11 kv disc. insulators b&s type 45 kn ( polymer type ) 331 11 kv disc fitting b & s type ( 45 kn ) 332 pg clamp for rabbit 333 e bracket for 11 kv line 334 11 kv danger board with clamp and nuts & bolts 335 aluminium paint 336 red oxide paint 337 earthing coil connected with nutbolt using charchol and salt 338 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 339 ht guy insulator 340 gi stay wire 7 / 10 swg 341 ht stay clamp as per approved drawing 11 kv 342 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 343 cable laying including cost of material eg. , bricks, sand, clamps etc. 344 erection, testingand commissioning of 11 kv railway crossing ( complete work in all respect ) 345 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 346 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 347 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 348 gi pipe 6 diameter with clamps 349 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 350 gi angle iron 50x50x6 mm bracing with 4 clamps 351 m.s. top channel 100x50x6 mm., 2240 mmlong 352 clamp for top channel with nut bolt 353 g.i. barbed wire 354 stone pad ( 300x300x75mm ) 355 11 kv pin insulator polymer type as per ts 356 11 kv disc. insulators b&s type 45 kn ( polymer type ) 357 11 kv disc fitting b & s type ( 45 kn ) 358 pg clamp for rabbit 359 e bracket for 11 kv line 360 11 kv danger board with clamp and nuts & bolts 361 aluminium paint 362 red oxide paint 363 earthing coil connected with nutbolt using charchol and salt 364 9 kv la , 10 ka ( station class ) 365 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 366 ht guy insulator 367 gi stay wire 7 / 10 swg 368 ht stay clamp as per approved drawing 11 kv 369 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 370 cable laying including cost of material eg. , bricks, sand, clamps etc. 371 erection, testingand commissioning of 11 kv line crossing by 33kv lines on stp 13 mtr with cradle guarding ( complete work in all respect ) 372 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 373 33 kv steel x arm v type ( gi channel 100 x 50 x 6 mm ) 374 33 kv cross arm holding clamps with bolts & nuts 375 33 kv pin insulator 376 33 kv g.i. pin ( 10 kn ) with nuts & washers 377 gi. guarding angle 75x75x6 mm 3010 mm long with clamp 378 f bracket for 33 kv line 379 turn buckle 380 g.i. wire 6 swg 381 g.i. wire 8 swg 382 g.i. wire no. 16 swg for binding 383 eye bolt 384 armour rod with ferrules for acsr rabbit / weasel helical performed 385 stone pad ( 300x300x75mm ) 386 11 kv danger board with clamp and nuts & bolts 387 11 kv number plate with clamp and nuts & bolts 388 g.i. barbed wire 389 red oxide paint 390 aluminium paint 391 aluminium binding wire 6 swg 392 earthing coil connected with nutbolt using charchol and salt 393 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 394 33 kv stay complete ( gi stay rod 20x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 395 ht guy insulator 396 gi stay wire 7 / 8 swg 397 ht stay clamp as per approved drawing 33 kv 398 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.64 cmt ( 13 meter stp ) as per approved drawing 399 erection, testingand commissioning of lt line crossing by 11 kv lines on stp 11 mtr with cradle guarding ( complete work in all respect ) 400 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 401 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 402 11 kv cross arm holding clamps with bolts & nuts 403 11 kv pin insulator polymer type as per ts 404 f bracket for 11 kv line 405 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 406 turn buckle 407 g.i. wire 6 swg 408 g.i. wire 8 swg 409 g.i. wire no. 16 swg for binding 410 eye bolt 411 armour rod with ferrules for acsr rabbit / weasel helical performed 412 stone pad ( 300x300x75mm ) 413 11 kv danger board with clamp and nuts & bolts 414 11 kv number plate with clamp and nuts & bolts 415 g.i. barbed wire 416 red oxide paint 417 aluminium paint 418 aluminium binding wire 6 swg 419 earthing coil connected with nutbolt using charchol and salt 420 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 421 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 422 ht guy insulator 423 gi stay wire 7 / 8 swg 424 ht stay clamp as per approved drawing 11 kv 425 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 426 erection, testingand commissioning of ug cable 11 kv line ( complete work in all respect ) 427 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 428 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 429 cable jointing kit straight through ( 3x185 ) 430 gi pipe 6 diameter with clamps 431 cable route marker 432 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 433 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 434 gi angle iron 50x50x6 mm bracing with 4 clamps 435 m.s. top channel 100x50x6 mm., 2240 mmlong 436 clamp for top channel with nut bolt 437 g.i. barbed wire 438 stone pad ( 300x300x75mm ) 439 11 kv pin insulator polymer type as per ts 440 11 kv disc. insulators b&s type 45 kn ( polymer type ) 441 11 kv disc fitting b & s type ( 45 kn ) 442 pg clamp for rabbit 443 e bracket for 11 kv line 444 11 kv danger board with clamp and nuts & bolts 445 aluminium paint 446 red oxide paint 447 earthing coil connected with nutbolt using charchol and salt 448 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 449 ht guy insulator 450 gi stay wire 7 / 10 swg 451 ht stay clamp as per approved drawing 11 kv 452 road restoration chages forroad crossing 453 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 454 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 25 kva , 63 kva and 100 kva ( complete work in all respect ) 455 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 456 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 457 stone pad ( 300x300x75mm ) 458 clamps for lt t off with bolts & nuts 459 holding clamps for top channel, gi channel & gi angle with bolts & nuts 460 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 461 m.s. top channel 125x65x6 mm., 2240 mmlong 462 11 kv disc. insulators b&s type 45 kn ( polymer type ) 463 11 kv disc fitting b & s type ( 45 kn ) 464 tee off channel 100x50x1300 mm with clamp, nut & bolt 465 11 kv pin insulator polymer type as per ts 466 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 467 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 468 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 469 11kv tpmo with fixing clamps 470 11kv fuse set ( drop out ) with clamps 471 9 kv la , 5 ka ( distribution class ) 472 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 473 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 474 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 475 lt pvc cable 4x16 sq mm 476 lt pvc cable 3.5x70 sq mm 477 lt pvc cable 3.5x150 sq mm 478 11 kv danger board with clamp and nuts & bolts 479 g.i. barbed wire 480 acsr rabbit conductor jumpering works 481 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 482 ht guy insulator 483 gi stay wire 7 / 10 swg 484 ht stay clamp as per approved drawing 11 kv 485 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 486 gi flat 25x3 for earthing 487 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 488 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 10 kva and 16 kva ( complete work in all respect ) 489 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 490 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 491 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 492 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 493 clamps for dist. box ( 40x6 mm ) 494 clamps for t / f ( 75x8 mm gi flat ) . 495 acsr weasel conductor jumpering works 496 11 kv pin insulator polymer type as per ts 497 eye bolt 498 l.t. pvc cable 10 sq. mm single core 499 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 500 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 501 ht guy insulator 502 gi stay wire 7 / 10 swg 503 ht stay clamp as per approved drawing 11 kv 504 relocation , testing and commissioningof 250 kva , 11 / 0.433 kv three phase transformer sub station ( complete work in all respect ) 505 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 506 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 507 stone pad ( 300x300x75mm ) 508 holding clamps for top channel, gi channel & gi angle with bolts & nuts 509 m.s. top channel 125x65x6 mm., 2240 mmlong 510 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 511 gi channel 75x75x6 mm &bolt and nut ( t / f base support ) 512 11 kv disc. insulators b&s type 45 kn ( polymer type ) 513 11 kv disc fitting b & s type ( 45 kn ) 514 tee off channel 100x50x1300 mm with clamp, nut & bolt 515 clamps for lt t off with bolts & nuts 516 11 kv pin insulator polymer type as per ts 517 11kv tpmo with fixing clamps 518 11kv fuse set ( drop out ) with clamps 519 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 520 copper l piece 50x225x10mm 521 copper l piece 50x225x12mm 522 lt pvc cable 3.5x400 sq mm 523 al leg long barrel off size 524 4 core lt mcb with box 525 11 kv danger board with clamp and nuts & bolts 526 g.i. barbed wire 527 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 528 ht guy insulator 529 gi stay wire 7 / 10 swg 530 ht stay clamp as per approved drawing 11 kv 531 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 532 gi flat 50x6 for earthing 533 gi channel 125x65 mm 534 9 kv la , 5 ka ( distribution class ) 535 crimping type heavy duty aluminium lugs suitable for connection pvc cables 536 pg clamp for rabbit 537 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 538 dts plinth foundation 539 dismentaling of distribution transformer along with accessories. relocate the dt only at new location , testing , comissioning and charging and other shifting to store. 540 erection, testingand commissioning of new lt line with ab cable ( complete work in all respect ) 541 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 542 stone pad ( 300x300x75mm ) 543 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 544 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 545 pole clamps with with i hook & nut & bolts for laying abc 546 dead end clamp ( insulated ) 547 suspension clamps ( insulated ) 548 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 549 insulating piercing connector ( 16 150 sq.mm ) 550 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 551 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 552 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 553 earthing coil connected with nutbolt using charchol and salt 554 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 555 lt guy insulator 556 gi stay wire 7 / 10 swg 557 lt stay clamp as per approved drawing 558 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 559 erection, testingand commissioning of 11kv line guarding ( complete work in all respect ) 560 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 561 height raising channel 100x50, 2240 mm long 562 back clamp for height raising channel holding clamps with bolts & nuts 563 g.i. wire 6 swg 564 g.i. wire 8 swg 565 turn buckle 566 eye bolt 567 g.i. wire no. 16 swg for binding 568 earthing coil connected with nutbolt using charchol and salt 569 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 570 ht guy insulator 571 gi stay wire 7 / 10 swg 572 ht stay clamp as per approved drawing 11 kv 573 erection, testingand commissioning of tee of channel ( complete work in all respect ) 574 gi channel 100x50x6 mm. 1300 mm long 575 gi channel clamp with nuts & bolts 576 11 kv disc. insulators b&s type 45 kn ( polymer type ) 577 11 kv disc fitting b & s type ( 45 kn ) 578 11 kv pin insulator polymer type as per ts 579 pg clamp for rabbit 580 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 581 ht guy insulator 582 gi stay wire 7 / 10 swg 583 ht stay clamp as per approved drawing 11 kv 584 control room building extention work ( complete work in all respect ) 585 rcc work of building with internal wiring works for extension of control room building ( 36 sqmm ) ( complete works in all respect ) as per approved drawing and specification 586 water pump, toilet works as per approved drawing and specification...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32081305 development of distribution infrastructure at kanpur zone ( electricity distribution circle edc etawah, edc auraiya, edc kannauj, edc farrukhabad, edc kanpur nagar and edc kanpur dehat ) , district etawah, auraiya, kannauj, farrukhabad, kanpur nagar andkanpur dehat of uttar pradeshstate under the revamped reforms based and results linked, distribution sector scheme 1 supply of items 2 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 3 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 4 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 5 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 6 stone pad ( 300x300x75mm ) 7 1 core ( al. ) 120mm2 lt armoured xlpe cable 8 1 core ( al. ) 95mm2 lt armoured xlpe cable 9 1 core ( al. ) 50mm2 lt armoured xlpe cable 10 1 core ( al. ) 25mm2 lt armoured xlpe cable 11 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 12 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 13 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 14 armoured service cable 2cx4 sqmm for single phase consumer 15 armoured service cable 2cx6 sqmm for single phase consumer 16 armoured service cable 4cx10 sqmm for three phase consumer 17 armoured service cable 4cx16 sqmm for three phase consumer 18 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 19 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 20 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 21 lt pvc cable 3.5x150 sq mm 22 lt pvc cable 3.5x70 sq mm 23 lt pvc cable 4x16 sq mm 24 l.t. pvc cable 10 sq. mm single core 25 lt pvc cable 3.5x400 sq mm 26 acsr rabbit conductor 27 aluminium binding wire 6 swg 28 jointing sleave 29 mid span joint 120mm2 30 acsr rabbit conductor jumpering works 31 acsr weasel conductor jumpering works 32 11 kv danger board with clamp and nuts & bolts 33 11 kv number plate with clamp and nuts & bolts 34 11kv fuse set ( drop out ) with clamps 35 11kv tpmo with fixing clamps 36 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 37 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 38 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 39 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 40 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 41 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 42 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 43 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 44 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 45 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 46 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 47 4 core lt mcb with box 48 copper l piece 50x225x10mm 49 copper l piece 50x225x12mm 50 al leg long barrel off size 51 9 kv la , 5 ka ( distribution class ) 52 9 kv la , 10 ka ( station class ) 53 earthing coil connected with nutbolt using charchol and salt 54 gi flat 50x6 for earthing 55 gi flat 25x3 for earthing 56 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 57 gi pipe 6 diameter with clamps 58 g.i. barbed wire 59 g.i. wire no. 16 swg for binding 60 g.i. wire 6 swg 61 g.i. wire 8 swg 62 33 kv g.i. pin ( 10 kn ) with nuts & washers 63 11 kv disc fitting b & s type ( 45 kn ) 64 11 kv disc. insulators b&s type 45 kn ( polymer type ) 65 11 kv pin insulator polymer type as per ts 66 33 kv pin insulator 67 lt shackle insulator 68 insulating piercing connector ( 50 150 sq.mm ) 69 insulating piercing connector ( 16 150 sq.mm ) 70 dead end clamp ( insulated ) 71 end cap for ab cable 72 suspension clamps ( insulated ) 73 pole clamps with with i hook & nut & bolts for laying abc 74 d straps 75 insulation mastic tape ( 2inc x 10 feet ) . 76 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 77 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 78 aluminium paint 79 red oxide paint 80 smart tvm meter compatible with system ( ami ) complete set 81 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 82 crimping type heavy duty aluminium lugs suitable for connection pvc cables 83 armour rod with ferrules for acsr rabbit / weasel helical performed 84 cable route marker 85 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 86 pg clamp for rabbit 87 gi stay wire 7 / 10 swg 88 gi stay wire 7 / 8 swg 89 ht guy insulator 90 lt guy insulator 91 33 kv stay complete ( gi stay rod 20x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 92 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 93 turn buckle 94 ht stay clamp as per approved drawing 33 kv 95 ht stay clamp as per approved drawing 11 kv 96 lt stay clamp as per approved drawing 97 11 kv cross arm holding clamps with bolts & nuts 98 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 99 33 kv cross arm holding clamps with bolts & nuts 100 33 kv steel x arm v type ( gi channel 100 x 50 x 6 mm ) 101 angle for vertical arml50x50x6 ( type a ) 900mm 102 angle for vertical arml50x50x6 ( type b ) 900mm 103 top clamp for vertical arm l 50x6 ( type a ) 435 mm 104 top clamp for vertical arm l 50x6 ( type b ) 435 mm 105 bottom clamp for vertical arm l 50x6 ( type a ) 507 mm 106 bottom clamp for vertical arm l 50x6 ( type b ) 507 mm 107 clamp for top channel with nut bolt 108 clamps for lt t off with bolts & nuts 109 e bracket for 11 kv line 110 eye bolt 111 f bracket for 11 kv line 112 f bracket for 33 kv line 113 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 114 holding clamps for top channel, gi channel & gi angle with bolts & nuts 115 m.s. top channel 100x50x6 mm., 2240 mmlong 116 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 117 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 118 m.s. top channel 125x65x6 mm., 2240 mmlong 119 tee off channel 100x50x1300 mm with clamp, nut & bolt 120 clamps for dist. box ( 40x6 mm ) 121 clamps for t / f ( 75x8 mm gi flat ) . 122 gi. guarding angle 75x75x6 mm 3010 mm long with clamp 123 height raising channel 100x50, 2240 mm long 124 back clamp for height raising channel holding clamps with bolts & nuts 125 gi channel 100x50x6 mm. 1300 mm long 126 gi channel clamp with nuts & bolts 127 gi angle iron 50x50x6 mm bracing with 4 clamps 128 gi channel 125x65 mm 129 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 130 gi channel 75x75x6 mm &bolt and nut ( t / f base support ) 131 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 132 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 133 cable jointing kit straight through ( 3x185 ) 134 extra prefabricated items like clamp , channel, angle with nut bolt 135 erection part 136 conversion of existing service cable to new armoured service cable with all required accessories like j pipe , shaddle , conduit pipe , clamp , gi wire , reel insulator , earthing bolt and lugs etc. ( complete work in all respect ) and removing and shifting of existing material to client store 137 armoured service cable 2cx4 sqmm for single phase consumer 138 armoured service cable 2cx6 sqmm for single phase consumer 139 armoured service cable 4cx10 sqmm for three phase consumer 140 armoured service cable 4cx16 sqmm for three phase consumer 141 erection, testingand commissioning of replacement oflt bare conductor with ab cables ( complete work in all respect ) 142 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 143 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 144 stone pad ( 300x300x75mm ) 145 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 146 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 147 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 148 pole clamps with with i hook & nut & bolts for laying abc 149 dead end clamp ( insulated ) 150 suspension clamps ( insulated ) 151 insulating piercing connector ( 16 150 sq.mm ) 152 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 153 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 154 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 155 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 156 earthing coil connected with nutbolt using charchol and salt 157 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 158 lt guy insulator 159 gi stay wire 7 / 10 swg 160 lt stay clamp as per approved drawing 161 removing and shifting of existing material to client store 162 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 163 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 164 erection, testingand commissioning of replacement ofab cable ( damage ) with ab cables ( complete work in all respect ) 165 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 166 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 167 stone pad ( 300x300x75mm ) 168 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 169 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 170 pole clamps with with i hook & nut & bolts for laying abc 171 dead end clamp ( insulated ) 172 suspension clamps ( insulated ) 173 insulating piercing connector ( 16 150 sq.mm ) 174 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 175 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 176 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 177 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 178 earthing coil connected with nutbolt using charchol and salt 179 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 180 lt guy insulator 181 gi stay wire 7 / 10 swg 182 lt stay clamp as per approved drawing 183 removing and shifting of existing material to client store 184 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 185 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 186 erection, testingand commissioning of replacement of lt line with xlpe armoured cables ( complete work in all respect ) 187 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 188 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 189 stone pad ( 300x300x75mm ) 190 angle for vertical arml50x50x6 ( type a ) 900mm 191 top clamp for vertical arm l 50x6 ( type a ) 435 mm 192 bottom clamp for vertical arm l 50x6 ( type a ) 507 mm 193 angle for vertical arml50x50x6 ( type b ) 900mm 194 top clamp for vertical arm l 50x6 ( type b ) 435 mm 195 bottom clamp for vertical arm l 50x6 ( type b ) 507 mm 196 lt shackle insulator 197 d straps 198 1 core ( al. ) 120mm2 lt armoured xlpe cable 199 1 core ( al. ) 95mm2 lt armoured xlpe cable 200 1 core ( al. ) 50mm2 lt armoured xlpe cable 201 1 core ( al. ) 25mm2 lt armoured xlpe cable 202 mid span joint 120mm2 203 insulating piercing connector ( 50 150 sq.mm ) 204 insulation mastic tape ( 2inc x 10 feet ) . 205 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 206 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 207 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 208 earthing coil connected with nutbolt using charchol and salt 209 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 210 lt guy insulator 211 gi stay wire 7 / 10 swg 212 lt stay clamp as per approved drawing 213 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 214 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 215 removing and shifting of existing material to client store 216 survey , erection, testingand commissioning of 11 kv line ( feeder spliting due to over loading ) on 8.5 mtr pcc pole 115.6 ckm and 11 mtr stp pole 151.4 ckm ( complete work in all respect ) 217 route survey and pole spotting for 11 kv line 218 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 219 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 220 acsr rabbit conductor 221 stone pad ( 300x300x75mm ) 222 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 223 11 kv cross arm holding clamps with bolts & nuts 224 f bracket for 11 kv line 225 m.s. top channel 100x50x6 mm., 2240 mmlong 226 clamp for top channel with nut bolt 227 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 228 e bracket for 11 kv line 229 11 kv pin insulator polymer type as per ts 230 11 kv disc. insulators b&s type 45 kn ( polymer type ) 231 11 kv disc fitting b & s type ( 45 kn ) 232 pg clamp for rabbit 233 aluminium binding wire 6 swg 234 jointing sleave 235 11 kv danger board with clamp and nuts & bolts 236 g.i. barbed wire 237 aluminium paint 238 red oxide paint 239 earthing coil connected with nutbolt using charchol and salt 240 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 241 ht guy insulator 242 gi stay wire 7 / 10 swg 243 ht stay clamp as per approved drawing 11 kv 244 11 kv number plate with clamp and nuts & bolts 245 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 246 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 247 erection, testingand commissioning of 11 kv vcb with complete assoceries as apporoved drawing and tecchanical specifiactions ( complete work in all respect ) 248 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 249 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 250 smart tvm meter compatible with system ( ami ) complete set 251 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 252 gi flat 50x6 for earthing 253 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 254 stone pad ( 300x300x75mm ) 255 m.s. top channel 100x50x6 mm., 2240 mmlong 256 clamp for top channel with nut bolt 257 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 258 11 kv disc. insulators b&s type 45 kn ( polymer type ) 259 11 kv disc fitting b & s type ( 45 kn ) 260 pg clamp for rabbit 261 11 kv danger board with clamp and nuts & bolts 262 g.i. barbed wire 263 earthing coil connected with nutbolt using charchol and salt 264 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 265 ht guy insulator 266 gi stay wire 7 / 10 swg 267 ht stay clamp as per approved drawing 11 kv 268 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 269 survey , erection, testingand commissioning of 11 kv line ( feeder sagrigation ) ( complete work in all respect ) 270 route survey and pole spotting for 11 kv line 271 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 272 acsr rabbit conductor 273 stone pad ( 300x300x75mm ) 274 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 275 11 kv cross arm holding clamps with bolts & nuts 276 f bracket for 11 kv line 277 m.s. top channel 100x50x6 mm., 2240 mmlong 278 clamp for top channel with nut bolt 279 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 280 e bracket for 11 kv line 281 11 kv pin insulator polymer type as per ts 282 11 kv disc. insulators b&s type 45 kn ( polymer type ) 283 11 kv disc fitting b & s type ( 45 kn ) 284 pg clamp for rabbit 285 aluminium binding wire 6 swg 286 jointing sleave 287 11 kv danger board with clamp and nuts & bolts 288 g.i. barbed wire 289 earthing coil connected with nutbolt using charchol and salt 290 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 291 ht guy insulator 292 gi stay wire 7 / 10 swg 293 ht stay clamp as per approved drawing 11 kv 294 11 kv number plate with clamp and nuts & bolts 295 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 296 erection, testingand commissioning of 11 kv vcb with complete assoceries as apporoved drawing and tecchanical specifiactions ( feeder segrigation ) ( complete work in all respect ) 297 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 298 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 299 smart tvm meter compatible with system ( ami ) complete set 300 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 301 gi flat 50x6 for earthing 302 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 303 stone pad ( 300x300x75mm ) 304 m.s. top channel 100x50x6 mm., 2240 mmlong 305 clamp for top channel with nut bolt 306 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 307 11 kv disc. insulators b&s type 45 kn ( polymer type ) 308 11 kv disc fitting b & s type ( 45 kn ) 309 pg clamp for rabbit 310 11 kv danger board with clamp and nuts & bolts 311 g.i. barbed wire 312 earthing coil connected with nutbolt using charchol and salt 313 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 314 ht guy insulator 315 gi stay wire 7 / 10 swg 316 ht stay clamp as per approved drawing 11 kv 317 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 318 erection, testingand commissioning of 11 kv nh crossing ( complete work in all respect ) 319 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 320 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 321 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 322 gi pipe 6 diameter with clamps 323 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 324 gi angle iron 50x50x6 mm bracing with 4 clamps 325 m.s. top channel 100x50x6 mm., 2240 mmlong 326 clamp for top channel with nut bolt 327 g.i. barbed wire 328 stone pad ( 300x300x75mm ) 329 11 kv pin insulator polymer type as per ts 330 11 kv disc. insulators b&s type 45 kn ( polymer type ) 331 11 kv disc fitting b & s type ( 45 kn ) 332 pg clamp for rabbit 333 e bracket for 11 kv line 334 11 kv danger board with clamp and nuts & bolts 335 aluminium paint 336 red oxide paint 337 earthing coil connected with nutbolt using charchol and salt 338 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 339 ht guy insulator 340 gi stay wire 7 / 10 swg 341 ht stay clamp as per approved drawing 11 kv 342 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 343 cable laying including cost of material eg. , bricks, sand, clamps etc. 344 erection, testingand commissioning of 11 kv railway crossing ( complete work in all respect ) 345 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 346 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 347 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 348 gi pipe 6 diameter with clamps 349 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 350 gi angle iron 50x50x6 mm bracing with 4 clamps 351 m.s. top channel 100x50x6 mm., 2240 mmlong 352 clamp for top channel with nut bolt 353 g.i. barbed wire 354 stone pad ( 300x300x75mm ) 355 11 kv pin insulator polymer type as per ts 356 11 kv disc. insulators b&s type 45 kn ( polymer type ) 357 11 kv disc fitting b & s type ( 45 kn ) 358 pg clamp for rabbit 359 e bracket for 11 kv line 360 11 kv danger board with clamp and nuts & bolts 361 aluminium paint 362 red oxide paint 363 earthing coil connected with nutbolt using charchol and salt 364 9 kv la , 10 ka ( station class ) 365 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 366 ht guy insulator 367 gi stay wire 7 / 10 swg 368 ht stay clamp as per approved drawing 11 kv 369 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 370 cable laying including cost of material eg. , bricks, sand, clamps etc. 371 erection, testingand commissioning of 11 kv line crossing by 33kv lines on stp 13 mtr with cradle guarding ( complete work in all respect ) 372 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 373 33 kv steel x arm v type ( gi channel 100 x 50 x 6 mm ) 374 33 kv cross arm holding clamps with bolts & nuts 375 33 kv pin insulator 376 33 kv g.i. pin ( 10 kn ) with nuts & washers 377 gi. guarding angle 75x75x6 mm 3010 mm long with clamp 378 f bracket for 33 kv line 379 turn buckle 380 g.i. wire 6 swg 381 g.i. wire 8 swg 382 g.i. wire no. 16 swg for binding 383 eye bolt 384 armour rod with ferrules for acsr rabbit / weasel helical performed 385 stone pad ( 300x300x75mm ) 386 11 kv danger board with clamp and nuts & bolts 387 11 kv number plate with clamp and nuts & bolts 388 g.i. barbed wire 389 red oxide paint 390 aluminium paint 391 aluminium binding wire 6 swg 392 earthing coil connected with nutbolt using charchol and salt 393 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 394 33 kv stay complete ( gi stay rod 20x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 395 ht guy insulator 396 gi stay wire 7 / 8 swg 397 ht stay clamp as per approved drawing 33 kv 398 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.64 cmt ( 13 meter stp ) as per approved drawing 399 erection, testingand commissioning of lt line crossing by 11 kv lines on stp 11 mtr with cradle guarding ( complete work in all respect ) 400 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 401 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 402 11 kv cross arm holding clamps with bolts & nuts 403 11 kv pin insulator polymer type as per ts 404 f bracket for 11 kv line 405 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 406 turn buckle 407 g.i. wire 6 swg 408 g.i. wire 8 swg 409 g.i. wire no. 16 swg for binding 410 eye bolt 411 armour rod with ferrules for acsr rabbit / weasel helical performed 412 stone pad ( 300x300x75mm ) 413 11 kv danger board with clamp and nuts & bolts 414 11 kv number plate with clamp and nuts & bolts 415 g.i. barbed wire 416 red oxide paint 417 aluminium paint 418 aluminium binding wire 6 swg 419 earthing coil connected with nutbolt using charchol and salt 420 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 421 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 422 ht guy insulator 423 gi stay wire 7 / 8 swg 424 ht stay clamp as per approved drawing 11 kv 425 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 426 erection, testingand commissioning of ug cable 11 kv line ( complete work in all respect ) 427 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 428 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 429 cable jointing kit straight through ( 3x185 ) 430 gi pipe 6 diameter with clamps 431 cable route marker 432 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 433 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 434 gi angle iron 50x50x6 mm bracing with 4 clamps 435 m.s. top channel 100x50x6 mm., 2240 mmlong 436 clamp for top channel with nut bolt 437 g.i. barbed wire 438 stone pad ( 300x300x75mm ) 439 11 kv pin insulator polymer type as per ts 440 11 kv disc. insulators b&s type 45 kn ( polymer type ) 441 11 kv disc fitting b & s type ( 45 kn ) 442 pg clamp for rabbit 443 e bracket for 11 kv line 444 11 kv danger board with clamp and nuts & bolts 445 aluminium paint 446 red oxide paint 447 earthing coil connected with nutbolt using charchol and salt 448 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 449 ht guy insulator 450 gi stay wire 7 / 10 swg 451 ht stay clamp as per approved drawing 11 kv 452 road restoration chages forroad crossing 453 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 454 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 25 kva , 63 kva and 100 kva ( complete work in all respect ) 455 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 456 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 457 stone pad ( 300x300x75mm ) 458 clamps for lt t off with bolts & nuts 459 holding clamps for top channel, gi channel & gi angle with bolts & nuts 460 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 461 m.s. top channel 125x65x6 mm., 2240 mmlong 462 11 kv disc. insulators b&s type 45 kn ( polymer type ) 463 11 kv disc fitting b & s type ( 45 kn ) 464 tee off channel 100x50x1300 mm with clamp, nut & bolt 465 11 kv pin insulator polymer type as per ts 466 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 467 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 468 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 469 11kv tpmo with fixing clamps 470 11kv fuse set ( drop out ) with clamps 471 9 kv la , 5 ka ( distribution class ) 472 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 473 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 474 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 475 lt pvc cable 4x16 sq mm 476 lt pvc cable 3.5x70 sq mm 477 lt pvc cable 3.5x150 sq mm 478 11 kv danger board with clamp and nuts & bolts 479 g.i. barbed wire 480 acsr rabbit conductor jumpering works 481 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 482 ht guy insulator 483 gi stay wire 7 / 10 swg 484 ht stay clamp as per approved drawing 11 kv 485 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 486 gi flat 25x3 for earthing 487 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 488 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 10 kva and 16 kva ( complete work in all respect ) 489 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 490 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 491 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 492 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 493 clamps for dist. box ( 40x6 mm ) 494 clamps for t / f ( 75x8 mm gi flat ) . 495 acsr weasel conductor jumpering works 496 11 kv pin insulator polymer type as per ts 497 eye bolt 498 l.t. pvc cable 10 sq. mm single core 499 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 500 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 501 ht guy insulator 502 gi stay wire 7 / 10 swg 503 ht stay clamp as per approved drawing 11 kv 504 relocation , testing and commissioningof 250 kva , 11 / 0.433 kv three phase transformer sub station ( complete work in all respect ) 505 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 506 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 507 stone pad ( 300x300x75mm ) 508 holding clamps for top channel, gi channel & gi angle with bolts & nuts 509 m.s. top channel 125x65x6 mm., 2240 mmlong 510 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 511 gi channel 75x75x6 mm &bolt and nut ( t / f base support ) 512 11 kv disc. insulators b&s type 45 kn ( polymer type ) 513 11 kv disc fitting b & s type ( 45 kn ) 514 tee off channel 100x50x1300 mm with clamp, nut & bolt 515 clamps for lt t off with bolts & nuts 516 11 kv pin insulator polymer type as per ts 517 11kv tpmo with fixing clamps 518 11kv fuse set ( drop out ) with clamps 519 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 520 copper l piece 50x225x10mm 521 copper l piece 50x225x12mm 522 lt pvc cable 3.5x400 sq mm 523 al leg long barrel off size 524 4 core lt mcb with box 525 11 kv danger board with clamp and nuts & bolts 526 g.i. barbed wire 527 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 528 ht guy insulator 529 gi stay wire 7 / 10 swg 530 ht stay clamp as per approved drawing 11 kv 531 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 532 gi flat 50x6 for earthing 533 gi channel 125x65 mm 534 9 kv la , 5 ka ( distribution class ) 535 crimping type heavy duty aluminium lugs suitable for connection pvc cables 536 pg clamp for rabbit 537 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 538 dts plinth foundation 539 dismentaling of distribution transformer along with accessories. relocate the dt only at new location , testing , comissioning and charging and other shifting to store. 540 erection, testingand commissioning of new lt line with ab cable ( complete work in all respect ) 541 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 542 stone pad ( 300x300x75mm ) 543 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 544 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 545 pole clamps with with i hook & nut & bolts for laying abc 546 dead end clamp ( insulated ) 547 suspension clamps ( insulated ) 548 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 549 insulating piercing connector ( 16 150 sq.mm ) 550 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 551 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 552 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 553 earthing coil connected with nutbolt using charchol and salt 554 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 555 lt guy insulator 556 gi stay wire 7 / 10 swg 557 lt stay clamp as per approved drawing 558 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 559 erection, testingand commissioning of 11kv line guarding ( complete work in all respect ) 560 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 561 height raising channel 100x50, 2240 mm long 562 back clamp for height raising channel holding clamps with bolts & nuts 563 g.i. wire 6 swg 564 g.i. wire 8 swg 565 turn buckle 566 eye bolt 567 g.i. wire no. 16 swg for binding 568 earthing coil connected with nutbolt using charchol and salt 569 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 570 ht guy insulator 571 gi stay wire 7 / 10 swg 572 ht stay clamp as per approved drawing 11 kv 573 erection, testingand commissioning of tee of channel ( complete work in all respect ) 574 gi channel 100x50x6 mm. 1300 mm long 575 gi channel clamp with nuts & bolts 576 11 kv disc. insulators b&s type 45 kn ( polymer type ) 577 11 kv disc fitting b & s type ( 45 kn ) 578 11 kv pin insulator polymer type as per ts 579 pg clamp for rabbit 580 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 581 ht guy insulator 582 gi stay wire 7 / 10 swg 583 ht stay clamp as per approved drawing 11 kv 584 control room building extention work ( complete work in all respect ) 585 rcc work of building with internal wiring works for extension of control room building ( 36 sqmm ) ( complete works in all respect ) as per approved drawing and specification 586 water pump, toilet works as per approved drawing and specification...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32081283 development of distribution infrastructure at agra 2 zone ( electricity distribution circle edc agra, edc mathura i, edc mathura ii and eudc mathura ) , district agra & mathuraofuttar pradeshstate under the revamped reforms based and results linked, distribution sector scheme 2 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 3 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 4 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 5 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 6 stone pad ( 300x300x75mm ) 7 1 core ( al. ) 120mm2 lt armoured xlpe cable 8 1 core ( al. ) 95mm2 lt armoured xlpe cable 9 1 core ( al. ) 50mm2 lt armoured xlpe cable 10 1 core ( al. ) 25mm2 lt armoured xlpe cable 11 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 12 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 13 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 14 armoured service cable 2cx4 sqmm for single phase consumer 15 armoured service cable 2cx6 sqmm for single phase consumer 16 armoured service cable 4cx10 sqmm for three phase consumer 17 armoured service cable 4cx16 sqmm for three phase consumer 18 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 19 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 20 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 21 lt pvc cable 3.5x150 sq mm 22 lt pvc cable 3.5x70 sq mm 23 lt pvc cable 4x16 sq mm 24 l.t. pvc cable 10 sq. mm single core 25 lt pvc cable 3.5x400 sq mm 26 acsr rabbit conductor 27 aluminium binding wire 6 swg 28 jointing sleave 29 mid span joint 120mm2 30 acsr rabbit conductor jumpering works 31 acsr weasel conductor jumpering works 32 11 kv danger board with clamp and nuts & bolts 33 11 kv number plate with clamp and nuts & bolts 34 11kv fuse set ( drop out ) with clamps 35 11kv tpmo with fixing clamps 36 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 37 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 38 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 39 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 40 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 41 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 42 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 43 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 44 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 45 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 46 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 47 4 core lt mcb with box 48 copper l piece 50x225x10mm 49 copper l piece 50x225x12mm 50 al leg long barrel off size 51 9 kv la , 5 ka ( distribution class ) 52 9 kv la , 10 ka ( station class ) 53 earthing coil connected with nutbolt using charchol and salt 54 gi flat 50x6 for earthing 55 gi flat 25x3 for earthing 56 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 57 gi pipe 6 diameter with clamps 58 g.i. barbed wire 59 g.i. wire no. 16 swg for binding 60 g.i. wire 6 swg 61 g.i. wire 8 swg 62 33 kv g.i. pin ( 10 kn ) with nuts & washers 63 11 kv disc fitting b & s type ( 45 kn ) 64 11 kv disc. insulators b&s type 45 kn ( polymer type ) 65 11 kv pin insulator polymer type as per ts 66 33 kv pin insulator 67 lt shackle insulator 68 insulating piercing connector ( 50 150 sq.mm ) 69 insulating piercing connector ( 16 150 sq.mm ) 70 dead end clamp ( insulated ) 71 end cap for ab cable 72 suspension clamps ( insulated ) 73 pole clamps with with i hook & nut & bolts for laying abc 74 d straps 75 insulation mastic tape ( 2inc x 10 feet ) . 76 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 77 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 78 aluminium paint 79 red oxide paint 80 smart tvm meter compatible with system ( ami ) complete set 81 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 82 crimping type heavy duty aluminium lugs suitable for connection pvc cables 83 armour rod with ferrules for acsr rabbit / weasel helical performed 84 cable route marker 85 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 86 pg clamp for rabbit 87 gi stay wire 7 / 10 swg 88 gi stay wire 7 / 8 swg 89 ht guy insulator 90 lt guy insulator 91 33 kv stay complete ( gi stay rod 20x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 92 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 93 turn buckle 94 ht stay clamp as per approved drawing 33 kv 95 ht stay clamp as per approved drawing 11 kv 96 lt stay clamp as per approved drawing 97 11 kv cross arm holding clamps with bolts & nuts 98 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 99 33 kv cross arm holding clamps with bolts & nuts 100 33 kv steel x arm v type ( gi channel 100 x 50 x 6 mm ) 101 angle for vertical arml50x50x6 ( type a ) 900mm 102 angle for vertical arml50x50x6 ( type b ) 900mm 103 top clamp for vertical arm l 50x6 ( type a ) 435 mm 104 top clamp for vertical arm l 50x6 ( type b ) 435 mm 105 bottom clamp for vertical arm l 50x6 ( type a ) 507 mm 106 bottom clamp for vertical arm l 50x6 ( type b ) 507 mm 107 clamp for top channel with nut bolt 108 clamps for lt t off with bolts & nuts 109 e bracket for 11 kv line 110 eye bolt 111 f bracket for 11 kv line 112 f bracket for 33 kv line 113 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 114 holding clamps for top channel, gi channel & gi angle with bolts & nuts 115 m.s. top channel 100x50x6 mm., 2240 mmlong 116 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 117 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 118 m.s. top channel 125x65x6 mm., 2240 mmlong 119 tee off channel 100x50x1300 mm with clamp, nut & bolt 120 clamps for dist. box ( 40x6 mm ) 121 clamps for t / f ( 75x8 mm gi flat ) . 122 gi. guarding angle 75x75x6 mm 3010 mm long with clamp 123 height raising channel 100x50, 2240 mm long 124 back clamp for height raising channel holding clamps with bolts & nuts 125 gi channel 100x50x6 mm. 1300 mm long 126 gi channel clamp with nuts & bolts 127 gi angle iron 50x50x6 mm bracing with 4 clamps 128 gi channel 125x65 mm 129 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 130 gi channel 75x75x6 mm &bolt and nut ( t / f base support ) 131 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 132 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 133 cable jointing kit straight through ( 3x185 ) 134 extra prefabricated items like clamp , channel, angle with nut bolt 135 erection part 136 conversion of existing service cable to new armoured service cable with all required accessories like j pipe , shaddle , conduit pipe , clamp , gi wire , reel insulator , earthing bolt and lugs etc. ( complete work in all respect ) and removing and shifting of existing material to client store 137 armoured service cable 2cx4 sqmm for single phase consumer 138 armoured service cable 2cx6 sqmm for single phase consumer 139 armoured service cable 4cx10 sqmm for three phase consumer 140 armoured service cable 4cx16 sqmm for three phase consumer 141 erection, testingand commissioning of replacement oflt bare conductor with ab cables ( complete work in all respect ) 142 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 143 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 144 stone pad ( 300x300x75mm ) 145 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 146 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 147 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 148 pole clamps with with i hook & nut & bolts for laying abc 149 dead end clamp ( insulated ) 150 suspension clamps ( insulated ) 151 insulating piercing connector ( 16 150 sq.mm ) 152 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 153 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 154 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 155 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 156 earthing coil connected with nutbolt using charchol and salt 157 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 158 lt guy insulator 159 gi stay wire 7 / 10 swg 160 lt stay clamp as per approved drawing 161 removing and shifting of existing material to client store 162 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 163 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 164 erection, testingand commissioning of replacement ofab cable ( damage ) with ab cables ( complete work in all respect ) 165 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 166 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 167 stone pad ( 300x300x75mm ) 168 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 169 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 170 pole clamps with with i hook & nut & bolts for laying abc 171 dead end clamp ( insulated ) 172 suspension clamps ( insulated ) 173 insulating piercing connector ( 16 150 sq.mm ) 174 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 175 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 176 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 177 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 178 earthing coil connected with nutbolt using charchol and salt 179 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 180 lt guy insulator 181 gi stay wire 7 / 10 swg 182 lt stay clamp as per approved drawing 183 removing and shifting of existing material to client store 184 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 185 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 186 erection, testingand commissioning of replacement of lt line with xlpe armoured cables ( complete work in all respect ) 187 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 188 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 189 stone pad ( 300x300x75mm ) 190 angle for vertical arml50x50x6 ( type a ) 900mm 191 top clamp for vertical arm l 50x6 ( type a ) 435 mm 192 bottom clamp for vertical arm l 50x6 ( type a ) 507 mm 193 angle for vertical arml50x50x6 ( type b ) 900mm 194 top clamp for vertical arm l 50x6 ( type b ) 435 mm 195 bottom clamp for vertical arm l 50x6 ( type b ) 507 mm 196 lt shackle insulator 197 d straps 198 1 core ( al. ) 120mm2 lt armoured xlpe cable 199 1 core ( al. ) 95mm2 lt armoured xlpe cable 200 1 core ( al. ) 50mm2 lt armoured xlpe cable 201 1 core ( al. ) 25mm2 lt armoured xlpe cable 202 mid span joint 120mm2 203 insulating piercing connector ( 50 150 sq.mm ) 204 insulation mastic tape ( 2inc x 10 feet ) . 205 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 206 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 207 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 208 earthing coil connected with nutbolt using charchol and salt 209 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 210 lt guy insulator 211 gi stay wire 7 / 10 swg 212 lt stay clamp as per approved drawing 213 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 214 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.39 cmt ( 9 meter stp ) as per approved drawing 215 removing and shifting of existing material to client store 216 survey , erection, testingand commissioning of 11 kv line ( feeder spliting due to over loading ) on 8.5 mtr pcc pole 115.6 ckm and 11 mtr stp pole 151.4 ckm ( complete work in all respect ) 217 route survey and pole spotting for 11 kv line 218 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 219 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 220 acsr rabbit conductor 221 stone pad ( 300x300x75mm ) 222 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 223 11 kv cross arm holding clamps with bolts & nuts 224 f bracket for 11 kv line 225 m.s. top channel 100x50x6 mm., 2240 mmlong 226 clamp for top channel with nut bolt 227 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 228 e bracket for 11 kv line 229 11 kv pin insulator polymer type as per ts 230 11 kv disc. insulators b&s type 45 kn ( polymer type ) 231 11 kv disc fitting b & s type ( 45 kn ) 232 pg clamp for rabbit 233 aluminium binding wire 6 swg 234 jointing sleave 235 11 kv danger board with clamp and nuts & bolts 236 g.i. barbed wire 237 aluminium paint 238 red oxide paint 239 earthing coil connected with nutbolt using charchol and salt 240 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 241 ht guy insulator 242 gi stay wire 7 / 10 swg 243 ht stay clamp as per approved drawing 11 kv 244 11 kv number plate with clamp and nuts & bolts 245 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 246 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 247 erection, testingand commissioning of 11 kv vcb with complete assoceries as apporoved drawing and tecchanical specifiactions ( complete work in all respect ) 248 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 249 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 250 smart tvm meter compatible with system ( ami ) complete set 251 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 252 gi flat 50x6 for earthing 253 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 254 stone pad ( 300x300x75mm ) 255 m.s. top channel 100x50x6 mm., 2240 mmlong 256 clamp for top channel with nut bolt 257 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 258 11 kv disc. insulators b&s type 45 kn ( polymer type ) 259 11 kv disc fitting b & s type ( 45 kn ) 260 pg clamp for rabbit 261 11 kv danger board with clamp and nuts & bolts 262 g.i. barbed wire 263 earthing coil connected with nutbolt using charchol and salt 264 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 265 ht guy insulator 266 gi stay wire 7 / 10 swg 267 ht stay clamp as per approved drawing 11 kv 268 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 269 survey , erection, testingand commissioning of 11 kv line ( feeder sagrigation ) ( complete work in all respect ) 270 route survey and pole spotting for 11 kv line 271 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 272 acsr rabbit conductor 273 stone pad ( 300x300x75mm ) 274 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 275 11 kv cross arm holding clamps with bolts & nuts 276 f bracket for 11 kv line 277 m.s. top channel 100x50x6 mm., 2240 mmlong 278 clamp for top channel with nut bolt 279 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 280 e bracket for 11 kv line 281 11 kv pin insulator polymer type as per ts 282 11 kv disc. insulators b&s type 45 kn ( polymer type ) 283 11 kv disc fitting b & s type ( 45 kn ) 284 pg clamp for rabbit 285 aluminium binding wire 6 swg 286 jointing sleave 287 11 kv danger board with clamp and nuts & bolts 288 g.i. barbed wire 289 earthing coil connected with nutbolt using charchol and salt 290 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 291 ht guy insulator 292 gi stay wire 7 / 10 swg 293 ht stay clamp as per approved drawing 11 kv 294 11 kv number plate with clamp and nuts & bolts 295 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 296 erection, testingand commissioning of 11 kv vcb with complete assoceries as apporoved drawing and tecchanical specifiactions ( feeder segrigation ) ( complete work in all respect ) 297 11 kv, 1250 a outgoing vcb indoor type with ctr 200 / 100 / 5 5a 350 mva ( compatible with existing vcb at 33 / 11 kv substation ) 298 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 299 smart tvm meter compatible with system ( ami ) complete set 300 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 301 gi flat 50x6 for earthing 302 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 303 stone pad ( 300x300x75mm ) 304 m.s. top channel 100x50x6 mm., 2240 mmlong 305 clamp for top channel with nut bolt 306 gi angle iron 65x65x6mm, 2700 mm long bracing with 4 clamps 307 11 kv disc. insulators b&s type 45 kn ( polymer type ) 308 11 kv disc fitting b & s type ( 45 kn ) 309 pg clamp for rabbit 310 11 kv danger board with clamp and nuts & bolts 311 g.i. barbed wire 312 earthing coil connected with nutbolt using charchol and salt 313 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 314 ht guy insulator 315 gi stay wire 7 / 10 swg 316 ht stay clamp as per approved drawing 11 kv 317 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 318 erection, testingand commissioning of 11 kv nh crossing ( complete work in all respect ) 319 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 320 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 321 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 322 gi pipe 6 diameter with clamps 323 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 324 gi angle iron 50x50x6 mm bracing with 4 clamps 325 m.s. top channel 100x50x6 mm., 2240 mmlong 326 clamp for top channel with nut bolt 327 g.i. barbed wire 328 stone pad ( 300x300x75mm ) 329 11 kv pin insulator polymer type as per ts 330 11 kv disc. insulators b&s type 45 kn ( polymer type ) 331 11 kv disc fitting b & s type ( 45 kn ) 332 pg clamp for rabbit 333 e bracket for 11 kv line 334 11 kv danger board with clamp and nuts & bolts 335 aluminium paint 336 red oxide paint 337 earthing coil connected with nutbolt using charchol and salt 338 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 339 ht guy insulator 340 gi stay wire 7 / 10 swg 341 ht stay clamp as per approved drawing 11 kv 342 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 343 cable laying including cost of material eg. , bricks, sand, clamps etc. 344 erection, testingand commissioning of 11 kv railway crossing ( complete work in all respect ) 345 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 346 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 347 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 348 gi pipe 6 diameter with clamps 349 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 350 gi angle iron 50x50x6 mm bracing with 4 clamps 351 m.s. top channel 100x50x6 mm., 2240 mmlong 352 clamp for top channel with nut bolt 353 g.i. barbed wire 354 stone pad ( 300x300x75mm ) 355 11 kv pin insulator polymer type as per ts 356 11 kv disc. insulators b&s type 45 kn ( polymer type ) 357 11 kv disc fitting b & s type ( 45 kn ) 358 pg clamp for rabbit 359 e bracket for 11 kv line 360 11 kv danger board with clamp and nuts & bolts 361 aluminium paint 362 red oxide paint 363 earthing coil connected with nutbolt using charchol and salt 364 9 kv la , 10 ka ( station class ) 365 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 366 ht guy insulator 367 gi stay wire 7 / 10 swg 368 ht stay clamp as per approved drawing 11 kv 369 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 370 cable laying including cost of material eg. , bricks, sand, clamps etc. 371 erection, testingand commissioning of 11 kv line crossing by 33kv lines on stp 13 mtr with cradle guarding ( complete work in all respect ) 372 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 373 33 kv steel x arm v type ( gi channel 100 x 50 x 6 mm ) 374 33 kv cross arm holding clamps with bolts & nuts 375 33 kv pin insulator 376 33 kv g.i. pin ( 10 kn ) with nuts & washers 377 gi. guarding angle 75x75x6 mm 3010 mm long with clamp 378 f bracket for 33 kv line 379 turn buckle 380 g.i. wire 6 swg 381 g.i. wire 8 swg 382 g.i. wire no. 16 swg for binding 383 eye bolt 384 armour rod with ferrules for acsr rabbit / weasel helical performed 385 stone pad ( 300x300x75mm ) 386 11 kv danger board with clamp and nuts & bolts 387 11 kv number plate with clamp and nuts & bolts 388 g.i. barbed wire 389 red oxide paint 390 aluminium paint 391 aluminium binding wire 6 swg 392 earthing coil connected with nutbolt using charchol and salt 393 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 394 33 kv stay complete ( gi stay rod 20x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 395 ht guy insulator 396 gi stay wire 7 / 8 swg 397 ht stay clamp as per approved drawing 33 kv 398 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.64 cmt ( 13 meter stp ) as per approved drawing 399 erection, testingand commissioning of lt line crossing by 11 kv lines on stp 11 mtr with cradle guarding ( complete work in all respect ) 400 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 401 11 kv steel x arm v type ( gi channel 65x 65 x 6 mm ) 402 11 kv cross arm holding clamps with bolts & nuts 403 11 kv pin insulator polymer type as per ts 404 f bracket for 11 kv line 405 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 406 turn buckle 407 g.i. wire 6 swg 408 g.i. wire 8 swg 409 g.i. wire no. 16 swg for binding 410 eye bolt 411 armour rod with ferrules for acsr rabbit / weasel helical performed 412 stone pad ( 300x300x75mm ) 413 11 kv danger board with clamp and nuts & bolts 414 11 kv number plate with clamp and nuts & bolts 415 g.i. barbed wire 416 red oxide paint 417 aluminium paint 418 aluminium binding wire 6 swg 419 earthing coil connected with nutbolt using charchol and salt 420 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 421 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 422 ht guy insulator 423 gi stay wire 7 / 8 swg 424 ht stay clamp as per approved drawing 11 kv 425 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 426 erection, testingand commissioning of ug cable 11 kv line ( complete work in all respect ) 427 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 428 heat shrinkable jointing kit outdoor for 11 kv 3x185 sq. mm xlpe cable 429 cable jointing kit straight through ( 3x185 ) 430 gi pipe 6 diameter with clamps 431 cable route marker 432 hdpe pipe, pn 4 pe 80 ( 160 mm dia. ) with clamp, etc 433 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 434 gi angle iron 50x50x6 mm bracing with 4 clamps 435 m.s. top channel 100x50x6 mm., 2240 mmlong 436 clamp for top channel with nut bolt 437 g.i. barbed wire 438 stone pad ( 300x300x75mm ) 439 11 kv pin insulator polymer type as per ts 440 11 kv disc. insulators b&s type 45 kn ( polymer type ) 441 11 kv disc fitting b & s type ( 45 kn ) 442 pg clamp for rabbit 443 e bracket for 11 kv line 444 11 kv danger board with clamp and nuts & bolts 445 aluminium paint 446 red oxide paint 447 earthing coil connected with nutbolt using charchol and salt 448 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 449 ht guy insulator 450 gi stay wire 7 / 10 swg 451 ht stay clamp as per approved drawing 11 kv 452 road restoration chages forroad crossing 453 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 454 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 25 kva , 63 kva and 100 kva ( complete work in all respect ) 455 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 456 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 457 stone pad ( 300x300x75mm ) 458 clamps for lt t off with bolts & nuts 459 holding clamps for top channel, gi channel & gi angle with bolts & nuts 460 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 461 m.s. top channel 125x65x6 mm., 2240 mmlong 462 11 kv disc. insulators b&s type 45 kn ( polymer type ) 463 11 kv disc fitting b & s type ( 45 kn ) 464 tee off channel 100x50x1300 mm with clamp, nut & bolt 465 11 kv pin insulator polymer type as per ts 466 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 467 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 468 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 469 11kv tpmo with fixing clamps 470 11kv fuse set ( drop out ) with clamps 471 9 kv la , 5 ka ( distribution class ) 472 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 473 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 474 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 475 lt pvc cable 4x16 sq mm 476 lt pvc cable 3.5x70 sq mm 477 lt pvc cable 3.5x150 sq mm 478 11 kv danger board with clamp and nuts & bolts 479 g.i. barbed wire 480 acsr rabbit conductor jumpering works 481 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 482 ht guy insulator 483 gi stay wire 7 / 10 swg 484 ht stay clamp as per approved drawing 11 kv 485 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 486 gi flat 25x3 for earthing 487 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 488 erection, testingand commissioningof 11 / 0.433 kv three phase transformer sub station 10 kva and 16 kva ( complete work in all respect ) 489 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 490 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 491 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 492 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 493 clamps for dist. box ( 40x6 mm ) 494 clamps for t / f ( 75x8 mm gi flat ) . 495 acsr weasel conductor jumpering works 496 11 kv pin insulator polymer type as per ts 497 eye bolt 498 l.t. pvc cable 10 sq. mm single core 499 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 500 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 501 ht guy insulator 502 gi stay wire 7 / 10 swg 503 ht stay clamp as per approved drawing 11 kv 504 relocation , testing and commissioningof 250 kva , 11 / 0.433 kv three phase transformer sub station ( complete work in all respect ) 505 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 506 gi channel 100x50x6 mm 2028 mm long ( for fuse set ) 507 stone pad ( 300x300x75mm ) 508 holding clamps for top channel, gi channel & gi angle with bolts & nuts 509 m.s. top channel 125x65x6 mm., 2240 mmlong 510 giangle 75x75x6x2028 mm with clamp &bolt and nut ( t / f base ) 511 gi channel 75x75x6 mm &bolt and nut ( t / f base support ) 512 11 kv disc. insulators b&s type 45 kn ( polymer type ) 513 11 kv disc fitting b & s type ( 45 kn ) 514 tee off channel 100x50x1300 mm with clamp, nut & bolt 515 clamps for lt t off with bolts & nuts 516 11 kv pin insulator polymer type as per ts 517 11kv tpmo with fixing clamps 518 11kv fuse set ( drop out ) with clamps 519 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 520 copper l piece 50x225x10mm 521 copper l piece 50x225x12mm 522 lt pvc cable 3.5x400 sq mm 523 al leg long barrel off size 524 4 core lt mcb with box 525 11 kv danger board with clamp and nuts & bolts 526 g.i. barbed wire 527 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 528 ht guy insulator 529 gi stay wire 7 / 10 swg 530 ht stay clamp as per approved drawing 11 kv 531 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 532 gi flat 50x6 for earthing 533 gi channel 125x65 mm 534 9 kv la , 5 ka ( distribution class ) 535 crimping type heavy duty aluminium lugs suitable for connection pvc cables 536 pg clamp for rabbit 537 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.44 cmt ( 11 meter stp ) as per approved drawing 538 dts plinth foundation 539 dismentaling of distribution transformer along with accessories. relocate the dt only at new location , testing , comissioning and charging and other shifting to store. 540 erection, testingand commissioning of new lt line with ab cable ( complete work in all respect ) 541 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 542 stone pad ( 300x300x75mm ) 543 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 544 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 545 pole clamps with with i hook & nut & bolts for laying abc 546 dead end clamp ( insulated ) 547 suspension clamps ( insulated ) 548 pg clamps 16 sq mm . 50 sq mm ( for line to line jumpering of massenger wire & energizing db neutral ) 549 insulating piercing connector ( 16 150 sq.mm ) 550 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 551 single phase distribution box with clamps ( deep drawn type ) 1 incoming and 8 outgoing 552 three phase distribution box with clamps ( deep drawn type ) 1 incoming and 4 outgoing 553 earthing coil connected with nutbolt using charchol and salt 554 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 555 lt guy insulator 556 gi stay wire 7 / 10 swg 557 lt stay clamp as per approved drawing 558 concreting works of poles using cement concreting foundation 1 part cement, 2 part sand, 4 part 20 mm size stone aggregate chips ( 1:2:4 ) 0.268 cmt ( 8.5 meter pcc pole ) as per approved drawing 559 erection, testingand commissioning of 11kv line guarding ( complete work in all respect ) 560 guarding angle 65x55x6 mm, 1.6 mtr. with clamp 561 height raising channel 100x50, 2240 mm long 562 back clamp for height raising channel holding clamps with bolts & nuts 563 g.i. wire 6 swg 564 g.i. wire 8 swg 565 turn buckle 566 eye bolt 567 g.i. wire no. 16 swg for binding 568 earthing coil connected with nutbolt using charchol and salt 569 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 570 ht guy insulator 571 gi stay wire 7 / 10 swg 572 ht stay clamp as per approved drawing 11 kv 573 erection, testingand commissioning of tee of channel ( complete work in all respect ) 574 gi channel 100x50x6 mm. 1300 mm long 575 gi channel clamp with nuts & bolts 576 11 kv disc. insulators b&s type 45 kn ( polymer type ) 577 11 kv disc fitting b & s type ( 45 kn ) 578 11 kv pin insulator polymer type as per ts 579 pg clamp for rabbit 580 stay complete ( gi stay rod 16x1800 mm, eye bolt, anchor plate, turn buckle and thimble ) bolt, nuts bolt & washers 581 ht guy insulator 582 gi stay wire 7 / 10 swg 583 ht stay clamp as per approved drawing 11 kv 584 control room building extention work ( complete work in all respect ) 585 rcc work of building with internal wiring works for extension of control room building ( 36 sqmm ) ( complete works in all respect ) as per approved drawing and specification 586 water pump, toilet works as per approved drawing and specification...

Dakshinanchal Vidyut Vitran Nigam Limited - Uttar Pradesh

32081222 development of distribution infrastructure at agra 1 zone ( electricity distribution circlesedc fatehabad edc mainpuri, edc firozabad , eudc firozabad ) , district agra, mainpuri & firozabadofuttar pradeshstate under the revamped reforms based and results linked, distribution sector scheme 1 supply of items 2 8.5 mtr.long , 180kg . pcc poles as per approved drawing and technical specification 3 9 meter long stp as per approved drawing and technical specification ( sp 33 ) 4 11 meter long stp as per approved drawing and technical specification ( sp 55 ) 5 13 meter long stp as per approved drawing and technical specification ( sp 72 ) 6 stone pad ( 300x300x75mm ) 7 1 core ( al. ) 120mm2 lt armoured xlpe cable 8 1 core ( al. ) 95mm2 lt armoured xlpe cable 9 1 core ( al. ) 50mm2 lt armoured xlpe cable 10 1 core ( al. ) 25mm2 lt armoured xlpe cable 11 11 kvxlpe cable 3x185 sq. mm. ( armoured ) 12 1x25 mm2 pvc insulated al. lt cable for energising the distribution boxes. 13 1x25 mm2 armoured xlpe insulated al. lt cable for energising the distribution boxes. 14 armoured service cable 2cx4 sqmm for single phase consumer 15 armoured service cable 2cx6 sqmm for single phase consumer 16 armoured service cable 4cx10 sqmm for three phase consumer 17 armoured service cable 4cx16 sqmm for three phase consumer 18 lt abc 3x120+1x95+1x16 sq.mm. ( bare massenger wire ) 19 lt abc 3x50+1x35+1x16 sq.mm. ( bare massenger wire ) 20 lt abc 3x95+1x70+1x16 sq.mm. ( bare massenger wire ) 21 lt pvc cable 3.5x150 sq mm 22 lt pvc cable 3.5x70 sq mm 23 lt pvc cable 4x16 sq mm 24 l.t. pvc cable 10 sq. mm single core 25 lt pvc cable 3.5x400 sq mm 26 acsr rabbit conductor 27 aluminium binding wire 6 swg 28 jointing sleave 29 mid span joint 120mm2 30 acsr rabbit conductor jumpering works 31 acsr weasel conductor jumpering works 32 11 kv danger board with clamp and nuts & bolts 33 11 kv number plate with clamp and nuts & bolts 34 11kv fuse set ( drop out ) with clamps 35 11kv tpmo with fixing clamps 36 10 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 37 16 kva, 11kv / 250 v, 1 ph transformer as bee standard ( self protected ) . 38 25 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 39 63 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 40 100 kva , 11 / 0.433 kv t / f ( bee standard 3 star rating self protected aluminium wound type ) 41 lt distribution box withmccb for protection of 10 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 42 lt distribution box withmccb for protection of 16 kva t / f and bus bar foroutgoing consumer connections and suitable to house energy meter ( without energy meter ) ( deep drawn type ) as per ts. 43 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 25kva 44 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 63 kva 45 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 100kva 46 lt incoming panel with ami metering ( smart meter compitable with system ) equipment & fixing arrangement ( as per ts ) . ( deep drawn type ) for 250kva 47 4 core lt mcb with box 48 copper l piece 50x225x10mm 49 copper l piece 50x225x12mm 50 al leg long barrel off size 51 9 kv la , 5 ka ( distribution class ) 52 9 kv la , 10 ka ( station class ) 53 earthing coil connected with nutbolt using charchol and salt 54 gi flat 50x6 for earthing 55 gi flat 25x3 for earthing 56 earthing arrangement ofchemical pipe size of 80mm , 3000 mm.long and 6 swg earthing wire etc. 57 gi pipe 6 diameter with clamps 58 g.i. barbed wire 59 g.i. wire no. 16 swg for binding 60 g.i. wire 6 swg 61 g.i. wire 8 swg 62 33 kv g.i. pin ( 10 kn ) with nuts & washers 63 11 kv disc fitting b & s type ( 45 kn ) 64 11 kv disc. insulators b&s type 45 kn ( polymer type ) 65 11 kv pin insulator polymer type as per ts 66 33 kv pin insulator 67 lt shackle insulator 68 insulating piercing connecto